On the Analysis of Fingertip Photoplethysmogram Signals
Open accessAbstract
Photoplethysmography (PPG) is used to estimate the skin blood flow using infrared light. Researchers from different domains of science have become increasingly interested in PPG because of its advantages as non-invasive, inexpensive, and convenient diagnostic tool. Traditionally, it measures the oxygen saturation, blood pressure, cardiac output, and for assessing autonomic functions. Moreover, PPG is a promising technique for early screening of various atherosclerotic pathologies and could be helpful for regular GP-assessment but a full understanding of the diagnostic value of the different features is still lacking. Recent studies emphasise the potential information embedded in the PPG waveform signal and it deserves further attention for its possible applications beyond pulse oximetry and heart-rate calculation. Therefore, this overview discusses different types of artifact added to PPG signal, characteristic features of PPG waveform, and existing indexes to evaluate for diagnoses. Keywords: Photoplethysmography, acceleration plethysmogram, second derivative plethysmogram, digital volume pulse, ageing, artery, autonomic function, blood pressure, cardiovascular, heart rate, pulse wave analysis, vascular disease
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Figures












![Fig. (13) Typical PPG waveforms show the parameters changes with age [62].](/paper-figures/8ee5a57901c347579a7a5160e4be1526/on-the-analysis-of-fingertip-photoplethysmogram-signals-figure-13.jpg)


![Fig. (16) APG waveforms and types of photoplethysmogram [73]. There are different types of APG waveforms. The first APG waveform A (far left) refers to good circulation, whereas the amplitude of b wave is lower than c wave. The last APG waveform G (far right) refers to distinctively bad circulation, whereas the amplitude of c wave is lower than b wave.](/paper-figures/54ec3ef6e18e4116ad4a30b26f4dd445/on-the-analysis-of-fingertip-photoplethysmogram-signals-figure-16.jpg)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“| c/a | Decrease | Takazawa et al., 1998 Elgendi et al., 2012 | [29,59] |”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [59]
In the citing paper
“The shape of a clean PPG signal is closely related to the blood pulse wave of the human body25”
From Data quality evaluation in wearable monitoring (2022) · cites this paper as [25]
In the citing paper
“In this case, the pulsatile component of the PPG can be of the order of 1 mV in amplitude [55] although lower amplitudes can be caused by technical factors, such as inappropriate gain control, or physiological factors, such as vasoconstriction [9].”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [9]
In the citing paper
“In particular, obesity can lead to changes in skin thickness, blood flow, and oxygen saturation. This affects the optical properties of skin in addition to the distance light has to travel to reach a target vessel or vessels [48,59,60].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [59]
In the citing paper
“While, to the authors’ knowledge, publications that experimentally and explicitly demonstrate the effect of obesity or BMI on the PPG waveform are limited, we will explore works which suggest that there would be a substantial effect [56,59,60,61,62,63,64,65,66,67,68,69,70].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [59]
In the citing paper
“The ratio b/a has been found to correlate positively to age, while c/a, d/a and e/a have all been correlated negatively to age [29,59].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [59]
In the citing paper
“| e/a | Decrease | Takazawa et al., 1998 Elgendi et al., 2012 | [29,59] |”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [59]
In the citing paper
“| d/a | Decrease | Takazawa et al., 1998 Elgendi et al., 2012 | [29,59] |”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [59]
In the citing paper
“Furthermore, PPG can be used to index heart rate variability (HRV), blood pressure, oxygen saturation, and cardiac output24, but as of yet have not be widely rolled out in consumer-use devices and therefore data collection other than HR will not be discussed further.”
From Guidelines for wrist-worn consumer wearable assessment of heart rate in biobehavioral research (2020) · cites this paper as [24]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Assessment of fat-free mass using bioelectrical impedance measurements of the human body
Lukaski, H., Johnson, P., Bolonchuk, W., & Lykken, G. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/41.4.810 · Cited by 1,896
Investigation of Chronic Venous Insufficiency: A Consensus Statement
Nicolaides, A. N. (2000) · Circulation · doi:10.1161/01.cir.102.20.e126 · Cited by 945
Fifteen years experience with finger arterial pressure monitoring: assessment of the technology
Imholz, B. P. M. (1998) · Cardiovascular Research · doi:10.1016/s0008-6363(98)00067-4 · Cited by 841
Determination of age-related increases in large artery stiffness by digital pulse contour analysis
Millasseau, S., Kelly, R. P., Ritter, J., & Chowienczyk, P. (2002) · Clinical Science · doi:10.1042/cs1030371 · Cited by 624
Takazawa, K., Tanaka, N., Fujita, M., Matsuoka, O., Saiki, T., Aikawa, M., Tamura, S., & Ibukiyama, C. (1998) · Hypertension · doi:10.1161/01.hyp.32.2.365 · Cited by 589
Photoelectric measurement of blood pressure, volume and flow in the finger
Peňáz, J. (1973) · Medical Entomology and Zoology · Cited by 528
Mobile monitoring with wearable photoplethysmographic biosensors
Asada, H. H., Shaltis, P., Reisner, A., Rhee, S., & Hutchinson, R. C. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213624 · Cited by 466
Gil, E., Orini, M., Bailón, R., Vergara, J. M., Mainardi, L., & Laguna, P. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/9/015 · Cited by 461
THE BLOOD SUPPLY OF VARIOUS SKIN AREAS AS ESTIMATED BY THE PHOTOELECTRIC PLETHYSMOGRAPH
Hertzman, A. B. (1938) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1938.124.2.328 · Cited by 460
Research works printed but not linked: 3
- [59]Takazawa KTN Fujita M Matsuoka O Saiki T Aikawa M Tamura S Ibukiyama C Assessment of vasocative agents and vascular aging by the second derivative of photoplethysmogram waveform Hypertension 1998 32 365 70 9719069
- [80]Elgendi M Jonkman M De Boer F Fred A Filipe J Gamboa h Heart Rate Variability and Acceleration Plethysmogram measured at rest Biomedical Engineering Systems and Technologies: 2011 Springer 266 77
- [81]Tokutaka H MY Gonda E Yamamoto M Construction of a General Physical Condition Judgment System Using Acceleration Plethysmogram Pulse-Wave Analysis 2009 Berlin/Heidelberg Springer 5629 307 15
Cited by
Sorted by citations
Items 501–600 of 1,001
Real‐time photoplethysmographic heart rate measurement using deep neural network filters
Kim, J. W., Park, S., & Choi, S. W. (2021) · ETRI Journal · doi:10.4218/etrij.2020-0394 · Cited by 9
Yavarimanesh, M., Cheng, H., Chen, C., Sung, S., Mahajan, A., Chaer, R. A., Shroff, S. G., Hahn, J., & Mukkamala, R. (2022) · npj Digital Medicine · doi:10.1038/s41746-022-00717-3 · Cited by 9
van Putten, L. D., & Bamford, K. E. (2023) · IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw59228.2023.00634 · Cited by 9
Sanuki, H., Fukui, R., Inajima, T., & Warisawa, S. (2017) · International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC) · doi:10.5220/0006112500420048 · Cited by 9
Mohanalakshmi, S., Mohanalakshmi, S., Sivasubramanian, A., & Swarnalatha, A. (2017) · Indian Journal of Science and Technology · doi:10.17485/ijst/2017/v10i12/104111 · Cited by 9
Biometric Authentication via Finger Photoplethysmogram
Zhang, X., Qin, Z., & Lyu, Y. (2018) · doi:10.1145/3297156.3297174 · Cited by 9
Machine learning for the early prediction of head-up tilt testing outcome
He, Z., Du, L., Du, S., Wu, B., Fan, Z., Xin, B., Chen, X., Fang, Z., & Liu, J. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102904 · Cited by 9
Security Information System, Based on Fingerprint Biometrics
(2019) · Acta Polytechnica Hungarica · doi:10.12700/aph.16.5.2019.5.6 · Cited by 9
Burton, T., Fathieh, F., Nemati, N., Gillins, H. R., Shadforth, I., Ramchandani, S., & Bridges, C. R. (2024) · Diagnostics · doi:10.3390/diagnostics14070719 · Cited by 9
Liu, C., Zheng, D., & Murray, A. (2015) · Medicine · doi:10.1097/md.0000000000001831 · Cited by 9
The Role of the Autonomic Nervous System in Cardiovascular Toxicity
Carll, A. P., Farraj, A. K., & Roberts, A. M. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-801238-3.64259-9 · Cited by 9
Development of hybrid artificial intelligence based automatic sleep/awake detection
Bozkurt, M. R., Uçar, M. K., Bozkurt, F., & Bílgín, C. (2019) · IET Science Measurement & Technology · doi:10.1049/iet-smt.2019.0034 · Cited by 9
Comparison of Bi-Wavelength and Tri-Wavelength Photoplethysmography Sensors Placed on the Forehead
Longmore, S. K., Jalaludin, B. B., Breen, P. P., & Gargiulo, G. D. (2019) · International Conference on Electrical Engineering Research & Practice (ICEERP) · doi:10.1109/iceerp49088.2019.8956987 · Cited by 9
Haghi, M., Danyali, S., Thurow, K., Warnecke, J. M., Wang, J., & Deserno, T. M. (2020) · Applied Sciences · doi:10.3390/app10165470 · Cited by 9
Photoplethysmography for the assessment of peripheral vascular disease
Allen, J. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-823374-0.00005-0 · Cited by 9
Photoplethysmography Detection of Overreaching
Bourdillon, N., Nilchian, M., & Millet, G. P. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001836 · Cited by 9
Mathieu, A. J. W., Serna‐Pascual, M., Charlton, P. H., Volovaya, M., Venton, J., Aston, P. J., Nandi, M., & Alastruey, J. (2024) · JRSM Cardiovascular Disease · doi:10.1177/20480040231225384 · Cited by 13
Arefin, K. Z., Alam, K. S., Mamun, S. M., Sabith, N. U. S., Rabbani, M., Sridevi, P., & Ahamed, S. I. (2025) · Smart Health · doi:10.1016/j.smhl.2025.100542 · Cited by 8
Context matters: Optimal green wall geometry for window views vary with sound conditions
Li, W., Liu, Y., & Li, Y. (2025) · Journal of Environmental Psychology · doi:10.1016/j.jenvp.2025.102834 · Cited by 8
Flexible wearable sensors for sports training: recent advances and future perspectives
Jin, H., Wang, W., Chen, S., Zhang, G., Tong, Y., Lu, D., Li, J., He, L. M., & Tang, X. (2026) · Materials & Design · doi:10.1016/j.matdes.2026.115994 · Cited by 8
Advances and Challenges in Wearable Sensors for Health Monitoring
Brazaca, L. C., Lozano, A. M., Mayol, B., Scheidt, D. T., Fazio, D. D., Kim, E., Maroli, G., Rosati, G., Ates, H. C., Wang, H., et al. (2026) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6c04520 · Cited by 9
Coronary artery disease and its impact on the pulsatile brain: A functional NIRS study
Mohammadi, H., Vincent, T. L., Peng, K., Nigam, A., Gayda, M., Fraser, S., Joanette, Y., Lesage, F., & Bherer, L. (2021) · Human Brain Mapping · doi:10.1002/hbm.25463 · Cited by 8
GSM and Arduino Based Vital Sign Monitoring System
Austin, R., Lobo, F., & Rajaguru, S. (2021) · The Open Biomedical Engineering Journal · doi:10.2174/1874120702115010078 · Cited by 8
Photoplethysmography wave morphology in patients with atrial fibrillation
Basza, M., Waląg, D., Kowalczyk, W., Bożym, A., Ciurla, M., Krzyżanowska, M., Maciejewski, C., Bojanowicz, W., Soliński, M., & Kołtowski, Ł. (2023) · Physiological Measurement · doi:10.1088/1361-6579/acc725 · Cited by 8
Enhanced SpO2 estimation using explainable machine learning and neck photoplethysmography
Zhong, Y., Jatav, A., Afrin, K., Shivaram, T., & Bukkapatnam, S. (2023) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2023.102685 · Cited by 8
Cuffless Blood Pressure Estimation Model Using Clustering Techniques
Baek, J., Lee, B., Rachim, V. P., Jang, J., Kim, S., Kim, H. C., & Park, S. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3327683 · Cited by 8
UbiHeart: A novel approach for non-invasive blood pressure monitoring through real-time facial video
Alam, K. S., Mamun, S. M., Rabbani, M., Sridevi, P., & Ahamed, S. I. (2024) · Smart Health · doi:10.1016/j.smhl.2024.100473 · Cited by 8
Evaluating Vascular Depth-Dependent Changes in Multi-Wavelength PPG Signals Due to Contact Force
Cause, J. L., Morillo, Á. S., da Silva, B., Naranjo, J. C. G., & Stiens, J. H. (2024) · Sensors · doi:10.3390/s24092692 · Cited by 9
Fingertip Video Dataset for Non-Invasive Diagnosis of Anemia Using ResNet-18 Classifier
Sabir, H., Khan, K. U., Ishaq, O., Alazeb, A., Aljuaid, H., Algarni, A. M., & Park, J. (2024) · IEEE Access · doi:10.1109/access.2024.3398353 · Cited by 8
Hellqvist, H., Rietz, H., Grote, L., Hedner, J. A., Sommermeyer, D., Kahan, T., & Spaak, J. (2025) · Heart and Vessels · doi:10.1007/s00380-025-02537-3 · Cited by 10
Development of a FPGA-based contactless pulse rate detection system
Lin, Y.-C., Lin, G., & Lin, Y. (2016) · International Conference on Intelligent Green Building and Smart Grid · doi:10.1109/igbsg.2016.7539420 · Cited by 8
Recognizing cardiovascular risk from photoplethysmogram signals using ELM
Shobitha, S., Sandhya, R., Niranjana Krupa, B., & Ali, M. A. M. (2016) · International Conference on Cognitive Computing and Information Processing · doi:10.1109/ccip.2016.7802864 · Cited by 8
Compressive Sensing of Cuff-less Biosensor for Energy-Efficient Blood Pressure Monitoring
Rachim, V. P., & Chung, W. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8857840 · Cited by 8
Alqudah, A. M., Qananwah, Q. M., Dagamseh, A., Qazan, S., Al-Badarneh, A., & Alzyout, A. (2020) · Medical Hypotheses · doi:10.1016/j.mehy.2020.109870 · Cited by 8
Transcending Conventional Biometry Frontiers: Diffusive Dynamics PPG Biometry
de Pedro-Carracedo, J., Fuentes-Jiménez, D., Ugena, A. M., & Gonzalez-Marcos, A. P. (2021) · Sensors · doi:10.3390/s21165661 · Cited by 8
A Synthetic Data Generation Model for Diabetic Foot Treatment
Hyun, J., Lee, S. H., Son, H. M., Park, J., & Chung, T. (2020) · Communications in computer and information science · doi:10.1007/978-981-33-4370-2_18 · Cited by 8
Seo, J.-W., Choi, J.-M., Lee, K. H., & Kim, J. U. (2021) · Sensors · doi:10.3390/s21237782 · Cited by 8
COVID-19 Detection Using Photoplethysmography and Neural Networks
Lombardi, S., Francia, P., Deodati, R., Calamai, I., Luchini, M., Spina, R., & Bocchi, L. (2023) · Sensors · doi:10.3390/s23052561 · Cited by 8
Pulse rate variability: An alternative to heart rate variability in adults with spinal cord injury
Schoffl, J., Pozzato, I., Rodrigues, D., Arora, M., & Craig, A. R. (2023) · Psychophysiology · doi:10.1111/psyp.14356 · Cited by 8
von Wowern, E., Saldeen, P., & Olofsson, P. (2018) · Hypertension in Pregnancy · doi:10.1080/10641955.2018.1516225 · Cited by 8
Optimizing performance of reflectance-based organic Photoplethysmogram (PPG) sensor
Bilgaiyan, A., Sugawara, R., Elsamnah, F., Shim, C.-H., Misran, M. A. B., & Hattori, R. (2018) · Organic and Hybrid Sensors and Bioelectronics · doi:10.1117/12.2321060 · Cited by 8
Exploring the Usage of Time-of-Flight Cameras for Contact and Remote Photoplethysmography
Nahler, C., Feldhofer, B., Rüther, M., Holweg, G., & Druml, N. (2018) · Euromicro Conference on Digital System Design (DSD) · doi:10.1109/dsd.2018.00079 · Cited by 8
Sensor factors influencing photoplethysmography
Timimi, A. Y. K., & Ali, M. A. M. (2014) · IEEE Asia Pacific Conference on Circuits and Systems (APCCAS) · doi:10.1109/apccas.2014.7032808 · Cited by 8
Use of photoplethysmography to predict mortality in intensive care units
Kock, K. D. S., & Marques, J. L. B. (2018) · Vascular Health and Risk Management · doi:10.2147/vhrm.s172643 · Cited by 8
Bhattacharya, S., Mazumder, O., Roy, D., Sinha, A., & Ghose, A. (2020) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp40776.2020.9054570 · Cited by 8
Harmonic components of photoplethysmography and pathological patterns: A cross-sectional study
Park, Y.-J., Lee, J.-M., & Choi, K.-H. (2023) · Medicine · doi:10.1097/md.0000000000034200 · Cited by 7
Taylor-Fourier Analysis of Photoplethysmography Signals for Heart Rate Measurement
Rahbar, S., Ferrero, R., Pegoraro, P. A., & Toscani, S. (2024) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc60896.2024.10560902 · Cited by 7
Gruwez, H., Herendael, H. V., Maris, S., Dhont, S., Meekers, E. M., Bruckers, L. M., Wouters, F., Rivero‐Ayerza, M., Nuyens, D., Vandervoort, P. M., et al. (2024) · Heart Rhythm · doi:10.1016/j.hrthm.2024.11.026 · Cited by 7
Du, J., Xi, Y., Weng, J., Han, B., & Ding, H. (2026) · Reliability Engineering & System Safety · doi:10.1016/j.ress.2026.112280 · Cited by 7
A filamentary soft robotic probe for multimodal in utero monitoring of fetal health
Bai, H., Zhou, J., Wu, M., Papastefan, S. T., Li, X., Zhang, H., Zhao, K., Zhang, Z., Ouyang, W., Redden, C. R., et al. (2026) · Nature Biomedical Engineering · doi:10.1038/s41551-025-01605-3 · Cited by 7
Pernice, R., Parisi, A., Guarino, S., Fallica, G., Vinciguerra, V., Ferla, G., Faes, L., & Busacca, A. (2020) · IEEE Mediterranean Electrotechnical Conference (MELECON) · doi:10.1109/melecon48756.2020.9140716 · Cited by 7
A novel method for vascular age estimation via pressure pulse wave of radial artery
Tang, Q., Tao, C., Pan, Z., Wang, G., Liu, K., Pan, Z., Liu, G., Su, B., & Liu, N. (2022) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2022.103904 · Cited by 7
Cultivating concern for others: Meditation training and motivated engagement with human suffering.
King, B. G., Zanesco, A. P., Skwara, A. C., & Saron, C. D. (2023) · Journal of Experimental Psychology General · doi:10.1037/xge0001431 · Cited by 8
Nocturnal Blood Pressure Estimation from Sleep Plethysmography Using Machine Learning
Yılmaz, G., Lyu, X., Ong, J. L., Ling, L. H., Penzel, T., Yeo, B. T. T., & Chee, M. W. L. (2023) · Sensors · doi:10.3390/s23187931 · Cited by 7
Xing, X., Dong, W., Xiao, R., Song, M., & Jiang, C. (2023) · Entropy · doi:10.3390/e25121582 · Cited by 7
Dynamic Peripheral Hemoperfusion Distribution Monitoring Based on Janus Flexible Sensor System
Huang, C., He, O., Lao, Z., Liu, H., Leng, Y., Xu, X., Tian, S. T., Wang, Y., Wu, G., Li, R., et al. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3381637 · Cited by 7
Marchi, B. D., Agovi, E., & Aliverti, A. (2024) · Information Systems Frontiers · doi:10.1007/s10796-024-10550-6 · Cited by 7
Sattar, R. R. M., Chellappan, K., Aminuddin, A., Omar, N., Zakaria, Z., Ali, M. A. M., & Nordin, N. A. M. M. (2014) · IEEE-EMBS Conference on Biomedical Engineering and Sciences · doi:10.1109/iecbes.2014.7047574 · Cited by 7
Noninvasive Blood Glucose Prediction from Photoplethysmogram Using Relevance Vector Machine
Shobitha, S., Amita, P. M., Niranjana Krupa, B., & Ali, M. A. M. (2018) · IEEE International Conference for Convergence in Technology (I2CT) · doi:10.1109/i2ct.2018.8529481 · Cited by 7
PPG motion artifact reduction using neural network and spline interpolation
Ghosal, P., Himavathi, S., & Srinivasan, E. (2020) · International Conference on Smart Structures and Systems (ICSSS) · doi:10.1109/icsss49621.2020.9202214 · Cited by 7
Low-frequency variability in photoplethysmography and autonomic function assessment
Allen, J., & Chen, F. (2022) · Photoplethysmography · doi:10.1016/b978-0-12-823374-0.00008-6 · Cited by 3
Baseline Values of the Compensatory Reserve Index in a Healthy Pediatric Population
Franco, S. R., Morgan, G. J., Lara, C., & Zablah, J. E. (2021) · Pediatric Cardiology · doi:10.1007/s00246-021-02725-8 · Cited by 7
Research on recognition and classification of pulse signal features based on EPNCC
Chen, H., Guo, C., Wang, Z., & Wang, J. (2022) · Scientific Reports · doi:10.1038/s41598-022-10808-6 · Cited by 7
The nonlinearity properties of pulse signal of pregnancy in the three trimesters
Li, N., Yu, J., Mao, X., Zhao, Y., & Huang, L. (2022) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2022.104158 · Cited by 7
Flexible photoplethysmographic sensing devices for intelligent medical treatment
Wu, W., Wang, L., & Shen, G. (2022) · Journal of Materials Chemistry C · doi:10.1039/d2tc03318f · Cited by 7
Mishra, B., & Nirala, N. (2023) · Research on Biomedical Engineering · doi:10.1007/s42600-023-00287-7 · Cited by 7
Chakraborty, P., & Tharini, C. (2024) · Wireless Personal Communications · doi:10.1007/s11277-024-11070-x · Cited by 7
An adaptive delineator for photoplethysmography waveforms
Soundararajan, M., Sivasubramanian, A., & Swarnalatha, A. (2016) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2015-0190 · Cited by 7
CAD Patient Classification Using MIMIC-II
Dey, S., Biswàs, S., Pal, A., Mukherjee, A., Garain, U., & Mandana, K. M. (2016) · Lecture notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering · doi:10.1007/978-3-319-49655-9_44 · Cited by 8
Subramanian, B., & Jeevitha, P. (2017) · International Conference on Advanced Computing and Communication Systems (ICACCS) · doi:10.1109/icaccs.2017.8014561 · Cited by 7
Direct-Global Separation for Improved Imaging Photoplethysmography
Park, J., Sabharwal, A., & Veeraraghavan, A. (2018) · IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw.2018.00186 · Cited by 7
A Contactless Healthcare System with Face Recognition
Lin, J.-W., Lu, M.-H., & Lin, Y. (2019) · International Conference on Intelligent Green Building and Smart Grid · doi:10.1109/igbsg.2019.8886237 · Cited by 7
Abnormal photoplethysmography waveforms are associated with chemotherapy induced neuropathy
Bryce, Y. C. D., Santos-Martin, E., Ziv, E., Gonzalez‐Aguirre, A. J., Moussa, A. M., Friedman, A., & Maybody, M. (2022) · VASA · doi:10.1024/0301-1526/a000987 · Cited by 7
Susana, E., & Ramli, K. (2021) · International Conference on Quality in Research (QiR): International Symposium on Electrical and Computer Engineering · doi:10.1109/qir54354.2021.9716164 · Cited by 7
Fine, J. N., McShane, M. J., Coté, G. L., & Scully, C. G. (2022) · Biosensors · doi:10.3390/bios12080598 · Cited by 7
A low-cost, camera-based continuous PPG monitoring system using Laplacian pyramid
Patil, O. R., Wang, W., Gao, Y., Xu, W., & Jin, Z. (2018) · Smart Health · doi:10.1016/j.smhl.2018.07.024 · Cited by 7
Non-invasive Calibration-Free Blood Pressure Estimation Based on Artificial Neural Network
Maher, N., El-Sheikh, G., Anis, W. R., & Emara, T. (2019) · Advances in intelligent systems and computing · doi:10.1007/978-3-030-14118-9_69 · Cited by 7
Kock, K. D. S., da Silva, J. B. F., & Marques, J. L. B. (2019) · Jornal Vascular Brasileiro · doi:10.1590/1677-5449.180084 · Cited by 7
Design of a non-invasive pulse rate controlled deep vein thrombosis prophylaxis lower limb device
Vinay, C. K., Vazhiyal, V., & Rao, M. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8856441 · Cited by 7
Photoplethysmography: New trends and future directions
Kyriacou, P. A., & May, J. M. (2022) · Photoplethysmography · doi:10.1016/b978-0-12-823374-0.00012-8 · Cited by 6
Ho, Y.-C., Lin, T., Wang, S., Chang, C.-H., & Lin, Y.-T. (2024) · Physiological Measurement · doi:10.1088/1361-6579/ad7779 · Cited by 6
Parikh, A., Lewis, G. N., GholamHosseini, H., Rashid, U., Rice, D., & Almesfer, F. (2025) · Sensors · doi:10.3390/s25051485 · Cited by 6
Li, J., Zhang, H., Zhang, Z., Zhang, H., Yang, X., & Yang, J. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3548805 · Cited by 6
Estimating blood pressure using video-based PPG and deep learning
Zaza, G., Casalino, G., Caputo, S. L., & Castellano, G. (2025) · Image and Vision Computing · doi:10.1016/j.imavis.2025.105683 · Cited by 6
Wrist-Worn Devices for Remote Monitoring of Cardiovascular Disease: A Survey
Sadiq, I., Ijaz, A., & Imran, A. (2025) · IEEE Access · doi:10.1109/access.2025.3602893 · Cited by 7
Cassani, R., Tiwari, A., & Falk, T. H. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9175396 · Cited by 6
Vascular age acquired from the pulse signal: A new index to screen early vascular aging
Tang, Q., Pan, Z., Tao, C., Jiang, J., Su, B., An, H., Liu, G., & Pan, Z. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.106355 · Cited by 6
Automated myocardial infarction and angina detection using second derivative of photoplethysmography
Neha, N., Sardana, H. K., Dahiya, N., Dogra, N., Kanawade, R. V., Sharma, Y. P., & Kumar, S. (2023) · Physical and Engineering Sciences in Medicine · doi:10.1007/s13246-023-01293-w · Cited by 6
Hao, Z. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3307877 · Cited by 7
Deep learning classification of systemic sclerosis from multi-site photoplethysmography signals
Iqbal, S., Bacardit, J., Griffiths, B., & Allen, J. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2023.1242807 · Cited by 7
Securing Pacemakers Using Runtime Monitors over Physiological Signals
Panda, A., Pinisetty, S., & Roop, P. S. (2024) · ACM Transactions on Embedded Computing Systems · doi:10.1145/3638286 · Cited by 6
MEMS Fingertip Strain Plethysmography for Cuffless Estimation of Blood Pressure
Shokouhmand, A., Jiang, X., Ayazi, F., & Ebadi, N. (2024) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3372968 · Cited by 6
Preserving privacy and video quality through remote physiological signal removal
Bhutani, S., Elgendi, M., & Menon, C. (2025) · Communications Engineering · doi:10.1038/s44172-025-00363-z · Cited by 6
Self-citationKIMS, K., & Dr Amit Kumar, M. D. (2017) · Journal of Medical Science And clinical Research · doi:10.18535/jmscr/v5i1.11 · Cited by 6
Assessment of Arterial Stiffness Index Calculated from Accelerated Photoplethysmography
Murakami, T., Asai, K., Kadono, Y., Nishida, T., Nakamura, H., & Kishima, H. (2019) · Artery Research · doi:10.2991/artres.k.191120.001 · Cited by 6
Physiological parameter measurement using wearable sensors and cloud computing
Mary, X. A., Mohan, S., Evangeline, C. S., & Rajasekaran, K. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-819779-0.00002-2 · Cited by 6
Fabricating Novel PDMS Vessels for Phantoms in Photoplethysmography Investigations
Nomoni, M., May, J. M., & Kyriacou, P. A. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176476 · Cited by 6
Machine Learning Approach for Contactless Photoplethysmographic Measurement Verification
Semchuk, I. P., Muravskaya, N. P., Zlobin, K. D., & Samorodov, A. V. (2021) · Lecture notes in computer science · doi:10.1007/978-3-030-68821-9_8 · Cited by 6
PPGTempStitch: A MATLAB Toolbox for Augmenting Annotated Photoplethsmogram Signals
Tang, Q., Chen, Z., Menon, C., Ward, R. K., & Elgendi, M. (2021) · Sensors · doi:10.3390/s21124007 · Cited by 6
Self-citationDhar, S., Chakraborty, A., Sadhukhan, D., Pal, S., & Mitra, M. (2022) · Sadhana · doi:10.1007/s12046-021-01781-3 · Cited by 6
Metadata
- Authors
- Elgendi, M.
- Affiliations
- Charles Darwin University (AU)
- Corresponding author
- Elgendi, Mohamed
- ORCID
- Elgendi, Mohamed
- Venue
- Current Cardiology Reviews
- Publisher
- Bentham Science Publishers Ltd.
- Published
- 2012-06-01
- Volume
- 8
- Issue
- 1
- Pages
- 14-25
- ISSN
- 1573-403X (ISSN-L)
- PMC
- PMC3394104
- OpenAlex
- W1981918735
- Cited by
- 1,206
- References
- 88
- Citations by year
- 2026: 120 · 2025: 106 · 2024: 116 · 2023: 109 · 2022: 130 · 2021: 114 · 2020: 118 · 2019: 118 · 2018: 86 · 2017: 65 · 2016: 46 · 2015: 42 · 2014: 24 · 2013: 11 · 2012: 1
- FWCI
- 2.17
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Current Cardiology Reviews (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DR-NTU (Nanyang Technological University) (submittedVersion)
- Funders
- Univerzita Karlova v Praze
- Australian Government
- Charles Darwin University
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- photoplethysmography, digital volume pulse, aging, autonomic function, blood pressure, heart rate, pulse wave analysis, cardiovascular disease, vascular disease, atherosclerosis screening
- MeSH terms
- Fingers, Hemodynamics, Humans, Skin, Artifacts, Photoplethysmography, Pulse Wave Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review