Trends in Cochlear Implants
Open accessThe DOI matches its Crossref record; 109 of the 109 references it cites were found in a registry or an index.
Abstract
More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic aspects of cochlear implants, focusing on their psychophysical, speech, music, and cognitive performance. This report also forecasts clinical and research trends related to presurgical evaluation, fitting protocols, signal processing, and postsurgical rehabilitation in cochlear implants. Finally, a future landscape in amplification is presented that requires a unique, yet complementary, contribution from hearing aids, middle ear implants, and cochlear implants to achieve a total solution to the entire spectrum of hearing loss treatment and management.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Speech Recognition with Primarily Temporal Cues
Shannon, R. V., Zeng, F.-G., Kamath, V., Wygonski, J., & Ekelid, M. (1995) · Science · doi:10.1126/science.270.5234.303 · Cited by 3,024
Self-citationRecognizing Spoken Words: The Neighborhood Activation Model
Luce, P. A., & Pisoni, D. B. (1998) · Ear and Hearing · doi:10.1097/00003446-199802000-00001 · Cited by 1,939
Gulick, W. L., & von Bekesy, G. (1963) · The American Journal of Psychology · doi:10.2307/1419812 · Cited by 1,727
Ann Otol Rhinol Laryngol [Suppl].
Cw, C. (1978) · PubMed · Cited by 1,313
Better speech recognition with cochlear implants
Wilson, B. S., Finley, C. C., Lawson, D. T., Wolford, R. D., Eddington, D. K., & Rabinowitz, W. M. (1991) · Nature · doi:10.1038/352236a0 · Cited by 1,190
Temporal information in speech: acoustic, auditory and linguistic aspects
Rosen, S. (1992) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1992.0070 · Cited by 1,130
Starr, A., Picton, T. W., Sininger, Y., Hood, L. J., & Berlin, C. I. (1996) · Brain · doi:10.1093/brain/119.3.741 · Cited by 988
Sharma, A., Dorman, M. F., & Spahr, A. J. (2002) · Ear and Hearing · doi:10.1097/00003446-200212000-00004 · Cited by 947
Chimaeric sounds reveal dichotomies in auditory perception
Smith, Z. M., Delgutte, B., & Oxenham, A. J. (2002) · Nature · doi:10.1038/416087a · Cited by 873
Language Development in Profoundly Deaf Children with Cochlear Implants
Svirsky, M. A., Robbins, A. M., Kirk, K. I., Pisoni, D. B., & Miyamoto, R. T. (2000) · Psychological Science · doi:10.1111/1467-9280.00231 · Cited by 647
Electrical Stimulation of the Auditory Nerve in Man
SIMMONS, F. B. (1966) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.1966.00760030004003 · Cited by 613
Electric-Acoustic Stimulation of the Auditory System
vonIlberg, C., Kiefer, J., Tillein, J., Pfenningdorff, T., Hartmann, R., Stürzebecher, E., & Klinke, R. (1999) · ORL · doi:10.1159/000027695 · Cited by 508
Cross-modal plasticity and cochlear implants
Lee, D. S., Lee, J. S., Oh, S. H., Kim, S.-K., Kim, J.-W., Chung, J.-K., Lee, M. C., & Kim, C. S. (2001) · Nature · doi:10.1038/35051653 · Cited by 480
Liberman, M. C. (1982) · The Journal of the Acoustical Society of America · doi:10.1121/1.388677 · Cited by 445
A Test for the Diagnosis of Dead Regions in the Cochlea
Moore, B. C. J., Huss, M., Vickers, D. A., Glasberg, B. R., & Alcántara, J. I. (2000) · British Journal of Audiology · doi:10.3109/03005364000000131 · Cited by 444
Dorman, M. F., Loizou, P. C., & Rainey, D. (1997) · The Journal of the Acoustical Society of America · doi:10.1121/1.419603 · Cited by 410
Lexical Effects on Spoken Word Recognition by Pediatric Cochlear Implant Users
Kirk, K. I., Pisoni, D. B., & Osberger, M. J. (1995) · Ear and Hearing · doi:10.1097/00003446-199510000-00004 · Cited by 405
Fishman, K. E., Shannon, R. V., & Slattery, W. H. (1997) · Journal of Speech, Language, and Hearing Research · doi:10.1044/jslhr.4005.1201 · Cited by 380
Combining acoustic and electrical hearing
Gantz, B. J., & Turner, C. W. (2003) · The Laryngoscope · doi:10.1097/00005537-200310000-00012 · Cited by 377
Music Perception with Temporal Cues in Acoustic and Electric Hearing
Kong, Y.-Y., Cruz, R., Jones, J. A., & Zeng, F.-G. (2004) · Ear and Hearing · doi:10.1097/01.aud.0000120365.97792.2f · Cited by 377
Self-citationRisk of Bacterial Meningitis in Children with Cochlear Implants
Reefhuis, J., Honein, M. A., Whitney, C. G., Chamany, S., Mann, E. A., Biernath, K. R., Broder, K., Manning, S., Avashia, S., Victor, M., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa031101 · Cited by 368
Multichannel electrical stimulation of the auditory nerve in man. I. Basic psychophysics
Shannon, R. V. (1983) · Hearing Research · doi:10.1016/0378-5955(83)90077-1 · Cited by 364
Predictors of Reading Skill Development in Children with Early Cochlear Implantation
Geers, A. E. (2003) · Ear and Hearing · doi:10.1097/01.aud.0000051690.43989.5d · Cited by 361
Long Term Results of Electrode Implantation and Electronic Stimulation of the Cochlea in Man
House, W. F., & Urban, J. (1973) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/000348947308200408 · Cited by 354
Speech and melody recognition in binaurally combined acoustic and electric hearing
Kong, Y.-Y., Stickney, G. S., & Zeng, F.-G. (2005) · The Journal of the Acoustical Society of America · doi:10.1121/1.1857526 · Cited by 351
Self-citationPisoni, D. B., & Cleary, M. (2003) · Ear and Hearing · doi:10.1097/01.aud.0000051692.05140.8e · Cited by 349
(1800) · Philosophical Transactions of the Royal Society of London · doi:10.1098/rstl.1800.0018 · Cited by 342
Auditory Prostheses Research with Multiple Channel Intracochlear Stimulation in Man
Eddington, D. K., Dobelle, W. H., Mladejovsky, M. G., Brackmann, D. E., & Parkin, J. L. (1978) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/00034894780870s602 · Cited by 334
Temporal pitch in electric hearing
Zeng, F.-G. (2002) · Hearing Research · doi:10.1016/s0378-5955(02)00644-5 · Cited by 314
Self-citationHuman hearing enhanced by noise11Published on the World Wide Web on 23 May 2000.
Zeng, F.-G., Fu, Q.-J., & Morse, R. (2000) · Brain Research · doi:10.1016/s0006-8993(00)02475-6 · Cited by 309
Self-citationHistopathology of Cochlear Implants in Humans
Nadol, J. B., Burgess, B. J., Gantz, B. J., Coker, N. J., Ketten, D. R., Kos, I., Roland, J. T., Shiao, J. Y., Eddington, D. K., Montandon, P., et al. (2001) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/000348940111000914 · Cited by 292
Cost-Utility Analysis of the Cochlear Implant in Children
Cheng, A. K. (2000) · JAMA · doi:10.1001/jama.284.7.850 · Cited by 279
Leake, P. A., Hradek, G. T., & Snyder, R. L. (1999) · The Journal of Comparative Neurology · doi:10.1002/(sici)1096-9861(19991004)412:4<543::aid-cne1>3.0.co;2-3 · Cited by 276
Djourno, A., & Eyriés, C. (1957) · PubMed · Cited by 264
Rosen, S., Faulkner, A., & Wilkinson, L. (1999) · The Journal of the Acoustical Society of America · doi:10.1121/1.428215 · Cited by 253
Speech intelligibility and localization in a multi-source environment
Hawley, M. L., Litovsky, R. Y., & Colburn, H. S. (1999) · The Journal of the Acoustical Society of America · doi:10.1121/1.424670 · Cited by 240
Correct tonotopic representation is necessary for complex pitch perception
Oxenham, A. J., Bernstein, J. G. W., & Penagos, H. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0306958101 · Cited by 238
Temporal processing and speech recognition in cochlear implant users
Fu, Q.-J. (2002) · NeuroReport · doi:10.1097/00001756-200209160-00013 · Cited by 237
Licklider, J. C. R., & Pollack, I. (1948) · The Journal of the Acoustical Society of America · doi:10.1121/1.1906346 · Cited by 228
Hearing after Congenital Deafness: Central Auditory Plasticity and Sensory Deprivation
Kral, A. (2002) · Cerebral Cortex · doi:10.1093/cercor/12.8.797 · Cited by 227
Skinner, M. W., Ketten, D. R., Holden, L. K., Harding, G. W., Smith, P. G., Gates, G. A., Neely, J. G., Kletzker, G. R., Brunsden, B., & Blocker, B. (2002) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s101620020013 · Cited by 223
Pisoni, D. B. (2000) · Ear and Hearing · doi:10.1097/00003446-200002000-00010 · Cited by 222
Cross-Modal Plasticity Underpins Language Recovery after Cochlear Implantation
Giraud, A.-L., Price, C. J., Graham, J. M., Truy, E., & Frackowiak, R. S. J. (2001) · Neuron · doi:10.1016/s0896-6273(01)00318-x · Cited by 218
McDermott, H. J., McKay, C. M., & Vandali, A. E. (1992) · The Journal of the Acoustical Society of America · doi:10.1121/1.402826 · Cited by 218
Klinke, R., Kral, A., Heid, S., Tillein, J., & Hartmann, R. (1999) · Science · doi:10.1126/science.285.5434.1729 · Cited by 215
Temporal modulation transfer functions in patients with cochlear implants
Shannon, R. V. (1992) · The Journal of the Acoustical Society of America · doi:10.1121/1.403807 · Cited by 212
Neurotrophic factor intervention restores auditory function in deafened animals
Shinohara, T., Bredberg, G., Ulfendahl, M., Pyykkö, I., Olivius, N. P., Kaksonen, R., Lindström, B., Altschuler, R., & Miller, J. M. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.032677999 · Cited by 212
Single fiber mapping of spatial excitation patterns in the electrically stimulated auditory nerve
van den Honert, C., & Stypulkowski, P. H. (1987) · Hearing Research · doi:10.1016/0378-5955(87)90167-5 · Cited by 209
Encoding Frequency Modulation to Improve Cochlear Implant Performance in Noise
Nie, K., Stickney, G., & Zeng, F.-G. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.839799 · Cited by 209
Self-citationAuditory system plasticity in children after long periods of complete deafness
Ponton, C. W., Don, M., Eggermont, J. J., Waring, M. D., Kwong, B., & Masuda, A. (1996) · NeuroReport · doi:10.1097/00001756-199612200-00013 · Cited by 194
Speech recognition with altered spectral distribution of envelope cues
Shannon, R. V., Zeng, F.-G., & Wygonski, J. (1998) · The Journal of the Acoustical Society of America · doi:10.1121/1.423774 · Cited by 193
Self-citationAuditory Nerve: Electrical Stimulation in Man
Simmons, F. B., Epley, J. M., Lummis, R. C., Guttman, N., Frishkopf, L. S., Harmon, L. D., & Zwicker, E. (1965) · Science · doi:10.1126/science.148.3666.104 · Cited by 191
Features of stimulation affecting tonal-speech perception: Implications for cochlear prostheses
Xu, L., Tsai, Y., & Pfingst, B. E. (2002) · The Journal of the Acoustical Society of America · doi:10.1121/1.1487843 · Cited by 191
Deafness-Induced Changes in the Auditory Pathway: Implications for Cochlear Implants
Shepherd, R. K., & Hardie, N. A. (2001) · Audiology and Neurotology · doi:10.1159/000046843 · Cited by 189
Rousche, P. J., & Normann, R. A. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.750552 · Cited by 187 · cited 1×
“…for totally biocompatible and totally implantable cochlear implants as well as other auditory prostheses and drug delivery devices that stimulate other auditory structures and promote nerve survival and even regeneration (McCreery et al., 1998; Rousche and Normann, 1999; Shinohara et al., 2002).”
BackgroundThe resolution of complex spectral patterns by cochlear implant and normal-hearing listeners
Henry, B. A., & Turner, C. W. (2003) · The Journal of the Acoustical Society of America · doi:10.1121/1.1561900 · Cited by 187
Snyder, R. L., Rebscher, S. J., Cao, K., Leake, P. A., & Kelly, K. (1990) · Hearing Research · doi:10.1016/0378-5955(90)90030-s · Cited by 180
Electrical stimulation of the auditory nerve
Javel, E., & Shepherd, R. K. (2000) · Hearing Research · doi:10.1016/s0378-5955(99)00186-0 · Cited by 179
Speech dynamic range and its effect on cochlear implant performance
Zeng, F.-G., Grant, G., Niparko, J., Galvin, J., Shannon, R., Opie, J., & Segel, P. (2002) · The Journal of the Acoustical Society of America · doi:10.1121/1.1423926 · Cited by 171
Self-citationThree Mechanisms of Hearing by Electrical Stimulation
Jones, R. C., Stevens, S. S., & Lurie, M. H. (1940) · The Journal of the Acoustical Society of America · doi:10.1121/1.1916103 · Cited by 169
Speech recognition with altered spectral distribution of envelope cues
Shannon, R. V., Zeng, F.-G., & Wygonski, J. (1996) · The Journal of the Acoustical Society of America · doi:10.1121/1.417043 · Cited by 169
Self-citationIdentification of temporal envelope cues in Chinese tone recognition
Fu, Q., & Zeng, F. (2000) · Asia Pacific Journal of Speech Language and Hearing · doi:10.1179/136132800807547582 · Cited by 166
Self-citationSpatial selectivity in a rotationally symmetric model of the electrically stimulated cochlea
Frijns, J. H. M., de Snoo, S. L., & ten Kate, J. H. (1996) · Hearing Research · doi:10.1016/0378-5955(96)00004-4 · Cited by 161
Amplitude Mapping and Phoneme Recognition in Cochlear Implant Listeners
Zeng, F.-G., & Galvin, J. J. (1999) · Ear and Hearing · doi:10.1097/00003446-199902000-00006 · Cited by 161
Self-citationCochlear Implants: Some Likely Next Steps
Wilson, B. S., Lawson, D. T., Müller, J. M., Tyler, R. S., & Kiefer, J. (2003) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.5.040202.121645 · Cited by 160
Fu, Q., Shannon, R. V., & Galvin, J. J. (2002) · The Journal of the Acoustical Society of America · doi:10.1121/1.1502901 · Cited by 149
Cochlear implant histopathology.
Linthicum, F. H., Fayad, J. N., Otto, S. R., Galey, F. R., & House, W. F. (1991) · PubMed · Cited by 143
Research Plan for Evaluating Subjects Presently Fitted with Implanted Auditory Prostheses
Bilger, R. C., Black, F. O., & Hopkinson, N. T. (1977) · Annals of Otology Rhinology & Laryngology · doi:10.1177/00034894770860s303 · Cited by 142
Report of the Eriksholm Workshop on Auditory Deprivation and Acclimatization
Arlinger, S. D., Gatehouse, S., Bentler, R. A., Byrne, D. M., Cox, R. M., Dirks, D. D., Humes, L. E., Neuman, A. C., Ponton, C. W., Robinson, K., et al. (1996) · Ear and Hearing · doi:10.1097/00003446-199617031-00009 · Cited by 138
Electrical Stimulation of Eighth Cranial Nerve
Doyle, J. H., DOYLE, J. B., & Turnbull, F. M. (1964) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.1964.00750040400005 · Cited by 138
Phase-locking of auditory-nerve discharges to sinusoidal electric stimulation of the cochlea
Dynes, S., & Delgutte, B. (1992) · Hearing Research · doi:10.1016/0378-5955(92)90011-b · Cited by 137
Quadrupolar stimulation for cochlear prostheses: modeling and experimental data
Jolly, C. N., Spelman, F. A., & Clopton, B. M. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.508549 · Cited by 132
Skinner, M. W., Holden, L. K., Holden, T. A., Dowell, R. C., Seligman, P., Brimacombe, J. A., & Beiter, A. L. (1991) · Ear and Hearing · doi:10.1097/00003446-199102000-00002 · Cited by 130
The Results of Electrical Stimulation of the Cochlea in Human Sensory Deafness
Michelson, R. P. (1971) · Annals of Otology Rhinology & Laryngology · doi:10.1177/000348947108000618 · Cited by 128
The Mechanism of Hearing by Electrical Stimulation
Stevens, S. S., & Jones, R. C. (1939) · The Journal of the Acoustical Society of America · doi:10.1121/1.1915984 · Cited by 127
Mandarin tone recognition in cochlear-implant subjects
Wei, C., Cao, K., & Zeng, F. (2004) · Hearing Research · doi:10.1016/j.heares.2004.06.002 · Cited by 125
Self-citationAuditory nerve fiber responses to electric stimulation: Modulated and unmodulated pulse trains
Litvak, L., Delgutte, B., & Eddington, D. (2001) · The Journal of the Acoustical Society of America · doi:10.1121/1.1375140 · Cited by 122
Cochlear Implants: Auditory Prostheses and Electric Hearing
(2004) · Springer handbook of auditory research · doi:10.1007/978-0-387-22585-2 · Cited by 117
Loudness-Coding Mechanisms Inferred from Electric Stimulation of the Human Auditory System
Zeng, F., & Shannon, R. V. (1994) · Science · doi:10.1126/science.8160013 · Cited by 117
Self-citationA Cost-Utility Scenario Analysis of Bilateral Cochlear Implantation
Summerfield, A. Q., Marshall, D. H., Barton, G., & Bloor, K. E. (2002) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.128.11.1255 · Cited by 111
Cost-Utility of the Cochlear Implant in Adults A Meta-analysis
Cheng, A. K. (1999) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.125.11.1214 · Cited by 102
Speaker recognition with temporal cues in acoustic and electric hearing
Vongphoe, M., & Zeng, F. (2005) · The Journal of the Acoustical Society of America · doi:10.1121/1.1944507 · Cited by 93
Self-citationCortical Responses to Cochlear Implant Stimulation: Channel Interactions
Bierer, J. A., & Middlebrooks, J. C. (2004) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s10162-003-3057-7 · Cited by 88
Loudness balance between electric and acoustic stimulation
Zeng, F., & Shannon, R. V. (1992) · Hearing Research · doi:10.1016/0378-5955(92)90024-h · Cited by 85
Self-citationLearning, Memory, and Cognitive Processes in Deaf Children Following Cochlear Implantation
Pisoni, D. B., & Cleary, M. (2004) · Springer handbook of auditory research · doi:10.1007/978-0-387-22585-2_9 · Cited by 84
Signal Coding in Cochlear Implants: Exploiting Stochastic Effects of Electrical Stimulation
Rubinstein, J. T., & Hong, R. (2003) · Annals of Otology Rhinology & Laryngology · doi:10.1177/00034894031120s904 · Cited by 77
McCreery, D. B., Shannon, R. V., Moore, J. K., & Chatterjee, M. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.736153 · Cited by 76
Lumped-parameter model for in vivo cochlear stimulation
Suesserman, M. F., & Spelman, F. A. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.216407 · Cited by 74
Pfingst, B. E., Franck, K. H., Xu, L., Bauer, E., & Zwolan, T. A. (2001) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s101620010065 · Cited by 72
Vollmer, M., Snyder, R. L., Leake, P. A., Beitel, R. E., Moore, C. M., & Rebscher, S. J. (1999) · Journal of Neurophysiology · doi:10.1152/jn.1999.82.6.2883 · Cited by 62
Encoding loudness by electric stimulation of the auditory nerve
Zeng, F., Galvin, J. J., & Zhang, C. (1998) · Neuroreport · doi:10.1097/00001756-199806010-00033 · Cited by 56
Self-citationMoore, C. M., Vollmer, M., Leake, P. A., Snyder, R. L., & Rebscher, S. J. (2002) · Hearing Research · doi:10.1016/s0378-5955(01)00415-4 · Cited by 54
On Hearing by Electrical Stimulation
Stevens, S. S. (1937) · The Journal of the Acoustical Society of America · doi:10.1121/1.1902000 · Cited by 45
Psychometric functions and temporal integration in electric hearing
Donaldson, G. S., Viemeister, N. F., & Nelson, D. A. (1997) · The Journal of the Acoustical Society of America · doi:10.1121/1.418330 · Cited by 45
Cochlear implant histopathology
Linthicum, F. H., Doherty, J. K., López, I. A., & Ishiyama, A. (2017) · World Journal of Otorhinolaryngology - Head and Neck Surgery · doi:10.1016/j.wjorl.2017.12.008 · Cited by 45
Svirsky, M. A. (2001) · Acta Oto-Laryngologica · doi:10.1080/000164801300043767 · Cited by 44
On Hearing by Electrical Stimulation
Stevens, S. S. (1937) · The Journal of the Acoustical Society of America · doi:10.1121/1.1915894 · Cited by 41
Coding strategies for multichannel cochlear prostheses.
Wilson, B. S., Lawson, D. T., Finley, C. C., & Wolford, R. D. (1991) · PubMed · Cited by 38
Effects of electrode configuration on threshold functions for electrical stimulation of the cochlea
Pfingst, B. E., Morris, D. J., & Miller, A. L. (1995) · Hearing Research · doi:10.1016/0378-5955(95)00037-5 · Cited by 33
Speech perception by prelingually deaf children and postlingually deaf adults with cochlear implant.
Tyler, R. S., Parkinson, A. J., Fryauf-Bertschy, H., Lowder, M., Parkinson, W. S., Gantz, B. J., & Kelsay, D. M. R. (1997) · PubMed · Cited by 28
Auditory Prostheses in Perspective
Bilger, R. C., & Black, F. O. (1977) · Annals of Otology Rhinology & Laryngology · doi:10.1177/00034894770860s301 · Cited by 27
Svirsky, M. A. (2000) · The Journal of the Acoustical Society of America · doi:10.1121/1.428459 · Cited by 25
Psychoacoustic evaluation of present prostheses.
Rc, B. (1977) · PubMed · Cited by 24
Acoustic and Electrical Pattern Analysis of Consonant Perceptual Cues Used by Cochlear Implant Users
Teoh, S. W., Neuburger, H. S., & Svirsky, M. A. (2003) · Audiology and Neurotology · doi:10.1159/000072000 · Cited by 22
Djourno, A., Eyriés, C., & Vallancien, B. (1957) · PubMed · Cited by 21
Djourno, A., Eyriés, C., & Vallancien, P. (2000) · PubMed · Cited by 14
Hearing Performance with the Auditory Prosthesis
Bilger, R. C., & Hopkinson, N. T. (1977) · Annals of Otology Rhinology & Laryngology · doi:10.1177/00034894770860s310 · Cited by 13
Electrical Stimulation of the Auditory Nerve and Auditory Prostheses: A Review of the Literature
Bilger, R. C. (1977) · Annals of Otology Rhinology & Laryngology · doi:10.1177/00034894770860s302 · Cited by 8
Subject acceptance of implanted auditory prosthesis.
Rc, B., Stenson, N., & Jl, P. (1977) · PubMed · Cited by 5
Cited by
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
“, a 70% sentence recognition score would support a telephone conversation [40].”
BackgroundResultInfluentialSelf-citationWireless Power Transfer Strategies for Implantable Bioelectronics
Agarwal, K., Jegadeesan, R., Guo, Y.-X., & Thakor, N. V. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2683520 · Cited by 540
Power Approaches for Implantable Medical Devices
Amar, A., Kouki, A., & Cao, H. (2015) · Sensors · doi:10.3390/s151128889 · Cited by 432
Weiland, J. D., Liu, W., & Humayun, M. S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.060804.100435 · Cited by 371
Technological, biological, and acoustical constraints to music perception in cochlear implant users
Limb, C. J., & Roy, A. T. (2014) · Hearing Research · doi:10.1016/j.heares.2013.04.009 · Cited by 274
Metadata
- Authors
- Zeng, F.-G.
- Venue
- Trends in Amplification
- Publisher
- SAGE Publications
- Published
- 2004-12
- Volume
- 8
- Issue
- 1
- Pages
- 1-34
- ISSN
- 1084-7138 (ISSN-L)
- OpenAlex
- W2159742781
- Cited by
- 401
- References
- 109
- FWCI
- 6.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.