The DOI matches its Crossref record; 108 of the 108 references it cites were found in a registry or an index.
Non-Invasive Glucose Measurement Technologies: An Update from 1999 to the Dawn of the New Millennium
Abstract
There are three main issues in non-invasive (NI) glucose measurements: namely, specificity, compartmentalization of glucose values, and calibration. There has been progress in the use of near-infrared and mid-infrared spectroscopy. Recently new glucose measurement methods have been developed, exploiting the effect of glucose on erythrocyte scattering, new photoacoustic phenomenon, optical coherence tomography, thermo-optical studies on human skin, Raman spectroscopy studies, fluorescence measurements, and use of photonic crystals. In addition to optical methods, in vivo electrical impedance results have been reported. Some of these methods measure intrinsic properties of glucose; others deal with its effect on tissue or blood properties. Recent studies on skin from individuals with diabetes and its response to stimuli, skin thermo-optical response, peripheral blood flow, and red blood cell rheology in diabetes shed new light on physical and physiological changes resulting from the disease that can affect NI glucose measurements. There have been advances in understanding compartmentalization of glucose values by targeting certain regions of human tissue. Calibration of NI measurements and devices is still an open question. More studies are needed to understand the specific glucose signals and signals that are due to the effect of glucose on blood and tissue properties. These studies should be performed under normal physiological conditions and in the presence of other co-morbidities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Glucose clamp technique: a method for quantifying insulin secretion and resistance.
DeFronzo, R. A., Tobin, J. D., & Andres, R. (1979) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1979.237.3.e214 · Cited by 7,425
Polymerized colloidal crystal hydrogel films as intelligent chemical sensing materials
Holtz, J. H., & Asher, S. A. (1997) · Nature · doi:10.1038/39834 · Cited by 2,004
Optical coherence tomography (OCT): a review
Schmitt, J. M. (1999) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.796348 · Cited by 1,188
Prospects for in vivo Raman spectroscopy
Hanlon, E. B., Manoharan, R., Koo, T.-W., Shafer, K. E., Motz, J. T., Fitzmaurice, M., Kramer, J. R., Itzkan, I., Dasari, R. R., & Feld, M. S. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/2/201 · Cited by 894
Acute Hyperglycemia Attenuates Endothelium-Dependent Vasodilation in Humans In Vivo
Williams, S. B., Goldfine, A. B., Timimi, F. K., Ting, H. H., Roddy, M.-A., Simonson, D. C., & Creager, M. A. (1998) · Circulation · doi:10.1161/01.cir.97.17.1695 · Cited by 796
Plasmon-Sampled Surface-Enhanced Raman Excitation Spectroscopy
Haynes, C. L., & Van Duyne, R. P. (2003) · The Journal of Physical Chemistry B · doi:10.1021/jp027749b · Cited by 696
Toward a Glucose Biosensor Based on Surface-Enhanced Raman Scattering
Shafer-Peltier, K. E., Haynes, C. L., Glucksberg, M. R., & Van Duyne, R. P. (2003) · Journal of the American Chemical Society · doi:10.1021/ja028255v · Cited by 653
Microvascular and macrovascular reactivity is reduced in subjects at risk for type 2 diabetes.
Caballero, A. E., Arora, S., Saouaf, R., Lim, S. C., Smakowski, P., Park, J. Y., King, G. L., LoGerfo, F. W., Horton, E. S., & Veves, A. (1999) · Diabetes · doi:10.2337/diabetes.48.9.1856 · Cited by 648
Salomaa, V., Riley, W., Kark, J. D., Nardo, C., & Folsom, A. R. (1995) · Circulation · doi:10.1161/01.cir.91.5.1432 · Cited by 582
Hyponatremia: evaluating the correction factor for hyperglycemia
Hillier, T. A., Abbott, R. D., & Barrett, E. J. (1999) · The American Journal of Medicine · doi:10.1016/s0002-9343(99)00055-8 · Cited by 567
Photonic Crystal Carbohydrate Sensors: Low Ionic Strength Sugar Sensing
Asher, S. A., Alexeev, V. L., Goponenko, A. V., Sharma, A. C., Lednev, I. K., Wilcox, C. S., & Finegold, D. N. (2003) · Journal of the American Chemical Society · doi:10.1021/ja021037h · Cited by 488
Monnier, V. M., Bautista, O., Kenny, D., Sell, D. R., Fogarty, J., Dahms, W., Cleary, P. A., Lachin, J., & Genuth, S. (1999) · Diabetes · doi:10.2337/diabetes.48.4.870 · Cited by 469
Combined In Vivo Confocal Raman Spectroscopy and Confocal Microscopy of Human Skin
Caspers, P. J., Lucassen, G. W., & Puppels, G. J. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)74501-9 · Cited by 446
Three-dimensional photoacoustic imaging of blood vessels in tissue
Hoelen, C. G. A., de Mul, F. F. M., Pongers, R., & Dekker, A. (1998) · Optics Letters · doi:10.1364/ol.23.000648 · Cited by 446
Multiphoton excitation fluorescence microscopy and spectroscopy of in vivo human skin
Masters, B. R., So, P. T., & Gratton, E. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78886-6 · Cited by 439
High Ionic Strength Glucose-Sensing Photonic Crystal
Alexeev, V. L., Sharma, A. C., Goponenko, A. V., Das, S., Lednev, I. K., Wilcox, C. S., Finegold, D. N., & Asher, S. A. (2003) · Analytical Chemistry · doi:10.1021/ac030021m · Cited by 405
Boyne, M. S., Silver, D. M., Kaplan, J., & Saudek, C. D. (2003) · Diabetes · doi:10.2337/diabetes.52.11.2790 · Cited by 404
Prediction of Clinical Coronary Heart Disease by a Test for the Coronary-Prone Behavior Pattern
Jenkins, C. D., Rosenman, R. H., & Zyzanski, S. J. (1974) · New England Journal of Medicine · doi:10.1056/nejm197406062902301 · Cited by 392
Yonzon, C. R., Haynes, C. L., Zhang, X., Walsh, & Van Duyne, R. P. (2004) · Analytical Chemistry · doi:10.1021/ac035134k · Cited by 376
Optical glucose sensing in biological fluids: an overview
McNichols, R. J., & Coté, G. L. (2000) · Journal of Biomedical Optics · doi:10.1117/1.429962 · Cited by 371
Rebrin, K., Steil, G. M., van Antwerp, W. P., & Mastrototaro, J. J. (1999) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1999.277.3.e561 · Cited by 366
Russell, R. J., Pishko, M. V., Gefrides, C. C., McShane, M. J., & Coté, G. L. (1999) · Analytical Chemistry · doi:10.1021/ac990060r · Cited by 353
Spectroscopic and Clinical Aspects of Noninvasive Glucose Measurements
Khalil, O. S. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.2.165 · Cited by 331
Self-citationMaier, J. S., Walker, S. A., Fantini, S., Franceschini, M. A., & Gratton, E. (1994) · Optics Letters · doi:10.1364/ol.19.002062 · Cited by 318
A General Photonic Crystal Sensing Motif: Creatinine in Bodily Fluids
Sharma, A. C., Jana, T., Kesavamoorthy, R., Shi, L., Virji, M. A., Finegold, D. N., & Asher, S. A. (2004) · Journal of the American Chemical Society · doi:10.1021/ja038187s · Cited by 304
Noninvasive Blood Glucose Monitoring With Optical Coherence Tomography
Larin, K. V., Eledrisi, M. S., Motamedi, M., & Esenaliev, R. O. (2002) · Diabetes Care · doi:10.2337/diacare.25.12.2263 · Cited by 293
Sensors for glucose monitoring: technical and clinical aspects
Koschinsky, T., & Heinemann, L. (2001) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.188 · Cited by 288
Insulin-induced vasodilatation: physiology or pharmacology?
Yki-Järvinen, H., & Utriainen, T. (1998) · Diabetologia · doi:10.1007/s001250050919 · Cited by 261
First human experiments with a novel non-invasive, non-optical continuous glucose monitoring system
Caduff, A., Hirt, E., Feldman, Y., Ali, Z., & Heinemann, L. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00196-9 · Cited by 247
Graaff, R., Aarnoudse, J. G., Zijp, J. R., Sloot, P. M. A., de Mul, F. F. M., Greve, J., & Koelink, M. H. (1992) · Applied Optics · doi:10.1364/ao.31.001370 · Cited by 241
Knüttel, A., & Boehlau-Godau, M. (2000) · Journal of Biomedical Optics · doi:10.1117/1.429972 · Cited by 235
Noninvasive Prediction of Glucose by Near-Infrared Diffuse Reflectance Spectroscopy
Malin, S. F., Ruchti, T. L., Blank, T. B., Thennadil, S. N., & Monfre, S. L. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.9.1651 · Cited by 235
Time domain dielectric spectroscopy study of human cells
Polevaya, Y., Ermolina, I., Schlesinger, M., Ginzburg, B.-Z., & Feldman, Y. (1999) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/s0005-2736(99)00072-3 · Cited by 234
Electromagnetic Mechanism of Surface‐Enhanced Spectroscopy
Schatz, G. C., & Van Duyne, R. P. (2001) · Handbook of Vibrational Spectroscopy · doi:10.1002/0470027320.s0601 · Cited by 225
Haaland, D. M., Easterling, R. G., & Vopicka, D. A. (1985) · Applied Spectroscopy · doi:10.1366/0003702854249376 · Cited by 222
Khan, F., Elhadd, T. A., Greene, S. A., & Belch, J. J. (2000) · Diabetes Care · doi:10.2337/diacare.23.2.215 · Cited by 214
Optical absorptions of light and heavy water by laser optoacoustic spectroscopy
Tam, A. C., & Patel, C. K. N. (1979) · Applied Optics · doi:10.1364/ao.18.003348 · Cited by 206
Noninvasive monitoring of glucose concentration with optical coherence tomography
Esenaliev, R. O., Larin, K. V., Larina, I. V., & Motamedi, M. (2001) · Optics Letters · doi:10.1364/ol.26.000992 · Cited by 204
The development of Biostator, a Glucose Controlled Insulin Infusion System (GCIIS).
Clemens, A. H., Chang, P. H., & Myers, R. W. (1977) · PubMed · Cited by 191
Advances in Photoacoustic Noninvasive Glucose Testing
MacKenzie, H. A., Ashton, H. S., Spiers, S., Shen, Y., Freeborn, S. S., Hannigan, J., Lindberg, J., & Rae, P. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.9.1587 · Cited by 186
Rabinovitch, B., March, W. F., & Adams, R. L. (1982) · Diabetes Care · doi:10.2337/diacare.5.3.254 · Cited by 179
Infrared and raman spectroscopy of carbohydrates
Vasko, P. D., Blackwell, J., & Koenig, J. L. (1971) · Carbohydrate Research · doi:10.1016/s0008-6215(00)86160-1 · Cited by 178
Thennadil, S. N., Rennert, J. L., Wenzel, B. J., Hazen, K. H., Ruchti, T. L., & Block, M. B. (2001) · Diabetes Technology & Therapeutics · doi:10.1089/15209150152607132 · Cited by 166
In Vivo Noninvasive Measurement of Blood Glucose by Near-Infrared Diffuse-Reflectance Spectroscopy
Maruo, K., Tsurugi, M., Tamura, M., & Ozaki, Y. (2003) · Applied Spectroscopy · doi:10.1366/000370203769699090 · Cited by 162
Photonic Crystal Aqueous Metal Cation Sensing Materials
Asher, S. A., Sharma, A. C., Goponenko, A. V., & Ward, M. M. (2003) · Analytical Chemistry · doi:10.1021/ac026328n · Cited by 161
Bruulsema, J. T., Hayward, J. E., Farrell, T. J., Patterson, M. S., Heinemann, L., Berger, M., Koschinsky, T., Sandahl-Christiansen, J., Ørskov, H., Essenpreis, M., et al. (1997) · Optics Letters · doi:10.1364/ol.22.000190 · Cited by 156
Haaland, D. M., & Easterling, R. G. (1982) · Applied Spectroscopy · doi:10.1366/0003702824639114 · Cited by 152
Badugu, R., Lakowicz, J. R., & Geddes, C. D. (2003) · Analytical Chemistry · doi:10.1021/ac0303721 · Cited by 152
Feasibility of measuring blood glucose concentration by near-infrared Raman spectroscopy
Berger, A. J., Itzkan, I., & Feld, M. S. (1997) · Spectrochimica Acta Part A Molecular Spectroscopy · doi:10.1016/s1386-1425(96)01779-9 · Cited by 149
Larin, K. V., Motamedi, M., Ashitkov, T. V., & Esenaliev, R. O. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/10/310 · Cited by 147
Akbari, C. M., Saouaf, R., Barnhill, D. F., Newman, P. A., LoGerfo, F. W., & Veves, A. (1998) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(98)70095-3 · Cited by 146
Dielectric spectroscopy study of specific glucose influence on human erythrocyte membranes
Hayashi, Y., Livshits, L., Caduff, A., & Feldman, Y. D. (2003) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/36/4/307 · Cited by 142
Impaired Peripheral Vasomotion in Diabetes
Stansberry, K. B., Shapiro, S. A., Hill, M. A., McNitt, P. M., Meyer, M. D., & Vinik, A. I. (1996) · Diabetes Care · doi:10.2337/diacare.19.7.715 · Cited by 132
Brancaleon, L., Bamberg, M. P., Sakamaki, T., & Kollias, N. (2001) · Journal of Investigative Dermatology · doi:10.1046/j.1523-1747.2001.01262.x · Cited by 130
Microvascular Blood Flow, Volume, and Velocity Measured by Laser Doppler Techniques in IDDM
Rendell, M., Bergman, T., O'Donnell, G., Drobny, E., Borgos, J., & Bonner, R. F. (1989) · Diabetes · doi:10.2337/diab.38.7.819 · Cited by 125
An Enhanced Algorithm for Linear Multivariate Calibration
Berger, A. J., Koo, T.-W., Itzkan, I., & Feld, M. S. (1998) · Analytical Chemistry · doi:10.1021/ac970721p · Cited by 119
The red blood cell in vascular occlusion
Yedgar, S., Koshkaryev, A., & Barshtein, G. (2002) · Pathophysiology of Haemostasis and Thrombosis · doi:10.1159/000073578 · Cited by 118
Burmeister, J. J., & Arnold, M. A. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.9.1621 · Cited by 110
Jaap, A. J., Hammersley, M. S., Shore, A. C., & Tooke, J. E. (1994) · Diabetologia · doi:10.1007/s001250050096 · Cited by 109
Lucassen, G. W., van Veen, G. N. A., & Jansen, J. A. J. (1998) · Journal of Biomedical Optics · doi:10.1117/1.429890 · Cited by 104
Phantom Glucose Calibration Models from Simulated Noninvasive Human Near-Infrared Spectra
Arnold, M. A., Burmeister, J. J., & Small, G. W. (1998) · Analytical Chemistry · doi:10.1021/ac9710801 · Cited by 100
Burmeister, J. J., Arnold, M. A., & Small, G. W. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/152091500316683 · Cited by 100
Reagentless Near-Infrared Determination of Glucose in Whole Blood Using Multivariate Calibration
Haaland, D. M., Robinson, M., Koepp, G. W., Thomas, E. V., & Eaton, R. P. (1992) · Applied Spectroscopy · doi:10.1366/000370292789619232 · Cited by 99
Swindle, L. D., Thomas, S. G., Freeman, M., & Delaney, P. M. (2003) · Journal of Investigative Dermatology · doi:10.1046/j.1523-1747.2003.12477.x · Cited by 97
A Novel Noninvasive Blood Glucose Monitor
Malchoff, C. D., Shoukri, K., Landau, J. I., & Buchert, J. M. (2002) · Diabetes Care · doi:10.2337/diacare.25.12.2268 · Cited by 96
Development of an Intelligent Polymerized Crystalline Colloidal Array Colorimetric Reagent
Reese, C. E., Baltusavich, M. E., Keim, J. P., & Asher, S. A. (2001) · Analytical Chemistry · doi:10.1021/ac010667j · Cited by 95
McCartney, L. J., Pickup, J. C., Rolinski, O. J., & Birch, D. J. S. (2001) · Analytical Biochemistry · doi:10.1006/abio.2001.5060 · Cited by 94
The Use of Polarized Laser Light Through the Eye for Noninvasive Glucose Monitoring
Cameron, B. D., Gorde, H., Satheesan, B., & Coté, G. L. (1999) · Diabetes Technology & Therapeutics · doi:10.1089/152091599317341 · Cited by 94
Transcutaneous glucose measurement using near-infrared spectroscopy during hypoglycemia.
Gabriely, I., Wozniak, R., Mevorach, M., Kaplan, J., Aharon, Y., & Shamoon, H. (1999) · Diabetes Care · doi:10.2337/diacare.22.12.2026 · Cited by 91
Circadian Periodicity in Some Physicochemical Parameters of Circulating Blood
Seaman, G. V. F., ENGEL, R., SWANK, R. L., & HISSEN, W. (1965) · Nature · doi:10.1038/207833a0 · Cited by 90
Shen, Y., Davies, A. G., Linfield, E. H., Elsey, T. S., Taday, P. F., & Arnone, D. D. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/13/313 · Cited by 89
Non-invasive continuous glucose monitoring in Type I diabetic patients with optical glucose sensors
Heinemann, L., & Schmelzeisen‐Redeker, G. (1998) · Diabetologia · doi:10.1007/s001250050998 · Cited by 85
Yeh, S.-J., Hanna, C. F., & Khalil, O. S. (2003) · Clinical Chemistry · doi:10.1373/49.6.924 · Cited by 80
Self-citationProperties of erythrocyte light refraction in diabetic patients
Mazarevica, G., Freivalds, T., & Jurka, A. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1463043 · Cited by 74
Analysis of dielectric spectra of eukaryotic cells by computer modeling
Ermolina, I., Polevaya, Y., & Feldman, Y. D. (2000) · European Biophysics Journal · doi:10.1007/s002490050259 · Cited by 73
Sibbald, R. G., Landolt, S. J., & Toth, D. P. (1996) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/s0889-8529(05)70334-0 · Cited by 71
Cameron, B. D., Baba, J. S., & Coté, G. L. (2001) · Diabetes Technology & Therapeutics · doi:10.1089/152091501300209552 · Cited by 69
Optical transmission of blood: effect of erythrocyte aggregation
Shvartsman, L. D., & Fine, I. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.814532 · Cited by 65
Koschinsky, T., Jungheim, K., & Heinemann, L. (2003) · Diabetes Technology & Therapeutics · doi:10.1089/152091503322527030 · Cited by 64
Bülow, J., Astrup, A. V., Christensen, N. J., & Kastrup, J. (1987) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1987.tb08189.x · Cited by 62
Measurement of Tissue Optical Properties: Methods and Theories
Wilson, B. C. (1995) · Springer eBooks · doi:10.1007/978-1-4757-6092-7_8 · Cited by 57
Braverman, I. M., & Keh-Yen, A. (1984) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12260279 · Cited by 57
Klonoff, D. C. (2004) · Diabetes Care · doi:10.2337/diacare.27.3.834 · Cited by 56
Evans, N. D., Gnudi, L., Rolinski, O. J., Birch, D. J. S., & Pickup, J. C. (2003) · Diabetes Technology & Therapeutics · doi:10.1089/152091503322527012 · Cited by 43
Development of the Biostator Glucose clamping algorithm.
Clemens, A. H., Hough, D. L., & D'Orazio, P. A. (1982) · Clinical Chemistry · doi:10.1093/clinchem/28.9.1899 · Cited by 42
A Noninvasive Glucose Monitor: Preliminary Results in Rabbits
Borchert, M., Storrie‐Lombardi, M. C., & Lambert, J. L. (1999) · Diabetes Technology & Therapeutics · doi:10.1089/152091599317350 · Cited by 42
Influence of Epidermal Thickness, Pigmentation and Redness on Skin Autofluorescence¶
Sandby‐Møller, J., Poulsen, T., & Wulf, H. C. (2003) · Photochemistry and Photobiology · doi:10.1562/0031-8655(2003)0770616ioetpa2.0.co2 · Cited by 40
Shen, Y., Lu, Z., Spiers, S., MacKenzie, H. A., Ashton, H., Hannigan, J., Freeborn, S. S., & Lindberg, J. M. (2000) · Applied Optics · doi:10.1364/ao.39.004007 · Cited by 38
Heinemann, L., Krämer, U., Klötzer, H.-M., Hein, M., Volz, D., Hermann, M., Heise, T., & Rave, K. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/15209150050025168 · Cited by 34
Heise, H. M., & Marbach, R. (1998) · PubMed · Cited by 33
Oomen, P. H. N., Kant, G. D., Dullaart, R. P. F., Reitsma, W. D., & Smit, A. J. (2002) · Microvascular Research · doi:10.1006/mvre.2001.2347 · Cited by 33
Steffes, P. G. (1999) · Diabetes Technology & Therapeutics · doi:10.1089/152091599317332 · Cited by 33
Hyperglycemia-Induced Hyponatremia
Tzamaloukas, A. H. (1974) · New England Journal of Medicine · doi:10.1056/nejm197403072901020 · Cited by 31
Spectral Differences between Stratum Corneum and Sebaceous Molecular Components in the Mid-IR
Brancaleon, L., Bamberg, M. P., & Kollias, N. (2000) · Applied Spectroscopy · doi:10.1366/0003702001950742 · Cited by 31
Elishkevitz, K. P., Fusman, R., Koffler, M., Shapira, I., Zeltser, D., Avitzour, D., Arber, N., Berliner, S. A., & Rotstein, R. (2002) · Diabetic Medicine · doi:10.1046/j.1464-5491.2002.00674.x · Cited by 30
Defects in microvascular haemodynamics during prediabetes: contributor or epiphenomenon?
Wiernsperger, N. F. (2000) · Diabetologia · doi:10.1007/s001250051552 · Cited by 29
Cohen, O., Fine, I., Monashkin, E., & Karasik, A. (2003) · Diabetes Technology & Therapeutics · doi:10.1089/152091503763816418 · Cited by 25
Intraocular Lens Glucose Sensor
March, W. F., Ochsner, K. I., & Horna, J. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/152091500316700 · Cited by 24
Haak, E., Haak, T., Grözinger, Y., Krebs, G., Usadel, K. H., & Kusterer, K. (1998) · Journal of Vascular Research · doi:10.1159/000025590 · Cited by 23
Fusman, R., Rotstein, R., Elishkewich, K., Zeltser, D., Cohen, S., Kofler, K., Avitzour, D., Arber, N., Berliner, S. A., & Shapira, I. (2001) · Acta Diabetologica · doi:10.1007/s005920170009 · Cited by 22
Yeh, S.-J., Khalil, O. S., Hanna, C. F., & Kantor, S. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1578641 · Cited by 21
Self-citationHeise, H. M., & Lampen, P. (2000) · Diabetes Care · doi:10.2337/diacare.23.8.1208 · Cited by 17
POLARIMETRIC METHODS FOR MEASUREMENT OF INTRA OCULAR GLUCOSE CONCENTRATION
Rawer, R., Stork, W., & Müller-Glaser, K.-D. (2002) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.2002.47.s1a.186 · Cited by 17
Body Metabolism Provides a Foundation for Noninvasive Blood Glucose Monitoring
Ko, J. B., Cho, O. K., Kim, Y. O., & Yasuda, K. (2004) · Diabetes Care · doi:10.2337/diacare.27.5.1211 · Cited by 16
Regulatory Aspects of Noninvasive Glucose Measurements
Gutman, S., Bernhardt, P., Pinkos, A., Moxey‐Mims, M., Knott, T., & Cooper, J. (2002) · Diabetes Technology & Therapeutics · doi:10.1089/152091502321118793 · Cited by 10
Letter: Hyperglycemia-induced hyponatremia.
Jenkins, P., & Larmore, C. (1974) · PubMed · Cited by 10
Determination of blood flow in the finger using near‐infrared spectroscopy
Rendell, M., Hovelson, C., O'Connor, K., Cheung, L., Huard, S., Kong, T., Catania, A., & Rosenthal, R. (1998) · Clinical Physiology · doi:10.1046/j.1365-2281.1998.00108.x · Cited by 8
Cited by
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.161596 · Cited by 1,360
Villena Gonzales, W., Mobashsher, A., & Abbosh, A. (2019) · Sensors · doi:10.3390/s19040800 · Cited by 772
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Diabetes Care · doi:10.2337/dc11-9998 · Cited by 718
Non-invasive glucose monitoring technology in diabetes management: A review
Vashist, S. K. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.03.043 · Cited by 575
Correlation Between Sweat Glucose and Blood Glucose in Subjects with Diabetes
Moyer, J., Wilson, D., Finkelshtein, I., Wong, B., & Potts, R. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0262 · Cited by 570
Metadata
- Authors
- Khalil, O. S.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2004-10
- Volume
- 6
- Issue
- 5
- Pages
- 660-697
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2036030512
- Cited by
- 255
- References
- 108
- FWCI
- 8.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.