In vitro comparison of sputtered iridium oxide and platinum-coated neural implantable microelectrode arrays
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
Neural interfaces connect signal processing electronics to the nervous system via implanted microelectrode arrays such as the Utah electrode array (UEA). The active sites of the UEA are coated with thin films of either platinum (Pt) or iridium oxide (IrOx). Pt and IrOx have attracted attention as a stimulating or recording material due to their ability to transfer between ionic and electronic current and to resist corrosion. The physical, mechanical, chemical, electrical and optical properties of thin films depend on the method and deposition parameters used to deposit the films. In this work, surface morphology, impedance and charge capacity of Pt and sputtered iridium oxide film (SIROF) were investigated and compared with each other. UEAs with similar electrode area and shape were employed in this study. DC sputtering was used to deposit Pt films and pulsed-dc reactive sputtering was used to deposit SIROF. The electrodes coated with SIROF and Pt were characterized by scanning electron microscopy, cyclic voltammetry, electrochemical impedance spectroscopy and potential transient measurements to measure charge injection capacity (CIC). SIROF and Pt selectively deposited on the electrode tip had dendrite and granular microstructure, respectively. The CIC of unbiased SIROF and Pt was 2 and 0.3 mC cm(-2), respectively. The average impedance at 1 kHz, of SIROF and Pt electrodes, was 6 kOmega and 125 kOmega, respectively. Low impedance and high CIC make SIROF promising stimulation/recording material for neural prosthetic applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thornton, J. A. (1974) · Journal of Vacuum Science and Technology · doi:10.1116/1.1312732 · Cited by 2,421 · cited 1×
“Different deposition methods like dc reactive sputtering [5, 6] and dc reactive magnetron sputtering [7] and deposition parameters like substrate bias [8], apparatus geometry [9], gas flow [10] and pressure [11] yield different degrees of porosity, roughness [12] and thickness, which in turn affect thin film propertie…”
MethodNeural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243 · cited 2×
“20% iridium) no significant change was observed [15, 35].”
BackgroundMethodConducting polymers in biomedical engineering
Guimard, N. K., Gomez, N., & Schmidt, C. E. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.012 · Cited by 1,599
Conjugated Polymer Actuators for Biomedical Applications
Smela, E. (2003) · Advanced Materials · doi:10.1002/adma.200390113 · Cited by 1,177 · cited 1×
“physiologically active species to enhance the biocompatibility and the functionality of the electrodes [26, 27].”
BackgroundCampbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881
Conducting‐Polymer Nanotubes for Controlled Drug Release
Abidian, M. R., Kim, D. ‐., & Martin, D. C. (2006) · Advanced Materials · doi:10.1002/adma.200501726 · Cited by 869 · cited 3×
“These properties of PEDOT make it of intense interest in biomedical applications [29].”
BackgroundCharge density and charge per phase as cofactors in neural injury induced by electrical stimulation
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102812 · Cited by 708 · cited 1×
“The neural damage threshold is roughly 1 mC cm−2 [36].”
BackgroundMultifunctional Nanobiomaterials for Neural Interfaces
Abidian, M. R., & Martin, D. C. (2009) · Advanced Functional Materials · doi:10.1002/adfm.200801473 · Cited by 416 · cited 1×
“Abidian et al [37] deposited PEDOT nanotubes (NT) on planar neural electrodes and calculated the CSC and impedance to be ∼110 mC cm−2 and ∼10 k at 1 kHz, respectively.”
BackgroundAnodic Iridium Oxide Films: XPS‐Studies of Oxidation State Changes and
Kötz, R., Neff, H., & Stucki, S. (1984) · Journal of The Electrochemical Society · doi:10.1149/1.2115548 · Cited by 404
In vitro electrical properties for iridium oxide versus titanium nitride stimulating electrodes
Weiland, J. D., Anderson, D. J., & Humayun, M. S. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.805487 · Cited by 382 · cited 4×
“The CSC of any material can be increased by increasing the surface area and thicknesses of the films but does not guarantee increase in the CIC of that material [25].”
BackgroundInfluential
Cited by
Intracortical microstimulation of human somatosensory cortex
Flesher, S. N., Collinger, J. L., Foldes, S. T., Weiss, J. M., Downey, J. E., Tyler-Kabara, E. C., Bensmaia, S. J., Schwartz, A. B., Boninger, M. L., & Gaunt, R. A. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf8083 · Cited by 704
Progress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384
“(45) Furthermore, conformal ParyleneC coatings have been applied through chemical vapor deposition to provide additional insulation to the electrode tines and protect the underlying dielectrics from dissolution.”
MethodIn Vitro and In Vivo Evaluation of PEDOT Microelectrodes for Neural Stimulation and Recording
Venkatraman, S., Hendricks, J., King, Z. A., Sereno, A. J., Richardson-Burns, S., Martin, D., & Carmena, J. M. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2109399 · Cited by 319
“It should be noted that the IrOx used in this work was electroplated and activated IrOx (AIROF) or sputtered IrOx (SIROF) might lead to different results.”
BackgroundInfluentialSensory feedback for limb prostheses in amputees
Raspopovic, S., Valle, G., & Petrini, F. M. (2021) · Nature Materials · doi:10.1038/s41563-021-00966-9 · Cited by 308
Boehler, C., Carli, S., Fadiga, L., Stieglitz, T., & Asplund, M. (2020) · Nature Protocols · doi:10.1038/s41596-020-0389-2 · Cited by 308
Highly stable carbon nanotube doped poly(3,4-ethylenedioxythiophene) for chronic neural stimulation
Luo, X., Weaver, C. L., Zhou, D. D., Greenberg, R., & Cui, X. T. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.04.051 · Cited by 252
Fernández, E., Alfaro, A., Soto-Sánchez, C., Gonzalez-Lopez, P., Lozano, A. M., Peña, S., Grima, M. D., Rodil, A., Gómez, B., Chen, X., et al. (2021) · Journal of Clinical Investigation · doi:10.1172/jci151331 · Cited by 246
State-of-the-art MEMS and microsystem tools for brain research
Seymour, J. P., Wu, F., Wise, K. D., & Yoon, E. (2017) · Microsystems & Nanoengineering · doi:10.1038/micronano.2016.66 · Cited by 216
Recent Advances in Materials, Devices, and Systems for Neural Interfaces
Won, S. M., Song, E., Zhao, J., Li, J., Rivnay, J., & Rogers, J. A. (2018) · Advanced Materials · doi:10.1002/adma.201800534 · Cited by 206
Chronic in vivo stability assessment of carbon fiber microelectrode arrays
Patel, P. R., Zhang, H., Robbins, M. T., Nofar, J. B., Marshall, S. P., Kobylarek, M. J., Kozai, T. D. Y., Kotov, N. A., & Chestek, C. A. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/066002 · Cited by 204
“We propose a more nuanced model, which argues that even the largest of glial scars cannot fully account for the impedance rise seen in implanted Utah arrays [68], which are made of stable materials [69], have similar impedance values to the carbon fiber arrays, and in our own case where the carbon fibers do not create…”
BackgroundClinical applications of penetrating neural interfaces and Utah Electrode Array technologies
Normann, R. A., & Fernandez, E. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/061003 · Cited by 135
Kim, S., Callier, T., Tabot, G. A., Gaunt, R. A., Tenore, F. V., & Bensmaia, S. J. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1509265112 · Cited by 125
Explant Analysis of Utah Electrode Arrays Implanted in Human Cortex for Brain-Computer-Interfaces
Woeppel, K., Hughes, C., Herrera, A. J., Eles, J. R., Tyler-Kabara, E. C., Gaunt, R. A., Collinger, J. L., & Cui, X. T. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.759711 · Cited by 90
“Both arrays in P1 and two of the arrays in the P2 had platinum (Pt) tips and were used for recording only, while the other two of the arrays in P2 had sputtered iridium oxide (IrOx) tips and were used for both stimulating and recording (Negi et al., 2010).”
BackgroundMethodResultInfluentialThe effects of chronic intracortical microstimulation on neural tissue and fine motor behavior
Rajan, A. T., Boback, J. L., Dammann, J. F., Tenore, F. V., Wester, B. A., Otto, K. J., Gaunt, R. A., & Bensmaia, S. J. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/6/066018 · Cited by 76
Neural interfaces engineered via micro- and nanostructured coatings
Chen, N., Tian, L., Patil, A. C., Peng, S., Yang, I. H., Thakor, N. V., & Ramakrishna, S. (2017) · Nano Today · doi:10.1016/j.nantod.2017.04.007 · Cited by 74
A wafer-scale etching technique for high aspect ratio implantable MEMS structures
Bhandari, R., Negi, S., Rieth, L., & Solzbacher, F. (2010) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2010.06.011 · Cited by 71
“) coated on the tips of the electrode affects the electrical properties such as impedance [18-20], the uniformity in electrical properties is directly influenced by the geometry of the electrodes.”
BackgroundSelf-citationSeidl, K., Herwik, S., Torfs, T., Neves, H. P., Paul, O., & Ruther, P. (2011) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2011.2167661 · Cited by 68
Sponheim, C., Papadourakis, V., Collinger, J. L., Downey, J., Weiss, J., Pentousi, L., Elliott, K., & Hatsopoulos, N. G. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac3eaf · Cited by 66
“The option to use iridium oxide metallization was made available in 2009 which allowed for chronic stimulation due to its improved charge injection capacity, as well as recording (iridium oxide arrays were used for acute stimulation in our lab but were not used for chronic stimulation) [29].”
MethodThe effect of chronic intracortical microstimulation on the electrode–tissue interface
Chen, K. H., Dammann, J. F., Boback, J. L., Tenore, F. V., Otto, K. J., Gaunt, R. A., & Bensmaia, S. J. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026004 · Cited by 59
“While SIROF electrodes have been tested in vitro [19, 20], their safety and performance have yet to be extensively tested in vivo.”
BackgroundLee, Y. J., Kim, H.-J., Do, S. H., Kang, J. Y., & Lee, S. H. (2016) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.06.169 · Cited by 54
Yin, P., Liu, Y., Xiao, L., & Zhang, C. (2021) · Polymers · doi:10.3390/polym13162834 · Cited by 42
Byun, D., Cho, S. J., & Kim, S. (2013) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/23/12/125010 · Cited by 39
Recording nerve signals in canine sciatic nerves with a flexible penetrating microelectrode array
Byun, D., Cho, S.-J., Lee, B. H., Min, J., Lee, J.-H., & Kim, S. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa7493 · Cited by 23
“The measured impedance of the FPMA assembly was in an acceptable range, although it was slightly higher than the values reported in other studies [53, 59] that applied sputtered iridium oxide film (SIROF).”
MethodResultA computational model that predicts behavioral sensitivity to intracortical microstimulation
Kim, S., Callier, T., & Bensmaia, S. J. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/14/1/016012 · Cited by 21
Ereifej, E. S., Cheng, M. M.-C., Mao, G., & VandeVord, P. J. (2013) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2013.04.023 · Cited by 19
Metadata
- Authors
- Negi, S., Bhandari, R., Rieth, L., & Solzbacher, F.
- Venue
- Biomedical Materials
- Publisher
- IOP Publishing
- Published
- 2010-02
- Volume
- 5
- Issue
- 1
- Pages
- 015007
- ISSN
- 1748-6041 (ISSN-L)
- 1748-605X
- OpenAlex
- W2019170895
- Cited by
- 201
- References
- 37
- FWCI
- 3.75
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.