Multinational Study of Subcutaneous Model-Predictive Closed-Loop Control in Type 1 Diabetes Mellitus: Summary of the Results
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Background: In 2008–2009, the first multinational study was completed comparing closed-loop control (artificial pancreas) to state-of-the-art open-loop therapy in adults with type 1 diabetes mellitus (T1DM). Methods: The design of the control algorithm was done entirely in silico, i.e., using computer simulation experiments with N = 300 synthetic “subjects” with T1DM instead of traditional animal trials. The clinical experiments recruited 20 adults with T1DM at the Universities of Virginia (11); Padova, Italy (6); and Montpellier, France (3). Open-loop and closed-loop admission was scheduled 3–4 weeks apart, continued for 22 h (14.5 h of which were in closed loop), and used a continuous glucose monitor and an insulin pump. The only difference between the two sessions was that insulin dosing was performed by the patient under a physician's supervision during open loop, whereas insulin dosing was performed by a control algorithm during closed loop. Results: In silico design resulted in rapid (less than 6 months compared to years of animal trials) and cost-effective system development, testing, and regulatory approvals in the United States, Italy, and France. In the clinic, compared to open-loop, closed-loop control reduced nocturnal hypoglycemia (blood glucose below 3.9 mmol/liter) from 23 to 5 episodes (p < .01) and increased the amount of time spent overnight within the target range (3.9 to 7.8 mmol/liter) from 64% to 78% (p = .03). Conclusions: In silico experiments can be used as viable alternatives to animal trials for the preclinical testing of insulin treatment strategies. Compared to open-loop treatment under identical conditions, closed-loop control improves the overnight regulation of diabetes.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Only three months later, in April 2008, the first human trials began at the Universities of Virginia, Montpellier (France), and Padova (Italy), using a control system designed entirely in silico.69”
From Developing the UVA/Padova Type 1 Diabetes Simulator: Modeling, Validation, Refinements, and Utility (2023) · cites this paper as [69]
Citations
Cites
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes
Hovorka, R., Canonico, V., Chassin, L. J., Haueter, U., Massi-Benedetti, M., Federici, M. O., Pieber, T. R., Schaller, H. C., Schaupp, L., Vering, T., et al. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/4/010 · Cited by 1,274
Meal Simulation Model of the Glucose-Insulin System
Dalla Man, C., Rizza, R. A., & Cobelli, C. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.893506 · Cited by 955
Self-citationIn Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes
Kovatchev, B. P., Breton, M., Dalla Man, C., & Cobelli, C. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300106 · Cited by 760
Self-citationWeinzimer, S. A., Steil, G. M., Swan, K. L., Dziura, J., Kurtz, N., & Tamborlane, W. V. (2008) · Diabetes Care · doi:10.2337/dc07-1967 · Cited by 567
A model-based algorithm for blood glucose control in Type I diabetic patients
Parker, R. S., Doyle, F. J., & Peppas, N. A. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.740877 · Cited by 500 · cited 4×
“, by a series of computer simulations performed on virtual subjects; (2) clinical experiments performed in three independent centers in the United States, Italy, and France, which enhances the external validity of the results; and (3) automated (as opposed to manual) transfer of CGM data to the control system, which b…”
BackgroundInfluentialFeasibility of Automating Insulin Delivery for the Treatment of Type 1 Diabetes
Steil, G. M., Rebrin, K., Darwin, C., Hariri, F., & Saad, M. F. (2006) · Diabetes · doi:10.2337/db06-0419 · Cited by 473
Hovorka, R., Allen, J. M., Elleri, D., Chassin, L. J., Harris, J., Xing, D., Kollman, C., Hovorka, T., Larsen, A. M. F., Nodale, M., et al. (2010) · The Lancet · doi:10.1016/s0140-6736(09)61998-x · Cited by 450
Continuous glucose monitoring and closed‐loop systems
Hovorka, R. (2006) · Diabetic Medicine · doi:10.1111/j.1464-5491.2005.01672.x · Cited by 443 · cited 4×
“The clinical experiments recruited 20 adults with T1DM at the Universities of Virginia (11); Padova, Italy (6); and Montpellier, France (3).”
BackgroundInfluentialA Bihormonal Closed-Loop Artificial Pancreas for Type 1 Diabetes
El-Khatib, F. H., Russell, S. J., Nathan, D. M., Sutherlin, R. G., & Damiano, E. R. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3000619 · Cited by 403
An Artificial Endocrine Pancreas
Albisser, A. M., Leibel, B. S., Ewart, T. G., Davidovac, Z., Botz, C. K., & Zingg, W. (1974) · Diabetes · doi:10.2337/diab.23.5.389 · Cited by 379
Model Predictive Control of Type 1 Diabetes: An in Silico Trial
Magni, L., Raimondo, D. M., Bossi, L., Dalla Man, C., De Nicolao, G., Kovatchev, B., & Cobelli, C. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100603 · Cited by 317
Self-citationStatistical Tools to Analyze Continuous Glucose Monitor Data
Clarke, W., & Kovatchev, B. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0138 · Cited by 249
Self-citationClarke, W. L., Anderson, S., Breton, M., Patek, S., Kashmer, L., & Kovatchev, B. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300506 · Cited by 185
Self-citationImplantable closed-loop glucose-sensing and insulin delivery: the future for insulin pump therapy
Renard, É. (2002) · Current Opinion in Pharmacology · doi:10.1016/s1471-4892(02)00216-3 · Cited by 171
Closing the Loop: The Adicol Experience
Hovorka, R., Chassin, L. J., Wilinska, M. E., Canonico, V., Akwi, J. A., Federici, M. O., Massi-Benedetti, M., Hutzli, I., Zaugg, C., Kaufmann, H., et al. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/152091504774197990 · Cited by 154
Detection of a Meal Using Continuous Glucose Monitoring
Dassau, E., Bequette, B. W., Buckingham, B. A., & Doyle, F. J. (2008) · Diabetes Care · doi:10.2337/dc07-1293 · Cited by 143
Bruttomesso, D., Farret, A., Costa, S., Marescotti, M. C., Vettore, M., Avogaro, A., Tiengo, A., Dalla Man, C., Place, J., Facchinetti, A., et al. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300504 · Cited by 141
Self-citationThe subcutaneous route to insulin dependent diabetes therapy
Bellazzi, R., Nucci, G., & Cobelli, C. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.897828 · Cited by 138
Self-citationClosed-loop and Open-loop Devices for Blood Glucose Control in Normal and Diabetic Subjects
Santiago, J. V., Clemens, A. H., Clarke, W. L., & KIPNIS, D. M. (1978) · Diabetes · doi:10.2337/diab.28.1.71 · Cited by 134
Self-citationPreventing Hypoglycemia Using Predictive Alarm Algorithms and Insulin Pump Suspension
Buckingham, B., Cobry, E., Clinton, P., Gage, V., Caswell, K., Kunselman, E., Cameron, F., & Chase, H. P. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0032 · Cited by 132
Run-to-run control of blood glucose concentrations for people with type 1 diabetes mellitus
Owens, C., Zisser, H., Jovanovic, L., Srinivasan, B., Bonvin, D., & Doyle, F. J. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.872818 · Cited by 122
The Artificial Pancreas: How Sweet Engineering Will Solve Bitter Problems
Klonoff, D. C. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100112 · Cited by 84
Prandial Insulin Dosing Using Run-to-Run Control
Palerm, C. C., Zisser, H., Bevier, W. C., Jovanovič, L., & Doyle, F. J. (2007) · Diabetes Care · doi:10.2337/dc06-2115 · Cited by 74
Chan, A., Breton, M. D., & Kovatchev, B. P. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200516 · Cited by 10
Self-citation
Cited by
Artificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
“(31) reported a study in which the aggressiveness of the controller was individualized using patient parameters such as body weight, carbohydrate ratio, and insulin basal rate.”
BackgroundSelf-citationNocturnal Glucose Control with an Artificial Pancreas at a Diabetes Camp
Phillip, M., Battelino, T., Atlas, E., Kordonouri, O., Bratina, N., Miller, S., Biester, T., Avbelj Stefanija, M., Muller, I., Nimri, R., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1206881 · Cited by 435
Closed-Loop Artificial Pancreas Systems: Engineering the Algorithms
Doyle, F. J., Huyett, L. M., Lee, J. B., Zisser, H. C., & Dassau, E. (2014) · Diabetes Care · doi:10.2337/dc13-2108 · Cited by 394
“Fully automated closed-loop control showed a comparatively lower time in range, although these systems require considerably less patient effort (9,17,24,26,27,31,34,35,41,42).”
BackgroundClosed-loop insulin delivery from bench to clinical practice
Hovorka, R. (2011) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2011.32 · Cited by 342
In silico clinical trials: how computer simulation will transform the biomedical industry
Viceconti, M., Henney, A., & Morley-Fletcher, E. (2016) · International Journal of Clinical Trials · doi:10.18203/2349-3259.ijct20161408 · Cited by 289
Metadata
- Authors
- Kovatchev, B., Cobelli, C., Renard, E., Anderson, S., Breton, M., Patek, S., Clarke, W., Bruttomesso, D., Maran, A., Costa, S., Avogaro, A., Man, C. D., Facchinetti, A., Magni, L., De Nicolao, G., Place, J., & Farret, A.
- Affiliations
- University of Virginia (US)
- University of Padua (IT)
- Department of Endocrinology and UMR CNRS, CHU and University of Montpellier, Montpellier, France
- University of Pavia (IT)
- Department of System and Informatics, University of Pavia, Pavia, Italy;
- Centre National de la Recherche Scientifique (FR)
- Corresponding author
- Kovatchev, Boris
- ORCID
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2010-11
- Volume
- 4
- Issue
- 6
- Pages
- 1374-1381
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC3005047
- OpenAlex
- W2134017961
- Cited by
- 200
- References
- 25
- Citations by year
- 2026: 2 · 2024: 2 · 2023: 6 · 2022: 5 · 2021: 9 · 2020: 4 · 2019: 15 · 2018: 11 · 2017: 14 · 2016: 13 · 2015: 19 · 2014: 29 · 2013: 32 · 2012: 24
- FWCI
- 17.19
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Padua Research Archive (University of Padova) (submittedVersion)
- Funders
- National Institutes of Health (5r01dk051562-23)
- National Institute of Diabetes and Digestive and Kidney Diseases (R01DK 51562)
- National Center for Research Resources (M01RR000847, M01-RR 00847)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Keywords
- type 1 diabetes, feedback control, model predictive control, artificial pancreas, in silico design, computer simulation, nocturnal hypoglycemia, continuous glucose monitoring, insulin pump
- MeSH terms
- Adolescent, Adult, Aged, Algorithms, Blood Glucose, Child, Computer Simulation, Diabetes Mellitus, Type 1, Female, France, Glycated Hemoglobin, Humans, Hypoglycemia, Hypoglycemic Agents, Insulin, Insulin Infusion Systems, Italy, Male, Middle Aged, Models, Biological, Monitoring, Physiologic, Pilot Projects, Time Factors, Virginia, Treatment Outcome, Pancreas, Artificial, Drug Dosage Calculations, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.