HermesB: A Continuous Neural Recording System for Freely Behaving Primates
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Chronically implanted electrode arrays have enabled a broad range of advances in basic electrophysiology and neural prosthetics. Those successes motivate new experiments, particularly, the development of prototype implantable prosthetic processors for continuous use in freely behaving subjects, both monkeys and humans. However, traditional experimental techniques require the subject to be restrained, limiting both the types and duration of experiments. In this paper, we present a dual-channel, battery-powered neural recording system with an integrated three-axis accelerometer for use with chronically implanted electrode arrays in freely behaving primates. The recording system called HermesB, is self-contained, autonomous, programmable, and capable of recording broadband neural (sampled at 30 kS/s) and acceleration data to a removable compact flash card for up to 48 h. We have collected long-duration data sets with HermesB from an adult macaque monkey which provide insight into time scales and free behaviors inaccessible under traditional experiments. Variations in action potential shape and root-mean square (RMS) noise are observed across a range of time scales. The peak-to-peak voltage of action potentials varied by up to 30% over a 24-h period including step changes in waveform amplitude (up to 25%) coincident with high acceleration movements of the head. These initial results suggest that spike-sorting algorithms can no longer assume stable neural signals and will need to transition to adaptive signal processing methodologies to maximize performance. During physically active periods (defined by head-mounted accelerometer), significantly reduced 5-25-Hz local field potential (LFP) power and increased firing rate variability were observed. Using a threshold fit to LFP power, 93% of 403 5-min recording blocks were correctly classified as active or inactive, potentially providing an efficient tool for identifying different behavioral contexts in prosthetic applications. These results demonstrate the utility of the HermesB system and motivate using this type of system to advance neural prosthetics and electrophysiological experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 2×
“This implant has been adopted by many electrophysiology research laboratories and is now FD A approved for clinical trials with humans [6].”
BackgroundMethodLearning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
A high-performance brain–computer interface
Santhanam, G., Ryu, S. I., Yu, B. M., Afshar, A., & Shenoy, K. V. (2006) · Nature · doi:10.1038/nature04968 · Cited by 698
Self-citationCognitive Control Signals for Neural Prosthetics
Musallam, S., Corneil, B. D., Greger, B., Scherberger, H., & Andersen, R. A. (2004) · Science · doi:10.1126/science.1097938 · Cited by 663
Maynard, E. M., Nordhausen, C. T., & Normann, R. A. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95176-0 · Cited by 640
Destexhe, A., Contreras, D., & Steriade, M. (1999) · The Journal of Neuroscience · doi:10.1523/jneurosci.19-11-04595.1999 · Cited by 573 · cited 1×
“This differentiation in LFP power was observed across multiple channels and multiple days, and is consistent with previous results showing that 10–100 Hz LFP activity diminished during movement [26], [27] and increas d during sleep [28].”
ResultDonoghue, J. P., Sanes, J. N., Hatsopoulos, N. G., & Gaál, G. (1998) · Journal of Neurophysiology · doi:10.1152/jn.1998.79.1.159 · Cited by 538 · cited 1×
“This differentiation in LFP power was observed across multiple channels and multiple days, and is consistent with previous results showing that 10–100-Hz LFP activity diminished during movement [26], [27] and increased during sleep [28].”
ResultSuner, S., Fellows, M. R., Vargas-Irwin, C., Nakata, G. K., & Donoghue, J. P. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.857687 · Cited by 415 · cited 4×
“, s econds or minutes [10], [12]) and long timescales (e.”
BackgroundInfluential
Research works printed but not linked: 33
- 10.1109/TNSRE.2006.875547 · DOI · Paper page
- 10.1152/jn.00710.2006 · DOI · Paper page
- 10.1007/BF00274982 · DOI
- 10.1016/0166-4328(85)90070-1 · DOI · Paper page
- 10.1093/brain/107.2.385 · DOI · Paper page
- 10.1093/brain/107.2.385 · DOI · Paper page
- 10.1152/jn.00632.2002 · DOI · Paper page
- 10.1007/s00221-002-1166-x · DOI · Paper page
- 10.1109/IEMBS.2004.1404135 · DOI
- 10.1523/JNEUROSCI.3762-05.2006 · DOI · Paper page
- 10.1152/jn.00227.2003 · DOI
- 10.1146/annurev.neuro.27.070203.144233 · DOI · Paper page
- fee, 1996, variability of extracellular spike waveforms of cortical neurons, J Neurophysiol, 76, 3823, 10.1152/jn.1996.76.6.3823 · DOI · Paper page
- 10.1016/S0925-2312(99)00106-X · DOI
- 10.1109/TNSRE.2006.870495 · DOI · Paper page
- 10.1088/0954-898X/9/4/001 · doi:10.1088/0954-898x/9/4/001 · Paper page
- 10.1152/jn.00879.2005 · DOI · Paper page
- 10.1016/j.jneumeth.2005.04.017 · DOI
- 10.1016/j.jneumeth.2003.09.023 · DOI
- 10.1109/ISSCC.2006.1696288 · DOI · Paper page
- santhanam, 2003, local field potential activity varies with reach distance, direction, and speed in monkey pre-motor cortex, Soc Neurosci Abstracts
- tanji, 1976, anticipatory activity of motor cortex neurons in relation to direction of an intended movement, J Neurophysiol, 39, 1062, 10.1152/jn.1976.39.5.1062 · DOI · Paper page
- maynard, 1999, neuronal interactions improve cortical population coding of movement direction, J Neurosci, 19, 8083, 10.1523/JNEUROSCI.19-18-08083.1999 · DOI · Paper page
- taylor, 2002, direct cortical control of 3d neuroprosthetic devices, Science, 296, 1829, 10.1126/science.1070291 · DOI · Paper page
- 10.1038/416141a · DOI · Paper page
- 10.1152/jn.01245.2003 · DOI · Paper page
- 10.1109/86.847814 · DOI · Paper page
- 10.1097/00001756-200303240-00013 · DOI · Paper page
- wessberg, 2000, real-time prediction of hand trajectory by ensembles of cortical neurons in primates, Nature, 408, 361, 10.1038/35042582 · DOI · Paper page
- 10.1109/TNSRE.2005.854307 · DOI · Paper page
- sahani, 1999, Latent Variable Models for Neural Data Analysis
- bar-hillel, 2004, Advances in Neural Information Processing Systems 17, 105
- 10.1109/IEMBS.2004.1404138 · DOI · Paper page
Cited by
Yu, B. M., Cunningham, J. P., Santhanam, G., Ryu, S. I., Shenoy, K. V., & Sahani, M. (2009) · Journal of Neurophysiology · doi:10.1152/jn.90941.2008 · Cited by 656
Self-citationA high-performance neural prosthesis enabled by control algorithm design
Gilja, V., Nuyujukian, P., Chestek, C. A., Cunningham, J. P., Yu, B. M., Fan, J. M., Churchland, M. M., Kaufman, M. T., Kao, J. C., Ryu, S. I., et al. (2012) · Nature Neuroscience · doi:10.1038/nn.3265 · Cited by 564
Self-citationEmergence of a stable cortical map for neuroprosthetic control
Ganguly, K., & Carmena, J. M. (2009) · PLoS Biology · doi:10.1371/journal.pbio.1000153 · Cited by 578
“With continued improvements in technology [46,47], neuroprosthetic devices could be controlled through effortless recall of such a motor memory in a manner that mimics the natural process of skill acquisition and motor control.”
BackgroundSingle-neuron dynamics in human focal epilepsy
Truccolo, W., Donoghue, J. A., Hochberg, L. R., Eskandar, E. N., Madsen, J. R., Anderson, W. S., Brown, E. N., Halgren, E., & Cash, S. S. (2011) · Nature Neuroscience · doi:10.1038/nn.2782 · Cited by 514
A Fully Automated Approach to Spike Sorting
Chung, J. E., Magland, J. F., Barnett, A. H., Tolosa, V. M., Tooker, A. C., Lee, K. Y., Shah, K. G., Felix, S. H., Frank, L. M., & Greengard, L. F. (2017) · Neuron · doi:10.1016/j.neuron.2017.08.030 · Cited by 490
Using a Common Average Reference to Improve Cortical Neuron Recordings From Microelectrode Arrays
Ludwig, K. A., Miriani, R. M., Langhals, N. B., Joseph, M. D., Anderson, D. J., & Kipke, D. R. (2009) · Journal of Neurophysiology · doi:10.1152/jn.90989.2008 · Cited by 420
Chestek, C. A., Gilja, V., Nuyujukian, P., Foster, J. D., Fan, J. M., Kaufman, M. T., Churchland, M. M., Rivera-Alvidrez, Z., Cunningham, J. P., Ryu, S. I., et al. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/045005 · Cited by 350
Self-citationThe Science of Neural Interface Systems
Hatsopoulos, N. G., & Donoghue, J. P. (2009) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.051508.135241 · Cited by 377
A 128-Channel 6 mW Wireless Neural Recording IC With Spike Feature Extraction and UWB Transmitter
Chae, M. S., Yang, Z., Yuce, M. R., Hoang, L., & Liu, W. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2021607 · Cited by 369
Jarosiewicz, B., Sarma, A. A., Bacher, D., Masse, N. Y., Simeral, J. D., Sorice, B., Oakley, E. M., Blabe, C., Pandarinath, C., Gilja, V., et al. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aac7328 · Cited by 340
Self-citationThe Design of Integrated Circuits to Observe Brain Activity
Harrison, R. R. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922581 · Cited by 330
“Any on-chip spike sorting algorithm must deal with the fact that spike amplitudes and shapes change with time as the electrode array moves slightly in the tissue [ 47 ].”
BackgroundAdvanced Neurotechnologies for Chronic Neural Interfaces: New Horizons and Clinical Opportunities
Kipke, D. R., Shain, W., Buzsáki, G., Fetz, E., Henderson, J. M., Hetke, J. F., & Schalk, G. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.3879-08.2008 · Cited by 286
Ludwig, K. A., Langhals, N. B., Joseph, M. D., Richardson-Burns, S. M., Hendricks, J. L., & Kipke, D. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/1/014001 · Cited by 283
Primary Motor Cortex Tuning to Intended Movement Kinematics in Humans with Tetraplegia
Truccolo, W., Friehs, G. M., Donoghue, J. P., & Hochberg, L. R. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.4415-07.2008 · Cited by 272
Functional, But Not Anatomical, Separation of “What” and “When” in Prefrontal Cortex
Machens, C. K., Romo, R., & Brody, C. D. (2010) · The Journal of Neuroscience · doi:10.1523/jneurosci.3276-09.2010 · Cited by 260
Single-Unit Stability Using Chronically Implanted Multielectrode Arrays
Dickey, A. S., Suminski, A., Amit, Y., & Hatsopoulos, N. G. (2009) · Journal of Neurophysiology · doi:10.1152/jn.90920.2008 · Cited by 234
“An alternative approach would be to use one of the recently developed systems for continuously recording neural data from freely behaving macaques (Jackson and Fetz 2007; Jackson et al. 2006; Santhanam et al. 2007).”
BackgroundPerge, J. A., Homer, M. L., Malik, W. Q., Cash, S., Eskandar, E., Friehs, G., Donoghue, J. P., & Hochberg, L. R. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036004 · Cited by 243
Automated long-term recording and analysis of neural activity in behaving animals
Dhawale, A. K., Poddar, R., Wolff, S. B., Normand, V. A., Kopelowitz, E., & Ölveczky, B. P. (2017) · eLife · doi:10.7554/elife.27702 · Cited by 159
“…et al., 2014), but fail to address how neural activity is modulated outside of task context and across behavioral states (Arieli et al., 1996; Evarts, 1964; Gomez-Marin et al., 2014; Gulati et al., 2014; Lee and Dan, 2012; Rinberg et al., 2006; Santhanam et al., 2007; Wilson and McNaughton, 1994).”
BackgroundInfluentialIntracortical recording stability in human brain–computer interface users
Downey, J. E., Schwed, N., Chase, S. M., Schwartz, A. B., & Collinger, J. L. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab7a0 · Cited by 149
Translating the Brain-Machine Interface
Thakor, N. V. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007303 · Cited by 128
Sensors and Decoding for Intracortical Brain Computer Interfaces
Homer, M. L., Nurmikko, A. V., Donoghue, J. P., & Hochberg, L. R. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124640 · Cited by 121
Human cortical prostheses: lost in translation?
Ryu, S. I., & Shenoy, K. V. (2009) · Neurosurgical Focus · doi:10.3171/2009.4.focus0987 · Cited by 104
Self-citationImplantable neurotechnologies: a review of integrated circuit neural amplifiers
Ng, K. A., Greenwald, E., Xu, Y. P., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1431-3 · Cited by 83
Sponheim, C., Papadourakis, V., Collinger, J. L., Downey, J., Weiss, J., Pentousi, L., Elliott, K., & Hatsopoulos, N. G. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac3eaf · Cited by 66
“This subset of arrays generally displayed a gradual decrease in signal quality over time with variations from recording to recording presumably due to several factors such as micromovements of the array that may have occurred in the home cage such as sudden head accelerations (excluding our human participants) [27], h…”
BackgroundPrintable microscale interfaces for long-term peripheral nerve mapping and precision control
Otchy, T. M., Michas, C., Lee, B., Gopalan, K., Nerurkar, V., Gleick, J., Semu, D., Darkwa, L., Holinski, B. J., Chew, D. J., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-18032-4 · Cited by 35
“…interventions only provide snapshots of nerve function and fail to address how function is modulated outside of the experimental context or across physiological states (Arieli et al., 1996; Dhawale et al., 2017; Evarts, 1964; Gulati et al., 2014; Lee and Dan, 2012; Santhanam et al., 2007).”
BackgroundInfluentialToward Optimal Target Placement for Neural Prosthetic Devices
Cunningham, J. P., Yu, B. M., Gilja, V., Ryu, S. I., & Shenoy, K. V. (2008) · Journal of Neurophysiology · doi:10.1152/jn.90833.2008 · Cited by 25
Self-citationFan, C., Hahn, N., Kamdar, F., Avansino, D., Wilson, G. H., Hochberg, L., Shenoy, K. V., Henderson, J. M., & Willett, F. R. (2023) · arXiv · doi:10.48550/arxiv.2311.03611 · Cited by 19
Self-citation
Metadata
- Authors
- Santhanam, G., Linderman, M. D., Gilja, V., Afshar, A., Ryu, S. I., Meng, T. H., & Shenoy, K. V.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2007-11
- Volume
- 54
- Issue
- 11
- Pages
- 2037-2050
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2135762586
- Cited by
- 136
- References
- 8
- FWCI
- 5.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.