Advances in closed-loop deep brain stimulation devices
Open accessThe DOI matches its Crossref record; 158 of the 158 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Millions of patients around the world are affected by neurological and psychiatric disorders. Deep brain stimulation (DBS) is a device-based therapy that could have fewer side-effects and higher efficiencies in drug-resistant patients compared to other therapeutic options such as pharmacological approaches. Thus far, several efforts have been made to incorporate a feedback loop into DBS devices to make them operate in a closed-loop manner. METHODS: This paper presents a comprehensive investigation into the existing research-based and commercial closed-loop DBS devices. It describes a brief history of closed-loop DBS techniques, biomarkers and algorithms used for closing the feedback loop, components of the current research-based and commercial closed-loop DBS devices, and advancements and challenges in this field of research. This review also includes a comparison of the closed-loop DBS devices and provides the future directions of this area of research. RESULTS: Although we are in the early stages of the closed-loop DBS approach, there have been fruitful efforts in design and development of closed-loop DBS devices. To date, only one commercial closed-loop DBS device has been manufactured. However, this system does not have an intelligent and patient dependent control algorithm. A closed-loop DBS device requires a control algorithm to learn and optimize the stimulation parameters according to the brain clinical state. CONCLUSIONS: The promising clinical effects of open-loop DBS have been demonstrated, indicating DBS as a pioneer technology and treatment option to serve neurological patients. However, like other commercial devices, DBS needs to be automated and modernized.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Parkinson's disease: clinical features and diagnosis
Jankovic, J. (2008) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2007.131045 · Cited by 5,720 · cited 1×
“freezing, micrographia, mask-like expression, unwanted accelerations) motor symptoms [149].”
The origin of extracellular fields and currents — EEG, ECoG, LFP and spikes
Buzsáki, G., Anastassiou, C. A., & Koch, C. (2012) · Nature Reviews Neuroscience · doi:10.1038/nrn3241 · Cited by 4,225
Frequency Dependence of Signal Power and Spatial Reach of the Local Field Potential
Leski, S., Lindén, H., Tetzlaff, T., Pettersen, K. H., & Einevoll, G. T. (2013) · PubMed · doi:10.18154/rwth-conv-084442 · Cited by 3,639
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · cited 1×
“For additional details regarding the pros and cons of each waveform refer to [89, 162] Parastarfeizabadi and Kouzani Journal of NeuroEngineering and Rehabilitation (2017) 14:79 Page 9 of 20”
BackgroundAdaptive deep brain stimulation in advanced Parkinson disease.
Little, S., Pogosyan, A., Neal, S., Zavala, B., Zrinzo, L., Hariz, M., Foltynie, T., Limousin, P., Ashkan, K., FitzGerald, J., et al. (2013) · Annals of Neurology · doi:10.1002/ana.23951 · Cited by 1,374 · cited 5×
“On the other hand, LFPs are the most used feedback signal in closed-loop DBS [3, 12, 26].”
BackgroundInfluentialWang, E.-S., Yao, H.-B., Chen, Y.-H., Wang, G., Gao, W.-W., Sun, Y.-R., Guo, J.-G., Hu, J.-W., Jiang, C.-C., & Hu, J. (2013) · Cellular Physiology and Biochemistry · doi:10.1159/000350082 · Cited by 1,176
Modelling and analysis of local field potentials for studying the function of cortical circuits
Einevoll, G. T., Kayser, C., Logothetis, N. K., & Panzeri, S. (2013) · Nature Reviews Neuroscience · doi:10.1038/nrn3599 · Cited by 857 · cited 1×
“LFPs generally have amplitudes of up to 200 μV with energies below 500 Hz [49].”
BackgroundClosed-Loop Deep Brain Stimulation Is Superior in Ameliorating Parkinsonism
Rosin, B., Slovik, M., Mitelman, R., Rivlin-Etzion, M., Haber, S. N., Israel, Z., Vaadia, E., & Bergman, H. (2011) · Neuron · doi:10.1016/j.neuron.2011.08.023 · Cited by 793 · cited 5×
“[2] demonstrated the superior function of closed-loop DBS, which automatically adjusts the stimulation parameters, to alleviate PD symptoms.”
BackgroundInfluentialBrain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
A low-power integrated circuit for a wireless 100-electrode neural recording system.
Harrison, R. R., Watkins, P. T., Kier, R. J., Lovejoy, R. O., Black, D. J., Greger, B., & Solzbacher, F. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.886567 · Cited by 782
A Low-Power Integrated Circuit for a Wireless 100-Electrode Neural Recording System
Harrison, R., Watkins, P., Kier, R., Lovejoy, R., Black, D., Normann, R., & Solzbacher, F. (2006) · 2006 IEEE International Solid State Circuits Conference - Digest of Technical Papers · doi:10.1109/isscc.2006.1696288 · Cited by 731 · cited 2×
“Typical APs recorded extracellularly have an amplitude of up to 500 μV (100 mV intracellularly [42]) with frequencies between 100 Hz - 7 kHz [43].”
BackgroundHow Local Is the Local Field Potential?
Kajikawa, Y., & Schroeder, C. E. (2011) · Neuron · doi:10.1016/j.neuron.2011.09.029 · Cited by 590 · cited 1×
“These local potentials reflect neuronal processes occurring within a local region around electrode in the neuronal extracellular space [47].”
BackgroundMechanisms of deep brain stimulation
Herrington, T. M., Cheng, J. J., & Eskandar, E. N. (2016) · Journal of Neurophysiology · doi:10.1152/jn.00281.2015 · Cited by 551 · cited 1×
“[7] accounts several non-exclusive mechanisms for DBS that depend on the condition being treated and the stimulation target.”
BackgroundVerma, N., Shoeb, A., Bohorquez, J., Dawson, J., Guttag, J., & Chandrakasan, A. P. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2042245 · Cited by 526
History, Applications, and Mechanisms of Deep Brain Stimulation
Miocinovic, S., Somayajula, S., Chitnis, S., & Vitek, J. L. (2013) · JAMA Neurology · doi:10.1001/2013.jamaneurol.45 · Cited by 496 · cited 1×
“For instance, the therapeutic response to the programming of stimulation parameters could take several weeks to finalize for depression or dystonia [71, 139], while being instantly evident for epilepsy, tremor, and PD [71].”
BackgroundSelection of stimulus parameters for deep brain stimulation
Kuncel, A. M., & Grill, W. M. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.05.031 · Cited by 458 · cited 1×
“Moreover, the neurons may get damaged because of the incorrect adjustment of the stimulation parameters [144].”
BackgroundTass, P. A. (2003) · Biological Cybernetics · doi:10.1007/s00422-003-0425-7 · Cited by 446 · cited 2×
“Occasionally, it is feasible to recapture the efficacy of openloop DBS using a coordinated reset (CR) stimulation [128, 129], which is a short-duration stimulation interval for rewiring of neuronal networks [130].”
BackgroundBasic algorithms for the programming of deep brain stimulation in Parkinson's disease
Volkmann, J., Moro, E., & Pahwa, R. (2006) · Movement Disorders · doi:10.1002/mds.20961 · Cited by 430 · cited 1×
“Using a set of guidelines, the stimulation parameters are changed based on the observable behavioral responses to the previous stimulation parameters [126].”
BackgroundBrain-Computer Interfaces Using Electrocorticographic Signals
Schalk, G., & Leuthardt, E. C. (2011) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2011.2172408 · Cited by 427 · cited 1×
“However, it suffers from low amplitude (maximum 10–20 μv [36]), low spatial resolution (~3–9 cm [37, 38]), high noise and artifacts sensitivity (e.”
BackgroundControlling Synchronization in an Ensemble of Globally Coupled Oscillators
Rosenblum, M. G., & PIKOVSKY, A. S. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.114102 · Cited by 417 · cited 1×
“These methods include single-site linear [55, 56], multi-site linear [57, 58], and non-linear [59–62] delayed feedback stimulation techniques, which intrinsically operate in a closed-loop or demand-controlled manners.”
MethodSpatial and temporal resolutions of EEG: Is it really black and white? A scalp current density view
Burle, B., Spieser, L., Roger, C., Casini, L., Hasbroucq, T., & Vidal, F. (2015) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2015.05.004 · Cited by 414 · cited 1×
“However, it suffers from low amplitude (maximum 10–20 μv [36]), low spatial resolution (~3–9 cm [37, 38]), high noise and artifacts sensitivity (e.”
BackgroundDeep brain stimulation can suppress pathological synchronisation in parkinsonian patients
Eusebio, A., Thevathasan, W., Doyle Gaynor, L., Pogosyan, A., Bye, E., Foltynie, T., Zrinzo, L., Ashkan, K., Aziz, T., & Brown, P. (2011) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2010.217489 · Cited by 412 · cited 1×
“In addition, it has been also demonstrated that DBS could suppress beta activity in off-medication state [147].”
BackgroundSignal quality of simultaneously recorded invasive and non-invasive EEG
Ball, T., Kern, M., Mutschler, I., Aertsen, A., & Schulze-Bonhage, A. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.028 · Cited by 403
Bilateral adaptive deep brain stimulation is effective in Parkinson's disease
Little, S., Beudel, M., Zrinzo, L., Foltynie, T., Limousin, P., Hariz, M., Neal, S., Cheeran, B., Cagnan, H., Gratwicke, J., et al. (2016) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp-2015-310972 · Cited by 385 · cited 1×
“[3, 76, 77] designed an on-demand adaptive DBS that digitally filters the biomarker around the beta frequency (22 Hz), generating a smoothed beta amplitude.”
BackgroundMechanism of Deep Brain Stimulation: Inhibition, Excitation, or Disruption?
Chiken, S., & Nambu, A. (2016) · The Neuroscientist · doi:10.1177/1073858415581986 · Cited by 375
Ray, N. J., Jenkinson, N., Wang, S., Holland, P., Brittain, J. S., Joint, C., Stein, J. F., & Aziz, T. (2008) · Experimental Neurology · doi:10.1016/j.expneurol.2008.05.008 · Cited by 370
Adaptive deep brain stimulation (aDBS) controlled by local field potential oscillations
Priori, A., Foffani, G., Rossi, L., & Marceglia, S. (2013) · Experimental Neurology · doi:10.1016/j.expneurol.2012.09.013 · Cited by 331 · cited 2×
“On the other hand, LFPs are the most used feedback signal in closed-loop DBS [3, 12, 26].”
BackgroundStanslaski, S., Afshar, P., Cong, P., Giftakis, J., Stypulkowski, P., Carlson, D., Linde, D., Ullestad, D., Avestruz, A.-T., & Denison, T. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2183617 · Cited by 330 · cited 4×
“The suggested device fits in a 39cm(3) space, employing front-end filtering that guarantees the op-amp input to be within its normal operation area [86].”
BackgroundMethodInfluentialEnergy harvesting for the implantable biomedical devices: issues and challenges
Hannan, M. A., Mutashar, S., Samad, S. A., & Hussain, A. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-79 · Cited by 322
Responsive Cortical Stimulation for the Treatment of Epilepsy
Sun, F. T., Morrell, M. J., & Wharen, R. E. (2008) · Neurotherapeutics · doi:10.1016/j.nurt.2007.10.069 · Cited by 309 · cited 9×
“To date, only one commercial closed-loop DBS device has been manufactured (the RNS system).”
BackgroundInfluentialDeep Brain Stimulation for the Treatment of Parkinson’s Disease
Volkmann, J. (2004) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200401000-00003 · Cited by 298 · cited 1×
“In some patients, open-loop DBS may not yield desynchronization or its therapeutic effect may decline over time [51].”
BackgroundEffective Desynchronization by Nonlinear Delayed Feedback
Popovych, O. V., Hauptmann, C., & Tass, P. A. (2005) · Physical Review Letters · doi:10.1103/physrevlett.94.164102 · Cited by 292
Rosenblum, M., & Pikovsky, A. (2004) · Physical Review E · doi:10.1103/physreve.70.041904 · Cited by 292 · cited 1×
“These methods include single-site linear [55, 56], multi-site linear [57, 58], and non-linear [59–62] delayed feedback stimulation techniques, which intrinsically operate in a closed-loop or demand-controlled manners.”
MethodHamani, C., Richter, E., Schwalb, J. M., & Lozano, A. M. (2005) · Neurosurgery · doi:10.1227/01.neu.0000159714.28232.c4 · Cited by 280 · cited 1×
“[1] stated that adjusting the stimulation * Correspondence: mparasta@deakin.”
BackgroundStimulating at the right time: phase-specific deep brain stimulation
Cagnan, H., Pedrosa, D., Little, S., Pogosyan, A., Cheeran, B., Aziz, T., Green, A., Fitzgerald, J., Foltynie, T., Limousin, P., et al. (2017) · Brain · doi:10.1093/brain/aww286 · Cited by 270 · cited 2×
“The phaseresponsive closed-loop DBS is currently being developed for treatment of tremor, aiming to selectively stimulate at the phases that attenuate the tremor amplitude through an accelerometer attached to the tremulous hand [72, 83].”
BackgroundLittle, S., & Brown, P. (2012) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2012.06650.x · Cited by 268
Bédard, C., Kröger, H., & Destexhe, A. (2004) · Biophysical Journal · doi:10.1016/s0006-3495(04)74250-2 · Cited by 264 · cited 1×
“distance, the potentials are attenuated and high-frequency components are rejected due to the low-pass filtering behavior of the brain layers [159, 160].”
BackgroundCoordinated reset has sustained aftereffects in Parkinsonian monkeys
Tass, P. A., Qin, L., Hauptmann, C., Dovero, S., Bezard, E., Boraud, T., & Meissner, W. G. (2012) · Annals of Neurology · doi:10.1002/ana.23663 · Cited by 262 · cited 1×
“results were obtained in rat hippocampal slices [132], MPTP-treated monkeys [133, 134], human PD patients [135] as well as in tinnitus patients [136, 137].”
BackgroundEngineering Complex Dynamical Structures: Sequential Patterns and Desynchronization
Kiss, I. Z., Rusin, C. G., Kori, H., & Hudson, J. L. (2007) · Science · doi:10.1126/science.1140858 · Cited by 261
Adaptive deep brain stimulation in a freely moving parkinsonian patient
Rosa, M., Arlotti, M., Ardolino, G., Cogiamanian, F., Marceglia, S., Di Fonzo, A., Cortese, F., Rampini, P. M., & Priori, A. (2015) · Movement Disorders · doi:10.1002/mds.26241 · Cited by 255 · cited 1×
“[78] presented an algorithm that continuously and linearly modifies the stimulation parameters each second according to the changes in the patient’s LFP beta power (13–17 Hz).”
BackgroundBédard, C., Kröger, H., Alain Destexhe, A., & Alain Destexhe, A. (2004) · Cited by 249
Perge, J. A., Homer, M. L., Malik, W. Q., Cash, S., Eskandar, E., Friehs, G., Donoghue, J. P., & Hochberg, L. R. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036004 · Cited by 243 · cited 1×
“Moreover, there is a need for recalibration processes to keep the stability of feedback signal [44].”
BackgroundCounteracting tinnitus by acoustic coordinated reset neuromodulation
Tass, P. A., Adamchic, I., Freund, H.-J., von Stackelberg, T., & Hauptmann, C. (2012) · Restorative Neurology and Neuroscience · doi:10.3233/rnn-2012-110218 · Cited by 240 · cited 1×
“results were obtained in rat hippocampal slices [132], MPTP-treated monkeys [133, 134], human PD patients [135] as well as in tinnitus patients [136, 137].”
BackgroundMagnetic resonance safety update 2002: Implants and devices
Shellock, F. G. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10196 · Cited by 233
A Power-Efficient Wireless System With Adaptive Supply Control for Deep Brain Stimulation
Lee, H.-M., Park, H., & Ghovanloo, M. (2013) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2266862 · Cited by 232 · cited 2×
“[91] uses the offset regulation method.”
MethodSwann, N., Poizner, H., Houser, M., Gould, S., Greenhouse, I., Cai, W., Strunk, J., George, J., & Aron, A. R. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.6135-10.2011 · Cited by 231 · cited 2×
“The cortical EEG in PD patients have shown relevance to abnormal basal ganglia circuit functions [29].”
BackgroundIn vivo impedance spectroscopy of deep brain stimulation electrodes
Lempka, S. F., Miocinovic, S., Johnson, M. D., Vitek, J. L., & McIntyre, C. C. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/4/046001 · Cited by 229 · cited 1×
“during the first 3 months following DBS surgery [95, 96] as well as post-implantation [26, 97, 98].”
BackgroundBeta oscillations in freely moving Parkinson's subjects are attenuated during deep brain stimulation
Quinn, E. J., Blumenfeld, Z., Velisar, A., Koop, M. M., Shreve, L. A., Trager, M. H., Hill, B. C., Kilbane, C., Henderson, J. M., & Brontë‐Stewart, H. (2015) · Movement Disorders · doi:10.1002/mds.26376 · Cited by 227
Coordinated reset neuromodulation for Parkinson's disease: Proof‐of‐concept study
Adamchic, I., Hauptmann, C., Barnikol, U. B., Pawelczyk, N., Popovych, O., Barnikol, T. T., Silchenko, A., Volkmann, J., Deuschl, G., Meissner, W. G., et al. (2014) · Movement Disorders · doi:10.1002/mds.25923 · Cited by 213 · cited 1×
“results were obtained in rat hippocampal slices [132], MPTP-treated monkeys [133, 134], human PD patients [135] as well as in tinnitus patients [136, 137].”
BackgroundActivity-dependent neural plasticity from bench to bedside
Ganguly, K., & Poo, M.-M. (2013) · Neuron · doi:10.1016/j.neuron.2013.10.028 · Cited by 202
Closed-Loop Control of Deep Brain Stimulation: A Simulation Study
Santaniello, S., Fiengo, G., Glielmo, L., & Grill, W. M. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2081377 · Cited by 202 · cited 1×
“[66] developed a modelbased controller through simulation of intrinsically active neurons in the Vim thalamus and getting LFPs from the neurons.”
BackgroundAdaptive Deep Brain Stimulation for Movement Disorders: The Long Road to Clinical Therapy
Meidahl, A. C., Tinkhauser, G., Herz, D. M., Cagnan, H., Debarros, J., & Brown, P. (2017) · Movement Disorders · doi:10.1002/mds.27022 · Cited by 193 · cited 4×
“In a phase responsive closed loop DBS, the stimulations are directed by the phase (timing) of the biomarker signal [72].”
BackgroundMethodInfluentialDeep Brain Stimulation Alleviates Parkinsonian Bradykinesia by Regularizing Pallidal Activity
Dorval, A. D., Kuncel, A. M., Birdno, M. J., Turner, D. A., & Grill, W. M. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00103.2010 · Cited by 174 · cited 1×
“On one hand, it has been observed that irregular stimulation patterns can reduce the beneficial therapeutic effects [92, 93].”
BackgroundDisselhorst-Klug, C., Silny, J., & Rau, G. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.594897 · Cited by 172
An active approach for charge balancing in functional electrical stimulation.
Sooksood, K., Stieglitz, T., & Ortmanns, M. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2040277 · Cited by 170 · cited 4×
“For additional details regarding the pros and cons of each waveform refer to [89, 162] Parastarfeizabadi and Kouzani Journal of NeuroEngineering and Rehabilitation (2017) 14:79 Page 9 of 20”
BackgroundMethodInfluentialControl of Neuronal Synchrony by Nonlinear Delayed Feedback
Popovych, O. V., Hauptmann, C., & Tass, P. A. (2006) · Biological Cybernetics · doi:10.1007/s00422-006-0066-8 · Cited by 167
Azin, M., Guggenmos, D. J., Barbay, S., Nudo, R. J., & Mohseni, P. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2108770 · Cited by 164 · cited 3×
“[102] proposed a closed-loop DBS device which controls the stimulator supply voltage adaptively through an inductive link.”
BackgroundAdaptive deep brain stimulation in Parkinson's disease
Beudel, M., & Brown, P. (2016) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2015.09.028 · Cited by 164 · cited 1×
“This period, known as post-operative “stun effect”, is believed to causes unrealistic outcomes as a result of temporary alleviation of PD symptoms even without stimulation [80, 81].”
BackgroundOptimal spacing of surface electrode arrays for brain–machine interface applications
Slutzky, M. W., Jordan, L. R., Krieg, T., Chen, M., Mogul, D. J., & Miller, L. E. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026004 · Cited by 161 · cited 1×
“4 mm by placing the electrode on the epidural instead of subdural space [40, 41].”
BackgroundNeurotransmitter release from high-frequency stimulation of the subthalamic nucleus
Lee, K. H., Chang, S.-Y., Roberts, D. W., & Kim, U. (2004) · Journal of Neurosurgery · doi:10.3171/jns.2004.101.3.0511 · Cited by 160
Grahn, P. J., Mallory, G. W., Khurram, O. U., Berry, B. M., Hachmann, J. T., Bieber, A. J., Bennet, K. E., Min, H.-K., Chang, S.-Y., Lee, K. H., et al. (2014) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00169 · Cited by 157
A chronic generalized bi-directional brain–machine interface
Rouse, A. G., Stanslaski, S. R., Cong, P., Jensen, R. M., Afshar, P., Ullestad, D., Gupta, R., Molnar, G. F., Moran, D. W., & Denison, T. J. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036018 · Cited by 155 · cited 1×
“techniques have been developed to tackle the impact of stimulation on biomarker recording [84, 86, 87, 146]; however, the issue has been resolved partially in the current closed-loop DBS devices.”
MethodModel of low-pass filtering of local field potentials in brain tissue
Bédard, C., Kröger, H., & Destexhe, A. (2006) · Physical Review E · doi:10.1103/physreve.73.051911 · Cited by 145 · cited 1×
“distance, the potentials are attenuated and high-frequency components are rejected due to the low-pass filtering behavior of the brain layers [159, 160].”
BackgroundA 5 $\mu$W/Channel Spectral Analysis IC for Chronic Bidirectional Brain–Machine Interfaces
Avestruz, A.-T., Santa, W., Carlson, D., Jensen, R., Stanslaski, S., Helfenstine, A., & Denison, T. (2008) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2006460 · Cited by 143
Lee, J., Rhew, H.-G., Kipke, D. R., & Flynn, M. P. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2052403 · Cited by 140 · cited 1×
“[103] developed a 64-channel programmable IC to be used as closed-loop DBS device for treatment of neurological disorders.”
MethodHigh Thalamocortical Theta Coherence in Patients with Parkinson's Disease
Sarnthein, J., & Jeanmonod, D. (2007) · Journal of Neuroscience · doi:10.1523/jneurosci.2411-06.2007 · Cited by 140 · cited 1×
“In addition, high thalamocortical theta coherence has been verified in PD patients [35].”
BackgroundSubthalamic Nucleus Stimulation: Improvements in Outcome With Reprogramming
Moro, E., Poon, Y. W., Lozano, A. M., Saint‐Cyr, J. A., & Lang, A. E. (2006) · Archives of Neurology · doi:10.1001/archneur.63.9.1266 · Cited by 139 · cited 1×
“Therefore, this could be an extra burden on clinics to employ and instruct clinical staffs to train them skills in open-loop DBS programming [140].”
BackgroundJohnson, L. A., Nebeck, S. D., Muralidharan, A., Johnson, M. D., Baker, K. B., & Vitek, J. L. (2016) · Brain stimulation · doi:10.1016/j.brs.2016.06.051 · Cited by 138 · cited 1×
“One of the concerns about the use of the beta frequency band as a feedback biomarker is that it might be affected and suppressed by movement [79].”
BackgroundRicchi, V., Zibetti, M., Angrisano, S., Merola, A., Arduino, N., Artusi, C. A., Rizzone, M. G., Lopiano, L., & Lanotte, M. (2011) · Brain stimulation · doi:10.1016/j.brs.2011.07.001 · Cited by 134 · cited 1×
“[127] observed that the gait improvement obtained by switching the stimulation frequency from 130 Hz to 80 Hz was not achievable at follow-up sessions.”
BackgroundSillay, K. A., Rutecki, P., Cicora, K., Worrell, G., Drazkowski, J., Shih, J. J., Sharan, A. D., Morrell, M. J., Williams, J., & Wingeier, B. (2013) · Brain Stimulation · doi:10.1016/j.brs.2013.02.001 · Cited by 134 · cited 1×
“during the first 3 months following DBS surgery [95, 96] as well as post-implantation [26, 97, 98].”
BackgroundHebb, A. O., Zhang, J. J., Mahoor, M. H., Tsiokos, C., Matlack, C., Chizeck, H. J., & Pouratian, N. (2013) · Neurosurgery Clinics of North America · doi:10.1016/j.nec.2013.08.006 · Cited by 133 · cited 3×
“proposed the optical and mechanical signals as other possible control signals [9].”
BackgroundInfluentialRossi, L., Foffani, G., Marceglia, S., Bracchi, F., Barbieri, S., & Priori, A. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/010 · Cited by 131 · cited 3×
“[84] designed “FilterDBS” which is an artifact-free recording system for acquisition of LFPs from the DBS lead positioned in the STN.”
BackgroundMethodAbdelhalim, K., Jafari, H. M., Kokarovtseva, L., Velazquez, J. L. P., & Genov, R. (2013) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2272952 · Cited by 124
Hauptmann, C., Popovych, O. V., & Tass, P. A. (2005) · Biological Cybernetics · doi:10.1007/s00422-005-0020-1 · Cited by 123 · cited 1×
“These methods include single-site linear [55, 56], multi-site linear [57, 58], and non-linear [59–62] delayed feedback stimulation techniques, which intrinsically operate in a closed-loop or demand-controlled manners.”
MethodClosed-loop neuromodulation systems: next-generation treatments for psychiatric illness
Lo, M.-C., & Widge, A. S. (2017) · International Review of Psychiatry · doi:10.1080/09540261.2017.1282438 · Cited by 122
The adaptive deep brain stimulation challenge
Arlotti, M., Rosa, M., Marceglia, S. R. F., Barbieri, S., & Priori, A. (2016) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2016.03.020 · Cited by 122 · cited 1×
“Ref [16] has mainly focused on selection of biomarker and its benefits and problems.”
BackgroundWang, J., Nebeck, S. D., Muralidharan, A., Johnson, M. D., Vitek, J. L., & Baker, K. B. (2016) · Brain stimulation · doi:10.1016/j.brs.2016.03.014 · Cited by 122 · cited 1×
“results were obtained in rat hippocampal slices [132], MPTP-treated monkeys [133, 134], human PD patients [135] as well as in tinnitus patients [136, 137].”
BackgroundLong-term Recordings of Local Field Potentials From Implanted Deep Brain Stimulation Electrodes
Abosch, A., Lanctin, D., Onaran, İ., Eberly, L. E., Spaniol, M., & Ince, N. F. (2012) · Neurosurgery · doi:10.1227/neu.0b013e3182676b91 · Cited by 122 · cited 2×
“during the first 3 months following DBS surgery [95, 96] as well as post-implantation [26, 97, 98].”
BackgroundTheoretical analysis of intracortical microelectrode recordings
Lempka, S. F., Johnson, M. D., Moffitt, M. A., Otto, K. J., Kipke, D. R., & McIntyre, C. C. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/045006 · Cited by 119 · cited 1×
“addition, recording from an electrode with smaller contact area enables measuring potentials from fewer neurons [161].”
BackgroundOsorio, I., Frei, M. G., Manly, B. F. J., Sunderam, S., Bhavaraju, N. C., & Wilkinson, S. B. (2001) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200111000-00003 · Cited by 115 · cited 1×
“Brief history of closed-loop DBS The review of scientific literature reveals that the initial use of closed-loop against open-loop DBS goes back to early 2000 [17] when an ultra-short-term closed-loop neurostimulator device was introduced being capable of stimulation by detection of seizures.”
BackgroundNeumann, W.-J., Huebl, J., Brücke, C., Gabriëls, L., Bajbouj, M., Merkl, A., Schneider, G.-H., Nuttin, B., Brown, P., & Kühn, A. A. (2014) · Molecular Psychiatry · doi:10.1038/mp.2014.2 · Cited by 115
Foffani, G., Ardolino, G., Egidi, M., Caputo, E., Bossi, B., & Priori, A. (2005) · Brain Research Bulletin · doi:10.1016/j.brainresbull.2005.11.012 · Cited by 113 · cited 1×
“However, the patterns of beta oscillations following DBS, differ from those after medication [148].”
BackgroundIntramedullary spinal cord neurocysticercosis presenting as Brown-Séquard syndrome
Noguera, E. M. S., Sic, R. P., & Solis, F. E. (2015) · BMC Neurology · doi:10.1186/s12883-014-0245-5 · Cited by 111
Cost‐effectiveness of deep brain stimulation in patients with Parkinson's disease
Dams, J., Siebert, U., Bornschein, B., Volkmann, J., Deuschl, G., Oertel, W. H., Dodel, R. C., & Reese, J. (2013) · Movement Disorders · doi:10.1002/mds.25407 · Cited by 106 · cited 1×
“These weaknesses can impose potential surgery risks and extra costs on patients [108].”
BackgroundFeedback suppression of neural synchrony by vanishing stimulation
Tukhlina, N., Rosenblum, M., PIKOVSKY, A. S., & Kurths, J. (2007) · Physical Review E · doi:10.1103/physreve.75.011918 · Cited by 105 · cited 2×
“In this method, suppression of neural synchrony is realized by organizing an interaction between the ensemble and a passive oscillator [63].”
BackgroundMethodSubthalamic local field potentials after seven-year deep brain stimulation in Parkinson's disease
Giannicola, G., Rosa, M., Servello, D., Menghetti, C., Carrabba, G. G., Pacchetti, C., Zangaglia, R., Cogiamanian, F. M., Scelzo, E., Marceglia, S. R. F., et al. (2012) · Experimental Neurology · doi:10.1016/j.expneurol.2012.06.012 · Cited by 104
Rhew, H.-G., Jeong, J., Fredenburg, J. A., Dodani, S., Patil, P. G., & Flynn, M. P. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2346779 · Cited by 104 · cited 2×
“While other devices take a step forward and update at least one stimulation parameter based on the biomarker state, usually pulse amplitude [86, 102, 114].”
BackgroundQasim, S. E., de Hemptinne, C., Swann, N. C., Miocinovic, S., Ostrem, J. L., & Starr, P. A. (2015) · Neurobiology of Disease · doi:10.1016/j.nbd.2015.11.023 · Cited by 104 · cited 1×
“Action potentials (APs) [2, 22], ECoGs [23, 24], LFPs [3, 12, 25–28], and electroencephalogram (EEGs) [29] are examples of electrophysiological biomarkers considered in the feedback loop of adaptive DBS systems (see Fig.”
BackgroundLin, Y.-P., Yeh, C.-Y., Huang, P.-Y., Wang, Z.-Y., Cheng, H.-H., Li, Y.-T., Chuang, C.-F., Huang, P.-C., Tang, K.-T., Ma, H.-P., et al. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2015.2403282 · Cited by 100 · cited 1×
“[115] proposed another battery-less, implantable neuro-electronic interface capable of two-way wireless telemetry.”
BackgroundChang, S.-Y., Kim, I., Marsh, M. P., Jang, D. P., Hwang, S.-C., Van Gompel, J. J., Goerss, S. J., Kimble, C. J., Bennet, K. E., Garris, P. A., et al. (2012) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2012.05.006 · Cited by 100
Long-lasting desynchronization in rat hippocampal slice induced by coordinated reset stimulation
Tass, P. A., Silchenko, A. N., Hauptmann, C., Barnikol, U. B., & Speckmann, E. ‐. (2009) · Physical Review E · doi:10.1103/physreve.80.011902 · Cited by 99 · cited 1×
“results were obtained in rat hippocampal slices [132], MPTP-treated monkeys [133, 134], human PD patients [135] as well as in tinnitus patients [136, 137].”
BackgroundBasu, I., Graupe, D., Tuninetti, D., Shukla, P., Slavin, K. V., Metman, L. V., & Corcos, D. M. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036019 · Cited by 99 · cited 1×
“Some of these devices close the feedback loop by turning the stimulation on and off known as ondemand stimulation [31, 32, 104, 141].”
BackgroundSubthalamic Nucleus Stimulation: Improvements in Outcome With Reprogramming
Moro, E. (2006) · Archives of Neurology · doi:10.1001/archneur.63.9.noc60069 · Cited by 93
The temporal pattern of stimulation may be important to the mechanism of deep brain stimulation
Hess, C. W., Vaillancourt, D. E., & Okun, M. S. (2013) · Experimental Neurology · doi:10.1016/j.expneurol.2013.02.001 · Cited by 93 · cited 1×
“[5] explained how the temporal pattern of stimulations might have key information for clarification of the DBS mechanism.”
BackgroundGorzelic, P., Schiff, S. J., & Sinha, A. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026016 · Cited by 93
Control of Abnormal Synchronization in Neurological Disorders
Popovych, O. V., & Tass, P. A. (2014) · Frontiers in Neurology · doi:10.3389/fneur.2014.00268 · Cited by 93 · cited 2×
“The outcomes confirm the robustness of CR open-loop stimulation for the treatment of neurological disorders characterized by abnormal neuronal synchronization [131].”
BackgroundLeuthardt, E. C., Freudenberg, Z., Bundy, D., & Roland, J. (2009) · Neurosurgical Focus · doi:10.3171/2009.4.focus0980 · Cited by 92 · cited 1×
“4 mm by placing the electrode on the epidural instead of subdural space [40, 41].”
BackgroundDeep brain stimulation: new techniques
Hariz, M. I. (2013) · Parkinsonism & Related Disorders · doi:10.1016/s1353-8020(13)70045-2 · Cited by 92 · cited 1×
“[10] concentrates on emerging techniques in DBS including new electrode design, new stimulation patterns, and novel targeting techniques.”
BackgroundVariation in Deep Brain Stimulation Electrode Impedance over Years Following Electrode Implantation
Satzer, D., Lanctin, D., Eberly, L. E., & Abosch, A. (2014) · Stereotactic and Functional Neurosurgery · doi:10.1159/000358014 · Cited by 91 · cited 1×
“[99] highlight a mean 73 Ω/year reduction in impedance in most electrode contacts; thus, utilizing CC devices is more preferred.”
MethodControlling synchrony in oscillatory networks with a separate stimulation-registration setup
Pyragas, K., Popovych, O. V., & Tass, P. A. (2007) · Europhysics Letters (EPL) · doi:10.1209/0295-5075/80/40002 · Cited by 91 · cited 1×
“[67] presented a demand-controlled method for suppression of neural synchrony using a proportionalintegral-derivative (PID) feedback, which enables robust restoration of desynchronized states.”
MethodOn-Demand Control System for Deep Brain Stimulation for Treatment of Intention Tremor
Yamamoto, T., Katayama, Y., Ushiba, J., Yoshino, H., Obuchi, T., Kobayashi, K., Oshima, H., & Fukaya, C. (2013) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/j.1525-1403.2012.00521.x · Cited by 90 · cited 1×
“Some of these devices close the feedback loop by turning the stimulation on and off known as ondemand stimulation [31, 32, 104, 141].”
BackgroundPulsatile desynchronizing delayed feedback for closed-loop deep brain stimulation
Popovych, O. V., Lysyansky, B., Rosenblum, M., PIKOVSKY, A. S., & Tass, P. A. (2017) · PLoS ONE · doi:10.1371/journal.pone.0173363 · Cited by 90 · cited 2×
“In recent published works [64, 65], Popovych et al.”
BackgroundPiallat, B., Chabardès, S., Devergnas, A. D., Torres-Martinez, N., Allain, M., Barrat, E., & Benabid, A. L. (2009) · Neurosurgery · doi:10.1227/01.neu.0000336331.88559.cf · Cited by 90 · cited 2×
“Being imbalanced in terms of charge yields formation of undesirable chemical reactions at the electrode contact surface over time [88].”
BackgroundNursing Time to Program and Assess Deep Brain Stimulators in Movement Disorder Patients
Hunka, K., Suchowersky, O., Wood, S. M., Derwent, L., & Kiss, Z. H. T. (2005) · Journal of Neuroscience Nursing · doi:10.1097/01376517-200508000-00006 · Cited by 88 · cited 1×
“In particular, the brain reaction to a constant set of stimulation parameters may change gradually over time due to the external (environmental) or internal (disease progress, and behavioral) factors [52, 53].”
BackgroundKupsch, A. R., Tagliati, M., Vidailhet, M., Aziz, T. Z., Krack, P., Moro, E., & Krauss, J. K. (2011) · Movement Disorders · doi:10.1002/mds.23624 · Cited by 86 · cited 1×
“In particular, the brain reaction to a constant set of stimulation parameters may change gradually over time due to the external (environmental) or internal (disease progress, and behavioral) factors [52, 53].”
BackgroundDeep Brain Stimulation: Technology at the Cutting Edge
Shah, R. S., Chang, S.-Y., Min, H.-K. P., Cho, Z., Blaha, C. D., & Lee, K. H. (2010) · Journal of Clinical Neurology · doi:10.3988/jcn.2010.6.4.167 · Cited by 86 · cited 1×
“[13] mainly reviews DBS (both open-loop and closed-loop) in terms of neurological aspects and clinical benefits.”
BackgroundTime dependent subthalamic local field potential changes after DBS surgery in Parkinson's disease
Rosa, M., Marceglia, S. R. F., Servello, D., Foffani, G., Rossi, L., Sassi, M., Mrakic‐Sposta, S., Zangaglia, R., Pacchetti, C., Porta, M., et al. (2009) · Experimental Neurology · doi:10.1016/j.expneurol.2009.12.013 · Cited by 85 · cited 1×
“during the first 3 months following DBS surgery [95, 96] as well as post-implantation [26, 97, 98].”
BackgroundAdaptive DBS in a Parkinson's patient with chronically implanted DBS: A proof of principle
Piña‐Fuentes, D., Little, S. J., Oterdoom, M., Neal, S., Pogosyan, A. H., Tijssen, M. A. J., van Laar, T., Brown, P., van Dijk, J. M. C., & Beudel, M. (2017) · Movement Disorders · doi:10.1002/mds.26959 · Cited by 84 · cited 2×
“[82] presented the first case of closed-loop DBS in a PD patient with chronic STN-DBS treatment, and concluded that closed-loop DBS can be applied in the chronically implanted DBS phase, and is at least as effective as open-loop DBS when objectively assessed [82].”
BackgroundBledsoe, J. M., Kimble, C. J., Covey, D. P., Blaha, C. D., Agnesi, F., Mohseni, P., Whitlock, S. V., Johnson, D. M., Horne, A. E., Bennet, K. E., et al. (2009) · Journal of neurosurgery · doi:10.3171/2009.3.jns081348 · Cited by 83
Chang, S.-Y., Kimble, C. J., Kim, I., Paek, S. B., Kressin, K. R., Boesche, J. B., Whitlock, S. V., Eaker, D. R., Kasasbeh, A. S., Horne, A. E., et al. (2013) · Journal of neurosurgery · doi:10.3171/2013.8.jns122142 · Cited by 79 · cited 3×
“This system records artifact-free evoked neurochemical alterations to wirelessly control the stimulation parameters [34].”
BackgroundInfluentialA Low-Power ECoG/EEG Processing IC With Integrated Multiband Energy Extractor
Zhang, F., Mishra, A., Richardson, A. G., & Otis, B. P. (2011) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2011.2163972 · Cited by 73
Deeb, W., Giordano, J. J., Rossi, P. J., Mogilner, A. Y., Gunduz, A., Judy, J. W., Klassen, B. T., Butson, C. R., van Horne, C. G., Deny, D., et al. (2016) · Frontiers in Integrative Neuroscience · doi:10.3389/fnint.2016.00038 · Cited by 73 · cited 1×
“[50], thus far several neurological disorders have been investigated with closed-loop DBS systems controlled by LFPs.”
BackgroundLettieri, C., Rinaldo, S., Devigili, G., Pauletto, G., Verriello, L., Budai, R., Fadiga, L., Oliynyk, A., Mondani, M., D’Auria, S., et al. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2012.04.027 · Cited by 71 · cited 1×
“Action potentials (APs) [2, 22], ECoGs [23, 24], LFPs [3, 12, 25–28], and electroencephalogram (EEGs) [29] are examples of electrophysiological biomarkers considered in the feedback loop of adaptive DBS systems (see Fig.”
BackgroundLongitudinal Impedance Variability in Patients with Chronically Implanted DBS Devices
Cheung, T., Nuno, M. A., Hoffman, M., Katz, M., Kilbane, C., Alterman, R. L., & Tagliati, M. (2013) · Brain stimulation · doi:10.1016/j.brs.2013.03.010 · Cited by 69 · cited 1×
“during the first 3 months following DBS surgery [95, 96] as well as post-implantation [26, 97, 98].”
BackgroundClosed-Loop Brain–Machine–Body Interfaces for Noninvasive Rehabilitation of Movement Disorders
Broccard, F. D., Mullen, T. R., Chi, Y. M., Peterson, D., Iversen, J. R., Arnold, M., Kreutz-Delgado, K., Jung, T., Makeig, S., Poizner, H., et al. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-014-1032-6 · Cited by 68 · cited 1×
“[8] mainly highlights the applications of closed-loop DBS in the rehabilitation of movement disorders.”
BackgroundSynchronization control of interacting oscillatory ensembles by mixed nonlinear delayed feedback
Popovych, O. V., & Tass, P. A. (2010) · Physical Review E · doi:10.1103/physreve.82.026204 · Cited by 68
Arlotti, M., Rossi, L., Rosa, M., Marceglia, S. R. F., & Priori, A. (2016) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2016.02.007 · Cited by 68
Tass, P. A. (2003) · Progress of Theoretical Physics Supplement · doi:10.1143/ptps.150.281 · Cited by 67 · cited 2×
“Occasionally, it is feasible to recapture the efficacy of openloop DBS using a coordinated reset (CR) stimulation [128, 129], which is a short-duration stimulation interval for rewiring of neuronal networks [130].”
BackgroundClosed loop deep brain stimulation: an evolving technology
Hosain, M. K., Kouzani, A., & Tye, S. (2014) · Australasian Physical & Engineering Sciences in Medicine · doi:10.1007/s13246-014-0297-2 · Cited by 66 · cited 2×
“[11] highlights a range of issues associated with closedloop DBS including biomarker sensing and processing, DBS parameters programming, control algorithm, wireless telemetry, and device size and power consumption.”
BackgroundSelf-citationEngineering the Next Generation of Clinical Deep Brain Stimulation Technology
McIntyre, C. C., Chaturvedi, A., Shamir, R. R., & Lempka, S. F. (2015) · Brain Stimulation · doi:10.1016/j.brs.2014.07.039 · Cited by 64
Delayed feedback control of synchronization in locally coupled neuronal networks
Hauptmann, C., Popovych, O. V., & Tass, P. A. (2004) · Neurocomputing · doi:10.1016/j.neucom.2004.10.072 · Cited by 64
Graupe, D., Basu, I., Tuninetti, D., Vannemreddy, P. S. S. V., & Slavin, K. V. (2010) · Neurological Research · doi:10.1179/016164110x12767786356354 · Cited by 63
Silchenko, A. N., Adamchic, I., Hauptmann, C., & Tass, P. A. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.03.013 · Cited by 63
Popovych, O. V., Lysyansky, B., & Tass, P. A. (2017) · Scientific Reports · doi:10.1038/s41598-017-01067-x · Cited by 63 · cited 2×
“In recent published works [64, 65], Popovych et al.”
BackgroundThe Effect of Magnetic Resonance Imagers on Implanted Neurostimulators
Gleason, C. A., Kaula, N. F., Hricak, H., Schmidt, R. A., & Tanagho, E. A. (1992) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1992.tb02904.x · Cited by 58
Griessenauer, C. J., Chang, S.-Y., Tye, S. J., Kimble, C. J., Bennet, K. E., Garris, P. A., & Lee, K. H. (2010) · Journal of neurosurgery · doi:10.3171/2010.3.jns091627 · Cited by 58
Caudate Infarcts and Hemorrhages
Venti, M. P., Paciaroni, M., & Caso, V. (2012) · Monographs in clinical neuroscience/Frontiers of neurology and neuroscience/Monographs in neural sciences · doi:10.1159/000333616 · Cited by 54
Lettieri, C., Rinaldo, S., Devigili, G., Pisa, F. E., Mucchiut, M., Belgrado, E., Mondani, M., D’Auria, S., Ius, T., Škrap, M., et al. (2014) · European Journal of Neurology · doi:10.1111/ene.12515 · Cited by 46 · cited 2×
“experiment [94], the study had some limitations as discussed in ref.”
BackgroundMethodEwing, S. G., Porr, B., Riddell, J. S., Winter, C., & Grace, A. A. (2013) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2012.12.008 · Cited by 45 · cited 3×
“SaBer DBS: a fully programmable, rechargeable, bilateral, charge-balanced preclinical microstimulator for long-term neural stimulation.”
BackgroundInfluentialAl-ani, T., Cazettes, F., Palfi, S., & Lefaucheur, J. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2011.03.022 · Cited by 45
de Noriega, F. R., Eitan, R., Marmor, O., Lavi, A., Linetzky, E., Bergman, H., & Israel, Z. H. (2015) · Stereotactic and Functional Neurosurgery · doi:10.1159/000368443 · Cited by 42
Hauptmann, C., Roulet, J.-C., Niederhauser, J. J., Döll, W., Kirlangic, M. E., Lysyansky, B., Krachkovskyi, V., Bhatti, M., Barnikol, U. B., Sasse, L., et al. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/6/066003 · Cited by 38
Su, F., Wang, J., Deng, B., Wei, X., Chen, Y., Liu, C., & Li, H. (2014) · International Journal of Neural Systems · doi:10.1142/s0129065714500300 · Cited by 37
Hilliard, J. D., Frysinger, R. C., & Elias, W. J. (2011) · Stereotactic and Functional Neurosurgery · doi:10.1159/000331269 · Cited by 37
Conceptualization and validation of an open-source closed-loop deep brain stimulation system in rat
Wu, H., Ghekiere, H., Beeckmans, D., Tambuyzer, T., van Kuyck, K., Aerts, J., & Nuttin, B. (2015) · Scientific Reports · doi:10.1038/srep09921 · Cited by 36 · cited 2×
“[4] reported that in order to obtain similar results from open-loop and closed-loop DBS, 44% less electrical stimulation is required using closed-loop DBS, which means higher efficiency, fewer surgery numbers, lower power consumption, and longer battery lifespan.”
BackgroundResultBaker, K. B., Zhang, J., & Vitek, J. L. (2011) · Experimental Neurology · doi:10.1016/j.expneurol.2011.06.012 · Cited by 35 · cited 1×
“On one hand, it has been observed that irregular stimulation patterns can reduce the beneficial therapeutic effects [92, 93].”
BackgroundExploiting pallidal plasticity for stimulation in Parkinson’s disease
Lourens, M. A. J., Schwab, B. C., Nirody, J. A., Meijer, H. G. E., & van Gils, S. A. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/2/026005 · Cited by 35 · cited 1×
“Occasionally, it is feasible to recapture the efficacy of openloop DBS using a coordinated reset (CR) stimulation [128, 129], which is a short-duration stimulation interval for rewiring of neuronal networks [130].”
BackgroundControlling Parkinson's Disease With Adaptive Deep Brain Stimulation
Little, S. J., Pogosyan, A. H., Neal, S., Zrinzo, L. U., Hariz, M. I., Foltynie, T., Limousin, P. D., & Brown, P. (2014) · Journal of Visualized Experiments · doi:10.3791/51403-v · Cited by 35 · cited 1×
“[3, 76, 77] designed an on-demand adaptive DBS that digitally filters the biomarker around the beta frequency (22 Hz), generating a smoothed beta amplitude.”
BackgroundThe study on a telemedicine interaction mode for Deep Brain Stimulation postoperative follow-up
Chen, Y., Hao, H., Chen, H., & Li, L. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318331 · Cited by 33 · cited 1×
“[119] first identified the DBS telemedicine requirements through a questionnaire responded by 22 patients and 9 neurosurgeons.”
BackgroundDeep Brain Stimulation as a New Treatment for Epilepsy
Schulze‐Bonhage, A. (2009) · Deutsches Ärzteblatt international · doi:10.3238/arztebl.2009.0407 · Cited by 33 · cited 1×
“However, due to the low specificity of seizure detection of the RNS [20], it was not entirely considered as an adaptive DBS triggered by seizures [21].”
BackgroundMiniature wireless recording and stimulation system for rodent behavioural testing
Pinnell, R., Dempster, J., & Pratt, J. A. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/6/066015 · Cited by 31 · cited 2×
“Some of these devices close the feedback loop by turning the stimulation on and off known as ondemand stimulation [31, 32, 104, 141].”
BackgroundDavidson, C. M., de Paor, A. M., Cagnan, H., & Lowery, M. M. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2475166 · Cited by 29
Michmizos, K. P., Frangou, P., Stathis, P. G., Sakas, D. E., & Nikita, K. S. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2344102 · Cited by 24
Rossi, E. G., Rosa, M., Rossi, L., Priori, A., & Marceglia, S. R. F. (2014) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2014.08.014 · Cited by 22 · cited 1×
“A web-based platform (WebBioBank) for neurophysiological DBS data collection has been developed for integration of PD clinical data [117, 118].”
MethodRF rectifiers for EM power harvesting in a Deep Brain Stimulating device
Hosain, M. K., Kouzani, A. Z., Tye, S. J., Kaynak, A., & Berk, M. (2015) · Australasian Physical & Engineering Sciences in Medicine · doi:10.1007/s13246-015-0328-7 · Cited by 20 · cited 1×
“They then proposed RF rectifiers for electromagnetic power harvesting in a DBS implant [113].”
BackgroundSelf-citationUltra Low-Power Integrated Circuit Design for Wireless Neural Interfaces
Holleman, J. H., Zhang, F., & Otis, B. P. (2010) · Springer eBooks · doi:10.1007/978-1-4419-6727-5 · Cited by 19 · cited 1×
“Typical APs recorded extracellularly have an amplitude of up to 500 μV (100 mV intracellularly [42]) with frequencies between 100 Hz - 7 kHz [43].”
BackgroundTechnology for deep brain stimulation at a gallop
Priori, A. (2015) · Movement Disorders · doi:10.1002/mds.26253 · Cited by 18 · cited 2×
“[14] introduces adaptive DBS, and outlines some technological advances in DBS including stimulation type and patterns, energy harvesting, and methods for increasing life quality of patients.”
BackgroundMethodA Miniature Low-Power Multi-Biomarker-Based Brain Sensor for Closed-Loop DBS
Parastarfeizabadi, M., & Kouzani, A. Z. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2686642 · Cited by 17 · cited 1×
“One solution is to provide the controller with multiple feedback signals [145].”
BackgroundSelf-citation64-Channel UWB wireless neural vector analyzer and phase synchrony-triggered stimulator SoC
Abdelhalim, K., Jafari, H. M., Kokarovtseva, L., Velázquez, J. L. P., & Genov, R. (2012) · European Solid-State Circuits Conference (ESSCIRC) · doi:10.1109/esscirc.2012.6341340 · Cited by 16
Paek, S. B., Knight, E. J., Chang, S.-Y., Luján, J. L., Jang, D. P., Bennet, K. E., & Lee, K. H. (2013) · Biomedical Engineering Letters · doi:10.1007/s13534-013-0086-y · Cited by 15 · cited 1×
“Furthermore, other biomarkers such as biochemical potentials need stabilization of the carbon fiber microelectrode during recording [45].”
BackgroundSimulation of PID control schemes for closed-loop deep brain stimulation
Dunn, E. M., & Lowery, M. M. (2013) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2013.6696150 · Cited by 15
A miniature closed-loop deep brain stimulation device
Parastarfeizabadi, M., Kouzani, A. Z., Gibson, I., & Tye, S. J. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591064 · Cited by 14 · cited 1×
“Some of these devices close the feedback loop by turning the stimulation on and off known as ondemand stimulation [31, 32, 104, 141].”
BackgroundSelf-citationMarceglia, S. R. F., Rossi, E. G., Rosa, M., Cogiamanian, F. M., Rossi, L., Bertolasi, L., Vogrig, A., Pinciroli, F., Barbieri, S., & Priori, A. (2015) · JMIR Research Protocols · doi:10.2196/resprot.4044 · Cited by 13 · cited 1×
“A web-based platform (WebBioBank) for neurophysiological DBS data collection has been developed for integration of PD clinical data [117, 118].”
MethodCurrent or voltage? Another Shakespearean dilemma
Beaulieu‐Boire, I., & Fasano, A. A. (2014) · European Journal of Neurology · doi:10.1111/ene.12537 · Cited by 12
Multi-layer implantable antenna for closed loop deep brain stimulation system
Hosain, M. K., Kouzani, A. Z., & Tye, S. J. (2012) · International Symposium on Communications and Information Technologies · doi:10.1109/iscit.2012.6380979 · Cited by 12
Self-citationAfshar, P., Moran, D. W., Rouse, A. G., Wei, X., & Denison, T. (2011) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2011.5910645 · Cited by 10 · cited 1×
“Action potentials (APs) [2, 22], ECoGs [23, 24], LFPs [3, 12, 25–28], and electroencephalogram (EEGs) [29] are examples of electrophysiological biomarkers considered in the feedback loop of adaptive DBS systems (see Fig.”
BackgroundZbrzeski, A., Lewis, N., Rummens, F., Jung, R., N’Kaoua, G., Benazzouz, A., & Renaud, S. (2013) · Journal of Low Power Electronics and Applications · doi:10.3390/jlpea3030279 · Cited by 6 · cited 2×
“[87] introduced an integrated neural amplifier to reduce artifacts in the recording of LFPs and spikes.”
BackgroundMethodSafety of Carbon Nanotubes for Neuronal Tissue
Bardi, G. (2012) · CRC Press eBooks · doi:10.1201/b11835-6 · Cited by 1
Cited by
Parkinson's disease: Mechanisms, translational models and management strategies
Raza, C., Anjum, R., & Shakeel, N. U. A. (2019) · Life Sciences · doi:10.1016/j.lfs.2019.03.057 · Cited by 603
Skin-inspired soft bioelectronic materials, devices and systems
Zhao, C., Park, J., Root, S. E., & Bao, Z. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00194-1 · Cited by 408
Magnetoelectric materials for miniature, wireless neural stimulation at therapeutic frequencies
Singer, A., Dutta, S., Lewis, E., Chen, Z., Chen, J. C., Verma, N., Avants, B., Feldman, A. K., O’Malley, J., Beierlein, M., et al. (2020) · Neuron · doi:10.1016/j.neuron.2020.05.019 · Cited by 202
Neuromodulation of OCD: a review of invasive and non-invasive methods
Kammen, A., Cavaleri, J., Lam, J., Frank, A. C., Mason, X., Choi, W., Penn, M., Brasfield, K., Van Noppen, B., Murray, S. B., et al. (2022) · Frontiers in Neurology · doi:10.3389/fneur.2022.909264 · Cited by 38
“Perhaps the most promising strategy to improve outcomes for a variety of pathologies is with closed-loop stimulation or adaptive stimulation (164).”
BackgroundRainey, S., & Erden, Y. J. (2020) · Science and Engineering Ethics · doi:10.1007/s11948-020-00240-2 · Cited by 32
Metadata
- Authors
- Parastarfeizabadi, M., & Kouzani, A. Z.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2017-08-11
- Volume
- 14
- Issue
- 1
- Pages
- 79-79
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2744294942
- Cited by
- 232
- References
- 158
- FWCI
- 10.58
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.