The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Multicolor Super-Resolution Imaging with Photo-Switchable Fluorescent Probes
Open accessAbstract
Recent advances in far-field optical nanoscopy have enabled fluorescence imaging with a spatial resolution of 20 to 50 nanometers. Multicolor super-resolution imaging, however, remains a challenging task. Here, we introduce a family of photo-switchable fluorescent probes and demonstrate multicolor stochastic optical reconstruction microscopy (STORM). Each probe consists of a photo-switchable “reporter” fluorophore that can be cycled between fluorescent and dark states, and an “activator” that facilitates photo-activation of the reporter. Combinatorial pairing of reporters and activators allows the creation of probes with many distinct colors. Iterative, color-specific activation of sparse subsets of these probes allows their localization with nanometer accuracy, enabling the construction of a super-resolution STORM image. Using this approach, we demonstrate multicolor imaging of DNA model samples and mammalian cells with 20- to 30-nanometer resolution. This technique will facilitate direct visualization of molecular interactions at the nanometer scale.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772
Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM)
Rust, M. J., Bates, M., & Zhuang, X. (2006) · Nature Methods · doi:10.1038/nmeth929 · Cited by 8,078
Self-citationNovotny, L., & Hecht, B. (2025) · Cambridge University Press eBooks · doi:10.1017/9781108781503 · Cited by 6,220
Ultra-High Resolution Imaging by Fluorescence Photoactivation Localization Microscopy
Hess, S. T., Girirajan, T. P. K., & Mason, M. D. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.091116 · Cited by 3,605
Hell, S. W. (2007) · Science · doi:10.1126/science.1137395 · Cited by 2,967
The Fluorescent Toolbox for Assessing Protein Location and Function
Giepmans, B. N. G., Adams, S. R., Ellisman, M. H., & Tsien, R. Y. (2006) · Science · doi:10.1126/science.1124618 · Cited by 2,770
Precise Nanometer Localization Analysis for Individual Fluorescent Probes
Thompson, R. E., Larson, D. R., & Webb, W. W. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75618-x · Cited by 2,320
Gustafsson, M. G. L. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406877102 · Cited by 2,224
Energy transfer: a spectroscopic ruler.
Stryer, L., & Haugland, R. P. (1967) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.58.2.719 · Cited by 1,957
Myosin V Walks Hand-Over-Hand: Single Fluorophore Imaging with 1.5-nm Localization
Yildiz, A., Forkey, J. N., McKinney, S. A., Ha, T., Goldman, Y. E., & Selvin, P. R. (2003) · Science · doi:10.1126/science.1084398 · Cited by 1,837
Ha, T., Enderle, T., Ogletree, D. F., Chemla, D. S., Selvin, P. R., & Weiss, S. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.13.6264 · Cited by 1,242
Wide-field subdiffraction imaging by accumulated binding of diffusing probes
Sharonov, A., & Hochstrasser, R. M. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0609643104 · Cited by 1,151
Illuminating Single Molecules in Condensed Matter
Moerner, W. E., & Orrit, M. (1999) · Science · doi:10.1126/science.283.5408.1670 · Cited by 1,129
Hell, S. W. (2003) · Nature Biotechnology · doi:10.1038/nbt895 · Cited by 1,003
Hypertonic media inhibit receptor-mediated endocytosis by blocking clathrin-coated pit formation.
Heuser, J. E., & Anderson, R. G. (1989) · The Journal of cell biology · doi:10.1083/jcb.108.2.389 · Cited by 919
Direct observation of base-pair stepping by RNA polymerase
Abbondanzieri, E. A., Greenleaf, W. J., Shaevitz, J. W., Landick, R., & Block, S. M. (2005) · Nature · doi:10.1038/nature04268 · Cited by 855
Two Distinct Actin Networks Drive the Protrusion of Migrating Cells
Ponti, A., Machacek, M., Gupton, S. L., Waterman-Storer, C. M., & Danuser, G. (2004) · Science · doi:10.1126/science.1100533 · Cited by 819
Kinesin and Dynein Move a Peroxisome in Vivo: A Tug-of-War or Coordinated Movement?
Kural, C., Kim, H., Syed, S., Goshima, G., Gelfand, V. I., & Selvin, P. R. (2005) · Science · doi:10.1126/science.1108408 · Cited by 613
Carbocyanine Dyes as Efficient Reversible Single-Molecule Optical Switch
Heilemann, M., Margeat, E., Kasper, R., Sauer, M., & Tinnefeld, P. (2005) · Journal of the American Chemical Society · doi:10.1021/ja044686x · Cited by 406
Single-molecule high-resolution imaging with photobleaching
Gordon, M. P., Ha, T., & Selvin, P. R. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0401638101 · Cited by 372
Short-Range Spectroscopic Ruler Based on a Single-Molecule Optical Switch
Bates, M., Blosser, T. R., & Zhuang, X. (2005) · Physical Review Letters · doi:10.1103/physrevlett.94.108101 · Cited by 364
Self-citationSuperresolution by localization of quantum dots using blinking statistics
Lidke, K. A., Rieger, B., Jovin, T. M., & Heintzmann, R. (2005) · Optics Express · doi:10.1364/opex.13.007052 · Cited by 361
RNA translocation and unwinding mechanism of HCV NS3 helicase and its coordination by ATP
Dumont, S., Cheng, W., Serebrov, V., Beran, R. K., Tinoco, I., Pyle, A. M., & Bustamante, C. (2006) · Nature · doi:10.1038/nature04331 · Cited by 351
Single-Molecule Three-Color FRET
Hohng, S., Joo, C., & Ha, T. (2004) · Biophysical Journal · doi:10.1529/biophysj.104.043935 · Cited by 328
Site-specific labeling of proteins with small molecules in live cells
Chen, I., & Ting, A. Y. (2005) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2004.12.003 · Cited by 314
Nanometer-localized multiple single-molecule fluorescence microscopy
Qu, X., Wu, D., Mets, L., & Scherer, N. F. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402155101 · Cited by 304
Ligand-induced conformational changes observed in single RNA molecules
Ha, T., Zhuang, X., Kim, H. D., Orr, J. W., Williamson, J. R., & Chu, S. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.16.9077 · Cited by 261
Self-citationTwo-Color Far-Field Fluorescence Nanoscopy
Donnert, G., Keller, J., Wurm, C. A., Rizzoli, S. O., Westphal, V., Schönle, A., Jahn, R., Jakobs, S., Eggeling, C., & Hell, S. W. (2007) · Biophysical Journal · doi:10.1529/biophysj.107.104497 · Cited by 256
Weber, K., Rathke, P. C., & Osborn, M. (1978) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.75.4.1820 · Cited by 255
Kim, S. Y., Gitai, Z., Kinkhabwala, A., Shapiro, L., & Moerner, W. E. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0604503103 · Cited by 205
Observation of Individual Microtubule Motor Steps in Living Cells with Endocytosed Quantum Dots
Nan, X., Sims, P. A., Chen, P., & Xie, X. S. (2005) · The Journal of Physical Chemistry B · doi:10.1021/jp056360w · Cited by 167
Cited by
Three-Dimensional Super-Resolution Imaging by Stochastic Optical Reconstruction Microscopy
Huang, B., Wang, W., Bates, M., & Zhuang, X. (2008) · Science · doi:10.1126/science.1153529 · Cited by 2,796
Self-citationSubdiffraction‐Resolution Fluorescence Imaging with Conventional Fluorescent Probes
Heilemann, M., van de Linde, S., Schüttpelz, M., Kasper, R., Seefeldt, B., Mukherjee, A., Tinnefeld, P., & Sauer, M. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200802376 · Cited by 1,866
Super-resolution fluorescence microscopy
Huang, B., Bates, M., & Zhuang, X. (2009) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.77.061906.092014 · Cited by 1,657
Self-citationChen, F., Tillberg, P. W., & Boyden, E. S. (2015) · Science · doi:10.1126/science.1260088 · Cited by 1,501
Evaluation of fluorophores for optimal performance in localization-based super-resolution imaging
Dempsey, G. T., Vaughan, J. C., Chen, K. H., Bates, M., & Zhuang, X. (2011) · Nature Methods · doi:10.1038/nmeth.1768 · Cited by 1,369
Self-citation
Metadata
- Authors
- Bates, M., Huang, B., Dempsey, G. T., & Zhuang, X.
- Venue
- Science
- Published
- 2007-09-21
- Volume
- 317
- Issue
- 5845
- Pages
- 1749-1753
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W1969103349
- Cited by
- 1,504
- References
- 31
- FWCI
- 36.44
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.