Spatial and temporal characteristics of V1 microstimulation during chronic implantation of a microelectrode array in a behaving macaque
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: It has been hypothesized that a vision prosthesis capable of evoking useful visual percepts can be based upon electrically stimulating the primary visual cortex (V1) of a blind human subject via penetrating microelectrode arrays. As a continuation of earlier work, we examined several spatial and temporal characteristics of V1 microstimulation. APPROACH: An array of 100 penetrating microelectrodes was chronically implanted in V1 of a behaving macaque monkey. Microstimulation thresholds were measured using a two-alternative forced choice detection task. Relative locations of electrically-evoked percepts were measured using a memory saccade-to-target task. MAIN RESULTS: The principal finding was that two years after implantation we were able to evoke behavioural responses to electric stimulation across the spatial extent of the array using groups of contiguous electrodes. Consistent responses to stimulation were evoked at an average threshold current per electrode of 204 ± 49 µA (mean ± std) for groups of four electrodes and 91 ± 25 µA for groups of nine electrodes. Saccades to electrically-evoked percepts using groups of nine electrodes showed that the animal could discriminate spatially distinct percepts with groups having an average separation of 1.6 ± 0.3 mm (mean ± std) in cortex and 1.0° ± 0.2° in visual space. Significance. These results demonstrate chronic perceptual functionality and provide evidence for the feasibility of a cortically-based vision prosthesis for the blind using penetrating microelectrodes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243 · cited 1×
“Each electrode tip is metalized with a sputtered iridium-oxide film (SIROF) for better charge injection capacity [39].”
Cortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170
Campbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881 · cited 1×
“These arrays were originally developed for a vision prosthesis [14, 15].”
BackgroundSelf-citationSchmidt, E. M., Bak, M. J., Hambrecht, F. T., Kufta, C. V., O'Rourke, D. K., & Vallabhanath, P. (1996) · Brain · doi:10.1093/brain/119.2.507 · Cited by 672
Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646 · cited 1×
“They have been successfully implanted in the motor cortex [16–19], the auditory cortex [20, 21], the auditory nerve [22, 23], the sciatic nerve [24], and the visual cortex [25, 26] of various animal models.”
Self-citationDobelle, W. H., & Mladejovsky, M. G. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010766 · Cited by 468
In vitro electrical properties for iridium oxide versus titanium nitride stimulating electrodes
Weiland, J. D., Anderson, D. J., & Humayun, M. S. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.805487 · Cited by 382
Strength-duration properties of human peripheral nerve
Mogyoros, I., Kiernan, M. C., & Burke, D. (1996) · Brain · doi:10.1093/brain/119.2.439 · Cited by 358 · cited 1×
“This equation was found to provide the best fit for strength-duration data [41].”
MethodVisual sensations produced by intracortical microstimulation of the human occipital cortex
Bak, M., Girvin, J. P., Hambrecht, F. T., Kufta, C. V., Loeb, G. E., & Schmidt, E. M. (1990) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442682 · Cited by 299 · cited 1×
“Many V1 microstimulation studies have not reported an increase, but these studies were performed with either acute electrode placement or with chronic implantation of no more than 4 months [6, 9, 10, 46, 47].”
BackgroundOver-pulsing degrades activated iridium oxide films used for intracortical neural stimulation
Cogan, S. F., Guzelian, A. A., Agnew, W. F., Yuen, T. G. H., & McCreery, D. B. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.02.019 · Cited by 210 · cited 2×
“2 ms or less were determined to be safe to tissue and electrode according to a study by Cogan et al [44].”
BackgroundMethodRousche, P. J., & Normann, R. A. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.750552 · Cited by 187 · cited 1×
“time periods has been reported elsewhere [5, 6, 11].”
Self-citationBehavioral detection of electrical microstimulation in different cortical visual areas
Murphey, D. K., & Maunsell, J. H. R. (2007) · Current Biology · doi:10.1016/j.cub.2007.03.066 · Cited by 111
Torab, K., Davis, T. S., Warren, D. J., House, P. A., Normann, R. A., & Greger, B. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/035001 · Cited by 90
Self-citationPhosphene induction and the generation of saccadic eye movements by striate cortex
Tehovnik, E. J., Slocum, W. M., Carvey, C. E., & Schiller, P. H. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00736.2004 · Cited by 87
Warren, D. J., Fernandez, E., & Normann, R. A. (2001) · Neuroscience · doi:10.1016/s0306-4522(01)00174-9 · Cited by 77
Self-citationSelective motor unit recruitment via intrafascicular multielectrode stimulation
McDonnall, D., Clark, G. A., & Normann, R. A. (2004) · Canadian Journal of Physiology and Pharmacology · doi:10.1139/y04-047 · Cited by 53
Self-citation
Research works printed but not linked: 37
- 10.1016/S0002-9394(02)02110-4 · DOI · Paper page
- Pollen D A, 1975, Nerv. Syst., 2, 519
- 10.1152/jn.01213.2003 · DOI · Paper page
- 10.1152/jn.00406.2005 · DOI · Paper page
- 10.1152/jn.00407.2005 · DOI · Paper page
- 10.1111/j.1460-9568.2009.06695.x · DOI · Paper page
- Rousche P J, 1999, IEEE Trans. Biomed. Eng., 7, 56
- 10.1007/BF02368133 · DOI · Paper page
- Kaas J, 2004, The Primate Visual System, 265
- 10.1016/S0042-6989(99)00040-1 · DOI · Paper page
- Baker J Bishop W Kellis S Levy T House P Greger B, 2009, Annu. Int. Conf. IEEE Proc. Engineering in Medicine and Biology Society, 4573
- Hatsopoulos N Mukand J Polykoff G Friehs G Donoghue J, 2005, 27th Annu. Int. Conf. IEEE Proc. Engineering in Medicine and Biology Society, 7660
- Linderman M D Gilja V Santhanam G Afshar A Ryu S Meng T H Shenoy K V, 2006, Conf. Proc. IEEE Engineering in Medicine and Biology Society, 4387
- 10.1007/s10439-005-9037-9 · DOI
- 10.1097/00129492-200309000-00013 · DOI · Paper page
- 10.1097/MLG.0b013e31804714a7 · DOI
- 10.1016/S0165-0270(00)00159-X · DOI
- 10.3171/foc.2006.20.5.5 · DOI · Paper page
- 10.1093/brain/awq112 · DOI · Paper page
- 10.1097/WNP.0b013e3181fdf8a1 · DOI · Paper page
- 10.1097/WNP.0b013e31818e8010 · DOI · Paper page
- 10.1093/brain/awp222 · DOI · Paper page
- 10.1227/01.NEU.0000337575.63861.10 · DOI · Paper page
- Kim S P, 2008, J. Neural Eng., 5, 455, 10.1088/1741-2560/5/4/010 · DOI · Paper page
- 10.1097/01.wnp.0000233323.87127.14 · DOI
- 10.1523/JNEUROSCI.4415-07.2008 · DOI · Paper page
- 10.1523/JNEUROSCI.5443-09.2010 · DOI · Paper page
- 10.1152/jn.00512.2009 · DOI · Paper page
- 10.1016/j.jneumeth.2009.04.012 · DOI
- 10.1016/0014-4886(83)90270-4 · DOI
- 10.1111/j.1460-9568.2004.03480.x · DOI · Paper page
- 10.1016/B978-0-444-53815-4.00010-8 · DOI · Paper page
- 10.1007/s10439-010-9911-y · DOI
- 10.1016/j.neulet.2006.07.018 · DOI
- McCreery D, 2010, J. Neural. Eng., 7, 10.1088/1741-2560/7/3/036005 · DOI · Paper page
- Kane S R Cogan S F Ehrlich J Plante T D McCreery D B, 2011, Annu. Int. Conf. IEEE Proc. Engineering and Medicine Biology Society, 5416
- Negi S, 2010, Biomed. Mater., 5, 15007, 10.1088/1748-6041/5/1/015007 · DOI · Paper page
Cited by
Intracortical microstimulation of human somatosensory cortex
Flesher, S. N., Collinger, J. L., Foldes, S. T., Weiss, J. M., Downey, J. E., Tyler-Kabara, E. C., Bensmaia, S. J., Schwartz, A. B., Boninger, M. L., & Gaunt, R. A. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf8083 · Cited by 704
Davis, T. S., Wark, H. A. C., Hutchinson, D. T., Warren, D. J., O’Neill, K., Scheinblum, T., Clark, G. A., Normann, R. A., & Greger, B. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036001 · Cited by 314
Self-citationDynamic Stimulation of Visual Cortex Produces Form Vision in Sighted and Blind Humans
Beauchamp, M. S., Oswalt, D., Sun, P., Foster, B. L., Magnotti, J. F., Niketeghad, S., Pouratian, N., Bosking, W. H., & Yoshor, D. (2020) · Cell · doi:10.1016/j.cell.2020.04.033 · Cited by 257
“Conclusions Our work represents the continuation of decades of stimulating human and non-human primate visual cortex toward the goal of building a cortical visual prosthetic (Bak et al., 1990; Brindley and Lewin, 1968; Davis et al., 2012; DeYoe et al., 1989; Normann et al., 2009; Schiller and Tehovnik, 2008; Schmidt e…”
BackgroundShape perception via a high-channel-count neuroprosthesis in monkey visual cortex
Chen, X., Wang, F., Fernandez, E., & Roelfsema, P. R. (2020) · Science · doi:10.1126/science.abd7435 · Cited by 250
Lewis, P. M., Ackland, H. M., Lowery, A. J., & Rosenfeld, J. V. (2015) · Brain Research · doi:10.1016/j.brainres.2014.11.020 · Cited by 228
Metadata
- Authors
- Davis, T. S., Parker, R. A., House, P. A., Bagley, E., Wendelken, S., Normann, R. A., & Greger, B.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2012-11-27
- Volume
- 9
- Issue
- 6
- Pages
- 065003
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2012941001
- Cited by
- 91
- References
- 18
- FWCI
- 2.04
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.