Long-Term Results of Catheter Ablation in Paroxysmal Atrial Fibrillation: Lessons From a 5-Year Follow-Up
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Background—: Paroxysmal atrial fibrillation (AF) naturally progresses toward chronic AF at an estimated rate of 15% to 30% over a 1- to 3-year period. Pulmonary vein (PV) isolation is increasingly performed for the treatment of drug-refractory paroxysmal AF. The long-term data on clinical outcome after circumferential PV isolation are limited. Methods and Results—: From 2003 to late 2004, 161 patients (121 men; age, 59.8±9.7 years) with symptomatic paroxysmal AF and normal left ventricular function underwent circumferential PV isolation guided by 3-dimensional mapping and double Lasso technique. Right-sided and left-sided continuous circular lesions encircling the ipsilateral PVs were placed with irrigated radiofrequency energy. The procedure end point was the absence of all PV spikes for at least 30 minutes after PV isolation verified by 2 Lasso catheters placed within the ipsilateral PVs. Sinus rhythm was present in 75 patients (46.6%) after the initial procedure during a median follow-up period of 4.8 years (0.33 to 5.5 years). A second procedure was performed in 66 and a third procedure in 12 patients. Recovered PV isolation conduction was observed in 62 of 66 patients (94.0%) during the second and in 8 of 12 patients (66.7%) during the third procedure. After a median of 1 (1 to 3) procedure, stable sinus rhythm was achieved in 128 of 161 patients (79.5%), whereas clinical improvement occurred in an additional 21 of 161 patients (13.0%) during a median follow-up of 4.6 years (0.33 to 5.5 years). Four patients in stable sinus rhythm died during follow-up. Progression toward chronic AF was observed in 4 patients (2.4%); however, only 2 patients reported symptoms. Conclusion—: In patients with paroxysmal AF and normal left ventricular function, circumferential PV isolation results in stable sinus rhythm in the majority of patients, and low incidence of chronic AF was observed after ablation during up to 5 years of follow-up.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary Veins
Haïssaguerre, M., Jaïs, P., Shah, D. C., Takahashi, A., Hocini, M., Quiniou, G., Garrigue, S., Le Mouroux, A., Le Métayer, P., & Clémenty, J. (1998) · New England Journal of Medicine · doi:10.1056/nejm199809033391003 · Cited by 7,975
Go, A. S., Hylek, E. M., Phillips, K. A., Chang, Y., Henault, L. E., Selby, J. V., & Singer, D. E. (2001) · JAMA · doi:10.1001/jama.285.18.2370 · Cited by 6,205
Feinberg, W. M. (1995) · Archives of Internal Medicine · doi:10.1001/archinte.155.5.469 · Cited by 2,274
Chen, S.-A., Hsieh, M.-H., Tai, C.-T., Tsai, C.-F., Prakash, V. S., Yu, W.-C., Hsu, T.-L., Ding, Y.-A., & Chang, M.-S. (1999) · Circulation · doi:10.1161/01.cir.100.18.1879 · Cited by 1,446
Electrophysiological Breakthroughs From the Left Atrium to the Pulmonary Veins
Haïssaguerre, M., Shah, D. C., Jaïs, P., Hocini, M., Yamane, T., Deisenhofer, I., Chauvin, M., Garrigue, S., & Clémenty, J. (2000) · Circulation · doi:10.1161/01.cir.102.20.2463 · Cited by 952
Calkins, H., Reynolds, M. R., Spector, P., Sondhi, M., Xu, Y., Martin, A., Williams, C. J., & Sledge, I. (2009) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.108.824789 · Cited by 847
Ouyang, F., Antz, M., Ernst, S., Hachiya, H., Mavrakis, H., Deger, F. T., Schaumann, A., Chun, J., Falk, P., Hennig, D., et al. (2005) · Circulation · doi:10.1161/01.cir.0000151289.73085.36 · Cited by 793
Self-citationPappone, C., Rosanio, S., Augello, G., Gallus, G., Vicedomini, G., Mazzone, P., Gulletta, S., Gugliotta, F., Pappone, A., Santinelli, V., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00577-1 · Cited by 781
Ouyang, F., Bänsch, D., Ernst, S., Schaumann, A., Hachiya, H., Chen, M., Chun, J., Falk, P., Khanedani, A., Antz, M., et al. (2004) · Circulation · doi:10.1161/01.cir.0000144459.37455.ee · Cited by 757
Self-citationVenice Chart International Consensus Document on Atrial Fibrillation Ablation
NATALE, A., RAVIELE, A., ARENTZ, T., CALKINS, H., CHEN, S., HAÏSSAGUERRE, M., HINDRICKS, G., HO, Y., KUCK, K. H., MARCHLINSKI, F., et al. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00816.x · Cited by 406
Self-citation
Cited by
Hindricks, G., Potpara, T., Dagres, N., Arbelo, E., Bax, J. J., Blomström-Lundqvist, C., Boriani, G., Castella, M., Dan, G.-A., Dilaveris, P. E., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa612 · Cited by 9,971
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000041 · Cited by 7,115
2012 focused update of the ESC Guidelines for the management of atrial fibrillation
Authors/Task Force Members, Camm, A. J., Lip, G. Y. H., De Caterina, R., Savelieva, I., Atar, D., Hohnloser, S. H., Hindricks, G., Kirchhof, P., ESC Committee for Practice Guidelines (CPG), et al. (2012) · EP Europace · doi:10.1093/europace/eus305 · Cited by 3,822
2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.03.022 · Cited by 2,955
2012 focused update of the ESC Guidelines for the management of atrial fibrillation
Authors/Task Force Members, Camm, A. J., Lip, G. Y. H., De Caterina, R., Savelieva, I., Atar, D., Hohnloser, S. H., Hindricks, G., Kirchhof, P., ESC Committee for Practice Guidelines (CPG), et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs253 · Cited by 2,899
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,675
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux274 · Cited by 1,164
Pathak, R. K., Middeldorp, M. E., Lau, D. H., Mehta, A. B., Mahajan, R., Twomey, D., Alasady, M., Hanley, L., Antic, N. A., McEvoy, R. D., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.09.028 · Cited by 949
Calkins, H., Reynolds, M. R., Spector, P., Sondhi, M., Xu, Y., Martin, A., Williams, C. J., & Sledge, I. (2009) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.108.824789 · Cited by 847
Ganesan, A. N., Shipp, N. J., Brooks, A. G., Kuklik, P., Lau, D. H., Lim, H. S., Sullivan, T., Roberts‐Thomson, K. C., & Sanders, P. (2013) · Journal of the American Heart Association · doi:10.1161/jaha.112.004549 · Cited by 800
“Mechanisms of Recurrence Mechanisms of recurrence were reported in 5 studies.(16,17,19,21,22) In these 5 studies, 3 of which reported data exclusively from PAF patients, PV reconnection was noted in 417 of 423 patients who underwent repeat ablation; the rate of ≥1 PV reconnection was 97.”
Paroxysmal AF Catheter Ablation With a Contact Force Sensing Catheter
Natale, A., Reddy, V. Y., Monir, G., Wilber, D. J., Lindsay, B. D., McElderry, H. T., Kantipudi, C., Mansour, M. C., Melby, D. P., Packer, D. L., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.04.072 · Cited by 472
Catheter Ablation of Long-Standing Persistent Atrial Fibrillation
Tilz, R. R., Rillig, A., Thum, A.-M., Arya, A., Wohlmuth, P., Metzner, A., Mathew, S., Yoshiga, Y., Wissner, E., Kuck, K.-H., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.04.060 · Cited by 469
Self-citationNeuzil, P., Reddy, V. Y., Kautzner, J., Petru, J., Wichterle, D., Shah, D., Lambert, H., Yulzari, A., Wissner, E., & Kuck, K.-H. (2013) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.113.000374 · Cited by 434
Self-citationReddy, V. Y., Dukkipati, S. R., Neuzil, P., Natale, A., Albenque, J.-P., Kautzner, J., Shah, D., Michaud, G., Wharton, M., Harari, D., et al. (2015) · Circulation · doi:10.1161/circulationaha.114.014092 · Cited by 383
Kautzner, J., Neuzil, P., Lambert, H., Peichl, P., Petru, J., Cihak, R., Skoda, J., Wichterle, D., Wissner, E., Yulzari, A., et al. (2015) · Europace · doi:10.1093/europace/euv057 · Cited by 374
Self-citationTaghji, P., El Haddad, M., Phlips, T., Wolf, M., Knecht, S., Vandekerckhove, Y., Tavernier, R., Nakagawa, H., & Duytschaever, M. (2018) · JACC: Clinical Electrophysiology · doi:10.1016/j.jacep.2017.06.023 · Cited by 350
Lip, G. Y., Tse, H. F., & Lane, D. A. (2012) · The Lancet · doi:10.1016/s0140-6736(11)61514-6 · Cited by 338
Low-Level Transcutaneous Electrical Vagus Nerve Stimulation Suppresses Atrial Fibrillation
Stavrakis, S., Humphrey, M. B., Scherlag, B. J., Hu, Y., Jackman, W. M., Nakagawa, H., Lockwood, D., Lazzara, R., & Po, S. S. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.12.026 · Cited by 334
Complications of Catheter Ablation of Atrial Fibrillation: A Systematic Review
Gupta, A., Perera, T., Ganesan, A., Sullivan, T., Lau, D. H., Roberts-Thomson, K. C., Brooks, A. G., & Sanders, P. (2013) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.113.000768 · Cited by 317
Scherr, D., Khairy, P., Miyazaki, S., Aurillac-Lavignolle, V., Pascale, P., Wilton, S. B., Ramoul, K., Komatsu, Y., Roten, L., Jadidi, A., et al. (2015) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.114.001943 · Cited by 303
“Long-Term Outcome of Persistent AF Ablation The concept of PVI as a treatment option for PAF is well established, with success rates of ≤80% during long-term follow-up.(1,3) However, significantly less evidence exists for catheter ablation in PsAF patients.”
BackgroundFriberg, L., Tabrizi, F., & Englund, A. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw087 · Cited by 270
Kirchhof, P., Lip, G. Y. H., Van Gelder, I. C., Bax, J., Hylek, E., Kaab, S., Schotten, U., Wegscheider, K., Boriani, G., Brandes, A., et al. (2012) · Europace · doi:10.1093/europace/eur241 · Cited by 243
“not sufficient to accrue adequate stroke numbers, especially when considering the reports on very late recurrences of AF after ablation.(226,227)”
BackgroundLip, G. Y. H., Andreotti, F., Fauchier, L., Huber, K., Hylek, E., Knight, E., Lane, D. A., Levi, M., Marin, F., Palareti, G., et al. (2011) · Europace · doi:10.1093/europace/eur126 · Cited by 223
“This is in line with current recommendations for AF and with the observation that AF tends to recur in many patients, including late recurrences in patients after AF ablation.(131)”
ResultArbelo, E., Brugada, J., Hindricks, G., Maggioni, A. P., Tavazzi, L., Vardas, P., Laroche, C., Anselme, F., Inama, G., Jais, P., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu001 · Cited by 212
Self-citationRillig, A., Tilz, R. R., Lin, T., Fink, T., Heeger, C.-H., Arya, A., Metzner, A., Mathew, S., Wissner, E., Makimoto, H., et al. (2016) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.115.003461 · Cited by 200
Self-citationFink, T., Schlüter, M., Heeger, C.-H., Lemes, C., Maurer, T., Reissmann, B., Riedl, J., Rottner, L., Santoro, F., Schmidt, B., et al. (2017) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.117.005114 · Cited by 189
Self-citationSchreiber, D., Rostock, T., Fröhlich, M., Sultan, A., Servatius, H., Hoffmann, B. A., Lüker, J., Berner, I., Schäffer, B., Wegscheider, K., et al. (2015) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.114.001672 · Cited by 175
El Haddad, M., Taghji, P., Phlips, T., Wolf, M., Demolder, A., Choudhury, R., Knecht, S., Vandekerckhove, Y., Tavernier, R., Nakagawa, H., et al. (2017) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.116.004867 · Cited by 160
Catheter ablation of atrial arrhythmias: state of the art
Lee, G., Sanders, P., & Kalman, J. M. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61463-9 · Cited by 151
Left atrial catheter ablation and ischemic stroke
Haeusler, K. G., Kirchhof, P., & Endres, M. (2012) · Stroke · doi:10.1161/strokeaha.111.627067 · Cited by 77
The use of low-level electromagnetic fields to suppress atrial fibrillation
Yu, L., Dyer, J. W., Scherlag, B. J., Stavrakis, S., Sha, Y., Sheng, X., Garabelli, P., Jacobson, J., & Po, S. S. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2014.12.022 · Cited by 31
Hojo, R., Fukamizu, S., Miyazawa, S., Kawamura, I., Sakurada, H., & Hiraoka, M. (2019) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-018-0489-x · Cited by 21
Metadata
- Authors
- Ouyang, F., Tilz, R., Chun, J., Schmidt, B., Wissner, E., Zerm, T., Neven, K., Köktürk, B., Konstantinidou, M., Metzner, A., Fuernkranz, A., & Kuck, K.-H.
- Venue
- Circulation
- Published
- 2010-12-07
- Volume
- 122
- Issue
- 23
- Pages
- 2368-2377
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2135738182
- Cited by
- 706
- References
- 30
- FWCI
- 37.40
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.