Clock networks for height system unification: a simulation study
The DOI matches its Crossref record; 37 of the 40 references it cites were found in a registry or an index, and 1 are not checked yet; 6 of the 17 sources its claims cite were checked for support.
Abstract
The unification of local height systems has been a classical geodetic problem for a long time, the main challenges of which are the estimation of offsets between different height systems and the correction of tilts along the levelling lines. It has been proposed to address these challenges with clock networks. The latest generation of optical clocks as well as the dedicated frequency links, for example optical fibres, are now approaching to deliver the comparison of frequencies at the level of 1.0 × 10−18. It corresponds to an accuracy of about 1.0 cm in height difference. Clock networks can thus serve as a powerful tool to connect local height systems. To verify the idea, we carried out simulations using the EUVN/2000 (European Unified Vertical Network) as apriori input. Four local height systems were simulated from the EUVN/2000 by introducing individual offsets and tilts, and were reunified by using measurements in clock networks. The results demonstrate the great potential of clock networks for height system unification. In case that the offsets between different height systems and tilts along national levelling lines in both longitudinal and latitudinal directions are considered, three or four clocks measurements for each local region are sufficient for the unification. These clocks are to be interconnected and should be properly arranged so that they can sense the levelling tilts where necessary. Our results also indicate that even clocks with one magnitude poorer accuracy than the desired ones can still unify the height systems to some extent, but it may cause a shift for the reunified system.
Verified 2026-11-22 · 1 reference not checked yet
Overview
CoChat Summary
TL;DR
This simulation study tests whether networks of high-performance optical clocks can unify local height systems by estimating vertical datum offsets and levelling tilts. Using EUVN/2000 as a priori truth, it finds that a few properly arranged clocks per region can reduce adjusted height errors to about 1 cm, but current clock accuracy may still limit full unification.
Key findings
- In the simulated reunification, adjusted height errors were reduced to roughly 1 cm across cases: CASE A (offsets only) RMS of adjusted errors 0.91–1.14 cm; CASE B (offsets plus latitudinal tilts) 0.95–1.24 cm; CASE C (offsets plus latitudinal and longitudinal tilts) 0.90–1.28 cm. True errors were much larger, e.g. in CASE C up to 62.35 cm RMS for one group.
- Clock number requirements depend on error type: one clock per region sufficed for offsets only (CASE A), one more clock was needed for latitudinal tilts (CASE B), and at least three clocks per region were required when offsets and tilts in both directions were considered (CASE C); four clocks improved performance, while five gave no evident further improvement.
- Spatial distribution matters: clocks arranged along the longitudinal direction failed to sense north–south tilts for height systems one and four, whereas diagonal or latitudinal arrangements performed well; if tilt direction is unknown, the paper recommends placing clocks along the (off-)diagonal direction.
- Clock accuracy affects results: at 1.0 × 10−18 relative frequency uncertainty, adjusted errors were about 1 cm; at 5.0 × 10−18 they were about 1.7 cm; at 20.0 × 10−18 unification was only partial, offsets were not exactly estimated, and the reunified system showed a positive shift of about 4.5 cm.
Methods
- A simulator used EUVN/2000 normal heights as the a priori unified system, dividing about 200 levelling points into four local height systems tied to tide gauges at Marseille, Newlyn, NAP and Genova; group sizes were 29, 16, 73 and 84 points (202 total).
- Random white noise of 1.0 cm was added to levelling heights, along with constant biases and tilts of 1–3 cm/100 km; clock-based measurements were simulated as potential differences from true height differences, with white noise at a desired relative frequency level of 1.0 × 10−18, and all clocks were assumed interconnected.
- Three cases were run: CASE A with biases only (−18.0, 25.0, 0.0, 8.0 cm); CASE B adding latitudinal tilts (3.0, −2.0, 1.5, −3.0 cm/100 km); CASE C adding longitudinal tilts (2.0, 3.0, −1.5, −2.0 cm/100 km). A least-squares joint adjustment estimated geopotential numbers and error parameters, and estimated reunified heights were compared with a priori true heights.
Limitations
- The paper states that it assumed ideal conditions: clocks with identical accuracies, independent and consistent clock measurements, and only random clock errors; real clocks may have biases, drifts, other instrument-related systematic errors, different precision and correlations, requiring a refined stochastic model.
- The paper states that systematic errors of national vertical networks may be unknown or more complicated than the assumed offsets and tilts; it suggests combining clock-based methods with GNSS/geoid approaches or subdividing the research region.
- The paper states that height offsets were assumed only up to 25 cm, whereas in practice they can reach 1–2 m, and that current clocks still lack accuracy for a highly accurate 1 cm unified system; it also notes that not all clocks may be linked in practice, an assumption made in the simulation.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
4 Valid · 0 Not valid · 9 Not checked · 49 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The latest generation of optical clocks as well as the dedicated frequency links, for example optical fibres, are now approaching to deliver the comparison of frequencies at the level of 1.0 × 10−18.”
What the sources say
- Partly supportedcites Bloom et al. 2014 matched to “An optical lattice clock with accuracy and stability at the 10−18 level” (2014) sourceExperimental — accuracy not yet measured
The Introduction (p. 2) reports an optical clock uncertainty of 6.4 × 10−18, and the Conclusions (p. 9) say the demonstrated techniques have no foreseeable limitation to reaching below 1 × 10−18. The Introduction also discusses advances in frequency distribution, with a fibre-link study listed in the References (p. 10). But the paper does not establish a clock comparison over a dedicated link at 1 × 10−18; its reported comparison of two clocks had a combined uncertainty of 5.4 × 10−17 (Frequency Comparison, p. 3). (LLM, conf=0.82)
- Partly supportedcites Huntemann et al. 2016 matched to “Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty” (2016) sourceExperimental — accuracy not yet measured
The opening summary (p. 1) reports a total systematic uncertainty of 3.2 × 10−18 for a single-ion optical clock, supporting the claim that optical clocks are approaching the 10−18 level. The 1.1 × 10−18 figure on pp. 1–2 applies only to one source of clock uncertainty. The paper does not establish frequency comparisons at 1.0 × 10−18 or address dedicated optical-fibre links. (LLM, conf=0.85)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“In case that the offsets between different height systems and tilts along national levelling lines in both longitudinal and latitudinal directions are considered, three or four clocks measurements for each local region are sufficient for the unification.”
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on an assumption not shown here.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“When three clocks are used, the adjusted errors are significantly reduced to the level of the other two groups, see Figs 9(b) and 10(b).”
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The true errors for CASE B and C are slightly more complicated than those of CASE A (they show significant differences to the offsets), due to the influence of tilts.”
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“A further improvement was not evident when the number of clocks was increased to five.”
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
30 more claims
Create a free account to see all 62 claims and every source verdict.
- Probably not a substantial claim. 10
- It may state two separate claims as one. 19
- The quote only partly states this claim. 3
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“According to their simulation results, the height systems of the West European region can be unified at a precision of better than 1 cm, under the assumption that the clock frequency uncertainty is 1 × 10 -18 .”
From Unification of a Global Height System at the Centimeter-Level Using Precise Clock Frequency Signal Links (2023) · cites this paper as [31]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In summary, the existing methods cannot achieve the unification of global height datum with an accuracy of 1 cm, which is of great significance to develop new methods to solve this problem.”
From Performance Evaluation and Requirement Analysis for Chronometric Leveling with High-Accuracy Optical Clocks (2022) · cites this paper as [8]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
In the paper
§ 29 16 73 84 202
“The place- ment of clocks in the longitudinal direction can sense the north– south tilt, and the placement in the latitudinal direction can sense the east–west tilt.”
§ 29 16 73 84 202
“if clocks are arranged in the longitudinal direction, they will not be sensible to the tilts along the north–south direction.”
Citations
Cites
Parameter Estimation and Hypothesis Testing in Linear Models
Koch, K.-R. (1999) · Springer eBooks · doi:10.1007/978-3-662-03976-2 · Cited by 1,309
An optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
Chou, C. W., Hume, D. B., Rosenband, T., & Wineland, D. J. (2010) · Science · doi:10.1126/science.1192720 · Cited by 828
Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677
Geodesy and metrology with a transportable optical clock
Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., et al. (2018) · Nature Physics · doi:10.1038/s41567-017-0042-3 · Cited by 495
A clock network for geodesy and fundamental science
Lisdat, C., Grosche, G., Quintin, N., Shi, C., Raupach, S. M. F., Grebing, C., Nicolodi, D., Stefani, F., Al-Masoudi, A., Dörscher, S., et al. (2016) · Nature Communications · doi:10.1038/ncomms12443 · Cited by 460
Parameter Estimation and Hypothesis Testing in Linear Models
Koch, K.-R. (1988) · Springer eBooks · doi:10.1007/978-3-662-02544-4 · Cited by 314
Riehle, F. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.235 · Cited by 264
Geopotential measurements with synchronously linked optical lattice clocks
Takano, T., Takamoto, M., Ushijima, I., Ohmae, N., Akatsuka, T., Yamaguchi, A., Kuroishi, Y., Munekane, H., Miyahara, B., & Katori, H. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.159 · Cited by 245
Transportable Optical Lattice Clock with 7 × 10 − 17 Uncertainty
Koller, S. B., Grotti, J., Vogt, S., Al-Masoudi, A., Dörscher, S., Häfner, S., Sterr, U., & Lisdat, C. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.073601 · Cited by 238
Torge, W., & Müller, J. (2012) · doi:10.1515/9783110250008 · Cited by 220
Self-citationFirst accuracy evaluation of NIST-F2
Heavner, T. P., Donley, E. A., Levi, F., Costanzo, G., Parker, T. E., Shirley, J. H., Ashby, N., Barlow, S., & Jefferts, S. R. (2014) · Metrologia · doi:10.1088/0026-1394/51/3/174 · Cited by 205
Drewes, H., Kuglitsch, F., Adám, J., & Rózsa, S. (2016) · Journal of Geodesy · doi:10.1007/s00190-016-0948-z · Cited by 174
Bjerhammar, A. (1985) · Bulletin Géodésique · doi:10.1007/bf02520327 · Cited by 165
Height datum definition, height datum connection and the role of the geodetic boundary value problem
Rummel, R., & Teunissen, P. J. G. (1988) · Journal of Geodesy · doi:10.1007/bf02520239 · Cited by 152
Definition and Proposed Realization of the International Height Reference System (IHRS)
Ihde, J., Sánchez, L., Barzaghi, R., Drewes, H., Foerste, C., Gruber, T., Liebsch, G., Marti, U., Pail, R., & Sideris, M. (2017) · Surveys in Geophysics · doi:10.1007/s10712-017-9409-3 · Cited by 113
Vertical datum unification for the International Height Reference System (IHRS)
Sánchez, L., & Sideris, M. G. (2017) · Geophysical Journal International · doi:10.1093/gji/ggx025 · Cited by 106
Denker, H., Timmen, L., Voigt, C., Weyers, S., Peik, E., Margolis, H. S., Delva, P., Wolf, P., & Petit, G. (2018) · Journal of Geodesy · doi:10.1007/s00190-017-1075-1 · Cited by 91
Towards worldwide height system unification using ocean information
Woodworth, P. L., Hughes, C. W., Bingham, R. J., & Gruber, T. (2012) · Journal of Geodetic Science · doi:10.2478/v10156-012-0004-8 · Cited by 91
High Performance Clocks and Gravity Field Determination
Müller, J., Dirkx, D., Kopeikin, S. M., Lion, G., Panet, I., Petit, G., & Visser, P. N. A. M. (2018) · Space Science Reviews · doi:10.1007/s11214-017-0431-z · Cited by 81
Self-citationDetermination of a high spatial resolution geopotential model using atomic clock comparisons
Lion, G., Panet, I., Wolf, P., Guerlin, C., Bize, S., & Delva, P. (2017) · Journal of Geodesy · doi:10.1007/s00190-016-0986-6 · Cited by 66
The relativistic redshift with 3 10 17uncertainty at NIST, Boulder, Colorado, USA
Pavlis, N. K., & Weiss, M. A. (2003) · Metrologia · doi:10.1088/0026-1394/40/2/311 · Cited by 57
Intercontinental height datum connection with GOCE and GPS-levelling data
Gruber, T., Gerlach, C., & Haagmans, R. (2012) · Journal of Geodetic Science · doi:10.2478/v10156-012-0001-y · Cited by 55
Gerlach, C., & Rummel, R. (2013) · Journal of Geodesy · doi:10.1007/s00190-012-0579-y · Cited by 54
Voigt, C., Denker, H., & Timmen, L. (2016) · Metrologia · doi:10.1088/0026-1394/53/6/1365 · Cited by 50
Towards a vertical datum standardisation under the umbrella of Global Geodetic Observing System
Sánchez, L. (2012) · Journal of Geodetic Science · doi:10.2478/v10156-012-0002-x · Cited by 49
Freeden, W., Nashed, M. Z., & Sonar, T. (2014) · Springer eBooks · doi:10.1007/978-3-642-27793-1 · Cited by 47
Colombo, O. L. (1980) · doi:10.21236/ada086011 · Cited by 42
Unification of European height system realizations
Rülke, A., Liebsch, G., Sacher, M., Schäfer, U., Schirmer, U., & Ihde, J. (2012) · Journal of Geodetic Science · doi:10.2478/v10156-011-0048-1 · Cited by 40
Atomic clocks: new prospects in metrology and geodesy
Delva, P., & Lodewyck, J. (2013) · arXiv · doi:10.48550/arxiv.1308.6766 · Cited by 40
Global Unification of Height Systems and GOCE
Rummel, R. (2001) · International Association of Geodesy Symposia · doi:10.1007/978-3-662-04827-6_3 · Cited by 35
The GBVP approach for vertical datum unification: Recent results in North America
Amjadiparvar, B., Rangelova, E., & Sideris, M. G. (2016) · Journal of Geodesy · doi:10.1007/s00190-015-0855-8 · Cited by 30
Space-time reference with an optical link
Berceau, P., Taylor, M., Kahn, J. M., & Hollberg, L. W. (2016) · Classical and Quantum Gravity · doi:10.1088/0264-9381/33/13/135007 · Cited by 30
A re-evaluation of the relativistic redshift on frequency standards at NIST, Boulder, Colorado, USA
Pavlis, N. K., & Weiss, M. A. (2017) · Metrologia · doi:10.1088/1681-7575/aa765c · Cited by 19
Definition of the relativistic geoid in terms of isochronometric surfaces
Philipp, D., Perlick, V., Puetzfeld, D., Hackmann, E., & Lämmerzahl, C. (2017) · Physical review. D/Physical review. D. · doi:10.1103/physrevd.95.104037 · Cited by 17
Self-citationGeodetic world height system unification
Sideris, M. (2014) · Handbook of Geomathematics · doi:10.1007/978-3-642-27793-1_83-1 · Cited by 7
High Performance Clocks and Gravity Field Determination
Müller, J., Dirkx, D., Kopeikin, S. M., Lion, G., Panet, I., Petit, G., & Visser, P. N. A. M. (2017) · Space sciences series of ISSI · doi:10.1007/978-94-024-1566-7_4 · Cited by 1
Self-citationTowards worldwide height unification using ocean information
Woodworth, P., & Hughes, C. (2011) · doi:10.5194/piahs-365-11-2015 · Cited by 1
Research works printed but not linked: 1
- Ihde, J., Adam, J., Gurtner, W., Harsson, B., Sacher, M., Schlüter, W. & Wöppelmann, G., 2000. The height solution of the European Vertical Ref- erence Network (EUVN), Veröff. Bayer. Komm. für die Internat. Erdmes- sung, Astronom. Geod. Arb, 61, 132–145.
Cited by
Cold atoms in space: community workshop summary and proposed road-map
Alonso, I., Alpigiani, C., Altschul, B., Araújo, H. M., Arduini, G., Arlt, J., Badurina, L., Balaž, A., Bandarupally, S., Barish, B. C., et al. (2022) · EPJ Quantum Technology · doi:10.1140/epjqt/s40507-022-00147-w · Cited by 61
Using quantum optical sensors for determining the Earth’s gravity field from space
Müller, J., & Wu, H. (2020) · Journal of Geodesy · doi:10.1007/s00190-020-01401-8 · Cited by 32
Self-citationTowards an International Height Reference Frame Using Clock Networks
Wu, H., & Müller, J. (2020) · International Association of Geodesy symposia · doi:10.1007/1345_2020_97 · Cited by 20
Self-citationA Decade of Advancement of Quantum Sensing and Metrology in India Using Cold Atoms and Ions
Dutta, P., Maurya, S. S., Patel, K., Biswas, K., Mangaonkar, J., Sarkar, S., & Rapol, U. D. (2022) · Journal of the Indian Institute of Science · doi:10.1007/s41745-022-00335-8 · Cited by 11
Sanchez, L. A., Barzaghi, R., & Vergos, G. S. (2024) · International Association of Geodesy symposia · doi:10.1007/1345_2024_250 · Cited by 12
Metadata
- Authors
- Wu, H., Müller, J., & Lämmerzahl, C.
- Affiliations
- Leibniz University Hannover (DE)
- Zentrum für Angewandte Raumfahrttechnologie und Mikrogravitation (ZARM), Universität Bremen, Am Fallturm 2, 28359 Bremen, Germany
- Corresponding author
- Wu, Hu
- ORCID
- Venue
- Geophysical Journal International
- Publisher
- Oxford University Press (OUP)
- Published
- 2018-11-28
- Volume
- 216
- Issue
- 3
- Pages
- 1594-1607
- ISSN
- 0956-540X (ISSN-L)
- 1365-246X
- OpenAlex
- W2903131677
- Semantic Scholar
- a21bad0ee60140702dd3a0726f71c4c71bac9214
- Cited by
- 30
- References
- 40
- Citations by year
- 2026: 4 · 2025: 4 · 2024: 8 · 2023: 5 · 2022: 5 · 2021: 1 · 2020: 3
- FWCI
- 0.46
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- academic.oup.com/journals/pages/open_access/funder_policies/chorus/standard_publication_model (vor)
- Locations
- Geophysical Journal International (publishedVersion)
- Funders
- DFG
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Engineering › Aerospace Engineering › GNSS positioning and interference
- Physical Sciences › Engineering › Civil and Structural Engineering › Geodetic Measurements and Engineering Structures
- Keywords
- clock distribution, frequency comparison, leveling network, simulation study
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-11, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-11 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.