Simultaneous Blood Oxygenation Level-Dependent and Cerebral Blood Flow Functional Magnetic Resonance Imaging during Forepaw Stimulation in the Rat
Open accessThe DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Abstract
The blood oxygenation level-dependent (BOLD) contrast mechanism can be modeled as a complex interplay between CBF, cerebral blood volume (CBV), and CMRO 2. Positive BOLD signal changes are presumably caused by CBF changes in excess of increases in CMRO 2. Because this uncoupling between CBF and CMRO 2 may not always be present, the magnitude of BOLD changes may not be a good index of CBF changes. In this study, the relation between BOLD and CBF was investigated further. Continuous arterial spin labeling was combined with a single-shot, multislice echo-planar imaging to enable simultaneous measurements of BOLD and CBF changes in a well-established model of functional brain activation, the electrical forepaw stimulation of a-chloralose-anesthetized rats. The paradigm consisted of two 18- to 30-second stimulation periods separated by a 1-minute resting interval. Stimulation parameters were optimized by laser Doppler flowmetry. For the same cross-correlation threshold, the BOLD and CBF active maps were centered within the size of one pixel (470 µm). However, the BOLD map was significantly larger than the CBF map. Measurements taken from 15 rats at 9.4 T using a 10-millisecond echo-time showed 3.7 ± 1.7% BOLD and 125.67 ± 81.7% CBF increases in the contralateral somatosensory cortex during the first stimulation, and 2.6 ± 1.2% BOLD and 79.3 ± 43.6% CBF increases during the second stimulation. The correlation coefficient between BOLD and CBF changes was 0.89. The overall temporal correlation coefficient between BOLD and CBF time-courses was 0.97. These results show that under the experimental conditions of the current study, the BOLD signal changes follow the changes in CBF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Rat Brain in Stereotaxic Coordinates
(1982) · Elsevier eBooks · doi:10.1016/c2009-0-63235-9 · Cited by 51,963 · cited 1×
“The locations of the centers of the BOLD and the CBF maps are in excellent agreement with the coordinates of the forelimb area of the somatosensory cortex (Paxinos and Watson, 1996; Schmitz et aI., 1996).”
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Ogawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681
Self-citationForman, S. D., Cohen, J. D., Fitzgerald, M., Eddy, W. F., Mintun, M. A., & Noll, D. C. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330508 · Cited by 3,202
Oxygenation‐sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields
Ogawa, S., Lee, T., Nayak, A. S., & Glynn, P. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140108 · Cited by 2,266
Fox, P. T., & Raichle, M. E. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.4.1140 · Cited by 2,056 · cited 1×
“However, the relation between these variables is not fully understood, Positive BOLD signal changes are presumably caused by fractional in creases in CBF that are unmatched by fractional in creases in CMR02 (Fox and Raichle, 1986; Ogawa et al., 1993a).”
BackgroundTime course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935
Ogawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81441-3 · Cited by 1,772
Self-citationProcessing strategies for time‐course data sets in functional mri of the human brain
Bandettini, P. A., Jesmanowicz, A., Wong, E. C., & Hyde, J. S. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300204 · Cited by 1,763
Detre, J. A., Leigh, J. S., Williams, D. S., & Koretsky, A. P. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910230106 · Cited by 1,571
Magnetic resonance imaging of perfusion using spin inversion of arterial water.
Williams, D. S., Detre, J. A., Leigh, J. S., & Koretsky, A. P. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.1.212 · Cited by 1,546
Thulborn, K. R., Waterton, J. C., Matthews, P. M., & Radda, G. K. (1982) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(82)90333-6 · Cited by 1,134
Kim, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340303 · Cited by 1,001 · cited 1×
“Endogenous arterial water can be used as a MRI contrast agent to quantify absolute blood flow (Williams et aI., 1992; Detre et aI., 1992; Kwong et aI., 1992; Detre et aI., 1994; Edelman et aI., 1994; Silva et aI., 1995; Kwong et aI., 1995; Kim, 1995).”
BackgroundSelf-citationWhat is the Correct Value for the Brain-Blood Partition Coefficient for Water?
Herscovitch, P., & Raichle, M. E. (1985) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1985.9 · Cited by 705
Edelman, R. R., Siewert, B., Darby, D. G., Thangaraj, V, Nobre, A. C., Mesulam, M. M., & Warach, S. (1994) · Radiology · doi:10.1148/radiology.192.2.8029425 · Cited by 700
Ogawa, S., & Lee, T. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160103 · Cited by 565
Mr perfusion studies with t1‐weighted echo planar imaging
Kwong, K. K., Chesler, D. A., Weisskoff, R. M., Donahue, K. M., Davis, T. L., Ostergaard, L., Campbell, T. A., & Rosen, B. R. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340613 · Cited by 477
Echo‐planar time course MRI of cat brain oxygenation changes
Turner, R., Bihan, D. L., Moonen, C. T. W., Despres, D., & Frank, J. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910220117 · Cited by 421
Menon, R. S., Ogawa, S., Tank, D. W., & Uǧurbil, K. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300317 · Cited by 413
Lai, S., Hopkins, A. L., Haacke, E. M., Li, D., Wasserman, B. A., Buckley, P., Friedman, L., Meltzer, H., Hedera, P., & Friedland, R. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300318 · Cited by 390
Clustered pixels analysis for functional MRI activation studies of the human brain
Xiong, J., Gao, J., Lancaster, J. L., & Fox, P. T. (1995) · Human Brain Mapping · doi:10.1002/hbm.460030404 · Cited by 361
Brain or veinoxygenation or flow? On signal physiology in functional MRI of human brain activation
Frahm, J., Merboldt, K., Hänicke, W., Kleinschmidt, A., & Boecker, H. (1994) · NMR in Biomedicine · doi:10.1002/nbm.1940070108 · Cited by 342
Tissue specific perfusion imaging using arterial spin labeling
Detre, J. A., Zhang, W., Roberts, D. A., Silva, A. C., Williams, D. S., Grandis, D. J., Koretsky, A. P., & Leigh, J. S. (1994) · NMR in Biomedicine · doi:10.1002/nbm.1940070112 · Cited by 335
Self-citationFrahm, J., Krüger, G., Merboldt, K., & Kleinschmidt, A. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350202 · Cited by 327
Does mental activity change the oxidative metabolism of the brain?
Roland, P. E., Eriksson, L., Stone‐Elander, S., & Widén, L. (1987) · Europe PMC (PubMed Central) · Cited by 310
Ogawa, S., Lee, T. M., & Barrere, B. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290208 · Cited by 281
Does nitric oxide mediate the increases in cerebral blood flow elicited by hypercapnia?
Iadecola, C. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.9.3913 · Cited by 255
Self-citationKim, S., & Tsekos, N. V. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370321 · Cited by 247
Self-citationPotential pitfalls of functional MRI using conventional gradient‐recalled echo techniques
Kim, S., Hendrich, K., Hu, X., Merkle, H., & Uǧurbil, K. (1994) · NMR in Biomedicine · doi:10.1002/nbm.1940070111 · Cited by 224
Self-citationKim Cmrr, S., & Uĝurbil, K. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380110 · Cited by 220
Ueki, M., Linn, F., & Hossmann, K.-A. (1988) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1988.89 · Cited by 215
Diffusion weighted fMRI at 1.5 T
Song, A. W., Wong, E. C., Tan, S. G., & Hyde, J. S. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350204 · Cited by 208
Seitz, R. J., & Roland, P. E. (1992) · Acta Neurologica Scandinavica · doi:10.1111/j.1600-0404.1992.tb08055.x · Cited by 205 · cited 1×
“This mismatch between CBF and CMR02 changes may not be present in all activated regions at all times (Roland et aI., 1987; Seitz and Roland, 1992; Frahm et aI., 1996; Kruger et aI., 1996).”
BackgroundUeki, M., Mies, G., & Hossmann, K. ‐. (1992) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.1992.tb03474.x · Cited by 203
Hyder, F., Chase, J. R., Behar, K. L., Mason, G. F., Siddeek, M., Rothman, D. L., & Shulman, R. G. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.15.7612 · Cited by 188
NMR Measurement of Perfusion Using Arterial Spin Labeling Without Saturation of Macromolecular Spins
Zhang, W., Silva, A. C., Williams, D. S., & Koretsky, A. P. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330310 · Cited by 158
Self-citationMulti‐Slice MRI of Rat Brain Perfusion During Amphetamine Stimulation Using Arterial Spin Labeling
Silva, A. C., Zhang, W., Williams, D. S., & Koretsky, A. P. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330210 · Cited by 156
Self-citationDynamic Magnetic Resonance Imaging of the Rat Brain during Forepaw Stimulation
Hyder, F., Behar, K. L., Martin, M. A., Blamire, A. M., & Shulman, R. G. (1994) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1994.81 · Cited by 156
Hyder, F., Rothman, D. L., Mason, G. F., Rangarajan, A., Behar, K. L., & Shulman, R. G. (1997) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199710000-00005 · Cited by 124
Gyngell, M. L., Bock, C., Schmitz, B., Hoehn‐Berlage, M., & Hossmann, K. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360104 · Cited by 110
Silva, A. C., Zhang, W., Williams, D. S., Koretsky, A. P., & Koretsky, A. P. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370110 · Cited by 109
Self-citationTsekos, N. V., Zhang, F., Merkle, H., Nagayama, M., ladecola, C., & Kim, S. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390409 · Cited by 105
Self-citationKim, S.-G., Tsekos, N. V., & Ashe, J. (1997) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199706/08)10:4/5<191::aid-nbm460>3.0.co;2-r · Cited by 99
Self-citationKrüger, G., Kleinschmidt, A., & Frahm, J. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350602 · Cited by 94
Functional Increases in Cerebral Blood Volume over Somatosensory Cortex
Narayan, S. M., Esfahani, P., Blood, A. J., Sikkens, L., & Toga, A. W. (1995) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1995.95 · Cited by 83
Kerskens, C. M., Hoehn-Berlage, M., Schmitz, B., Busch, E., Bock, C., Gyngell, M. L., & Hossmann, K.-A. (1996) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199602)9:1<20::aid-nbm381>3.0.co;2-r · Cited by 79
Mapping of lateral geniculate nucleus activation during visual stimulation in human brain using fMRI
Chen, W., Kato, T., Zhu, X., Strupp, J., Ogawa, S., & Uǧurbil, K. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390115 · Cited by 76
Detre, J. A., Ances, B. M., Takahashi, K., & Greenberg, J. H. (1998) · Brain Research · doi:10.1016/s0006-8993(98)00322-9 · Cited by 71
Nitric oxide participates in the cerebrovasodilation elicited from cerebellar fastigial nucleus
Iadecola, C. (1992) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1992.263.5.r1156 · Cited by 60
Self-citationFunctional MRI of the rat somatosensory cortex: Effects of hyperventilation
Hsu, E. W., Hedlund, L. W., & MacFall, J. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400312 · Cited by 38
Cited by
Local potassium signaling couples neuronal activity to vasodilation in the brain
Filosa, J. A., Bonev, A. D., Straub, S. V., Meredith, A. L., Wilkerson, M. K., Aldrich, R. W., & Nelson, M. T. (2006) · Nature Neuroscience · doi:10.1038/nn1779 · Cited by 563
Study design in fMRI: Basic principles
Amaro, E., & Barker, G. J. (2006) · Brain and Cognition · doi:10.1016/j.bandc.2005.11.009 · Cited by 517
Imaging brain function in humans at 7 Tesla
Yacoub, E., Shmuel, A., Pfeuffer, J., Van De Moortele, P., Adriany, G., Andersen, P., Vaughan, J. T., Merkle, H., Ugurbil, K., & Hu, X. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1080 · Cited by 448
Methodology of brain perfusion imaging
Barbier, E. L., Lamalle, L., & Décorps, M. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1073 · Cited by 404
Technical aspects and utility of fMRI using BOLD and ASL
Detre, J. A., & Wang, J. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00038-x · Cited by 291
“Functional signal changes detected by ASL may also have superior spatial and temporal resolution as compared to BOLD contrast (Silva et al., 1999; Duong et al., 2001).”
BackgroundInfluential
Metadata
- Authors
- Silva, A. C., Lee, S.-P., Yang, G., Iadecola, C., & Kim, S.-G.
- Venue
- Journal of Cerebral Blood Flow & Metabolism
- Publisher
- SAGE Publications
- Published
- 1999-08
- Volume
- 19
- Issue
- 8
- Pages
- 871-879
- ISSN
- 0271-678X (ISSN-L)
- 1559-7016
- OpenAlex
- W1966327514
- Cited by
- 233
- References
- 51
- FWCI
- 12.15
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.