A structured overview of trends and technologies used in dynamic hand orthoses
Open accessThe DOI matches its Crossref record; 193 of the 193 references it cites were found in a registry or an index.
Abstract
The development of dynamic hand orthoses is a fast-growing field of research and has resulted in many different devices. A large and diverse solution space is formed by the various mechatronic components which are used in these devices. They are the result of making complex design choices within the constraints imposed by the application, the environment and the patient's individual needs. Several review studies exist that cover the details of specific disciplines which play a part in the developmental cycle. However, a general collection of all endeavors around the world and a structured overview of the solution space which integrates these disciplines is missing. In this study, a total of 165 individual dynamic hand orthoses were collected and their mechatronic components were categorized into a framework with a signal, energy and mechanical domain. Its hierarchical structure allows it to reach out towards the different disciplines while connecting them with common properties. Additionally, available arguments behind design choices were collected and related to the trends in the solution space. As a result, a comprehensive overview of the used mechatronic components in dynamic hand orthoses is presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Soft robotic glove for combined assistance and at-home rehabilitation
Polygerinos, P., Wang, Z., Galloway, K. C., Wood, R. J., & Walsh, C. J. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.014 · Cited by 1,617 · cited 2×
“Sometimes physical therapy can be offered through assistance [19], in which case the daily assistance imposes the most restrictive design constraints.”
BackgroundTHE PREHENSILE MOVEMENTS OF THE HUMAN HAND
Napier, J. R. (1956) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.38b4.902 · Cited by 1,571
Effects of Robot-Assisted Therapy on Upper Limb Recovery After Stroke: A Systematic Review
Kwakkel, G., Kollen, B. J., & Krebs, H. I. (2008) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968307305457 · Cited by 1,503 · cited 2×
“This is an increasingly popular field in rehabilitation devices, as it ideally reduces time in the clinic andmaximizes hours of physical therapy [5].”
BackgroundAugmented visual, auditory, haptic, and multimodal feedback in motor learning: A review
Sigrist, R., Rauter, G., Riener, R., & Wolf, P. (2013) · Psychonomic Bulletin & Review · doi:10.3758/s13423-012-0333-8 · Cited by 1,416 · cited 2×
“Determining the ideal form of augmented feedback signals is challenging, hard to verify and in many cases related to task complexity [24].”
BackgroundMethodPostural Hand Synergies for Tool Use
Santello, M., Flanders, M., & Soechting, J. F. (1998) · The Journal of Neuroscience · doi:10.1523/jneurosci.18-23-10105.1998 · Cited by 1,215
A survey on robotic devices for upper limb rehabilitation
Maciejasz, P., Eschweiler, J., Gerlach-Hahn, K., Jansen-Troy, A., & Leonhardt, S. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-3 · Cited by 1,210 · cited 5×
“The resulting diversity between the different devices can be illustrated by the elaborate overviews on robotic devices [4], training modalities [3] and intention detection systems [7] they use.”
BackgroundInfluentialPrange, G. B., Jannink, M. J. A., Groothuis-Oudshoorn, C. G. M., Hermens, H. J., & IJzerman, M. J. (2006) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.04.0076 · Cited by 917 · cited 1×
“A clinical tool can be used for diagnostic purposes, but are mostly used for robot-assisted rehabilitation at the clinic with reduced active workload for the professional caregiver [5, 14–16].”
MethodThe Rutgers Master II-new design force-feedback glove
Bouzit, M., Burdea, G., Popescu, G., & Boian, R. (2002) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2002.1011262 · Cited by 570 · cited 2×
“It’s aYear ranges are determined by the year span between found literature sources and my differ from the actual time of development bActuator DOF = number of individually controlled actuators (zero means fully passive) cWrist can be assisted, resisted, limited or locked [29] in pronation/supination (PS), flexion/exte…”
BackgroundTowards a soft pneumatic glove for hand rehabilitation
Polygerinos, P., Lyne, S., Wang, Z., Nicolini, L. F., Mosadegh, B., Whitesides, G. M., & Walsh, C. J. (2013) · 2013 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2013.6696549 · Cited by 527 · cited 1×
“Polygerinos [19, 331, 332] USA 2013–2015 HdO general therapy/assistance 4 N/A”
BackgroundHaptic shared control: smoothly shifting control authority?
Abbink, D. A., Mulder, M., & Boer, E. R. (2012) · Cognition, Technology & Work · doi:10.1007/s10111-011-0192-5 · Cited by 525 · cited 1×
“Signal The first tree diagram within this domain encompasses the training modalities from [3] employed by the controller, subdivided according to who has authority over the device’s movement [27].”
BackgroundCurrent hand exoskeleton technologies for rehabilitation and assistive engineering
Heo, P., Gu, G. M., Lee, S.-J., Rhee, K., & Kim, J. (2012) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-012-0107-2 · Cited by 517 · cited 1×
“Their development is a fast-growing field of research and has already resulted in a large variety of devices [1–4].”
BackgroundTimmermans, A. A., Seelen, H. A., Willmann, R. D., & Kingma, H. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-1 · Cited by 483
Developments in hardware systems of active upper-limb exoskeleton robots: A review
Gopura, R. A. R. C., Bandara, D. S. V., Kiguchi, K., & Mann, G. K. I. (2016) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2015.10.001 · Cited by 480
Exoskeletons and orthoses: classification, design challenges and future directions
Herr, H. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-21 · Cited by 477
Exo-Glove: A Wearable Robot for the Hand with a Soft Tendon Routing System
In, H., Kang, B. B., Sin, M., & Cho, K.-J. (2015) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2014.2362863 · Cited by 473 · cited 1×
“SNU Exo-Glove [85, 93, 333–335] South Korea 2011–2015 WHFO general therapy/assistance 3 N/A”
Basteris, A., Nijenhuis, S. M., Stienen, A. H., Buurke, J. H., Prange, G. B., & Amirabdollahian, F. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-111 · Cited by 408 · cited 4×
“Signal The first tree diagram within this domain encompasses the training modalities from [3] employed by the controller, subdivided according to who has authority over the device’s movement [27].”
BackgroundResultInfluentialSelf-citationKinematic Design to Improve Ergonomics in Human Machine Interaction
Schiele, A., & van der Helm, F. C. T. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.881565 · Cited by 386 · cited 1×
“Even tissue damage can occur, where pressure sores, joint dislocations or cartilage damage are among the possibilities depending on the user [102, 103].”
BackgroundAsif, U., & Iqbal, J. (2012) · International Journal of Advanced Robotic Systems · doi:10.5772/7789 · Cited by 377
An EMG-Controlled Robotic Hand Exoskeleton for Bilateral Rehabilitation
Leonardis, D., Chisari, C., Bergamasco, M., Frisoli, A., Barsotti, M., Loconsole, C., Solazzi, M., Troncossi, M., Mazzotti, C., Castelli, V. P., et al. (2015) · IEEE Transactions on Haptics · doi:10.1109/toh.2015.2417570 · Cited by 339
Yap, H. K., Lim, J. H., Nasrallah, F., Goh, J. C. H., & Yeow, R. C. H. (2015) · 2015 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2015.7139889 · Cited by 299 · cited 1×
“ExoGlove [316–319] Singapore 2015 HdO general therapy/assistance 1 N/A”
MethodRobot-assisted rehabilitation of hand function
Balasubramanian, S., Klein, J., & Burdet, E. (2010) · Current Opinion in Neurology · doi:10.1097/wco.0b013e32833e99a4 · Cited by 287 · cited 1×
“Their development is a fast-growing field of research and has already resulted in a large variety of devices [1–4].”
BackgroundDevelopment and pilot testing of HEXORR: Hand EXOskeleton Rehabilitation Robot
Schabowsky, C. N., Godfrey, S. B., Holley, R. J., & Lum, P. S. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-36 · Cited by 280 · cited 3×
“Reported arguments include the increased possibilities for both position and torque control [64], high mechanical bandwidth [65] and general performance in the torquevelocity space [13].”
BackgroundMethodConnelly, L., Jia, Y., Toro, M. L., Stoykov, M. E., Kenyon, R. V., & Kamper, D. G. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2047588 · Cited by 271 · cited 1×
“PneuGlove [146–148] USA 2006–2010 HdO post-stroke therapy 5 N/A”
MethodGupta, A., O'Malley, M. K., Patoglu, V., & Burgar, C. (2008) · The International Journal of Robotics Research · doi:10.1177/0278364907084261 · Cited by 255 · cited 1×
“READAPT [188–192] USA 2008–2015 WHFO post-stroke measurement/therapy 8 (+3 wrist) Assisted (PS, FE, RUD)”
Chiri, A., Vitiello, N., Giovacchini, F., Roccella, S., Vecchi, F., & Carrozza, M. C. (2012) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2011.2144614 · Cited by 254 · cited 4×
“Nonetheless, both cable systems most resemble the tendon mechanism in the natural hand [61, 92– 97] and are often an effective method of proximally placing the actuators to reduce the inertia of moving parts [13, 85, 96, 98, 99].”
BackgroundMethodInfluentialSoft robotic glove for hand rehabilitation and task specific training
Polygerinos, P., Galloway, K. C., Savage, E., Herman, M., Donnell, K. O., & Walsh, C. J. (2015) · 2015 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2015.7139597 · Cited by 239 · cited 1×
“Polygerinos [19, 331, 332] USA 2013–2015 HdO general therapy/assistance 4 N/A”
BackgroundAn EMG-Controlled Exoskeleton for Hand Rehabilitation
Mulas, M., Folgheraiter, M., & Gini, G. (2005) · 9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005. · doi:10.1109/icorr.2005.1501122 · Cited by 225 · cited 1×
“Mulas [195] Italy 2005 WHFO general physical therapy 2 Limited (PS, FE, RUD)”
BackgroundIson, M., & Artemiadis, P. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/051001 · Cited by 225 · cited 1×
“Command signal Detecting the user’s intention to serve as a command signal for the device is one of the larger challenges, because the control of the device is expected to be both intuitive and robust [35].”
BackgroundDevelopment and control of a hand exoskeleton for rehabilitation of hand injuries
Wege, A., & Hommel, G. (2005) · 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2005.1545506 · Cited by 221 · cited 2×
“Wege [37, 87, 198–200] Germany 2005–2007 HdO general physical therapy 20 N/A”
BackgroundMehrholz, J., Platz, T., Kugler, J., & Pohl, M. (2008) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006876.pub2 · Cited by 219
Proprioceptive Feedback and Brain Computer Interface (BCI) Based Neuroprostheses
Ramos-Murguialday, A., Schürholz, M., Caggiano, V., Wildgruber, M., Caria, A., Hammer, E. M., Halder, S., & Birbaumer, N. (2012) · PLoS ONE · doi:10.1371/journal.pone.0047048 · Cited by 215 · cited 1×
“Ramos [118, 119] Germany 2009–2012 WHFO post-stroke therapy 4 Locked (PS, FE, RUD)”
BackgroundBrokaw, E. B., Black, I., Holley, R. J., & Lum, P. S. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2157705 · Cited by 197 · cited 2×
“Other usages include applications where unidirectional and passive forces are sufficient to overcome an impairment, which is the case when compensating hyperflexion [62].”
BackgroundA Haptic Knob for Rehabilitation of Hand Function
Lambercy, O., Dovat, L., Gassert, R., Burdet, E., Teo, C. L., & Milner, T. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903913 · Cited by 196 · cited 2×
“They are also the least similar to the type of therapy a physical therapist can provide, and their low use implies that these methods aYear ranges are determined by the year span between found literature sources and my differ from the actual time of development bActuator DOF = number of individually controlled actuato…”
BackgroundA Powered Finger–Thumb Wearable Hand Exoskeleton With Self-Aligning Joint Axes
Cempini, M., Cortese, M., & Vitiello, N. (2015) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2014.2315528 · Cited by 193 · cited 3×
“HX [96, 271–274] Italy 2013–2015 WHFO general physical therapy 2 Locked (RUD)”
BackgroundMethodModeling and Control of the Twisted String Actuation System
Palli, G., Natale, C., May, C., Melchiorri, C., & Wurtz, T. (2013) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2011.2181855 · Cited by 190 · cited 1×
“An interesting development here lies in the twisted string actuation system, which reaches high reduction ratios by twisting strands on one end and creating linear motion on the other end [66, 67].”
BackgroundAgarwal, P., Fox, J., Yun, Y., O’Malley, M. K., & Deshpande, A. D. (2015) · The International Journal of Robotics Research · doi:10.1177/0278364915598388 · Cited by 189
Non-invasive control interfaces for intention detection in active movement-assistive devices
Lobo-Prat, J., Kooren, P. N., Stienen, A. H. A., Herder, J. L., Koopman, H. F. J. M., & Veltink, P. H. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-168 · Cited by 173 · cited 3×
“A second tree diagram covers the command signal required to activate the device, similar to [7].”
BackgroundSelf-citationJones, C. L., Wang, F., Morrison, R. M., Sarkar, N., & Kamper, D. G. (2012) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2012.2224359 · Cited by 172 · cited 6×
“They are also the least similar to the type of therapy a physical therapist can provide, and their low use implies that these methods aYear ranges are determined by the year span between found literature sources and my differ from the actual time of development bActuator DOF = number of individually controlled actuato…”
BackgroundMethodInfluentialA new hand exoskeleton device for rehabilitation using a three-layered sliding spring mechanism
Arata, J., Ohmoto, K., Gassert, R., Lambercy, O., FUJIMOTO, H., & Wada, I. (2013) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2013.6631126 · Cited by 166 · cited 2×
“Arata [63] Japan 2013 HdO general therapy/assistance 1 Limited (FE, RUD)”
BackgroundA Robotic Device for Hand Motor Therapy after Stroke
Takahashi, C. D., Der-Yeghiaian, L., Le, V., & Cramer, S. C. (2005) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2005.1501041 · Cited by 164 · cited 1×
“HWARD [30] USA 2005 WHFO post-stroke therapy 2 (+1 wrist) Locked (PS, RUD) Assisted (FE)”
MethodRML Glove—An Exoskeleton Glove Mechanism With Haptics Feedback
MA, Z., & Ben-Tzvi, P. (2015) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2014.2305842 · Cited by 163 · cited 4×
“SAFE Glove [354, 355] USA 2015 HdO VR feedback 6 N/A”
BackgroundInfluentialComparison of control strategies for an EMG controlled orthotic exoskeleton for the hand
DiCicco, M., Lucas, L., & Matsuoka, Y. (2004) · IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004 · doi:10.1109/robot.2004.1308056 · Cited by 163 · cited 1×
“DiCicco [291] USA 2004 WHFO tetraplegic assistance 2 Limited (FE, RUD)”
BackgroundActuator Classification and Selection—The Development of a Database
Zupan, M., Ashby, M. F., & Fleck, N. A. (2002) · Advanced Engineering Materials · doi:10.1002/adem.200290009 · Cited by 161 · cited 1×
“The diagrams have a similar structure and are subdivided according to feasible types of energy and stimulus from [25] and [26].”
BackgroundAn Actuated Finger Exoskeleton for Hand Rehabilitation Following Stroke
Worsnopp, T., Peshkin, M. A., Colgate, J. E., & Kamper, D. G. (2007) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428530 · Cited by 160 · cited 2×
“CAFE [13, 124, 125] USA 2007–2014 FO post-stroke measurement 6 Locked (FE, RUD)”
MethodMUNDUS project: MUltimodal Neuroprosthesis for daily Upper limb Support
Pedrocchi, A., Ferrante, S., Ambrosini, E., Gandolla, M., Casellato, C., Schauer, T., Klauer, C., Pascual, J., Vidaurre, C., Gföhler, M., et al. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-66 · Cited by 156 · cited 3×
“MUNDUS hand orthosis [36] Italy 2013 HdO tetraplegic assistance 1 N/A”
BackgroundMethodReach & Grasp Therapy: Design and Control of a 9-DOF Robotic Neuro-rehabilitation System
Loureiro, R. C. V., & Harwin, W. (2007) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428510 · Cited by 148
Technologies and combination therapies for enhancing movement training for people with a disability
Reinkensmeyer, D. J., & Boninger, M. L. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-17 · Cited by 144 · cited 2×
“Little can be said about their efficacy, as the exact working principles behind a successful rehabilitation program are not yet fully known [17].”
BackgroundRen, Y., Park, H., & Zhang, L. (2009) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2009.5209482 · Cited by 143 · cited 1×
“IntelliArm hand module [134, 135] USA 2008–2009 WHFO post-stroke measurement/therapy 1 (+2 wrist) Assisted (PS, FE) Locked (RUD)”
MethodMosher, R. S. (1967) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/670088 · Cited by 142
A novel exoskeleton robotic system for hand rehabilitation – Conceptualization to prototyping
Iqbal, J., Khan, H., Tsagarakis, N. G., & Caldwell, D. G. (2014) · Biocybernetics and Biomedical Engineering · doi:10.1016/j.bbe.2014.01.003 · Cited by 141 · cited 4×
“Pulley-cable systems are spatially constrained and require a continuous control of cable tension to maintain traction on the pulleys [13, 85, 86].”
BackgroundMethodInfluentialMakinson, B. J. (1971) · doi:10.21236/ad0724797 · Cited by 140
Lee, S. W., Landers, K. A., & Park, H. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2298362 · Cited by 136 · cited 2×
“Underactuation, in particular, is a popular method as it reduces weight and complexity [65, 74, 86, 93, 97, 109, 111] and it facilitates passive adaptation for better object manipulation [86, 94].”
BackgroundMethodMehrholz, J., Platz, T., Kugler, J., & Pohl, M. (2009) · Stroke · doi:10.1161/strokeaha.108.536219 · Cited by 135
Mechanical design of a novel Hand Exoskeleton for accurate force displaying
Fontana, M., Dettori, A., Salsedo, F., & Bergamasco, M. (2009) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2009.5152591 · Cited by 134 · cited 1×
“Fontana [347, 348] Italy 2009–2013 HdO VR feedback, teleoperation 6 N/A”
BackgroundWearable power assist device for hand grasping using pneumatic artificial rubber muscle
SASAKI, D., Noritsugu, T., TAKAIWA, M., & Yamamoto, H. (2005) · IEEE RO-MAN · doi:10.1109/roman.2004.1374840 · Cited by 131
Human hand modelling: kinematics, dynamics, applications
Gustus, A., Stillfried, G., Visser, J. M. A., Jörntell, H., & van der Smagt, P. (2012) · Biological Cybernetics · doi:10.1007/s00422-012-0532-4 · Cited by 130 · cited 2×
“Additionally, the rotation axis of a finger joint is not constant [104], i.”
BackgroundMethodDesign of a Rotational Hydroelastic Actuator for a Powered Exoskeleton for Upper Limb Rehabilitation
Stienen, A. H. A., Hekman, E. E. G., ter Braak, H., Aalsma, A. M. M., van der Helm, F. C. T., & van der Kooij, H. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2018628 · Cited by 128 · cited 1×
“For example, definitions for powerto-weight ratios are often unclear [76] and a distinction can bemade between high- and low-force bandwidth [77].”
BackgroundSelf-citationDesign and Characterization of Hand Module for Whole-Arm Rehabilitation Following Stroke
Masia, L., Krebs, H. I., Cappa, P., & Hogan, N. (2007) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2007.901928 · Cited by 124 · cited 2×
“InMotion Hand Robot [89, 128, 129] USA 1991–2007 HdO post-stroke therapy 1 N/A”
Amirabdollahian, F., Ateş, S., Basteris, A., Cesario, A., Buurke, J. H., Hermens, H. J., Hofs, D. H. W., Johansson, E., Mountain, G. A., Nasr, N., et al. (2014) · Robotica · doi:10.1017/s0263574714002288 · Cited by 120
Self-citationCordo, P. J., Lutsep, H. L., Cordo, L., Wright, W. G., Cacciatore, T. W., & Skoss, R. (2008) · Neurorehabilitation and neural repair · doi:10.1177/1545968308317437 · Cited by 120 · cited 1×
“AMES hand module [53, 54, 156, 157] USA 2009–2014 WHFO post-stroke therapy 1 (+1 wrist) Locked (PS, RUD) Assisted (FE)”
MethodPatterns of decline in upper limb function of boys and men with DMD: an international survey
Janssen, M. M. H. P., Bergsma, A., Geurts, A. C. H., & de Groot, I. J. M. (2014) · Journal of Neurology · doi:10.1007/s00415-014-7316-9 · Cited by 120 · cited 1×
“DuchenneMuscular Dystrophy [6]).”
A soft robotic exomusculature glove with integrated sEMG sensing for hand rehabilitation
Delph, M. A., Fischer, S. A., Gauthier, P. W., Luna, C. H. M., Clancy, E. A., & Fischer, G. S. (2013) · 2013 IEEE 13th International Conference on Rehabilitation Robotics (ICORR) · doi:10.1109/icorr.2013.6650426 · Cited by 119 · cited 2×
“Nonetheless, both cable systems most resemble the tendon mechanism in the natural hand [61, 92– 97] and are often an effective method of proximally placing the actuators to reduce the inertia of moving parts [13, 85, 96, 98, 99].”
HANDEXOS: Towards an exoskeleton device for the rehabilitation of the hand
Chiri, A., Giovacchini, F., Vitiello, N., Cattin, E., Roccella, S., Vecchi, F., & Carrozza, M. C. (2009) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2009.5354376 · Cited by 116 · cited 2×
“HANDEXOS [98, 216, 217] Italy 2009–2012 FO post-stroke therapy 1 N/A”
BackgroundJointless structure and under-actuation mechanism for compact hand exoskeleton
In, H., Cho, K.-J., Kim, K., & Lee, B. (2011) · 2011 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975394 · Cited by 111 · cited 3×
“SNU Exo-Glove [85, 93, 333–335] South Korea 2011–2015 WHFO general therapy/assistance 3 N/A”
BackgroundMethodA Subject-Adaptive Controller for Wrist Robotic Rehabilitation
Pehlivan, A. U., Sergi, F., & O’Malley, M. K. (2014) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2014.2340697 · Cited by 109 · cited 1×
“READAPT [188–192] USA 2008–2015 WHFO post-stroke measurement/therapy 8 (+3 wrist) Assisted (PS, FE, RUD)”
Finger Tapping Clinimetric Score Prediction in Parkinson's Disease Using Low-Cost Accelerometers
Stamatakis, J., Ambroise, J., Crémers, J., Sharei, H., Delvaux, V., Macq, B., & Garraux, G. (2013) · Computational Intelligence and Neuroscience · doi:10.1155/2013/717853 · Cited by 108
Five-fingered assistive hand with mechanical compliance of human finger
Hasegawa, Y., Mikami, Y., Watanabe, K., & Sankai, Y. (2008) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2008.4543290 · Cited by 108 · cited 1×
“Hasegawa [321–326] Japan 2008–2015 WHFO power assistance 8 (+ 4 wrist) Assisted (PS, FE)”
BackgroundTaheri, H., Rowe, J. B., Gardner, D., Chan, V., Gray, K., Bower, C., Reinkensmeyer, D. J., & Wolbrecht, E. T. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-10 · Cited by 108
IntelliArm: An exoskeleton for diagnosis and treatment of patients with neurological impairments
Park, H., Ren, Y., & Zhang, L. (2008) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2008.4762876 · Cited by 106 · cited 1×
“IntelliArm hand module [134, 135] USA 2008–2009 WHFO post-stroke measurement/therapy 1 (+2 wrist) Assisted (PS, FE) Locked (RUD)”
MethodSensing and Force-Feedback Exoskeleton (SAFE) Robotic Glove
Ben‐Tzvi, P., & Ma, Z. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2378171 · Cited by 100
Use of Magnetorheological Fluid in a Force Feedback Glove
Winter, S. H., & Bouzit, M. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891401 · Cited by 100 · cited 1×
“MRAGES [197] USA 2007 HdO general physical therapy 5 N/A”
BackgroundElectromyography sensor based control for a hand exoskeleton
Wege, A., & Zimmermann, A. (2007) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2007.4522381 · Cited by 97 · cited 2×
“Wege [37, 87, 198–200] Germany 2005–2007 HdO general physical therapy 20 N/A”
BackgroundMethodA design of fine motion assist equipment for disabled hand in robotic rehabilitation system
Ito, S., Kawasaki, H., Ishigure, Y., NATSUME, M., Mouri, T., & Nishimoto, Y. (2009) · Journal of the Franklin Institute · doi:10.1016/j.jfranklin.2009.02.009 · Cited by 93 · cited 1×
“Kawasaki [44, 169–172] Japan 2004–2014 WHFO post-stroke therapy 16 (+ 2 wrist) Assisted (PS, FE) Locked (RUD)”
Multi-fingered exoskeleton haptic device using passive force feedback for dexterous teleoperation
Koyama, T., Yamano, I., Takemura, K., & Maéno, T. (2003) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/irds.2002.1041713 · Cited by 91
Rosati, G., Rodà, A., Avanzini, F., & Masiero, S. (2013) · Computational Intelligence and Neuroscience · doi:10.1155/2013/586138 · Cited by 89
A low-friction passive fluid transmission and fluid-tendon soft actuator
Whitney, J. P., Glisson, M., Brockmeyer, E., & Hodgins, J. K. (2014) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2014.6942946 · Cited by 88 · cited 2×
“Despite this, hydraulic transmissions remain promising at similar scales [100] and are able to provide a more efficient alternative compared to a similar cable mechanism [101].”
BackgroundTadano, K., Akai, M., KADOTA, K., & Kawashima, K. (2010) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2010.5509393 · Cited by 85 · cited 1×
“Tadano [73] Japan 2010 HdO power assistance 10 N/A”
BackgroundA Mechatronic System for Robot-Mediated Hand Telerehabilitation
Cortese, M., Cempini, M., Ribeiro, P. R. D. A., Soekadar, S. R., Carrozza, M. C., & Vitiello, N. (2014) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2014.2353298 · Cited by 84 · cited 1×
“HX [96, 271–274] Italy 2013–2015 WHFO general physical therapy 2 Locked (RUD)”
BackgroundAubin, P. M., Sallum, H. M., Walsh, C. J., Stirling, L., & Correia, A. (2013) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2013.6650500 · Cited by 83 · cited 1×
“IOTA [249] USA 2014 WHFO pediatric rehabilitation 2 N/A”
BackgroundNycz, C. J., Delph, M. A., & Fischer, G. S. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319243 · Cited by 82 · cited 1×
“Delph II [99, 315] USA 2013–2015 HdO post-stroke therapy/assistance 5 N/A”
Design and Characterization of Soft Actuator for Hand Rehabilitation Application
Yap, H. K., Goh, J. C., & Yeow, C. (2014) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-319-11128-5_92 · Cited by 79 · cited 1×
“ExoGlove [316–319] Singapore 2015 HdO general therapy/assistance 1 N/A”
Occupational andphysical therapy using a hand exoskeleton based exerciser
Satakogiou, I., Tsagarakis, N. G., & Caldwell, D. G. (2005) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2004.1389861 · Cited by 78 · cited 1×
“Sarakoglou [50] UK 2004 HdO general physical therapy 7 N/A”
BackgroundCineplasty as a control input for externally powered prosthetic components.
Weir, R. F. F., Heckathorne, C. W., & Childress, D. S. (2001) · PubMed · Cited by 77
Smit, G., Plettenburg, D. H., & van der Helm, F. C. T. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2342158 · Cited by 77 · cited 1×
“across fingers) underactuation which is an upcoming feature and allows passive adaptation to 3D objects [93, 112].”
BackgroundSelf-citationAubin, P. M., Petersen, K., Sallum, H. M., Walsh, C. J., Correia, A., & Stirling, L. (2014) · International Journal of Intelligent Computing and Cybernetics · doi:10.1108/ijicc-10-2013-0043 · Cited by 71
Hesse, S., Kuhlmann, H., Wilk, J., Tomelleri, C., & Kirker, S. G. B. (2008) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-5-21 · Cited by 70
MRC-glove: A fMRI compatible soft robotic glove for hand rehabilitation application
Yap, H. K., Lim, J. H., Nasrallah, F. A., Low, F.-Z., Goh, J., & Yeow, C. (2015) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2015.7281289 · Cited by 68
Kinematics and design of a portable and wearable exoskeleton for hand rehabilitation
Cempini, M., Rossi, S., Lenzi, T., Cortese, M., Giovacchini, F., Vitiello, N., & Carrozza, M. C. (2013) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2013.6650414 · Cited by 64 · cited 1×
“HX [96, 271–274] Italy 2013–2015 WHFO general physical therapy 2 Locked (RUD)”
BackgroundComparison of electromyography and force as interfaces for prosthetic control
Corbett, E. A., Perreault, E. J., & Kuiken, T. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.03.0028 · Cited by 64 · cited 1×
“Nonetheless, recent studies have shown that both methods (plant forces/motions and EMG) are feasible as a control interface [42, 43].”
BackgroundContribution of tactile feedback from the hand to the perception of force
Jones, L. A., & Piateski, E. (2005) · Experimental Brain Research · doi:10.1007/s00221-005-0259-8 · Cited by 64 · cited 1×
“A spatial separation between the palmar surface and the environment can affect force perception [57], hence facilitating tactile sensation is considered to be of great importance in dynamic hand orthoses [58].”
BackgroundNeurocognitive Robot-Assisted Therapy of Hand Function
Metzger, J.-C., Lambercy, O., Califfi, A., Conti, F., & Gassert, R. (2014) · IEEE Transactions on Haptics · doi:10.1109/toh.2013.72 · Cited by 60 · cited 1×
“ReHapticKnob [257–259] Switzerland 2011–2014 WHFO post-stroke measurement/therapy 1 (+1 wrist) Assisted (PS)”
fMRI-compatible rehabilitation hand device
Khanicheh, A., Muto, A., Triantafyllou, C., Weinberg, B., Astrakas, L. G., Tzika, A. A., & Mavroidis, C. (2006) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-3-24 · Cited by 60
Haptic Hand Exoskeleton for Precision Grasp Simulation
Fontana, M., Salsedo, F., Marcheschi, S., & Bergamasco, M. (2013) · Journal of Mechanisms and Robotics · doi:10.1115/1.4024981 · Cited by 59 · cited 1×
“Fontana [347, 348] Italy 2009–2013 HdO VR feedback, teleoperation 6 N/A”
BackgroundMR_CHIROD v.2: Magnetic Resonance Compatible Smart Hand Rehabilitation Device for Brain Imaging
Khanicheh, A., Mintzopoulos, D., Weinberg, B., Tzika, A. A., & Mavroidis, C. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.910286 · Cited by 59
Jeong, U., In, H., & Cho, K. (2013) · Intelligent Service Robotics · doi:10.1007/s11370-013-0135-5 · Cited by 57 · cited 1×
“SNU Exo-Glove [85, 93, 333–335] South Korea 2011–2015 WHFO general therapy/assistance 3 N/A”
A portable rehabilitation device for the Hand
Iqbal, J., Tsagarakis, N. G., Fiorilla, A. E., & Caldwell, D. G. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5627448 · Cited by 56 · cited 2×
“They are also the least similar to the type of therapy a physical therapist can provide, and their low use implies that these methods aYear ranges are determined by the year span between found literature sources and my differ from the actual time of development bActuator DOF = number of individually controlled actuato…”
BackgroundSato, K., Minamizawa, K., Kawakami, N., & Tachi, S. (2007) · ACM SIGGRAPH Emerging Technologies · doi:10.1145/1278280.1278291 · Cited by 55
Control of an optimal finger exoskeleton based on continuous joint angle estimation from EMG signals
Ngeo, J., Tamei, T., Shibata, T., Orlando, M. F., Behera, L., Saxena, A., & Dutta, A. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6609506 · Cited by 55 · cited 1×
“Orlando [237, 238] India 2010–2013 FO post-stroke therpapy 3 N/A”
BackgroundWhole-hand kinesthetic feedback and haptic perception in dextrous virtual manipulation
Tzafestas, C. S. (2003) · IEEE Transactions on Systems Man and Cybernetics - Part A Systems and Humans · doi:10.1109/tsmca.2003.812600 · Cited by 55 · cited 1×
“LRP hand master [339] France 2003 HdO VR feedback 14 N/A”
BackgroundCordo, P. J., Wolf, S. L., Lou, J., Bogey, R. A., Stevenson, M., Hayes, J., & Roth, E. J. (2013) · Neurology Report · doi:10.1097/npt.0000000000000023 · Cited by 55 · cited 2×
“For example, the force exerted by the device can be visualized [51], music can facilitate motor output [52] and stimulation of the muscle spindles through vibrations can give an enhanced sensation of motion to further enhance rehabilitation success [53, 54].”
BackgroundMethodControl System for Pneumatically Controlled Glove to Assist in Grasp Activities
Kline, T., Kamper, D. G., & Schmit, B. D. (2005) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2005.1501056 · Cited by 54 · cited 1×
“PneuGlove [146–148] USA 2006–2010 HdO post-stroke therapy 5 N/A”
MethodA wearable device for repetitive hand therapy
Xing, K., Xu, Q., He, J., Wang, Y., Liu, Z., & Huang, X. (2008) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2008.4762789 · Cited by 51 · cited 1×
“The main reported drawbacks are difficulties in control, expensive components and low bandwidth [69, 71, 75].”
BackgroundUse of a pneumatic glove for hand rehabilitation following stroke
Connelly, L., Stoykov, M. E., Jia, Y., Toro, M. L., Kenyon, R. V., & Kamper, D. G. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5335400 · Cited by 50 · cited 1×
“PneuGlove [146–148] USA 2006–2010 HdO post-stroke therapy 5 N/A”
MethodTjahyono, A. P., Aw, K. C., Devaraj, H., Surendra, W. A., Haemmerle, E., & Travaš‐Sejdić, J. (2013) · Industrial Robot the international journal of robotics research and application · doi:10.1108/01439911311309951 · Cited by 50 · cited 3×
“This includes the more straightforward hinge joints [61], but also those that use a virtual center of rotation with fixed rotation axis (e.”
BackgroundMethodPneumatic actuators: a comparison of energy-to-mass ratio's
Plettenburg, D. H. (2005) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2005.1502022 · Cited by 49 · cited 1×
“For example, definitions for powerto-weight ratios are often unclear [76] and a distinction can bemade between high- and low-force bandwidth [77].”
BackgroundSelf-citationA multi-DOF robotic exoskeleton interface for hand motion assistance
Iqbal, J., Tsagarakis, N. G., & Caldwell, D. G. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6090458 · Cited by 48 · cited 1×
“HEXOSYS-II [267–270] Italy 2010–2015 WHFO general physical therapy 5 Limited (FE, RUD)”
Four‐fingered lightweight exoskeleton robotic device accommodating different hand sizes
Iqbal, J., Tsagarakis, N. G., & Caldwell, D. G. (2015) · Electronics Letters · doi:10.1049/el.2015.0850 · Cited by 48
Design and Development of a Bilateral Therapeutic Hand Device for Stroke Rehabilitation
Rahman, A., & Al-Jumaily, A. A. (2013) · International Journal of Advanced Robotic Systems · doi:10.5772/56809 · Cited by 47 · cited 1×
“Rahman [239, 240] Australia 2012–2013 WHFO post-stroke therapy 5 N/A”
Customizable soft pneumatic finger actuators for hand orthotic and prosthetic applications
Low, J.-H., Ang, M. H., & Yeow, C. (2015) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2015.7281229 · Cited by 46 · cited 1×
“ExoGlove [316–319] Singapore 2015 HdO general therapy/assistance 1 N/A”
Finger exoskeleton for treatment of tendon injuries
Ertas, I. H., Hocaoğlu, E., Barkana, D. E., & Patoğlu, V. (2009) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2009.5209487 · Cited by 46 · cited 1×
“AssistOn-Finger [109, 158] Turkey 2009–2014 FO tendon injury treatment 1 Locked (FE, RUD)”
BackgroundNoninvasive brain-computer interface driven hand orthosis
King, C., Wang, P. T., Mizuta, M., Reinkensmeyer, D. J., H., A., Moromugi, S., & Nenadić, Z. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091432 · Cited by 45 · cited 1×
“King [47, 173, 174] USA 2009–2014 HdO post-stroke therapy 7 N/A”
BackgroundDesign and Development of a Hand Exoskeleton for Rehabilitation Following Stroke
Rahman, M. A., & Al-Jumaily, A. A. (2012) · Procedia Engineering · doi:10.1016/j.proeng.2012.07.279 · Cited by 45 · cited 1×
“Rahman [239, 240] Australia 2012–2013 WHFO post-stroke therapy 5 N/A”
BackgroundNathan, D. E., Johnson, M. J., & McGuire, J. R. (2009) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2008.04.0052 · Cited by 45 · cited 1×
“ADLER FES grasp glove [132, 133] USA 2007–2009 HdO post-stroke therapy Not clear Not clear”
BackgroundDesign of a 2-finger hand skeleton for VR grasping simulation
Stergiopoulos, P., Fuchs, P., & Laurgeau, C. (2003) · HAL · Cited by 42
An exoskeleton master hand for controlling DLR/HIT hand
Fang, H., Xie, Z., & Liu, H. (2009) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2009.5354624 · Cited by 42 · cited 1×
“Fang [344, 345] China 2009 HdO teleoperation 5 N/A”
BackgroundReachMAN: a personal robot to train reaching and manipulation
Yeong, C. F., Melendez-Calderon, A., Gassert, R., & Burdet, E. (2009) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2009.5354837 · Cited by 42 · cited 2×
“This makes it advantageous over exoskeletonbased devices [106], but also less suitable for applications with more strict design constraints on portability (i.”
BackgroundA Wearable Rehabilitation Robotic Hand Driven by PM-TS Actuators
Wu, J., Huang, J., Wang, Y., & Xing, K. (2010) · Lecture notes in computer science · doi:10.1007/978-3-642-16587-0_41 · Cited by 41 · cited 1×
“The main reported drawbacks are difficulties in control, expensive components and low bandwidth [69, 71, 75].”
BackgroundDesign and characterization of the ReHapticKnob, a robot for assessment and therapy of hand function
Metzger, J.-C., Lambercy, O., Chapuis, D., & Gassert, R. (2011) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2011.6094882 · Cited by 41 · cited 1×
“ReHapticKnob [257–259] Switzerland 2011–2014 WHFO post-stroke measurement/therapy 1 (+1 wrist) Assisted (PS)”
Power-Assistive Finger Exoskeleton With a Palmar Opening at the Fingerpad
Heo, P., & Kim, J. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2325948 · Cited by 40 · cited 3×
“OFX [58, 306, 307] South Korea 2013–2014 WHFO general assistance 1 Locked (FE, RUD)”
BackgroundNew design of dynamic orthoses for neurological conditions
Hoffman, H. B., & Blakey, G. L. (2011) · Neurorehabilitation · doi:10.3233/nre-2011-0632 · Cited by 40 · cited 1×
“SaeboFlex [211, 212] USA 2011 WHFO post-stroke therapy, hypertonia compensation 0 Locked (FE, RUD)”
Micro hydraulic system using slim artificial muscles for a wearable haptic glove
Ryu, D., Moon, K.-W., Nam, H., Lee, Y., Chun, C., Kang, S., & Song, J.-B. (2008) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2008.4651159 · Cited by 40 · cited 4×
“However, they also require high voltages [69] and show hysteresis [68].”
BackgroundInfluentialRobot-assisted Guitar Hero for finger rehabilitation after stroke
Taheri, H., Rowe, J. B., Gardner, D., Chan, V., Reinkensmeyer, D. J., & Wolbrecht, E. T. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346822 · Cited by 39 · cited 2×
“FINGER [52, 163, 164] USA 2011–2014 FO post-stroke therapy 1 Locked (PS, FE, RUD)”
MethodOchoa, J. M., Jia, Y., Narasimhan, D., & Kamper, D. G. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333630 · Cited by 39 · cited 1×
“J-Glove [40, 209] USA 2009–2011 WHFO post-stroke therapy 1 Locked (FE, RUD)”
Evaluation of EMG, force and joystick as control interfaces for active arm supports
Lobo-Prat, J., Keemink, A., Stienen, A., Schouten, A., Veltink, P., & Koopman, B. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-68 · Cited by 37 · cited 1×
“Nonetheless, recent studies have shown that both methods (plant forces/motions and EMG) are feasible as a control interface [42, 43].”
BackgroundSelf-citationJo, I., & Bae, J. (2015) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2015.7139982 · Cited by 37 · cited 1×
“Jo [352, 353] South Korea 2013–2015 HdO VR feedback 5 N/A”
BackgroundKinematics and workspace analysis of an exoskeleton for thumb and index finger rehabilitation
Zheng, R., & Li, J. (2010) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2010.5723307 · Cited by 37 · cited 1×
“HIT-Glove [165–168] China 2010–2014 FO post-stroke therapy 6 N/A”
Single degree-of-freedom exoskeleton mechanism design for finger rehabilitation
Wolbrecht, E. T., Reinkensmeyer, D. J., & Gracia, A. P. (2011) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975427 · Cited by 37 · cited 3×
“For example, the force exerted by the device can be visualized [51], music can facilitate motor output [52] and stimulation of the muscle spindles through vibrations can give an enhanced sensation of motion to further enhance rehabilitation success [53, 54].”
BackgroundMethodLelieveld, M. J., Maéno, T., & Tomiyama, T. (2006) · ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference (IDETC/CIE) · doi:10.1115/detc2006-99111 · Cited by 36 · cited 1×
“Lelieveld [88, 340] Japan 2006 FO VR feedback 4 N/A”
BackgroundA ssist O n -F inger : An under-actuated finger exoskeleton for robot-assisted tendon therapy
Ertas, I. H., Hocaoğlu, E., & Patoğlu, V. (2014) · Robotica · doi:10.1017/s0263574714001957 · Cited by 36 · cited 3×
“Underactuation, in particular, is a popular method as it reduces weight and complexity [65, 74, 86, 93, 97, 109, 111] and it facilitates passive adaptation for better object manipulation [86, 94].”
BackgroundMethodJeong, U., In, H., Lee, H., Kang, B. B., & Cho, K. (2015) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2015.7139895 · Cited by 36
On the design of ergonomic wearable robotic devices for motion assistance and rehabilitation
Chiri, A., Cempini, M., Rossi, S., Lenzi, T., Giovacchini, F., Vitiello, N., & Carrozza, M. C. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6347391 · Cited by 35 · cited 2×
“HANDEXOS [98, 216, 217] Italy 2009–2012 FO post-stroke therapy 1 N/A”
BackgroundDesign of a thumb exoskeleton for hand rehabilitation
Lambercy, O., Schröder, D., Zwicker, S., & Gassert, R. (2013) · International Convention on Rehabilitation Engineering & Assistive Technology · Cited by 35
Agarwal, P., & Deshpande, A. D. (2015) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2015.7281180 · Cited by 34 · cited 1×
“READAPT [188–192] USA 2008–2015 WHFO post-stroke measurement/therapy 8 (+3 wrist) Assisted (PS, FE, RUD)”
Performance Assessment of a Brain–Computer Interface Driven Hand Orthosis
King, C., Dave, K. R., Wang, P. T., Mizuta, M., Reinkensmeyer, D. J., Do, A. H., Moromugi, S., & Nenadić, Z. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-014-1066-9 · Cited by 34 · cited 2×
“King [47, 173, 174] USA 2009–2014 HdO post-stroke therapy 7 N/A”
BackgroundLambercy, O., Dovat, L., Johnson, V. B. K., Salman, B., Wong, S., Gassert, R., Milner, T. E., Teo, C. L., & Burdet, E. (2007) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428498 · Cited by 33 · cited 2×
“They are also the least similar to the type of therapy a physical therapist can provide, and their low use implies that these methods aYear ranges are determined by the year span between found literature sources and my differ from the actual time of development bActuator DOF = number of individually controlled actuato…”
BackgroundWearable hand rehabilitation robot capable of hand function assistance in stroke survivors
Bae, J.-H., Kim, Y.-M., & Moon, I. (2012) · 2022 9th IEEE RAS/EMBS International Conference for Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2012.6290736 · Cited by 32 · cited 3×
“DULEX-II [45, 214] South Korea 2009–2012 WHFO post-stroke therapy 2 (+ 1 wrist) Assisted (FE) Locked (RUD)”
MethodDesign of a Wearable Direct-driven Optimized Hand Exoskeleton Device
Iqbal, J., Tsagarakis, N. G., & Caldwell, D. G. (2011) · Repository@Hull (Worktribe) (University of Hull) · Cited by 32
A novel BCI-controlled pneumatic glove system for home-based neurorehabilitation
Coffey, A. L., Leamy, D. J., & Ward, T. E. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944407 · Cited by 32 · cited 1×
“Coffey [245] Ireland 2014 WHFO post-stroke therapy 1 Limited (PS, RUD) Assisted (FE)”
BackgroundElastomeric contractile actuators for hand rehabilitation splints
Carpi, F., Mannini, A., & Rossi, D. D. (2008) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.774644 · Cited by 31
The exoskeleton glove for control of paralyzed hands
Brown, P., Jones, D., Singh, S. K., & Rosen, J. M. (2002) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.1993.292051 · Cited by 31 · cited 1×
“Brown [290] USA 1993 HdO tetraplegic assistance 5 N/A”
BackgroundBackus, D. A., Cordo, P. J., Gillot, A., Kandilakis, C., Mori, M., & Raslan, A. M. T. (2014) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2014.03.011 · Cited by 30 · cited 2×
“For example, the force exerted by the device can be visualized [51], music can facilitate motor output [52] and stimulation of the muscle spindles through vibrations can give an enhanced sensation of motion to further enhance rehabilitation success [53, 54].”
BackgroundMethodFu, Y., Zhang, Q., Zhang, F., & Gan, Z. (2011) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma.2011.5985641 · Cited by 29 · cited 1×
“HIT-Glove [165–168] China 2010–2014 FO post-stroke therapy 6 N/A”
Jones, C. L., Wang, F., Osswald, C. R., Kang, X., Sarkar, N., & Kamper, D. G. (2010) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2010.5626057 · Cited by 28 · cited 2×
“CAFE [13, 124, 125] USA 2007–2014 FO post-stroke measurement 6 Locked (FE, RUD)”
MethodDesign and control of an actuated thumb exoskeleton for hand rehabilitation following stroke
Wang, F., Shastri, M., Jones, C. L., Gupta, V., Osswald, C. R., Kang, X., Kamper, D. G., & Sarkar, N. (2011) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2011.5980099 · Cited by 28 · cited 1×
“ATX [116] USA 2011 FO post-stroke measurement 5 N/A”
BackgroundApplication of Haptic Interface for Finger Exercise
Mali, U., Goljar, N., & Munih, M. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.881535 · Cited by 28
Evaluation of fingertip force accuracy in different support conditions of exoskeleton
Hasegawa, Y., Tokita, J., Kamibayashi, K., & Sankai, Y. (2011) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2011.5980512 · Cited by 28 · cited 1×
“Hasegawa [321–326] Japan 2008–2015 WHFO power assistance 8 (+ 4 wrist) Assisted (PS, FE)”
BackgroundInteractive rehabilitation robot for hand function training
Chen, M., Ho, S. K., Zhou, H., Pang, P. M. K., Hu, X., Ng, D., & Tong, R. K. (2009) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2009.5209564 · Cited by 27 · cited 1×
“Chen [203] China 2009 WHFO post-stroke therapy 5 Locked (FE, FE, RUD)”
BackgroundForce Control Strategy for a Hand Exoskeleton Based on Sliding Mode Position Control
Wege, A., Kondak, K., & Hommel, G. (2006) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2006.282169 · Cited by 27 · cited 1×
“Wege [37, 87, 198–200] Germany 2005–2007 HdO general physical therapy 20 N/A”
BackgroundUse of a Novel Robotic Interface to Study Finger Motor Control
Cruz, E. G., & Kamper, D. G. (2009) · Annals of Biomedical Engineering · doi:10.1007/s10439-009-9845-4 · Cited by 27 · cited 1×
“FingerBot [48] USA 2010 FO post-stroke measurement 3 N/A”
BackgroundProposal of a SkilMate finger for EVA gloves
Yamada, Y., Morizono, T., Sato, S., Shimohira, T., Umetani, Y., Yoshida, T., & Aoki, S. (2002) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2001.932807 · Cited by 27 · cited 1×
“SkilMate [56, 336] Japan 2001–2004 HdO power assistance 3 N/A”
BackgroundMetzger, J.-C., Lambercy, O., & Gassert, R. (2012) · IEEE Haptics Symposium · doi:10.1109/haptic.2012.6183769 · Cited by 26 · cited 1×
“ReHapticKnob [257–259] Switzerland 2011–2014 WHFO post-stroke measurement/therapy 1 (+1 wrist) Assisted (PS)”
A Portable Passive Physiotherapeutic Exoskeleton
Naidu, D., Stopforth, R., Bright, G., & Davrajh, S. (2012) · International Journal of Advanced Robotic Systems · doi:10.5772/52065 · Cited by 26 · cited 1×
“Naidu [220, 221] South Africa 2011–2012 WHFO post-stroke therapy 2 (+1 wrist) Assisted (PS) Locked (FE, RUD)”
BackgroundConti, R., Allotta, B., Meli, E., & Ridolfi, A. (2015) · Robotica · doi:10.1017/s0263574715000879 · Cited by 23 · cited 1×
“Conti [313] Italy 2015 HdO general assistance 4 N/A”
BackgroundHEnRiE - Haptic Environment for Reaching and Grasping Exercise
Mihelj, M., Podobnik, J., & Munih, M. (2008) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2008.4762810 · Cited by 23 · cited 1×
“HenRiE grasp module [143–145] Slovenia 2008–2010 WHFO post-stroke therapy 0 Locked (FE, RUD)”
BackgroundProprioceptive feedback in BCI
Ramos‐Murguialday, A., Halder, S., & Birbaumer, N. (2009) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2009.5109287 · Cited by 22 · cited 1×
“Ramos [118, 119] Germany 2009–2012 WHFO post-stroke therapy 4 Locked (PS, FE, RUD)”
BackgroundFinger Impedance Evaluation by Means of Hand Exoskeleton
Fiorilla, A. E., Nori, F., Masia, L., & Sandini, G. (2011) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0381-7 · Cited by 22 · cited 2×
“Fiorilla [12, 117] Italy 2009–2011 FO normal measurement 2 Limited (PS) Locked (FE, RUD)”
BackgroundMethodAugmented robotic device for EVA hand manoeuvres
Matheson, E., & Brooker, G. M. (2012) · Acta Astronautica · doi:10.1016/j.actaastro.2012.06.006 · Cited by 18 · cited 4×
“Matheson 1 [22, 23] Australia 2011–2012 WHFO general assistance 1 Limited (PS, FE, RUD)”
BackgroundInfluentialA finger exoskeleton for rehabilitation and brain image study
Tang, Z., Sugano, S., & Iwata, H. (2013) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2013.6650446 · Cited by 18 · cited 1×
“Tang [120–123] Japan 2011–2013 FO post-stroke measurement/therapy 1 Limited (FE)”
BackgroundUnluhisarcikli, O., Weinberg, B., Sivak, M. L., Mirelman, A., Bonato, P., & Mavroidis, C. (2010) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2010.5509806 · Cited by 16 · cited 1×
“Unluhisarcikli [149] USA 2008–2010 WHFO post-stroke therapy 2 (+1 wrist) Assisted (PS)”
BackgroundWu, J., Huang, J., Wang, Y., & Xing, K. (2012) · International Journal of Intelligent Computing and Cybernetics · doi:10.1108/17563781211208242 · Cited by 16 · cited 1×
“Wu [71, 75, 226–229] China 2008–2012 WHFO post-stroke therapy 2 Limited (PS) Locked (FE, RUD)”
BackgroundUpper limb and grasp rehabilitation and evaluation of stroke patients using HenRiE device
Podobnik, J., Mihelj, M., & Munih, M. (2009) · International Conference on Virtual Rehabilitation · doi:10.1109/icvr.2009.5174227 · Cited by 14
Powered finger exoskeleton having partially open fingerpad for flexion force assistance
Heo, P., Kim, S. J., & Kim, J. (2013) · IEEE/ASME International Conference on Advanced Intelligent Mechatronics · doi:10.1109/aim.2013.6584089 · Cited by 14 · cited 2×
“OFX [58, 306, 307] South Korea 2013–2014 WHFO general assistance 1 Locked (FE, RUD)”
BackgroundDesign of a hand exoskeleton for biomechanical analysis of the stroke hand
Lee, J., & Bae, J. (2015) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2015.7281246 · Cited by 13
A novel, MRI compatible hand exoskeleton for finger rehabilitation
Tang, Z. J., Sugano, S., & Iwata, H. (2011) · IEEE/SICE International Symposium on System Integration (SII) · doi:10.1109/sii.2011.6147430 · Cited by 13 · cited 1×
“Tang [120–123] Japan 2011–2013 FO post-stroke measurement/therapy 1 Limited (FE)”
BackgroundReachMAN to help sub-acute patients training reaching and manipulation
Yeong, C. F., Baker, K., Melendez-Calderon, A., Burdet, E., & Playford, E. D. (2010) · IEEE Conference on Robotics, Automation and Mechatronics (RAM) · doi:10.1109/ramech.2010.5513206 · Cited by 12 · cited 1×
“ReachMAN2 [106, 176, 177] UK 2009–2014 WHFO post-stroke therapy 1 (+1 wrist) Assisted (PS) Locked (FE, RUD)”
Technical evaluation of and clinical experiences with the SCRIPT passive wrist and hand orthosis
Ateş, S., León, B., Basteris, A., Nijenhuis, S. M., Nasr, N., Sale, P., Cesario, A., Amirabdollahian, F., & Stienen, A. H. A. (2014) · Conference on Human System Interactions · doi:10.1109/hsi.2014.6860472 · Cited by 12 · cited 2×
“SPO [32, 260, 261] Netherlands 2013–2014 WHFO post-stroke therapy 0 Resisted (F), Assisted (E) Locked (RUD)”
BackgroundSelf-citationPerformance evaluations of hand and forearm support system
Hasegawa, Y., Watanabe, K., & Sankai, Y. (2010) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2010.5650355 · Cited by 12 · cited 1×
“Hasegawa [321–326] Japan 2008–2015 WHFO power assistance 8 (+ 4 wrist) Assisted (PS, FE)”
BackgroundA novel robotic assistive device for stroke-rehabilitation
McConnell, A. C., Kong, X., & Vargas, P. A. (2014) · IEEE RO-MAN · doi:10.1109/roman.2014.6926370 · Cited by 12 · cited 1×
“PMHand [175] UK 2014 HdO post-stroke therapy 1 N/A”
BackgroundBergamasco, M., Frisoli, A., Fontana, M., Loconsole, C., Leonardis, D., Troncossi, M., Foumashi, M. M., & Parenti‐Castelli, V. (2011) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975377 · Cited by 12 · cited 1×
“BRAVO Hand Exoskeleton [310–312] Italy 2011–2015 HdO post-stroke therapy/assistance 2 N/A”
BackgroundDesign of an MRI compatible robot for finger rehabilitation
Tang, Z. J., Sugano, S., & Iwata, H. (2012) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma.2012.6283177 · Cited by 11 · cited 1×
“Tang [120–123] Japan 2011–2013 FO post-stroke measurement/therapy 1 Limited (FE)”
BackgroundHioki, M., Kawasaki, H., Sakaeda, H., Nishimoto, Y., & Mouri, T. (2010) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2010.5626938 · Cited by 11 · cited 1×
“HIRO III [204] Japan 2010 HdO general physical therapy 15 N/A”
BackgroundMODEL-BASED SYSTEMS ENGINEERING OF A HAND REHABILITATION DEVICE
Patar, M. N. A. A., Komeda, T., Yee, L. C., & Mahmud, J. (2015) · Jurnal Teknologi · doi:10.11113/jt.v76.5496 · Cited by 11 · cited 2×
“Ab Patar [265, 266] Japan 2015 HdO post-stroke therapy 3 N/A”
BackgroundWatanabe, K., Morishita, H., Mori, T., & Sato, T. (2007) · Proceedings 2007 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2007.364116 · Cited by 10 · cited 3×
“From a different perspective, augmented feedback can be used to compensate for an attenuation of haptic feedback [55, 56].”
BackgroundOboe, R., Daud, O., Masiero, S., Oscari, F., & Rosati, G. (2010) · IEEE International Workshop on Advanced Motion Control (AMC) · doi:10.1109/amc.2010.5464078 · Cited by 10 · cited 1×
“NeReBot hand add-on [60, 206] Italy 2009–2010 WHFO post-stroke therapy 1 Locked (PS, FE, RUD)”
BackgroundDesign of a Grasp Assistive Glove for ADL-focused, Robotic Assisted Therapy after Stroke
Nathan, D. E., & Johnson, M. J. (2007) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428537 · Cited by 10 · cited 1×
“ADLER FES grasp glove [132, 133] USA 2007–2009 HdO post-stroke therapy Not clear Not clear”
BackgroundProposal of a SkilMate Hand and its component technologies for extravehicular activity gloves
Yamada, Y., Morizono, T., Sato, K., Shibuya, H., Shimohira, T., Umetani, Y., Yoshida, T., & Aoki, S. (2004) · Advanced Robotics · doi:10.1163/156855304322972440 · Cited by 10 · cited 2×
“SkilMate [56, 336] Japan 2001–2004 HdO power assistance 3 N/A”
BackgroundIntelligent Haptic Robotic Glove for patients diagnosed with cerebrovascular accidents
Popescu, N., Popescu, D., Poboroniuc, M.-S., & Popescu, C. D. (2013) · International Conference on System Theory, Control and Computing (ICSTCC) · doi:10.1109/icstcc.2013.6689045 · Cited by 9 · cited 1×
“IHRG [182–187] Romania 2013–2015 HdO post-stroke therapy 4 N/A”
BackgroundIPSIHAND BRAVO: An improved EEG-based brain-computer interface for hand motor control rehabilitation
Holmes, C. D., Wronkiewicz, M., Somers, T., Liu, J., Russell, E., Kim, D., Rhoades, C. E., Dunkley, J., Bundy, D. T., Galboa, E., et al. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346287 · Cited by 8
Pinching force accuracy affected by thumb sensation in human force augmentation
Hasegawa, Y., Ariyama, T., & Kamibayashi, K. (2012) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2012.6386081 · Cited by 8 · cited 1×
“Hasegawa [321–326] Japan 2008–2015 WHFO power assistance 8 (+ 4 wrist) Assisted (PS, FE)”
BackgroundDevelopment of Robotic Gloves for Hand Rehabilitation Post-Stroke
Popescu, D., Ivănescu, M., Mănoiu-Olaru, S., Popescu, L.-C., & Popescu, N. (2015) · International Conference on Control Systems and Computer Science · doi:10.1109/cscs.2015.95 · Cited by 8 · cited 1×
“IHRG [182–187] Romania 2013–2015 HdO post-stroke therapy 4 N/A”
BackgroundDevelopment of an upper limb rehabilitation robot system for bilateral training
Wei, W., Zhang, W., Guo, S., Zhao, X., & Wang, Y. (2014) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma.2014.6885822 · Cited by 7 · cited 1×
“ULERD hand module [263, 264] China 2013–2014 WHFO post-stroke therapy 1 (+2 wrist) Assisted (PS, FE) Locked (RUD)”
MethodPatar, M. N. A. A., Komeda, T., Mahmud, J., & Low, C. Y. (2015) · Lecture notes in electrical engineering · doi:10.1007/978-3-662-47200-2_11 · Cited by 7 · cited 1×
“Ab Patar [265, 266] Japan 2015 HdO post-stroke therapy 3 N/A”
BackgroundDesign and evaluation of two different finger concepts for body-powered prosthetic hand
Smit, G., Plettenburg, D. H., & van der Helm, F. C. T. (2013) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2012.12.0223 · Cited by 6 · cited 1×
“Despite this, hydraulic transmissions remain promising at similar scales [100] and are able to provide a more efficient alternative compared to a similar cable mechanism [101].”
BackgroundSelf-citationDesign and evaluation of an one DOF finger rehabilitation device
Tang, Z., Sugano, S., & Iwata, H. (2013) · IEEE/ASME International Conference on Advanced Intelligent Mechatronics · doi:10.1109/aim.2013.6584195 · Cited by 6
Design and Analysis of a Parallel Haptic Orthosis for Upper Limb Rehabilitation
Sooraj, R., Akshay, N., Jeevan, T. G., Bhavani, R. R., Vishwa, A., & Gits, S. (2013) · Cited by 6
Hasegawa, Y., & Suzuki, T. (2015) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2015.7139890 · Cited by 6 · cited 1×
“Hasegawa [321–326] Japan 2008–2015 WHFO power assistance 8 (+ 4 wrist) Assisted (PS, FE)”
BackgroundPortable and wearable five-fingered hand assistive device
Surendra, W. A., Tjahyono, A. P., & Aw, K. C. (2012) · Cited by 5
A robotic interface to train grip strength, grip coordination and finger extension following stroke
Kazemi, H., Kearney, R. E., & Milner, T. E. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346820 · Cited by 5 · cited 1×
“Kazemi [219] Canada 2012 WHFO post-stroke measurement/therapy 1 (+1 wrist) Assisted (PS)”
Robotic glove development with application in robotics rehabilitation
Popescu, D., Ivănescu, M., Mănoiu-Olaru, S., Burtea, M.-I., & Popescu, N. (2014) · International Conference and Exposition on Electrical and Power Engineering (EPE) · doi:10.1109/icepe.2014.6969890 · Cited by 4 · cited 1×
“IHRG [182–187] Romania 2013–2015 HdO post-stroke therapy 4 N/A”
BackgroundMeng, Q. Y., Tan, S. L., Yu, H. L., Meng, Q. L., & Fang, Y. F. (2014) · Applied Mechanics and Materials · doi:10.4028/www.scientific.net/amm.536-537.1015 · Cited by 3 · cited 1×
“ReHand-II [255, 256] China 2014 HdO post-stroke therapy 2 N/A”
Heo, P., & Kim, J. (2014) · IEEE Haptics Symposium · doi:10.1109/haptics.2014.6775505 · Cited by 3 · cited 2×
“OFX [58, 306, 307] South Korea 2013–2014 WHFO general assistance 1 Locked (FE, RUD)”
BackgroundDesign of a Hand Exoskeleton Rehabilitation Device
Bi, Q., & Yang, C. J. (2011) · Advanced materials research · doi:10.4028/www.scientific.net/amr.328-330.1778 · Cited by 3 · cited 1×
“Bi [159–161] China 2011–2014 WHFO post-stroke therapy 5 Locked (FE, RUD)”
Design of a Wearable Quantitative Muscle Rehabilitation Evaluation Robotic Hand Device
Tu, X., Yu, L., & He, J. M. (2012) · Lecture notes in electrical engineering · doi:10.1007/978-1-4471-2467-2_208 · Cited by 2 · cited 1×
“Wu [71, 75, 226–229] China 2008–2012 WHFO post-stroke therapy 2 Limited (PS) Locked (FE, RUD)”
Background
Cited by
Rehabilitation robots for the treatment of sensorimotor deficits: a neurophysiological perspective
Gassert, R., & Dietz, V. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0383-x · Cited by 440
Emerging Wearable Interfaces and Algorithms for Hand Gesture Recognition: A Survey
Jiang, S., Kang, P., Song, X., Lo, B., & Shull, P. (2022) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3078190 · Cited by 270
Fully Wearable Actuated Soft Exoskeleton for Grasping Assistance in Everyday Activities
Bützer, T., Lambercy, O., Arata, J., & Gassert, R. (2021) · Soft Robotics · doi:10.1089/soro.2019.0135 · Cited by 246
“…the usability in daily life include the following: Low weight and small form factor Below the suggested maximal weight of assistive hand exoskeletons, which mostly ranges between 300 and 500 g. 7,21,22 Subjects with hand impairments suggested that a weight of 200 g on the hand was ‘‘manageable.’’”
Hand Rehabilitation Robotics on Poststroke Motor Recovery
Yue, Z., Zhang, X., & Wang, J. (2017) · Behavioural Neurology · doi:10.1155/2017/3908135 · Cited by 195
“Furthermore, current reviews focus on either the hardware design of the robots or the application of specific training paradigms [23, 24], while both of them are indispensable to an efficient hand rehabilitation robot.”
BackgroundMethodInfluentialmano: A Wearable Hand Exoskeleton for Activities of Daily Living and Neurorehabilitation
Randazzo, L., Iturrate, I., Perdikis, S., & Millan, J. D. R. (2018) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2017.2771329 · Cited by 167
“Subsequent trials were separated by rest periods of random durations (in the range [3, 6] s).”
BackgroundMethod
Metadata
- Authors
- Bos, R. A., Haarman, C. J. W., Stortelder, T., Nizamis, K., Herder, J. L., Stienen, A. H. A., & Plettenburg, D. H.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2016-06-29
- Volume
- 13
- Issue
- 1
- Pages
- 62-62
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2474105065
- Cited by
- 162
- References
- 193
- FWCI
- 6.08
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.