The DOI matches its Crossref record; 372 of the 376 references it cites were found in a registry or an index.
Progress towards biocompatible intracortical microelectrodes for neural interfacing applications
Open accessAbstract
To ensure long-term consistent neural recordings, next-generation intracortical microelectrodes are being developed with an increased emphasis on reducing the neuro-inflammatory response. The increased emphasis stems from the improved understanding of the multifaceted role that inflammation may play in disrupting both biologic and abiologic components of the overall neural interface circuit. To combat neuro-inflammation and improve recording quality, the field is actively progressing from traditional inorganic materials towards approaches that either minimizes the microelectrode footprint or that incorporate compliant materials, bioactive molecules, conducting polymers or nanomaterials. However, the immune-privileged cortical tissue introduces an added complexity compared to other biomedical applications that remains to be fully understood. This review provides a comprehensive reflection on the current understanding of the key failure modes that may impact intracortical microelectrode performance. In addition, a detailed overview of the current status of various materials-based approaches that have gained interest for neural interfacing applications is presented, and key challenges that remain to be overcome are discussed. Finally, we present our vision on the future directions of materials-based treatments to improve intracortical microelectrodes for neural interfacing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Intracortical microelectrodes, used in applications ranging from recent advances in speech-to-text with ALS patients (Willett et al., 2023), allowing primates to play pong (Play Studio, n.d.) to clinical trials for motor deficit treatments (Gilja et al., 2015) face a decline in recording quality over time (Chestek et al., 2011; Jorfi et al., 2014; Kozai et al., 2015).”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Jorfi et al., 2014
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Items 201–372 of 372
Endothelial Cell‐Astrocyte Interactions
Goldstein, G. W. (1988) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1988.tb51417.x · Cited by 139
Ware, T., Simon, D., Hearon, K., Liu, C., Shah, S., Reeder, J., Khodaparast, N., Kilgard, M. P., Maitland, D. J., Rennaker, R. L., et al. (2012) · Macromolecular Materials and Engineering · doi:10.1002/mame.201200241 · Cited by 138
Lee, S. M., Yune, T. Y., Kim, S. J., Kim, Y. C., Oh, Y. J., Markelonis, G. J., & Oh, T. H. (2004) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.2004.02780.x · Cited by 137
Tien, L. W., Wu, F., Tang‐Schomer, M. D., Yoon, E., Omenetto, F. G., & Kaplan, D. L. (2013) · Advanced Functional Materials · doi:10.1002/adfm.201203716 · Cited by 136
Yang, J., Kim, D., Hendricks, J. L., Leach, M. K., Northey, R., & Martin, D. C. (2004) · Acta Biomaterialia · doi:10.1016/j.actbio.2004.09.006 · Cited by 135
Moxon, K. A., Kalkhoran, N. M., Markert, M., Sambito, M. A., McKenzie, J. L., & Webster, J. T. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827465 · Cited by 135
Computer control using human intracortical local field potentials
Kennedy, P. R., Kirby, M. T., Moore, M. M., King, B., & Mallory, A. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.834629 · Cited by 134
Long-term changes in the material properties of brain tissue at the implant–tissue interface
Sridharan, A., Rajan, S. D., & Muthuswamy, J. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066001 · Cited by 133
Xiao, Y., Cui, X. T., Hancock, J. M., Bouguettaya, M., Reynolds, J. R., & Martin, D. C. (2004) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2003.12.067 · Cited by 133
Physiologically Responsive, Mechanically Adaptive Bio-Nanocomposites for Biomedical Applications
Jorfi, M., Roberts, M. N., Foster, E. J., & Weder, C. (2013) · ACS Applied Materials & Interfaces · doi:10.1021/am303160j · Cited by 133
Self-citationGosselin, D., & Rivest, S. (2007) · Brain Behavior and Immunity · doi:10.1016/j.bbi.2006.12.004 · Cited by 130
In Vivo Electrical Impedance Spectroscopy of Tissue Reaction to Microelectrode Arrays
Mercanzini, A., Colin, P., Bensadoun, J., Bertsch, A., & Renaud, P. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2018457 · Cited by 130
SU-8 based microprobes for simultaneous neural depth recording and drug delivery in the brain
Altuna, A., Bellistri, E., Cid, E., Aivar, P., Gal, B., Berganzo, J., Gabriel, G., Guimerà‐Brunet, A., Villa, R., Fernández, L. J., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc41364k · Cited by 129
Potter, K. A., Buck, A. C., Self, W. K., Callanan, M. E., Sunil, S., & Capadona, J. R. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.05.035 · Cited by 129
Ceramic-Based Multisite Electrode Arrays for Chronic Single-Neuron Recording
Moxon, K. A., Leiser, S., Gerhardt, G. A., Barbee, K. A., & Chapin, J. K. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.821037 · Cited by 129
Mack, C. L., Vanderlugt, C. L., Neville, K. L., & Miller, S. D. (2003) · Journal of Neuroimmunology · doi:10.1016/j.jneuroim.2003.08.032 · Cited by 128
Potter, K. A., Jorfi, M., Householder, K. T., Foster, E. J., Weder, C., & Capadona, J. R. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.01.018 · Cited by 127
Self-citationPerformance of conducting polymer electrodes for stimulating neuroprosthetics
Green, R. A., Matteucci, P. B., Hassarati, R. T., Giraud, B., Dodds, C. W. D., Chen, S., Byrnes-Preston, P., Suaning, G. J., Poole-Warren, L. A., & Lovell, N. H. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/1/016009 · Cited by 127
Long-term chronic recording from cortical neurons
Schmidt, E. M., Bak, M. J., & McIntosh, J. S. (1976) · Experimental Neurology · doi:10.1016/0014-4886(76)90220-x · Cited by 127
Thiol‐ene/acrylate substrates for softening intracortical electrodes
Ware, T. H., Simon, D., Liu, H. C., Musa, T., Vasudevan, S., Sloan, A. M., Keefer, E. W., Rennaker, R. L., & Voit, W. (2013) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbmb.32946 · Cited by 126
Microglial Ramification Requires Nondiffusible Factors Derived from Astrocytes
Tanaka, J., & Maeda, N. (1996) · Experimental Neurology · doi:10.1006/exnr.1996.0038 · Cited by 126
Nanomaterials and nanosystems for biomedical applications
Mozafari, M. (2007) · Springer eBooks · doi:10.1007/978-1-4020-6289-6 · Cited by 125
Evolution of Physical and Electrochemical Properties of Polypyrrole during Extended Oxidation
Schlenoff, J. B., & Xu, H. L. (1992) · Journal of The Electrochemical Society · doi:10.1149/1.2221238 · Cited by 123
Controlled release of anti-inflammatory agent α-MSH from neural implants
Zhong, Y., & Bellamkonda, R. V. (2005) · Journal of Controlled Release · doi:10.1016/j.jconrel.2005.05.012 · Cited by 121
Carbon nanotubes in neural interfacing applications
Voge, C. M., & Stegemann, J. P. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/1/011001 · Cited by 120
Nanomaterials for Medical Applications
Aguilar, Z. P. (2013) · Elsevier eBooks · doi:10.1016/c2010-0-65569-6 · Cited by 118
Pure graphene oxide doped conducting polymer nanocomposite for bio-interfacing
Luo, X., Weaver, C. L., Tan, S., & Cui, X. T. (2013) · Journal of Materials Chemistry B · doi:10.1039/c3tb00006k · Cited by 117
Surface characterization of porous, biocompatible protein polymer thin films
Buchko, C. J. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00281-7 · Cited by 116
Jensen, W., Yoshida, K., & Hofmann, U. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.872824 · Cited by 115
A Novel Anti‐inflammatory Surface for Neural Electrodes
He, W. J., McConnell, G. C., Schneider, T. M., & Bellamkonda, R. V. (2007) · Advanced Materials · doi:10.1002/adma.200700943 · Cited by 114
Huet, C., Pisselet, C., Mandon‐Pepin, B., Monget, P., & Monniaux, D. (2001) · Journal of Endocrinology · doi:10.1677/joe.0.1690347 · Cited by 114
Well-Ordered Porous Conductive Polypyrrole as a New Platform for Neural Interfaces
Kang, G. E., Borgens, R. B., & Cho, Y. (2011) · Langmuir · doi:10.1021/la104194m · Cited by 113
Toward a self-deploying shape memory polymer neuronal electrode
Sharp, A. A., Panchawagh, H. V., Ortega, A., Artale, R., Richardson-Burns, S., Finch, D. S., Gall, K., Mahajan, R. L., & Restrepo, D. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/l02 · Cited by 113
Conducting polymer coated neural recording electrodes
Harris, A. R., Morgan, S. J., Chen, J., Kapsa, R. M. I., Wallace, G. G., & Paolini, A. G. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/1/016004 · Cited by 112
Iijima, N., Oohira, A., Mori, T., Kitabatake, K., & Kohsaka, S. (1991) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1991.tb08207.x · Cited by 112
Bridging the divide between neuroprosthetic design, tissue engineering and neurobiology
Leach, J. B. (2010) · Frontiers in Neuroengineering · doi:10.3389/neuro.16.018.2009 · Cited by 111
Skousen, J. L., Merriam, S. M. E., Srivannavit, O., Perlin, G., Wise, K. D., & Tresco, P. A. (2011) · Progress in Brain Research · doi:10.1016/b978-0-444-53815-4.00009-1 · Cited by 111
Self-citationMinocycline increases quality and longevity of chronic neural recordings
Rennaker, R. L., Miller, J., Tang, H., & Wilson, D. A. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/l01 · Cited by 109
In vitro assessment of bioactive coatings for neural implant applications
Massia, S. P., Holecko, M. M., & Ehteshami, G. R. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.20009 · Cited by 108
ORIGIN, CONDUCTION AND TERMINATION OF IMPULSES IN THE DORSAL SPINO-CEREBELLAR TRACT OF CATS
Grundfest, H., & Campbell, B. (1942) · Journal of Neurophysiology · doi:10.1152/jn.1942.5.4.275 · Cited by 108
Wafer-scale fabrication of penetrating neural microelectrode arrays
Bhandari, R., Negi, S., & Solzbacher, F. (2010) · Biomedical Microdevices · doi:10.1007/s10544-010-9434-1 · Cited by 107
Karumbaiah, L., Norman, S. E., Rajan, N. B., Anand, S., Saxena, T. K., Betancur, M. I., Patkar, R., & Bellamkonda, R. V. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.05.021 · Cited by 107
The immunogenicity of the extracellular matrix in arterial xenografts
Allaire, É., Bruneval, P., Mandet, C., Becquemin, J., & Michel, J. (1997) · Surgery · doi:10.1016/s0039-6060(97)90267-1 · Cited by 101
Mechanically adaptive nanocomposites for neural interfacing
Capadona, J. R., Tyler, D. J., Zorman, C. A., Rowan, S. J., & Weder, C. (2012) · MRS Bulletin · doi:10.1557/mrs.2012.97 · Cited by 101
Self-citationThin microelectrodes reduce GFAP expression in the implant site in rodent somatosensory cortex
Stice, P., Gilletti, A., Panitch, A., & Muthuswamy, J. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/005 · Cited by 101
Astrocyte Modulation of Neurotoxic Injury
Aschner, M., Sonnewald, U., & Tan, K. H. (2002) · Brain Pathology · doi:10.1111/j.1750-3639.2002.tb00465.x · Cited by 100
Freire, M. A. M., Morya, E., Faber, J., dos Santos, J. R., Guimarães, J. S., Lemos, N. A. M., Sameshima, K., Pereira, A., Ribeiro, S. T. G., & Nicolelis, M. A. L. (2011) · PLoS ONE · doi:10.1371/journal.pone.0027554 · Cited by 100
Polyimide based neural implants with stiffness improvement
Lee, K., Singh, A., He, J., Massia, S. P., Kim, B., & Raupp, G. B. (2004) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2003.10.018 · Cited by 98
Azemi, E., Stauffer, W. R., Gostock, M. S., Lagenaur, C. F., & Cui, X. T. (2008) · Acta Biomaterialia · doi:10.1016/j.actbio.2008.02.028 · Cited by 97
Hess‐Dunning, A., Capadona, J. R., Shanmuganathan, K., Hsu, L., Rowan, S. J., Weder, C., Tyler, D. J., & Zorman, C. A. (2011) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/21/5/054009 · Cited by 96
Self-citationPassivation and corrosion of microelectrode arrays
Schmitt, G., Schultze, J. W., Faßbender, F. J., Buß, G., Luth, H., & Schöning, M. J. (1999) · Electrochimica Acta · doi:10.1016/s0013-4686(99)00094-8 · Cited by 95
Sugama, S., Takenouchi, T., Cho, B., Joh, T. H., Hashimoto, M., & Kitani, H. (2009) · Inflammation & Allergy - Drug Targets · doi:10.2174/187152809789352249 · Cited by 95
Baranauskas, G., Maggiolini, E., Castagnola, E., Ansaldo, A., Mazzoni, A., Angotzi, G. N., Vato, A., Ricci, D., Panzeri, S., & Fadiga, L. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/6/066013 · Cited by 95
Wester, B. A., Lee, R. H., & LaPlaca, M. C. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/2/024002 · Cited by 91
Leung, B. K., Biran, R., Underwood, C. J., & Tresco, P. A. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.03.045 · Cited by 91
House, P. A., MacDonald, J. D., Tresco, P. A., & Normann, R. A. (2006) · Neurosurgical FOCUS · doi:10.3171/foc.2006.20.5.5 · Cited by 91
Półtorak, M., & Freed, W. J. (1989) · Experimental Neurology · doi:10.1016/0014-4886(89)90046-0 · Cited by 89
The reaction of the cerebral cortex to chronically implanted plastic needles.
Stensaas, S. S., & Stensaas, L. J. (1976) · PubMed · Cited by 88
Biocompatibility of layer-by-layer self-assembled nanofilm on silicone rubber for neurons
Ai, H., Meng, H., Ichinose, I., Jones, S. A., Mills, D. K., LVOV, Y. M., & Qiao, X. (2003) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(03)00191-2 · Cited by 88
Ultrafast resorbing polymers for use as carriers for cortical neural probes
Lewitus, D. Y., Smith, K. L., Shain, W. G., & Kohn, J. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.02.027 · Cited by 86
Microporous conducting polymers on neural microelectrode arrays
Yang, J., & Martin, D. C. (2004) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2004.02.056 · Cited by 84
McClelland, R., Wauthier, E., Uronis, J., & Reid, L. M. (2008) · Tissue Engineering Part A · doi:10.1089/ten.a.2007.0058 · Cited by 84
Evaluation of the stability of intracortical microelectrode arrays
Liu, X., McCreery, D. B., Bullara, L. A., & Agnew, W. F. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.870495 · Cited by 84
Galimberti, D., Baron, P., Meda, L., Prat, E., Scarpini, E., Delgado, R., Catania, A., Lipton, J. M., & Scarlato, G. (1999) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.1999.1276 · Cited by 83
Seitz, R. J., Heininger, K., Schwendemann, G., Toyka, K. V., & Wechsler, W. (1985) · Acta Neuropathologica · doi:10.1007/bf00688950 · Cited by 81
Biocompatible benzocyclobutene (BCB)-based neural implants with micro-fluidic channel
Lee, K., He, J., Clement, R. S., Massia, S. P., & Kim, B. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.02.005 · Cited by 78
Controlled release nanoparticle-embedded coatings reduce the tissue reaction to neuroprostheses
Mercanzini, A., Reddy, S. T., Velluto, D., Colin, P., Maillard, A., Bensadoun, J., Hubbell, J. A., & Renaud, P. (2010) · Journal of Controlled Release · doi:10.1016/j.jconrel.2010.04.025 · Cited by 78
Warren, D. J., Fernandez, E., & Normann, R. A. (2001) · Neuroscience · doi:10.1016/s0306-4522(01)00174-9 · Cited by 77
Flexible carbon nanotubes electrode for neural recording
Lin, C.-M., Lee, Y., Yeh, S., & Fang, W. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.02.005 · Cited by 77
Study of functional viability of SU-8-based microneedles for neural applications
Fernández, L. J., Altuna, A., Tijero, M., Gabriel, G., Villa, R., Rodríguez, M. J., Batlle, M., Vilares, R., Berganzo, J., & Blanco, F. J. (2009) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/19/2/025007 · Cited by 76
Seven years of recording from monkey cortex with a chronically implanted multiple microelectrode
Krüger, J. (2010) · Frontiers in Neuroengineering · doi:10.3389/fneng.2010.00006 · Cited by 75
A 3D glass optrode array for optical neural stimulation
Abaya, T. V. F., Blair, S., Tathireddy, P., Rieth, L. W., & Solzbacher, F. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.003087 · Cited by 75
Micropatterning of Nanoengineered Surfaces to Study Neuronal Cell Attachment in Vitro
Mohammed, J. S., DeCoster, M. A., & McShane, M. J. (2004) · Biomacromolecules · doi:10.1021/bm0498631 · Cited by 73
Webb, K. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00353-7 · Cited by 73
Mandal, H. S., Knaack, G. L., Charkhkar, H., McHail, D. G., Kastee, J. S., Dumas, T. C., Peixoto, N., Rubinson, J. F., & Pancrazio, J. J. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.02.029 · Cited by 72
Astrocyte responses to injury: VEGF simultaneously modulates cell death and proliferation
Schmid-Brunclik, N., Taboada, C. B., Antoniou, X., Gassmann, M., & Ogunshola, O. O. (2008) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00536.2007 · Cited by 71
A wafer-scale etching technique for high aspect ratio implantable MEMS structures
Bhandari, R., Negi, S., Rieth, L., & Solzbacher, F. (2010) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2010.06.011 · Cited by 71
Aihara, N., Tanno, H., Hall, J. J., Pitts, L. H., & Noble‐Haeusslein, L. J. (1994) · The Journal of Comparative Neurology · doi:10.1002/cne.903420402 · Cited by 71
Bioactive properties of nanostructured porous silicon for enhancing electrode to neuron interfaces
Moxon, K. A., Hallman, S. J., Aslani, A., Kalkhoran, N. M., & Lelkes, P. I. (2007) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856207782177882 · Cited by 69
Histopathological Changes Produced by Implanted Electrodes in Cat Brains
Collias, J. C., & Manuelidis, E. E. (1957) · Journal of neurosurgery · doi:10.3171/jns.1957.14.3.0302 · Cited by 68
Potter, K. A., Simon, J. S., Velagapudi, B., & Capadona, J. R. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2011.09.024 · Cited by 68
Self-citationStainless Steel Micro-Needle Electrodes Made by Electrolytic Pointing
Grundfest, H., Sengstaken, R. W., Oettinger, W. H., & Gurry, R. W. (1950) · Review of Scientific Instruments · doi:10.1063/1.1745583 · Cited by 68
Hynds, D. L., & Snow, D. M. (1999) · Experimental Neurology · doi:10.1006/exnr.1999.7212 · Cited by 68
The challenge of integrating devices into the central nervous system.
Tresco, P. A., & Winslow, B. D. (2011) · Critical Reviews™ in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v39.i1.30 · Cited by 65
An ultra-compliant, scalable neural probe with molded biodissolvable delivery vehicle
Gilgunn, P. J., Khilwani, R., Kozai, T. D. Y., Weber, D. J., Cui, X. T., Erdös, G., Özdoğanlar, O. B., & Fedder, G. K. (2012) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2012.6170092 · Cited by 65
Cellular response to low adhesion nanotopographies.
Dalby, M. J. (2007) · PubMed Central · Cited by 64
The role of methane in mammalian physiology—is it a gasotransmitter?
Boros, M., Tuboly, E., Mészáros, A., & Amann, A. (2015) · Journal of Breath Research · doi:10.1088/1752-7155/9/1/014001 · Cited by 64
Neural Interfaces at The Nanoscale
Pancrazio, J. J. (2008) · Nanomedicine · doi:10.2217/17435889.3.6.823 · Cited by 64
Brain tissue reaction to permselective polymer capsules
Winn, S. R., Aebischer, P., & Galletti, P. M. (1989) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820230104 · Cited by 64
Mechanisms of fibrinogen domains : biomaterial interactions
Tang, L. (1998) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856298x00370 · Cited by 63
The ultrastructure of the sheath around chronically implanted electrodes in brain
Schultz, R. L., & Willey, T. J. (1976) · Journal of Neurocytology · doi:10.1007/bf01181577 · Cited by 63
Nanomaterials for Application in Medicine and Biology
Giersig, M., & NATO. (2008) · NATO science for peace and security series. B, Physics and biophysics · doi:10.1007/978-1-4020-6829-4 · Cited by 63
Gopalakrishnan, S. M., Teusch, N., Imhof, C., Bakker, M. H. M., Schurdak, M., Burns, D. J., & Warrior, U. (2008) · Journal of Neuroscience Research · doi:10.1002/jnr.21671 · Cited by 62
A new chronic recording intracortical microelectrode
Salcman, M., & Bak, M. J. (1976) · Medical & Biological Engineering & Computing · doi:10.1007/bf02477088 · Cited by 61
Skousen, J. L., Bridge, M. J., & Tresco, P. A. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2014.08.039 · Cited by 61
Self-citationDesign, Fabrication, and In Vivo Behavior of Chronic Recording Intracortical Microelectrodes
Salcman, M., & Bak, M. J. (1973) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1973.324189 · Cited by 60
Kolarcik, C. L., Bourbeau, D., Azemi, E., Rost, E., Zhang, L., Lagenaur, C. F., Weber, D. J., & Cui, X. T. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.06.034 · Cited by 59
A novel method of fabricating convoluted shaped electrode arrays for neural and retinal prostheses
Bhandari, R., Negi, S., Rieth, L. W., Normann, R. A., & Solzbacher, F. (2007) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2007.10.072 · Cited by 59
Nakanishi, K., Aono, S., Hirano, K., Kuroda, Y., Ida‐Eto, M., Tokita, Y., Matsui, F., & Oohira, A. (2006) · Journal of Biological Chemistry · doi:10.1074/jbc.m601498200 · Cited by 58
The isolation of cell derived extracellular matrix constructs using sacrificial open-cell foams
Wolchok, J. C., & Tresco, P. A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.08.072 · Cited by 58
Polymer micro piezo valve with a small dead volume
Shao, P., Rummler, Z., & Schomburg, W. K. (2003) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/2/020 · Cited by 57
Host response to microgel coatings on neural electrodes implanted in the brain
Gutowski, S. M., Templeman, K. L., South, A. B., Gaulding, J. C., Shoemaker, J. T., LaPlaca, M. C., Bellamkonda, R. V., Lyon, L. A., & Garcı́a, A. J. (2013) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34799 · Cited by 57
SU‐8 2000 rendered cytocompatible for neuronal bioMEMS applications
Vernekar, V. N., Cullen, D. K., Fogleman, N., Choi, Y., García, A. J., Allen, M. G., Brewer, G. J., & LaPlaca, M. C. (2009) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31839 · Cited by 57
The Electrochemistry of Charge Injection at the Electrode/Tissue Interface
Merrill, D. R. (2010) · Biological and medical physics series · doi:10.1007/978-0-387-98120-8_4 · Cited by 56
Recording for several days from single cortical neurons in completely unrestrained cats
Burns, B. D., Stean, J. P. B., & Webb, A. C. (1974) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(74)90175-8 · Cited by 56
Potter–Baker, K. A., Nguyen, J. K., Kovach, K. M., Gitomer, M. M., Srail, T. W., Stewart, W. G., Skousen, J. L., & Capadona, J. R. (2014) · Journal of Materials Chemistry B · doi:10.1039/c4tb00125g · Cited by 55
Self-citationEvaluation of silicon nanoporous membranes and ECM-based microenvironments on neurosecretory cells
A, C. A. L., Fleischman, A. J., Roy, S., & Desai, T. A. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.12.017 · Cited by 54
Mechanical factors in the design of chronic recording intracortical microelectrodes
Goldstein, S. R., & Salcman, M. (1973) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1973.324190 · Cited by 53
McConnell, G. C., Schneider, T. M., Owens, D. J., & Bellamkonda, R. V. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.895373 · Cited by 53
An active, flexible carbon nanotube microelectrode array for recording electrocorticograms
Chen, Y., Hsu, H., Lee, Y., Su, H., Yen, S., Chen, C., Hsu, W.-L., Yew, T., Yeh, S., Yao, D., et al. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/034001 · Cited by 52
Tanaka, J., Toku, K., Sakanaka, M., & Maeda, N. (1999) · Neuroscience Research · doi:10.1016/s0168-0102(99)00041-3 · Cited by 50
Robust penetrating microelectrodes for neural interfaces realized by titanium micromachining
McCarthy, P. T., Otto, K. J., & Rao, M. P. (2011) · Biomedical Microdevices · doi:10.1007/s10544-011-9519-5 · Cited by 50
Nanopatterning effects on astrocyte reactivity
Ereifej, E. S., Matthew, H. W. T., Newaz, G. M., Mukhopadhyay, A., Auner, G. W., Salakhutdinov, I. F., & VandeVord, P. J. (2012) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34480 · Cited by 49
Gregerson, D. S., Sam, T. N., & McPherson, S. W. (2004) · The Journal of Immunology · doi:10.4049/jimmunol.172.11.6587 · Cited by 48
Characterization of a 3D optrode array for infrared neural stimulation
Abaya, T. V. F., Diwekar, M., Blair, S., Tathireddy, P., Rieth, L. W., Clark, G. A., & Solzbacher, F. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.002200 · Cited by 48
Monocyte:astrocyte interactions regulate MCP-1 expression in both cell types
Andjelkovic, A. V., Kerkovich, D. M., & Pachter, J. S. (2000) · Journal of Leukocyte Biology · doi:10.1189/jlb.68.4.545 · Cited by 47
Ravikumar, M., Hageman, D. J., Tomaszewski, W. H., Chandra, G. M., Skousen, J. L., & Capadona, J. R. (2013) · Journal of Materials Chemistry B · doi:10.1039/c3tb21453b · Cited by 46
Self-citationElectrophysiological Mapping of Cat Primary Auditory Cortex with Multielectrode Arrays
Kim, S.-J., Manyam, S. C., Warren, D. J., & Normann, R. A. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-9037-9 · Cited by 45
A comparison of neuroinflammation to implanted microelectrodes in rat and mouse models
Potter–Baker, K. A., Ravikumar, M., Burke, A., Meador, W. D., Householder, K. T., Buck, A. C., Sunil, S., Stewart, W. G., Anna, J. P., Tomaszewski, W. H., et al. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.03.076 · Cited by 45
Self-citationCELL AND EXTRACELLULAR MATRIX REJECTION IN ARTERIAL CONCORDANT AND DISCORDANT XENOGRAFTS IN THE RAT1
Allaire, É., Mandet, C., Bruneval, P., Bensenane, S., Becquemin, J., & Michel, J. (1996) · Transplantation · doi:10.1097/00007890-199609270-00017 · Cited by 45
Girbovan, C., Morin, L., & Plamondon, H. (2011) · Behavioural Pharmacology · doi:10.1097/fbp.0b013e32834eafa3 · Cited by 43
A Novel Dexamethasone-releasing, Anti-inflammatory Coating for Neural Implants
Zhong, Y., McConnell, G. C., Ross, J. D. C., DeWeerth, S. P., & Bellamkonda, R. V. (2005) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2005.1419674 · Cited by 39
An organotypic spinal cord slice culture model to quantify neurodegeneration
Ravikumar, M., Jain, S., Miller, R. H., Capadona, J. R., & Selkirk, S. M. (2012) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2012.09.004 · Cited by 38
Self-citationIn Vivo Biostability of CVD Silicon Oxide and Silicon Nitride Films
Maloney, J. M., Lipka, S. A., & Baldwin, S. P. (2005) · MRS Proceedings · doi:10.1557/proc-872-j14.3 · Cited by 38
AZZI, G., Bernaudin, J., Bouchaud, C., Bellon, B., & Fleury‐Feith, J. (1990) · Biology of the Cell · doi:10.1111/j.1768-322x.1990.tb00890.x · Cited by 37
Flexible UV‐Ozone‐Modified Carbon Nanotube Electrodes for Neuronal Recording
Hsu, H., Teng, I., Chen, Y., Hsu, W., Lee, Y., Yen, S., Su, H., Yeh, S., Chen, H., & Yew, T. (2010) · Advanced Materials · doi:10.1002/adma.200903413 · Cited by 36
Betjes, M. G. H., Tuk, C. W., Struijk, D. G., Krediet, R. T., Arisz, L., & Beelen, R. H. J. (1993) · Clinical & Experimental Immunology · doi:10.1111/j.1365-2249.1993.tb03460.x · Cited by 36
Activity of single action potentials in monkey motor cortex during long-term task learning
Kennedy, P. R., & Bakay, R. A. E. (1997) · Brain Research · doi:10.1016/s0006-8993(97)00051-6 · Cited by 34
Ischemic Neuronal Injury is Ameliorated by Astrocyte Activation
Louw, D. F., Masada, T., & Sutherland, G. R. (1998) · Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques · doi:10.1017/s0317167100033692 · Cited by 34
Sub-meninges implantation reduces immune response to neural implants
Markwardt, N. T., Stokol, J., & Rennaker, R. L. (2013) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2013.01.020 · Cited by 33
Neuroprosthetic devices: how far are we from recovering movement in paralyzed patients?
Pancrazio, J. J., & Peckham, P. H. (2009) · Expert Review of Neurotherapeutics · doi:10.1586/ern.09.12 · Cited by 32
Sommakia, S., Gaire, J., Rickus, J. L., & Otto, K. J. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00033 · Cited by 32
Hassanabadi, H. M., & Rodrigue, D. (2011) · Rheologica Acta · doi:10.1007/s00397-011-0603-9 · Cited by 31
Preliminary Study of Multichannel Flexible Neural Probes Coated with Hybrid Biodegradable Polymer
Kato, Y. X., Saito, I., Hoshino, T., Suzuki, T., & Mabuchi, K. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.259978 · Cited by 31
Lewitus, D. Y., Vogelstein, R. J., Zhen, G., Choi, Y.-S., Kohn, J., Harshbarger, S. D., & Jia, X. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2098047 · Cited by 30
The fate of ultrafast degrading polymeric implants in the brain
Lewitus, D. Y., Smith, K. L., Shain, W. G., Bolikal, D., & Kohn, J. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.04.052 · Cited by 28
Bioactive anti‐inflammatory coating for chronic neural electrodes
Taub, A. H., Hogri, R., Magal, A., Mintz, M., & Shacham‐Diamand, Y. (2012) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34152 · Cited by 28
TLR4 and HMGB1: partners in crime?
Goligorsky, M. S. (2011) · Kidney International · doi:10.1038/ki.2011.170 · Cited by 27
Guénard, V., Frisch, G., & Wood, P. M. (1996) · Experimental Neurology · doi:10.1006/exnr.1996.0017 · Cited by 25
Surface‐Nucleated Assembly of Fibrillar Extracellular Matrices
Capadona, J. R., Petrie, T. A., Fears, K. P., Latour, R. A., Collard, D. M., & García, A. J. (2005) · Advanced Materials · doi:10.1002/adma.200500959 · Cited by 25
Self-citationParylene microprobes with engineered stiffness and shape for improved insertion
Egert, D., Peterson, R. L., & Najafi, K. (2011) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2011.5969352 · Cited by 24
(2012) · Elsevier eBooks · doi:10.1016/c2010-0-67866-7 · Cited by 24
Biomechanical Strain Analysis at the Interface of Brain and Nanowire Electrodes on a Neural Probe
Zhu, R., Huang, G. L., Yoon, H., Smith, C. S., & Varadan, V. K. (2011) · Journal of Nanotechnology in Engineering and Medicine · doi:10.1115/1.4005484 · Cited by 23
Extracellular matrix-based materials for neural interfacing
Chen, S., & Allen, M. G. (2012) · MRS Bulletin · doi:10.1557/mrs.2012.120 · Cited by 23
Signal acquisition and analysis for cortical control of neuroprosthetics
Tillery, S. I. H., & Taylor, D. M. (2004) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2004.10.013 · Cited by 22
Repair of the blood-brain barrier following implantation of polymer capsules
Jaeger, C. B., Winn, S. R., Tresco, P. A., & Aebischer, P. (1991) · Brain Research · doi:10.1016/0006-8993(91)90929-p · Cited by 22
Subbaroyan, J., & Kipke, D. R. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.260517 · Cited by 21
Kuffler, D. P., Sosa, I. J., & Reyes, O. (2009) · Journal of Neuroscience Research · doi:10.1002/jnr.22132 · Cited by 20
Assessment of subdural insertion force of single-tine microelectrodes in rat cerebral cortex
Jensen, W., Hofmann, U., & Yoshida, K. (2004) · doi:10.1109/iembs.2003.1280170 · Cited by 20
Defined adhesion and growth of neurones on artificial structured substrates
Heiduschka, P., Romann, I., Ecken, H., Schöning, M. J., Schuhmann, W. W., & Thanos, S. (2001) · Electrochimica Acta · doi:10.1016/s0013-4686(01)00573-4 · Cited by 20
A bio-inspired, chemo-responsive polymer nanocomposite for mechanically dynamic microsystems
Hess‐Dunning, A., Dunning, J. L., Harris, J. P., Capadona, J. R., Shanmuganathan, K., Rowan, S. J., Weder, C., Tyler, D. J., & Zorman, C. A. (2009) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.2009.5285522 · Cited by 20
Self-citationLudwig, K. A., Miriani, R. M., Langhals, N. B., Marzullo, T., & Kipke, D. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/049801 · Cited by 19
A dynamic view of the blood–brain barrier in active multiple sclerosis lesions
Lassmann, H. (2011) · Annals of Neurology · doi:10.1002/ana.22494 · Cited by 18
Kim, Y. T., Bridge, M. J., & Tresco, P. A. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2007.01.002 · Cited by 16
Wang, A., Liang, X., McAllister, J. P., Li, J., Brabant, K., Black, C., Finlayson, P. G., Cao, T., Tang, H., Salley, S. O., et al. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31034 · Cited by 16
A graphene-based microelectrode for recording neural signals
Chen, C., Lin, C., Chen, J. J., Hsu, W. L., Chang, Y., Yeh, S. R., Li, L. J., & Yao, D. J. (2011) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2011.5969794 · Cited by 16
Smart Structures and Materials 2004: Smart Electronics, MEMS, BioMEMS, and Nanotechnology
Varadan, V. K. (2004) · Cited by 16
Carbon nanotube integration into MEMS devices
Hanein, Y. (2010) · physica status solidi (b) · doi:10.1002/pssb.201000109 · Cited by 14
Monitoring Insertion Force and Electrode Impedance during Implantation of Microwire Electrodes
Tian, C., & He, J. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1616205 · Cited by 13
Bioactive conducting polymers for neural interfaces application to vision prosthesis
Green, R. A., Suaning, G. J., Poole-Warren, L. A., & Lovell, N. H. (2009) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2009.5109234 · Cited by 13
Hammer, D. X., Lozzi, A., Boretsky, A. R., & Welle, C. G. (2016) · Neurophotonics · doi:10.1117/1.nph.3.2.025002 · Cited by 13
Classification of spoken words using surface local field potentials
Kellis, S., Miller, K. J., Thomson, K., Brown, R. B., House, P., & Greger, B. E. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5627682 · Cited by 11
Reichert, W. M. (2008) · Cited by 10
Mozafari, M. R. (2007) · Cited by 10
Hess‐Dunning, A., Potter, K. A., Tyler, D. J., Zorman, C. A., & Capadona, J. R. (2013) · Journal of Visualized Experiments · doi:10.3791/50078 · Cited by 9
Self-citationBenzocyclobutene (BCB) based neural implants with microfluidic channel
Lee, K., He, J., & Wang, L. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1404204 · Cited by 6
Harris, J. P. (2011) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 5
In Vivo Solute Diffusivity in Brain Tissue Surrounding Indwelling Neural Implants
Bridge, M. J., & Tresco, P. A. (2007) · Frontiers in neuroengineering series/Frontiers in neuroengineering · doi:10.1201/9781420009309.ch5 · Cited by 3
Clement, R. S., Singh, A., Olson, B., Lee, K., & He, J. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1280172 · Cited by 3
Kim, J. W., Choi, S. H., Lillehei, P. T., King, G. C., Watt, G. D., Chu, S., Park, Y., & Thibeault, S. A. (2004) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.539268 · Cited by 2
Subbaroyan, J. (2007) · Deep Blue (University of Michigan) · Cited by 2
Research works printed but not linked: 32
- Kellis S, 2010, Conf. Proc. IEEE Eng. Med. Biol. Soc., 2010, 3827
- Kruger J, 2010, Front. Neuroeng., 3, 6
- Prasad A, 2012, J. Neural. Eng., 9
- Wark H A C, 2013, J. Neural. Eng., 10
- Hanson S R, 1980, J. Lab. Clin. Med., 95, 289
- Pollock A L, 2007, Early Brain Tissue Reaction Surrounding the Michigan-Style Microelectrode Arrays Indicates that Extensive Remodeling of Glial and Neuronal Populations Occurs During the Foreign Body Response
- Harris J P, 2011, J. Neural. Eng., 8
- Hess A E, 2013, JoVE, 78
- Harris J P, 2011, J. Neural. Eng., 8
- Chao C C, 1995, Crit. Rev. Neurobiol., 9, 189
- Feuerstein G Z, 1994, Cerebrovasc. Brain Metab. Rev., 6, 341
- Skousen M B J L, 2014, Biomaterials
- Stensaas S S, 1976, Acta Neuropathol (Berl), 35, 187
- McConnell G C, 2009, J. Neural Eng., 6
- Harris J P, 2011, Dissertation
- Jensen W, 2003, 2003 Proc. of the 25th Annual Int. Conf. of the IEEE
- Egert D, 2011, 16th Int. Conf. on Actuators and Microsystems 5–9 June (Beijing), 198
- ChunXiang T, 2005, 27th Annual Int. Conf. of the IEEE-EMBS
- Zhu R Y H, 2012, J. Nanotechnology Eng. Med, 2
- Subbaroyan J, 2006, Conf. Proc. IEEE Eng. Med. Biol. Soc.
- Clement R S, 2003, Proc. 25th Annual Int. Conf. of the IEEE EMBS (Cancun, Mexico)
- Lee K, 2004, P. Ann Int. IEEE Embs., 26, 4326
- Kato Y, 2006, Proc. IEEE, 1-15, 5444
- Kim D-H, 2010, Nat. Mater
- Nguyen J K, 2014, J. Neural. Eng., 11
- Dalby M J, 2007, Int. J. Nanomed., 2, 373
- Azemi E, 2008, Acta Biomater.
- Green R A, 2009, 4th Int. IEEE/EMBS Conf. on Neural Engineering
- Indwelling Neural Implants, 2008, Strategies for Contending with the In vivo Environment
- Voge C M, 2011, J. Neural. Eng., 8
- Hanein Y, 2013, Front. Neural Circuits, 6
- Chen Y-C, 2011, J. Neural. Eng., 8
Cited by
Sorted by citations
A review of the volatiles from the healthy human body
de Lacy Costello, B., Amann, A., Al-Kateb, H., Flynn, C., Filipiak, W., Khalid, T., Osborne, D., & Ratcliffe, N. M. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/1/014001 · Cited by 1,042
Ajiboye, A. B., Willett, F. R., Young, D. R., Memberg, W. D., Murphy, B. A., Miller, J. P., Walter, B. L., Sweet, J. A., Hoyen, H. A., Keith, M. W., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30601-3 · Cited by 862
Amann, A., Costello, B. D. L., Miekisch, W., Schubert, J., Buszewski, B., Pleil, J., Ratcliffe, N., & Risby, T. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/3/034001 · Cited by 804
Recent advances in nanocellulose for biomedical applications
Jorfi, M., & Foster, E. J. (2014) · Journal of Applied Polymer Science · doi:10.1002/app.41719 · Cited by 737
Self-citationMaterials and technologies for soft implantable neuroprostheses
Lacour, S. P., Courtine, G., & Guck, J. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.63 · Cited by 738
Metadata
- Authors
- Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R.
- Affiliations
- University of Fribourg (CH)
- University of Utah (US)
- Louis Stokes Cleveland VA Medical Center (US)
- Corresponding author
- Capadona, Jeffrey R
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2014-12-02
- Volume
- 12
- Issue
- 1
- Pages
- 011001
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- PMC
- PMC4428498
- OpenAlex
- W2056731994
- Cited by
- 384
- References
- 376
- Citations by year
- 2026: 12 · 2025: 26 · 2024: 20 · 2023: 29 · 2022: 31 · 2021: 36 · 2020: 39 · 2019: 33 · 2018: 43 · 2017: 51 · 2016: 27 · 2015: 20 · 2014: 11
- FWCI
- 4.15
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- U.S. Department of Veterans Affairs (B1495-R, PECASE, B7122R)
- National Institute of Neurological Disorders and Stroke (1R01NS082404-01A1)
- Swiss National Science Foundation (NRP 62: Smart Materials, Nr. 406240_126046)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- intracortical microelectrodes, neural interfaces, neuroinflammation, biocompatibility, long-term neural recording, compliant materials, conducting polymers, nanomaterials, bioactive compounds, electrode materials
- MeSH terms
- Action Potentials, Brain, Electrodes, Implanted, Electroencephalography, Equipment Design, Microelectrodes, Neurons, Equipment Failure Analysis, Coated Materials, Biocompatible, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review