Perspectives on new electrode technology for stimulating peripheral nerves with implantable motor prostheses
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
The limits of present electrode technology are being reached in current motor prostheses for restoring functional movement in paralyzed people. Improved devices require electrodes and stimulation methods that will activate muscles selectively and independently with less implanted hardware. A practical functional neuromuscular stimulation (FNS) system may need to employ extraneural, intraneural, epimysial, or intramuscular electrodes or a combination of these types. The limitations of current muscle electrodes and the anatomy of peripheral nerve innervation of muscle have pointed to stimulation of peripheral nerve trunks as a promising area for investigation. Attempts to use conventional (extraneural) peripheral nerve electrodes for selective activation of muscles in chronic applications have met with only limited success. Intraneural (intrafascicular) electrodes offer the advantages of greater selectivity and lower power requirements, but these may be offset by the difficulty of inserting delicate electrodes through the collagenous epineurium and perineurium while avoiding unacceptable amounts of trauma. Cuff electrodes require more power than intrafascicular ones but may provide more stable recruitment patterns over time, and the opportunity for retrieval and replacement.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A spiral nerve cuff electrode for peripheral nerve stimulation
Naples, G. G., Mortimer, J. T., Scheiner, A., & Sweeney, J. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8670 · Cited by 415
Selective control of muscle activation with a multipolar nerve cuff electrode
Veraart, C., Grill, W. M., & Mortimer, J. T. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.237694 · Cited by 320
Sacral anterior root stimulators for bladder control in paraplegia: the first 50 cases
Brindley, G. S., Polkey, C. E., Rushton, D. N., & Cardozo, L. (1986) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.49.10.1104 · Cited by 313
Selective stimulation of peripheral nerve fibers using dual intrafascicular electrodes
Yoshida, K., & Horch, K. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.243412 · Cited by 208
Self-citationA nerve cuff technique for selective excitation of peripheral nerve trunk regions
Sweeney, J. D., Ksienski, D. A., & Mortimer, J. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55681 · Cited by 196
Agnew, W. F., McCreery, D. B., Yuen, T. G. H., & Bullara, L. A. (1989) · Annals of Biomedical Engineering · doi:10.1007/bf02364272 · Cited by 185
Self-citationChronically implanted intrafascicular recording electrodes
Lefurge, T., Goodall, E., Horch, K., Stensaas, L., & Schoenberg, A. (1991) · Annals of Biomedical Engineering · doi:10.1007/bf02368469 · Cited by 172
Self-citationWaters, R. L., McNeal, D. R., Faloon, W., & Clifford, B. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567050-00016 · Cited by 156
An intrafascicular electrode for recording of action potentials in peripheral nerves
Malagodi, M. S., Horch, K. W., & Schoenberg, A. A. (1989) · Annals of Biomedical Engineering · doi:10.1007/bf02368058 · Cited by 107
Self-citationMcCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. A. (1992) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446202 · Cited by 97
Self-citationA modeling study of nerve fascicle stimulation
Veltink, P. H., van Veen, B. K., Struijk, J. J., Holsheimer, J., & Boom, H. B. K. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.32100 · Cited by 95
Muscle recruitment with intrafascicular electrodes
Nannini, N., & Horch, K. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83589 · Cited by 94
Self-citationYoshida, K., & Horch, K. (1993) · Annals of Biomedical Engineering · doi:10.1007/bf02368649 · Cited by 69
Self-citationBowman, B. R., & Erickson, R. C. (1985) · Annals of Biomedical Engineering · doi:10.1007/bf02371251 · Cited by 66
Information contained in sensory nerve recordings made with intrafascicular electrodes
Goodall, E. V., Lefurge, T. M., & Horch, K. W. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83604 · Cited by 63
Self-citationMultielectrode intrafascicular and extraneural stimulation
Veltink, P. H., van Alsté, J. A., & Boom, H. B. K. (1989) · Medical and Biological Engineering and Computing · doi:10.1007/bf02442165 · Cited by 62
Diaphragm pacing by electrical stimulation of the phrenic nerve
Glenn, W. W., & Phelps, M. L. (1985) · Neurosurgery · doi:10.1097/00006123-198512000-00021 · Cited by 15
Cited by
Safety of long-term electrical peripheral nerve stimulation: review of the state of the art
Günter, C., Delbeke, J., & Ortiz-Catalan, M. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0474-8 · Cited by 198
Ortiz-Catalan, M., Brånemark, R., Håkansson, B., & Delbeke, J. (2012) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-11-33 · Cited by 144
“The self sizing spiral cuff design is inherently safer than rigid cuffs and more practical in the clinical setting because it can adapt to different nerve diameters [51].”
BackgroundInfluentialA review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133
Quantification of recruitment properties of multiple contact cuff electrodes
Grill, W. M., & Mortimer, J. T. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.506402 · Cited by 136
Grill, W. M., & Mortimer, J. T. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.736150 · Cited by 103
“Publisher Item Identifier S 1063-6528(98)09178-2. motor system neural prostheses allowing greater function and application to a larger patient population [24].”
Background
Metadata
- Authors
- Mortimer, T., Agnew, W. F., Horch, K., Citron, P., Creasey, G., & Kantor, C.
- Venue
- IEEE Transactions on Rehabilitation Engineering
- Published
- 1995-06
- Volume
- 3
- Issue
- 2
- Pages
- 145-154
- ISSN
- 1063-6528 (ISSN-L)
- OpenAlex
- W2124426773
- Cited by
- 33
- References
- 17
- FWCI
- 0.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.