The DOI matches its Crossref record.
A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity
Open accessAbstract
The present study describes the development of a triaxial accelerometer (TA) and a portable data processing unit for the assessment of daily physical activity. The TA is composed of three orthogonally mounted uniaxial piezoresistive accelerometers and can be used to register accelerations covering the amplitude and frequency ranges of human body acceleration. Interinstrument and test-retest experiments showed that the offset and the sensitivity of the TA were equal for each measurement direction and remained constant on two measurement days. Transverse sensitivity was significantly different for each measurement direction, but did not influence accelerometer output (< 3% of the sensitivity along the main axis). The data unit enables the on-line processing of accelerometer output to a reliable estimator of physical activity over eight-day periods. Preliminary evaluation of the system in 13 male subjects during standardized activities in the laboratory demonstrated a significant relationship between accelerometer output and energy expenditure due to physical activity, the standard reference for physical activity (r = 0.89). Shortcomings of the system are its low sensitivity to sedentary activities and the inability to register static exercise. The validity of the system for the assessment of normal daily physical activity and specific activities outside the laboratory should be studied in free-living subjects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Activity Recognition from User-Annotated Acceleration Data
Bao, L., & Intille, S. S. (2004) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-24646-6_1 · Cited by 3,147
A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring
Yang, C.-C., & Hsu, Y.-L. (2010) · Sensors · doi:10.3390/s100807772 · Cited by 1,058
Human motion tracking for rehabilitation-A survey
Zhou, H., & Hu, H. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.09.001 · Cited by 813
Physical Activity Assessment With Accelerometers: An Evaluation Against Doubly Labeled Water
Plasqui, G., & Westerterp, K. R. (2007) · Obesity · doi:10.1038/oby.2007.281 · Cited by 654
Measuring orientation of human body segments using miniature gyroscopes and accelerometers
Luinge, H. J., & Veltink, P. H. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345966 · Cited by 647
Validation of the GENEA Accelerometer
ESLIGER, D. W., ROWLANDS, A. V., HURST, T. L., CATT, M., MURRAY, P., & ESTON, R. G. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31820513be · Cited by 625
Direct measurement of human movement by accelerometry
Godfrey, A., Conway, R., Meagher, D., & ÓLaighin, G. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.09.005 · Cited by 591
Preprocessing techniques for context recognition from accelerometer data
Figo, D., Diniz, P. C., Ferreira, D. R., & Cardoso, J. M. P. (2010) · Personal and Ubiquitous Computing · doi:10.1007/s00779-010-0293-9 · Cited by 578
Hurling, R., Catt, M., De Boni, M., Fairley, B. W., Hurst, T., Murray, P., Richardson, A., & Sodhi, J. S. (2007) · Journal of Medical Internet Research · doi:10.2196/jmir.9.2.e7 · Cited by 536
Preece, S. J., Goulermas, J. Y., Kenney, L. P. J., & Howard, D. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2006190 · Cited by 551
Activity Recognition of Assembly Tasks Using Body-Worn Microphones and Accelerometers
Ward, J. A., Lukowicz, P., Troster, G., & Starner, T. E. (2006) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2006.197 · Cited by 431
Dowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
Sensor Positioning for Activity Recognition Using Wearable Accelerometers
Atallah, L., Lo, B., King, R., & Yang, G.-Z. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2160540 · Cited by 346
Clinical Applications of Sensors for Human Posture and Movement Analysis: A Review
Wong, W. Y., Wong, M. S., & Lo, K. H. (2007) · Prosthetics & Orthotics International · doi:10.1080/03093640600983949 · Cited by 193
Dejnabadi, H., Jolles, B. M., Casanova, E., Fua, P., & Aminian, K. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.873678 · Cited by 189
Generating ActiGraph counts from raw acceleration recorded by an alternative monitor.
BRØND, J. C., ANDERSEN, L. B., & ARVIDSSON, D. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001344 · Cited by 166
Mobile Human Airbag System for Fall Protection Using MEMS Sensors and Embedded SVM Classifier
Shi, G., Chan, C. S., Li, W. J., Leung, K.-S., Zou, Y., & Jin, Y. (2009) · IEEE Sensors Journal · doi:10.1109/jsen.2008.2012212 · Cited by 162
A pilot study of long-term monitoring of human movements in the home using accelerometry
Mathie, M. J., Coster, A. C. F., Lovell, N. H., Celler, B. G., Lord, S. R., & Tiedemann, A. (2004) · Journal of Telemedicine and Telecare · doi:10.1258/135763304323070788 · Cited by 153
Nijsen, T. M. E., Arends, J. B. A. M., Griep, P. A. M., & Cluitmans, P. J. M. (2005) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2005.04.011 · Cited by 139
Gait analysis using gravitational acceleration measured by wearable sensors
Takeda, R., Tadano, S., Todoh, M., Morikawa, M., Nakayasu, M., & Yoshinari, S. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.10.027 · Cited by 128
Chamroukhi, F., Mohammed, S., Trabelsi, D., Oukhellou, L., & Amirat, Y. (2013) · Neurocomputing · doi:10.1016/j.neucom.2013.04.003 · Cited by 88
Drift Removal for Improving the Accuracy of Gait Parameters Using Wearable Sensor Systems
Takeda, R., Lisco, G., Fujisawa, T., Gastaldi, L., Tohyama, H., & Tadano, S. (2014) · Sensors · doi:10.3390/s141223230 · Cited by 84
Human activity recognition based on a sensor weighting hierarchical classifier
Banos, O., Damas, M., Pomares, H., Rojas, F., Delgado-Marquez, B., & Valenzuela, O. (2013) · Soft Computing · doi:10.1007/s00500-012-0896-3 · Cited by 79
Real-time elderly activity monitoring system based on a tri-axial accelerometer
Kang, D. W., Choi, J. S., Lee, J. W., Chung, S. C., Park, S. J., & Tack, G. R. (2010) · Disability and Rehabilitation: Assistive Technology · doi:10.3109/17483101003718112 · Cited by 43
Cardiorespiratory fitness estimation in free-living using wearable sensors
Altini, M., Casale, P., Penders, J., & Amft, O. (2016) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2016.02.002 · Cited by 34
Impact of Wearable Measurement Properties and Data Quality on ADLs Classification Accuracy
Poli, A., Cosoli, G., Scalise, L., & Spinsante, S. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3009368 · Cited by 33
Le Heron, C., Fang, K., Gubbi, J., Churilov, L., Palaniswami, M., Davis, S., & Yan, B. (2014) · Cerebrovascular Diseases · doi:10.1159/000360808 · Cited by 15
Manohar, C. U., Koepp, G. A., McCrady-Spitzer, S. K., & Levine, J. A. (2012) · ICAN: Infant, Child, & Adolescent Nutrition · doi:10.1177/1941406412450644 · Cited by 12
Nonparametric discovery of movement patterns from accelerometer signals
Nguyen, T., Gupta, S., Venkatesh, S., & Phung, D. (2016) · Pattern Recognition Letters · doi:10.1016/j.patrec.2015.11.003 · Cited by 8
Real-Time Quality Index to Control Data Loss in Real-Life Cardiac Monitoring Applications
Vila, G., Godin, C., Charbonnier, S., & Campagne, A. (2021) · Sensors · doi:10.3390/s21165357 · Cited by 8
Designing Compact Features for Remote Stroke Rehabilitation Monitoring using Wearable Accelerometers
Chen, X., Guan, Y., Shi, J. Q., Du, X.-L., & Eyre, J. (2020) · arXiv · doi:10.48550/arxiv.2009.08798 · Cited by 8
Metadata
- Authors
- Bouten, C. V. C., Koekkoek, K. T. M., Verduin, M., Kodde, R., & Janssen, J. D.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1997-03
- Volume
- 44
- Issue
- 3
- Pages
- 136-147
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2118630306
- Cited by
- 911
- References
- 0
- FWCI
- 1.91
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.