CoChat

An organic NIR-II nanofluorophore with aggregation-induced emission characteristics for in vivo fluorescence imaging

Open access
Wu, Wei, Yang, Yan-Qing, Yang, Yang, Yang, Yu-Ming, Wang, Hong, Zhang, Kai-Yuan, Guo, Li, Ge, Hong-Fei, Liu, Jie, Feng, Hua · 2019 · International Journal of Nanomedicine
Cited by 52

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Abstract

Background: In vivo fluorescence imaging in the second near-infrared (NIR-II, 1000–1700 nm) window using organic fluorophores has great advantages, but generally suffers from a relatively low fluorescence quantum yield (mostly less than 2%). In this study, organic nanoparticles (L1013 NPs) with a high fluorescence quantum yield (9.9%) were systhesized for in vivo imaging. Methods: A molecule (BTPPA) with donor-acceptor-donor structure and aggregation-induced emission enabling moieties was prepared. BTPPA molecules were then encapsulated into nanoparticles (L1013 NPs) using a nanoprecipitation method. The L1013 NPs were intravenously injected into the mice (including normal, stroke and tumor models) for vascular and tumor imaging. Results: L1013 NPs excited at 808 nm exhibit NIR-II emission with a peak at 1013 nm and an emission tail extending to 1400 nm. They have a quantum yield of 9.9% and also show excellent photo/colloidal stabilities and negligible in vitro and in vivo toxicity. We use L1013 NPs for noninvasive real-time visualization of mouse hindlimb and cerebral vessels (including stroke pathology) under a very low power density (4.6–40 mW cm ‒2 ) and short exposure time (40–100 ms). Moreover, L1013 NPs are able to localize tumor pathology, with a tumor-to-normal tissue ratio of 11.7±1.3, which is unusually high for NIR-II fluorescent imaging through passive targeting strategy. Conclusion: L1013 NPs demonstrate the potential for a range of clinical applications, especially for tumor surgery. Keywords: fluorescence NIR-II imaging, aggregation-induced emission, organic nanoparticle, vascular imaging, tumor imaging

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2147/ijn.s198587

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

Metadata

Authors
Wu, W., Yang, Y.-Q., Yang, Y., Yang, Y.-M., Wang, H., Zhang, K.-Y., Guo, L., Ge, H.-F., Liu, J., & Feng, H.
Venue
International Journal of Nanomedicine
Published
2019-05
Volume
Volume 14
Pages
3571-3582
ISSN
  • 1176-9114 (ISSN-L)
  • 1178-2013
OpenAlex
W2944964319
Cited by
52
References
17
FWCI
2.95
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.