The DOI matches its Crossref record; 372 of the 376 references it cites were found in a registry or an index.
Progress towards biocompatible intracortical microelectrodes for neural interfacing applications
Open accessAbstract
To ensure long-term consistent neural recordings, next-generation intracortical microelectrodes are being developed with an increased emphasis on reducing the neuro-inflammatory response. The increased emphasis stems from the improved understanding of the multifaceted role that inflammation may play in disrupting both biologic and abiologic components of the overall neural interface circuit. To combat neuro-inflammation and improve recording quality, the field is actively progressing from traditional inorganic materials towards approaches that either minimizes the microelectrode footprint or that incorporate compliant materials, bioactive molecules, conducting polymers or nanomaterials. However, the immune-privileged cortical tissue introduces an added complexity compared to other biomedical applications that remains to be fully understood. This review provides a comprehensive reflection on the current understanding of the key failure modes that may impact intracortical microelectrode performance. In addition, a detailed overview of the current status of various materials-based approaches that have gained interest for neural interfacing applications is presented, and key challenges that remain to be overcome are discussed. Finally, we present our vision on the future directions of materials-based treatments to improve intracortical microelectrodes for neural interfacing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Intracortical microelectrodes, used in applications ranging from recent advances in speech-to-text with ALS patients (Willett et al., 2023), allowing primates to play pong (Play Studio, n.d.) to clinical trials for motor deficit treatments (Gilja et al., 2015) face a decline in recording quality over time (Chestek et al., 2011; Jorfi et al., 2014; Kozai et al., 2015).”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Jorfi et al., 2014
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McCord, J. M., & Fridovich, I. (1969) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)63504-5 · Cited by 12,952
Polazzi, E., Mengoni, I., Caprini, M., Peña‐Altamira, E., Kurtys, E., & Monti, B. (2012) · Neurosignals · doi:10.1159/000337115 · Cited by 9,023
Emerging applications of stimuli-responsive polymer materials
Stuart, M. A. C., Huck, W. T. S., Genzer, J., Müller, M., Ober, C. K., Stamm, M., Sukhorukov, G. B., Szleifer, I. G., Tsukruk, V. V., Urban, M. W., et al. (2010) · Nature Materials · doi:10.1038/nmat2614 · Cited by 5,798
MANTOVANI, A., SOZZANI, S., LOCATI, M., ALLAVENA, P., & SICA, A. (2002) · Trends in Immunology · doi:10.1016/s1471-4906(02)02302-5 · Cited by 5,528
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138 · cited 2×
“Similar to the response in the rest of the body [84, 85], a key feature of the brain’s response to chronically implanted devices is persistent inflammation at the biotic-abiotic interface [99, 106].”
BackgroundMicroglia-mediated neurotoxicity: uncovering the molecular mechanisms
Block, M. L., Zecca, L., & Hong, J.-S. (2007) · Nature Reviews Neuroscience · doi:10.1038/nrn2038 · Cited by 4,110
Microglia: Active sensor and versatile effector cells in the normal and pathologic brain
Hanisch, U.-K., & Kettenmann, H. (2007) · Nature Neuroscience · doi:10.1038/nn1997 · Cited by 3,676
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Structural and molecular interrogation of intact biological systems
Chung, K., Wallace, J., Kim, S.-Y., Kalyanasundaram, S., Andalman, A. S., Davidson, T. J., Mirzabekov, J. J., Zalocusky, K. A., Mattis, J., Denisin, A. K., et al. (2013) · Nature · doi:10.1038/nature12107 · Cited by 2,008
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Large-scale recording of neuronal ensembles
Buzsáki, G. (2004) · Nature Neuroscience · doi:10.1038/nn1233 · Cited by 1,875
Brain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875
The glial scar and central nervous system repair
Fawcett, J. W., & Asher, R. A. (1999) · Brain Research Bulletin · doi:10.1016/s0361-9230(99)00072-6 · Cited by 1,808
Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics
Kim, D.-H., Viventi, J., Amsden, J. J., Xiao, J., Vigeland, L., Kim, Y.-S., Blanco, J. A., Panilaitis, B., Frechette, E. S., Contreras, D., et al. (2010) · Nature Materials · doi:10.1038/nmat2745 · Cited by 1,721
David, S., & Aguayo, A. J. (1981) · Science · doi:10.1126/science.6171034 · Cited by 1,698
Stimuli responsive polymers for biomedical applications
Alarcón, C. D. L. H., Pennadam, S. S., & Alexander, C. (2005) · Chemical Society Reviews · doi:10.1039/b406727d · Cited by 1,692
Conducting polymers in biomedical engineering
Guimard, N. K., Gomez, N., & Schmidt, C. E. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.012 · Cited by 1,599
Direct Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,542
Future perspectives and recent advances in stimuli-responsive materials
Roy, D., Cambre, J. N., & Sumerlin, B. S. (2009) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2009.10.008 · Cited by 1,511
Biological Responses to Materials
Anderson, J. M. (2001) · Annual Review of Materials Research · doi:10.1146/annurev.matsci.31.1.81 · Cited by 1,465
HMGB1 and RAGE in Inflammation and Cancer
Sims, G. P., Rowe, D. C., Rietdijk, S. T., Herbst, R., & Coyle, A. J. (2010) · Annual Review of Immunology · doi:10.1146/annurev.immunol.021908.132603 · Cited by 1,436
Astrocyte-endothelial Interactions and Blood-Brain Barrier Permeability*
Abbott, N. J. (2002) · Journal of Anatomy · doi:10.1046/j.1469-7580.2002.00064.x · Cited by 1,168
Microglia: Intrinsic immuneffector cell of the brain
Gehrmann, J., Matsumoto, Y., & Kreutzberg, G. W. (1995) · Brain Research Reviews · doi:10.1016/0165-0173(94)00015-h · Cited by 1,111
Stimulation of neurite outgrowth using an electrically conducting polymer
Schmidt, C. E., Shastri, V. P., Vacanti, J. P., & Langer, R. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.17.8948 · Cited by 1,072
In vivo recordings of brain activity using organic transistors
Khodagholy, D., Doublet, T., Quilichini, P., Gurfinkel, M., Leleux, P., Ghestem, A., Ismailova, E., Hervé, T., Sanaur, S., Bernard, C., et al. (2013) · Nature Communications · doi:10.1038/ncomms2573 · Cited by 1,057
Stimuli-Responsive Polymer Nanocomposites Inspired by the Sea Cucumber Dermis
Capadona, J. R., Shanmuganathan, K., Tyler, D. J., Rowan, S. J., & Weder, C. (2008) · Science · doi:10.1126/science.1153307 · Cited by 965
Self-citationBrown, B. N., Valentin, J. E., Stewart-Akers, A. M., McCabe, G. P., & Badylak, S. F. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.11.040 · Cited by 896
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
Campbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881
Tungsten Microelectrode for Recording from Single Units
Hubel, D. H. (1957) · Science · doi:10.1126/science.125.3247.549 · Cited by 864
Brain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S. T., Spence, A. J., Isaacson, M. S., Craighead, H. G., Turner, J. N., & Shain, W. G. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 811
Minocycline selectively inhibits M1 polarization of microglia
Kobayashi, K., Imagama, S., Ohgomori, T., Hirano, K., Uchimura, K., Sakamoto, K., Hirakawa, A., Takeuchi, H., Suzumura, A., Ishiguro, N., et al. (2013) · Cell Death & Disease · doi:10.1038/cddis.2013.54 · Cited by 742
Carbon nanotube coating improves neuronal recordings
Keefer, E. W., Botterman, B. R., Romero, M. I., Rossi, A. F., & Gross, G. W. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.174 · Cited by 721
Kozai, T. D. Y., Langhals, N. B., Patel, P. R., Deng, X., Zhang, H., Smith, K. L., Lahann, J., Kotov, N. A., & Kipke, D. R. (2012) · Nature Materials · doi:10.1038/nmat3468 · Cited by 721
Conducting polymers for neural interfaces: Challenges in developing an effective long-term implant
Green, R. A., Lovell, N. H., Wallace, G. G., & Poole-Warren, L. A. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.047 · Cited by 691
Gao, H., Jiang, J., Wilson, B. C., Zhang, W., Hong, J., & Liu, B. (2002) · Journal of Neurochemistry · doi:10.1046/j.1471-4159.2002.00928.x · Cited by 690
Stimuli‐Responsive Polymeric Systems for Biomedical Applications
Mano, J. F. (2008) · Advanced Engineering Materials · doi:10.1002/adem.200700355 · Cited by 673
Chemically Functionalized Carbon Nanotubes as Substrates for Neuronal Growth
Hu, H., Ni, Y., Montana, V., Haddon, R. C., & Parpura, V. (2004) · Nano Letters · doi:10.1021/nl035193d · Cited by 672
Carbon Nanotube Substrates Boost Neuronal Electrical Signaling
Lovat, V., Pantarotto, D., Lagostena, L., Cacciari, B., Grandolfo, M., Righi, M., Spalluto, G., Prato, M., & Ballerini, L. (2005) · Nano Letters · doi:10.1021/nl050637m · Cited by 648
Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646
Flexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644
Stimuli-responsive polymers and their applications in drug delivery
Bawa, P., Pillay, V., Choonara, Y. E., & du Toit, L. C. (2009) · Biomedical Materials · doi:10.1088/1748-6041/4/2/022001 · Cited by 643
Ludwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638
Molecular Functionalization of Carbon Nanotubes and Use as Substrates for Neuronal Growth
Mattson, M. P., Haddon, R. C., & Rao, A. M. (2000) · Journal of Molecular Neuroscience · doi:10.1385/jmn:14:3:175 · Cited by 636
Cerebral Astrocyte Response to Micromachined Silicon Implants
Turner, J. N., Shain, W. G., Szarowski, D. H., Andersen, M., Martins, S., Isaacson, M. S., & Craighead, H. G. (1999) · Experimental Neurology · doi:10.1006/exnr.1998.6983 · Cited by 603
Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates
Barrese, J. C., Rao, N., Paroo, K., Triebwasser, C., Vargas-Irwin, C., Franquemont, L., & Donoghue, J. P. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066014 · Cited by 600
Brain–machine interfaces to restore motor function and probe neural circuits
Nicolelis, M. A. L. (2003) · Nature reviews. Neuroscience · doi:10.1038/nrn1105 · Cited by 591
Cui, X. T., & Martin, D. C. (2003) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(02)00448-3 · Cited by 590
Astrocyte Responses to CNS Injury
Norenberg, M. D. (1994) · Journal of Neuropathology & Experimental Neurology · doi:10.1097/00005072-199405000-00001 · Cited by 589
Qin, L., Liu, Y., Wang, T., Wei, S.-J., Block, M. L., Wilson, B., Liu, B., & Hong, J.-S. (2004) · Journal of Biological Chemistry · doi:10.1074/jbc.m307657200 · Cited by 574
Direct control of a computer from the human central nervous system
Kennedy, P. R., Bakay, R. A. E., Moore, M. M., Adams, K. D., & Goldwaithe, J. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847815 · Cited by 573
Pyramidal tract activity associated with a conditioned hand movement in the monkey.
Evarts, E. V. (1966) · Journal of Neurophysiology · doi:10.1152/jn.1966.29.6.1011 · Cited by 571
Schwartz, A., Kettner, R. E., & Georgopoulos, A. P. (1988) · Journal of Neuroscience · doi:10.1523/jneurosci.08-08-02913.1988 · Cited by 565
Toll receptors, CD14, and macrophage activation and deactivation by LPS
Dobrovolskaia, M. A., & Vogel, S. N. (2002) · Microbes and Infection · doi:10.1016/s1286-4579(02)01613-1 · Cited by 562
Fabrication and biocompatibility of polypyrrole implants suitable for neural prosthetics.
George, P. M., Lyckman, A., Laván, D., Hegde, A., Leung, Y., Avasare, R., Testa, C., Alexander, P. M., Langer, R., & Sur, M. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.09.037 · Cited by 560
Jones, L. L., Margolis, R. U., & Tuszynski, M. H. (2003) · Experimental Neurology · doi:10.1016/s0014-4886(03)00087-6 · Cited by 559
An Integrated-Circuit Approach to Extracellular Microelectrodes
Wise, K. D., Angell, J. B., & Starr, A. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502738 · Cited by 544
Naturally derived myocardial matrix as an injectable scaffold for cardiac tissue engineering
Singelyn, J. M., DeQuach, J. A., Seif-Naraghi, S. B., Littlefield, R. B., Schup-Magoffin, P. J., & Christman, K. L. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.06.045 · Cited by 535
Clinical trials of resveratrol
Patel, K. R., Scott, E. N., Brown, V. A., Gescher, A. J., Steward, W. P., & Brown, K. (2011) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2010.05853.x · Cited by 524
Carbon nanotubes might improve neuronal performance by favouring electrical shortcuts
Cellot, G., Cilia, E., Cipollone, S., Rančić, V., Sucapane, A., Giordani, S., Gambazzi, L., Markram, H., Grandolfo, M., Scaini, D., et al. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.374 · Cited by 523
Richardson-Burns, S. M., Hendricks, J. L., Foster, B., Povlich, L. K., Kim, D., & Martin, D. C. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.11.026 · Cited by 505
Nanomaterials for Neural Interfaces
Kotov, N. A., Winter, J. O., Clements, I. P., Jan, E., Timko, B. P., Campidelli, S., Pathak, S., Mazzatenta, A., Lieber, C. M., Prato, M., et al. (2009) · Advanced Materials · doi:10.1002/adma.200801984 · Cited by 504
Wadhwa, R., Lagenaur, C. F., & Cui, X. T. (2005) · Journal of Controlled Release · doi:10.1016/j.jconrel.2005.10.027 · Cited by 498
MCP-1: Chemoattractant with a role beyond immunity: A review
Yadav, A., Saini, V., & Arora, S. (2010) · Clinica Chimica Acta · doi:10.1016/j.cca.2010.07.006 · Cited by 488
Chronic Neural Recording Using Silicon-Substrate Microelectrode Arrays Implanted in Cerebral Cortex
Vetter, R. J., Williams, J. C., Hetke, J. F., Nunamaker, E. A., & Kipke, D. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826680 · Cited by 484
Jones, L. L., Yamaguchi, Y., Stallcup, W. B., & Tuszynski, M. H. (2002) · Journal of Neuroscience · doi:10.1523/jneurosci.22-07-02792.2002 · Cited by 482
Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
Edell, D. J., Toi, V. V., McNeil, V. M., & Clark, L. D. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141202 · Cited by 481
McConnell, G. C., Rees, H. D., Levey, A. I., Gutekunst, C.-A., Gross, R. E., & Bellamkonda, R. V. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/5/056003 · Cited by 480
Restoration of neural output from a paralyzed patient by a direct brain connection
Kennedy, P. R., & Bakay, R. A. E. (1998) · Neuroreport · doi:10.1097/00001756-199806010-00007 · Cited by 475
Neural probe design for reduced tissue encapsulation in CNS
Seymour, J. P., & Kipke, D. R. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.024 · Cited by 462
The electrical properties of metal microelectrodes
Robinson, D. A. (1968) · Proceedings of the IEEE · doi:10.1109/proc.1968.6458 · Cited by 459
Friedlander, D. R., Milev, P., Karthikeyan, L., Margolis, R. K., Margolis, R. U., & Grumet, M. (1994) · The Journal of Cell Biology · doi:10.1083/jcb.125.3.669 · Cited by 454
Kim, D., & Martin, D. C. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.12.021 · Cited by 438
Applications of conducting polymers and their issues in biomedical engineering
Ravichandran, R., Sundarrajan, S., Venugopal, J. R., Mukherjee, S., & Ramakrishna, S. (2010) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0120.focus · Cited by 433
The role of complement in biomaterial-induced inflammation
Nilsson, B., Ekdahl, K. N., Mollnes, T. E., & Lambris, J. D. (2007) · Molecular Immunology · doi:10.1016/j.molimm.2006.06.020 · Cited by 431
Li, N., Zhang, X., Song, Q., Su, R., Zhang, Q., Kong, T., Liu, L., Jin, G. Y., Tang, M., & Cheng, G. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.08.065 · Cited by 431
Multifunctional Nanobiomaterials for Neural Interfaces
Abidian, M. R., & Martin, D. C. (2009) · Advanced Functional Materials · doi:10.1002/adfm.200801473 · Cited by 427
Neural Stimulation with a Carbon Nanotube Microelectrode Array
Wang, K., Fishman, H. A., Dai, H., & Harris, J. S. (2006) · Nano Letters · doi:10.1021/nl061241t · Cited by 420
Cytokines, inflammation, and brain injury: role of tumor necrosis factor-alpha.
FEUERSTEIN, G. Z., Liu, T., & Barone, F. C. (1994) · PubMed · Cited by 419
Suner, S., Fellows, M. R., Vargas-Irwin, C., Nakata, G. K., & Donoghue, J. P. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.857687 · Cited by 415 · cited 1×
“Additionally a number of primate studies have shown the usefulness of the UEA in BMI applications, such as cursor and prostheses control [57, 58].”
BackgroundMonocyte Chemoattractant Protein-1 Regulation of Blood–Brain Barrier Permeability
Stamatovic, S. M., Shakui, P., Keep, R. F., Moore, B. B., Kunkel, S. L., van Rooijen, N., & Andjelkovic, A. V. (2005) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600055 · Cited by 415
Abidian, M. R., Corey, J. M., Kipke, D. R., & Martin, D. C. (2010) · Small · doi:10.1002/smll.200901868 · Cited by 405
How do immune cells overcome the blood-brain barrier in multiple sclerosis?
Larochelle, C., Alvarez, J. I., & Prat, A. (2011) · FEBS Letters · doi:10.1016/j.febslet.2011.04.066 · Cited by 405
Complex impedance spectroscopy for monitoring tissue responses to inserted neural implants
Williams, J. C., Hippensteel, J. A., Dilgen, J., Shain, W. G., & Kipke, D. R. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/4/007 · Cited by 402
XENOGENEIC EXTRACELLULAR MATRIX GRAFTS ELICIT A TH2-RESTRICTED IMMUNE RESPONSE1
Allman, A. J., McPherson, T. B., Badylak, S. F., Merrill, L. C., Kallakury, B., Sheehan, C., Raeder, R. H., & Metzger, D. W. (2001) · Transplantation · doi:10.1097/00007890-200106150-00024 · Cited by 388
Neuroscience nanotechnology: progress, opportunities and challenges
Silva, G. A. (2005) · Nature reviews. Neuroscience · doi:10.1038/nrn1827 · Cited by 383
Stamatovic, S. M., Keep, R. F., Kunkel, S. L., & Andjelkovic, A. V. (2003) · Journal of Cell Science · doi:10.1242/jcs.00755 · Cited by 381
Quagliarello, V., Wispelwey, B., Long, W. J., & Scheld, W. M. (1991) · Journal of Clinical Investigation · doi:10.1172/jci115140 · Cited by 372
Subbaroyan, J., Martin, D. C., & Kipke, D. R. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/006 · Cited by 368
Kipke, D. R., Vetter, R. J., Williams, J. C., & Hetke, J. F. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814443 · Cited by 364
Parylene flexible neural probes integrated with microfluidic channels
Takeuchi, S., Ziegler, D., Yoshida, Y., Mabuchi, K., & Suzuki, T. (2005) · Lab on a Chip · doi:10.1039/b417497f · Cited by 361
Stability of polypyrrole and poly(3,4-ethylenedioxythiophene) for biosensor application
Yamato, H., Ohwa, M., & Wernet, W. (1995) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(95)04156-8 · Cited by 360
Selective Stimulation of Cat Sciatic Nerve Using an Array of Varying-Length Microelectrodes
Branner, A., Stein, R. B., & Normann, R. A. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.85.4.1585 · Cited by 359 · cited 1×
“(48) Recent studies have also shown that the UEA’s structure can be further manipulated to create devices that better conform to complex anatomical geometries using variable depth dicing and wet isotropic etching.”
BackgroundNanotools for Neuroscience and Brain Activity Mapping
Alivisatos, A. P., Andrews, A. M., Boyden, E. S., Chun, M., Church, G. M., Deisseroth, K. A., Donoghue, J. P., Fraser, S. E., Lippincott‐Schwartz, J., Looger, L. L., et al. (2013) · ACS Nano · doi:10.1021/nn4012847 · Cited by 359
Mazzatenta, A., Giugliano, M., Campidelli, S., Gambazzi, L., Businaro, L., Markram, H., Prato, M., & Ballerini, L. (2007) · Journal of Neuroscience · doi:10.1523/jneurosci.1051-07.2007 · Cited by 348
Biran, R., Martin, D. C., & Tresco, P. A. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31138 · Cited by 340
Abidian, M. R., & Martin, D. C. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.11.022 · Cited by 339
Cui, X. T., Hetke, J. F., Wiler, J. A., Anderson, D. J., & Martin, D. C. (2001) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(01)00637-9 · Cited by 331
Bjornsson, C. S., Oh, S., Al‐Kofahi, Y., Lim, Y.-J., Smith, K. L., Turner, J. N., De, S., Roysam, B., Shain, W. G., & Kim, S. J. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/3/002 · Cited by 330
Zhong, Y., & Bellamkonda, R. V. (2007) · Brain Research · doi:10.1016/j.brainres.2007.02.024 · Cited by 326
Glass Insulated Platinum Microelectrode
Wolbarsht, M. L., MacNichol, E. F., & Wagner, H. G. (1960) · Science · doi:10.1126/science.132.3436.1309 · Cited by 306
Interfacing Live Cells with Nanocarbon Substrates
Agarwal, S., Zhou, X., Ye, F., He, Q., Chen, G. C. K., Soo, J., Boey, F. Y. C., Zhang, H., & Chen, P. (2010) · Langmuir · doi:10.1021/la9048743 · Cited by 305
Bridging the Brain to the World: A Perspective on Neural Interface Systems
Donoghue, J. P. (2008) · Neuron · doi:10.1016/j.neuron.2008.10.037 · Cited by 300
Kim, D. ‐., Richardson‐Burns, S. M., Hendricks, J. L., Sequera, C., & Martin, D. C. (2007) · Advanced Functional Materials · doi:10.1002/adfm.200500594 · Cited by 299
Prasad, A., Xue, Q.-S., Sankar, V., Nishida, T., Shaw, G., Streit, W. J., & Sanchez, J. C. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/5/056015 · Cited by 298
Toward a comparison of microelectrodes for acute and chronic recordings
Ward, M. P., Rajdev, P., Ellison, C., & Irazoqui, P. P. (2009) · Brain Research · doi:10.1016/j.brainres.2009.05.052 · Cited by 296
Qin, L., Liu, Y., Cooper, C. L., Liu, B., Wilson, B. C., & Hong, J. (2002) · Journal of Neurochemistry · doi:10.1046/j.1471-4159.2002.01210.x · Cited by 294
Conducting polymers grown in hydrogel scaffolds coated on neural prosthetic devices
Kim, D., Abidian, M. R., & Martin, D. C. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30124 · Cited by 293
Ludwig, K. A., Langhals, N. B., Joseph, M. D., Richardson-Burns, S. M., Hendricks, J. L., & Kipke, D. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/1/014001 · Cited by 283
Biomechanical analysis of silicon microelectrode-induced strain in the brain
Lee, H., Bellamkonda, R. V., Sun, W., & Levenston, M. E. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/003 · Cited by 281
de Vos, P., de Haan, B. J., Wolters, G. H. J., STRUBBE, J. H., & Schilfgaarde, R. V. (1997) · Diabetologia · doi:10.1007/s001250050673 · Cited by 279
Flexible and stretchable micro-electrodes for in vitro and in vivo neural interfaces
Lacour, S. P., Benmerah, S., Tarte, E. J., FitzGerald, J. J., Serra, J., McMahon, S. B., Fawcett, J. W., Graudejus, O., Yu, Z., & Morrison, B. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0644-8 · Cited by 276
Zhang, Y., He, Y., Bharadwaj, S., Hammam, N., Carnagey, K., Myers, R., Atala, A., & Van Dyke, M. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.04.005 · Cited by 276
Mechanically-compliant intracortical implants reduce the neuroinflammatory response
Nguyen, J. K., Park, D. J., Skousen, J. L., Hess-Dunning, A. E., Tyler, D. J., Rowan, S. J., Weder, C., & Capadona, J. R. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/056014 · Cited by 274
Self-citationLiu, X., McCreery, D. B., Carter, R. R., Bullara, L. A., Yuen, T. G. H., & Agnew, W. F. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.788468 · Cited by 272
The impact of chronic blood–brain barrier breach on intracortical electrode function
Saxena, T. K., Karumbaiah, L., Gaupp, E. A., Patkar, R., Patil, K., Betancur, M. I., Stanley, G. B., & Bellamkonda, R. V. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.03.007 · Cited by 270
Conducting polymer-hydrogels for medical electrode applications
Green, R. A., Baek, S., Poole-Warren, L. A., & Martens, P. J. (2010) · Science and Technology of Advanced Materials · doi:10.1088/1468-6996/11/1/014107 · Cited by 268
Abidian, M. R., Ludwig, K. A., Marzullo, T., Martin, D. C., & Kipke, D. R. (2009) · Advanced Materials · doi:10.1002/adma.200900887 · Cited by 263
Culture of neural cells on silicon wafers with nano-scale surface topograph
Fan, Y., Cui, F. Z., Hou, S.-B., Xu, Q., Chen, L. N., & Lee, I.-S. (2002) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(02)00181-4 · Cited by 262
Parylene as a Chronically Stable, Reproducible Microelectrode Insulator
Loeb, G. E., Bak, M. J., Salcman, M., & Schmidt, E. M. (1977) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1977.326115 · Cited by 258
Cell attachment functionality of bioactive conducting polymers for neural interfaces
Green, R. A., Lovell, N. H., & Poole-Warren, L. A. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.03.043 · Cited by 258
Doyle, A., Zhang, G., Fattah, E. A. A., Eissa, N. T., & Li, Y. (2011) · The FASEB Journal · doi:10.1096/fj.10-164152 · Cited by 256
Highly stable carbon nanotube doped poly(3,4-ethylenedioxythiophene) for chronic neural stimulation
Luo, X., Weaver, C. L., Zhou, D. D., Greenberg, R. J., & Cui, X. T. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.04.051 · Cited by 255
Potter, K. A., Buck, A. C., Self, W. K., & Capadona, J. R. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/4/046020 · Cited by 242
Self-citationRelationship between intracortical electrode design and chronic recording function
Karumbaiah, L., Saxena, T., Carlson, D., Patil, K., Patkar, R., Gaupp, E. A., Betancur, M., Stanley, G. B., Carin, L., & Bellamkonda, R. V. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.07.016 · Cited by 241
Encapsulation of an Integrated Neural Interface Device With Parylene C
Jui-Mei, H., Rieth, L. W., Normann, R. A., Tathireddy, P., & Solzbacher, F. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2002155 · Cited by 241
The roles of TNF in brain dysfunction and disease
Clark, I. A., Alleva, L. M., & Vissel, B. (2010) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2010.08.007 · Cited by 239
Blind source identification from the multichannel surface electromyogram
Holobar, A., & Farina, D. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/7/r143 · Cited by 238
Decoding spoken words using local field potentials recorded from the cortical surface
Kellis, S., Miller, K., Thomson, K., Brown, R., House, P., & Greger, B. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/5/056007 · Cited by 235
Yamada, H., Fredette, B. J., Shitara, K., Hagihara, K., Miura, R., Ranscht, B., Stallcup, W. B., & Yamaguchi, Y. (1997) · Journal of Neuroscience · doi:10.1523/jneurosci.17-20-07784.1997 · Cited by 228
Shain, W. G., Spataro, L. E., Dilgen, J., Haverstick, K., Retterer, S. T., Isaacson, M. S., Saltzman, W. M., & Turner, J. N. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814800 · Cited by 227
Lund, S., Christensen, K. V., Hedtjärn, M., Mortensen, A. L., Hagberg, H., Falsig, J., Hasseldam, H., Schrattenholz, A. S., Pörzgen, P., & Leist, M. (2006) · Journal of Neuroimmunology · doi:10.1016/j.jneuroim.2006.07.007 · Cited by 217
Long-term implants of Parylene-C coated microelectrodes
Schmidt, E., Mcintosh, J. S., & Bak, M. (2006) · Medical and Biological Engineering and Computing · doi:10.1007/bf02441836 · Cited by 216
Electro-chemical and biological properties of carbon nanotube based multi-electrode arrays
Gabay, T., Ben-David, M., Kalifa, I., Sorkin, R., Abrams, Z. R., Ben‐Jacob, E., & Hanein, Y. (2007) · Nanotechnology · doi:10.1088/0957-4484/18/3/035201 · Cited by 216
Spataro, L. E., Dilgen, J., Retterer, S. T., Spence, A. J., Isaacson, M. S., Turner, J. N., & Shain, W. G. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2004.08.037 · Cited by 215
Chronic response of adult rat brain tissue to implants anchored to the skull
Kim, Y. T., Hitchcock, R. W., Bridge, M. J., & Tresco, P. A. (2003) · Biomaterials · doi:10.1016/j.biomaterials.2003.09.010 · Cited by 215
Sellaro, T. L., Ravindra, A. K., Stolz, D. B., & Badylak, S. F. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0437 · Cited by 214
Lu, Y., Wang, D., Li, T., Zhao, X., Cao, Y., Yang, H., & Duan, Y. Y. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.04.030 · Cited by 214
Biomimetic mechanically adaptive nanocomposites
Shanmuganathan, K., Capadona, J. R., Rowan, S. J., & Weder, C. (2009) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2009.10.005 · Cited by 211
Self-citationNegi, S., Bhandari, R., Rieth, L. W., & Solzbacher, F. (2010) · Biomedical Materials · doi:10.1088/1748-6041/5/1/015007 · Cited by 209
Wireless Neural Recording With Single Low-Power Integrated Circuit
Harrison, R. R., Kier, R. J., Chestek, C. A., Gilja, V., Nuyujukian, P., Ryu, S. I., Greger, B. E., Solzbacher, F., & Shenoy, K. V. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2023298 · Cited by 208
Tanihara, M., Suzuki, Y., Yamamoto, E., Noguchi, A., & Mizushima, Y. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200108)56:2 · Cited by 205
ACTIVITY OF ISOCORTEX AND HIPPOCAMPUS: ELECTRICAL STUDIES WITH MICRO-ELECTRODES
Renshaw, B., Forbes, A., & Morison, B. R. (1940) · Journal of Neurophysiology · doi:10.1152/jn.1940.3.1.74 · Cited by 199
Raynor, J. E., Capadona, J. R., Collard, D. M., Petrie, T. A., & Garcı́a, A. J. (2009) · Biointerphases · doi:10.1116/1.3089252 · Cited by 198
Self-citationElectrochemical polymerization of conducting polymers in living neural tissue
Richardson-Burns, S. M., Hendricks, J. L., & Martin, D. C. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/l02 · Cited by 196
Massia, S. P., Rao, S. S., & Hubbell, J. A. (1993) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)53062-3 · Cited by 195
Implant Size and Fixation Mode Strongly Influence Tissue Reactions in the CNS
Thelin, J., Jörntell, H., Psouni, E., Garwicz, M., Schouenborg, J., Danielsen, N., & Linsmeier, C. E. (2011) · PLoS ONE · doi:10.1371/journal.pone.0016267 · Cited by 195
Silicon microsystems for neuroscience and neural prostheses
Wise, K. D. (2005) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2005.1511497 · Cited by 194
Mechanically adaptive intracortical implants improve the proximity of neuronal cell bodies
Harris, J. P., Capadona, J. R., Miller, R. H., Healy, B. C., Shanmuganathan, K., Rowan, S. J., Weder, C., & Tyler, D. J. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/6/066011 · Cited by 192
Self-citationIn vivo evaluation of artificial surfaces with a nonhuman primate model of arterial thrombosis.
Hanson, S. R., Harker, L. A., Ratner, B. D., & Hoffman, A. S. (1980) · PubMed · Cited by 192
Electrodeposited polypyrrole/carbon nanotubes composite films electrodes for neural interfaces
Lu, Y., Li, T., Zhao, X., Li, M., Cao, Y., Yang, H., & Duan, Y. Y. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.03.022 · Cited by 191
Polypyrrole doped with 2 peptide sequences from laminin
Stauffer, W. R., & Cui, X. T. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.10.024 · Cited by 188
Conductive Single-Walled Carbon Nanotube Substrates Modulate Neuronal Growth
Malarkey, E. B., Fisher, K. A., Bekyarova, E. B., Liu, W., Haddon, R. C., & Parpura, V. (2008) · Nano Letters · doi:10.1021/nl802855c · Cited by 186
Vertically Aligned Carbon Nanofiber Arrays: An Advance toward Electrical–Neural Interfaces
Nguyen-Vu, T. B., Chen, H., Cassell, A. M., Andrews, R. J., Meyyappan, M., & Li, J. (2005) · Small · doi:10.1002/smll.200500175 · Cited by 186
Stern, M. M., Myers, R. L., Hammam, N., Stern, K. A., Eberli, D., Kritchevsky, S. B., Söker, S., & Dyke, M. E. V. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.12.069 · Cited by 185
Allaire, É., Guettier, C., Bruneval, P., Plissonnier, D., & Michel, J. (1994) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(94)70071-0 · Cited by 183
Anti-Inflammatory Polymeric Coatings for Implantable Biomaterials and Devices
Bridges, A. W., & Garcı́a, A. J. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200628 · Cited by 183
Biocompatibility of silicon‐based electrode arrays implanted in feline cortical tissue
Schmidt, S., Horch, K., & Normann, R. A. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820271106 · Cited by 182
Cutler, S. M., & a, A. J. G. X. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00570-7 · Cited by 181
Handbook of Stimuli‐Responsive Materials
(2011) · Wiley eBooks · doi:10.1002/9783527633739 · Cited by 178
Winslow, B. D., & Tresco, P. A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.11.049 · Cited by 178
Abiotic-biotic characterization of Pt/Ir microelectrode arrays in chronic implants
Prasad, A., Xue, Q.-S., Dieme, R., Sankar, V., Mayrand, R. C., Nishida, T., Streit, W. J., & Sanchez, J. C. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00002 · Cited by 178
Histopathological evaluation of materials implanted in the cerebral cortex
Stensaas, S. S., & Stensaas, L. J. (1978) · Acta Neuropathologica · doi:10.1007/bf00689766 · Cited by 177
He, W., McConnell, G. C., & Bellamkonda, R. V. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/009 · Cited by 177
Carbon nanotube-based multi electrode arrays for neuronal interfacing: progress and prospects
Bareket, L., & Hanein, Y. (2013) · Frontiers in Neural Circuits · doi:10.3389/fncir.2012.00122 · Cited by 175
Glia, cytokines, and neurotoxicity.
Chao, C. C., Hu, S., & Peterson, P. K. (1995) · PubMed · Cited by 174
Silicon ribbon cables for chronically implantable microelectrode arrays
Hetke, J. F., Lund, J. L., Najafi, K., Wise, K. D., & Anderson, D. J. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284959 · Cited by 174
Winslow, B. D., Christensen, M. B., Yang, W.-K., Solzbacher, F., & Tresco, P. A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.05.050 · Cited by 171
Plasma‐enhanced chemical vapor deposited silicon carbide as an implantable dielectric coating
Cogan, S. F., Edell, D. J., Guzelian, A. A., Liu, Y. P., & Edell, R. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10152 · Cited by 170
Green, R. A., Lovell, N. H., & Poole-Warren, L. A. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.06.030 · Cited by 170
Biocompatibility of nanoporous alumina membranes for immunoisolation
Flamme, K. E. L., Popat, K. C., Leoni, L., Markiewicz, E. J., LaTempa, T. J., Roman, B. B., Grimes, C. A., & Desai, T. A. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.02.010 · Cited by 170
Effect of graphene oxide on undifferentiated and retinoic acid-differentiated SH-SY5Y cells line
Lv, M., Zhang, Y., Liang, L., Wei, M., Hu, W., Li, X., & Huang, Q. (2012) · Nanoscale · doi:10.1039/c2nr30407d · Cited by 169
Corrosion of tungsten microelectrodes used in neural recording applications
Patrick, E. E., Orazem, M. E., Sanchez, J. C., & Nishida, T. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2011.03.012 · Cited by 168
Huang, Y. H., Sinha, S. R., Tanaka, K., Rothstein, J. D., & Bergles, D. E. (2004) · Journal of Neuroscience · doi:10.1523/jneurosci.5217-03.2004 · Cited by 167
Review of signal distortion through metal microelectrode recording circuits and filters
Nelson, M. J., Pouget, P., Nilsen, E. A., Patten, C. D., & Schall, J. D. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.12.010 · Cited by 167
Fabrication of Responsive, Softening Neural Interfaces
Ware, T. H., Simon, D., Arreaga‐Salas, D., Reeder, J. T., Rennaker, R. L., Keefer, E. W., & Voit, W. (2012) · Advanced Functional Materials · doi:10.1002/adfm.201200200 · Cited by 166
Gheith, M. K., Sinani, V. A., Wicksted, J. P., Matts, R. L., & Kotov, N. A. (2005) · Advanced Materials · doi:10.1002/adma.200500366 · Cited by 165
Integrated wireless neural interface based on the Utah electrode array
Kim, S., Bhandari, R., Klein, M., Negi, S., Rieth, L., Tathireddy, P., Toepper, M., Oppermann, H., & Solzbacher, F. (2009) · Biomedical Microdevices · doi:10.1007/s10544-008-9251-y · Cited by 165
Bio-inspired mechanically-adaptive nanocomposites derived from cotton cellulose whiskers
Shanmuganathan, K., Capadona, J. R., Rowan, S. J., & Weder, C. (2009) · Journal of Materials Chemistry · doi:10.1039/b916130a · Cited by 164
Self-citationAzemi, E., Lagenaur, C. F., & Cui, X. T. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.09.033 · Cited by 164
Stimuli-Responsive Mechanically Adaptive Polymer Nanocomposites
Shanmuganathan, K., Capadona, J. R., Rowan, S. J., & Weder, C. (2009) · ACS Applied Materials & Interfaces · doi:10.1021/am9006337 · Cited by 161
Self-citationPolyimide-based intracortical neural implant with improved structural stiffness
Lee, K.-K., He, J., Singh, A., Massia, S. P., Ehteshami, G., Kim, B., & Raupp, G. B. (2003) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/1/305 · Cited by 161
Behavioral recovery following intrastriatal implantation of microencapsulated PC12 cells
Winn, S. R., Tresco, P. A., Zielinski, B. A., Greene, L. A., Jaeger, C. B., & Aebischer, P. (1991) · Experimental Neurology · doi:10.1016/0014-4886(91)90022-5 · Cited by 161
Challenges and Opportunities for Next-Generation Intracortically Based Neural Prostheses
Gilja, V., Chestek, C. A., Diester, I., Henderson, J. M., Deisseroth, K. A., & Shenoy, K. V. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2107553 · Cited by 160
In vivodeployment of mechanically adaptive nanocomposites for intracortical microelectrodes
Harris, J. P., Hess‐Dunning, A., Rowan, S. J., Weder, C., Zorman, C. A., Tyler, D. J., & Capadona, J. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046010 · Cited by 159
Self-citationRao, L., Zhou, H., Li, T., Li, C., & Duan, Y. Y. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.03.001 · Cited by 159
A Low-Capacitance Multielectrode Probe for Use in Extracellular Neurophysiology
Wise, K. D., & Angell, J. B. (1975) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1975.324562 · Cited by 157
In Vivo Penetration Mechanics and Mechanical Properties of Mouse Brain Tissue at Micrometer Scales
Sharp, A. A., Ortega, A. M., Restrepo, D., Curran-Everett, D., & Gall, K. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2003261 · Cited by 157
Nanoscale neuro-integrative coatings for neural implants
He, W., & Bellamkonda, R. V. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.08.021 · Cited by 156
Extracellular Matrix for Myocardial Repair
Badylak, S. F., Geddes, L., Geddes, L. A., & Obermiller, J. (2005) · The Heart Surgery Forum · doi:10.1532/hsf.917 · Cited by 155
Gheith, M. K., Pappas, T. C., Liopo, A. V., Sinani, V. A., Shim, B. S., Motamedi, M., Wicksted, J. P., & Kotov, N. A. (2006) · Advanced Materials · doi:10.1002/adma.200600878 · Cited by 154
Shaked, I., Porat, Z., Gersner, R., Kipnis, J., & Schwartz, M. (2003) · Journal of Neuroimmunology · doi:10.1016/j.jneuroim.2003.10.049 · Cited by 151
Kennedy, P. R. (1989) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(89)90142-8 · Cited by 151
Wark, H. A. C., Sharma, R., Mathews, K. S., Fernandez, E., Yoo, J., Christensen, B., Tresco, P., Rieth, L., Solzbacher, F., Normann, R. A., et al. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/045003 · Cited by 148
Biostability of micro‐photodiode arrays for subretinal implantation
Hämmerle, H., Kobuch, K., Kohler, K., Nisch, W., Sachs, H., & Stelzle, M. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00185-5 · Cited by 146
Solid-State Electrodes for Multichannel Multiplexed Intracortical Neuronal Recording
BeMent, S. L., Wise, K. D., Anderson, D. J., Najafi, K., & Drake, K. L. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325895 · Cited by 142
Nguyen-Vu, T. B., Chen, H., Cassell, A. M., Andrews, R. J., Meyyappan, M., & Li, J. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.891169 · Cited by 140
Brain tissue reaction to some chronically implanted metals
Dymond, A. M., Le, K., Jurist, J. M., & Crandall, P. H. (1970) · Journal of neurosurgery · doi:10.3171/jns.1970.33.5.0574 · Cited by 140
Research works printed but not linked: 32
- Kellis S, 2010, Conf. Proc. IEEE Eng. Med. Biol. Soc., 2010, 3827
- Kruger J, 2010, Front. Neuroeng., 3, 6
- Prasad A, 2012, J. Neural. Eng., 9
- Wark H A C, 2013, J. Neural. Eng., 10
- Hanson S R, 1980, J. Lab. Clin. Med., 95, 289
- Pollock A L, 2007, Early Brain Tissue Reaction Surrounding the Michigan-Style Microelectrode Arrays Indicates that Extensive Remodeling of Glial and Neuronal Populations Occurs During the Foreign Body Response
- Harris J P, 2011, J. Neural. Eng., 8
- Hess A E, 2013, JoVE, 78
- Harris J P, 2011, J. Neural. Eng., 8
- Chao C C, 1995, Crit. Rev. Neurobiol., 9, 189
- Feuerstein G Z, 1994, Cerebrovasc. Brain Metab. Rev., 6, 341
- Skousen M B J L, 2014, Biomaterials
- Stensaas S S, 1976, Acta Neuropathol (Berl), 35, 187
- McConnell G C, 2009, J. Neural Eng., 6
- Harris J P, 2011, Dissertation
- Jensen W, 2003, 2003 Proc. of the 25th Annual Int. Conf. of the IEEE
- Egert D, 2011, 16th Int. Conf. on Actuators and Microsystems 5–9 June (Beijing), 198
- ChunXiang T, 2005, 27th Annual Int. Conf. of the IEEE-EMBS
- Zhu R Y H, 2012, J. Nanotechnology Eng. Med, 2
- Subbaroyan J, 2006, Conf. Proc. IEEE Eng. Med. Biol. Soc.
- Clement R S, 2003, Proc. 25th Annual Int. Conf. of the IEEE EMBS (Cancun, Mexico)
- Lee K, 2004, P. Ann Int. IEEE Embs., 26, 4326
- Kato Y, 2006, Proc. IEEE, 1-15, 5444
- Kim D-H, 2010, Nat. Mater
- Nguyen J K, 2014, J. Neural. Eng., 11
- Dalby M J, 2007, Int. J. Nanomed., 2, 373
- Azemi E, 2008, Acta Biomater.
- Green R A, 2009, 4th Int. IEEE/EMBS Conf. on Neural Engineering
- Indwelling Neural Implants, 2008, Strategies for Contending with the In vivo Environment
- Voge C M, 2011, J. Neural. Eng., 8
- Hanein Y, 2013, Front. Neural Circuits, 6
- Chen Y-C, 2011, J. Neural. Eng., 8
Cited by
Sorted by citations
A review of the volatiles from the healthy human body
de Lacy Costello, B., Amann, A., Al-Kateb, H., Flynn, C., Filipiak, W., Khalid, T., Osborne, D., & Ratcliffe, N. M. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/1/014001 · Cited by 1,042
Ajiboye, A. B., Willett, F. R., Young, D. R., Memberg, W. D., Murphy, B. A., Miller, J. P., Walter, B. L., Sweet, J. A., Hoyen, H. A., Keith, M. W., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30601-3 · Cited by 862
Amann, A., Costello, B. D. L., Miekisch, W., Schubert, J., Buszewski, B., Pleil, J., Ratcliffe, N., & Risby, T. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/3/034001 · Cited by 804
Recent advances in nanocellulose for biomedical applications
Jorfi, M., & Foster, E. J. (2014) · Journal of Applied Polymer Science · doi:10.1002/app.41719 · Cited by 737
Self-citationMaterials and technologies for soft implantable neuroprostheses
Lacour, S. P., Courtine, G., & Guck, J. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.63 · Cited by 738
Metadata
- Authors
- Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R.
- Affiliations
- University of Fribourg (CH)
- University of Utah (US)
- Louis Stokes Cleveland VA Medical Center (US)
- Corresponding author
- Capadona, Jeffrey R
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2014-12-02
- Volume
- 12
- Issue
- 1
- Pages
- 011001
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- PMC
- PMC4428498
- OpenAlex
- W2056731994
- Cited by
- 384
- References
- 376
- Citations by year
- 2026: 12 · 2025: 26 · 2024: 20 · 2023: 29 · 2022: 31 · 2021: 36 · 2020: 39 · 2019: 33 · 2018: 43 · 2017: 51 · 2016: 27 · 2015: 20 · 2014: 11
- FWCI
- 4.15
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- U.S. Department of Veterans Affairs (B1495-R, PECASE, B7122R)
- National Institute of Neurological Disorders and Stroke (1R01NS082404-01A1)
- Swiss National Science Foundation (NRP 62: Smart Materials, Nr. 406240_126046)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- intracortical microelectrodes, neural interfaces, neuroinflammation, biocompatibility, long-term neural recording, compliant materials, conducting polymers, nanomaterials, bioactive compounds, electrode materials
- MeSH terms
- Action Potentials, Brain, Electrodes, Implanted, Electroencephalography, Equipment Design, Microelectrodes, Neurons, Equipment Failure Analysis, Coated Materials, Biocompatible, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review