The DOI matches its Crossref record; 33 of the 34 references it cites were found in a registry or an index.
Electric crosstalk impairs spatial resolution of multi-electrode arrays in retinal implants
Open accessAbstract
Active multi-electrode arrays are used in vision prostheses, including optic nerve cuffs and cortical and retinal implants for stimulation of neural tissue. For retinal implants, arrays with up to 1500 electrodes are used in clinical trials. The ability to convey information with high spatial resolution is critical for these applications. To assess the extent to which spatial resolution is impaired by electric crosstalk, finite-element simulation of electric field distribution in a simplified passive tissue model of the retina is performed. The effects of electrode size, electrode spacing, distance to target cells, and electrode return configuration (monopolar, tripolar, hexagonal) on spatial resolution is investigated in the form of a mathematical model of electric field distribution. Results show that spatial resolution is impaired with increased distance from the electrode array to the target cells. This effect can be partly compensated by non-monopolar electrode configurations and larger electrode diameters, albeit at the expense of lower pixel densities due to larger covering areas by each stimulation electrode. In applications where multi-electrode arrays can be brought into close proximity to target cells, as presumably with epiretinal implants, smaller electrodes in monopolar configuration can provide the highest spatial resolution. However, if the implantation site is further from the target cells, as is the case in suprachoroidal approaches, hexagonally guarded electrode return configurations can convey higher spatial resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In contrast, current prosthesis users report seeing highly distorted phosphenes, which vary in shape across subjects as well as electrodes and often fail to assemble into more complex percepts (Wilke et al., 2011; Beyeler et al., 2019; Beauchamp et al., 2020; Erickson-Davis and Korzybska, 2021; Fernández et al., 2021).”
From Towards a Smart Bionic Eye : AI-powered artificial vision for the treatment of incurable blindness (2022) · cites this paper as Wilke et al., 2011
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gabriel, S., Lau, R.-W.-M., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/002 · Cited by 4,487
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Subretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819
Self-citationWill Retinal Implants Restore Vision?
Zrenner, E. (2002) · Science · doi:10.1126/science.1067996 · Cited by 736
Retinal remodeling during retinal degeneration
Jones, B. W., & Marc, R. E. (2005) · Experimental Eye Research · doi:10.1016/j.exer.2005.03.006 · Cited by 430
Electrical Stimulation of Mammalian Retinal Ganglion Cells With Multielectrode Arrays
Sekirnjak, C., Hottowy, P., Sher, A., Dąbrowski, W., Litke, A. M., & Chichilnisky, E. J. (2006) · Journal of Neurophysiology · doi:10.1152/jn.01168.2005 · Cited by 342
Design of a high-resolution optoelectronic retinal prosthesis
Palanker, D., Vankov, A., Huie, P., & Baccus, S. A. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/1/012 · Cited by 330
Non-linear projection of the retinal image in a wide-angle schematic eye.
Drasdo, N., & Fowler, C. W. (1974) · British Journal of Ophthalmology · doi:10.1136/bjo.58.8.709 · Cited by 312
Axonal Sodium-Channel Bands Shape the Response to Electric Stimulation in Retinal Ganglion Cells
Fried, S. I., Lasker, A., Desai, N. J., Eddington, D. K., & Rizzo, J. F. (2009) · Journal of Neurophysiology · doi:10.1152/jn.91081.2008 · Cited by 206
Current focusing and steering: Modeling, physiology, and psychophysics
Bonham, B. H., & Litvak, L. M. (2008) · Hearing Research · doi:10.1016/j.heares.2008.03.006 · Cited by 198
Research works printed but not linked: 7
- Benav H Wilke R Stett A Zrenner E, 2009, ARVO Meeting Abstracts, 50, 4593
- Dommel N, 2005, Conf. Proc. IEEE Eng. Med. Biol. Soc., 7, 7612
- Lovell N H, 2005, Conf. Proc. IEEE Eng. Med. Biol. Soc., 5, 5242
- Schmid E W, 2008, U S Patent Specification 7840273
- Wilke R, 2011, Invest. Ophthalmol. Vis. Sci.
- Wilke R Greppmaier U Harscher A Benav H Zrenner E, 2010, ARVO Meeting Abstracts, 51, 2026
- Wilke R G, 2011, ARVO Meeting Abstracts, 52, 458
Cited by
Sorted by citations
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Retinal stimulation strategies to restore vision: fundamentals and systems
Yue, L., Weiland, J. D., Roska, B., & Humayun, M. S. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2016.05.002 · Cited by 272
A model of ganglion axon pathways accounts for percepts elicited by retinal implants
Beyeler, M., Nanduri, D., Weiland, J. D., Rokem, A., Boynton, G. M., & Fine, I. (2019) · Scientific Reports · doi:10.1038/s41598-019-45416-4 · Cited by 143
Wilke, R., Gabel, V.-P., Sachs, H., Bartz Schmidt, K.-U., Gekeler, F., Besch, D., Szurman, P., Stett, A., Wilhelm, B., Peters, T., et al. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6946 · Cited by 155
Self-citationGold nanostructures: synthesis, properties, and neurological applications
Zare, I., Yaraki, M. T., Speranza, G., Najafabadi, A. H., Shourangiz-Haghighi, A., Nik, A. B., Manshian, B. B., Saraiva, C., Soenen, S. J., Kogan, M. J., et al. (2022) · Chemical Society Reviews · doi:10.1039/d1cs01111a · Cited by 133
Mandel, Y., Goetz, G. A., Lavinsky, D., Huie, P., Mathieson, K., Wang, L., Kamins, T. I., Galambos, L., Manivanh, R. V., Harris, J. S., et al. (2013) · Nature Communications · doi:10.1038/ncomms2980 · Cited by 131
Zeng, Q., & Huang, Z. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202301223 · Cited by 104
Goding, J. A., Gilmour, A. D., Robles, U. A. A., Hasan, E. A., & Green, R. A. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201702969 · Cited by 94
Neural interfaces: Bridging the brain to the world beyond healthcare
Xu, S., Liu, Y., Lee, H., & Li, W. (2024) · Exploration · doi:10.1002/exp.20230146 · Cited by 102
Cicione, R., Shivdasani, M. N., Fallon, J. B., Luu, C. D., Allen, P. J., Rathbone, G. D., Shepherd, R. K., & Williams, C. E. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/3/036009 · Cited by 79
Current steering in retinal stimulation via a quasimonopolar stimulation paradigm
Matteucci, P. B., Chen, S. C., Tsai, D., Dodds, C. W. D., Dokos, S., Morley, J. W., Lovell, N. H., & Suaning, G. J. (2013) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.13-11653 · Cited by 79
Self-citationAttaining higher resolution visual prosthetics: a review of the factors and limitations
Eiber, C. D., Lovell, N. H., & Suaning, G. J. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/1/011002 · Cited by 71
Self-citationDagnelie, G. (2011) · Current Opinion in Neurology · doi:10.1097/wco.0b013e32834f02c3 · Cited by 71
Honeycomb-shaped electro-neural interface enables cellular-scale pixels in subretinal prosthesis
Flores, T. A., Huang, T., Bhuckory, M. B., Ho, E., Chen, Z., Dalal, R., Galambos, L., Kamins, T. I., Mathieson, K., & Palanker, D. (2019) · Scientific Reports · doi:10.1038/s41598-019-47082-y · Cited by 61
Optimization of pillar electrodes in subretinal prosthesis for enhanced proximity to target neurons
Flores, T., Lei, X., Huang, T., Lorach, H., Dalal, R., Galambos, L., Kamins, T., Mathieson, K., & Palanker, D. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaac39 · Cited by 57
Towards high-resolution retinal prostheses with direct optical addressing and inductive telemetry
Ha, S., Khraiche, M. L., Akinin, A., Jing, Y., Damle, S., Kuang, Y. J., Bauchner, S., Lo, Y., Freeman, W. R., Silva, G. A., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/5/056008 · Cited by 52
de Ruyter van Steveninck, J., van Gestel, T., Koenders, P., van der Ham, G., Vereecken, F., Güçlü, U., van Gerven, M., Güçlütürk, Y., & van Wezel, R. (2022) · Journal of Vision · doi:10.1167/jov.22.2.1 · Cited by 51
Deep Learning–Based Scene Simplification for Bionic Vision
Han, N., Srivastava, S., Xu, A., Klein, D., & Beyeler, M. (2021) · Augmented Humans Conference 2021 · doi:10.1145/3458709.3458982 · Cited by 45
Optimization of return electrodes in neurostimulating arrays
Flores, T., Goetz, G., Lei, X., & Palanker, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036010 · Cited by 43
Shivdasani, M. N., Fallon, J. B., Luu, C. D., Cicione, R., Allen, P. J., Morley, J. W., & Williams, C. E. (2012) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.12-9434 · Cited by 42
High-amplitude electrical stimulation can reduce elicited neuronal activity in visual prosthesis
Barriga‐Rivera, A., Guo, T., Yang, C.-Y., Abed, A. A., Dokos, S., Lovell, N. H., Morley, J. W., & Suaning, G. J. (2017) · Scientific Reports · doi:10.1038/srep42682 · Cited by 40
Self-citation1225-Channel Neuromorphic Retinal-Prosthesis SoC With Localized Temperature-Regulation
Park, J. H., Tan, J. S. Y., Wu, H., Dong, Y., & Yoo, J. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.3036091 · Cited by 39
The Effect of Electric Cross-Talk in Retinal Neurostimulation
Matteucci, P. B., Barriga‐Rivera, A., Eiber, C. D., Lovell, N. H., Morley, J. W., & Suaning, G. J. (2016) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.15-18400 · Cited by 40
Self-citationImproved visual acuity using a retinal implant and an optimized stimulation strategy
Tong, W., Stamp, M. E. M., Apollo, N. V., Ganesan, K., Hamish Meffin, A., Prawer, S., Garrett, D. J., & Ibbotson, M. R. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab5299 · Cited by 39
Quasi-monopolar electrical stimulation of the retina: a computational modelling study
Abramian, M., Lovell, N. H., Habib, A., Morley, J. W., Suaning, G. J., & Dokos, S. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/025002 · Cited by 35
Self-citationTowards a Smart Bionic Eye : AI-powered artificial vision for the treatment of incurable blindness
Beyeler, M., & Sanchez-Garcia, M. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/aca69d · Cited by 35
“…prosthesis users report seeing highly distorted phosphenes, which vary in shape across subjects as well as electrodes and often fail to assemble into more complex percepts (Wilke et al., 2011; Beyeler et al., 2019; Beauchamp et al., 2020; Erickson-Davis and Korzybska, 2021; Fernández et al., 2021).”
BackgroundProgress in artificial vision through suprachoroidal retinal implants
Bareket, L., Barriga‐Rivera, A., Zapf, M. P., Lovell, N. H., & Suaning, G. J. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa6cbb · Cited by 36
Self-citationModel-based analysis of multiple electrode array stimulation for epiretinal visual prostheses
Mueller, J. K., & Grill, W. M. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036002 · Cited by 32
Spencer, T. C., Fallon, J. B., Thien, P. C., & Shivdasani, M. N. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-19325 · Cited by 31
Creating virtual electrodes with 2D current steering
Spencer, T. C., Fallon, J. B., & Shivdasani, M. N. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab1b8 · Cited by 31
Correlated Activity in the Degenerate Retina Inhibits Focal Response to Electrical Stimulation
Ahn, J., Cha, S., Choi, K.-E., Kim, S., Yoo, Y., & Goo, Y. S. (2022) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2022.889663 · Cited by 29
Global activity shaping strategies for a retinal implant
Spencer, M. J., Kameneva, T., Grayden, D. B., Meffin, H., & Burkitt, A. N. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaf071 · Cited by 28
Impedance measures for a better understanding of the electrical stimulation of the inner ear
Mesnildrey, Q., Macherey, O., Herzog, P., & Venail, F. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaecff · Cited by 25
Optopharmacological tools for restoring visual function in degenerative retinal diseases
Tochitsky, I., & Krämer, R. (2015) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2015.01.018 · Cited by 26
Fractal Electrodes as a Generic Interface for Stimulating Neurons
Watterson, W. J., Montgomery, R. D., & Taylor, R. P. (2017) · Scientific Reports · doi:10.1038/s41598-017-06762-3 · Cited by 29
Neural Responses to Multielectrode Stimulation of Healthy and Degenerate Retina
Halupka, K. J., Abbott, C. J., Wong, Y. T., Cloherty, S. L., Grayden, D. B., Burkitt, A. N., Sergeev, E. N., Luu, C. D., Brandli, A. A., Allen, P. J., et al. (2017) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.16-21290 · Cited by 24
Paknahad, J., Loizos, K., Humayun, M. S., & Lazzi, G. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.3027560 · Cited by 24
Performance optimization of current focusing and virtual electrode strategies in retinal implants
Moghaddam, G. K., Lovell, N. H., Wilke, R. G. H., Suaning, G. J., & Dokos, S. (2014) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2014.06.012 · Cited by 24
Self-citationWu, C., Tseng, C.-K., Liao, J.-H., Chiao, C., Chu, F.-L., Tsai, Y.-C., Ohta, J., & Noda, T. (2020) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2020.2976716 · Cited by 23
A 3D flexible microelectrode array for subretinal stimulation
Seo, H. W., Kim, N., Ahn, J., Cha, S., Goo, Y. S., & Kim, S. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab36ab · Cited by 22
Zhang, H., Vecchio, D. A., Emre, A. E., Rahmani, S., Cheng, C., Zhu, J. G., Misra, A. C., Lahann, J., & Kotov, N. A. (2021) · MRS Bulletin · doi:10.1557/s43577-021-00071-x · Cited by 22
Shimazaki, T., & Nakajima, T. (2016) · The Journal of Chemical Physics · doi:10.1063/1.4953905 · Cited by 19
Khalili Moghadam, G., Wilke, R., Suaning, G. J., Lovell, N. H., & Dokos, S. (2013) · PLoS ONE · doi:10.1371/journal.pone.0073130 · Cited by 18
Self-citationElectronic restoration of vision in those with photoreceptor degenerations
O'Brien, E. E., Greferath, U., Vessey, K. A., Jobling, A. I., & Fletcher, E. L. (2012) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2012.00783.x · Cited by 18
Shimazaki, T., & Nakajima, T. (2015) · Physical Chemistry Chemical Physics · doi:10.1039/c5cp00740b · Cited by 19
Cicione, R., Fallon, J. B., Rathbone, G. D., Williams, C. E., & Shivdasani, M. N. (2014) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.14-14754 · Cited by 17
Suppression of crosstalk in multielectrode arrays with local shielding
Naughton, J. R., Varela, J. A., Connolly, T., Shepard, S., Dodge, T., Kempa, K., Burns, M. J., Christianson, J. P., & Naughton, M. J. (2022) · Frontiers in Nanotechnology · doi:10.3389/fnano.2022.948337 · Cited by 17
Choi, D.-H., & Jee, D. (2023) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2023.3284460 · Cited by 17
Aligning Visual Prosthetic Development With Implantee Needs
Nadolskis, L., Turkstra, L. M., Larnyo, E., & Beyeler, M. (2024) · Translational Vision Science & Technology · doi:10.1167/tvst.13.11.28 · Cited by 16
Devices for the electrical stimulation of the olfactory system: A review
Lipp, C., Laamari, L., Bertsch, A., Podlesek, D., Bensafi, M., Hummel, T. R., & Brugger, J. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.117063 · Cited by 15
Spinal cord bioelectronic interfaces: opportunities in neural recording and clinical challenges
Jiang, L., Woodington, B. J., Carnicer‐Lombarte, A., Malliaras, G. G., & Barone, D. G. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac605f · Cited by 14
Biophysical basis of the linear electrical receptive fields of retinal ganglion cells
Esler, T. B., Maturana, M. I., Kerr, R. R., Grayden, D. B., Burkitt, A. N., & Hamish Meffin, A. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aacbaa · Cited by 15
Axonal stimulation affects the linear summation of single-point perception in three Argus II users
Hou, Y., Nanduri, D., Granley, J., Weiland, J. D., & Beyeler, M. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad31c4 · Cited by 14
Fabrication of Subretinal 3D Microelectrodes with Hexagonal Arrangement
Seo, H. W., Kim, N., & Kim, S. (2020) · Micromachines · doi:10.3390/mi11050467 · Cited by 14
A model of ganglion axon pathways accounts for percepts elicited by retinal implants
Beyeler, M., Nanduri, D., Weiland, J. D., Rokem, A., Boynton, G. M., & Fine, I. (2018) · doi:10.1101/453035 · Cited by 13
The impact of synchronous versus asynchronous electrical stimulation in artificial vision
Moleirinho, S., Whalen, A. J., Fried, S. I., & Pezaris, J. S. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abecf1 · Cited by 14
Virtual electrode design for increasing spatial resolution in retinal prosthesis
Loizos, K., Cela, C., Marc, R. E., & Lazzi, G. (2016) · Healthcare Technology Letters · doi:10.1049/htl.2015.0043 · Cited by 13
Minimizing iridium oxide electrodes for high visual acuity subretinal stimulation
Damle, S., Carleton, M., Kapogianis, T., Arya, S., Cavichini-Corderio, M., Freeman, W. R., Lo, Y.-H., & Oesch, N. W. (2021) · eNeuro · doi:10.1523/eneuro.0506-20.2021 · Cited by 11
“The limit of prosthetic spatial resolution is determined by the size and spacing of stimulating electrodes in implanted arrays (Palanker et al., 2005; Wilke et al., 2011).”
BackgroundMethodInfluentialInfrared neuromodulation—a review
Sander, M. Y., & Zhu, X. (2024) · Reports on Progress in Physics · doi:10.1088/1361-6633/ad4729 · Cited by 11
Barriga‐Rivera, A., Morley, J. W., Lovell, N. H., & Suaning, G. J. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591956 · Cited by 11
Self-citationSequential epiretinal stimulation improves discrimination in simple shape discrimination tasks only
Christie, B., Sadeghi, R., Kartha, A., Caspi, A., Tenore, F. V., Klatzky, R. L., Dagnelie, G., & Billings, S. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac7326 · Cited by 10
In vivo feasibility of epiretinal stimulation using ultrananocrystalline diamond electrodes
Shivdasani, M. N., Evans, M., Burns, O., Yeoh, J., Allen, P. J., Nayagam, D. A. X., Villalobos, J., Abbott, C. J., Luu, C. D., Opie, N. L., et al. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/aba560 · Cited by 10
Access resistance of stimulation electrodes as a function of electrode proximity to the retina
Majdi, J. A., Minnikanti, S., Peixoto, N., Agrawal, A., & Cohen, E. D. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016006 · Cited by 9
Degenerated Cones in Cultured Human Retinas Can Successfully Be Optogenetically Reactivated
Kamar, S., Howlett, M. H. C., Klooster, J., de Graaff, W., Csikós, T., Rabelink, M. J. W. E., Hoeben, R. C., & Kamermans, M. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21020522 · Cited by 9
Oh, Y., Hong, J., & Kim, J. (2024) · PLoS ONE · doi:10.1371/journal.pone.0305132 · Cited by 8
Greedy Optimization of Electrode Arrangement for Epiretinal Prostheses
Bruce, A., & Beyeler, M. (2022) · Lecture notes in computer science · doi:10.1007/978-3-031-16449-1_57 · Cited by 9
What limits spatial perception with retinal implants?
Hamish Meffin, A. (2013) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.2013.6738318 · Cited by 7
Kiral-Kornek, F. I., O’Sullivan-Greene, E., Savage, C. O., McCarthy, C. D., Grayden, D. B., & Burkitt, A. N. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/6/066002 · Cited by 6
Seo, H. W., Cha, S., Jeong, Y., Ahn, J., Lee, K. J., Kim, S., & Goo, Y. S. (2023) · Biomedical Engineering Letters · doi:10.1007/s13534-023-00342-3 · Cited by 6
Shimazaki, T., & Nakajima, T. (2017) · Physical Chemistry Chemical Physics · doi:10.1039/c7cp01455d · Cited by 6
Differences in the spatial fidelity of evoked and spontaneous signals in the degenerating retina
Carleton, M., & Oesch, N. W. (2022) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2022.1040090 · Cited by 5
Cojocaru, A.-E., Corna, A., Reh, M., & Zeck, G. M. (2022) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2022.1033738 · Cited by 5
Wu, C., Liu, H.-H., Chen, P.-H., Chiao, C., Chu, F.-L., Tsai, Y.-C., Chen, P., Tsai, W.-Y., Wu, Y.-H., & Tseng, C.-K. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3098734 · Cited by 5
Neural Activity Shaping in Visual Prostheses with Deep Learning
Castro, D., Grayden, D. B., Meffin, H., & Spencer, M. (2023) · doi:10.1101/2023.12.20.572123 · Cited by 4
Deep Learning--Based Scene Simplification for Bionic Vision
Han, N., Srivastava, S., Xu, A., Klein, D., & Beyeler, M. (2021) · arXiv · doi:10.48550/arxiv.2102.00297 · Cited by 4
Parasitic Capacitance in High-Density Neural Electrode Arrays: Sources and Evaluation Methods
Ghazavi, A., Troyk, P. R., & Cogan, S. F. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3472708 · Cited by 4
Neural activity shaping in visual prostheses with deep learning
Castro, D., Grayden, D. B., Hamish Meffin, A., & Spencer, M. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad6186 · Cited by 6
Optimized single pulse stimulation strategy for retinal implants
Savage, C. O., Grayden, D. B., Hamish Meffin, A., & Burkitt, A. N. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/1/016003 · Cited by 5
Quantifying visual acuity for pre-clinical testing of visual prostheses
Spencer, M., Kameneva, T., Grayden, D. B., Burkitt, A. N., & Hamish Meffin, A. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac9c95 · Cited by 4
Peiroten, L., Zrenner, E., & Haq, W. (2023) · Bioengineering · doi:10.3390/bioengineering10101208 · Cited by 4
Spencer, M., Hosie, S., Tong, W., Shivdasani, M. N., Garrett, D. J., León, S. E. D., Brunton, E., Kameneva, T., Grayden, D. B., Fallon, J. B., et al. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/adfc9b · Cited by 3
Kasowski, J., Varshney, A., Sadeghi, R., & Beyeler, M. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/adecc4 · Cited by 5
Li, W. (2012) · Elsevier eBooks · doi:10.1533/9780857096272.4.396 · Cited by 3
Wu, J., Yin, S., Zhou, Y., Li, J., Li, K., Shen, X., Sun, T., Zhang, X., & Wang, K. (2025) · Custom Integrated Circuits Conference · doi:10.1109/cicc63670.2025.10982821 · Cited by 3
Restoration of the senses and human communication: Sustainable Development Goals 3 and 9
Zoneff, E. R., Gao, D. X., Nisbet, D. R., Grayden, D. B., & Clark, G. M. (2022) · International Journal of Speech-Language Pathology · doi:10.1080/17549507.2022.2142290 · Cited by 3
Shalbaf, F., Dokos, S., Lovell, N. H., Turuwhenua, J., & Vaghefi, E. (2014) · Journal of Modern Optics · doi:10.1080/09500340.2014.988766 · Cited by 3
Self-citationCan electric current steering be used to control perception of a retinal prosthesis patient
Savage, C. O., Kiral-Kornek, F. I., Tahayori, B., & Grayden, D. B. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346598 · Cited by 3
Tsai, Y.-C., Wu, J. J.-S., Lin, P.-K., Lin, B.-J., Wang, P.-S., Liu, C.-H., Wu, C.-Y., & Chiao, C. (2020) · PLoS ONE · doi:10.1371/journal.pone.0228861 · Cited by 3
Neural activity shaping utilizing a partitioned target pattern
Spencer, M., Kameneva, T., Grayden, D. B., Burkitt, A. N., & Hamish Meffin, A. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abecc4 · Cited by 4
Yoon, Y. H., Yue, L., & Humayun, M. S. (2020) · Springer eBooks · doi:10.1007/978-981-15-7644-7_34 · Cited by 2
Computational Modeling of Retinal Neurons for Visual Prosthesis Research - Fundamental Approaches
Pratiwi, A. M., Kékesi, O., & Suaning, G. J. (2022) · Journal of Visualized Experiments · doi:10.3791/63792 · Cited by 2
Self-citationAsghar, S. A., & Mahadevappa, M. (2023) · IEEE Transactions on NanoBioscience · doi:10.1109/tnb.2023.3319084 · Cited by 3
Resources, V. (2012) · Cited by 2
Retinal Prostheses: Bioengineering Considerations
Chang, Y.-C., Weiland, J. D., & Humayun, M. S. (2017) · Essentials in ophthalmology/Essentials ophthalmology · doi:10.1007/978-3-319-67260-1_2 · Cited by 2
Farah, N., Markus, A., Shpun, G., Chemla, Y., Lasnoy, E., Leibovitch, T. A., Fentahon, F., Zalvesky, Z., & Mandel, Y. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202512621 · Cited by 1
Fuzzing the brain: automated stress testing for the safety of ML-driven neurostimulation
Downing, M., Peng, M., Granley, J., Beyeler, M., & Bultan, T. (2026) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae4927 · Cited by 2
Feature accentuation in phosphenated images
Kiral-Kornek, F. I., Savage, C. O., Grayden, D. B., & Burkitt, A. N. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6347340 · Cited by 1
Kim, H.-B., Oh, T. I., Swanberg, K. M., Lee, M.-B., Kim, T., Woo, E., Park, J. H., & Kwon, O. I. (2016) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2016.02.011 · Cited by 1
Photovoltaic retinal prosthesis for restoring sight to the blind
Palanker, D., Mandel, Y., Mathieson, K., Loudin, J., Goetz, G. A., Huie, P., Wang, L., Kamins, T. I., Smith, R., Harris, J. S., et al. (2015) · Cambridge University Press eBooks · doi:10.1017/cbo9781139629539.031 · Cited by 1
Çelik, M. E., & Karagöz, İ. (2017) · Gazi Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi · doi:10.17341/gazimmfd.322183 · Cited by 1
Metadata
- Authors
- Wilke, R. G. H., Moghadam, G. K., Lovell, N. H., Suaning, G. J., & Dokos, S.
- Affiliations
- UNSW Sydney (AU)
- Corresponding author
- Lovell, N H
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2011-06-15
- Volume
- 8
- Issue
- 4
- Pages
- 046016
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2084193319
- Cited by
- 110
- References
- 34
- Citations by year
- 2026: 3 · 2025: 9 · 2024: 8 · 2023: 5 · 2022: 15 · 2021: 8 · 2020: 8 · 2019: 4 · 2018: 6 · 2017: 10 · 2016: 9 · 2015: 3 · 2014: 6 · 2013: 6 · 2012: 8
- FWCI
- 2.92
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Deutsche Forschungsgemeinschaft
- University of New South Wales
- Eberhard Karls Universität Tübingen
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › CCD and CMOS Imaging Sensors
- Keywords
- retinal prosthesis, microelectrode arrays, spatial resolution, electric field distribution, electrode configuration, monopolar electrodes, electrode diameter, electrode spacing, epiretinal implants, finite element analysis
- MeSH terms
- Algorithms, Electrodes, Implanted, Electromagnetic Fields, Electronics, Prosthesis Design, Retina, Models, Statistical, Prostheses and Implants, Finite Element Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review