Ambulatory monitoring in the diagnosis and management of obstructive sleep apnoea syndrome
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
Obstructive sleep apnoea (OSA) is a highly prevalent disorder associated with complications such as arterial hypertension, cardiovascular diseases and traffic accidents. The resources allocated for OSA are insufficient and OSA is a significant public health problem. Portable recording devices have been developed for the detection of OSA syndrome and have proved capable of providing an equivalent diagnosis to in-laboratory polysomnography (PSG), at least in patients with a high pre-test probability of OSA syndrome. PSG becomes important in patients who have symptoms and certain comorbidities such as chronic obstructive pulmonary disease or stroke, as well as in patients with a clinical history suggesting a different sleep disorder. Continuous positive airway pressure is the most effective treatment in OSA. Ambulatory monitoring of the therapeutic modalities has been evaluated to enhance the care process and reduce costs compared to the conventional approach, without sacrificing efficiency. This review evaluates the role of portable monitoring devices in the diagnostic process of OSA and the search for alternative strategies based on ambulatory management protocols.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Berry, R. B., Budhiraja, R., Gottlieb, D. J., Gozal, D., Iber, C., Kapur, V. K., Marcus, C. L., Mehra, R., Parthasarathy, S., Quan, S. F., et al. (2012) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.2172 · Cited by 5,302
Prospective Study of the Association between Sleep-Disordered Breathing and Hypertension
Peppard, P. E., Young, T., Palta, M., & Skatrud, J. (2000) · New England Journal of Medicine · doi:10.1056/nejm200005113421901 · Cited by 4,973
Marin, J. M., Carrizo, S. J., Vicente, E., & Agusti, A. G. (2005) · The Lancet · doi:10.1016/s0140-6736(05)71141-7 · Cited by 4,678
Using the Berlin Questionnaire To Identify Patients at Risk for the Sleep Apnea Syndrome
Netzer, N. C., Stoohs, R. A., Netzer, C. M., Clark, K., & Strohl, K. P. (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-131-7-199910050-00002 · Cited by 2,973
STOP Questionnaire: A Tool to Screen Patients for Obstructive Sleep Apnea
Chung, F., Yegneswaran, B., Liao, P., Chung, S. A., Vairavanathan, S., Islam, S., Khajehdehi, A., & Shapiro, C. M. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31816d83e4 · Cited by 2,355
Sleep Disordered Breathing and Mortality: Eighteen-Year Follow-up of the Wisconsin Sleep Cohort
(2008) · Sleep · doi:10.5665/sleep/31.8.1071 · Cited by 1,853
Young, T., Evans, L., Finn, L., & Palta, M. (1997) · Sleep · doi:10.1093/sleep/20.9.705 · Cited by 1,765
Collop, N. A., Anderson, W. M., Boehlecke, B., Claman, D., Goldberg, R., Gottlieb, D. J., Hudgel, D., Sateia, M., Schwab, R., & Portable Monitoring Task Force of the American Academy of Sleep Medicine (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27032 · Cited by 1,550
A Randomized Trial of Adenotonsillectomy for Childhood Sleep Apnea
Marcus, C. L., Moore, R. H., Rosen, C. L., Giordani, B., Garetz, S. L., Taylor, H. G., Mitchell, R. B., Amin, R., Katz, E. S., Arens, R., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1215881 · Cited by 1,422
DURÁN, J., ESNAOLA, S., RUBIO, R., & IZTUETA, Á. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.3.2005065 · Cited by 1,407
Obstructive Sleep Apnea Devices for Out-Of-Center (OOC) Testing: Technology Evaluation
Collop, N. A., Tracy, S. L., Kapur, V., Mehra, R., Kuhlmann, D., Fleishman, S. A., & Ojile, J. M. (2011) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.1328 · Cited by 427
Mulgrew, A. T., Fox, N., Ayas, N. T., & Ryan, C. F. (2007) · Annals of Internal Medicine · doi:10.7326/0003-4819-146-3-200702060-00004 · Cited by 368
Rosen, C. L., Auckley, D., Benca, R., Foldvary-Schaefer, N., Iber, C., Kapur, V., Rueschman, M., Zee, P., & Redline, S. (2012) · Sleep · doi:10.5665/sleep.1870 · Cited by 367
A Predictive Morphometric Model for the Obstructive Sleep Apnea Syndrome
Kushida, C. A., Efron, B., & Guilleminault, C. (1997) · Annals of Internal Medicine · doi:10.7326/0003-4819-127-8_part_1-199710150-00001 · Cited by 341
Chai-Coetzer, C. L., Antic, N. A., Rowland, L. S., Catcheside, P. G., Esterman, A., Reed, R. L., Williams, H., Dunn, S., & McEvoy, R. D. (2011) · Thorax · doi:10.1136/thx.2010.152801 · Cited by 233
Noninferiority of Functional Outcome in Ambulatory Management of Obstructive Sleep Apnea
Kuna, S. T., Gurubhagavatula, I., Maislin, G., Hin, S., Hartwig, K. C., McCloskey, S., Hachadoorian, R., Hurley, S., Gupta, R., Staley, B., et al. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201011-1770oc · Cited by 228
Antic, N. A., Buchan, C., Esterman, A., Hensley, M., Naughton, M. T., Rowland, S., Williamson, B., Windler, S., Eckermann, S., & McEvoy, R. D. (2009) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200810-1558oc · Cited by 227
Chai-Coetzer, C. L., Antic, N. A., Rowland, L. S., Reed, R. L., Esterman, A., Catcheside, P. G., Eckermann, S., Vowles, N., Williams, H., Dunn, S., et al. (2013) · JAMA · doi:10.1001/jama.2013.1823 · Cited by 211
A Decision Rule for Diagnostic Testing in Obstructive Sleep Apnea
Tsai, W. H., Remmers, J. E., Brant, R., Flemons, W. W., Davies, J., & Macarthur, C. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200112-110oc · Cited by 189
Pittman, S. D., Ayas, N. T., MacDonald, M. M., Malhotra, A., Fogel, R. B., & White, D. P. (2004) · Sleep · doi:10.1093/sleep/27.5.923 · Cited by 175
Masa, J. F., Corral, J., Pereira, R., Duran-Cantolla, J., Cabello, M., Hernandez-Blasco, L., Monasterio, C., Alonso, A., Chiner, E., Rubio, M., et al. (2011) · Thorax · doi:10.1136/thx.2010.152272 · Cited by 161
Validation of a Portable Monitoring System for the Diagnosis of Obstructive Sleep Apnea Syndrome
Santos-Silva, R., Sartori, D. E., Truksinas, V., Truksinas, E., Alonso, F. F. F. D., Tufik, S., & Bittencourt, L. R. A. (2009) · Sleep · doi:10.1093/sleep/32.5.629 · Cited by 142
Chervin, R. D., Murman, D. L., Malow, B. A., & Totten, V. (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-130-6-199903160-00006 · Cited by 138
Outcomes of Home-Based Diagnosis and Treatment of Obstructive Sleep Apnea
Skomro, R. P., Gjevre, J., Reid, J., McNab, B., Ghosh, S., Stiles, M., Jokic, R., Ward, H., & Cotton, D. (2010) · Chest · doi:10.1378/chest.09-0577 · Cited by 125
Validation of a Self-Applied Unattended Monitor for Sleep Disordered Breathing
Ayappa, I., Norman, R. G., Seelall, V., & Rapoport, D. M. (2008) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27075 · Cited by 125
Deutsch, P. A., Simmons, M. S., & Wallace, J. M. (2006) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.26508 · Cited by 103
CAMPBELL, A. J., & NEILL, A. M. (2011) · Journal of Sleep Research · doi:10.1111/j.1365-2869.2010.00854.x · Cited by 94
West, S. D. (2006) · Thorax · doi:10.1136/thx.2005.046300 · Cited by 93
Sériès, F., Kimoff, R. J., Morrison, D., Leblanc, M. H., Smilovitch, M., Howlett, J., Logan, A. G., Floras, J. S., & Bradley, T. D. (2005) · Chest · doi:10.1378/chest.127.5.1507 · Cited by 83
Respiratory Polygraphy With Actigraphy in the Diagnosis of Sleep Apnea-Hypopnea Syndrome
García-Díaz, E., Quintana-Gallego, E., Ruiz, A., Carmona-Bernal, C., Sánchez-Armengol, Á., Botebol-Benhamou, G., & Capote, F. (2007) · Chest · doi:10.1378/chest.06-1604 · Cited by 80
GANTNER, D., GE, J., LI, L., ANTIC, N., WINDLER, S., WONG, K., HEELEY, E., HUANG, S., CUI, P., ANDERSON, C., et al. (2010) · Respirology · doi:10.1111/j.1440-1843.2010.01797.x · Cited by 64
Effect of an ambulatory diagnostic and treatment programme in patients with sleep apnoea
Andreu, A. L., Chiner, E., Sancho-Chust, J. N., Pastor, E., Llombart, M., Gomez-Merino, E., Senent, C., & Barbé, F. (2012) · European Respiratory Journal · doi:10.1183/09031936.00013311 · Cited by 62
Self-citationYin, M., Miyazaki, S., & Ishikawa, K. (2006) · Otolaryngology–Head and Neck Surgery · doi:10.1016/j.otohns.2005.10.019 · Cited by 60
Oliveira, M. G., Nery, L. E., Santos-Silva, R., Sartori, D. E., Alonso, F. F., Togeiro, S. M., Tufik, S., & Bittencourt, L. (2012) · Sleep Medicine · doi:10.1016/j.sleep.2012.06.011 · Cited by 45
Effectiveness of sequential automatic-manual home respiratory polygraphy scoring
Masa, J. F., Corral, J., Pereira, R., Duran-Cantolla, J., Cabello, M., Hernández-Blasco, L., Monasterio, C., Alonso-Fernandez, A., Chiner, E., Vázquez-Polo, F.-J., et al. (2013) · European Respiratory Journal · doi:10.1183/09031936.00186811 · Cited by 44
McArdle, N., Singh, B., Murphy, M., Gain, K. R., Maguire, C., Mutch, S., & Hillman, D. R. (2010) · Thorax · doi:10.1136/thx.2009.116756 · Cited by 43
Gjevre, J., Taylor-Gjevre, R., Skomro, R., Reid, J., Fenton, M., & Cotton, D. (2011) · Canadian Respiratory Journal · doi:10.1155/2011/408091 · Cited by 40
The Utility of Single-Channel Nasal Airflow Pressure Transducer in the Diagnosis Of OSA at Home
Rofail, L. M., Wong, K. K. H., Unger, G., Marks, G. B., & Grunstein, R. R. (2010) · Sleep · doi:10.1093/sleep/33.8.1097 · Cited by 40
Polese, J. F., Santos-Silva, R., de Oliveira Ferrari, P. M., Sartori, D. E., Tufik, S., & Bittencourt, L. (2013) · Sleep and Breathing · doi:10.1007/s11325-012-0742-y · Cited by 32
Watkins, M. R., Talmage, J. B., Thiese, M. S., Hudson, T. B., & Hegmann, K. T. (2009) · Journal of Occupational & Environmental Medicine · doi:10.1097/jom.0b013e3181b68d52 · Cited by 28
Cited by
Wearable Sleep Technology in Clinical and Research Settings
DE ZAMBOTTI, M., CELLINI, N., GOLDSTONE, A., COLRAIN, I. M., & BAKER, F. C. (2019) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001947 · Cited by 564
International Consensus Statement on Obstructive Sleep Apnea
Chang, J. L., Goldberg, A. N., Alt, J. A., Mohammed, A., Ashbrook, L., Auckley, D., Ayappa, I., Bakhtiar, H., Barrera, J. E., Bartley, B. L., et al. (2023) · International Forum of Allergy & Rhinology · doi:10.1002/alr.23079 · Cited by 350
Senaratna, C. V., Perret, J. L., Matheson, M. C., Lodge, C. J., Lowe, A. J., Cassim, R., Russell, M. A., Burgess, J. A., Hamilton, G. S., & Dharmage, S. C. (2017) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2017.04.001 · Cited by 214
The diagnostic method has a strong influence on classification of obstructive sleep apnea
Escourrou, P., Grote, L., Penzel, T., Mcnicholas, W. T., Verbraecken, J., Tkacova, R., Riha, R. L., Hedner, J., & the ESADA Study Group (2015) · Journal of Sleep Research · doi:10.1111/jsr.12318 · Cited by 114
Abrahamyan, L., Sahakyan, Y., Chung, S., Pechlivanoglou, P., Bielecki, J., Carcone, S. M., Rac, V. E., Fitzpatrick, M., & Krahn, M. (2018) · Sleep and Breathing · doi:10.1007/s11325-017-1615-1 · Cited by 67
Metadata
- Authors
- Corral-Peñafiel, J., Pepin, J.-L., & Barbe, F.
- Venue
- European Respiratory Review
- Publisher
- European Respiratory Society (ERS)
- Published
- 2013-08-30
- Volume
- 22
- Issue
- 129
- Pages
- 312-324
- ISSN
- 0905-9180 (ISSN-L)
- 1600-0617
- OpenAlex
- W2158571582
- Cited by
- 88
- References
- 43
- FWCI
- 4.90
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.