Ambient Mass Spectrometry
Abstract
A recent innovation in mass spectrometry is the ability to record mass spectra on ordinary samples, in their native environment, without sample preparation or preseparation by creating ions outside the instrument. In desorption electrospray ionization (DESI), the principal method described here, electrically charged droplets are directed at the ambient object of interest; they release ions from the surface, which are then vacuumed through the air into a conventional mass spectrometer. Extremely rapid analysis is coupled with high sensitivity and high chemical specificity. These characteristics are advantageously applied to high-throughput metabolomics, explosives detection, natural products discovery, and biological tissue imaging, among other applications. Future possible uses of DESI for in vivo clinical analysis and its adaptation to portable mass spectrometers are described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637
Mass Spectrometry Sampling Under Ambient Conditions with Desorption Electrospray Ionization
Takáts, Z., Wiseman, J. M., Gologan, B., & Cooks, R. G. (2004) · Science · doi:10.1126/science.1104404 · Cited by 3,324
Self-citationVersatile New Ion Source for the Analysis of Materials in Open Air under Ambient Conditions
Cody, R. B., Laramée, J. A., & Durst, H. D. (2005) · Analytical Chemistry · doi:10.1021/ac050162j · Cited by 2,483
Molecular Imaging of Biological Samples: Localization of Peptides and Proteins Using MALDI-TOF MS
Caprioli, R. M., Farmer, T. B., & Gile, J. (1997) · Analytical Chemistry · doi:10.1021/ac970888i · Cited by 2,234
Studying noncovalent protein complexes by electrospray ionization mass spectrometry
Loo, J. A. (1997) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1997)16:1<1::aid-mas1>3.0.co;2-l · Cited by 1,182
Takáts, Z., Wiseman, J. M., & Cooks, R. G. (2005) · Journal of Mass Spectrometry · doi:10.1002/jms.922 · Cited by 880
Self-citationA brief overview of the present status of the mechanisms involved in electrospray mass spectrometry
Kebarle, P. (2000) · Journal of Mass Spectrometry · doi:10.1002/1096-9888(200007)35:7<804::aid-jms22>3.0.co;2-q · Cited by 675
McEwen, C. N., McKay, R. G., & Larsen, B. S. (2005) · Analytical Chemistry · doi:10.1021/ac051470k · Cited by 596
Evidence for Macromolecular Protein Rings in the Absence of Bulk Water
Ruotolo, B. T., Giles, K., Campuzano, I., Sandercock, A. M., Bateman, R. H., & Robinson, C. V. (2005) · Science · doi:10.1126/science.1120177 · Cited by 596
Cited by
Recent advances in electrochemical sensing for hydrogen peroxide: a review
Chen, W., Cai, S., Ren, Q.-Q., Wen, W., & Zhao, Y.-D. (2012) · The Analyst · doi:10.1039/c1an15738h · Cited by 951
Nemes, P., & Vertes, A. (2007) · Analytical Chemistry · doi:10.1021/ac071181r · Cited by 817
Paper Spray for Direct Analysis of Complex Mixtures Using Mass Spectrometry
Wang, H., Liu, J., Cooks, R. G., & Ouyang, Z. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906314 · Cited by 771
Self-citationUnraveling the Mechanism of Electrospray Ionization
Konermann, L., Ahadi, E., Rodriguez, A. D., & Vahidi, S. (2013) · Analytical Chemistry · doi:10.1021/ac302789c · Cited by 735
Advances in Solid Phase Microextraction and Perspective on Future Directions
Reyes-Garcés, N., Gionfriddo, E., Gómez-Ríos, G. A., Alam, M. N., Boyacı, E., Bojko, B., Singh, V., Grandy, J., & Pawliszyn, J. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04502 · Cited by 735
Low-Temperature Plasma Probe for Ambient Desorption Ionization
Harper, J. D., Charipar, N. A., Mulligan, C. C., Zhang, X., Cooks, R. G., & Ouyang, Z. (2008) · Analytical Chemistry · doi:10.1021/ac801641a · Cited by 730
Self-citationDevelopment, Characterization, and Application of Paper Spray Ionization
Liu, J., Wang, H., Manicke, N. E., Lin, J.-M., Cooks, R. G., & Ouyang, Z. (2010) · Analytical Chemistry · doi:10.1021/ac902854g · Cited by 711
Self-citationDefinitions of terms relating to mass spectrometry (IUPAC Recommendations 2013)
Murray, K. K., Boyd, R. K., Eberlin, M. N., Langley, G. J., Li, L., & Naito, Y. (2013) · Pure and Applied Chemistry · doi:10.1351/pac-rec-06-04-06 · Cited by 687
Wiseman, J. M., Ifa, D. R., Song, Q., & Cooks, R. G. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200602449 · Cited by 626
Self-citationTetraphenylethylene-Based AIE-Active Probes for Sensing Applications
La, D. D., Bhosale, S. V., Jones, L. A., & Bhosale, S. V. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b12320 · Cited by 585
Organic Reactions in Microdroplets: Reaction Acceleration Revealed by Mass Spectrometry
Yan, X., Bain, R. M., & Cooks, R. G. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201602270 · Cited by 583
Self-citationMetal–Organic Frameworks for Food Safety
Wang, P.-L., Xie, L.-H., Joseph, E. A., Li, J.-R., Su, X.-O., & Zhou, H.-C. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00257 · Cited by 533
Ambient Sampling/Ionization Mass Spectrometry: Applications and Current Trends
Harris, G. A., Galhena, A. S., & Fernández, F. M. (2011) · Analytical Chemistry · doi:10.1021/ac200918u · Cited by 527
Current trends in explosive detection techniques
Caygill, J. S., Davis, F., & Higson, S. P. J. (2012) · Talanta · doi:10.1016/j.talanta.2011.11.043 · Cited by 525
Direct analysis in real time—a critical review on DART-MS
Gross, J. H. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-7316-0 · Cited by 496
Biomolecule Analysis by Ion Mobility Spectrometry
Bohrer, B. C., Merenbloom, S. I., Koeniger, S. L., Hilderbrand, A. E., & Clemmer, D. E. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.113001 · Cited by 492
Mass spectrometry imaging under ambient conditions
Wu, C., Dill, A. L., Eberlin, L. S., Cooks, R. G., & Ifa, D. R. (2013) · Mass Spectrometry Reviews · doi:10.1002/mas.21360 · Cited by 488
Self-citationMass Spectrometry Strategies in Metabolomics
Lei, Z., Huhman, D. V., & Sumner, L. W. (2011) · Journal of Biological Chemistry · doi:10.1074/jbc.r111.238691 · Cited by 481
Roach, P. J., Laskin, J., & Laskin, A. (2010) · The Analyst · doi:10.1039/c0an00312c · Cited by 479
Mass Spectrometry: Recent Advances in Direct Open Air Surface Sampling/Ionization
Monge, M. E., Harris, G. A., Dwivedi, P., & Fernández, F. M. (2013) · Chemical Reviews · doi:10.1021/cr300309q · Cited by 476
Desorption electrospray ionization mass spectrometry: Imaging drugs and metabolites in tissues
Wiseman, J. M., Ifa, D. R., Zhu, Y., Kissinger, C. B., Manicke, N. E., Kissinger, P. T., & Cooks, R. G. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0801066105 · Cited by 460
Self-citationPotyrailo, R. A. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00187 · Cited by 460
Watson, A. D. (2006) · Journal of Lipid Research · doi:10.1194/jlr.r600022-jlr200 · Cited by 455
Comparing and combining NMR spectroscopy and mass spectrometry in metabolomics
Pan, Z., & Raftery, D. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0687-8 · Cited by 444
Miniature and Fieldable Mass Spectrometers: Recent Advances
Snyder, D. T., Pulliam, C. J., Ouyang, Z., & Cooks, R. G. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b03070 · Cited by 420
Self-citationA concise review of mass spectrometry imaging
Amstalden van Hove, E. R., Smith, D. F., & Heeren, R. M. A. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.01.033 · Cited by 416
Mass Spectrometry, Review of the Basics: Electrospray, MALDI, and Commonly Used Mass Analyzers
El-Aneed, A., Cohen, A., & Banoub, J. (2009) · Applied Spectroscopy Reviews · doi:10.1080/05704920902717872 · Cited by 386
Ifa, D. R., Wu, C., Ouyang, Z., & Cooks, R. G. (2010) · The Analyst · doi:10.1039/b925257f · Cited by 384
Self-citationMass spectrometry‐based plant metabolomics: Metabolite responses to abiotic stress
Jorge, T. F., Rodrigues, J. A., Caldana, C., Schmidt, R., van Dongen, J. T., Thomas‐Oates, J., & António, C. (2016) · Mass Spectrometry Reviews · doi:10.1002/mas.21449 · Cited by 376
Advances in Mass Spectrometry for Lipidomics
Blanksby, S. J., & Mitchell, T. W. (2010) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.111808.073705 · Cited by 366
Weston, D. J. (2010) · The Analyst · doi:10.1039/b925579f · Cited by 357
Profiling metabolites and peptides in single cells
Rubakhin, S. S., Romanova, E. V., Nemes, P., & Sweedler, J. V. (2011) · Nature Methods · doi:10.1038/nmeth.1549 · Cited by 347
Cheng, G.-J., Zhang, X., Chung, L. W., Xu, L., & Wu, Y.-D. (2015) · Journal of the American Chemical Society · doi:10.1021/ja5112749 · Cited by 341
Ambient mass spectrometry: bringing MS into the “real world”
Alberici, R. M., Simas, R. C., Sanvido, G. B., Romão, W., Lalli, P. M., Benassi, M., Cunha, I. B. S., & Eberlin, M. N. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3808-3 · Cited by 340
In Vivo, In Situ Tissue Analysis Using Rapid Evaporative Ionization Mass Spectrometry
Schäfer, K., Dénes, J., Albrecht, K., Szaniszló, T., Balog, J., Skoumal, R., Katona, M., Tóth, M., Balogh, L., & Takáts, Z. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200902546 · Cited by 334
Ouyang, Z., & Cooks, R. G. (2009) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-060908-155229 · Cited by 323
Self-citationAmbient ionization mass spectrometry: A tutorial
Huang, M.-Z., Cheng, S.-C., Cho, Y.-T., & Shiea, J. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.06.017 · Cited by 320
Autonomous Discovery in the Chemical Sciences Part I: Progress
Coley, C. W., Eyke, N. S., & Jensen, K. F. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.201909987 · Cited by 317
Halogenated Compounds from Marine Algae
Cabrita, M. T., Vale, C., & Rauter, A. P. (2010) · Marine Drugs · doi:10.3390/md8082301 · Cited by 312
Ambient Ionization Mass Spectrometry
Huang, M.-Z., Yuan, C.-H., Cheng, S.-C., Cho, Y.-T., & Shiea, J. (2010) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.111808.073702 · Cited by 306
Van Berkel, G. J., Pasilis, S. P., & Ovchinnikova, O. (2008) · Journal of Mass Spectrometry · doi:10.1002/jms.1440 · Cited by 299
Shroff, R., Vergara, F., Muck, A., Svatoš, A., & Gershenzon, J. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0711730105 · Cited by 298
Hertkorn, N., Ruecker, C., Meringer, M., Gugisch, R., Frommberger, M., Perdue, E. M., Witt, M., & Schmitt-Kopplin, P. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1577-4 · Cited by 294
Advances in mass spectrometry-based metabolomics for investigation of metabolites
Ren, J.-L., Zhang, A.-H., Kong, L., & Wang, X.-J. (2018) · RSC Advances · doi:10.1039/c8ra01574k · Cited by 291
Spatial Metabolomics and Imaging Mass Spectrometry in the Age of Artificial Intelligence
Alexandrov, T. (2020) · Annual Review of Biomedical Data Science · doi:10.1146/annurev-biodatasci-011420-031537 · Cited by 284
Dried Blood Spots: Analysis and Applications
Demirev, P. A. (2013) · Analytical Chemistry · doi:10.1021/ac303205m · Cited by 284
Dunn, W. B. (2008) · Physical Biology · doi:10.1088/1478-3975/5/1/011001 · Cited by 278
Atmospheric pressure ion sources
Covey, T. R., Thomson, B. A., & Schneider, B. B. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20246 · Cited by 264
Ifa, D. R., Wiseman, J. M., Song, Q., & Cooks, R. G. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2006.08.003 · Cited by 261
Self-citationMethods for samples preparation in proteomic research
Bodzon-Kulakowska, A., Bierczynska-Krzysik, A., Dylag, T., Drabik, A., Suder, P., Noga, M., Jarzebinska, J., & Silberring, J. (2007) · Journal of Chromatography B · doi:10.1016/j.jchromb.2006.10.040 · Cited by 254
Sumner, L. W., Lei, Z., Nikolau, B. J., & Saito, K. (2015) · Natural Product Reports · doi:10.1039/c4np00072b · Cited by 233
Accelerated Hantzsch electrospray synthesis with temporal control of reaction intermediates
Bain, R. M., Pulliam, C. J., & Cooks, R. G. (2015) · Chemical Science · doi:10.1039/c4sc02436b · Cited by 230
Self-citationNative Mass Spectrometry of Membrane Proteins
Keener, J. E., Zhang, G., & Marty, M. T. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.0c04342 · Cited by 126
Körber, A., Anthony, I. G. M., & Heeren, R. M. A. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.4c05249 · Cited by 88
Guo, B., Chen, B., Liu, A., Zhu, W., & Yao, S. (2012) · Current Drug Metabolism · doi:10.2174/138920012803341401 · Cited by 80
Contrast Agent Mass Spectrometry Imaging Reveals Tumor Heterogeneity
Tata, A., Zheng, J., Ginsberg, H. J., Jaffray, D. A., Ifa, D. R., & Zarrine-Afsar, A. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b01992 · Cited by 34
Smith, R., Brookes, C., Morris, M., & Barran, P. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.5c02331 · Cited by 14
Metadata
- Authors
- Cooks, R. G., Ouyang, Z., Takats, Z., & Wiseman, J. M.
- Venue
- Science
- Published
- 2006-03-17
- Volume
- 311
- Issue
- 5767
- Pages
- 1566-1570
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2157520165
- Cited by
- 1,474
- References
- 21
- FWCI
- 34.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.