Regenerative Scaffold Electrodes for Peripheral Nerve Interfacing
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Advances in neural interfacing technology are required to enable natural, thought-driven control of a prosthetic limb. Here, we describe a regenerative electrode design in which a polymer-based thin-film electrode array is integrated within a thin-film sheet of aligned nanofibers, such that axons regenerating from a transected peripheral nerve are topographically guided across the electrode recording sites. Cultures of dorsal root ganglia were used to explore design parameters leading to cellular migration and neurite extension across the nanofiber/electrode array boundary. Regenerative scaffold electrodes (RSEs) were subsequently fabricated and implanted across rat tibial nerve gaps to evaluate device recording capabilities and influence on nerve regeneration. In 20 of these animals, regeneration was compared between a conventional nerve gap model and an amputation model. Characteristic shaping of regenerated nerve morphology around the embedded electrode array was observed in both groups, and regenerated axon profile counts were similar at the eight week end point. Implanted RSEs recorded evoked neural activity in all of these cases, and also in separate implantations lasting up to five months. These results demonstrate that nanofiber-based topographic cues within a regenerative electrode can influence nerve regeneration, to the potential benefit of a peripheral nerve interface suitable for limb amputees.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · cited 2×
“These drawbacks have driven the development of alternative regenerative electrode designs [12]–[19].”
BackgroundCarbon nanotube coating improves neuronal recordings
Keefer, E. W., Botterman, B. R., Romero, M. I., Rossi, A. F., & Gross, G. W. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.174 · Cited by 721 · cited 1×
“To compensate for the increased electrical impedance of the smaller electrodes, electrode surface area should be increased, either through conventional surface coatings such as sputtered or oxidized platinum or alternative materials such as carbon nanotubes [60].”
BackgroundFunctionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398 · cited 2×
“For stimulation or recording of bulk neural tissue, individual electrode sites should be larger and more widely spaced, as in successful extraneural designs [42], [58].”
BackgroundResultDhillon, G. S., Lawrence, S. M., Hutchinson, D. T., & Horch, K. W. (2004) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.02.006 · Cited by 354 · cited 2×
“Experiments with long-term human amputees demonstrate retained function of amputated nerves [2], though the long-term function of a regenerated segment of amputated nerve remains untested.”
BackgroundSelective control of muscle activation with a multipolar nerve cuff electrode
Veraart, C., Grill, W. M., & Mortimer, J. T. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.237694 · Cited by 320 · cited 1×
“More intimate nerve/electrode coupling might reduce thresholds for stimulating bulk nerve tissue in applications such as chronic pain blocking [43]–[46], bladder control [47], muscle activation [48], or enhancing regeneration [36], [37].”
BackgroundCriteria for the Selection of Materials for Implanted Electrodes
Geddes, L. A., & Roeder, R. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1581292 · Cited by 240 · cited 1×
“The electrode material might also bemodified, for example to a platinum and/or iridium based composition for stimulation [59].”
BackgroundOrderly recruitment of motor units under optical control in vivo
Llewellyn, M. E., Thompson, K. R., Deisseroth, K., & Delp, S. L. (2010) · Nature Medicine · doi:10.1038/nm.2228 · Cited by 217
Cuff electrodes for chronic stimulation and recording of peripheral nerve activity
Loeb, G. E., & Peck, R. A. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00123-9 · Cited by 215
Long-term pain control by direct peripheral-nerve stimulation.
Nashold, B. S., Goldner, J. L., Mullen, J. B., & Bright, D. S. (1982) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198264010-00001 · Cited by 184
Lago, N., Ceballos, D., J Rodrı́guez, F., Stieglitz, T., & Navarro, X. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.06.025 · Cited by 178
Cited by
Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics
Carnicer-Lombarte, A., Chen, S.-T., Malliaras, G. G., & Barone, D. G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.622524 · Cited by 454
“Similarly, cylindrical conduits implanted into a gap lesion can also be equipped with penetrating implants facing its bore, allowing axons to regrow around them for better interfacing (Musallam et al., 2007; Clements et al., 2013).”
BackgroundTan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., & Tyler, D. J. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/2/026002 · Cited by 175
Implantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording
Patil, A. C., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1430-4 · Cited by 175
Lee, S., Shi, Q., & Lee, C. (2019) · APL Materials · doi:10.1063/1.5063498 · Cited by 164
A review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133
Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review
Yildiz, K. A., Shin, A. Y., & Kaufman, K. R. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00667-5 · Cited by 113
Interfaces with the Peripheral Nerve for the Control of Neuroprostheses
del Valle, J., & Navarro, X. (2013) · International Review of Neurobiology · doi:10.1016/b978-0-12-420045-6.00002-x · Cited by 105
Tissue-engineered peripheral nerve interfaces
Spearman, B. S., Desai, V. H., Mobini, S., McDermott, M. D., Graham, J. B., Otto, K. J., Judy, J. W., & Schmidt, C. E. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701713 · Cited by 96
Innovations in Prosthetic Interfaces for the Upper Extremity
Kung, T. A., Bueno, R. A., Alkhalefah, G. K., Langhals, N. B., Urbanchek, M. G., & Cederna, P. S. (2013) · Plastic and Reconstructive Surgery · doi:10.1097/prs.0b013e3182a97e5f · Cited by 71
Update in facial nerve paralysis: tissue engineering and new technologies
Langhals, N. B., Urbanchek, M. G., Ray, A., & Brenner, M. J. (2014) · Current Opinion in Otolaryngology & Head and Neck Surgery · doi:10.1097/moo.0000000000000062 · Cited by 41
Phantom limb pain: peripheral neuromodulatory and neuroprosthetic approaches to treatment
Petersen, B. A., Nanivadekar, A. C., Chandrasekaran, S., & Fisher, L. E. (2019) · Muscle & Nerve · doi:10.1002/mus.26294 · Cited by 39
Fascicular nerve stimulation and recording using a novel double-aisle regenerative electrode
Delgado-Martínez, I., Righi, M., Santos, D., Cutrone, A., Bossi, S., D’Amico, S., Del Valle, J., Micera, S., & Navarro, X. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa6bac · Cited by 35
Flexible epineural strip electrode for recording in fine nerves
Lee, S., Yen, S.-C., Sheshadri, S., Martinez, I. D., Xue, N., Xiang, Z., Thakor, N. V., & Lee, C. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2466442 · Cited by 33
Gore, R. K., Choi, Y., Bellamkonda, R., & English, A. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016017 · Cited by 26
The Pursuit of Chronically Reliable Neural Interfaces: A Materials Perspective
Guo, L. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00599 · Cited by 19
Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review
Habibollahi, M., Jiang, D., Lancashire, H. T., & Demosthenous, A. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3430038 · Cited by 11
“…as the regenerative multielectrode interface, regenerative scaffold electrodes (RSE), double-aisle electrodes, and tissue-engineered electronic nerve interfaces (TEENI) have been developed, where supporting biomolecules and hydrogel scaffolds can be integrated to help repair injured nerves [32].”
Metadata
- Authors
- Clements, I. P., Mukhatyar, V. J., Srinivasan, A., Bentley, J. T., Andreasen, D. S., & Bellamkonda, R. V.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2013-07
- Volume
- 21
- Issue
- 4
- Pages
- 554-566
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2112899751
- Cited by
- 46
- References
- 17
- FWCI
- 1.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.