On the Analysis of Fingertip Photoplethysmogram Signals
Open accessAbstract
Photoplethysmography (PPG) is used to estimate the skin blood flow using infrared light. Researchers from different domains of science have become increasingly interested in PPG because of its advantages as non-invasive, inexpensive, and convenient diagnostic tool. Traditionally, it measures the oxygen saturation, blood pressure, cardiac output, and for assessing autonomic functions. Moreover, PPG is a promising technique for early screening of various atherosclerotic pathologies and could be helpful for regular GP-assessment but a full understanding of the diagnostic value of the different features is still lacking. Recent studies emphasise the potential information embedded in the PPG waveform signal and it deserves further attention for its possible applications beyond pulse oximetry and heart-rate calculation. Therefore, this overview discusses different types of artifact added to PPG signal, characteristic features of PPG waveform, and existing indexes to evaluate for diagnoses. Keywords: Photoplethysmography, acceleration plethysmogram, second derivative plethysmogram, digital volume pulse, ageing, artery, autonomic function, blood pressure, cardiovascular, heart rate, pulse wave analysis, vascular disease
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Figures












![Fig. (13) Typical PPG waveforms show the parameters changes with age [62].](/paper-figures/8ee5a57901c347579a7a5160e4be1526/on-the-analysis-of-fingertip-photoplethysmogram-signals-figure-13.jpg)


![Fig. (16) APG waveforms and types of photoplethysmogram [73]. There are different types of APG waveforms. The first APG waveform A (far left) refers to good circulation, whereas the amplitude of b wave is lower than c wave. The last APG waveform G (far right) refers to distinctively bad circulation, whereas the amplitude of c wave is lower than b wave.](/paper-figures/54ec3ef6e18e4116ad4a30b26f4dd445/on-the-analysis-of-fingertip-photoplethysmogram-signals-figure-16.jpg)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The shape of a clean PPG signal is closely related to the blood pulse wave of the human body25”
From Data quality evaluation in wearable monitoring (2022) · cites this paper as [25]
In the citing paper
“In this case, the pulsatile component of the PPG can be of the order of 1 mV in amplitude [55] although lower amplitudes can be caused by technical factors, such as inappropriate gain control, or physiological factors, such as vasoconstriction [9].”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [9]
In the citing paper
“In particular, obesity can lead to changes in skin thickness, blood flow, and oxygen saturation. This affects the optical properties of skin in addition to the distance light has to travel to reach a target vessel or vessels [48,59,60].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [59]
In the citing paper
“While, to the authors’ knowledge, publications that experimentally and explicitly demonstrate the effect of obesity or BMI on the PPG waveform are limited, we will explore works which suggest that there would be a substantial effect [56,59,60,61,62,63,64,65,66,67,68,69,70].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [59]
In the citing paper
“The ratio b/a has been found to correlate positively to age, while c/a, d/a and e/a have all been correlated negatively to age [29,59].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [59]
In the citing paper
“| e/a | Decrease | Takazawa et al., 1998 Elgendi et al., 2012 | [29,59] |”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [59]
In the citing paper
“| d/a | Decrease | Takazawa et al., 1998 Elgendi et al., 2012 | [29,59] |”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [59]
In the citing paper
“| c/a | Decrease | Takazawa et al., 1998 Elgendi et al., 2012 | [29,59] |”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [59]
In the citing paper
“Furthermore, PPG can be used to index heart rate variability (HRV), blood pressure, oxygen saturation, and cardiac output24, but as of yet have not be widely rolled out in consumer-use devices and therefore data collection other than HR will not be discussed further.”
From Guidelines for wrist-worn consumer wearable assessment of heart rate in biobehavioral research (2020) · cites this paper as [24]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Assessment of fat-free mass using bioelectrical impedance measurements of the human body
Lukaski, H., Johnson, P., Bolonchuk, W., & Lykken, G. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/41.4.810 · Cited by 1,896
Investigation of Chronic Venous Insufficiency: A Consensus Statement
Nicolaides, A. N. (2000) · Circulation · doi:10.1161/01.cir.102.20.e126 · Cited by 945
Fifteen years experience with finger arterial pressure monitoring: assessment of the technology
Imholz, B. P. M. (1998) · Cardiovascular Research · doi:10.1016/s0008-6363(98)00067-4 · Cited by 841
Determination of age-related increases in large artery stiffness by digital pulse contour analysis
Millasseau, S., Kelly, R. P., Ritter, J., & Chowienczyk, P. (2002) · Clinical Science · doi:10.1042/cs1030371 · Cited by 624
Takazawa, K., Tanaka, N., Fujita, M., Matsuoka, O., Saiki, T., Aikawa, M., Tamura, S., & Ibukiyama, C. (1998) · Hypertension · doi:10.1161/01.hyp.32.2.365 · Cited by 589
Photoelectric measurement of blood pressure, volume and flow in the finger
Peňáz, J. (1973) · Medical Entomology and Zoology · Cited by 528
Mobile monitoring with wearable photoplethysmographic biosensors
Asada, H. H., Shaltis, P., Reisner, A., Rhee, S., & Hutchinson, R. C. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213624 · Cited by 466
Gil, E., Orini, M., Bailón, R., Vergara, J. M., Mainardi, L., & Laguna, P. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/9/015 · Cited by 461
THE BLOOD SUPPLY OF VARIOUS SKIN AREAS AS ESTIMATED BY THE PHOTOELECTRIC PLETHYSMOGRAPH
Hertzman, A. B. (1938) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1938.124.2.328 · Cited by 455
Research works printed but not linked: 3
- [59]Takazawa KTN Fujita M Matsuoka O Saiki T Aikawa M Tamura S Ibukiyama C Assessment of vasocative agents and vascular aging by the second derivative of photoplethysmogram waveform Hypertension 1998 32 365 70 9719069
- [80]Elgendi M Jonkman M De Boer F Fred A Filipe J Gamboa h Heart Rate Variability and Acceleration Plethysmogram measured at rest Biomedical Engineering Systems and Technologies: 2011 Springer 266 77
- [81]Tokutaka H MY Gonda E Yamamoto M Construction of a General Physical Condition Judgment System Using Acceleration Plethysmogram Pulse-Wave Analysis 2009 Berlin/Heidelberg Springer 5629 307 15
Cited by
Sorted by citations
Items 901–1,000 of 1,001
Huh, Y., Noh, M., Ji, D., Oh, Y., & Sun, S. (2026) · Sensors · doi:10.3390/s26082316 · Cited by 1
Non-Contact Blood Pressure Estimation from Face Videos via Physiology-Aware Contrastive Learning
Son, J., & Choi, Y.-S. (2026) · IEEE Winter Conference on Applications of Computer Vision · doi:10.1109/wacv61042.2026.00238 · Cited by 1
Hernández-Obín, D., González-Gómez, G. H., Torres‐Machorro, A., & Lerma, C. (2026) · The European Physical Journal Special Topics · doi:10.1140/epjs/s11734-026-02373-0 · Cited by 1
Lin, C.-N., Wang, C., Chao, P.-C., Lin, J., Chang, C., Lu, H., Lin, P.-W., & Ko, P.-Y. (2026) · Frontiers in Physiology · doi:10.3389/fphys.2026.1779262 · Cited by 2
Photoplethysmography acceleration indices as digital biomarkers of cardiometabolic health
Diana, G., Otesteanu, C. F., Scardulla, F., Pasta, S., D’Acquisto, L., & Menon, C. (2026) · Frontiers in Digital Health · doi:10.3389/fdgth.2026.1910212 · Cited by 2
Design of a Real-Time Heart Rate Monitoring System Using Photoplethysmography and Smartphone
Singh, N., Prince, A., Chattopadhyay, S., Patra, R., & Mukherjee, B. (2018) · IEEE India Conference · doi:10.1109/indicon45594.2018.8987163 · Cited by 1
Time-series estimation from randomly time-warped observations
Bayram, İ. (2022) · Pattern Recognition Letters · doi:10.1016/j.patrec.2022.04.020 · Cited by 1
A NEW LOW-COMPLEXITY ALGORITHM FOR THE PULSE TRANSIT TIME EVALUATION
Lilia, R., & Omari, T. (2023) · Bioscience & Engineering An International Journal · doi:10.5121/bioej.2023.10202 · Cited by 1
Peripheral Oxygen Saturation Measurement: Could the Wrist be an Alternative Site for a Finger?
Devaki, V., Lakshmanan, M. K., & Jayanthi, T. (2023) · IEEE World Conference on Applied Intelligence and Computing (AIC) · doi:10.1109/aic57670.2023.10263821 · Cited by 1
Chou, Y., Miao, Y., Sun, Y., Chou, L., Zhou, Y., & An, A. (2023) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2023.104085 · Cited by 1
Ammar, M. M., Said, N. M. B., Said, Y. N. B., Abdel-Salam, A., Levushkin, S. P., Laptev, A. I., Inoubli, M., & Chlif, M. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13195990 · Cited by 1
Choi, H.-J., & Um, J. (2025) · IEEE Access · doi:10.1109/access.2025.3540440 · Cited by 1
Smart Adaptive Lighting Based on Determination of Human Healthy and Circadian Rhythms
Zheliazkov, Y., Yamnenko, I., & Globa, L. S. (2025) · Lecture notes in networks and systems · doi:10.1007/978-3-031-89296-7_23 · Cited by 1
Dehghandar, M., Nikbakht, M., & Nadarabadi, F. Y. (2025) · Journal of Health and Biomedical Informatics · doi:10.34172/jhbmi.2025.02 · Cited by 1
Mohammadi, H., Tarvirdizadeh, B., Alipour, K., & Ghamari, M. (2025) · Health Informatics Journal · doi:10.1177/14604582251406449 · Cited by 1
Non-Invasive Blood Pressure Estimation Enhanced by Capillary Refill Time Modulation of PPG Signals
Yin, Q., Chen, Y., Lin, L., Wang, D., & Sun, S. (2026) · Sensors · doi:10.3390/s26010345 · Cited by 1
Szőnyi, M. D., Gausz, F. D., Bocz, B., Pilecky, D., Muk, B., Bánfi‐Bacsárdi, F., Földesi, C., Andreka, P. G., Szili‐Törok, T., Kupó, P., et al. (2026) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztag009 · Cited by 1
Mather, J. D., Sculthorpe, N. F., Berry, E. C. J., Mair, J. L., Sanal‐Hayes, N. E. M., & Hayes, L. D. (2026) · JMIR Research Protocols · doi:10.2196/84837 · Cited by 1
Msokar, S., & Davydov, R. V. (2026) · doi:10.1109/elcon-cn69892.2026.11414048 · Cited by 1
Hernández-Obín, D., Torres‐Machorro, A., & Lerma, C. (2026) · Sensors · doi:10.3390/s26061864 · Cited by 1
Effect of heat exposure on pulse wave dynamics using pulse rate variability
Akanksha, K., Reyes-Lagos, J. J., Aggarwal, Y., & Sinha, R. K. (2026) · Stress · doi:10.1080/10253890.2026.2643515 · Cited by 1
Wearable ECG and PPG for anxiety detection: a translational digital medicine perspective
Elgendi, M., Elkhalifa, A., Alhashmi, N., Aldahmani, A., Aljneibi, N., Alamro, D., Jelinek, H. F., Khandoker, A. H., & Ward, R. K. (2026) · npj Digital Medicine · doi:10.1038/s41746-026-02620-7 · Cited by 2
Self-citationKim, B. K., Jee, S., Ahn, Y., Lee, I. S., Kim, D., Park, S., Jung, Y., Bae, I., & Baek, S. (2026) · Advanced Science · doi:10.1002/advs.202524375 · Cited by 1
Wang, S., Laforet, J., Rida, I., Druart, B., Becheler, A., Istrate, D., & Boudaoud, S. (2026) · Journal of Visual Communication and Image Representation · doi:10.1016/j.jvcir.2026.104840 · Cited by 1
PhysQual: A quality-aware learning framework for robust remote photoplethysmography
Mohamad, F., Zulkernine, F. H., & Sears, K. (2026) · Smart Health · doi:10.1016/j.smhl.2026.100683 · Cited by 1
Notice of Removal Emotion evaluations by using pulse oximeter
Muraki, S., & Suzuki, A. (2015) · Annual Conference of the Society of Instrument and Control Engineers of Japan (SICE) · doi:10.1109/sice.2015.7285524 · Cited by 1
Photoplethysmographic Heart Rate and Blood Pressure Estimation in Dynamic Condition
Zazula, D., Pirš, C., Benkic, K., Đonlagić, D., & Cigale, B. (2014) · Cited by 1
Paradkar, N., & Chowdhury, S. R. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6943528 · Cited by 1
Bozkurt, F., Bozkurt, M. R., Uçar, M. K., Bílgín, C., & Köklükaya, E. (2016) · Signal Processing and Communications Applications Conference (SIU) · doi:10.1109/siu.2016.7495890 · Cited by 1
A Cluster Method to Noninvasive Continuous Blood Pressure Measurement Using PPG
Yu, M., Zhang, Z., Meng, L., Xie, X., & Pan, H. (2017) · Lecture notes in computer science · doi:10.1007/978-3-319-59858-1_11 · Cited by 1
Non Invasive Cardiovascular Health Assessment in Post-adolescent Age Group Using Augmentation Index
Karun, S., Nath, S. S., Bharathi, K., Gaonkar, M., & Krupa, B. (2017) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-981-10-7554-4_2 · Cited by 1
Zhao, A., Chong, Y., Zhong, H., Ma, J., Zhang, H., Luo, Z., Li, G., & Luo, X. (2017) · IEEE International Conference on Bioinformatics and Bioengineering (BIBE) · doi:10.1109/bibe.2017.00008 · Cited by 1
Let home nursing assistant robots see your heart rate
Wu, H., Wang, T., Dai, T., Wang, X., Lin, Y., & Wang, Y. (2018) · International Journal of Crowd Science · doi:10.1108/ijcs-09-2018-0023 · Cited by 1
Modern Healthcare With Wearable Sensors and Wireless Technology
Mary, X. A., Jegan, R., & Evangeline, C. S. (2020) · Advances in medical technologies and clinical practice book series · doi:10.4018/978-1-5225-6067-8.ch013 · Cited by 1
Tang, S., Luo, X., Meng, S., Wang, Z., & Zhao, A. (2020) · IEEE International Conference on Bioinformatics and Bioengineering (BIBE) · doi:10.1109/bibe50027.2020.00047 · Cited by 1
Villa, A. D. (2021) · IEEE International Symposium on Electronics and the Environment (ISEE) · doi:10.1109/isee51682.2021.9418794 · Cited by 1
Seldon, H. L., Theng, L. B., & Ong, Y. L. (2020) · EAI International Conference on Mobile and Ubiquitous Systems: Computing, Networking and Services (MobiQuitous) · doi:10.1145/3448891.3448951 · Cited by 1
Kel’manov, A. V., Mikhailova, L. V., Ruzankin, P., & Khamidullin, S. A. (2021) · Computational Mathematics and Mathematical Physics · doi:10.1134/s0965542521070095 · Cited by 1
Linares, P., Bautista, D. M., & Prado, S. (2021) · IEEE Eurasia Conference on IOT, Communication and Engineering (ECICE) · doi:10.1109/ecice52819.2021.9645708 · Cited by 1
Photoplethysmographic Waveforms Analysis and Classification
Dykyy, A., Vountesmery, Y., Мамилов, С. А., & Chaikovsky, I. A. (2022) · IEEE International Conference on Electronics and Nanotechnology (ELNANO) · doi:10.1109/elnano54667.2022.9927083 · Cited by 1
Preprocessing and Mathematical Analysis of PPG Signals
Georgieva-Tsaneva, G. N. (2022) · Innovative STEM Education · doi:10.55630/stem.2022.0407 · Cited by 1
Photoplethysmography Sensors Concept and Advancements: A Review
Shiralkar, S., Bahulekar, A., Dhumal, S., & Razdan, S. (2022) · IEEE Pune Section International Conference (PuneCon) · doi:10.1109/punecon55413.2022.10014908 · Cited by 1
Wang, W., & Najafizadeh, L. (2022) · Asilomar Conference on Signals, Systems and Computers (ACSSC) · doi:10.1109/ieeeconf56349.2022.10051933 · Cited by 1
Zhang, X. M., Xu, Y., Li, Y., Shan, J., Hu, T., Gao, L., Sun, Y., Chen, M., Zhao, X., & Ma, Z. (2023) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2023.105088 · Cited by 1
Lu, C.-G., & Wang, L. (2023) · IEEE International Conference on Electronic Communications, Internet of Things and Big Data (ICEIB) · doi:10.1109/iceib57887.2023.10170050 · Cited by 1
A Flexible and Ultra-Thin Ultrasonic Sensor for Continuous Carotid Pulse Wave Monitoring
Xie, Y., Cui, T., Zhao, Y., Yang, S., Yang, Y., & Ren, T. (2023) · IEEE International Conference on Nanotechnology (IEEE-NANO) · doi:10.1109/nano58406.2023.10231191 · Cited by 1
Review of the current diagnostic techniques for deep vein thrombosis
Uday, K., & Mudigonda, M. (2024) · AIP conference proceedings · doi:10.1063/5.0196236 · Cited by 1
Prediction of Noise-Type and its Elimination from Photoplethysmograph Signal
Chowdhury, S., Bose, A., Mukherjee, S., & Chandra, J. K. (2024) · International Conference on Control, Instrumentation, Energy & Communication · doi:10.1109/ciec59440.2024.10468270 · Cited by 1
Lapitan, D. G., Tarasov, A. P., & Рогаткин, Д. А. (2024) · Meditsinskaya Fizika · doi:10.52775/1810-200x-2024-101-1-44-52 · Cited by 1
Design and Implementation of Low Power Oximeter
Pathak, A., Goel, V., Pandey, A., & Bansal, U. (2024) · International Conference on Device Intelligence, Computing and Communication Technologies (DICCT) · doi:10.1109/dicct61038.2024.10532979 · Cited by 1
LSTM Model for Sepsis Detection and Classification Using PPG Signals
Alvarez-Navarro, M. A., Huallparimachi, L., Cruz-Romero, S. A., & Sierra, H. (2024) · Lecture notes in networks and systems · doi:10.1007/978-3-031-67447-1_1 · Cited by 2
Narasimharao, M., Swain, B., Nayak, P. P., & Bhuyan, S. (2024) · Odisha International Conference on Electrical Power Engineering, Communication and Computing Technology (ODICON) · doi:10.1109/odicon62106.2024.10797580 · Cited by 1
Divya, R., Vanathi, P. T., & Harikumar, R. (2024) · THE SCIENTIFIC TEMPER · doi:10.58414/scientifictemper.2024.15.3.70 · Cited by 1
Telangore, H., Tripathi, K., Vyas, K., Sharma, M. D., Sharma, Y., Joshi, D., Tan, R., & Acharya, R. (2026) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2026.111105 · Cited by 1
Pulse wave travel distance as a novel marker of ventricular-arterial coupling
Obata, Y., Ruzankin, P., Gottschalk, A., Nyhan, D. P., Berkowitz, D. E., Steppan, J., & Barodka, V. M. (2017) · Heart and Vessels · doi:10.1007/s00380-017-1058-4 · Cited by 1
Auralife Instant Blood Pressure App in Measuring Resting Heart Rate: Validation Study
Plante, T. B., O’Kelly, A. C., Urrea, B., MacFarlane, Z. T., Appel, L. J., Miller, E. R., Blumenthal, R. S., & Martin, S. S. (2018) · JMIR Biomedical Engineering · doi:10.2196/11057 · Cited by 1
Variational-statistical and spectral analysis of photoplethysmograms
Isupov, I. B., & Zatrudina, R. S. (2019) · Saratov Fall Meeting: Computations and Data Analysis: from Nanoscale Tools to Brain Functions (SFM) · doi:10.1117/12.2523349 · Cited by 1
A novel method for determining a newborn baby's identity based on fingerprints
Lalović, K., Tot, I., & Trikoš, M. (2019) · Vojnotehnicki glasnik · doi:10.5937/vojtehg67-18709 · Cited by 1
Królak, A., & Biskupiak, J. (2019) · Advances in intelligent systems and computing · doi:10.1007/978-3-030-29885-2_1 · Cited by 1
Photoplethysmographic Waveform in Hyperbaric Environment
Peláez‐Coca, M. D., Hernando, A., Sánchez, C., Lozano, M. T., Izquierdo, D., & Gil, E. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8856400 · Cited by 1
Pulse Wave Characteristics Based on Age and Body Mass Index (BMI) During Sitting Posture
Heydari, F., Ebrahim, M. P., Redouté, J., & Yuce, M. R. (2019) · Lecture notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering · doi:10.1007/978-3-030-34833-5_11 · Cited by 1
The hypertension groove auricular acupoint modifies pulse transit time in healthy subjects
Rivas-Vilchis, J. F., & Castañeda-Ramírez, M. S. (2019) · Revista Internacional de Acupuntura · doi:10.1016/j.acu.2019.10.005 · Cited by 1
Button, V. L. D. S. N. (2015) · Elsevier eBooks · doi:10.1016/b978-0-12-800774-7.00007-6 · Cited by 1
Telemed noninvasive glucose blood level measuring by near infrared light
Piyapan, S., Krachaechuang, M., Samakit, T., Somboonwong, T., Srininrat, K., & Naiyanertr, P. (2020) · International Electrical Engineering Congress (iEECON) · doi:10.1109/ieecon48109.2020.229531 · Cited by 1
Draft Proposal of an Optical Cuffless Blood Pressure Device
TAMURA, T. (2020) · Health and Technology · doi:10.1007/s12553-020-00435-4 · Cited by 1
Expanding of Intellectual Possibilities of Digital Tonometers for Home Using
Fainzilberg, L. S. (2020) · Control Systems and Computers · doi:10.15407/csc.2020.01.060 · Cited by 1
Kel’manov, A. V., Mikhailova, L. V., Ruzankin, P., & Khamidullin, S. A. (2020) · Numerical Analysis and Applications · doi:10.1134/s1995423920020020 · Cited by 1
Rasid, M. H. M., Simon, N. L., & Adam, A. (2020) · International Conference on Biomedical Engineering and Technology (ICBET) · doi:10.1145/3397391.3397394 · Cited by 1
Analysis of Source-to-Area Distance in PPG Signal Detection Using Phototransistor
Martinez-Ojeda, C. O., & Cruz, J. C. D. (2020) · IEEE International Conference on Automatic Control and Intelligent Systems (I2CACIS) · doi:10.1109/i2cacis49202.2020.9140101 · Cited by 1
Novel Catheter Multiscope: A Feasibility Study
Adithya, P. C., Hart, S. R., Tejada‐Martínez, A., Moreno, W. A., & Sankar, R. T. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.3009361 · Cited by 1
Mikhailova, L. V., & Khamidullin, S. A. (2020) · Lecture notes in computer science · doi:10.1007/978-3-030-62867-3_16 · Cited by 1
Problem of Minimizing a Sum of Differences of Weighted Convolutions
Kel’manov, A. V., Mikhailova, L. V., Ruzankin, P., & Khamidullin, S. A. (2020) · Computational Mathematics and Mathematical Physics · doi:10.1134/s0965542520120052 · Cited by 1
Detection of special points in a photoplethysmogram
Gribkov, V. Y., Igor, I., & Zatrudina, R. S. (2021) · Saratov Fall Meeting: Computations and Data Analysis: from Nanoscale Tools to Brain Functions (SFM) · doi:10.1117/12.2591113 · Cited by 1
AIM and Transdermal Optical Imaging
Barszczyk, A., Zhou, W., & Lee, K. (2021) · Springer eBooks · doi:10.1007/978-3-030-58080-3_250-1 · Cited by 1
G., S. M., & Pandian, P. S. (2022) · International Journal of Biomedical and Clinical Engineering · doi:10.4018/ijbce.290387 · Cited by 1
CardiaPPG - A Portable, Low-Cost Photopletismograph for the Evaluation of the Cardiovascular Age
Comai, S., Masciadri, A., Monasterio, F., Motetta, F., Pozzi, G., & Salice, F. (2023) · IEEE International Conference on Digital Health (ICDH) · doi:10.1109/icdh60066.2023.00040 · Cited by 1
Gama, C. (2015) · City Research Online (City University London) · Cited by 1
Automatic Feature Extraction in Accelerated Plethysmography
Bansal, S., & Singh, M. (2014) · Cited by 1
Pitta Detection Using Second Derivative Features of Finger Photo-Plethysmogram
Nagpal, S., & Singh, M. (2013) · Cited by 1
Detection of c, d, and e Waves in the Acceleration PhotoplethysmogramPreprint
Elgendi, M. (2013) · viXra · Cited by 1
Self-citationMedidas ópticas não invasivas de tempo de resposta da perfusão sanguínea
de Souza, R. P. (2020) · doi:10.11606/d.59.2020.tde-22072020-165223 · Cited by 1
Continuous Monitoring of Blood Pressure with Evidential RegressionPreprint
Kim, H., Kang, W. H., Lee, H., & Kim, N. S. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2102.03542 · Cited by 1
A contribution to unobtrusive video-based measurement of respiratory signals
Mateu-Mateus, M. (2020) · doi:10.5821/dissertation-2117-334684 · Cited by 1
Data-driven methods for analyzing ballistocardiograms in longitudinal cardiovascular monitoring
Enayati, M. (2019) · doi:10.32469/10355/72208 · Cited by 1
Prada, E. J. A., & Mosquera, C. D. C. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4797403 · Cited by 1
Mather, J. D., Sculthorpe, N. F., Sanal‐Hayes, N. E. M., Berry, E. C. J., Mair, J. L., & Hayes, L. D. (2025) · medRxiv · doi:10.1101/2025.06.13.25329618 · Cited by 1
Choudhary, T., Hassanuzzaman, M., Krishnan, P., Ali, A., Moas, V. M., & Kamaleswaran, R. (2026) · Research Square · doi:10.21203/rs.3.rs-8419239/v1 · Cited by 1
Can Heart Rate Variability (HRV) be Determined Using Short-Term Photoplethysmograms?Preprint
Elgendi, M., Norton, I., Brearley, M. B., Dokos, S., Abbott, D., & Schuurmans, D. (2013) · viXra
Self-citationMultichannel module characterization of optical sensors employed in photoplethysmography
Timimi, A. Y. K., & Ali, M. A. M. (2014) · IEEE/CPMT International Electronics Manufacturing Technology Symposium · doi:10.1109/iemt.2014.7123144
Four channel device for PPG measurements
Borik, Š., Čáp, I., & Babušiak, B. (2015) · International Conference on Telecommunications and Signal Processing (TSP) · doi:10.1109/tsp.2015.7296297
Heart Rate Detection from Photoplethysmography- A Comparative Study
Satapathi, P. R., & Saha, P. (2015)
The development of human biometric identification using acceleration plethysmogram
Sidek, K. A., Zainal, N. I., Azam, S. N. A. M., & Jaafar, N. A. L. (2015) · The International Islamic University Malaysia Repository (The International Islamic University Malaysia)
Computerized Optical Plethysmography for Data Recording and Processing of Biomedical Signal
Sasono, M., & Praja, A. R. I. (2016) · International Journal of Engineering Research and · doi:10.17577/ijertv5is020608
Determination of Oxygen Saturation and Photoplethysmogram from Near Infrared Scattering ImagesPreprint
Ri, Y.-U., Pyon, Y.-H., & Sin, K.-R. (2016) · arXiv (Cornell University) · doi:10.48550/arxiv.1604.06855
Detekcja błędów segmentacji sygnału fotopletyzmograficznego
Bołtrukiewicz, M. (2014) · Pomiary Automatyka Kontrola
Determination of Heart Rate and Arterial Stiffness using LabVIEW and MatLab
Begum, N., & Bordoloi, H. (2016) · ADBU - journal of engineering and technology
Development of an Acceleration Plethysmogram based Cardioid Graph Biometric Identification
Sidek, K. A., Osman, M., Azam, S. N. A. M., & Zainal, N. I. (2016) · International Journal of Bio-Science and Bio-Technology · doi:10.14257/ijbsbt.2016.8.3.02
Development of a Photoplethysmogram Based Heart Abnormality Detection Technique
Umadi, L. F., Azam, S. N. A. M., & Sidek, K. A. (2016) · International Journal of Bio-Science and Bio-Technology · doi:10.14257/ijbsbt.2016.8.4.10
Kamarul, A. B. (2016) · IEEE-EMBS Conference on Biomedical Engineering and Sciences · doi:10.1109/iecbes.2016.7843501
Metadata
- Authors
- Elgendi, M.
- Affiliations
- Charles Darwin University (AU)
- Corresponding author
- Elgendi, Mohamed
- ORCID
- Elgendi, Mohamed
- Venue
- Current Cardiology Reviews
- Publisher
- Bentham Science Publishers Ltd.
- Published
- 2012-06-01
- Volume
- 8
- Issue
- 1
- Pages
- 14-25
- ISSN
- 1573-403X (ISSN-L)
- PMC
- PMC3394104
- OpenAlex
- W1981918735
- Cited by
- 1,206
- References
- 88
- Citations by year
- 2026: 120 · 2025: 106 · 2024: 116 · 2023: 109 · 2022: 130 · 2021: 114 · 2020: 118 · 2019: 118 · 2018: 86 · 2017: 65 · 2016: 46 · 2015: 42 · 2014: 24 · 2013: 11 · 2012: 1
- FWCI
- 2.17
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Current Cardiology Reviews (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DR-NTU (Nanyang Technological University) (submittedVersion)
- Funders
- Univerzita Karlova v Praze
- Australian Government
- Charles Darwin University
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- photoplethysmography, digital volume pulse, aging, autonomic function, blood pressure, heart rate, pulse wave analysis, cardiovascular disease, vascular disease, atherosclerosis screening
- MeSH terms
- Fingers, Hemodynamics, Humans, Skin, Artifacts, Photoplethysmography, Pulse Wave Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review