In vitro comparison of sputtered iridium oxide and platinum-coated neural implantable microelectrode arrays
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
Neural interfaces connect signal processing electronics to the nervous system via implanted microelectrode arrays such as the Utah electrode array (UEA). The active sites of the UEA are coated with thin films of either platinum (Pt) or iridium oxide (IrOx). Pt and IrOx have attracted attention as a stimulating or recording material due to their ability to transfer between ionic and electronic current and to resist corrosion. The physical, mechanical, chemical, electrical and optical properties of thin films depend on the method and deposition parameters used to deposit the films. In this work, surface morphology, impedance and charge capacity of Pt and sputtered iridium oxide film (SIROF) were investigated and compared with each other. UEAs with similar electrode area and shape were employed in this study. DC sputtering was used to deposit Pt films and pulsed-dc reactive sputtering was used to deposit SIROF. The electrodes coated with SIROF and Pt were characterized by scanning electron microscopy, cyclic voltammetry, electrochemical impedance spectroscopy and potential transient measurements to measure charge injection capacity (CIC). SIROF and Pt selectively deposited on the electrode tip had dendrite and granular microstructure, respectively. The CIC of unbiased SIROF and Pt was 2 and 0.3 mC cm(-2), respectively. The average impedance at 1 kHz, of SIROF and Pt electrodes, was 6 kOmega and 125 kOmega, respectively. Low impedance and high CIC make SIROF promising stimulation/recording material for neural prosthetic applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thornton, J. A. (1974) · Journal of Vacuum Science and Technology · doi:10.1116/1.1312732 · Cited by 2,421 · cited 1×
“Different deposition methods like dc reactive sputtering [5, 6] and dc reactive magnetron sputtering [7] and deposition parameters like substrate bias [8], apparatus geometry [9], gas flow [10] and pressure [11] yield different degrees of porosity, roughness [12] and thickness, which in turn affect thin film propertie…”
MethodNeural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243 · cited 2×
“20% iridium) no significant change was observed [15, 35].”
BackgroundMethodConducting polymers in biomedical engineering
Guimard, N. K., Gomez, N., & Schmidt, C. E. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.012 · Cited by 1,599
Conjugated Polymer Actuators for Biomedical Applications
Smela, E. (2003) · Advanced Materials · doi:10.1002/adma.200390113 · Cited by 1,177 · cited 1×
“physiologically active species to enhance the biocompatibility and the functionality of the electrodes [26, 27].”
BackgroundCampbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881
Conducting‐Polymer Nanotubes for Controlled Drug Release
Abidian, M. R., Kim, D. ‐., & Martin, D. C. (2006) · Advanced Materials · doi:10.1002/adma.200501726 · Cited by 869 · cited 3×
“These properties of PEDOT make it of intense interest in biomedical applications [29].”
BackgroundCharge density and charge per phase as cofactors in neural injury induced by electrical stimulation
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102812 · Cited by 708 · cited 1×
“The neural damage threshold is roughly 1 mC cm−2 [36].”
BackgroundMultifunctional Nanobiomaterials for Neural Interfaces
Abidian, M. R., & Martin, D. C. (2009) · Advanced Functional Materials · doi:10.1002/adfm.200801473 · Cited by 416 · cited 1×
“Abidian et al [37] deposited PEDOT nanotubes (NT) on planar neural electrodes and calculated the CSC and impedance to be ∼110 mC cm−2 and ∼10 k at 1 kHz, respectively.”
BackgroundAnodic Iridium Oxide Films: XPS‐Studies of Oxidation State Changes and
Kötz, R., Neff, H., & Stucki, S. (1984) · Journal of The Electrochemical Society · doi:10.1149/1.2115548 · Cited by 404
In vitro electrical properties for iridium oxide versus titanium nitride stimulating electrodes
Weiland, J. D., Anderson, D. J., & Humayun, M. S. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.805487 · Cited by 382 · cited 4×
“The CSC of any material can be increased by increasing the surface area and thicknesses of the films but does not guarantee increase in the CIC of that material [25].”
BackgroundInfluentialRose, T. L., & Robblee, L. S. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.61038 · Cited by 358
A glass/silicon composite intracortical electrode array
Jones, K. E., Campbell, P. K., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368134 · Cited by 354
Abidian, M. R., & Martin, D. C. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.11.022 · Cited by 338
Cui, X., Hetke, J. F., Wiler, J. A., Anderson, D. J., & Martin, D. C. (2001) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(01)00637-9 · Cited by 330 · cited 1×
“PEDOT can be electrochemically polymerized as a film or nanotubes [28, 29] on the active sites of the microelectrodes.”
BackgroundNeural prostheses : fundamental studies
Agnew, W. F., & McCreery, D. B. (1990) · Medical Entomology and Zoology · Cited by 316
A method for pneumatically inserting an array of penetrating electrodes into cortical tissue
Rousche, P. J., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368133 · Cited by 306 · cited 1×
“When the UEA is inserted into the neural tissue, the coatings should withstand higher velocity insertion forces [40].”
MethodAbidian, M. R., Ludwig, K. A., Marzullo, T. C., Martin, D. C., & Kipke, D. R. (2009) · Advanced Materials · doi:10.1002/adma.200900887 · Cited by 255
A multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats
Branner, A., & Normann, R. A. (2000) · Brain Research Bulletin · doi:10.1016/s0361-9230(99)00231-2 · Cited by 234 · cited 1×
“The UEA is in either constant electrode length or varying electrode length, called Utah slant electrode array (USEA) [3], or in convoluted configurations [4].”
BackgroundActivated Ir: An Electrode Suitable for Reversible Charge Injection in Saline Solution
Robblee, L. S., Lefko, J. L., & Brummer, S. B. (1983) · Journal of The Electrochemical Society · doi:10.1149/1.2119793 · Cited by 227 · cited 1×
“Another material found to be useful is IrOx which has received considerable attention due to its ability to inject charge [13, 16, 17] and its resistance to corrosion [18].”
BackgroundBeebe, X., & Rose, T. L. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.2122 · Cited by 219
Sputtered iridium oxide films for neural stimulation electrodes
Cogan, S. F., Ehrlich, J., Plante, T. D., Smirnov, A., Shire, D. B., Gingerich, M., & Rizzo, J. F. (2009) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31223 · Cited by 188 · cited 1×
“SIROF CIC can further be increased to 9 mC cm−2 (with 1 ms pulse width) by biasing the electrodes, which is almost thrice that of PEDOT [6, 39].”
BackgroundTechnology Insight: future neuroprosthetic therapies for disorders of the nervous system
Normann, R. A. (2007) · Nature Clinical Practice Neurology · doi:10.1038/ncpneuro0556 · Cited by 167
Cogan, S. F., Troyk, P. R., Ehrlich, J., & Plante, T. D. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851503 · Cited by 162 · cited 6×
“values for unbiased SIROF electrodes [15].”
BackgroundInfluentialSputtered Iridium Oxide Films as Charge Injection Material for Functional Electrostimulation
Slavcheva, E., Vitushinsky, R., Mokwa, W., & Schnakenberg, U. (2004) · Journal of The Electrochemical Society · doi:10.1149/1.1747881 · Cited by 154 · cited 4×
“Different deposition methods like dc reactive sputtering [5, 6] and dc reactive magnetron sputtering [7] and deposition parameters like substrate bias [8], apparatus geometry [9], gas flow [10] and pressure [11] yield different degrees of porosity, roughness [12] and thickness, which in turn affect thin film propertie…”
BackgroundMethodInfluentialSputtered iridium oxide films (SIROFs) for low-impedance neural stimulation and recording electrodes
Cogan, S. F., Plante, T. D., & Ehrlich, J. (2005) · The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2004.1404158 · Cited by 138
Norlin, A., Pan, J., & Leygraf, C. (2002) · Biomolecular Engineering · doi:10.1016/s1389-0344(02)00013-8 · Cited by 125 · cited 1×
“At higher frequency (greater than 105 Hz), the impedance of Pt and SIROF converges which is attributed to the PBS solution impedance only [33].”
BackgroundIon conducting polymer microelectrodes for interfacing with neural networks.
Nyberg, T., Shimada, A., & Torimitsu, K. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.08.008 · Cited by 117
Oxidation State Changes and Structure of Electrochromic Iridium Oxide Films
McIntyre, J. D. E., Peck, W. F., & Nakahara, S. (1980) · Journal of The Electrochemical Society · doi:10.1149/1.2129868 · Cited by 103
Morphology and charge capacity of sputtered iridium oxide films
Klein, J. D., Clauson, S. L., & Cogan, S. F. (1989) · Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films · doi:10.1116/1.576313 · Cited by 62 · cited 2×
“Different deposition methods like dc reactive sputtering [5, 6] and dc reactive magnetron sputtering [7] and deposition parameters like substrate bias [8], apparatus geometry [9], gas flow [10] and pressure [11] yield different degrees of porosity, roughness [12] and thickness, which in turn affect thin film propertie…”
BackgroundMethodA novel method of fabricating convoluted shaped electrode arrays for neural and retinal prostheses
Bhandari, R., Negi, S., Rieth, L. W., Normann, R. A., & Solzbacher, F. (2007) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2007.10.072 · Cited by 59 · cited 1×
“The UEA is in either constant electrode length or varying electrode length, called Utah slant electrode array (USEA) [3], or in convoluted configurations [4].”
BackgroundSelf-citationBlue Sputtered Iridium Oxide Films (Blue SIROF's)
Kang, K. S., & Shay, J. L. (1983) · Journal of The Electrochemical Society · doi:10.1149/1.2119800 · Cited by 58
Effect of sputtering pressure on pulsed-DC sputtered iridium oxide films
Negi, S., Bhandari, R., Rieth, L. W., & Solzbacher, F. (2008) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2008.11.015 · Cited by 51 · cited 2×
“Different deposition methods like dc reactive sputtering [5, 6] and dc reactive magnetron sputtering [7] and deposition parameters like substrate bias [8], apparatus geometry [9], gas flow [10] and pressure [11] yield different degrees of porosity, roughness [12] and thickness, which in turn affect thin film propertie…”
MethodSelf-citationInfluence of deposition conditions on Ir/IrO2 oxygen barrier effectiveness
Pinnow, C. U., Kasko, I., Nagel, N., Poppa, S., Mikolajick, T., Dehm, C., Hösler, W., Bleyl, F., Jahnel, F., Seibt, M., et al. (2002) · Journal of Applied Physics · doi:10.1063/1.1471574 · Cited by 36 · cited 1×
“Different deposition methods like dc reactive sputtering [5, 6] and dc reactive magnetron sputtering [7] and deposition parameters like substrate bias [8], apparatus geometry [9], gas flow [10] and pressure [11] yield different degrees of porosity, roughness [12] and thickness, which in turn affect thin film propertie…”
MethodAn in vitro Analysis of Metal Electrodes for Use in the Neural Environment
Johnson, P. F., & Hench, L. L. (1977) · Brain, Behavior and Evolution · doi:10.1159/000124612 · Cited by 31 · cited 1×
“Another material found to be useful is IrOx which has received considerable attention due to its ability to inject charge [13, 16, 17] and its resistance to corrosion [18].”
BackgroundKlein, J. D., Clauson, S. L., & Cogan, S. F. (1989) · Journal of materials research/Pratt's guide to venture capital sources · doi:10.1557/jmr.1989.1505 · Cited by 28 · cited 1×
“Different deposition methods like dc reactive sputtering [5, 6] and dc reactive magnetron sputtering [7] and deposition parameters like substrate bias [8], apparatus geometry [9], gas flow [10] and pressure [11] yield different degrees of porosity, roughness [12] and thickness, which in turn affect thin film propertie…”
MethodPreparation and Characterization of Iridium Oxide Thin Films Grown by DC Reactive Sputtering
Cho, H., Horii, H., Hwang, C. S., Kim, J.-W., Kang, C. S., Lee, B. T., Lee, S. I., Koh, Y.-B., & Lee, M. Y. (1997) · Japanese Journal of Applied Physics · doi:10.1143/jjap.36.1722 · Cited by 28 · cited 1×
“Different deposition methods like dc reactive sputtering [5, 6] and dc reactive magnetron sputtering [7] and deposition parameters like substrate bias [8], apparatus geometry [9], gas flow [10] and pressure [11] yield different degrees of porosity, roughness [12] and thickness, which in turn affect thin film propertie…”
MethodInside Front Cover: Conducting‐Polymer Nanotubes for Controlled Drug Release (Adv. Mater. 4/2006)
Abidian, M. R., Kim, D., & Martin, D. C. (2006) · Advanced Materials · doi:10.1002/adma.200690018 · Cited by 15
Cited by
Intracortical microstimulation of human somatosensory cortex
Flesher, S. N., Collinger, J. L., Foldes, S. T., Weiss, J. M., Downey, J. E., Tyler-Kabara, E. C., Bensmaia, S. J., Schwartz, A. B., Boninger, M. L., & Gaunt, R. A. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf8083 · Cited by 704
Progress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384
“(45) Furthermore, conformal ParyleneC coatings have been applied through chemical vapor deposition to provide additional insulation to the electrode tines and protect the underlying dielectrics from dissolution.”
MethodIn Vitro and In Vivo Evaluation of PEDOT Microelectrodes for Neural Stimulation and Recording
Venkatraman, S., Hendricks, J., King, Z. A., Sereno, A. J., Richardson-Burns, S., Martin, D., & Carmena, J. M. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2109399 · Cited by 319
“It should be noted that the IrOx used in this work was electroplated and activated IrOx (AIROF) or sputtered IrOx (SIROF) might lead to different results.”
BackgroundInfluentialSensory feedback for limb prostheses in amputees
Raspopovic, S., Valle, G., & Petrini, F. M. (2021) · Nature Materials · doi:10.1038/s41563-021-00966-9 · Cited by 308
Boehler, C., Carli, S., Fadiga, L., Stieglitz, T., & Asplund, M. (2020) · Nature Protocols · doi:10.1038/s41596-020-0389-2 · Cited by 308
Metadata
- Authors
- Negi, S., Bhandari, R., Rieth, L., & Solzbacher, F.
- Venue
- Biomedical Materials
- Publisher
- IOP Publishing
- Published
- 2010-02
- Volume
- 5
- Issue
- 1
- Pages
- 015007
- ISSN
- 1748-6041 (ISSN-L)
- 1748-605X
- OpenAlex
- W2019170895
- Cited by
- 201
- References
- 37
- FWCI
- 3.75
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.