An organic NIR-II nanofluorophore with aggregation-induced emission characteristics for in vivo fluorescence imaging
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Background: In vivo fluorescence imaging in the second near-infrared (NIR-II, 1000–1700 nm) window using organic fluorophores has great advantages, but generally suffers from a relatively low fluorescence quantum yield (mostly less than 2%). In this study, organic nanoparticles (L1013 NPs) with a high fluorescence quantum yield (9.9%) were systhesized for in vivo imaging. Methods: A molecule (BTPPA) with donor-acceptor-donor structure and aggregation-induced emission enabling moieties was prepared. BTPPA molecules were then encapsulated into nanoparticles (L1013 NPs) using a nanoprecipitation method. The L1013 NPs were intravenously injected into the mice (including normal, stroke and tumor models) for vascular and tumor imaging. Results: L1013 NPs excited at 808 nm exhibit NIR-II emission with a peak at 1013 nm and an emission tail extending to 1400 nm. They have a quantum yield of 9.9% and also show excellent photo/colloidal stabilities and negligible in vitro and in vivo toxicity. We use L1013 NPs for noninvasive real-time visualization of mouse hindlimb and cerebral vessels (including stroke pathology) under a very low power density (4.6–40 mW cm ‒2 ) and short exposure time (40–100 ms). Moreover, L1013 NPs are able to localize tumor pathology, with a tumor-to-normal tissue ratio of 11.7±1.3, which is unusually high for NIR-II fluorescent imaging through passive targeting strategy. Conclusion: L1013 NPs demonstrate the potential for a range of clinical applications, especially for tumor surgery. Keywords: fluorescence NIR-II imaging, aggregation-induced emission, organic nanoparticle, vascular imaging, tumor imaging
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A small-molecule dye for NIR-II imaging
Antaris, A. L., Chen, H., Cheng, K., Sun, Y., Hong, G., Qu, C., Diao, S., Deng, Z., Hu, X., Zhang, B., et al. (2016) · Nature Materials · doi:10.1038/nmat4476 · Cited by 1,778 · cited 1×
“2 hrs (Figure 2D), which was much longer than most previously reported NIR-II fluorophores.(2,7,21,22,26) Using the NIR-II imaging system, the signals of L1013 NPs could not be detected under the concentration of 1.”
BackgroundA route to brightly fluorescent carbon nanotubes for near-infrared imaging in mice
Welsher, K., Liu, Z., Sherlock, S. P., Robinson, J. T., Chen, Z., Daranciang, D., & Dai, H. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.294 · Cited by 1,287
Multifunctional in vivo vascular imaging using near-infrared II fluorescence
Hong, G., Lee, J. C., Robinson, J. T., Raaz, U., Xie, L., Huang, N. F., Cooke, J. P., & Dai, H. (2012) · Nature Medicine · doi:10.1038/nm.2995 · Cited by 995
Welsher, K., Sherlock, S. P., & Dai, H. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1014501108 · Cited by 958
A peptide inhibitor of c-Jun N-terminal kinase protects against excitotoxicity and cerebral ischemia
Borsello, T., Clarke, P. G. H., Hirt, L., Vercelli, A., Repici, M., Schorderet, D. F., Bogousslavsky, J., & Bonny, C. (2003) · Nature Medicine · doi:10.1038/nm911 · Cited by 658
Li, B., Lu, L., Zhao, M., Lei, Z., & Zhang, F. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201801226 · Cited by 658
Hong, G., Zou, Y., Antaris, A. L., Diao, S., Wu, D., Cheng, K., Zhang, X., Chen, C., Liu, B., He, Y., et al. (2014) · Nature Communications · doi:10.1038/ncomms5206 · Cited by 563
Donor Engineering for NIR-II Molecular Fluorophores with Enhanced Fluorescent Performance
Yang, Q., Hu, Z., Zhu, S., Ma, R., Ma, H., Ma, Z., Wan, H., Zhu, T., Jiang, Z., Liu, W., et al. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.7b10334 · Cited by 554
Rational Design of Molecular Fluorophores for Biological Imaging in the NIR‐II Window
Yang, Q., Ma, Z., Wang, H., Zhou, B., Zhu, S., Zhong, Y., Wang, J., Wan, H., Antaris, A., Ma, R., et al. (2017) · Advanced Materials · doi:10.1002/adma.201605497 · Cited by 467
Self-citationA bright organic NIR-II nanofluorophore for three-dimensional imaging into biological tissues
Wan, H., Yue, J., Zhu, S., Uno, T., Zhang, X., Yang, Q., Yu, K., Hong, G., Wang, J., Li, L., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-03505-4 · Cited by 450 · cited 1×
“2 hrs (Figure 2D), which was much longer than most previously reported NIR-II fluorophores.(2,7,21,22,26) Using the NIR-II imaging system, the signals of L1013 NPs could not be detected under the concentration of 1.”
BackgroundSheng, Z., Guo, B., Hu, D., Xu, S., Wu, W., Liew, W. H., Yao, K., Jiang, J., Liu, C., Zheng, H., et al. (2018) · Advanced Materials · doi:10.1002/adma.201800766 · Cited by 445 · cited 2×
“2% based on an AIE molecule, TB1, which is similar to our BTPPA molecule, but without the presence of the octoxy chain.(39) The higher QY of L1013 NPs relative to TB1 NPs can likely be attributed to the presence of the octoxy group.”
BackgroundSelf-citationQi, J., Sun, C., Zebibula, A., Zhang, H., Kwok, R. T. K., Zhao, X., Xi, W., Lam, J. W. Y., Qian, J., & Tang, B. Z. (2018) · Advanced Materials · doi:10.1002/adma.201706856 · Cited by 418 · cited 2×
“The QY in the NIR-II region (>1000 nm) reached 6%, which was better than any previous AIE NPs.43,45 Previous studies have demonstrated that longer wavelength absorption and emission are preferentially recommended for obtaining higher imaging quality.46 In addition, L1013 NPs exhibited almost identical fluorescence int…”
BackgroundTraumatic Brain Injury Imaging in the Second Near‐Infrared Window with a Molecular Fluorophore
Zhang, X., Wang, H., Antaris, A. L., Li, L., Diao, S., Ma, R., Nguyen, A., Hong, G., Ma, Z., Wang, J., et al. (2016) · Advanced Materials · doi:10.1002/adma.201600706 · Cited by 386 · cited 1×
“2 hrs (Figure 2D), which was much longer than most previously reported NIR-II fluorophores.(2,7,21,22,26) Using the NIR-II imaging system, the signals of L1013 NPs could not be detected under the concentration of 1.”
BackgroundSelf-citationShao, W., Chen, G., Kuzmin, A., Kutscher, H. L., Pliss, A., Ohulchanskyy, T. Y., & Prasad, P. N. (2016) · Journal of the American Chemical Society · doi:10.1021/jacs.6b08973 · Cited by 386
Qi, J., Chen, C., Zhang, X., Hu, X., Ji, S., Kwok, R. T. K., Lam, J. W. Y., Ding, D., & Tang, B. Z. (2018) · Nature Communications · doi:10.1038/s41467-018-04222-8 · Cited by 350
Wang, Y., Chen, M., Alifu, N., Li, S., Qin, W., Qin, A., Tang, B. Z., & Qian, J. (2017) · ACS Nano · doi:10.1021/acsnano.7b05645 · Cited by 177
Cheng, K., Chen, H., Jenkins, C. H., Zhang, G., Zhao, W., Zhang, Z., Han, F., Fung, J., Yang, M., Jiang, Y., et al. (2017) · ACS Nano · doi:10.1021/acsnano.7b05966 · Cited by 156
Cited by
NIR‐II AIEgens: A Win–Win Integration towards Bioapplications
Xu, W., Wang, D., & Tang, B. Z. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202005899 · Cited by 457
Application of Nanomaterials in Biomedical Imaging and Cancer Therapy
Siddique, S., & Chow, J. C. L. (2020) · Nanomaterials · doi:10.3390/nano10091700 · Cited by 402
Yang, Y., Fan, X., Li, L., Yang, Y., Nuernisha, A., Xue, D., He, C., Qian, J., Hu, Q., Chen, H., et al. (2020) · ACS Nano · doi:10.1021/acsnano.0c00043 · Cited by 307
Self-citationThe Chemistry of Organic Contrast Agents in the NIR‐II Window
Mu, J., Xiao, M., Shi, Y., Geng, X., Li, H., Yin, Y., & Chen, X. (2022) · Angewandte Chemie International Edition · doi:10.1002/anie.202114722 · Cited by 305
Structural and process controls of AIEgens for NIR-II theranostics
Liu, S., Li, Y., Kwok, R. T. K., Lam, J. W. Y., & Tang, B. Z. (2021) · Chemical Science · doi:10.1039/d0sc02911d · Cited by 275
Metadata
- Authors
- Wu, W., Yang, Y.-Q., Yang, Y., Yang, Y.-M., Wang, H., Zhang, K.-Y., Guo, L., Ge, H.-F., Liu, J., & Feng, H.
- Venue
- International Journal of Nanomedicine
- Publisher
- Informa UK Limited
- Published
- 2019-05
- Volume
- Volume 14
- Pages
- 3571-3582
- ISSN
- 1176-9114 (ISSN-L)
- 1178-2013
- OpenAlex
- W2944964319
- Cited by
- 52
- References
- 17
- FWCI
- 2.95
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.