Is breath acetone a biomarker of diabetes? A historical review on breath acetone measurements
The DOI matches its Crossref record; 102 of the 102 references it cites were found in a registry or an index.
Abstract
Since the ancient discovery of the 'sweet odor' in human breath gas, pursuits of the breath analysis-based disease diagnostics have never stopped. Actually, the 'smell' of the breath, as one of three key disease diagnostic techniques, has been used in Eastern-Medicine for more than three thousand years. With advancement of measuring technologies in sensitivity and selectivity, more specific breath gas species have been identified and established as a biomarker of a particular disease. Acetone is one of the breath gases and its concentration in exhaled breath can now be determined with high accuracy using various techniques and methods. With the worldwide prevalence of diabetes that is typically diagnosed through blood testing, human desire to achieve non-blood based diabetic diagnostics and monitoring has never been quenched. Questions, such as is breath acetone a biomarker of diabetes and how is the breath acetone related to the blood glucose (BG) level (the golden criterion currently used in clinic for diabetes diagnostic, monitoring, and management), remain to be answered. A majority of current research efforts in breath acetone measurements and its technology developments focus on addressing the first question. The effort to tackle the second question has begun recently. The earliest breath acetone measurement in clearly defined diabetic patients was reported more than 60 years ago. For more than a half-century, as reviewed in this paper, there have been more than 41 independent studies of breath acetone using various techniques and methods, and more than 3211 human subjects, including 1581 healthy people, 242 Type 1 diabetic patients, 384 Type 2 diabetic patients, 174 unspecified diabetic patients, and 830 non-diabetic patients or healthy subjects who are under various physiological conditions, have been used in the studies. The results of the breath acetone measurements collected in this review support that many conditions might cause changes to breath acetone concentrations; however, the results from the six independent studies using clearly-defined Type 1 and Type 2 diabetic patients unanimously support that an elevated mean breath acetone concentration exists in Type 1 diabetes. Note that there is some overlap between the ranges of breath acetone concentration in individual T1D patients and healthy subjects; this reminds one to be careful when using an acetone breath test on T1D diagnostics. Comparatively, it is too early to draw a general conclusion on the relationship between a breath acetone level and a BG level from the very limited data in the literature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diagnosis and Classification of Diabetes Mellitus
American Diabetes Association (2011) · Diabetes Care · doi:10.2337/dc11-s062 · Cited by 13,988
Biomarkers and surrogate endpoints: Preferred definitions and conceptual framework
(2001) · Clinical Pharmacology & Therapeutics · doi:10.1067/mcp.2001.113989 · Cited by 6,762
Diagnosis and classification of diabetes mellitus
American Diabetes Association (2010) · Diabetes Care · doi:10.2337/dc10-s062 · Cited by 5,491
International Expert Committee report on the role of the A1c assay in the diagnosis of diabetes
The International Expert Committee (2009) · Diabetes Care · doi:10.2337/dc09-9033 · Cited by 3,185
Criteria for screening tests for gestational diabetes
Carpenter, M. W., & Coustan, D. R. (1982) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(82)90349-0 · Cited by 1,924
Unwin, N. C. (2006) · Cited by 1,661
Lindinger, W., Hansel, A., & Jordan, A. (1998) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00281-4 · Cited by 1,615
Quantitative Analysis of Urine Vapor and Breath by Gas-Liquid Partition Chromatography
Pauling, L., Robinson, A. B., Teranishi, R., & Cary, P. (1971) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.68.10.2374 · Cited by 1,025
Report of the Committee on the classification and diagnostic criteria of diabetes mellitus
Kuzuya, T., Nakagawa, S., Satoh, J., Kanazawa, Y., Iwamoto, Y., Kobayashi, M., Nanjo, K., Sasaki, A., Seino, Y., Ito, C., et al. (2002) · Diabetes Research and Clinical Practice · doi:10.1016/s0168-8227(01)00365-5 · Cited by 778
Noninvasive detection of lung cancer by analysis of exhaled breath
Bajtarevic, A., Ager, C., Pienz, M., Klieber, M., Schwarz, K., Ligor, M., Ligor, T., Filipiak, W., Denz, H., Fiegl, M., et al. (2009) · BMC Cancer · doi:10.1186/1471-2407-9-348 · Cited by 597
Wang, C., & Sahay, P. (2009) · Sensors · doi:10.3390/s91008230 · Cited by 596
Self-citationDeng, C., ZHANG, J., Xiang, Y., Zhang, W., & ZHANG, X. (2004) · Journal of Chromatography B · doi:10.1016/j.jchromb.2004.08.013 · Cited by 590
Turner, C., Španěl, P., & Smith, D. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/4/001 · Cited by 379
Current status of clinical breath analysis
Risby, T. H., & Solga, S. F. (2006) · Applied Physics B · doi:10.1007/s00340-006-2280-4 · Cited by 363
Simultaneous measurement of eight foreign gases in blood by gas chromatography
Wagner, P. D., Naumann, P. F., & Laravuso, R. B. (1974) · Journal of Applied Physiology · doi:10.1152/jappl.1974.36.5.600 · Cited by 360
Ferroelectric WO3 Nanoparticles for Acetone Selective Detection
Wang, L., Teleki, A., Pratsinis, S. E., & Gouma, P. I. (2008) · Chemistry of Materials · doi:10.1021/cm800761e · Cited by 357
Progress in SIFT‐MS: Breath analysis and other applications
Španěl, P., & Smith, D. (2011) · Mass Spectrometry Reviews · doi:10.1002/mas.20303 · Cited by 336
Breath acetone monitoring by portable Si:WO3 gas sensors
Righettoni, M., Tricoli, A., Gass, S., Schmid, A., Amann, A., & Pratsinis, S. E. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.06.002 · Cited by 317
Solid-Phase Microextraction for the Analysis of Human Breath
Grote, C., & Pawliszyn, J. (1997) · Analytical Chemistry · doi:10.1021/ac960749l · Cited by 300
Isoprene and acetone concentration profiles during exercise on an ergometer
King, J., Kupferthaler, A., Unterkofler, K., Koc, H., Teschl, S., Teschl, G., Miekisch, W., Schubert, J., Hinterhuber, H., & Amann, A. (2009) · Journal of Breath Research · doi:10.1088/1752-7155/3/2/027006 · Cited by 278
The metabolism of acetone in rat.
Casazza, J. P., Felver, M. E., & Veech, R. L. (1984) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(17)43646-5 · Cited by 260
Jordan, A., Haidacher, S., Hanel, G., Hartungen, E., Herbig, J., Märk, L., Schottkowsky, R., Seehauser, H., Sulzer, P., & Märk, T. D. (2009) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2009.06.006 · Cited by 249
Diskin, A. M., pan l, P., & Smith, D. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/1/308 · Cited by 237
Wang, C., Mbi, A., & Shepherd, M. (2010) · IEEE Sensors Journal · doi:10.1109/jsen.2009.2035730 · Cited by 236
Self-citationIon mobility spectrometry: a review. Part 1. Structural analysis by mobility measurement
Creaser, C. S., Griffiths, J. R., Bramwell, C. J., Noreen, S., Hill, C. A., & Thomas, C. L. P. (2004) · The Analyst · doi:10.1039/b404531a · Cited by 235
SIFT studies of the reactions of H3O+, NO+ and O2+ with a series of alcohols
Spanel, P., & Smith, D. (1997) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00085-2 · Cited by 231
Breath Ethanol and Acetone as Indicators of Serum Glucose Levels: An Initial Report
Galassetti, P. R., Novak, B., Nemet, D., Rose-Gottron, C., Cooper, D. M., Meinardi, S., Newcomb, R., Zaldivar, F., & Blake, D. R. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.115 · Cited by 229
Puavilai, G., Chanprasertyotin, S., & Sriphrapradaeng, A. (1999) · Diabetes Research and Clinical Practice · doi:10.1016/s0168-8227(99)00008-x · Cited by 221
Breath acetone is a reliable indicator of ketosis in adults consuming ketogenic meals,,
Musa-Veloso, K., Likhodii, S. S., & Cunnane, S. C. (2002) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/76.1.65 · Cited by 218
Popov, T. A. (2011) · Annals of Allergy, Asthma & Immunology · doi:10.1016/j.anai.2011.02.016 · Cited by 206
The clinical potential of exhaled breath analysis for diabetes mellitus
Minh, T. D. C., Blake, D. R., & Galassetti, P. R. (2012) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2012.02.006 · Cited by 200
Rudnicka, J., Kowalkowski, T., Ligor, T., & Buszewski, B. (2011) · Journal of Chromatography B · doi:10.1016/j.jchromb.2011.09.001 · Cited by 194
Acetone metabolism during diabetic ketoacidosis
Owen, O. E., Trapp, V. E., Skutches, C. L., Mozzoli, M. A., Hoeldtke, R. D., Boden, G., & Reichard, G. A. (1982) · Diabetes · doi:10.2337/diab.31.3.242 · Cited by 190
Point-of-care breath test for biomarkers of active pulmonary tuberculosis
Phillips, M., Basa-Dalay, V., Blais, J., Bothamley, G., Chaturvedi, A., Modi, K. D., Pandya, M., Natividad, M. P. R., Patel, U., Ramraje, N. N., et al. (2012) · Tuberculosis · doi:10.1016/j.tube.2012.04.002 · Cited by 190
Turner, C., Walton, C., Hoashi, S., & Evans, M. (2009) · Journal of Breath Research · doi:10.1088/1752-7155/3/4/046004 · Cited by 183
Current status of midinfrared quantum and interband cascade lasers for clinical breath analysis
Tittel, F. K. (2010) · Optical Engineering · doi:10.1117/1.3498768 · Cited by 181
Volatile organic compounds in the exhaled breath of young patients with cystic fibrosis
Barker, M., Hengst, M., Schmid, J., Buers, H.-J., Mittermaier, B., Klemp, D., & Koppmann, R. (2006) · European Respiratory Journal · doi:10.1183/09031936.06.00085105 · Cited by 181
Smith, D., Spanel, P., & Davies, S. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.5.1584 · Cited by 180
Determination and prediction of tissue-gas partition coefficients
Fiserova-Bergerova, V., & Diaz, M. L. (1986) · International Archives of Occupational and Environmental Health · doi:10.1007/bf00378543 · Cited by 180
Williams, J., Pöschl, U., Crutzen, P. J., Hansel, A., Holzinger, R., Warneke, C., Lindinger, W., & Lelieveld, J. (2001) · Journal of Atmospheric Chemistry · doi:10.1023/a:1006322701523 · Cited by 170
BREATH-ACETONE AND BLOOD-SUGAR MEASUREMENTS IN DIABETES
Tassopoulos, C. N., Barnett, D., & Russell Fraser, T. (1969) · The Lancet · doi:10.1016/s0140-6736(69)92222-3 · Cited by 169
Lawson, L. D., & Wang, Z. J. (2005) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf048323s · Cited by 167
Self-citationSchwarz, K., Pizzini, A., Arendacká, B., Zerlauth, K., Filipiak, W., Schmid, A., Dzien, A., Neuner, S., Lechleitner, M., Scholl-Bürgi, S., et al. (2009) · Journal of Breath Research · doi:10.1088/1752-7155/3/2/027003 · Cited by 164
Analysis of breath, exhaled via the mouth and nose, and the air in the oral cavity
Wang, T., Pysanenko, A., Dryahina, K., Španěl, P., & Smith, D. (2008) · Journal of Breath Research · doi:10.1088/1752-7155/2/3/037013 · Cited by 164
Plasma Acetone Metabolism in the Fasting Human
Reichard, G. A., Haff, A. C., Skutches, C. L., Paul, P., Holroyde, C. P., & Owen, O. E. (1979) · Journal of Clinical Investigation · doi:10.1172/jci109344 · Cited by 156
Ligor, T., Ligor, M., Amann, A., Ager, C., Bachler, M., Dzien, A., & Buszewski, B. (2008) · Journal of Breath Research · doi:10.1088/1752-7155/2/4/046006 · Cited by 149
A novel method for diabetes diagnosis based on electronic nose
Wang, P., Yi, T., Haibao, X., & Farong, S. (1997) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(97)00059-6 · Cited by 146
Measurement of endogenous acetone and isoprene in exhaled breath during sleep
King, J., Kupferthaler, A., Frauscher, B., Hackner, H., Unterkofler, K., Teschl, G., Hinterhuber, H., Amann, A., & Högl, B. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/3/413 · Cited by 144
Ueta, I., Saito, Y., Hosoe, M., Okamoto, M., Ohkita, H., Shirai, S., Tamura, H., & Jinno, K. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2009.06.039 · Cited by 136
Turner, C., Parekh, B. K., Walton, C., Španěl, P., Smith, D. C., & Evans, M. L. (2008) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3402 · Cited by 135
Determination of acetone in breath
Teshima, N., Li, J., Toda, K., & Dasgupta, P. Κ. (2005) · Analytica Chimica Acta · doi:10.1016/j.aca.2004.12.018 · Cited by 133
Glycated haemoglobin (HbA1c) for the diagnosis of diabetes mellitus—Practical implications
Colagiuri, S. (2011) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2011.06.025 · Cited by 126
Direct, rapid quantitative analyses of BVOCs using SIFT-MS and PTR-MS obviating sample collection
Smith, D. C., & Španěl, P. (2011) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2011.05.001 · Cited by 122
King, J., Unterkofler, K., Teschl, G., Teschl, S., Koc, H., Hinterhuber, H., & Amann, A. (2011) · Journal of Mathematical Biology · doi:10.1007/s00285-010-0398-9 · Cited by 117
Acetone, ammonia and hydrogen cyanide in exhaled breath of several volunteers aged 4–83 years
Španěl, P., Dryahina, K., & Smith, D. C. (2007) · Journal of Breath Research · doi:10.1088/1752-7155/1/1/011001 · Cited by 116
Measuring airway exchange of endogenous acetone using a single-exhalation breathing maneuver
Anderson, J. C., Lamm, W. J. E., & Hlastala, M. P. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00868.2005 · Cited by 116
Minh, T. D. C., Oliver, S. R., Ngo, J., Flores, R. L., Midyett, J., Meinardi, S., Carlson, M. K., Rowland, F. S., Blake, D. R., & Galassetti, P. R. (2011) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00634.2010 · Cited by 115
Can volatile compounds in exhaled breath be used to monitor control in diabetes mellitus?
Smith, D. C., Španěl, P., Fryer, A. A., Hanna, F., & Ferns, G. A. (2011) · Journal of Breath Research · doi:10.1088/1752-7155/5/2/022001 · Cited by 114
Non-invasive blood glucose monitoring for diabetics by means of breath signal analysis
Guo, D., Zhang, D. D., Zhang, L., & Lu, G. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.06.025 · Cited by 113
Breath acetone predicts plasma ketone bodies in children with epilepsy on a ketogenic diet
Musa‐Veloso, K., Likhodii, S. S., Rarama, E., Benoit, S., Liu, Y.-M. C., Chartrand, D. J., Curtis, R., Carmant, L., Lortie, A., Comeau, F. J. E., et al. (2005) · Nutrition · doi:10.1016/j.nut.2005.04.008 · Cited by 109
Nanosensor Device for Breath Acetone Detection
Wang, L., Kalyanasundaram, K., Stanaćević, M., & Gouma, P. (2010) · Sensor Letters · doi:10.1166/sl.2010.1334 · Cited by 106
Exhaled Acetone as a New Biomarker of Heart Failure Severity
Marcondes‐Braga, F. G., Gutz, I. G. R., Batista, G. L., Saldiva, P. H. N., Ayub‐Ferreira, S. M., Issa, V. S., Mangini, S., Bocchi, E. A., & Bacal, F. (2012) · CHEST Journal · doi:10.1378/chest.11-2892 · Cited by 103
WO3 nanocrystals: Synthesis and application in highly sensitive detection of acetone
Shi, J., Hu, G., Sun, Y., Geng, M., Wu, J., Liu, Y., Ge, M., Tao, J., Cao, M., & Dai, N. (2011) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.02.047 · Cited by 101
Pabst, F., Miekisch, W., Fuchs, P., Kischkel, S., & Schubert, J. K. (2007) · Journal of Cardiothoracic Surgery · doi:10.1186/1749-8090-2-37 · Cited by 100
Exhaled Isoprene and Acetone in Newborn Infants and in Children with Diabetes Mellitus
Nelson, N., Lagesson, V., Nosratabadi, A. R., Ludvigsson, J., & Tagesson, C. (1998) · Pediatric Research · doi:10.1203/00006450-199809000-00016 · Cited by 98
O’Hara, M. E., Clutton-Brock, T. H., Green, S., & Mayhew, C. A. (2009) · Journal of Breath Research · doi:10.1088/1752-7155/3/2/027005 · Cited by 94
Phase-resolved real-time breath analysis during exercise by means of smart processing of PTR-MS data
Schwoebel, H., Schubert, R., Sklorz, M., Kischkel, S., Zimmermann, R., Schubert, J. K., & Miekisch, W. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-5173-2 · Cited by 94
Breath acetone in congestive heart failure
Kupari, M. M., Lommi, J., Ventilä, M., & Karjalainen, U. P. (1995) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)80304-x · Cited by 87
Selective acetone gas sensors using porous WO3–Cr2O3 thin films prepared by sol–gel method
Gao, P. Z., Ji, H., Zhou, Y., & Li, X. (2011) · Thin Solid Films · doi:10.1016/j.tsf.2011.12.003 · Cited by 85
Breath tests and airway gas exchange
Anderson, J. C., & Hlastala, M. P. (2006) · Pulmonary Pharmacology & Therapeutics · doi:10.1016/j.pupt.2005.12.002 · Cited by 83
Possible physiological roles of acetone metabolism in humans
Kalapos, M. P. (1999) · Medical Hypotheses · doi:10.1054/mehy.1998.0752 · Cited by 80
Human breath analysis: methods for sample collection and reduction of localized background effects
Martin, A. N., Farquar, G. R., Jones, A. D., & Frank, M. A. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-3217-7 · Cited by 79
The concentration distributions of some metabolites in the exhaled breath of young adults
Španěl, P., Dryahina, K., & Smith, D. C. (2007) · Journal of Breath Research · doi:10.1088/1752-7155/1/2/026001 · Cited by 78
Highly sensitive and selective sensors to volatile organic compounds using MWCNTs/SnO2
Ahmadnia-Feyzabad, S., Khodadadi, A. A., Vesali‐Naseh, M., & Mortazavi, Y. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.02.024 · Cited by 78
Enderby, B., Lenney, W., Brady, M., Emmett, C., Španěl, P., & Smith, D. C. (2009) · Journal of Breath Research · doi:10.1088/1752-7155/3/3/036001 · Cited by 74
Storer, M., Dummer, J. F., Lunt, H., Scotter, J., McCartin, F., Cook, J., Swanney, M. P., Kendall, D., Logan, F. J., & Epton, M. (2011) · Journal of Breath Research · doi:10.1088/1752-7155/5/4/046011 · Cited by 73
Wang, C., & Surampudi, A. B. (2008) · Measurement Science and Technology · doi:10.1088/0957-0233/19/10/105604 · Cited by 69
Self-citationPure and Pt-loaded gamma iron oxide as sensor for detection of sub ppm level of acetone
Biswal, R. C. (2011) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.03.047 · Cited by 67
Differences in Exhaled Gas Profiles Between Patients with Type 2 Diabetes and Healthy Controls
Greiter, M. B., Keck, L., Siegmund, T., Hoeschen, C., Oeh, U., & Paretzke, H. G. (2010) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0181 · Cited by 61
Potential of breath and skin analysis for monitoring blood glucose concentration in diabetes
Turner, C. (2011) · Expert Review of Molecular Diagnostics · doi:10.1586/erm.11.31 · Cited by 61
Epilepsy and the Ketogenic Diet: Assessment of Ketosis in Children Using Breath Acetone
Musa‐Veloso, K., Rarama, E., Comeau, F. J. E., Curtis, R., & Cunnane, S. C. (2002) · Pediatric Research · doi:10.1203/00006450-200209000-00023 · Cited by 58
Quantitative analysis of trace gases of breath during exercise using the new SIFT–MS technique
Senthilmohan, S. T., Milligan, D. B., McEwan, M. J., Freeman, C. G., & Wilson, P. F. (2000) · Redox Report · doi:10.1179/135100000101535537 · Cited by 57
Hryniuk, A., & Ross, B. M. (2009) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2009.02.027 · Cited by 54
Boshier, P. R., Marczin, N., & Hanna, G. B. (2010) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2010.02.008 · Cited by 53
Schiller, B., Hammer, J., Barben, J., & Trachsel, D. (2009) · Pediatric Allergy and Immunology · doi:10.1111/j.1399-3038.2009.00853.x · Cited by 50
Mukhopadhyay, R. (2008) · Analytical Chemistry · doi:10.1021/ac8018608 · Cited by 50
Diskin, A. M., Spanel, P., & Smith, D. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/1/314 · Cited by 46
Wang, C., & Mbi, A. (2007) · Measurement Science and Technology · doi:10.1088/0957-0233/18/8/051 · Cited by 42
Self-citationHuman Breath Gas Analysis in the Screening of Gestational Diabetes Mellitus
Halbritter, S., Fedrigo, M., Höllriegl, V., Szymczak, W., Maier, J. M., Ziegler, A., & Hummel, M. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2012.0076 · Cited by 42
Acetone and Isoprene Concentrations in Exhaled Breath in Healthy Subjects
Kinoyama, M., Nitta, H., Watanabe, A., & UEDA, H. M. D. (2008) · Eisei kagaku · doi:10.1248/jhs.54.471 · Cited by 41
Dummer, J. F., Storer, M., Hu, W.-P., Swanney, M. P., Milne, G. J., FRAMPTON, C. M. A., Scotter, J., Prisk, G. K., & Epton, M. (2010) · Journal of Breath Research · doi:10.1088/1752-7155/4/4/046001 · Cited by 39
KIM, S., Moon, J., Kwak, H. J., Kim, S. I., Park, D. W., Kim, J. W., Kim, T., Sohn, J. W., Shin, D. H., Park, S. S., et al. (2012) · Respirology · doi:10.1111/j.1440-1843.2012.02163.x · Cited by 37
Nanoparticle-structured thin film sensor arrays for breath sensing
Luo, J., Luo, J., Wang, L., Shi, X., Yin, J., Crew, E., Lu, S. F., Lesperance, L. M., & Zhong, C. (2011) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.11.045 · Cited by 37
CURRENT STATUS OF CLINICAL BREATH ANALYSIS
Risby, T. H. (2005) · doi:10.1142/9789812701954_0017 · Cited by 35
Toda, K., Koga, T., Kosuge, J., Kashiwagi, M., Oguchi, H., & Arimoto, T. (2009) · Analytical Chemistry · doi:10.1021/ac901131d · Cited by 34
Davis, C. E., Bogan, M. J., Sankaran, S., Molina, M. A., Loyola, B. R., Zhao, W., Benner, W. H., Schivo, M., Farquar, G. R., Kenyon, N. J., et al. (2009) · IEEE Sensors Journal · doi:10.1109/jsen.2009.2033562 · Cited by 33
Wang, T., Španěl, P., & Smith, D. C. (2008) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2008.01.002 · Cited by 27
O’Hara, M. E., Clutton-Brock, T. H., Green, S., O'Hehir, S., & Mayhew, C. A. (2008) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2008.12.005 · Cited by 26
7.1.3 Breath acetone monitoring by portable Si:WO3 gas sensors
Righettoni, M., Tricoli, A., Gass, S., Pratsinis, S. E., Schmid, A., & Amann, A. (2012) · Proceedings IMCS 2012 · doi:10.5162/imcs2012/7.1.3 · Cited by 24
Bloor, R. N., Španěl, P., & Smith, D. C. (2006) · Addiction Biology · doi:10.1111/j.1369-1600.2006.00015.x · Cited by 22
Laakso, O., Haapala, M., Kuitunen, T., & Himberg, J. (2004) · Journal of Analytical Toxicology · doi:10.1093/jat/28.2.111 · Cited by 15
Alberti (1998) · doi:10.1002/(sici)1096-9136(199807)15:7<539::aid-dia668>3.0.co;2-s
Cited by
Supramolecular Luminescent Sensors
Mako, T. L., Racicot, J. M., & Levine, M. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00260 · Cited by 735
Electronic Textiles for Wearable Point-of-Care Systems
Chen, G., Xiao, X., Zhao, X., Tat, T., Bick, M., & Chen, J. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00502 · Cited by 688
Non-Invasive Blood Glucose Monitoring Technology: A Review
Tang, L., Chang, S. J., Chen, C.-J., & Liu, J.-T. (2020) · Sensors · doi:10.3390/s20236925 · Cited by 481
Review—Non-Invasive Monitoring of Human Health by Exhaled Breath Analysis: A Comprehensive Review
Das, S., & Pal, M. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ab67a6 · Cited by 466
W18O49/Ti3C2Tx Mxene nanocomposites for highly sensitive acetone gas sensor with low detection limit
Sun, S., Wang, M., Chang, X., Jiang, Y., Zhang, D., Wang, D., Zhang, Y., & Lei, Y. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2019.127274 · Cited by 338
Metadata
- Authors
- Wang, Z., & Wang, C.
- Venue
- Journal of Breath Research
- Publisher
- IOP Publishing
- Published
- 2013-08-20
- Volume
- 7
- Issue
- 3
- Pages
- 037109
- ISSN
- 1752-7155 (ISSN-L)
- 1752-7163
- OpenAlex
- W2043596117
- Cited by
- 309
- References
- 102
- FWCI
- 5.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.