Guidelines and protocols for cardiovascular magnetic resonance in children and adults with congenital heart disease: SCMR expert consensus group on congenital heart disease
Open accessThe DOI matches its Crossref record; 126 of the 126 references it cites were found in a registry or an index.
Abstract
Cardiovascular magnetic resonance (CMR) has taken on an increasingly important role in the diagnostic evaluation and pre-procedural planning for patients with congenital heart disease. This article provides guidelines for the performance of CMR in children and adults with congenital heart disease. The first portion addresses preparation for the examination and safety issues, the second describes the primary techniques used in an examination, and the third provides disease-specific protocols. Variations in practice are highlighted and expert consensus recommendations are provided. Indications and appropriate use criteria for CMR examination are not specifically addressed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
American Heart Association Writing Group on Myocardial Segmentation and Registration for Cardiac Imaging:, Cerqueira, M. D., Weissman, N. J., Dilsizian, V., Jacobs, A. K., Kaul, S., Laskey, W. K., Pennell, D. J., Rumberger, J. A., Ryan, T., et al. (2002) · Circulation · doi:10.1161/hc0402.102975 · Cited by 6,990
Wagner, A., Mahrholdt, H., Holly, T. A., Elliott, M. D., Regenfus, M., Parker, M., Klocke, F. J., Bonow, R. O., Kim, R. J., & Judd, R. M. (2003) · The Lancet · doi:10.1016/s0140-6736(03)12389-6 · Cited by 1,307
Greenwood, J. P., Maredia, N., Younger, J. F., Brown, J. M., Nixon, J., Everett, C. C., Bijsterveld, P., Ridgway, J. P., Radjenovic, A., Dickinson, C. J., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(11)61335-4 · Cited by 1,114
Alfakih, K., Plein, S., Thiele, H., Jones, T., Ridgway, J. P., & Sivananthan, M. U. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10262 · Cited by 732
Kramer, C. M., Barkhausen, J., Flamm, S. D., Kim, R. J., & Nagel, E. (2008) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-10-35 · Cited by 688
Cardiovascular Flow Measurement with Phase-Contrast MR Imaging: Basic Facts and Implementation
Lotz, J., Meier, C., Leppert, A., & Galanski, M. (2002) · RadioGraphics · doi:10.1148/radiographics.22.3.g02ma11651 · Cited by 673
Schwitter, J., Wacker, C. M., van Rossum, A. C., Lombardi, M., Al-Saadi, N., Ahlstrom, H., Dill, T., Larsson, H. B. W., Flamm, S. D., Marquardt, M., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehm617 · Cited by 672
Hudsmith†, L., Petersen†, S., Francis, J., Robson, M., & Neubauer, S. (2005) · Journal of Cardiovascular Magnetic Resonance · doi:10.1080/10976640500295516 · Cited by 627
Babu-Narayan, S. V., Kilner, P. J., Li, W., Moon, J. C., Goktekin, O., Davlouros, P. A., Khan, M., Ho, S. Y., Pennell, D. J., & Gatzoulis, M. A. (2006) · Circulation · doi:10.1161/circulationaha.105.548727 · Cited by 622
Nandalur, K. R., Dwamena, B. A., Choudhri, A. F., Nandalur, M. R., & Carlos, R. C. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.06.030 · Cited by 555
Jahnke, C., Nagel, E., Gebker, R., Kokocinski, T., Kelle, S., Manka, R., Fleck, E., & Paetsch, I. (2007) · Circulation · doi:10.1161/circulationaha.106.652016 · Cited by 514
Theoretical and empirical derivation of cardiovascular allometric relationships in children
Sluysmans, T., & Colan, S. D. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01144.2004 · Cited by 514
Amado, L. C., Gerber, B. L., Gupta, S. N., Rettmann, D. W., Szarf, G., Schock, R., Nasir, K., Kraitchman, D. L., & Lima, J. A. C. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.09.020 · Cited by 508
Levine, G. N., Gomes, A. S., Arai, A. E., Bluemke, D. A., Flamm, S. D., Kanal, E., Manning, W. J., Martin, E. T., Smith, J. M., Wilke, N., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.187256 · Cited by 489
Does Size Matter?: Clinical Applications of Scaling Cardiac Size and Function for Body Size
Dewey, F. E., Rosenthal, D., Murphy, D. J., Froelicher, V. F., & Ashley, E. A. (2008) · Circulation · doi:10.1161/circulationaha.107.736785 · Cited by 467
Kilner, P. J., Geva, T., Kaemmerer, H., Trindade, P. T., Schwitter, J., & Webb, G. D. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehp586 · Cited by 429
Klem, I., Heitner, J. F., Shah, D. J., Sketch, M. H., Behar, V., Weinsaft, J., Cawley, P., Parker, M., Elliott, M., Judd, R. M., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.10.074 · Cited by 415
How We Perform Delayed Enhancement Imaging
Kim, R. J., Shah, D. J., & Judd, R. M. (2003) · Journal of Cardiovascular Magnetic Resonance · doi:10.1081/jcmr-120022267 · Cited by 365
Buechel, E. R. V., Dave, H. H., Kellenberger, C. J., Dodge-Khatami, A., Pretre, R., Berger, F., & Bauersfeld, U. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi581 · Cited by 340
Paetsch, I., Jahnke, C., Wahl, A., Gebker, R., Neuss, M., Fleck, E., & Nagel, E. (2004) · Circulation · doi:10.1161/01.cir.0000138927.00357.fb · Cited by 333
Applications of phase-contrast flow and velocity imaging in cardiovascular MRI
Gatehouse, P. D., Keegan, J., Crowe, L. A., Masood, S., Mohiaddin, R. H., Kreitner, K.-F., & Firmin, D. N. (2005) · European Radiology · doi:10.1007/s00330-005-2829-3 · Cited by 331
Ingkanisorn, W. P., Kwong, R. Y., Bohme, N. S., Geller, N. L., Rhoads, K. L., Dyke, C. K., Paterson, D. I., Syed, M. A., Aletras, A. H., & Arai, A. E. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.11.059 · Cited by 320
Beerbaum, P., Körperich, H., Barth, P., Esdorn, H., Gieseke, J., & Meyer, H. (2001) · Circulation · doi:10.1161/01.cir.103.20.2476 · Cited by 309
Dillman, J. R., Ellis, J. H., Cohan, R. H., Strouse, P. J., & Jan, S. C. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.07.2554 · Cited by 303 · cited 1×
“The incidence of adverse events related to GBCA in both adults and children is very low [14,19-21].”
Mooij, C. F., de Wit, C. J., Graham, D. A., Powell, A. J., & Geva, T. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21407 · Cited by 297
Self-citationBabu-Narayan, S. V., Goktekin, O., Moon, J. C., Broberg, C. S., Pantely, G. A., Pennell, D. J., Gatzoulis, M. A., & Kilner, P. J. (2005) · Circulation · doi:10.1161/01.cir.0000162463.61626.3b · Cited by 293
Incidence of Immediate Gadolinium Contrast Media Reactions
Prince, M. R., Zhang, H., Zou, Z., Staron, R. B., & Brill, P. W. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.10.4885 · Cited by 271
Gelfand, E., Hughes, S., Hauser, T., Yeon, S., Goepfert, L., Kissinger, K., Rofsky, N., & Manning, W. (2006) · Journal of Cardiovascular Magnetic Resonance · doi:10.1080/10976640600604856 · Cited by 265
Wald, R. M., Haber, I., Wald, R., Valente, A. M., Powell, A. J., & Geva, T. (2009) · Circulation · doi:10.1161/circulationaha.108.816546 · Cited by 265
Self-citationCardiovascular Magnetic Resonance Imaging for Valvular Heart Disease: Technique and Validation
Cawley, P. J., Maki, J. H., & Otto, C. M. (2009) · Circulation · doi:10.1161/circulationaha.107.742486 · Cited by 260
Bernstein, M. A., Huston, J., & Ward, H. A. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20698 · Cited by 255
Alfakih, K., Plein, S., Bloomer, T., Jones, T., Ridgway, J., & Sivananthan, M. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10329 · Cited by 246
Geva, T., Greil, G. F., Marshall, A. C., Landzberg, M., & Powell, A. J. (2002) · Circulation · doi:10.1161/01.cir.0000023624.33478.18 · Cited by 245
Self-citationGatehouse, P. D., Rolf, M. P., Graves, M. J., Hofman, M. B., Totman, J., Werner, B., Quest, R. A., Liu, Y., von Spiczak, J., Dieringer, M., et al. (2010) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-12-5 · Cited by 234 · cited 1×
“These include inappropriate setting of the venc, signal loss with complex turbulent flow, partial volume averaging, signal misregistration, and phase offset errors due to eddy currents or uncorrected concomitant gradients [70-72,110,120,121].”
Hundley, W. G., Li, H. F., Willard, J. E., Landau, C., Lange, R. A., Meshack, B. M., Hillis, L. D., & Peshock, R. M. (1995) · Circulation · doi:10.1161/01.cir.92.5.1151 · Cited by 229
Buechel, E. V., Kaiser, T., Jackson, C., Schmitz, A., & Kellenberger, C. J. (2009) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-11-19 · Cited by 228
Gerber, B. L., Raman, S. V., Nayak, K., Epstein, F. H., Ferreira, P., Axel, L., & Kraitchman, D. L. (2008) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-10-18 · Cited by 219
Papavassiliu, T., Kühl, H. P., Schröder, M., Süselbeck, T., Bondarenko, O., Böhm, C. K., Beek, A., Hofman, M. M. B., & van Rossum, A. C. (2005) · Radiology · doi:10.1148/radiol.2353040601 · Cited by 215
Rathod, R. H., Prakash, A., Powell, A. J., & Geva, T. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.12.036 · Cited by 214
Self-citationPowell, A. J., Maier, S. E., Chung, T., & Geva, T. (2000) · Pediatric Cardiology · doi:10.1007/s002469910014 · Cited by 207
Self-citationDulce, M. C., Mostbeck, G. H., O'Sullivan, M., Cheitlin, M., Caputo, G. R., & Higgins, C. B. (1992) · Radiology · doi:10.1148/radiology.185.1.1523315 · Cited by 206
Flow Measurement by Magnetic Resonance: A Unique Asset Worth Optimising
Kilner, P. J., Gatehouse, P. D., & Firmin, D. N. (2007) · Journal of Cardiovascular Magnetic Resonance · doi:10.1080/10976640701465090 · Cited by 205
Quantification of mitral regurgitation by velocity-encoded cine nuclear magnetic resonance imaging
Fujita, N., Chazouilleres, A. F., Hartiala, J. J., O'sullivan, M., Heidenreich, P., Kaplan, J. D., Sakuma, H., Foster, E., Caputo, G. R., & Higgins, C. B. (1994) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)90642-4 · Cited by 198
Grosse-Wortmann, L., Al-Otay, A., & Yoo, S.-J. (2009) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.108.834192 · Cited by 192
Self-citationHundley, W. G., Li, H. F., Lange, R. A., Pfeifer, D. P., Meshack, B. M., Willard, J. E., Landau, C., Willett, D. L., Hillis, L. D., & Peshock, R. M. (1995) · Circulation · doi:10.1161/01.cir.91.12.2955 · Cited by 191
Westenberg, J. J. M., Roes, S. D., Ajmone Marsan, N., Binnendijk, N. M. J., Doornbos, J., Bax, J. J., Reiber, J. H. C., de Roos, A., & van der Geest, R. J. (2008) · Radiology · doi:10.1148/radiol.2492080146 · Cited by 190
Hsu, L., Natanzon, A., Kellman, P., Hirsch, G. A., Aletras, A. H., & Arai, A. E. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20496 · Cited by 186
Sørensen, T. S., Körperich, H., Greil, G. F., Eichhorn, J., Barth, P., Meyer, H., Pedersen, E. M., & Beerbaum, P. (2004) · Circulation · doi:10.1161/01.cir.0000134282.35183.ad · Cited by 181
Self-citationWinter, M. M., Bernink, F. J., Groenink, M., Bouma, B. J., van Dijk, A. P., Helbing, W. A., Tijssen, J. G., & Mulder, B. J. (2008) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-10-40 · Cited by 179
Greil, G. F., Powell, A. J., Gildein, H. P., & Geva, T. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01730-2 · Cited by 179
Self-citationSarikouch, S., Peters, B., Gutberlet, M., Leismann;, B., Kelter-Kloepping, A., Koerperich, H., Kuehne, T., & Beerbaum, P. (2010) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.109.859074 · Cited by 174
MRI Safety Update 2008: Part 2, Screening Patients for MRI
Shellock, F. G., & Spinazzi, A. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.08.1038.2 · Cited by 171
Heart valve disease: investigation by cardiovascular magnetic resonance
Myerson, S. G. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-7 · Cited by 171
Quantitation of cardiac output with velocity-encoded, phase-difference magnetic resonance imaging
Hundley, W. G., Li, H. F., Hillis, L. D., Meshack, B. M., Lange, R. A., Willard, J. E., Landau, C., & Peshock, R. M. (1995) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)80772-3 · Cited by 163
Chernobelsky, A., Shubayev, O., Comeau, C. R., & Wolff, S. D. (2007) · Journal of Cardiovascular Magnetic Resonance · doi:10.1080/10976640601187588 · Cited by 163
Multimodality Noninvasive Imaging for Assessment of Congenital Heart Disease
Prakash, A., Powell, A. J., & Geva, T. (2010) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.109.875021 · Cited by 155
Self-citationHofman, M. B. M., Visser, F. C., van Rossum, A. C., Vink, G. Q. M., Sprenger, M., & Westerhof, N. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330606 · Cited by 152
Luijnenburg, S. E., Robbers‐Visser, D., Moelker, A. D., Vliegen, H. W., Mulder, B. J. M., & Helbing, W. A. (2009) · International journal of cardiac imaging · doi:10.1007/s10554-009-9501-y · Cited by 150
Magnetic resonance volume flow and jet velocity mapping in aortic coarctation
Mohiaddin, R. H., Kilner, P. J., Rees, S., & Longmore, D. B. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90565-i · Cited by 149
Brenner, L. D., Caputo, G. R., Mostbeck, G., Steiman, D. M., Mc, D., Cheitlin, M. D., O'Sullivan, M., & Higgins, C. B. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90384-y · Cited by 146
Sievers, B., Kirchberg, S., Bakan, A., Franken, U., & Trappe, H. (2004) · Journal of Cardiovascular Magnetic Resonance · doi:10.1081/jcmr-120027800 · Cited by 142
Niezen, R. A., Helbing, W. A., van der Wall, E. E., van der Geest, R. J., Rebergen, S. A., & de Roos, A. (1996) · Radiology · doi:10.1148/radiology.201.1.8816534 · Cited by 140
Prasad, S. K., Soukias, N., Hornung, T., KHAN, M. G., Pennell, D. J., Gatzoulis, M. Α., & Mohiaddin, R. H. (2004) · Circulation · doi:10.1161/01.cir.0000107842.29467.c5 · Cited by 138
Caputo, G. R., Kondo, C., Masui, T., Geraci, S. J., Foster, E., O'Sullivan, M. M., & Higgins, C. B. (1991) · Radiology · doi:10.1148/radiology.180.3.1871279 · Cited by 134
Giardini, A., Lovato, L., Donti, A., Formigari, R., Oppido, G., Gargiulo, G., Picchio, F. M., & Fattori, R. (2006) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2006.05.062 · Cited by 134
Anaesthesia considerations for cardiac MRI in infants and small children
Odegard, K. C., DiNardo, J. A., Tsai‐Goodman, B., Powell, A. J., Geva, T., & Laussen, P. C. (2004) · Pediatric Anesthesia · doi:10.1111/j.1460-9592.2004.01221.x · Cited by 133
Self-citationChai, P., & Mohiaddin, R. H. (2005) · Journal of Cardiovascular Magnetic Resonance · doi:10.1081/jcmr-200065639 · Cited by 133
Normal biventricular function, volumes, and mass in children aged 8 to 17 years
Robbers‐Visser, D., Boersma, E., & Helbing, W. A. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21662 · Cited by 118
Prakash, A., Powell, A. J., Krishnamurthy, R., & Geva, T. (2004) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2003.11.045 · Cited by 117
Self-citationBlood Flow Measurement by Magnetic Resonance Imaging in Congenital Heart Disease
Powell, A., & Geva, T. (2000) · Pediatric Cardiology · doi:10.1007/s002469910007 · Cited by 112
Self-citationFratz, S., Schuhbaeck, A., Buchner, C., Busch, R. M., Meierhofer, C., Martinoff, S. A., Hess, J., & Stern, H. C. (2009) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2009.02.030 · Cited by 111
Self-citationImproved Measurement of Pressure Gradients in Aortic Coarctation by Magnetic Resonance Imaging
Oshinski, J. N., Parks, W. J., Markou, C. P., Bergman, H. L., Larson, B. E., Ku, D. N., Mukundan, S., & Pettigrew, R. I. (1996) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(96)00395-6 · Cited by 110
Corrected Tetralogy of Fallot: Delayed Enhancement in Right Ventricular Outflow Tract
Oosterhof, T., Mulder, B. J. M., Vliegen, H. W., & de Roos, A. (2005) · Radiology · doi:10.1148/radiol.2373041324 · Cited by 107
Hsiao, A., Lustig, M. S., Alley, M. T., Murphy, M., Chan, F. P., Herfkens, R. J., & Vasanawala, S. S. (2012) · American Journal of Roentgenology · doi:10.2214/ajr.11.6969 · Cited by 102
Fratz, S., Hess, J., Schwaiger, M., Martinoff, S. A., & Stern, H. C. (2002) · Circulation · doi:10.1161/01.cir.0000029103.26029.1e · Cited by 102
Self-citationTangcharoen, T., Bell, A., Hegde, S., Hussain, T., Beerbaum, P., Schaeffter, T., Razavi, R., Botnar, R. M., & Greil, G. F. (2011) · Radiology · doi:10.1148/radiol.10100828 · Cited by 100
Self-citationBeerbaum, P., Körperich, H., Gieseke, J., Barth, P., Peuster, M., & Meyer, H. (2003) · Circulation · doi:10.1161/01.cir.0000087603.97036.c2 · Cited by 99
Beerbaum, P., Barth, P., Kropf, S., Sarikouch, S., Kelter‐Klöpping, A., Franke, D., Gutberlet, M., & Kühne, T. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21948 · Cited by 95
Blalock, S. E., Banka, P., Geva, T., Powell, A. J., Zhou, J., & Prakash, A. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24050 · Cited by 93
Self-citationPowell, A. J., Tsai‐Goodman, B., Prakash, A., Greil, G. F., & Geva, T. (2003) · The American Journal of Cardiology · doi:10.1016/s0002-9149(03)00417-x · Cited by 89
Self-citationJanik, M. J., Cham, M. D., Ross, M. I., Wang, Y., Codella, N., Min, J. K., Prince, M. R., Manoushagian, S. J., Okin, P. M., Devereux, R. B., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328302ca14 · Cited by 83
Effects of metallic implants on magnetic resonance imaging evaluation of Fontan palliation
Garg, R., Powell, A. J., Sena, L. M., Marshall, A. C., & Geva, T. (2005) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2004.10.053 · Cited by 76
Self-citationMR velocity mapping of tricuspid flow: Correction for through‐plane motion
Kayser, H. W. M., Stoel, B. C., van der Wall, E. E., Geest, R. J. D. V., & Roos, A. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070410 · Cited by 74
Prakash, A., Rathod, R. H., Powell, A. J., McElhinney, D. B., Banka, P., & Geva, T. (2012) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2011.11.040 · Cited by 72
Self-citationRoman, K. S., Kellenberger, C. J., Farooq, S., Macgowan, C. K., Gilday, D. L., & Yoo, S. (2004) · Pediatric Radiology · doi:10.1007/s00247-004-1344-z · Cited by 72
Self-citationThe functional right ventricle and tricuspid regurgitation in Ebstein's anomaly
Fratz, S., Janello, C., Müller, D., Seligmann, M., Meierhofer, C., Schuster, T., Schreiber, C., Martinoff, S. A., Hess, J., Kühn, A., et al. (2012) · International Journal of Cardiology · doi:10.1016/j.ijcard.2011.12.081 · Cited by 70
Self-citationSridharan, S., Derrick, G. P., Deanfield, J. E., & Taylor, A. M. (2006) · Heart · doi:10.1136/hrt.2005.071746 · Cited by 69
Self-citationMR Evaluation of Cardiovascular Physiology in Congenital Heart Disease: Flow and Function
Weber, O. M., & Higgins, C. B. (2006) · Journal of Cardiovascular Magnetic Resonance · doi:10.1080/10976640600740254 · Cited by 69
Risk Factors for Adverse Events During Cardiovascular Magnetic Resonance in Congenital Heart Disease
Dorfman, A. L., Odegard, K. C., Powell, A. J., Laussen, P. C., & Geva, T. (2007) · Journal of Cardiovascular Magnetic Resonance · doi:10.1080/10976640701545305 · Cited by 66
Self-citationThree-dimensional magnetic resonance imaging of congenital cardiac anomalies
Razavi, R., Hill, D., Muthurangu, V., Miquel, M. E., Taylor, A. M., Kozerke, S., & Baker, E. J. (2003) · Cardiology in the Young · doi:10.1017/s1047951103000957 · Cited by 65
Self-citationHarris, M. A., Johnson, T. R., Weinberg, P. M., & Fogel, M. A. (2007) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2006.10.057 · Cited by 64
Fratz, S., Hager, A., Schreiber, C., Schwaiger, M., Hess, J., & Stern, H. C. (2011) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2011.06.021 · Cited by 64
Self-citationMahle, W. T., Parks, W. J., Fyfe, D. A., & Sallee, D. (2003) · The American Journal of Cardiology · doi:10.1016/s0002-9149(03)00746-x · Cited by 63
Kühl, H. P., Papavasiliu, T. S., Beek, A. M., Hofman, M. B. M., Heusen, N. S., & van Rossum, A. C. (2004) · Radiology · doi:10.1148/radiol.2302021120 · Cited by 62
Cardiovascular MR and CT in congenital heart disease
Crean, A. (2007) · Heart · doi:10.1136/hrt.2006.104729 · Cited by 61
Masui, T., Katayama, M., Kobayashi, S., Ito, T., Seguchi, M., Koide, M., Nozaki, A., & Sakahara, H. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200012)12:6<1034::aid-jmri32>3.0.co;2-a · Cited by 60
Buechel, E. R. V., DiBernardo, S., Bauersfeld, U., & Berger, F. F. (2005) · International journal of cardiac imaging · doi:10.1007/s10554-004-4017-y · Cited by 59
van der Hulst, A. E., Westenberg, J. J. M., Kroft, L. J. M., Bax, J. J., Blom, N. A., de Roos, A., & Roest, A. A. W. (2010) · Radiology · doi:10.1148/radiol.10092269 · Cited by 59
Brandts, A., Bertini, M., van Dijk, E., Delgado, V., Marsan, N. A., van der Geest, R. J., Siebelink, H. J., Roos, A., Bax, J. J., & Westenberg, J. J. M. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22424 · Cited by 57
Leiner, T., & Kucharczyk, W. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22021 · Cited by 57
Beerbaum, P., Sarikouch, S., Laser, K., Greil, G., Burchert, W., & Körperich, H. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21655 · Cited by 56
Self-citationMRI of Patients With Cardiac Pacemakers: A Review of the Medical Literature
Zikria, J. F., Machnicki, S. C., Rhim, E. S., Bhatti, T. K., & Graham, R. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.10.4239 · Cited by 56
Feasibility of perfusion cardiovascular magnetic resonance in paediatric patients
Buechel, E. R. V., Balmer, C., Bauersfeld, U., Kellenberger, C. J., & Schwitter, J. (2009) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-11-51 · Cited by 55
Fenchel, M. C., Greil, G. F., Martirosian, P., Krämer, U., Schick, F., Claussen, C. D., Sieverding, L., & Miller, S. (2006) · Pediatric Radiology · doi:10.1007/s00247-006-0314-z · Cited by 53
Self-citationLey, S., Eichhorn, J., Ley‐Zaporozhan, J., Ulmer, H. E., Schenk, J., Kauczor, H., & Arnold, R. (2007) · Pediatric Radiology · doi:10.1007/s00247-007-0414-4 · Cited by 53
Bailliard, F., Hughes, M. L., & Taylor, A. M. (2008) · European Journal of Radiology · doi:10.1016/j.ejrad.2008.05.016 · Cited by 52
Self-citationBaseline correction of phase-contrast images in congenital cardiovascular magnetic resonance
Holland, B. J., Printz, B. F., & Lai, W. W. (2010) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-12-11 · Cited by 51
Liang, X., Lam, W., Cheung, E., Wu, A., Wong, S. J., & Cheung, Y. (2010) · Clinical Cardiology · doi:10.1002/clc.20711 · Cited by 50
Manso, B., Castellote, A., Dos, L., & Casaldáliga, J. (2010) · Cardiology in the Young · doi:10.1017/s1047951109990503 · Cited by 50
Fogel, M. A., Pawlowski, T. W., Harris, M. A., Whitehead, K. K., Keller, M. S., Wilson, J., tipton, D. B., & Harris, C. (2011) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2011.03.008 · Cited by 49
Plathow, C., Ley, S., Zaporozhan, J., Schöbinger, M., Grünig, E., Puderbach, M., Eichinger, M., Meinzer, H.-P., ZUNA, I., & Kauczor, H. (2005) · European Radiology · doi:10.1007/s00330-005-2795-9 · Cited by 49
Fratz, S., Hess, J., Schuhbaeck, A., Buchner, C., Hendrich, E., Martinoff, S. A., & Stern, H. C. (2008) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-10-46 · Cited by 49
Self-citationKirschbaum, S. W., Baks, T., Gronenschild, E. H. B. M., Aben, J., Weustink, A. C., Wielopolski, P. A., Krestin, G. P., de Feyter, P. J., & van Geuns, R. (2007) · Investigative Radiology · doi:10.1097/rli.0b013e318154b1dc · Cited by 49
Fratz, S., Hauser, M., Bengel, F. M., Hager, A., Kaemmerer, H., Schwaiger, M., Hess, J., & Stern, H. C. (2006) · Heart · doi:10.1136/hrt.2005.086579 · Cited by 49
Self-citationJohansson, B. H., Babu‐Narayan, S. V., & Kilner, P. J. (2009) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-11-1 · Cited by 46
Su, J. T., Chung, T., Muthupillai, R., Pignatelli, R. H., Kung, G. C., Diaz, L. K., Vick, G. W., & Kovalchin, J. P. (2005) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2004.10.051 · Cited by 41
Self-citationKutty, S., Whitehead, K. K., Natarajan, S. S., Harris, M. A., Wernovsky, G., & Fogel, M. A. (2009) · Pediatric Cardiology · doi:10.1007/s00246-009-9490-6 · Cited by 40
How We Perform Myocardial Perfusion With Cardiovascular Magnetic Resonance
Gebker, R., Schwitter, J., Fleck, E., & Nagel, E. C. (2007) · Journal of Cardiovascular Magnetic Resonance · doi:10.1080/10976640600897286 · Cited by 40
Robinson, J. D., del Nido, P. J., Geggel, R. L., Pérez‐Atayde, A. R., Lock, J. E., & Powell, A. J. (2010) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2010.03.045 · Cited by 39
Self-citationJuvenile and Adult Congenital Heart Disease: Time-resolved 3D Contrast-enhanced MR Angiography
Fenchel, M. C., Saleh, R. S., Dinh, H. H., Lee, M. H., Nael, K., Krishnam, M. S., Ruehm, S. G., Miller, S., CHILD, J. S., & Finn, J. P. (2007) · Radiology · doi:10.1148/radiol.2442061045 · Cited by 39
Evaluation of Adult Congenital Heart Disease by Cardiac Magnetic Resonance Imaging
Marcotte, F., Poirier, N. C., Pressacco, J., Paquet, E., Mercier, L., Dore, A., Ibrahim, R., & Khairy, P. (2009) · Congenital Heart Disease · doi:10.1111/j.1747-0803.2009.00313.x · Cited by 35
Improved accuracy in flow mapping of congenital heart disease using stationary phantom technique
Miller, T. A., Landes, A., & Moran, A. M. (2009) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-11-52 · Cited by 30
Cardiovascular Magnetic Resonance Imaging for Intensive Care Infants: Safe and Effective?
Sarikouch, S., Schaeffler, R., Körperich, H., Dongas, A., Haas, N. A., & Beerbaum, P. (2008) · Pediatric Cardiology · doi:10.1007/s00246-008-9295-z · Cited by 29
Holmqvist, C., Óskarsson, G., Ståhlberg, F., Thilén, U., Björkhem, G., & Laurin, S. (1999) · The American Journal of Cardiology · doi:10.1016/s0002-9149(98)01060-1 · Cited by 25
Taylor, A. M., Dymarkowski, S., Meerleer, K. D., Hamaekers, P., Gewillig, M. H. M. L., Mertens, L., & Bogaert, J. G. (2005) · Journal of Cardiovascular Magnetic Resonance · doi:10.1080/10976640500283421 · Cited by 21
Self-citationPrakash, A., Garg, R., Marcus, E. N., Reynolds, G., Geva, T., & Powell, A. J. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20654 · Cited by 18
Self-citation
Cited by
Recommendations for Noninvasive Evaluation of Native Valvular Regurgitation
Zoghbi, W. A., Adams, D., Bonow, R. O., Enriquez-Sarano, M., Foster, E., Grayburn, P. A., Hahn, R. T., Han, Y., Hung, J., Lang, R. M., et al. (2017) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2017.01.007 · Cited by 3,556
Standardized cardiovascular magnetic resonance imaging (CMR) protocols: 2020 update
Kramer, C. M., Barkhausen, J., Bucciarelli-Ducci, C., Flamm, S. D., Kim, R. J., & Nagel, E. (2020) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-020-00607-1 · Cited by 1,245
Standardized cardiovascular magnetic resonance (CMR) protocols 2013 update
Kramer, C. M., Barkhausen, J., Flamm, S. D., Kim, R. J., & Nagel, E. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-91 · Cited by 734
4D Flow cardiovascular magnetic resonance consensus statement: 2023 update
Bissell, M. M., Raimondi, F., Ait Ali, L., Allen, B. D., Barker, A. J., Bolger, A., Burris, N., Carhäll, C.-J., Collins, J. D., Ebbers, T., et al. (2023) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-023-00942-z · Cited by 296
Zoghbi, W. A., Jone, P.-N., Chamsi-Pasha, M. A., Chen, T., Collins, K. A., Desai, M. Y., Grayburn, P., Groves, D. W., Hahn, R. T., Little, S. H., et al. (2024) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2023.10.004 · Cited by 197
Metadata
- Authors
- Fratz, S., Chung, T., Greil, G. F., Samyn, M. M., Taylor, A. M., Valsangiacomo Buechel, E. R., Yoo, S.-J., & Powell, A. J.
- Venue
- Journal of Cardiovascular Magnetic Resonance
- Publisher
- Elsevier BV
- Published
- 2013-01
- Volume
- 15
- Issue
- 1
- Pages
- 51
- ISSN
- 1097-6647 (ISSN-L)
- OpenAlex
- W2031563096
- Cited by
- 507
- References
- 126
- FWCI
- 15.57
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.