Rapid evaluation of the durability of cortical neural implants using accelerated aging with reactive oxygen species
Open accessThe DOI matches its Crossref record; 71 of the 71 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: A challenge for implementing high bandwidth cortical brain-machine interface devices in patients is the limited functional lifespan of implanted recording electrodes. Development of implant technology currently requires extensive non-clinical testing to demonstrate device performance. However, testing the durability of the implants in vivo is time-consuming and expensive. Validated in vitro methodologies may reduce the need for extensive testing in animal models. APPROACH: Here we describe an in vitro platform for rapid evaluation of implant stability. We designed a reactive accelerated aging (RAA) protocol that employs elevated temperature and reactive oxygen species (ROS) to create a harsh aging environment. Commercially available microelectrode arrays (MEAs) were placed in a solution of hydrogen peroxide at 87 °C for a period of 7 days. We monitored changes to the implants with scanning electron microscopy and broad spectrum electrochemical impedance spectroscopy (1 Hz-1 MHz) and correlated the physical changes with impedance data to identify markers associated with implant failure. MAIN RESULTS: RAA produced a diverse range of effects on the structural integrity and electrochemical properties of electrodes. Temperature and ROS appeared to have different effects on structural elements, with increased temperature causing insulation loss from the electrode microwires, and ROS concentration correlating with tungsten metal dissolution. All array types experienced impedance declines, consistent with published literature showing chronic (>30 days) declines in array impedance in vivo. Impedance change was greatest at frequencies <10 Hz, and smallest at frequencies 1 kHz and above. Though electrode performance is traditionally characterized by impedance at 1 kHz, our results indicate that an impedance change at 1 kHz is not a reliable predictive marker of implant degradation or failure. SIGNIFICANCE: ROS, which are known to be present in vivo, can create structural damage and change electrical properties of MEAs. Broad-spectrum electrical impedance spectroscopy demonstrates increased sensitivity to electrode damage compared with single-frequency measurements. RAA can be a useful tool to simulate worst-case in vivo damage resulting from chronic electrode implantation, simplifying the device development lifecycle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
NIH Image to ImageJ: 25 years of image analysis
Schneider, C. A., Rasband, W. S., & Eliceiri, K. W. (2012) · Nature Methods · doi:10.1038/nmeth.2089 · Cited by 64,638
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Reactive Oxygen Species and the Central Nervous System
Halliwell, B. (1992) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1992.tb10990.x · Cited by 2,947
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848
Hydrogen peroxide: a metabolic by-product or a common mediator of ageing signals?
Giorgio, M., Trinei, M., Migliaccio, E., & Pelicci, P. G. (2007) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2240 · Cited by 1,447
Colorimetric Determination of Hydrogen Peroxide
Eisenberg, G. (1943) · Industrial & Engineering Chemistry Analytical Edition · doi:10.1021/i560117a011 · Cited by 1,295
Active Oxygen Species and the Functions of Phagocytic Leukocytes
Badwey, J. A., & Karnovsky, M. L. (1980) · Annual Review of Biochemistry · doi:10.1146/annurev.bi.49.070180.003403 · Cited by 1,114
Brain–Computer InterfacesPrinciples and Practice
Wolpaw, J., & Wolpaw, E. W. (2012) · Oxford University Press eBooks · doi:10.1093/acprof:oso/9780195388855.001.0001 · Cited by 1,104
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
Brain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S., Spence, A. J., Isaacson, M., Craighead, H. G., Turner, J. N., & Shain, W. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 796
Kozai, T. D. Y., Langhals, N. B., Patel, P. R., Deng, X., Zhang, H., Smith, K. L., Lahann, J., Kotov, N. A., & Kipke, D. R. (2012) · Nature Materials · doi:10.1038/nmat3468 · Cited by 721
A high-performance brain–computer interface
Santhanam, G., Ryu, S. I., Yu, B. M., Afshar, A., & Shenoy, K. V. (2006) · Nature · doi:10.1038/nature04968 · Cited by 698
Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646
Ludwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638
Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates
Barrese, J. C., Rao, N., Paroo, K., Triebwasser, C., Vargas-Irwin, C., Franquemont, L., & Donoghue, J. P. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066014 · Cited by 600
Direct neural sensory feedback and control of a prosthetic arm
Dhillon, G. S., & Horch, K. W. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.856072 · Cited by 573
Simeral, J. D., Kim, S.-P., Black, M. J., Donoghue, J. P., & Hochberg, L. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025027 · Cited by 496
McConnell, G. C., Rees, H. D., Levey, A. I., Gutekunst, C.-A., Gross, R. E., & Bellamkonda, R. V. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/5/056003 · Cited by 480
Chronic Neural Recording Using Silicon-Substrate Microelectrode Arrays Implanted in Cerebral Cortex
Vetter, R. J., Williams, J. C., Hetke, J. F., Nunamaker, E. A., & Kipke, D. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826680 · Cited by 475
Neural probe design for reduced tissue encapsulation in CNS
Seymour, J. P., & Kipke, D. R. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.024 · Cited by 462
Complex impedance spectroscopy for monitoring tissue responses to inserted neural implants
Williams, J. C., Hippensteel, J. A., Dilgen, J., Shain, W., & Kipke, D. R. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/4/007 · Cited by 399
Kim, S.-P., Simeral, J. D., Hochberg, L. R., Donoghue, J. P., & Black, M. J. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/4/010 · Cited by 397
Electrical properties of implant encapsulation tissue
Grill, W. M., & Thomas Mortimer, J. (1994) · Annals of Biomedical Engineering · doi:10.1007/bf02368219 · Cited by 376
Chestek, C. A., Gilja, V., Nuyujukian, P., Foster, J. D., Fan, J. M., Kaufman, M. T., Churchland, M. M., Rivera-Alvidrez, Z., Cunningham, J. P., Ryu, S. I., et al. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/045005 · Cited by 350
Long-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve
Branner, A., Stein, R. B., Fernandez, E., Aoyagi, Y., & Normann, R. A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820321 · Cited by 301
Prasad, A., Xue, Q.-S., Sankar, V., Nishida, T., Shaw, G., Streit, W. J., & Sanchez, J. C. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/5/056015 · Cited by 298
Toward a comparison of microelectrodes for acute and chronic recordings
Ward, M. P., Rajdev, P., Ellison, C., & Irazoqui, P. P. (2009) · Brain Research · doi:10.1016/j.brainres.2009.05.052 · Cited by 296
Ludwig, K. A., Langhals, N. B., Joseph, M. D., Richardson-Burns, S. M., Hendricks, J. L., & Kipke, D. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/1/014001 · Cited by 283
The impact of chronic blood–brain barrier breach on intracortical electrode function
Saxena, T., Karumbaiah, L., Gaupp, E. A., Patkar, R., Patil, K., Betancur, M., Stanley, G. B., & Bellamkonda, R. V. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.03.007 · Cited by 266
Accelerated aging for testing polymeric biomaterials and medical devices
Hukins, D. W. L., Mahomed, A., & Kukureka, S. N. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.06.001 · Cited by 247
Relationship between intracortical electrode design and chronic recording function
Karumbaiah, L., Saxena, T., Carlson, D., Patil, K., Patkar, R., Gaupp, E. A., Betancur, M., Stanley, G. B., Carin, L., & Bellamkonda, R. V. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.07.016 · Cited by 241
Long-term implants of Parylene-C coated microelectrodes
Schmidt, E. M., Mcintosh, J. S., & Bak, M. J. (1988) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441836 · Cited by 234
In vivo impedance spectroscopy of deep brain stimulation electrodes
Lempka, S. F., Miocinovic, S., Johnson, M. D., Vitek, J. L., & McIntyre, C. C. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/4/046001 · Cited by 229
Spataro, L., Dilgen, J., Retterer, S., Spence, A. J., Isaacson, M., Turner, J. N., & Shain, W. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2004.08.037 · Cited by 215
Mechanisms of polymer degradation in implantable devices
Ali, S. A. M., Zhong, S.-P., Doherty, P. J., & Williams, D. F. (1993) · Biomaterials · doi:10.1016/0142-9612(93)90063-8 · Cited by 208
Diffusion barriers evoked in the rat cortex by reactive astrogliosis
Roitbak, T., & Sykov�, E. (1999) · Glia · doi:10.1002/(sici)1098-1136(199910)28:1<40::aid-glia5>3.0.co;2-6 · Cited by 207
Implant Size and Fixation Mode Strongly Influence Tissue Reactions in the CNS
Thelin, J., Jörntell, H., Psouni, E., Garwicz, M., Schouenborg, J., Danielsen, N., & Linsmeier, C. E. (2011) · PLoS ONE · doi:10.1371/journal.pone.0016267 · Cited by 191
Highly reactive oxygen species: detection, formation, and possible functions
Freinbichler, W., Colivicchi, M. A., Stefanini, C., Bianchi, L., Ballini, C., Misini, B., Weinberger, P., Linert, W., Varešlija, D., Tipton, K. F., et al. (2011) · Cellular and Molecular Life Sciences · doi:10.1007/s00018-011-0682-x · Cited by 181
Model-based analysis of cortical recording with silicon microelectrodes
Moffitt, M. A., & McIntyre, C. C. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.05.018 · Cited by 170
Corrosion of tungsten microelectrodes used in neural recording applications
Patrick, E., Orazem, M. E., Sanchez, J. C., & Nishida, T. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2011.03.012 · Cited by 167
Fabrication of Responsive, Softening Neural Interfaces
Ware, T., Simon, D., Arreaga‐Salas, D. E., Reeder, J., Rennaker, R., Keefer, E. W., & Voit, W. (2012) · Advanced Functional Materials · doi:10.1002/adfm.201200200 · Cited by 165
Quantifying long-term microelectrode array functionality using chronic in vivo impedance testing
Prasad, A., & Sanchez, J. C. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/2/026028 · Cited by 157
The insulation performance of reactive parylene films in implantable electronic devices
Seymour, J. P., Elkasabi, Y. M., Chen, H.-Y., Lahann, J., & Kipke, D. R. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.07.061 · Cited by 147
Tien, L. W., Wu, F., Tang‐Schomer, M. D., Yoon, E., Omenetto, F. G., & Kaplan, D. L. (2013) · Advanced Functional Materials · doi:10.1002/adfm.201203716 · Cited by 136
In Vivo Electrical Impedance Spectroscopy of Tissue Reaction to Microelectrode Arrays
Mercanzini, A., Colin, P., Bensadoun, J.-C., Bertsch, A., & Renaud, P. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2018457 · Cited by 130
Long-term chronic recording from cortical neurons
Schmidt, E. M., Bak, M. J., & McIntosh, J. S. (1976) · Experimental Neurology · doi:10.1016/0014-4886(76)90220-x · Cited by 127
Skousen, J. L., Merriam, S. M. E., Srivannavit, O., Perlin, G., Wise, K. D., & Tresco, P. A. (2011) · Progress in Brain Research · doi:10.1016/b978-0-444-53815-4.00009-1 · Cited by 111
Peer Reviewed: Color Images for Fast-Scan CV Measurements in Biological Systems
Michael, D., Travis, E. R., & Wightman, R. M. (1998) · Analytical Chemistry · doi:10.1021/ac9819640 · Cited by 111
Neurotrophic electrode: Method of assembly and implantation into human motor speech cortex
Bartels, J., Andreasen, D., Ehirim, P., Mao, H., Seibert, S., Wright, E. J., & Kennedy, P. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.06.030 · Cited by 108
Human cortical prostheses: lost in translation?
Ryu, S. I., & Shenoy, K. V. (2009) · Neurosurgical Focus · doi:10.3171/2009.4.focus0987 · Cited by 104
The density difference between tissue and neural probes is a key factor for glial scarring
Lind, G., Linsmeier, C. E., & Schouenborg, J. (2013) · Scientific Reports · doi:10.1038/srep02942 · Cited by 102
Neural machine interfaces for controlling multifunctional powered upper-limb prostheses
Ohnishi, K., Weir, R. F., & Kuiken, T. A. (2007) · Expert Review of Medical Devices · doi:10.1586/17434440.4.1.43 · Cited by 102
Extracellular Single-Unit Recording Methods
Humphrey, D. R., & Schmidt, E. M. (2003) · Neurophysiological Techniques, II · doi:10.1385/0-89603-185-3:1 · Cited by 99
Physiological Challenges for Intracortical Electrodes
Groothuis, J., Ramsey, N. F., Ramakers, G. M. J., & Plasse, G. (2013) · Brain stimulation · doi:10.1016/j.brs.2013.07.001 · Cited by 86
Zhao, Q., Casas‐Bejar, J., Urbanski, P., & Stokes, K. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820290406 · Cited by 77
The influence of thermal history on structure and water transport in Parylene C coatings
Davis, E. M., Benetatos, N. M., Regnault, W. F., Winey, K. I., & Elabd, Y. A. (2011) · Polymer · doi:10.1016/j.polymer.2011.08.010 · Cited by 76
An ultra-compliant, scalable neural probe with molded biodissolvable delivery vehicle
Gilgunn, P. J., Khilwani, R., Kozai, T. D. Y., Weber, D. J., Cui, X. T., Erdos, G., Ozdoganlar, O. B., & Fedder, G. K. (2012) · 2012 IEEE 25th International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2012.6170092 · Cited by 65
Degradation of medical‐grade polyurethane elastomers: The effect of hydrogen peroxide in vitro
Meijs, G. F., McCarthy, S. J., Rizzardo, E., Chen, Y., Chatelier, R. C., Brandwood, A., & Schindhelm, K. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270308 · Cited by 62
Malaga, K. A., Schroeder, K. E., Patel, P. R., Irwin, Z. T., Thompson, D. E., Nicole Bentley, J., Lempka, S. F., Chestek, C. A., & Patil, P. G. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/1/016010 · Cited by 55
Structural modifications in chronic microwire electrodes for cortical neuroprosthetics: a case study
Sanchez, J. C., Alba, N., Nishida, T., Batich, C., & Carney, P. R. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875581 · Cited by 45
Neural Interfaces for Upper-Limb Prosthesis Control: Opportunities to Improve Long-Term Reliability
Judy, J. W. (2012) · IEEE Pulse · doi:10.1109/mpul.2011.2181026 · Cited by 29
Chichili, G. R., Nöhr, D., Frank, J., Flaccus, A., Fraser, P. D., Enfissi, E. M. A., & Biesalski, H. K. (2006) · PubMed · Cited by 27
ChemInform Abstract: Color Images for Fast‐Scan CV Measurements in Biological Systems
MICHAEL, D., Travis, E. R., & Wightman, R. M. (1998) · ChemInform · doi:10.1002/chin.199848350 · Cited by 24
Ludwig, K. A., Miriani, R. M., Langhals, N. B., Marzullo, T., & Kipke, D. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/049801 · Cited by 21
McGie, S. C., Nagai, M. K., & Artinian-Shaheen, T. (2013) · IEEE Pulse · doi:10.1109/mpul.2013.2242014 · Cited by 13
FDA Regulation of Invasive Neural Recording Electrodes: A Daunting Task for Medical Innovators
Welle, C. G., & Krauthamer, V. (2012) · IEEE Pulse · doi:10.1109/mpul.2011.2181022 · Cited by 11
Self-citationMcGie, S. C., Nagai, M. K., & Artinian-Shaheen, T. (2013) · IEEE Pulse · doi:10.1109/mpul.2012.2228810 · Cited by 7
Is the Extent of Blood-Brain-Barrier Breach Predictive of Intracortical Electrode Performance?
Bellamkonda, R. V., Karumbaiah, L., Saxena, T. K., Wang, Q., & Stanley, G. B. (2013) · Biophysical Journal · doi:10.1016/j.bpj.2012.11.2092 · Cited by 6
Cited by
Biodegradable Materials and Metallic Implants—A Review
Prakasam, M., Locs, J., Salma-Ancane, K., Loca, D., Largeteau, A., & Berzina-Cimdina, L. (2017) · Journal of Functional Biomaterials · doi:10.3390/jfb8040044 · Cited by 493
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Boehler, C., Carli, S., Fadiga, L., Stieglitz, T., & Asplund, M. (2020) · Nature Protocols · doi:10.1038/s41596-020-0389-2 · Cited by 308
A review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133
Conformable hybrid systems for implantable bioelectronic interfaces
Fallegger, F., Schiavone, G., & Lacour, S. P. (2020) · Advanced Materials · doi:10.1002/adma.201903904 · Cited by 113
Metadata
- Authors
- Takmakov, P., Ruda, K., Scott Phillips, K., Isayeva, I. S., Krauthamer, V., & Welle, C. G.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2015-01-28
- Volume
- 12
- Issue
- 2
- Pages
- 026003
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2095586334
- Cited by
- 178
- References
- 71
- FWCI
- 6.46
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.