The DOI matches its Crossref record; 372 of the 376 references it cites were found in a registry or an index.
Progress towards biocompatible intracortical microelectrodes for neural interfacing applications
Open accessAbstract
To ensure long-term consistent neural recordings, next-generation intracortical microelectrodes are being developed with an increased emphasis on reducing the neuro-inflammatory response. The increased emphasis stems from the improved understanding of the multifaceted role that inflammation may play in disrupting both biologic and abiologic components of the overall neural interface circuit. To combat neuro-inflammation and improve recording quality, the field is actively progressing from traditional inorganic materials towards approaches that either minimizes the microelectrode footprint or that incorporate compliant materials, bioactive molecules, conducting polymers or nanomaterials. However, the immune-privileged cortical tissue introduces an added complexity compared to other biomedical applications that remains to be fully understood. This review provides a comprehensive reflection on the current understanding of the key failure modes that may impact intracortical microelectrode performance. In addition, a detailed overview of the current status of various materials-based approaches that have gained interest for neural interfacing applications is presented, and key challenges that remain to be overcome are discussed. Finally, we present our vision on the future directions of materials-based treatments to improve intracortical microelectrodes for neural interfacing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Intracortical microelectrodes, used in applications ranging from recent advances in speech-to-text with ALS patients (Willett et al., 2023), allowing primates to play pong (Play Studio, n.d.) to clinical trials for motor deficit treatments (Gilja et al., 2015) face a decline in recording quality over time (Chestek et al., 2011; Jorfi et al., 2014; Kozai et al., 2015).”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Jorfi et al., 2014
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McCord, J. M., & Fridovich, I. (1969) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)63504-5 · Cited by 12,952
Polazzi, E., Mengoni, I., Caprini, M., Peña‐Altamira, E., Kurtys, E., & Monti, B. (2012) · Neurosignals · doi:10.1159/000337115 · Cited by 9,023
Emerging applications of stimuli-responsive polymer materials
Stuart, M. A. C., Huck, W. T. S., Genzer, J., Müller, M., Ober, C. K., Stamm, M., Sukhorukov, G. B., Szleifer, I. G., Tsukruk, V. V., Urban, M. W., et al. (2010) · Nature Materials · doi:10.1038/nmat2614 · Cited by 5,798
MANTOVANI, A., SOZZANI, S., LOCATI, M., ALLAVENA, P., & SICA, A. (2002) · Trends in Immunology · doi:10.1016/s1471-4906(02)02302-5 · Cited by 5,528
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138 · cited 2×
“Similar to the response in the rest of the body [84, 85], a key feature of the brain’s response to chronically implanted devices is persistent inflammation at the biotic-abiotic interface [99, 106].”
BackgroundMicroglia-mediated neurotoxicity: uncovering the molecular mechanisms
Block, M. L., Zecca, L., & Hong, J.-S. (2007) · Nature Reviews Neuroscience · doi:10.1038/nrn2038 · Cited by 4,110
Microglia: Active sensor and versatile effector cells in the normal and pathologic brain
Hanisch, U.-K., & Kettenmann, H. (2007) · Nature Neuroscience · doi:10.1038/nn1997 · Cited by 3,676
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Research works printed but not linked: 32
- Kellis S, 2010, Conf. Proc. IEEE Eng. Med. Biol. Soc., 2010, 3827
- Kruger J, 2010, Front. Neuroeng., 3, 6
- Prasad A, 2012, J. Neural. Eng., 9
- Wark H A C, 2013, J. Neural. Eng., 10
- Hanson S R, 1980, J. Lab. Clin. Med., 95, 289
- Pollock A L, 2007, Early Brain Tissue Reaction Surrounding the Michigan-Style Microelectrode Arrays Indicates that Extensive Remodeling of Glial and Neuronal Populations Occurs During the Foreign Body Response
- Harris J P, 2011, J. Neural. Eng., 8
- Hess A E, 2013, JoVE, 78
- Harris J P, 2011, J. Neural. Eng., 8
- Chao C C, 1995, Crit. Rev. Neurobiol., 9, 189
- Feuerstein G Z, 1994, Cerebrovasc. Brain Metab. Rev., 6, 341
- Skousen M B J L, 2014, Biomaterials
- Stensaas S S, 1976, Acta Neuropathol (Berl), 35, 187
- McConnell G C, 2009, J. Neural Eng., 6
- Harris J P, 2011, Dissertation
- Jensen W, 2003, 2003 Proc. of the 25th Annual Int. Conf. of the IEEE
- Egert D, 2011, 16th Int. Conf. on Actuators and Microsystems 5–9 June (Beijing), 198
- ChunXiang T, 2005, 27th Annual Int. Conf. of the IEEE-EMBS
- Zhu R Y H, 2012, J. Nanotechnology Eng. Med, 2
- Subbaroyan J, 2006, Conf. Proc. IEEE Eng. Med. Biol. Soc.
- Clement R S, 2003, Proc. 25th Annual Int. Conf. of the IEEE EMBS (Cancun, Mexico)
- Lee K, 2004, P. Ann Int. IEEE Embs., 26, 4326
- Kato Y, 2006, Proc. IEEE, 1-15, 5444
- Kim D-H, 2010, Nat. Mater
- Nguyen J K, 2014, J. Neural. Eng., 11
- Dalby M J, 2007, Int. J. Nanomed., 2, 373
- Azemi E, 2008, Acta Biomater.
- Green R A, 2009, 4th Int. IEEE/EMBS Conf. on Neural Engineering
- Indwelling Neural Implants, 2008, Strategies for Contending with the In vivo Environment
- Voge C M, 2011, J. Neural. Eng., 8
- Hanein Y, 2013, Front. Neural Circuits, 6
- Chen Y-C, 2011, J. Neural. Eng., 8
Cited by
Sorted by citations
A review of the volatiles from the healthy human body
de Lacy Costello, B., Amann, A., Al-Kateb, H., Flynn, C., Filipiak, W., Khalid, T., Osborne, D., & Ratcliffe, N. M. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/1/014001 · Cited by 1,042
Ajiboye, A. B., Willett, F. R., Young, D. R., Memberg, W. D., Murphy, B. A., Miller, J. P., Walter, B. L., Sweet, J. A., Hoyen, H. A., Keith, M. W., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30601-3 · Cited by 862
Amann, A., Costello, B. D. L., Miekisch, W., Schubert, J., Buszewski, B., Pleil, J., Ratcliffe, N., & Risby, T. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/3/034001 · Cited by 804
Recent advances in nanocellulose for biomedical applications
Jorfi, M., & Foster, E. J. (2014) · Journal of Applied Polymer Science · doi:10.1002/app.41719 · Cited by 737
Self-citationMaterials and technologies for soft implantable neuroprostheses
Lacour, S. P., Courtine, G., & Guck, J. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.63 · Cited by 738
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 695
Glial responses to implanted electrodes in the brain
Salatino, J. W., Ludwig, K. A., Kozai, T. D. Y., & Purcell, E. K. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0154-1 · Cited by 642
Next-generation probes, particles, and proteins for neural interfacing
Rivnay, J., Wang, H., Fenno, L., Deisseroth, K., & Malliaras, G. G. (2017) · Science Advances · doi:10.1126/sciadv.1601649 · Cited by 514
Bioinspired Polymer Systems with Stimuli-Responsive Mechanical Properties
de Espinosa, L. M., Meesorn, W., Moatsou, D., & Weder, C. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00168 · Cited by 422
Self-citationA Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Conducting Polymers for Neural Prosthetic and Neural Interface Applications
Green, R. A., & Abidian, M. R. (2015) · Advanced Materials · doi:10.1002/adma.201501810 · Cited by 405
Boehler, C., Carli, S., Fadiga, L., Stieglitz, T., & Asplund, M. (2020) · Nature Protocols · doi:10.1038/s41596-020-0389-2 · Cited by 324
Hernandez, J. L., & Woodrow, K. A. (2022) · Advanced Healthcare Materials · doi:10.1002/adhm.202102087 · Cited by 278
A review on mechanical considerations for chronically-implanted neural probes
Lecomte, A., Descamps, E., & Bergaud, C. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8b4f · Cited by 205
Flexible, Penetrating Brain Probes Enabled by Advances in Polymer Microfabrication
Weltman, A., Yoo, J. J., & Meng, E. F. (2016) · Micromachines · doi:10.3390/mi7100180 · Cited by 192
Spencer, K. C., Sy, J. C., Ramadi, K. B., Graybiel, A. M., Langer, R., & Cima, M. J. (2017) · Scientific Reports · doi:10.1038/s41598-017-02107-2 · Cited by 193
Biointegrated and Wirelessly Powered Implantable Brain Devices: A Review
Das, R., Moradi, F., & Heidari, H. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.2966920 · Cited by 174
Szostak, K. M., Grand, L., & Constandinou, T. G. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00665 · Cited by 183
Wen, X., Wang, B., Huang, S., Liu, T. “., Lee, M., Chung, P., Chow, Y. T., Huang, I.-W., Monbouquette, H. G., Maidment, N. T., et al. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.01.060 · Cited by 162
Barrese, J. C., Aceros, J., & Donoghue, J. P. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026003 · Cited by 161
Luan, L., Robinson, J. T., Aazhang, B., Chi, T., Yang, K., Li, X., Rathore, H., Singer, A., Yellapantula, S., Fan, Y., et al. (2020) · Neuron · doi:10.1016/j.neuron.2020.10.011 · Cited by 150
Rapid prototyping of soft bioelectronic implants for use as neuromuscular interfaces
Afanasenkau, D., Kalinina, D., Lyakhovetskii, V., Tondera, C., Gorsky, O., Moosavi, S., Pavlova, N., Merkulyeva, N., Kalueff, A. V., Minev, I. R., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00615-7 · Cited by 148
Mechanical and Biological Interactions of Implants with the Brain and Their Impact on Implant Design
Prodanov, D., & Delbeke, J. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00011 · Cited by 152
Wearable and Implantable Electroceuticals for Therapeutic Electrostimulations
Long, Y., Li, J., Yang, F., Wang, J., & Wang, X. (2021) · Advanced Science · doi:10.1002/advs.202004023 · Cited by 141
Translational opportunities and challenges of invasive electrodes for neural interfaces
Shen, K., Chen, O., Edmunds, J. L., Piech, D. K., & Maharbiz, M. M. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01021-5 · Cited by 150
Recent Progress in Materials Chemistry to Advance Flexible Bioelectronics in Medicine
Balakrishnan, G., Song, J., Mou, C., & Bettinger, C. J. (2021) · Advanced Materials · doi:10.1002/adma.202106787 · Cited by 135
Stability of PEDOT:PSS‐Coated Gold Electrodes in Cell Culture Conditions
Dijk, G., Rutz, A. L., & Malliaras, G. G. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201900662 · Cited by 132
Brain Machine Interfaces for Vision Restoration: The Current State of Cortical Visual Prosthetics
Niketeghad, S., & Pouratian, N. (2018) · Neurotherapeutics · doi:10.1007/s13311-018-0660-1 · Cited by 131
Guidelines to Study and Develop Soft Electrode Systems for Neural Stimulation
Schiavone, G., Kang, X., Fallegger, F., Gandar, J., Courtine, G., & Lacour, S. P. (2020) · Neuron · doi:10.1016/j.neuron.2020.10.010 · Cited by 125
Significant Enhancement of PEDOT Thin Film Adhesion to Inorganic Solid Substrates with EDOT-Acid
Wei, B., Liu, J., Ouyang, L., Kuo, C.-C., & Martin, D. C. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b03350 · Cited by 120
Krauhausen, I., Coen, C., Spolaor, S., Gkoupidenis, P., & van de Burgt, Y. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202307729 · Cited by 126
Lee, H. C., Ejserholm, F., Gaire, J., Currlin, S., Schouenborg, J., Wallman, L., Bengtsson, M., Park, K., & Otto, K. J. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa68f0 · Cited by 115
Romano, G., Almeida, M., Coelho, A. V., Cutignano, A., Gonçalves, L. G., Hansen, E. H., Khnykin, D., Mass, T., Ramšak, A., Rocha, M. S., et al. (2022) · Marine Drugs · doi:10.3390/md20040219 · Cited by 117
Tian, L., Prabhakaran, M. P., Hu, J., Chen, M., Besenbacher, F., & Ramakrishna, S. (2016) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2016.05.032 · Cited by 108
Does Impedance Matter When Recording Spikes With Polytrodes?
Neto, J. P., Baião, P., Lopes, G., Frazão, J., Nogueira, J., Fortunato, E. M. C., Barquinha, P. M. C., & Kampff, A. R. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00715 · Cited by 103
Review: Human Intracortical Recording and Neural Decoding for Brain–Computer Interfaces
Brandman, D. M., Cash, S. S., & Hochberg, L. R. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2677443 · Cited by 104
Interactions of Neurons with Physical Environments
Marcus, M., Baranes, K., Park, M., Choi, I. S., Kang, K., & Shefi, O. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201700267 · Cited by 105
Recent advances in neural electrode–tissue interfaces
Woeppel, K., Yang, Q., & Cui, X. T. (2017) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2017.09.003 · Cited by 99
Nanotechnology and Nanomaterials for Improving Neural Interfaces
Wang, M., Mi, G., Shi, D., Bassous, N. J., Hickey, D. J., & Webster, T. J. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201700905 · Cited by 99
Naz, S., Ali, J. S., & Zia, M. (2019) · Bio-Design and Manufacturing · doi:10.1007/s42242-019-00049-4 · Cited by 99
Jezierski, T. A., Walczak, M., Ligor, T., Rudnicka, J., & Buszewski, B. (2015) · Journal of Breath Research · doi:10.1088/1752-7155/9/2/027001 · Cited by 97
Implantation of Neural Probes in the Brain Elicits Oxidative Stress
Ereifej, E. S., Rial, G. M., Hermann, J. K., Smith, C. S., Meade, S. M., Rayyan, J., Chen, K., He, F., & Capadona, J. R. (2018) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2018.00009 · Cited by 94
Self-citationKleber, C., Brüns, M., Lienkamp, K., Rühe, J., & Asplund, M. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.05.056 · Cited by 92
Martins, N. R. B., Angelica, A., Chakravarthy, K., Svidinenko, Y., Boehm, F. J., Opris, I., Lebedev, M. A., Swan, M., Garan, S. A., Rosenfeld, J. V., et al. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00112 · Cited by 91
In vitro and in vivo biostability assessment of chronically-implanted Parylene C neural sensors
Lecomte, A., Degache, A., Descamps, É., Dahan, L., & Bergaud, C. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.05.057 · Cited by 91
Bianchi, M., Salvo, A. D., Asplund, M., Carli, S., Lauro, M. D., Schulze‐Bonhage, A., Stieglitz, T., Fadiga, L., & Biscarini, F. (2022) · Advanced Science · doi:10.1002/advs.202104701 · Cited by 93
Bioinspired Materials for In Vivo Bioelectronic Neural Interfaces
Woods, G. A., Rommelfanger, N. J., & Hong, G. (2020) · Matter · doi:10.1016/j.matt.2020.08.002 · Cited by 89
Sharafkhani, N., Kouzani, A. Z., Adams, S. D., Long, J. M., Lissorgues, G., Rousseau, L., & Orwa, J. O. (2021) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2021.109388 · Cited by 86
A Parylene Neural Probe Array for Multi-Region Deep Brain Recordings
Wang, X., Weltman, A., Xu, H., Slingsby-Smith, Z., Lecomte, A., Scholten, K., Song, D. B., & Meng, E. F. (2020) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2020.3000235 · Cited by 87
Long Term Recordings with Immobile Silicon Probes in the Mouse Cortex
Okun, M., Lak, A., Carandini, M., & Harris, K. D. (2016) · PLoS ONE · doi:10.1371/journal.pone.0151180 · Cited by 87
Bio‐Inspired 3D Artificial Neuromorphic Circuits
Liu, X., Wang, F., Su, J., Zhou, Y., & Ramakrishna, S. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202113050 · Cited by 82
A Mosquito Inspired Strategy to Implant Microprobes into the Brain
Shoffstall, A. J., Srinivasan, S., Willis, M. T., Stiller, A. M., Ecker, M., Voit, W., Pancrazio, J. J., & Capadona, J. R. (2018) · Scientific Reports · doi:10.1038/s41598-017-18522-4 · Cited by 83
Self-citationFlexible, diamond-based microelectrodes fabricated using the diamond growth side for neural sensing
Fan, B., Rusinek, C. A., Thompson, C. H., Setien, M. B., Guo, Y., Rechenberg, R., Gong, Y. P., Weber, A. J., Becker, M., Purcell, E. K., et al. (2020) · Microsystems & Nanoengineering · doi:10.1038/s41378-020-0155-1 · Cited by 78
Melatonin improves quality and longevity of chronic neural recording
Golabchi, A., Wu, B., Li, X., Carlisle, D. L., Kozai, T. D. Y., Friedlander, R. M., & Cui, X. T. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.07.026 · Cited by 74
Martin, D. C. (2015) · MRS Communications · doi:10.1557/mrc.2015.17 · Cited by 79
Neural interfaces engineered via micro- and nanostructured coatings
Chen, N., Tian, L., Patil, A. C., Peng, S., Yang, I. H., Thakor, N. V., & Ramakrishna, S. (2017) · Nano Today · doi:10.1016/j.nantod.2017.04.007 · Cited by 74
Bofan, M., Mores, N., Baron, M. S., Dabrowska, M. E., Valente, S., Schmid, M., Trové, A., Conforto, S., Zini, G., Cattani, P., et al. (2013) · Journal of Breath Research · doi:10.1088/1752-7155/7/1/017103 · Cited by 72
Neural and electromyography PEDOT electrodes for invasive stimulation and recording
Rossetti, N., Hagler, J., Kateb, P., & Cicoira, F. (2021) · Journal of Materials Chemistry C · doi:10.1039/d1tc00625h · Cited by 72
Neuroadhesive protein coating improves the chronic performance of neuroelectronics in mouse brain
Golabchi, A., Woeppel, K. M., Li, X., Lagenaur, C. F., & Cui, X. T. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112096 · Cited by 73
A bilayered PVA/PLGA-bioresorbable shuttle to improve the implantation of flexible neural probes
Pas, J., Rutz, A. L., Quilichini, P., Slézia, A., Ghestem, A., Kaszás, A., Donahue, M. J., Curto, V. F., O'Connor, R. P., Bernard, C., et al. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aadc1d · Cited by 69
Biological and bionic hands: natural neural coding and artificial perception
Bensmaia, S. J. (2015) · Philosophical Transactions of the Royal Society B Biological Sciences · doi:10.1098/rstb.2014.0209 · Cited by 67
A comparison of insertion methods for surgical placement of penetrating neural interfaces
Thielen, B., & Meng, E. F. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abf6f2 · Cited by 78
Implantable Self‐Powered Systems for Electrical Stimulation Medical Devices
Cui, X. J., Wu, L., Zhang, C., & Li, Z. (2024) · Advanced Science · doi:10.1002/advs.202412044 · Cited by 75
A Meta-Analysis of Intracortical Device Stiffness and Its Correlation with Histological Outcomes
Stiller, A. M., Black, B. J., Kung, C., Ashok, A., Cogan, S. F., Varner, V. D., & Pancrazio, J. J. (2018) · Micromachines · doi:10.3390/mi9090443 · Cited by 64
Considerations for hydrogel applications to neural bioelectronics
Goding, J. A., Vallejo‐Giraldo, C., Syed, O., & Green, R. A. (2018) · Journal of Materials Chemistry B · doi:10.1039/c8tb02763c · Cited by 65
Translational Neuroelectronics
Jastrzebska‐Perfect, P., Chowdhury, S., Spyropoulos, G. D., Zhao, Z., Cea, C., Gelinas, J. N., & Khodagholy, D. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201909165 · Cited by 68
Thinking Small: Progress on Microscale Neurostimulation Technology
Pancrazio, J. J., Deku, F., Ghazavi, A., Stiller, A. M., Rihani, R., Frewin, C. L., Varner, V. D., Gardner, T. J., & Cogan, S. F. (2017) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/ner.12716 · Cited by 60
Hsiao, Y., Liao, Y.-H., Chen, H.-L., Chen, P., & Chen, F. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b00916 · Cited by 64
Influence of resveratrol release on the tissue response to mechanically adaptive cortical implants
Nguyen, J. K., Jorfi, M., Buchanan, K. L., Park, D. J., Foster, E. J., Tyler, D. J., Rowan, S. J., Weder, C., & Capadona, J. R. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.11.001 · Cited by 63
Self-citationLet There Be Light—Optoprobes for Neural Implants
Alt, M. T., Fiedler, E., Rudmann, L., Ordonez, J. S., Ruther, P., & Stieglitz, T. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2016.2577518 · Cited by 63
Shoffstall, A. J., Paiz, J. E., Miller, D. M., Rial, G. M., Willis, M. T., Menendez, D. M., Hostler, S. R., & Capadona, J. R. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa9f32 · Cited by 60
Self-citationBlack, B., Kanneganti, A., Joshi‐Imre, A., Rihani, R. T., Chakraborty, B., Abbott, J., Pancrazio, J. J., & Cogan, S. F. (2018) · Journal of Neurophysiology · doi:10.1152/jn.00181.2018 · Cited by 62
Progress in the Field of Micro-Electrocorticography
Shokoueinejad, M., Park, D., Jung, Y. H., Brodnick, S. K., Novello, J., Dingle, A. M., Swanson, K. I., Baek, D.-H., Suminski, A. J., Lake, W. B., et al. (2019) · Micromachines · doi:10.3390/mi10010062 · Cited by 65
Organic Electrodes and Communications with Excitable Cells
Harris, A. R., & Wallace, G. G. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201700587 · Cited by 60
Cutrone, A., & Micera, S. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201801345 · Cited by 58
Neural Probes for Chronic Applications
Kook, G., Lee, S., Lee, H., Cho, I., & Lee, H. J. (2016) · Micromachines · doi:10.3390/mi7100179 · Cited by 61
Closed-loop interaction with the cerebral cortex: a review of wireless implant technology
Kohler, F., Gkogkidis, C. A., Bentler, C., Wang, X., Gierthmuehlen, M., Fischer, J., Stolle, C., Reindl, L. M., Rickert, J., Stieglitz, T., et al. (2017) · Brain-Computer Interfaces · doi:10.1080/2326263x.2017.1338011 · Cited by 57
Shen, W., Karumbaiah, L., Liu, X., Saxena, T. K., Chen, S., Patkar, R., Bellamkonda, R. V., & Allen, M. G. (2015) · Microsystems & Nanoengineering · doi:10.1038/micronano.2015.10 · Cited by 61
Nanomaterials at the neural interface
Scaini, D., & Ballerini, L. (2017) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2017.12.009 · Cited by 58
Goss-Varley, M., Dona, K. R., McMahon, J. A., Shoffstall, A. J., Ereifej, E. S., Lindner, S. C., & Capadona, J. R. (2017) · Scientific Reports · doi:10.1038/s41598-017-15623-y · Cited by 57
Self-citationToward a New Generation of Bio-Scaffolds for Neural Tissue Engineering: Challenges and Perspectives
Villanueva‐Flores, F., Garcia-Atutxa, I., Santos, A., & Armendáriz‐Borunda, J. (2023) · Pharmaceutics · doi:10.3390/pharmaceutics15061750 · Cited by 57
Liu, C., Li, P., Maria, C. D., Zhao, L., Zhang, H., & Chen, Z. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/8/1665 · Cited by 53
How is flexible electronics advancing neuroscience research?
Chen, Y., Rommelfanger, N. J., Mahdi, A. I., Wu, X., Keene, S. T., Obaid, A., Salleo, A., Wang, H., & Hong, G. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2020.120559 · Cited by 58
Reliable Next-Generation Cortical Interfaces for Chronic Brain–Machine Interfaces and Neuroscience
Maharbiz, M. M., Muller, R., Alon, E., Rabaey, J. M., & Carmena, J. M. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2016.2574938 · Cited by 51
Connecting Biology to Electronics: Molecular Communication via Redox Modality
Liu, Y., Li, J., Tschirhart, T., Terrell, J. L., Kim, E., Tsao, C., Kelly, D. L., Bentley, W. E., & Payne, G. F. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201700789 · Cited by 52
Bruschi, A., Donati, D. M., Choong, P., Lucarelli, E., & Wallace, G. G. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100041 · Cited by 53
Targeting CD14 on blood derived cells improves intracortical microelectrode performance
Bedell, H. W., Hermann, J. K., Ravikumar, M., Lin, S., Rein, A., Li, X., Molinich, E., Smith, P. D., Selkirk, S. M., Miller, R. H., et al. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.02.014 · Cited by 51
Self-citationElectrochemical and biological performance of chronically stimulated conductive hydrogel electrodes
Dalrymple, A. N., Robles, U. A. A., Huynh, M., Nayagam, B. A., Green, R. A., Poole-Warren, L. A., Fallon, J. B., & Shepherd, R. K. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab7cfc · Cited by 51
Christensen, M. B., Wark, H. A. C., & Hutchinson, D. T. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2015.11.012 · Cited by 49
Chen, K., Wellman, S. M., Yaxiaer, Y., Eles, J. R., & Kozai, T. D. Y. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2020.120526 · Cited by 46
Nano-Architectural Approaches for Improved Intracortical Interface Technologies
Kim, Y., Meade, S. M., Chen, K., He, F., Rayyan, J., Hess‐Dunning, A., & Ereifej, E. S. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00456 · Cited by 56
Potter–Baker, K. A., Stewart, W. G., Tomaszewski, W. H., Wong, C., Meador, W. D., Ziats, N. P., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/4/046002 · Cited by 49
Self-citationState of the Art of Non-Invasive Electrode Materials for Brain–Computer Interface
Yuan, H., Li, Y., Yang, J., Li, H., Yang, Q.-Y., Guo, C., Zhu, S., & Shu, X. (2021) · Micromachines · doi:10.3390/mi12121521 · Cited by 51
Engineering strategies towards overcoming bleeding and glial scar formation around neural probes
Otte, E., Vlachos, A., & Asplund, M. (2022) · Cell and Tissue Research · doi:10.1007/s00441-021-03567-9 · Cited by 54
Autotaxin and lysophospholipids in rheumatoid arthritis.
Bourgoin, S. G., & Zhao, C. (2010) · PubMed · Cited by 49
In vivo spatiotemporal dynamics of astrocyte reactivity following neural electrode implantation
Savya, S. P., Li, F., Lam, S., Wellman, S. M., Stieger, K. C., Chen, K., Eles, J. R., & Kozai, T. D. Y. (2022) · Biomaterials · doi:10.1016/j.biomaterials.2022.121784 · Cited by 46
Bedell, H. W., Schaub, N. J., Capadona, J. R., & Ereifej, E. S. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.11.017 · Cited by 45
Self-citationSignal Generation, Acquisition, and Processing in Brain Machine Interfaces: A Unified Review
Salahuddin, U., & Gao, P. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.728178 · Cited by 50
Fischer, S., Trefz, P., Bergmann, A., Steffens, M., Ziller, M., Miekisch, W., Schubert, J. K., Köhler, H., & Reinhold, P. (2015) · Journal of Breath Research · doi:10.1088/1752-7155/9/2/027108 · Cited by 46
Spencer, K. C., Sy, J. C., Falcón‐Banchs, R., & Cima, M. J. (2017) · Lab on a Chip · doi:10.1039/c6lc01411a · Cited by 47
Metadata
- Authors
- Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R.
- Affiliations
- University of Fribourg (CH)
- University of Utah (US)
- Louis Stokes Cleveland VA Medical Center (US)
- Corresponding author
- Capadona, Jeffrey R
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2014-12-02
- Volume
- 12
- Issue
- 1
- Pages
- 011001
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- PMC
- PMC4428498
- OpenAlex
- W2056731994
- Cited by
- 384
- References
- 376
- Citations by year
- 2026: 12 · 2025: 26 · 2024: 20 · 2023: 29 · 2022: 31 · 2021: 36 · 2020: 39 · 2019: 33 · 2018: 43 · 2017: 51 · 2016: 27 · 2015: 20 · 2014: 11
- FWCI
- 4.15
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- U.S. Department of Veterans Affairs (B1495-R, PECASE, B7122R)
- National Institute of Neurological Disorders and Stroke (1R01NS082404-01A1)
- Swiss National Science Foundation (NRP 62: Smart Materials, Nr. 406240_126046)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- intracortical microelectrodes, neural interfaces, neuroinflammation, biocompatibility, long-term neural recording, compliant materials, conducting polymers, nanomaterials, bioactive compounds, electrode materials
- MeSH terms
- Action Potentials, Brain, Electrodes, Implanted, Electroencephalography, Equipment Design, Microelectrodes, Neurons, Equipment Failure Analysis, Coated Materials, Biocompatible, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›