Clinical review: Respiratory monitoring in the ICU - a consensus of 16
Open accessThe DOI matches its Crossref record; 100 of the 100 references it cites were found in a registry or an index.
Abstract
Monitoring plays an important role in the current management of patients with acute respiratory failure but sometimes lacks definition regarding which 'signals' and 'derived variables' should be prioritized as well as specifics related to timing (continuous versus intermittent) and modality (static versus dynamic). Many new techniques of respiratory monitoring have been made available for clinical use recently, but their place is not always well defined. Appropriate use of available monitoring techniques and correct interpretation of the data provided can help improve our understanding of the disease processes involved and the effects of clinical interventions. In this consensus paper, we provide an overview of the important parameters that can and should be monitored in the critically ill patient with respiratory failure and discuss how the data provided can impact on clinical management.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bernard, G. R., Artigas, A., Brigham, K. L., Carlet, J., Falke, K., Hudson, L., Lamy, M., Legall, J. R., Morris, A., & Spragg, R. (1994) · American journal of respiratory and critical care medicine · doi:10.1164/ajrccm.149.3.7509706 · Cited by 6,746 · cited 1×
“Blood gases Th e PaO2/inspired fraction of oxygen (PaO2/FiO2) ratio is still the most frequently used variable for evaluating the severity of lung failure and is included in the current defi nition of acute lung injury/ARDS [20].”
MethodEsteban, A. (2002) · JAMA · doi:10.1001/jama.287.3.345 · Cited by 1,779 · cited 3×
“Finally, tracheostomy is commonly imple mented as part of the management of these neurological patients, but the technique of choice and timing are controversial [109].”
BackgroundMethodMechanical ventilation guided by esophageal pressure in acute lung injury.
Talmor, D., Sarge, T., Malhotra, A., O'Donnell, C. R., Ritz, R., Lisbon, A., Novack, V., & Loring, S. H. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0708638 · Cited by 1,149 · cited 1×
“ΔPaw = ΔPEl,lung+ ΔPes = ΔVol × El,lung + ΔVol × Elcw = ΔVol × (El,lung + Elcw) PEl,lung is the real eff ector of lung volume changes and of potential ventilator-induced lung injury (VILI) and is of major importance in the setting of mechanical ventilation [68].”
BackgroundPatient-ventilator asynchrony during assisted mechanical ventilation
Thille, A. W., Rodriguez, P., Cabello, B., Lellouche, F., & Brochard, L. (2006) · Intensive Care Medicine · doi:10.1007/s00134-006-0301-8 · Cited by 930 · cited 2×
“Recognizing dyssynchrony is important because it can indicate dynamic hyperinfl ation and may lead to excessive ventilatory assistance [55] and induce delays in weaning from mechanical ventilation [56] and severe sleep disruption [57].”
BackgroundSelf-citationPulmonary Dead-Space Fraction as a Risk Factor for Death in the Acute Respiratory Distress Syndrome
Nuckton, T. J., Alonso, J. A., Kallet, R. H., Daniel, B. M., Pittet, J.-F., Eisner, M. D., & Matthay, M. A. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012835 · Cited by 892
Lung Stress and Strain during Mechanical Ventilation for Acute Respiratory Distress Syndrome
Chiumello, D., Carlesso, E., Cadringher, P., Caironi, P., Valenza, F., Polli, F., Tallarini, F., Cozzi, P., Cressoni, M., Colombo, A., et al. (2008) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200710-1589oc · Cited by 777 · cited 1×
“Chiumello and colleagues [70] recently explored the concept of specifi c elastance, which refl ects the intrinsic elastic properties of the lung parenchyma and which relates stress (transpulmonary pressure) and strain (change in volume relative to functional residual capacity (FRC)).”
BackgroundSelf-citationAntonelli, M., Conti, G., Moro, M., Esquinas, A., Gonzalez-Diaz, G., Confalonieri, M., Pelaia, P., Principi, T., Gregoretti, C., Beltrame, F., et al. (2001) · Intensive Care Medicine · doi:10.1007/s00134-001-1114-4 · Cited by 757 · cited 4×
“Competing interests Over the last fi ve years, L Brochard’s laboratory has received research grants for specifi c research projects from the following companies: Dräger (SmartCare; Lübeck, Germany), Maquet (NAVA; Rastatt, Germany), Covidien (PAV+; Dublin, Ireland), General Electric Company (FRC; Fairfi eld, CT, USA),…”
BackgroundInfluentialBedside Ultrasound Assessment of Positive End-Expiratory Pressure–induced Lung Recruitment
Bouhemad, B., Brisson, H., Le-Guen, M., Arbelot, C., Lu, Q., & Rouby, J.-J. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201003-0369oc · Cited by 735
Rapidly Progressive Diaphragmatic Weakness and Injury during Mechanical Ventilation in Humans
Jaber, S., Petrof, B. J., Jung, B., Chanques, G., Berthet, J.-P., Rabuel, C., Bouyabrine, H., Courouble, P., Koechlin-Ramonatxo, C., Sebbane, M., et al. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201004-0670oc · Cited by 709 · cited 1×
“Diaphragmatic function can be altered early and is related to the duration of mechanical ventilation [50].”
BackgroundSelf-citationPrognostic Value of Extravascular Lung Water in Critically Ill Patients
Sakka, S. G., Klein, M., Reinhart, K., & Meier‐Hellmann, A. (2002) · CHEST Journal · doi:10.1378/chest.122.6.2080 · Cited by 672 · cited 1×
“Extravascular lung water Extravascular lung water (EVLW) is a quantitative measure of pulmonary edema and is correlated, in multiple patient populations, to mortality [32].”
BackgroundLung Structure and Function in Different Stages of Severe Adult Respiratory Distress Syndrome
Gattinoni, L. (1994) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1994.03510460064035 · Cited by 589
Self-citationRecruitment and Derecruitment during Acute Respiratory Failure: A Clinical Study
CROTTI, S., MASCHERONI, D., CAIRONI, P., PELOSI, P., RONZONI, G., MONDINO, M., MARINI, J. J., & GATTINONI, L. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.1.2007011 · Cited by 575 · cited 1×
“Second, recruitment takes place throughout the P/V curve [41,42], and recruitment and overdistension can occur at the same time.”
BackgroundSelf-citationAcute Left Ventricular Dysfunction during Unsuccessful Weaning from Mechanical Ventilation
Lemaire, F., Teboul, J.-L., Cinotti, L., Giotto, G., Abrouk, F., Steg, G., Macquin-Mavier, I., & Zapol, W. M. (1988) · Anesthesiology · doi:10.1097/00000542-198808000-00004 · Cited by 570 · cited 1×
“Decreased pleural pressure has been shown to be associated with cardiovascular failure during weaning [74], possibly because of increased transdiaphrag matic pressure and right heart overload [75].”
BackgroundMalbrain, M. L. N. G., Chiumello, D., Pelosi, P., Wilmer, A., Brienza, N., Malcangi, V., Bihari, D., Innes, R., Cohen, J., Singer, P., et al. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2169-9 · Cited by 565 · cited 1×
“IAP can be assessed fairly simply by using a bladder catheter [76], and given that high IAPs can have conse quences in terms of diagnosis and management, more regular measurement of IAP is recommended.”
BackgroundSelf-citationRecruitment and Derecruitment During Acute Respiratory Failure: An Experimental Study
PELOSI, P., GOLDNER, M., McKIBBEN, A., ADAMS, A., ECCHER, G., CAIRONI, P., LOSAPPIO, S., GATTINONI, L., & MARINI, J. J. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.1.2007010 · Cited by 524 · cited 2×
“CT images can be used to compute average lung density and quantitate the respective amounts of air and tissue, but this approach is currently restricted to research [42,89].”
BackgroundMethodSelf-citationCosta, E. L. V., Borges, J. B., Melo, A., Suarez-Sipmann, F., Toufen, C., Bohm, S. H., & Amato, M. B. P. (2009) · Intensive Care Medicine · doi:10.1007/s00134-009-1447-y · Cited by 506 · cited 2×
“Costa and colleagues [93] introduced an algorithm for estimating recruitable alveolar collapse by using EIT.”
BackgroundIdentification of patients with acute lung injury. Predictors of mortality.
Doyle, R. L., Szaflarski, N., Modin, G. W., Wiener-Kronish, J. P., & Matthay, M. A. (1995) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.152.6.8520742 · Cited by 498 · cited 1×
“PaCO2-related variables are tightly correlated to outcome [28] and to lung structural changes [29] sometimes better than oxygen-related variables (such as shunt fraction) [30,31].”
BackgroundTotal Respiratory Pressure-Volume Curves in the Adult Respiratory Distress Syndrome
Matamis, D., Lemaire, F., Harf, A., Brun-Buisson, C., Ansquer, J. C., & Atlan, G. (1984) · Chest · doi:10.1378/chest.86.1.58 · Cited by 475 · cited 3×
“Th e accent has often been placed on identifi cation of the lower (LIP) [39] and upper (UIP) [40] infl ection points on the P/V curve, but this approach has limitations.”
BackgroundMoller, J. T., Johannessen, N. W., Espersen, K., Ravlo, O., Pedersen, B. D., Jensen, P. F., Rasmussen, N. H., Rasmussen, L. S., Pedersen, T., Cooper, J. B., et al. (1993) · Anesthesiology · doi:10.1097/00000542-199303000-00007 · Cited by 435 · cited 1×
“In a randomized controlled trial in more than 20,000 surgical patients [5], pulse oximetry was not associated with decreased postoperative complications or mortality, but 80% of the anesthesiologists felt more secure when a pulse oximeter was used! Transcutaneous partial pressure of carbon dioxide (PCO2) monitors have…”
BackgroundVentilation with end-expiratory pressure in acute lung disease
Falke, K. J., Pontoppidan, H., Kumar, A., Leith, D. E., Geffin, B., & Laver, M. B. (1972) · Journal of Clinical Investigation · doi:10.1172/jci107042 · Cited by 435
Comparison of assisted ventilator modes on triggering, patient effort, and dyspnea.
Leung, P., Jubran, A., & Tobin, M. J. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.155.6.9196100 · Cited by 420 · cited 1×
“Excessive levels of pressure support may result in ineff ective triggering because they are associated with long inspiratory times and intrinsic PEEP [54], and insuffi cient assistance (for example, because of a short inspiratory time during assist/control ventilation) can also result in dyssynchrony.”
BackgroundSelf-citationWillson, D. F. (2005) · JAMA · doi:10.1001/jama.293.4.470 · Cited by 420
Clinical review: Update on hemodynamic monitoring - a consensus of 16
Vincent, J.-L., Rhodes, A., Perel, A., Martin, G. S., Rocca, G., Vallet, B., Pinsky, M. R., Hofer, C. K., Teboul, J.-L., de Boode, W.-P., et al. (2011) · Critical Care · doi:10.1186/cc10291 · Cited by 419 · cited 1×
“Hemodynamic monitoring Th e use of hemodynamic monitoring in the unstable critically ill patient was reviewed recently [96].”
BackgroundSelf-citationFeiner, J. R., Severinghaus, J. W., & Bickler, P. E. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000285988.35174.d9 · Cited by 400 · cited 1×
“Nail polish may aff ect the measure ment by about 2% (not really clinically relevant) [2], and pulse oximetry can slightly underestimate arterial oxygen saturation (SaO2) in patients with darkly pigmented skin [3].”
BackgroundMONCHI, M., BELLENFANT, F., CARIOU, A., JOLY, L.-M., THEBERT, D., LAURENT, I., DHAINAUT, J.-F., & BRUNET, F. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.4.9802009 · Cited by 393 · cited 1×
“PaCO2-related variables are tightly correlated to outcome [28] and to lung structural changes [29] sometimes better than oxygen-related variables (such as shunt fraction) [30,31].”
BackgroundUltrasound assessment of antibiotic-induced pulmonary reaeration in ventilator-associated pneumonia*
Bouhemad, B., Liu, Z., Arbelot, C., Zhang, M., Ferarri, F., Guen, M. L., Girard, M., Lü, Q., & Rouby, J. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181b08cdb · Cited by 386 · cited 1×
“Recently, it was shown that lung ultrasonography can be used to estimate alveolar reaeration in patients treated for ventilator-associated pneumonia [87] and to estimate PEEP-induced lung recruitment [88].”
BackgroundJONSON, B., RICHARD, J.-C., STRAUS, C., MANCEBO, J., LEMAIRE, F., & BROCHARD, L. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.4.9801088 · Cited by 385
Self-citationPredictors of Successful Extubation in Neurosurgical Patients
NAMEN, A. M., WESLEY ELY, E., TATTER, S. B., DOUGLAS CASE, L., LUCIA, M. A., SMITH, A., LANDRY, S., WILSON, J. A., GLAZIER, S. S., BRANCH, C. L., et al. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.3.2003060 · Cited by 355 · cited 1×
“conscious ness, typical weaning and liberation techniques used in medical-surgical ICU patients may not apply to this group [109,112].”
MethodVignaux, L., Vargas, F., Roeseler, J., Tassaux, D., Thille, A. W., Kossowsky, M. P., Brochard, L., & Jolliet, P. (2009) · Intensive Care Medicine · doi:10.1007/s00134-009-1416-5 · Cited by 353 · cited 1×
“Patient-ventilator asynchrony occurs in almost one half of patients and may be related largely to leaks [104].”
BackgroundSelf-citationTitration of tidal volume and induced hypercapnia in acute respiratory distress syndrome.
Roupie, E., Dambrosio, M., Servillo, G., Mentec, H., el Atrous, S., Beydon, L., Brun-Buisson, C., Lemaire, F., & Brochard, L. (1995) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.152.1.7599810 · Cited by 327 · cited 3×
“Th e accent has often been placed on identifi cation of the lower (LIP) [39] and upper (UIP) [40] infl ection points on the P/V curve, but this approach has limitations.”
BackgroundSelf-citationEffect of Ventilator Mode on Sleep Quality in Critically Ill Patients
Parthasarathy, S., & Tobin, M. J. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200209-999oc · Cited by 324
Accuracy of pulse oximetry in the intensive care unit
Louw, A., Cracco, C., Cerf, C., Harf, A., Duvaldestin, P., Lemaire, F., & Brochard, L. (2001) · Intensive Care Medicine · doi:10.1007/s001340101064 · Cited by 308 · cited 1×
“monitoring Pulse oximetry is widely used in anesthesiology and intensive care and, in intensive care unit (ICU) patients, has a bias of less than 1% and a good to moderate precision [1]; accuracy decreases in hypoxemia (oxygen saturation as measured by pulse oximetry, or SpO2, of less than 90%).”
Self-citationA Computed Tomography Scan Assessment of Regional Lung Volume in Acute Lung Injury
PUYBASSET, L., CLUZEL, P., CHAO, N., SLUTSKY, A. S., CORIAT, P., ROUBY, J.-J., & the CT Scan ARDS Study Group (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.5.9802003 · Cited by 289 · cited 1×
“CT images can be used to compute average lung density and quantitate the respective amounts of air and tissue, but this approach is currently restricted to research [42,89].”
MethodThille, A. W., Cabello, B., Galia, F., Lyazidi, A., & Brochard, L. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1121-9 · Cited by 288
Self-citationARDSnet Ventilatory Protocol and Alveolar Hyperinflation: Role of Positive End-Expiratory Pressure
Grasso, S., Stripoli, T., De Michele, M., Bruno, F., Moschetta, M., Angelelli, G., Munno, I., Ruggiero, V., Anaclerio, R., Cafarelli, A., et al. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200702-193oc · Cited by 284 · cited 1×
“A stress index of less than 1 may suggest a need to increase PEEP; a stress index of greater than 1 may suggest a need to reduce VT [47].”
BackgroundGrasso, S., Terragni, P., Mascia, L., Fanelli, V., Quintel, M., Herrmann, P., Hedenstierna, G., Slutsky, A. S., & Ranieri, V. M. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000120059.94009.ad · Cited by 282 · cited 1×
“During constant fl ow insuffl ations, a stress index (Figure 2) can be calculated from the shape of the airway pressure-versus-time curve (which is essentially the opposite of the P/V curve since during constant fl ow time equals volume) [46].”
BackgroundSelf-citationJUBRAN, A., MATHRU, M., DRIES, D., & TOBIN, M. J. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.6.9804056 · Cited by 276 · cited 1×
“During the weaning process, a reduction in SvO2 may be expected as spontaneous breathing represents a form of exercise, but a decrease in SvO2 may refl ect the inability of the heart to face the increased oxygen demand, especially if arterial hypertension is present [97].”
BackgroundSelf-citationNon-neurologic organ dysfunction in severe traumatic brain injury*
Zygun, D. A., Kortbeek, J. B., Fick, G. H., Laupland, K. B., & Doig, C. J. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000155911.01844.54 · Cited by 266 · cited 1×
“Outcomes of critically ill neurological patients are driven mainly by the underlying neurological pathology [108,109], and the infl uence of extracerebral organ dysfunction and ventilatory management on outcomes in this group of patients is not well established [110].”
BackgroundManagement and outcome of mechanically ventilated neurologic patients*
Pelosi, P., Ferguson, N. D., Frutos-Vivar, F., Anzueto, A., Putensen, C., Raymondos, K., Apezteguia, C., Desmery, P., Hurtado, J., Abroug, F., et al. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e31821209a8 · Cited by 257 · cited 1×
“Respiratory monitoring in the neurological patient Neurological dysfunction is one of the most frequent reasons for initiating mechanical ventilation [107].”
BackgroundSelf-citationMeta-analysis of arterial oxygen saturation monitoring by pulse oximetry in adults
Jensen, L. A., Onyskiw, J. E., & Prasad, N. G. N. (1998) · Heart & Lung · doi:10.1016/s0147-9563(98)90086-3 · Cited by 243 · cited 1×
“Th e type of probe can make a diff erence, and accuracy is usually better for fi nger than for earlobe probes [4].”
BackgroundSassoon, C. S. H., Light, R. W., Lodia, R., Sieck, G. C., & Mahutte, C. K. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/143.3.469 · Cited by 238 · cited 1×
“Normal values for the pressuretime product range between 60 and 150 cm H2O/second per minute [67].”
BackgroundMAGGIORE, S. M., JONSON, B., RICHARD, J.-C., JABER, S., LEMAIRE, F., & BROCHARD, L. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.5.2006071 · Cited by 237 · cited 1×
“Quantifi cation of recruitment requires multiple P/V curves [45], and, although P/V curves are now more frequently available on commercial ventilators, the lack of an estimate of recruitment still limits clinical usefulness.”
BackgroundSelf-citationHyperventilation in Head Injury
Stocchetti, N., Maas, A. I. R., Chieregato, A., & van der Plas, A. A. (2005) · Chest · doi:10.1378/chest.127.5.1812 · Cited by 235 · cited 1×
“Hyper ventilation should, therefore, be used only for short-term management of raised ICP and only in patients with life-threatening intracranial hypertension [115,116].”
BackgroundMonnet, X., Anguel, N., Osman, D., Hamzaoui, O., Richard, C., & Teboul, J.-L. (2007) · Intensive Care Medicine · doi:10.1007/s00134-006-0498-6 · Cited by 227 · cited 2×
“Although repeated measures could be used to assess response to interventions [35], it is unclear how fast the response time is and whether this technique can be used as a tool to guide therapy.”
MethodBellani, G., Guerra, L., Musch, G., Zanella, A., Patroniti, N., Mauri, T., Messa, C., & Pesenti, A. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201008-1318oc · Cited by 217 · cited 1×
“Th e concept that the risk of VILI can be related to the ratio between VT and EELV has been suggested by positron emission tomography studies in patients with ARDS [71].”
BackgroundSelf-citationCaricato, A., Conti, G., Corte, F. D., Mancino, A., Santilli, F., Sandroni, C., Proietti, R., & Antonelli, M. (2005) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/01.ta.0000152806.19198.db · Cited by 202 · cited 1×
“Moderate levels of PEEP (for example, less than 15 cm H2O) can be safely used in patients with cerebral lesions, mainly in those with low pulmonary compliance [117].”
BackgroundRaurich, J. M., Vilar, M., Colomar, A., Ibáñez, J., Ayestarán, I., Pérez‐Bárcena, J., & Llompart‐Pou, J. A. (2010) · Respiratory Care · doi:10.4187/respcare.10550282 · Cited by 201 · cited 1×
“Several authors [9,10] have demonstrated that increased Vdphys values are independently associated with an increased risk of death in these patients.”
BackgroundImpact of Expiratory Trigger Setting on Delayed Cycling and Inspiratory Muscle Workload
Tassaux, D., Gainnier, M., Battisti, A., & Jolliet, P. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200407-880oc · Cited by 196 · cited 1×
“Electromyo graphy can also be of use in determining the presence of dyssynchrony but is rather complex for clinical use [58].”
BackgroundJaber, S., Jung, B., Matecki, S., & Petrof, B. J. (2011) · Critical Care · doi:10.1186/cc10023 · Cited by 195 · cited 1×
“Diaphragmatic function Mechanical ventilation has been associated with ventilator-induced diaphragmatic dysfunction [49].”
BackgroundSelf-citationOleg??rd, C., S??ndergaard, S., Houltz, E., Lundin, S., & Stenqvist, O. (2005) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000165823.90368.55 · Cited by 184 · cited 1×
“Olegard and colleagues [78] reported that, by changing the FiO2 abruptly by as little as 0.”
BackgroundSelf-citationDellamonica, J., Lerolle, N., Sargentini, C., Beduneau, G., Di Marco, F., Mercat, A., Richard, J. C. M., Diehl, J. L., Mancebo, J., Rouby, J. J., et al. (2011) · Intensive Care Medicine · doi:10.1007/s00134-011-2333-y · Cited by 181 · cited 1×
“If application of PEEP leads to a higher EELV, this method can be used to estimate alveolar recruitment at the bedside [84].”
MethodSelf-citationNava, S., Bruschi, C., Fracchia, C., Braschi, A., & Rubini, F. (1997) · European Respiratory Journal · doi:10.1183/09031936.97.10010177 · Cited by 171 · cited 1×
“Since it is independent from the ability of the patient to generate volume, the pressuretime product is relevant in situations in which there is a disconnection between eff ort and volume (for example, during asynchrony) [66].”
BackgroundRespiratory muscle oxygen consumption estimated by the diaphragm pressure-time index
Field, S., Sanci, S., & Grassino, A. (1984) · Journal of Applied Physiology · doi:10.1152/jappl.1984.57.1.44 · Cited by 170 · cited 1×
“Th e pressure-time product is asso ciated with oxygen consumption by the respiratory muscles [65] and could be considered a surrogate to quantify the metabolic expense of respiratory eff ort.”
BackgroundA Simple Automated Method for Measuring Pressure–Volume Curves during Mechanical Ventilation
LU, Q., VIEIRA, S. R. R., RICHECOEUR, J., PUYBASSET, L., KALFON, P., CORIAT, P., & ROUBY, J.-J. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.1.9802082 · Cited by 169 · cited 1×
“Study of pressure/volume (P/V) curves requires insuffl ations at very low fl ow to avoid the infl uence of the resistive components [36-38].”
BackgroundP0.1 is a useful parameter in setting the level of pressure support ventilation
Alberti, A., Gallo, F., Fongaro, A., Valenti, S., & Rossi, A. (1995) · Intensive Care Medicine · doi:10.1007/bf01700158 · Cited by 164 · cited 1×
“1, now automatically provided on ventilators, may be useful to assess the patient’s response to titration of ventilator settings (that is, fl ow rate, PEEP, and so on) and could be used as a surro gate of WOB to help titrate pressure support or external PEEP in cases of intrinsic PEEP [60,64].”
MethodEberhard, P. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000278642.16117.f8 · Cited by 161
Echocardiography: a help in the weaning process
Caille, V., Amiel, J.-B., Charron, C., Belliard, G., Vieillard‐Baron, A., & Vignon, P. (2010) · Critical Care · doi:10.1186/cc9076 · Cited by 159 · cited 5×
“Echo can help to estimate pulmonary artery occlusion pressure elevation during SBT.”
BackgroundInfluentialSelf-citationVariability of indices of hypoxemia in adult respiratory distress syndrome
Gowda, M. S., & Klocke, R. A. (1997) · Critical Care Medicine · doi:10.1097/00003246-199701000-00010 · Cited by 159 · cited 1×
“Th e PaO2/FiO2 ratio is often a curvilinear (U-shaped) relationship, being at its lowest for moderate ranges of FiO2, depending on the shunt level, the hemoglobin value, and the arteriovenous diff erence in O2 content [21-23].”
BackgroundDessap, A. M., Boissier, F., Rusel, L., Carreira, S., Campo, F. R., Lemaire, F., & Brochard, L. J. (2010) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181eaa9c8 · Cited by 156
Self-citationCabello, B., & Mancebo, J. (2006) · Intensive Care Medicine · doi:10.1007/s00134-006-0278-3 · Cited by 155 · cited 1×
“It represents the energy associated with a given VT at a given pressure (spontaneous, mechanical, or both) [59].”
BackgroundSelf-citationB-type natriuretic peptide and weaning from mechanical ventilation
Dessap, A. M., de Prost, N., Girou, E., Braconnier, F., Lemaire, F., Brun‐Buisson, C., & Brochard, L. J. (2006) · Intensive Care Medicine · doi:10.1007/s00134-006-0339-7 · Cited by 149 · cited 1×
“Cardiac biomarkers, like B-type natriuretic protein (BNP) or N-terminal prohormone of BNP (NT-proBNP), may be useful for diagnosing heart dysfunction but also for monitoring purposes, especially during weaning from mechanical ventilation [100,101].”
BackgroundSelf-citationChiumello, D., Cressoni, M., Chierichetti, M., Tallarini, F., Botticelli, M., Berto, V., Mietto, C., & Gattinoni, L. (2008) · Critical Care · doi:10.1186/cc7139 · Cited by 144
Self-citationTranscutaneous P co 2 Monitoring During Initiation of Noninvasive Ventilation
Storre, J. H., Steurer, B., Kabitz, H., Dreher, M., & Windisch, W. (2007) · CHEST Journal · doi:10.1378/chest.07-1173 · Cited by 139 · cited 1×
“Transcutaneous capnometry off ers a continuous and noninvasive method of monitoring alveolar ventilation [103].”
MethodRelation between PaO2/FIO2 ratio and FIO2: a mathematical description
Aboab, J., Louis, B., Jonson, B., & Brochard, L. J. (2006) · Intensive Care Medicine · doi:10.1007/s00134-006-0337-9 · Cited by 135 · cited 1×
“Th e PaO2/FiO2 ratio is often a curvilinear (U-shaped) relationship, being at its lowest for moderate ranges of FiO2, depending on the shunt level, the hemoglobin value, and the arteriovenous diff erence in O2 content [21-23].”
BackgroundSelf-citationMultiplane ultrasound approach to quantify pleural effusion at the bedside
Remérand, F., Dellamonica, J., Zhang, M., Ferrari, F., Bouhemad, B., Yang, J., Arbelot, C., Lü, Q., Ichaï, C., & Rouby, J. (2010) · Intensive Care Medicine · doi:10.1007/s00134-010-1769-9 · Cited by 133 · cited 1×
“Chest ultrasonography and computed tomography Chest ultrasonography can be useful at the bedside for early identifi cation of edema as well as other abnormalities like pneumothorax or pleural eff usion [85,86].”
BackgroundKline, J. A. (2001) · JAMA · doi:10.1001/jama.285.6.761 · Cited by 128 · cited 1×
“When volumetric capnography is used as a bedside technique, the association of a normal D-dimer assay result plus a normal Vdalv is a highly sensitive screening test to rule out the diagnosis of pulmonary embolism [15].”
MethodLindgren, S., Hergès, H. O., Olegård, C., Söndergaard, S., Lundin, S., & Stenqvist, O. (2006) · Intensive Care Medicine · doi:10.1007/s00134-006-0425-x · Cited by 125 · cited 1×
“EIT can be used to show whether a recruitment maneuver has been successful and document the eff ects of positioning and of PEEP application [91,92].”
MethodSelf-citationJubran, A., Grant, B. J. B., Laghi, F. A., Parthasarathy, S., & Tobin, M. J. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200503-356oc · Cited by 122 · cited 1×
“Jubran and colleagues [62] showed that the esophageal pressure trend during a spon taneous breathing trial (SBT) complemented the pre dic tion of weaning outcome provided by the frequency/ VT index measured during the fi rst minute of an SBT.”
MethodSelf-citationGrasso, S., Leone, A. M., Michele, M. D., Anaclerio, R., Cafarelli, A., Ancona, G., Stripoli, T., Bruno, F., Pugliese, P., DAMBROSIO, M., et al. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000250391.89780.64 · Cited by 121 · cited 1×
“Cardiac biomarkers, like B-type natriuretic protein (BNP) or N-terminal prohormone of BNP (NT-proBNP), may be useful for diagnosing heart dysfunction but also for monitoring purposes, especially during weaning from mechanical ventilation [100,101].”
BackgroundRichard, J.-C., Brochard, L. J., Vandelet, P., Breton, L., Maggiore, S. M., Jonson, B., Clabault, K., Leroy, J., & Bonmarchand, G. (2003) · Critical Care Medicine · doi:10.1097/00003246-200301000-00014 · Cited by 116
Self-citationMonitoring dead space during recruitment and PEEP titration in an experimental model
Tusman, G., Suárez-Sipmann, F., Böhm, S. H., Pech, T., Reißmann, H., Meschino, G. J., Scandurra, A. G., & Hedenstierna, G. (2006) · Intensive Care Medicine · doi:10.1007/s00134-006-0371-7 · Cited by 115 · cited 1×
“When the application of positive end-expiratory pressure (PEEP) results in global lung recruitment, physio logic and alveolar dead space decrease [17]; the reverse is true when PEEP application results in lung overdistension [18].”
Background[B-type natriuretic peptide and weaning from mechanical ventilation].
Lai, L.-R., Wang, Z., & Tong, Z.-H. (2013) · PubMed · Cited by 110
Mancebo, J., Albaladejo, P., Touchard, D., Bak, E., Subirana‐Casacuberta, M., Lemaire, F., HARF, A., & Brochard, L. J. (2000) · Anesthesiology · doi:10.1097/00000542-200007000-00016 · Cited by 110 · cited 3×
“Th e surface encom passed within the passive P/V curve of the chest wall and the negative esophageal pressure swing during an inspiratory eff ort is shown in the so-called Campbell diagram [60,61].”
BackgroundMethodSelf-citationBratton, S. L., Chestnut, R. M., Ghajar, J., Hammond, F. M., Harris, O. A., Härtl, R., Manley, G. T., Nemecek, A. N., Newell, D. W., Rosenthal, G., et al. (2007) · Journal of Neurotrauma · doi:10.1089/neu.2007.9982 · Cited by 104
Lucangelo, U., Bernabè, F., Vatua, S., Degrassi, G., Villagra, A. L. R., Fernández, R., Romero, P. V., Saura, P., Borelli, M., & Blanch, L. L. (2007) · CHEST Journal · doi:10.1378/chest.07-0935 · Cited by 101 · cited 1×
“Several authors [9,10] have demonstrated that increased Vdphys values are independently associated with an increased risk of death in these patients.”
BackgroundSelf-citationBritos-Bray, M. F., Smoot, E. W., Liu, K. D., Thompson, B., Checkley, W., & Brower, R. G. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e31821cb774 · Cited by 101 · cited 1×
“For a given PaO2/FiO2 ratio, the higher the FiO2, the poorer the prognosis [24].”
BackgroundEffect of nail polish on oxygen saturation determined by pulse oximetry in critically ill patients
Hinkelbein, J., Genzwuerker, H. V., Sogl, R., & Fiedler, F. (2006) · Resuscitation · doi:10.1016/j.resuscitation.2006.06.024 · Cited by 100
Kallet, R. H., Alonso, J. A., Luce, J. M., & Matthay, M. A. (1999) · CHEST Journal · doi:10.1378/chest.116.6.1826 · Cited by 84
Effects of positive end-expiratory pressure on dead space and its partitions in acute lung injury
Beydon, L., Uttman, L., Rawal, R., & Jonson, B. (2002) · Intensive Care Medicine · doi:10.1007/s00134-002-1419-y · Cited by 80
Bikker, I. G., Leonhardt, S. K., Miranda, D. R., Bakker, J., & Gommers, D. A. M. P. J. (2010) · Critical Care · doi:10.1186/cc9036 · Cited by 74 · cited 2×
“Bikker and colleagues [94] clearly visualized improvement or loss of ventilation in dependent and nondependent parts of the lung by using EIT measurements in ICU patients.”
BackgroundSelf-citationLung-protective ventilation in neurosurgical patients
Lowe, G. J., & Ferguson, N. D. (2006) · Current Opinion in Critical Care · doi:10.1097/01.ccx.0000198055.29600.4b · Cited by 73 · cited 1×
“In mechanically ventilated neurological patients, no consensus has been reached about optimal VT, PEEP, PaO2, or PaCO2 levels [111], largely because these patients have been universally excluded from randomized trials of lung-protective ventilation because of concerns about potential intracranial pressure (ICP) increa…”
BackgroundRecruitability of the lung estimated by the pressure volume curve hysteresis in ARDS patients
Demory, D., Arnal, J.-M., Wysocki, M., Donati, S. Y., Granier, I., Corno, G., & Durand-Gasselin, J. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1167-8 · Cited by 71 · cited 1×
“Th e diff erence between the inspiratory and expiratory parts of the P/V curve are related, in part, to hysteresis [44], which refl ects whether PEEP should be increased or not.”
BackgroundEffects of Albuterol Inhalation on the Work of Breathing during Weaning from Mechanical Ventilation
Mancebo, J., Amaro, P., LORINO, H., Lemaire, F., HARF, A., & Brochard, L. J. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/144.1.95 · Cited by 69
Self-citationAnterior magnetic phrenic nerve stimulation: laboratory and clinical evaluation
Polkey, M. I., Duguet, A., Luo, Y. M., Hughes, P., Hart, N., Hamnegärd, C. H., Green, M., Similowski, T., & Moxham, J. (2000) · Intensive Care Medicine · doi:10.1007/s001340051319 · Cited by 67 · cited 1×
“Magnetic phrenic stimulation can be used to assess diaphragmatic function [51] as a noninvasive method in sedated and non-sedated patients but remains a test of respiratory muscle function rather than a monitoring tool and is used mainly in research.”
MethodBrown, L. M., Liu, K. D., & Matthay, M. A. (2009) · American Journal of Physiology-Lung Cellular and Molecular Physiology · doi:10.1152/ajplung.00127.2009 · Cited by 65 · cited 1×
“EVLW can be assessed only in perfused areas of the lung [34].”
BackgroundMarini, J. J. (2010) · Current Opinion in Critical Care · doi:10.1097/mcc.0b013e328342726e · Cited by 63
Variation of venous admixture, SF6 shunt, PaO, and the PaO/FiO ratio with FiO
Whiteley, J. P., Gavaghan, D. J., & Hahn, C. E. W. (2002) · British Journal of Anaesthesia · doi:10.1093/bja/88.6.771 · Cited by 56 · cited 1×
“Th e PaO2/FiO2 ratio is often a curvilinear (U-shaped) relationship, being at its lowest for moderate ranges of FiO2, depending on the shunt level, the hemoglobin value, and the arteriovenous diff erence in O2 content [21-23].”
BackgroundVentilatory strategies for patients with acute brain injury
Young, N. H., Rhodes, J. K. J., Mascia, L., & Andrews, P. (2009) · Current Opinion in Critical Care · doi:10.1097/mcc.0b013e32833546fa · Cited by 54
Marco, F. D., Devaquet, J., Lyazidi, A., Galia, F., da Costa, N. P., Fumagalli, R., & Brochard, L. J. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181b4a7e7 · Cited by 52 · cited 1×
“In patients with ARDS, the PaO2/FiO2 ratio is dependent on the PEEP level and can be a surrogate, though imperfect, marker of recruitment [25].”
BackgroundSelf-citationSteiner, L. A., Balestreri, M., Johnston, A. J., Czosnyka, M., Coles, J., Chatfield, D. A., Smielewski, P. S., Pickard, J. D., & Menon, D. K. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2463-6 · Cited by 50 · cited 1×
“Th e eff ect on ICP is not sustained, whereas CBF may remain low, raising risks of ischemia [113,114]; hyperventilation should, therefore, be avoided during the fi rst 24 hours after injury, when CBF is often already low [115].”
BackgroundQuesnel, C., Piednoir, P., Gelly, J., Nardelli, L., Garnier, M., Leçon-Malas, V., Lasocki, S., Bouadma, L., Philip, I., Elbim, C., et al. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e31822d718b · Cited by 45
Pelosi, P. P., Rocco, P. R. M., & de Abreu, M. G. (2011) · Current Opinion in Critical Care · doi:10.1097/mcc.0b013e328344ddbc · Cited by 44 · cited 1×
“CT could potentially have roles in guiding protective mechanical ventilation in ARDS and in appropriately setting VT and PEEP [90].”
Self-citationPatroniti, N. A., Saini, M., Zanella, A., Weismann, D., Isgrò, S., Bellani, G., Foti, G., & Pesenti, A. M. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1218-1 · Cited by 43 · cited 1×
“Th e precision of this method seems acceptable, and the method can be used even in the most severely hypoxemic patients [79,80].”
MethodSelf-citationPermutt, S. (1988) · PubMed · Cited by 43
Non-pulmonary factors strongly influence the stress index
Formenti, P., Graf, J., Santos, A., Gard, K. E., Faltesek, K., Adams, A. B., Dries, D. J., & Marini, J. J. (2011) · Intensive Care Medicine · doi:10.1007/s00134-011-2133-4 · Cited by 34 · cited 1×
“Th e clinical place and reliability of the stress index are still debated [48].”
BackgroundManagement of traumatic brain injury: first link in chain of survival
Minardi, J. J., & Crocco, T. J. (2009) · Mount Sinai Journal of Medicine A Journal of Translational and Personalized Medicine · doi:10.1002/msj.20105 · Cited by 27 · cited 1×
“Outcomes of critically ill neurological patients are driven mainly by the underlying neurological pathology [108,109], and the infl uence of extracerebral organ dysfunction and ventilatory management on outcomes in this group of patients is not well established [110].”
BackgroundManagement of Acute Brain Injury and Associated Respiratory Issues
Deem, S. A. (2006) · Respiratory Care · doi:10.4187/respcare.06510357 · Cited by 26 · cited 2×
“Th e eff ect on ICP is not sustained, whereas CBF may remain low, raising risks of ischemia [113,114]; hyperventilation should, therefore, be avoided during the fi rst 24 hours after injury, when CBF is often already low [115].”
BackgroundBouhemad, B., Ferrari, F., Leleu, K., Arbelot, C., Lü, Q., & Rouby, J. (2008) · Anesthesiology · doi:10.1097/01.anes.0000296067.02462.34 · Cited by 23 · cited 1×
“Measurement of pulmonary artery pressure can also be reliably obtained by Doppler measurements [98].”
BackgroundCO2 elimination at varying inspiratory pause in acute lung injury
Aboab, J., Niklason, L., Uttman, L., Kouatchet, A., Brochard, L. J., & Jonson, B. (2006) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2007.00699.x · Cited by 19 · cited 1×
“Th erefore, volumetric capnography may also be helpful to identify overdistension or better alveolar gas diff usion [19].”
BackgroundSelf-citationOwens, R. L., HESS, D. R., Malhotra, A., Venegas, J. G., & Harris, R. S. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e318186afcb · Cited by 18 · cited 2×
“Interpretation of P/V curves is diffi cult in the presence of altered chest compliance [43].”
Background
Cited by
Impact of prolonged assisted ventilation on diaphragmatic efficiency: NAVA versus PSV
Di mussi, R., Spadaro, S., Mirabella, L., Volta, C. A., Serio, G., Staffieri, F., Dambrosio, M., Cinnella, G., Bruno, F., & Grasso, S. (2016) · Critical Care · doi:10.1186/s13054-015-1178-0 · Cited by 404
Respiration rate and volume measurements using wearable strain sensors
Chu, M., Nguyen, T., Pandey, V., Zhou, Y., Pham, H. N., Bar-Yoseph, R., Radom-Aizik, S., Jain, R., Cooper, D. M., & Khine, M. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0083-3 · Cited by 403
Metadata
- Authors
- Brochard, L., Martin, G. S., Blanch, L., Pelosi, P., Belda, F. J., Jubran, A., Gattinoni, L., Mancebo, J., Ranieri, V. M., Richard, J.-C. M., Gommers, D., Vieillard-Baron, A., Pesenti, A., Jaber, S., Stenqvist, O., & Vincent, J.-L.
- Venue
- Critical Care
- Published
- 2012
- Volume
- 16
- Issue
- 2
- Pages
- 219
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W2027989613
- Cited by
- 160
- References
- 100
- FWCI
- 8.06
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.