The DOI matches its Crossref record; 85 of the 88 references it cites were found in a registry or an index.
On the Analysis of Fingertip Photoplethysmogram Signals
Open accessAbstract
Photoplethysmography (PPG) is used to estimate the skin blood flow using infrared light. Researchers from different domains of science have become increasingly interested in PPG because of its advantages as non-invasive, inexpensive, and convenient diagnostic tool. Traditionally, it measures the oxygen saturation, blood pressure, cardiac output, and for assessing autonomic functions. Moreover, PPG is a promising technique for early screening of various atherosclerotic pathologies and could be helpful for regular GP-assessment but a full understanding of the diagnostic value of the different features is still lacking. Recent studies emphasise the potential information embedded in the PPG waveform signal and it deserves further attention for its possible applications beyond pulse oximetry and heart-rate calculation. Therefore, this overview discusses different types of artifact added to PPG signal, characteristic features of PPG waveform, and existing indexes to evaluate for diagnoses. Keywords: Photoplethysmography, acceleration plethysmogram, second derivative plethysmogram, digital volume pulse, ageing, artery, autonomic function, blood pressure, cardiovascular, heart rate, pulse wave analysis, vascular disease
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Figures












![Fig. (13) Typical PPG waveforms show the parameters changes with age [62].](/paper-figures/8ee5a57901c347579a7a5160e4be1526/on-the-analysis-of-fingertip-photoplethysmogram-signals-figure-13.jpg)


![Fig. (16) APG waveforms and types of photoplethysmogram [73]. There are different types of APG waveforms. The first APG waveform A (far left) refers to good circulation, whereas the amplitude of b wave is lower than c wave. The last APG waveform G (far right) refers to distinctively bad circulation, whereas the amplitude of c wave is lower than b wave.](/paper-figures/54ec3ef6e18e4116ad4a30b26f4dd445/on-the-analysis-of-fingertip-photoplethysmogram-signals-figure-16.jpg)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The shape of a clean PPG signal is closely related to the blood pulse wave of the human body25”
From Data quality evaluation in wearable monitoring (2022) · cites this paper as [25]
In the citing paper
“In this case, the pulsatile component of the PPG can be of the order of 1 mV in amplitude [55] although lower amplitudes can be caused by technical factors, such as inappropriate gain control, or physiological factors, such as vasoconstriction [9].”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [9]
In the citing paper
“In particular, obesity can lead to changes in skin thickness, blood flow, and oxygen saturation. This affects the optical properties of skin in addition to the distance light has to travel to reach a target vessel or vessels [48,59,60].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [59]
In the citing paper
“While, to the authors’ knowledge, publications that experimentally and explicitly demonstrate the effect of obesity or BMI on the PPG waveform are limited, we will explore works which suggest that there would be a substantial effect [56,59,60,61,62,63,64,65,66,67,68,69,70].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [59]
In the citing paper
“The ratio b/a has been found to correlate positively to age, while c/a, d/a and e/a have all been correlated negatively to age [29,59].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [59]
In the citing paper
“| e/a | Decrease | Takazawa et al., 1998 Elgendi et al., 2012 | [29,59] |”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [59]
In the citing paper
“| d/a | Decrease | Takazawa et al., 1998 Elgendi et al., 2012 | [29,59] |”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [59]
In the citing paper
“| c/a | Decrease | Takazawa et al., 1998 Elgendi et al., 2012 | [29,59] |”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [59]
In the citing paper
“Furthermore, PPG can be used to index heart rate variability (HRV), blood pressure, oxygen saturation, and cardiac output24, but as of yet have not be widely rolled out in consumer-use devices and therefore data collection other than HR will not be discussed further.”
From Guidelines for wrist-worn consumer wearable assessment of heart rate in biobehavioral research (2020) · cites this paper as [24]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Assessment of fat-free mass using bioelectrical impedance measurements of the human body
Lukaski, H., Johnson, P., Bolonchuk, W., & Lykken, G. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/41.4.810 · Cited by 1,896
Investigation of Chronic Venous Insufficiency: A Consensus Statement
Nicolaides, A. N. (2000) · Circulation · doi:10.1161/01.cir.102.20.e126 · Cited by 945
Fifteen years experience with finger arterial pressure monitoring: assessment of the technology
Imholz, B. P. M. (1998) · Cardiovascular Research · doi:10.1016/s0008-6363(98)00067-4 · Cited by 841
Determination of age-related increases in large artery stiffness by digital pulse contour analysis
Millasseau, S., Kelly, R. P., Ritter, J., & Chowienczyk, P. (2002) · Clinical Science · doi:10.1042/cs1030371 · Cited by 624
Takazawa, K., Tanaka, N., Fujita, M., Matsuoka, O., Saiki, T., Aikawa, M., Tamura, S., & Ibukiyama, C. (1998) · Hypertension · doi:10.1161/01.hyp.32.2.365 · Cited by 589
Photoelectric measurement of blood pressure, volume and flow in the finger
Peňáz, J. (1973) · Medical Entomology and Zoology · Cited by 528
Mobile monitoring with wearable photoplethysmographic biosensors
Asada, H. H., Shaltis, P., Reisner, A., Rhee, S., & Hutchinson, R. C. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213624 · Cited by 466
Gil, E., Orini, M., Bailón, R., Vergara, J. M., Mainardi, L., & Laguna, P. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/9/015 · Cited by 461
THE BLOOD SUPPLY OF VARIOUS SKIN AREAS AS ESTIMATED BY THE PHOTOELECTRIC PLETHYSMOGRAPH
Hertzman, A. B. (1938) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1938.124.2.328 · Cited by 455
Research works printed but not linked: 3
- [59]Takazawa KTN Fujita M Matsuoka O Saiki T Aikawa M Tamura S Ibukiyama C Assessment of vasocative agents and vascular aging by the second derivative of photoplethysmogram waveform Hypertension 1998 32 365 70 9719069
- [80]Elgendi M Jonkman M De Boer F Fred A Filipe J Gamboa h Heart Rate Variability and Acceleration Plethysmogram measured at rest Biomedical Engineering Systems and Technologies: 2011 Springer 266 77
- [81]Tokutaka H MY Gonda E Yamamoto M Construction of a General Physical Condition Judgment System Using Acceleration Plethysmogram Pulse-Wave Analysis 2009 Berlin/Heidelberg Springer 5629 307 15
Cited by
Sorted by citations
Items 101–200 of 1,001
Pervasive blood pressure monitoring using Photoplethysmogram (PPG) sensor
Riaz, F., Azad, M. A., Arshad, J., Imran, M. A., Hassan, A., & Rehman, S. (2019) · Future Generation Computer Systems · doi:10.1016/j.future.2019.02.032 · Cited by 74
Smartphone Apps Using Photoplethysmography for Heart Rate Monitoring: Meta-Analysis
Ridder, B. D., Rompaey, B. V., Kampen, J. K., Haine, S. E. F., & Dilles, T. (2018) · JMIR Cardio · doi:10.2196/cardio.8802 · Cited by 73
Enabling the Unconstrained Epidermal Pulse Wave Monitoring via Finger‐Touching
Wang, X., Yang, J., Meng, K., He, Q., Zhang, G., Zhou, Z., Tan, X., Feng, Z., Sun, C., Yang, J., et al. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202102378 · Cited by 75
Detection of c, d, and e waves in the acceleration photoplethysmogram
Elgendi, M. (2014) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2014.08.001 · Cited by 73
Self-citationBiometric Authentication Using the PPG: A Long-Term Feasibility Study
Sancho, J., Alesanco, Á., & García, J. (2018) · Sensors · doi:10.3390/s18051525 · Cited by 72
Xu, Z., Liu, J., Chen, X., Wang, Y., & Zhao, Z. (2017) · Computers in Industry · doi:10.1016/j.compind.2017.04.003 · Cited by 71
Rajala, S., Lindholm, H., & Taipalus, T. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aac7ac · Cited by 70
Saffaryazdi, N., Wasim, S. T., Dileep, K., Nia, A. F., Nanayakkara, S., Broadbent, E., & Billinghurst, M. (2022) · Frontiers in Psychology · doi:10.3389/fpsyg.2022.864047 · Cited by 69
A Multimodal Data Fusion Technique for Heartbeat Detection in Wearable IoT Sensors
John, A., Redmond, S. J., Cardiff, B., & John, D. (2021) · IEEE Internet of Things Journal · doi:10.1109/jiot.2021.3093112 · Cited by 70
Emotion detection and recognition using HRV features derived from photoplethysmogram signals
Rakshit, R., Reddy, V. R., & Deshpande, P. (2016) · doi:10.1145/3009960.3009962 · Cited by 71
Natarajan, K., Block, R., Yavarimanesh, M., Chandrasekhar, A., Mestha, L. K., Inan, O. T., Hahn, J., & Mukkamala, R. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3087105 · Cited by 67
Ramesh, J., Solatidehkordi, Z., Aburukba, R., & Sagahyroon, A. A. (2021) · Sensors · doi:10.3390/s21217233 · Cited by 73
Multimodal Wrist Biosensor for Wearable Cuff-less Blood Pressure Monitoring System
Rachim, V. P., & Chung, W. (2019) · Scientific Reports · doi:10.1038/s41598-019-44348-3 · Cited by 67
Mazumder, O., Roy, D., Bhattacharya, S., Sinha, A., & Pal, A. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8856691 · Cited by 68
Arrhythmia detection and classification using ECG and PPG techniques: a review
Neha, N., Sardana, H. K., Kanwade, R., & Tewary, S. (2021) · Physical and Engineering Sciences in Medicine · doi:10.1007/s13246-021-01072-5 · Cited by 73
Simone, G., Tordera, D., Delvitto, E., Peeters, B., van Breemen, A. J. J. M., Meskers, S. C. J., Janssen, R. A. J., & Gelinck, G. H. (2020) · Advanced Optical Materials · doi:10.1002/adom.201901989 · Cited by 64
Nurul Qashri Mahardika, T., Fuadah, Y. N., Jeong, D. U., & Lim, K. M. (2023) · Diagnostics · doi:10.3390/diagnostics13152566 · Cited by 67
Measurement of heart rate using photoplethysmography
Saquib, N., Papon, T. I., Ahmad, I., & Rahman, A. (2015) · International Conference on Networking, Systems and Security (NSysS) · doi:10.1109/nsyss.2015.7043525 · Cited by 64
Identification of Atrial Fibrillation by Quantitative Analyses of Fingertip Photoplethysmogram
Tang, S.-C., Huang, P.-W., Hung, C.-S., Shan, S.-M., Lin, Y.-H., Shieh, J., Lai, D., Wu, A.-Y. (., & Jeng, J. (2017) · Scientific Reports · doi:10.1038/srep45644 · Cited by 64
Synthetic photoplethysmogram generation using two Gaussian functions
Tang, Q., Chen, Z., Ward, R., & Elgendi, M. (2020) · Scientific Reports · doi:10.1038/s41598-020-69076-x · Cited by 62
Self-citationDuan, K., Qian, Z., Atef, M., & Wang, G. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7592189 · Cited by 62
A healthy dose of chaos: Using fractal frameworks for engineering higher-fidelity biomedical systems
Korolj, A., Wu, H., & Radisic, M. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.119363 · Cited by 62
Yang, S.-M., Sohn, J., Lee, S., Lee, J., & Kim, H. C. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.3009658 · Cited by 61
Non-invasive cuff-less blood pressure estimation using a hybrid deep learning model
Yang, S., Zhang, Y., Cho, S., Correia, R. G., & Morgan, S. P. (2021) · Optical and Quantum Electronics · doi:10.1007/s11082-020-02667-0 · Cited by 61
Fahoum, A. S. A., Al-Haija, A. O. A., & Alshraideh, H. A. (2023) · Bioengineering · doi:10.3390/bioengineering10020249 · Cited by 59
Applications Based on Service-Oriented Architecture (SOA) in the Field of Home Healthcare
Ávila, K., Sanmartin-Mendoza, P., Jabba, D., & Jimeno, M. (2017) · Sensors · doi:10.3390/s17081703 · Cited by 59
New aging index using signal features of both photoplethysmograms and acceleration plethysmograms
Ahn, J. M. (2017) · Healthcare Informatics Research · doi:10.4258/hir.2017.23.1.53 · Cited by 58
Clinical Validation of Heart Rate Apps: Mixed-Methods Evaluation Study
Vandenberk, T., Stans, J., Mortelmans, C., Haelst, R. V., Schelvergem, G. V., Pelckmans, C., Smeets, C. J. P. P., Lanssens, D., Cannière, H. D., Storms, V., et al. (2017) · JMIR mhealth and uhealth · doi:10.2196/mhealth.7254 · Cited by 58
Estimation of Mental Distress from Photoplethysmography
Zangróniz, R., Martínez‐Rodrigo, A., López, M. T., Pastor, J. M., & Fernández‐Caballero, A. (2018) · Applied Sciences · doi:10.3390/app8010069 · Cited by 59
Vahidi, M., Rizkalla, A. S., & Mequanint, K. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202401218 · Cited by 58
A Pulse Rate Estimation Algorithm Using PPG and Smartphone Camera
Siddiqui, S. A., Zhang, Y., Feng, Z., & Kos, A. (2016) · Journal of Medical Systems · doi:10.1007/s10916-016-0485-6 · Cited by 57
Seeing Red: PPG Biometrics Using Smartphone Cameras
Lovisotto, G., Turner, H., Eberz, S., & Martinović, I. (2020) · IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw50498.2020.00417 · Cited by 57
Lin, W.-H., Chen, F., Geng, Y., Ji, N., Fang, P., & Li, G. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.102198 · Cited by 59
Tai, Y., & Yang, Z. (2015) · Journal of Materials Chemistry B · doi:10.1039/c5tb00653h · Cited by 57
Biometric authentication using photoplethysmography signals
Sarkar, A., Abbott, A. L., & Doerzaph, Z. R. (2016) · IEEE International Conference on Biometrics: Theory, Applications and Systems (BTAS) · doi:10.1109/btas.2016.7791193 · Cited by 55
Cuffless and Continuous Blood Pressure Estimation From PPG Signals Using Recurrent Neural Networks
El-Hajj, C., & Kyriacou, P. A. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9175699 · Cited by 54
Motion robust PPG-imaging through color channel mapping
Moço, A., Stuijk, S., & de Haan, G. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.001737 · Cited by 53
Regulation of retinal oxygen metabolism in humans during graded hypoxia
Palkovits, S., Told, R., Schmidl, D., Boltz, A., Napora, K. J., Lasta, M., Kaya, S., Werkmeister, R. M., Popa‐Cherecheanu, A., Garhöfer, G., et al. (2014) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00479.2014 · Cited by 53
Peak Detection and HRV Feature Evaluation on ECG and PPG Signals
Esgalhado, F., Batista, A. G., Vassilenko, V., Russo, S., & Ortigueira, M. D. (2022) · Symmetry · doi:10.3390/sym14061139 · Cited by 57
Zanelli, S., Ammi, M., Hallab, M., & El‐Yacoubi, M. A. (2022) · Sensors · doi:10.3390/s22134890 · Cited by 57
Review of near-infrared methods for wound assessment
Sowa, M. G., Kuo, W., Ko, A. C. ‐., & Armstrong, D. G. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091304 · Cited by 52
Bidirectional Recurrent Auto-Encoder for Photoplethysmogram Denoising
Lee, J., Sun, S., Yang, S.-M., Sohn, J., Park, J., Lee, S., & Kim, H. C. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2018.2885139 · Cited by 54
Hasan, M. K., Aziz, M. H., Zarif, M. I. I., Hasan, M., Hashem, M. M. A., Guha, S., Love, R. R., & Ahamed, S. I. (2020) · JMIR mhealth and uhealth · doi:10.2196/16806 · Cited by 52
Moscato, S., Giudice, S. L., Massaro, G., & Chiari, L. (2022) · Sensors · doi:10.3390/s22155831 · Cited by 51
Arterial blood pressure feature estimation using photoplethysmography
zadi, A. S., Alex, R. M., Zhang, R., Watenpaugh, D. E., & Behbehani, K. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.09.013 · Cited by 51
Vascular Pressure–Flow Measurement Using CB-PDMS Flexible Strain Sensor
Chong, H., Lou, J., Bogie, K. M., Zorman, C. A., & Majerus, S. J. A. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2946519 · Cited by 51
Mental Stress Assessment Using PPG Signal a Deep Neural Network Approach
Kalra, P., & Sharma, V. K. (2020) · IETE Journal of Research · doi:10.1080/03772063.2020.1844068 · Cited by 53
Experimental system for measuring the full scattering profile of circular phantoms
Feder, I., Duadi, H., & Fixler, D. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.002877 · Cited by 50
SVR ensemble-based continuous blood pressure prediction using multi-channel photoplethysmogram
Fong, M. W. K., Ng, E. Y. K., Jian, K. E. Z., & Hong, T. J. (2019) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2019.103392 · Cited by 50
Lin, W.-H., Li, X., Li, Y., Li, G., & Chen, F. (2020) · Physiological Measurement · doi:10.1088/1361-6579/ab7d78 · Cited by 50
Hickey, M., Phillips, J. P., & Kyriacou, P. A. (2016) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-015-9761-0 · Cited by 49
Yao, P., Xue, N., Yin, S., You, C., Guo, Y., Shi, Y., Liu, T., Yao, L., Zhou, J., Sun, J., et al. (2022) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2022.3167059 · Cited by 49
Acoustic Sensing as a Novel Wearable Approach for Cardiac Monitoring at the Wrist
Sharma, P., Imtiaz, S. A., & Rodriguez–Villegas, E. (2019) · Scientific Reports · doi:10.1038/s41598-019-55599-5 · Cited by 52
The Application of Deep Learning Algorithms for PPG Signal Processing and Classification
Esgalhado, F., Fernandes, B., Vassilenko, V., Batista, A. G., & Russo, S. (2021) · Computers · doi:10.3390/computers10120158 · Cited by 49
Detection of atrial fibrillation using an earlobe photoplethysmographic sensor
Conroy, T. B., Guzman, J. H., HALL, B. W., Tsouri, G. R., & Couderc, J. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa8830 · Cited by 48
Evaluation of the Possible Use of PPG Waveform Features Measured at Low Sampling Rate
Fujita, D., & Suzuki, A. (2019) · IEEE Access · doi:10.1109/access.2019.2914498 · Cited by 48
Ali, N. F., & Atef, M. (2023) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2023.104782 · Cited by 47
The Impact of Heart Rate Variability Monitoring on Preventing Severe Cardiovascular Events
Turcu, A.-M., Ilie, A. C., Ștefăniu, R., Țăranu, S. M., Sandu, I. A., Alexa‐Stratulat, T., Pîslaru, A. I., & Alexa, I. D. (2023) · Diagnostics · doi:10.3390/diagnostics13142382 · Cited by 46
High‐Performing Acid‐Free PEDOT:PSS‐Based Organic Photodiodes for Cardiovascular Disease Diagnosis
Zhao, Y., Kim, B. G., Jang, W., Park, J. H., & Wang, D. H. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202309271 · Cited by 46
PPG-Based Systolic Blood Pressure Estimation Method Using PLS and Level-Crossing Feature
Fujita, D., Suzuki, A., & Ryu, K. (2019) · Applied Sciences · doi:10.3390/app9020304 · Cited by 46
A Single LED Photoplethysmography-Based Noninvasive Glucose Monitoring Prototype System
Hina, A., Nadeem, H., & Saadeh, W. (2019) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2019.8702747 · Cited by 46
Askarian, B., Jung, K., & Chong, J. W. (2019) · Sensors · doi:10.3390/s19132846 · Cited by 45
Loizaga, E., Eyam, A. T., Bastida, L., & Lastra, J. L. M. (2023) · IEEE Access · doi:10.1109/access.2023.3280071 · Cited by 51
Endothelial Dysfunction and Coronary Artery Disease
Veerasamy, M., Bagnall, A. J., Neely, D., Allen, J., Sinclair, H., & Kunadian, V. (2014) · Cardiology in Review · doi:10.1097/crd.0000000000000047 · Cited by 45
Attarpour, A., Mahnam, A., Aminitabar, A., & Samani, H. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.12.006 · Cited by 45
Research on digital technology use in cardiology: bibliometric analysis
Yeung, A. W. K., Kulnik, S. T., Parvanov, E. D., Fassl, A., Eibensteiner, F., Völkl-Kernstock, S., Kletecka-Pulker, M., Crutzen, R., Gutenberg, J., Höppchen, I., et al. (2022) · Journal of Medical Internet Research · doi:10.2196/36086 · Cited by 44
PhotoECG: Photoplethysmographyto estimate ECG parameters
Banerjee, R., Sinha, A., Choudhury, A. D., & Visvanathan, A. (2014) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2014.6854434 · Cited by 44
Depressed Mood Prediction of Elderly People with a Wearable Band
Choi, J., Lee, S., Kim, S., Kim, D., & Kim, H. (2022) · Sensors · doi:10.3390/s22114174 · Cited by 43
The effect of vascular changes on the photoplethysmographic signal at different hand elevations
Hickey, M., Phillips, J. P., & Kyriacou, P. A. (2015) · Physiological Measurement · doi:10.1088/0967-3334/36/3/425 · Cited by 43
Cheatham, S. W., Kolber, M. J., & Ernst, M. P. (2014) · Journal of Sport Rehabilitation · doi:10.1123/jsr.2013-0145 · Cited by 43
Deep recurrent neural network-based autoencoder for photoplethysmogram artifacts filtering
Azar, J., Makhoul, A., Couturier, R., & Demerjian, J. (2021) · Computers & Electrical Engineering · doi:10.1016/j.compeleceng.2021.107065 · Cited by 46
Standard Terminologies for Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312803217184 · Cited by 43
Self-citationWearable photoplethysmography devices
Marozas, V., & Charlton, P. H. (2021) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.4601547 · Cited by 43
Pant, S., Umesh, S., & Asokan, S. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2973342 · Cited by 42
Mazumder, O., Banerjee, R., Roy, D., Bhattacharya, S., Ghose, A., & Sinha, A. (2022) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2022.3147383 · Cited by 42
Estimation of blood pressure levels from reflective Photoplethysmograph using smart phones
Visvanathan, A., Sinha, A., & Pal, A. (2013) · IEEE International Conference on Bioinformatics and Bioengineering (BIBE) · doi:10.1109/bibe.2013.6701568 · Cited by 45
Progress in Data Acquisition of Wearable Sensors
Liu, Z., Kong, J., Qu, M., Zhao, G., & Zhang, C. (2022) · Biosensors · doi:10.3390/bios12100889 · Cited by 41
Blood Pressure Measurement: From Cuff-Based to Contactless Monitoring
Man, P.-K., Cheung, K.-L., Sangsiri, N., Shek, W., Wong, K. L., Chin, J. W., Chan, T. T., & So, R. H. Y. (2022) · Healthcare · doi:10.3390/healthcare10102113 · Cited by 40
Spatiotemporal hemodynamic monitoring via configurable skin-like microfiber Bragg grating group
Zhu, H., Luo, J., Dai, Q., Zhu, S., Yang, H., Zhou, K., Zhan, L., Xu, B., Chen, Y., Lu, Y., et al. (2023) · Opto-Electronic Advances · doi:10.29026/oea.2023.230018 · Cited by 40
Comparison of Green, Blue and Infrared Light in Wrist and Forehead Photoplethysmography
Vizbara, V. (2013) · Cited by 40
Meng, K., Wu, Y., He, Q., Zhou, Z., Wang, X., Zhang, G., Fan, W., Liu, J., & Yang, J. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b12747 · Cited by 40
Puranik, S., & Morales, A. W. (2019) · IEEE Transactions on Consumer Electronics · doi:10.1109/tce.2019.2961263 · Cited by 40
Banik, P. P., Hossain, S., Kwon, T.-H., Kim, H., & Kim, K. (2020) · Electronics · doi:10.3390/electronics9111905 · Cited by 40
Deep learning via ECG and PPG signals for prediction of depth of anesthesia
Chowdhury, M. R., Madanu, R., Abbod, M., Fan, S., & Shieh, J.-S. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102663 · Cited by 40
Robust Continuous Authentication Using Cardiac Biometrics From Wrist-Worn Wearables
Zhao, T., Wang, Y., Liu, J., Cheng, J., Chen, Y. J., & Yu, J. (2021) · IEEE Internet of Things Journal · doi:10.1109/jiot.2021.3128290 · Cited by 40
Nishan, A., Raju, S. M. T. U., Hossain, M. I., Dipto, S. A., Uddin, S. M. T., Sijan, A., Chowdhury, M. A. S., Ahmad, A., & Khan, M. M. H. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e27779 · Cited by 39
A Case Study of Trust on Autonomous Driving
Sheng, S., Pakdamanian, E., Han, K., Kim, B., Tiwari, P., Kim, I., & Feng, L. (2019) · IEEE International Conference on Intelligent Transportation Systems (ITSC) · doi:10.1109/itsc.2019.8917251 · Cited by 42
A Paper-Based Flexible Tactile Sensor Array for Low-Cost Wearable Human Health Monitoring
Luo, W., Sharma, V., & Young, D. J. (2020) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2020.3011498 · Cited by 39
Haque, M. R., Raju, S. M. T. U., Golap, M. A.-U., & Hashem, M. M. A. (2021) · IEEE Access · doi:10.1109/access.2021.3054236 · Cited by 39
Geng, F., Bai, Z., Zhang, H., Yao, Y., Liu, C., Wang, P., Chen, X., Du, L., Li, X., Han, B., et al. (2023) · Measurement · doi:10.1016/j.measurement.2023.113151 · Cited by 38
PPG/ECG Multisite Combo System Based on SiPM Technology
Vinciguerra, V., Ambra, E., Maddiona, L., Romeo, M. F., Mazzillo, M. C., Rundo, F., Fallica, G., Pompeo, F., Chiarelli, A. M., Zappasodi, F., et al. (2019) · Lecture notes in electrical engineering · doi:10.1007/978-3-030-04324-7_44 · Cited by 38
Mamun, M. M. R. K., & Sherif, A. (2022) · Bioengineering · doi:10.3390/bioengineering10010027 · Cited by 41
Jang, H.-H., Park, J., & Choi, B. (2018) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2018.12.015 · Cited by 37
Baldoumas, G., Peschos, D., Tatsis, G., Chronopoulos, S. K., Christofilakis, V., Kostarakis, P., Varotsos, P. A., Sarlis, N. V., Skordas, E. S., Bechlioulis, A., et al. (2019) · Electronics · doi:10.3390/electronics8111288 · Cited by 37
Aygun, A., Ghasemzadeh, H. G., & Jafari, R. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2962627 · Cited by 42
Al-Halawani, R., Qassem, M., & Kyriacou, P. A. (2024) · Scientific Reports · doi:10.1038/s41598-024-58435-7 · Cited by 36
Baron, R., & Haick, H. (2024) · ACS Sensors · doi:10.1021/acssensors.4c00636 · Cited by 37
Biophysical markers of the peripheral vasoconstriction response to pain in sickle cell disease
Chalacheva, P., Khaleel, M., Sunwoo, J., Shah, P., Detterich, J. A., Kato, R. M., Thuptimdang, W., Meiselman, H. J., Sposto, R., Tsao, J., et al. (2017) · PLoS ONE · doi:10.1371/journal.pone.0178353 · Cited by 36
Aslan, S., Hocke, L. M., Schwarz, N. F., & Frederick, B. B. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.05.049 · Cited by 36
Hettiarachchi, C., & Chitraranjan, C. D. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-21642-9_41 · Cited by 36
Metadata
- Authors
- Elgendi, M.
- Affiliations
- Charles Darwin University (AU)
- Corresponding author
- Elgendi, Mohamed
- ORCID
- Elgendi, Mohamed
- Venue
- Current Cardiology Reviews
- Publisher
- Bentham Science Publishers Ltd.
- Published
- 2012-06-01
- Volume
- 8
- Issue
- 1
- Pages
- 14-25
- ISSN
- 1573-403X (ISSN-L)
- PMC
- PMC3394104
- OpenAlex
- W1981918735
- Cited by
- 1,206
- References
- 88
- Citations by year
- 2026: 120 · 2025: 106 · 2024: 116 · 2023: 109 · 2022: 130 · 2021: 114 · 2020: 118 · 2019: 118 · 2018: 86 · 2017: 65 · 2016: 46 · 2015: 42 · 2014: 24 · 2013: 11 · 2012: 1
- FWCI
- 2.17
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Current Cardiology Reviews (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DR-NTU (Nanyang Technological University) (submittedVersion)
- Funders
- Univerzita Karlova v Praze
- Australian Government
- Charles Darwin University
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- photoplethysmography, digital volume pulse, aging, autonomic function, blood pressure, heart rate, pulse wave analysis, cardiovascular disease, vascular disease, atherosclerosis screening
- MeSH terms
- Fingers, Hemodynamics, Humans, Skin, Artifacts, Photoplethysmography, Pulse Wave Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.