The DOI matches its Crossref record.
Functional electrical stimulation of the peroneal nerve for hemiplegia. Long-term clinical follow-up.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“for activation of lower extremity motion”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Waters et al., 1985
In the citing paper
“In spite of the fact that cuff electrodes have been implanted in patients for decades, nerves can be damaged by the presence of the cuff due to the delicacy of the nerve tissue and the physical properties of the electrodes (Nielson et al., 1976; Waters et al., 1985; Krarup et al., 1989; Naples et al., 1990; Larsen et al., 1998) , especially in peripheral nerves of the limbs, subjected to a wide”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Waters et al., 1985
In the citing paper
“In chronic neural stimulation of various peripheral nerves in humans, extraneural electrodes have proven biostable in the peroneal nerve for at least 12 years [6] in passive and active testing.”
From Safety of long-term electrical peripheral nerve stimulation: review of the state of the art (2019) · cites this paper as [6]
In the citing paper
“Waters et al. safely applied stimuli with a frequency of 33 Hz for a period of up to 12 years to the human peroneal nerve [6]”
From Safety of long-term electrical peripheral nerve stimulation: review of the state of the art (2019) · cites this paper as [6]
Citations
Cited by
Sorted by citations
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
“…for ventilatory assistance (Glenn et al., 1986; Creasey et al., 1996; Chervin and Guilleminault, 1997), for activation of lower extremity motion (Waters et al., 1985; Popovic, 1992; Haugland and Sinkjaer, 1995; Triolo et al., 1996; Graupe and Kohn, 1997; Popovic et al., 1998; Taylor et al.,…”
BackgroundInfluentialNeuromuscular electrical stimulation in neurorehabilitation
Sheffler, L. R., & Chae, J. (2007) · Muscle & Nerve · doi:10.1002/mus.20758 · Cited by 529
A spiral nerve cuff electrode for peripheral nerve stimulation
Naples, G. G., Mortimer, J. T., Scheiner, A., & Sweeney, J. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8670 · Cited by 415
Burridge, J. H., Taylor, P., Hagan, S., Wood, D., & Swain, I. (1997) · Clinical Rehabilitation · doi:10.1177/026921559701100303 · Cited by 323
Functional Electrical Stimulation and rehabilitation—an hypothesis
Rushton, D. N. (2002) · Medical Engineering & Physics · doi:10.1016/s1350-4533(02)00040-1 · Cited by 308
Stimulus waveforms for selective neural stimulation
Grill, W. M., & Mortimer, J. T. (1995) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.395310 · Cited by 291
A review of portable FES-based neural orthoses for the correction of drop foot
Lyons, G. M., Sinkjaer, T., Burridge, J. H., & Wilcox, D. J. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806832 · Cited by 277
“A follow-up study was also carried out ten years after the implant to assess the long-term performance of the implant [63].”
BackgroundClinical use of the odstock dropped foot stimulator: Its effect on the speed and effort of walking
Taylor, P. N., Burridge, J. H., Dunkerley, A. L., Wood, D. E., Norton, J. A., Singleton, C., & Swain, I. D. (1999) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(99)90333-7 · Cited by 275
Kottink, A. I. R., Oostendorp, L. J. M., Buurke, J. H., Nene, A. V., Hermens, H. J., & IJzerman, M. J. (2004) · Artificial Organs · doi:10.1111/j.1525-1594.2004.07310.x · Cited by 248
Liang, Y., Offenhäusser, A., Ingebrandt, S., & Mayer, D. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100061 · Cited by 257
Safety of long-term electrical peripheral nerve stimulation: review of the state of the art
Günter, C., Delbeke, J., & Ortiz-Catalan, M. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0474-8 · Cited by 198
Polyimide cuff electrodes for peripheral nerve stimulation
Rodri´guez, F. J., Ceballos, D., Schu¨ttler, M., Valero, A., Valderrama, E., Stieglitz, T., & Navarro, X. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00192-8 · Cited by 207
Identification of cytokine-specific sensory neural signals by decoding murine vagus nerve activity
Zanos, T. P., Silverman, H. A., Levy, T. J., Tsaava, T., Battinelli, E., Lorraine, P. W., Ashe, J. M., Chavan, S. S., Tracey, K. J., & Bouton, C. E. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1719083115 · Cited by 203
Considerations for Safety with Chronically Implanted Nerve Electrodes
Agnew, W. F., & McCreery, D. B. (1990) · Epilepsia · doi:10.1111/j.1528-1157.1990.tb05845.x · Cited by 184
Agnew, W. F., McCreery, D. B., Yuen, T. G. H., & Bullara, L. A. (1989) · Annals of Biomedical Engineering · doi:10.1007/bf02364272 · Cited by 185
“These include respiratory pacing (14,15,35), lower extremity neuromuscular assist (24,33,38,39,41), upper extremity neuromuscular assist (22), control of intractable pain (9,28,29,32,34) and electromicturition and urinary incontinence (7,31,36).”
BackgroundTong, R. K., Ng, M. F. W., & Li, L. S. (2006) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2006.06.016 · Cited by 175
Spinal Cord Microstimulation Generates Functional Limb Movements in Chronically Implanted Cats
Mushahwar, V. K. (2000) · Experimental Neurology · doi:10.1006/exnr.2000.7381 · Cited by 160
Ortiz-Catalan, M., Brånemark, R., Håkansson, B., & Delbeke, J. (2012) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-11-33 · Cited by 144
“On the clinical side, however, extra-type electrodes such as the epimysial and cuff, have proved their safety and functionality for several years in different applications [19-22,31-34,4042,52].”
BackgroundNeural network control of functional neuromuscular stimulation systems: computer simulation studies
Abbas, J. J., & Chizeck, H. J. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.469379 · Cited by 140
Quantification of recruitment properties of multiple contact cuff electrodes
Grill, W. M., & Mortimer, J. T. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.506402 · Cited by 136
A Multicenter Trial of a Footdrop Stimulator Controlled by a Tilt Sensor
Stein, R. B., Chong, S., Everaert, D. G., Rolf, R., Thompson, A. K., Whittaker, M., Robertson, J., Fung, J., Preuss, R. A., Momose, K., et al. (2006) · Neurorehabilitation and neural repair · doi:10.1177/1545968306289292 · Cited by 133
Phase II trial to evaluate the ActiGait implanted drop-foot stimulator in established hemiplegia
Burridge, J. H., Haugland, M. K., Larsen, B. T., Pickering, R., Svaneborg, N., Iversen, H. K., Pb, C., Haase, J., Brennum, J., & Sinkjær, T. (2007) · Acta Dermato Venereologica · doi:10.2340/16501977-0039 · Cited by 129
Selectivity of multiple-contact nerve cuff electrodes: a simulation analysis
Choi, A. Q., Cavanaugh, J. K., & Durand, D. M. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.909637 · Cited by 121
Ottawa Panel Evidence-Based Clinical Practice Guidelines for Post-Stroke Rehabilitation
Panel, O. (2006) · Topics in Stroke Rehabilitation · doi:10.1310/3tkx-7xec-2dtg-xqkh · Cited by 116
Abbas, J. J., & Chizeck, H. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83570 · Cited by 113
Interfaces with the Peripheral Nerve for the Control of Neuroprostheses
del Valle, J., & Navarro, X. (2013) · International Review of Neurobiology · doi:10.1016/b978-0-12-420045-6.00002-x · Cited by 105
Control of functional neuromuscular stimulation systems for standing and locomotion in paraplegics
Chizek, H. J., Kobetic, R., Marsolais, E. B., Abbas, J. J., Donner, I. H., & Simon, E. (1988) · Proceedings of the IEEE · doi:10.1109/5.9661 · Cited by 106
Functional electrical stimulation
Rushton, D. N. (1997) · Physiological Measurement · doi:10.1088/0967-3334/18/4/001 · Cited by 102
Selective activation of muscles using peripheral nerve electrodes
McNeal, D. R., & Bowman, B. R. (1985) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446866 · Cited by 97
Self-citationPeripheral Nerve Stimulation: A Review of Techniques and Clinical Efficacy
Kaye, A. D., Ridgell, S., Alpaugh, E. S., Mouhaffel, A., Kaye, A. J., Cornett, E. M., Chami, A. A., Shah, R., Dixon, B. M., Viswanath, O., et al. (2021) · Pain and Therapy · doi:10.1007/s40122-021-00298-1 · Cited by 94
Mushahwar, V. K., & Horch, K. W. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.830944 · Cited by 89
Multiple-electrode nerve cuffs for low-velocity and velocity-selective neural recording
Taylor, J. T., Donaldson, N., & Winter, J. (2004) · Medical & Biological Engineering & Computing · doi:10.1007/bf02347545 · Cited by 79
The Evolution of Neuroprosthetic Interfaces
Adewole, D. O., Serruya, M. D., Harris, J. P., Burrell, J. C., Petrov, D., Chen, H.-C. I., Wolf, J. A., & Cullen, D. K. (2016) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.2016017198 · Cited by 86
Therapeutic neural effects of electrical stimulation
Daly, J. J., Marsolais, E. B., Mendell, L. M., et al. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.547922 · Cited by 80
Chapter 2 Bidirectional Interfaces with the Peripheral Nervous System
Micera, S., & Navarro, X. (2009) · International Review of Neurobiology · doi:10.1016/s0074-7742(09)86002-9 · Cited by 69
Muscle recruitment through electrical stimulation of the lumbo-sacral spinal cord
Mushahwar, V. K., & Horch, K. W. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.830945 · Cited by 70
“organs [4]–[7].”
Bowman, B. R., & Erickson, R. C. (1985) · Annals of Biomedical Engineering · doi:10.1007/bf02371251 · Cited by 66
Autogenic EMG-controlled functional electrical stimulation for ankle dorsiflexion control
Yeom, H., & Chang, Y. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.08.011 · Cited by 66
“, 1997) may employ a ramp up and ramp down trapezoidal waveform, to more closely mimic physiologically relevant activation (Liberson et al., 1961; Waters et al., 1985).”
MethodBae, Y.-H., Ko, Y. J., Chang, W. H., et al. (2014) · Journal of Physical Therapy Science · doi:10.1589/jpts.26.1949 · Cited by 61
Gustafson, K. J., Grinberg, Y., Joseph, S. M., & Triolo, R. J. (2012) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.10.0201 · Cited by 59
“Nerve-cuff placement as far distally as possible ensures the best muscle activation selectivity; however, locations below the knee may have complications caused by lead wires crossing the joint [30].”
BackgroundA Parylene Self-Locking Cuff Electrode for Peripheral Nerve Stimulation and Recording
Yu, H., Xiong, W., Zhang, H., Wang, W., & Li, Z. (2014) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2014.2333733 · Cited by 56
“There are some reports showing that the cuff electrodes have been in use for as long as 15 years [32], [33].”
BackgroundVery Low-Noise ENG Amplifier System Using CMOS Technology
Rieger, R., Schuettler, M., Pal, D., Clarke, C., Langlois, P., Taylor, J., & Donaldson, N. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.886731 · Cited by 57
Long‐term biocompatibility of implanted polymer‐based intrafascicular electrodes
Lawrence, S. M., Larsen, J. O., Horch, K. W., Riso, R., & Sinkjær, T. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10303 · Cited by 55
An Implantable Two Channel Drop Foot Stimulator: Initial Clinical Results
Kenney, L. P. J., Bultstra, G., Buschman, R., Taylor, P. N., Mann, G. E., Hermens, H. J., Holsheimer, J., Nene, A. V., Tenniglo, M. J. B., der Aa, H. V., et al. (2002) · Artificial Organs · doi:10.1046/j.1525-1594.2002.06949.x · Cited by 56
Electrical systems for improving locomotion after incomplete spinal cord injury: an assessment.
Stein, R. B., Bélanger, M., Wheeler, G. D., Wieler, M., Popović, D. B., Procházka, A., & DAVIS, L. A. (1993) · PubMed · Cited by 56
Yarkony, G. M., Roth, E. J., Cybulski, G. R., & Jaeger, R. J. (1992) · PubMed · Cited by 53
TREATMENT OF ACQUIRED MUSCLE SPASTICITY USING PHENOL PERIPHERAL NERVE BLOCKS
Botte, M. J., Abrams, R. A., & Bodine, S. C. (1995) · Orthopedics · doi:10.3928/0147-7447-19950201-14 · Cited by 50
Functional Electrical Stimulation For Walking In Paraplegia: 17-Year Follow-Up Of 2 Cases
Agarwal, S., Kobetic, R., Nandurkar, S., & Marsolais, E. B. (2003) · The Journal of Spinal Cord Medicine · doi:10.1080/10790268.2003.11753666 · Cited by 49
Histological evaluation of polyesterimide-insulated gold wires in brain
Yuen, T. G. H., & Agnew, W. F. (1995) · Biomaterials · doi:10.1016/0142-9612(95)93121-s · Cited by 46
Lower Extremity Applications of Functional Neuromuscular Stimulation
Jaeger, R. J. (1992) · Assistive Technology · doi:10.1080/10400435.1992.10132189 · Cited by 49
Lee, I. S., Whang, C.-N., Park, J., Lee, Y., & Seo, W.-S. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00025-5 · Cited by 45
Characterization of iridium film as a stimulating neural electrode
Lee, I.-S. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00373-8 · Cited by 45
Blind source separation of peripheral nerve recordings
Tesfayesus, W., & Durand, D. M. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/s03 · Cited by 40
The development of a potential optimized stimulation intensity envelope for drop foot applications
O'Keeffe, D. T., Donnelly, A., & Lyons, G. M. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.817678 · Cited by 35
Recruitment data for nerve cuff electrodes: implications for design of implantable stimulators
McNeal, D. R., Baker, L. L., & Symons, J. T. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.19851 · Cited by 35
Self-citationMortimer, T., Agnew, W. F., Horch, K. W., Citron, P., Creasey, G. H., & Kantor, C. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.392373 · Cited by 35
Zariffa, J., Nagai, M. K., Daskalakis, Z. J., & Popović, M. R. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2023301 · Cited by 33
“The nerve cuff electrode [1]–[5] has been an essential component of this endeavour for the past 30 years, in part because it can be safely implanted for extended periods of time [6].”
BackgroundAmbulatory rehabilitation in multiple sclerosis
Kelleher, K. J., Spence, W. D., Solomonidis, S. E., & Apatsidis, D. P. (2009) · Disability and Rehabilitation · doi:10.1080/09638280902751931 · Cited by 32
“Furthermore, studies have shown that after using an FES device for a limited period, patients may acquire the ability to induce voluntary movements that were previously limited, even when the device has been turned off [82,83].”
BackgroundZanos, T. P. (2019) · Cold Spring Harbor Perspectives in Medicine · doi:10.1101/cshperspect.a034157 · Cited by 30
“Their surgical placement minimizes damage (del Valle and Navarro 2013) and they have been successfully implanted in humans (Waters et al. 1985; Tan et al. 2014).”
BackgroundFabrication of the Composite Regenerative Peripheral Nerve Interface (C-RPNI) in the Adult Rat
Svientek, S. R., Ursu, D. C., Cederna, P. S., & Kemp, S. W. P. (2020) · Journal of Visualized Experiments · doi:10.3791/60841 · Cited by 37
(2001) · PubMed · Cited by 28
Interfacing with the nervous system: a review of current bioelectric technologies
Sahyouni, R., Mahmoodi, A., Chen, J. W., Chang, D. T., Moshtaghi, O., Djalilian, H. R., & Lin, H. W. (2017) · Neurosurgical Review · doi:10.1007/s10143-017-0920-2 · Cited by 28
Kottink, A. I. R., Buschman, H. P. J., Kenney, L. P. J., Veltink, P. H., Slycke, P. J., Bultstra, G., & Hermens, H. J. (2004) · Neuromodulation Technology at the Neural Interface · doi:10.1111/j.1094-7159.2004.04213.x · Cited by 24
“The electrodes are attached to the common peroneal nerve (4,5).”
BackgroundImplantable stimulator for selective stimulation of the common peroneal nerve: a preliminary report
Rozman, J., Aćimović-Janežič, R., Tekavčič, I., Kljajić, M. V., & Trlep, M. (1994) · Journal of Medical Engineering & Technology · doi:10.3109/03091909409030228 · Cited by 25
Koh, R. G. L., Nachman, A., & Zariffa, J. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2552/14/1/016013 · Cited by 25
“Nerve cuff electrodes are a type of extraneural electrodes that have been shown to be safe for chronic implantation in humans [2]-[4] but have relatively poor recording selectivity.”
BackgroundBogataj, U., Gros, N., Kljajić, M. V., et al. (1997) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.593302 · Cited by 25
Initial results with fully implanted Neurostep TM FES system for foot drop
Ja, H., Baru, M., Bédard, S., et al. (2005) · Cited by 24
Shimada, Y., Matsunaga, T., Misawa, A., Ando, S., Itoi, E., & Konishi, N. (2006) · Neuromodulation Technology at the Neural Interface · doi:10.1111/j.1525-1403.2006.00074.x · Cited by 23
“Electrical stimulation is applied via percutaneous intramuscular electrodes surgically implanted percutaneously into the motor point of the ankle dorsiflexor muscles (11).”
MethodOrtiz-Catalan, M., Marin-Millan, J., Delbeke, J., Håkansson, B. E. V., & Brånemark, R. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-22 · Cited by 22
“Introduction Cuff electrodes have been widely used in neuroprosthetics with different applications such as footdrop correction by stimulation of the peroneal nerve in patients with hemiplegia [1]; stimulation of the median and ulnar nerves for pain control [2]; treatment of obstructive sleep apnea by stimulation of th…”
MethodMultielectrode spiral cuff for selective stimulation of nerve fibres
Rozman, J., & Trlep, M. (1992) · Journal of Medical Engineering & Technology · doi:10.3109/03091909209021983 · Cited by 21
Assessment of a two-channel implantable peroneal nerve stimulator post-stroke
Kottink, A. I. R. (2009) · doi:10.3990/1.9789036529594 · Cited by 22
BION/sup TM/. Bionic neurons for functional and therapeutic electrical stimulation
Loeb, G. E., RICHMOND, F. J. R., Olney, D., et al. (2002) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.1998.744747 · Cited by 20
Concepts and Methods in Neuromodulation and Functional Electrical Stimulation: An Introduction
Holsheimer, J. (1998) · Neuromodulation Technology at the Neural Interface · doi:10.1111/j.1525-1403.1998.tb00018.x · Cited by 19
Functional Neuromuscular Stimulation in Spinal Cord Injury
Chae, J., Kilgore, K. L., Triolo, R. J., & Creasey, G. H. (2000) · Physical Medicine and Rehabilitation Clinics of North America · doi:10.1016/s1047-9651(18)30155-4 · Cited by 18
O'Halloran, T., Haugland, M. K., Lyons, G. M., & Sinkjær, T. (2003) · Medical & Biological Engineering & Computing · doi:10.1007/bf02349978 · Cited by 18
Application of a Dual Channel Peroneal Nerve Stimulator in a Patient with a “Central” Drop Foot
van der Aa, H. E., Bultstra, G., Verloop, A. J., et al. (2002) · Springer eBooks · doi:10.1007/978-3-7091-6105-0_23 · Cited by 17
A versatile drop foot stimulator for research applications
O'Keeffe, D. T., & Lyons, G. M. (2002) · Medical Engineering & Physics · doi:10.1016/s1350-4533(02)00011-5 · Cited by 17
“Since 1961 [1], a variety of peroneal or drop foot stimulators have been developed [2–7].”
BackgroundApplied neural control in the 1990s
Heetderks, W., & Hambrecht, F. T. (1988) · Proceedings of the IEEE · doi:10.1109/5.9657 · Cited by 17
Giszter, S. F., Grill, W. M., Lemay, M. A., et al. (2000) · Frontiers in neuroscience · doi:10.1201/9781420039054.ch4 · Cited by 16
Early Intensive Neurorehabilitation in Traumatic Peripheral Nerve Injury—State of the Art
Gouveia, D., Cardoso, A., Carvalho, C., Oliveira, A. C., de Almeida, A. P., Gamboa, Ó., Lopes, B., Coelho, A. F., Alvites, R., Varejão, A. S. P., et al. (2024) · Animals · doi:10.3390/ani14060884 · Cited by 21
“Supporting this statement, Waters et al. (1985) [195] applied ES for 12 years in human patients with peroneal nerve lesions, using a frequency of 33 Hz, concluding that there was evidence of long-term safety with frequencies near 30 Hz.”
MethodAn implanted system for multi-site nerve cuff-based ENG recording using velocity selectivity
Clarke, C. T., Xu, X., Rieger, R., Taylor, J. T., & Donaldson, N. (2008) · Analog Integrated Circuits and Signal Processing · doi:10.1007/s10470-008-9233-2 · Cited by 16
Akazawa, K., Makikawa, M., Kawamura, J., et al. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.32107 · Cited by 14
Electrical Activation of Spinal Neural Circuits: Application to Motor-System Neural Prostheses
Grill, W. M. (2000) · Neuromodulation Technology at the Neural Interface · doi:10.1046/j.1525-1403.2000.00097.x · Cited by 14
Implantable neuroprosthetic technology
Bhadra, N., & Chae, J. (2009) · Neurorehabilitation · doi:10.3233/nre-2009-0500 · Cited by 12
Electrodes for Biopotential Recording and Tissue Stimulation
Button, V. L. D. S. N. (2015) · Elsevier eBooks · doi:10.1016/b978-0-12-800774-7.00002-7 · Cited by 13
Nerve cuff electrode with shape memory alloy armature: design and fabrication.
Crampon, M., Braïlovski, V., Sawan, M., & Trochu, F. (2002) · PubMed · Cited by 12
Mechanisms, Measurement, and Management of Spastic Hypertonia after Head Injury
Katz, R. T. (1992) · Physical Medicine and Rehabilitation Clinics of North America · doi:10.1016/s1047-9651(18)30648-x · Cited by 12
Sabetian, P., & Yoo, P. B. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab5551 · Cited by 11
Long‐term model of induced canine phonation
Paniello, R. C., & Dahm, J. D. (1998) · Otolaryngology · doi:10.1177/019459989811800413 · Cited by 11
Pellot-Cestero, J. E., Herring, E. Z., Graczyk, E. L., Memberg, W. D., Kirsch, R. F., Ajiboye, A. B., & Miller, J. P. (2023) · Neurosurgery · doi:10.1227/neu.0000000000002561 · Cited by 11
“24 Subsequent approaches using epineural electrodes with multiple contacts for selective stimulation of peroneal nerve fascicles showed improved ability to control inversion and eversion along with dorsi fl exion, with sustained improvements in gait.”
BackgroundStimulation of the Spinal Cord for the Control of Walking
Dalrymple, A. N., & Mushahwar, V. K. (2017) · Series on bioengineering and biomedical engineering · doi:10.1142/9789813207158_0025 · Cited by 8
Ernst, J., Grundey, J., Hewitt, M., et al. (2013) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2013-4015 · Cited by 10
RetractedModel study of time‐dependent muscle response to pulsed electrical stimulation
Joshi, R. P., Mishra, A., Xiao, S. H., & Pakhomov, A. G. (2010) · Bioelectromagnetics · doi:10.1002/bem.20566 · Cited by 10
“Such stimulation is used to activate muscles artificially and has applications in neurophysiology, clinical research, neuromuscular therapies, and fatigue reduction [Waters et al., 1985; Tanagho et al., 1989; Baker et al., 1993; Stein et al., 2002; Popovic and Thrasher, 2004].”
MethodElectrodes for the Neural Interface
Tyler, D. J., & Polasek, K. H. (2009) · Elsevier eBooks · doi:10.1016/b978-0-12-374248-3.00018-5 · Cited by 14
Procházka, A. (2018) · Comprehensive physiology · doi:10.1002/cphy.c180006 · Cited by 15
“In follow-ups, it was reported that the system continued to be used by 25 of 31 recipients for at least 7 years (192,285,319).”
A low-noise front-end for multiplexed ENG recording using CMOS technology
Taylor, J. T., & Rieger, R. (2011) · Analog Integrated Circuits and Signal Processing · doi:10.1007/s10470-011-9598-5 · Cited by 9
“Nerve cuff electrodes are currently the most well-established interfaces with safe implantation having been reported for as long as 15 years [3].”
BackgroundTherapeutic FES: From Rehabilitation to Neural Prosthetics
Campbell, J., & Meadows, P. M. (1992) · Assistive Technology · doi:10.1080/10400435.1992.10132188 · Cited by 9
Plasma processing of materials for medical applications
Lee, I. S., Park, J., & Lee, Y. (2003) · Surface and Coatings Technology · doi:10.1016/s0257-8972(03)00281-0 · Cited by 9
Sammut, S., Koh, R. G. L., & Zariffa, J. (2021) · Sensors · doi:10.3390/s21020506 · Cited by 9
A review of source separation and source localization approaches in peripheral nerves
Zariffa, J. (2014) · Asilomar Conference on Signals, Systems and Computers (ACSSC) · doi:10.1109/acssc.2014.7094448 · Cited by 10
“ratio [13], but have also been shown to be suitable for chronic implantation in humans for periods of several years [14, 15].”
Background
Metadata
- Authors
- Waters, R. L., McNeal, D. R., Faloon, W., & Clifford, B.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1985-06
- Volume
- 67
- Issue
- 5
- Pages
- 792-793
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W130055011
- Cited by
- 156
- References
- 0
- Citations by year
- 2025: 2 · 2024: 1 · 2023: 3 · 2021: 6 · 2020: 3 · 2019: 6 · 2018: 4 · 2017: 3 · 2016: 4 · 2015: 3 · 2014: 5 · 2013: 5 · 2012: 2
- FWCI
- 5.98
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Bone and Joint Surgery (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Health Sciences › Medicine › Anesthesiology and Pain Medicine › Pain Management and Treatment
- Health Sciences › Medicine › Clinical Neurology › Spinal Cord Injury Research
- Keywords
- functional electrical stimulation, peroneal nerve, hemiplegia, long-term follow-up, peripheral nerve stimulation, stroke rehabilitation
- MeSH terms
- Electric Stimulation Therapy, Follow-Up Studies, Hemiplegia, Humans, Peroneal Nerve, Time Factors, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review