Biodegradable synthetic polymers for tissue engineering
Open accessThe DOI matches its Crossref record; 96 of the 97 references it cites were found in a registry or an index; 1 of the 146 sources its claims cite were checked for support.
Abstract
This review focuses on biodegradable synthetic polymers, discussing synthesis, properties and biodegradability, especially within the polyester family including polylactides.
Overview
CoChat Summary
TL;DR
This review surveys biodegradable synthetic polymers for tissue engineering, emphasizing polyesters (PGA, PLA, PLGA), polylactones, poly(propylene fumarate), polyanhydrides, tyrosine-derived polycarbonates, polyorthoesters, polyurethanes, and polyphosphazenes. It concludes that polyesters dominate clinically, while injectable in situ curable systems such as PPF and photocrosslinkable polyanhydrides are promising but face challenges in biocompatibility, degradation control, and heat generation.
Key findings
- Polyesters are the most studied biodegradable polymers. PGA has 46–50% crystallinity, Tg 36°C, Tm 225°C; in Dexon sutures in vitro, first-stage degradation predominates for 21 days, crystalline degradation takes a further 28 days, and after 49 days weight loss was about 42% with complete loss of mechanical properties.
- PLA/PGA copolymer behavior depends on composition: 25–75% (l)LA/GA and 0–70% (dl)LA/GA are amorphous; 70/30 GA/LA has the highest water uptake, while 50/50 is reported as most unstable to hydrolysis; Vicryl is 8% (l)LA and 92% GA.
- Poly(caprolactone) degrades slowly: homopolymer degradation is on the order of 2–3 years, and PCL with initial average molecular weight 50,000 takes about 3 years for complete in vitro degradation.
- Poly(propylene fumarate) degrades to fumaric acid and propylene glycol; time to 20% original weight loss ranged from 84 days (PPF/β-TCP composite) to over 200 days (PPF/CaSO4 composite). PPF formulations showed maximum curing temperatures of 38–48°C versus 94°C for PMMA cements, curing times of 1–121 min, and compressive strengths of 1–12 MPa.
- Polyanhydrides degrade by surface erosion; poly(sebacic acid) degrades in about 54 days in saline, while poly(1,6-bis(p-carboxyphenoxy)hexane) is estimated at 1 year. Poly[1,6-bis(carboxyphenoxy)hexane] has a Young’s modulus of 1.3 MPa versus human bone at 40–60 MPa; poly(anhydride-co-imides) reached compressive strengths of 50–60 MPa, and photocrosslinked systems showed compressive strengths of 30–40 MPa and tensile strengths of 15–27 MPa.
- Degradable polyurethanes based on lysine diisocyanate showed varied properties: dl-lactide networks were rigid (Tg = 60°C) with ultimate tensile strengths of ~40–70 MPa, caprolactone triol networks were low-modulus elastomers with tensile strengths of 1–4 MPa, and copolymer networks had elongation up to 600% with compressive strengths of 3–25 MPa. In vivo, porous polyurethane artificial skin degraded almost completely 4–8 weeks after implantation in guinea pigs with no adverse tissue reaction.
Methods
- Design: narrative literature review; no primary experimental study or systematic review protocol is reported.
- Data/sample: published literature on biodegradable synthetic polymers, including synthesis, properties, degradation, biocompatibility, and injectable polymer systems; Tables 1–3 summarize polymer properties and precursors.
- Analysis: qualitative synthesis of major polymer classes, their degradation modes/products, mechanical properties, biocompatibility, and potential for injectable tissue-engineering compositions.
Limitations
- Stated: the paper notes that Table 2 data “should be used as a guide only” and that sufficient data are not available to provide a comprehensive list of properties for polyanhydrides, polycarbonates, polyurethanes, and polyphosphazenes.
- Stated: for polyanhydrides, no data are reported about polymer sterilizability and heat generation during polymerization; for degradable polyurethanes, the effect of degradation products and how they are removed from the body are not clearly understood.
- Evident: as a narrative review, it lacks systematic search criteria, study quality appraisal, and meta-analysis, so conclusions depend on the cited literature and may not comprehensively cover all biodegradable polymers or tissue-engineering applications.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
1 Valid · 20 Not valid · 105 Not checked · 89 Own results and interpretations
Every source the paper cites for this claim was checked and supports it.
In the paper
“A meniscal replica implanted contained only fibro-cartilage after 18 weeks and decreased the degradation of the articular cartilage.”
What the sources say
- Supportedcites De Groot et al.., 1996 source
The Aliphatic PU network passage (page not provided) reports that articular-cartilage degeneration was less severe with the prosthesis than in meniscectomized control knees. It also says the prostheses contained only fibrocartilage after 18 weeks. Degeneration was reduced, not eliminated. (LLM, conf=0.91)
plainstates a causeSingle case- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
In the paper
“The compressive strengths varied between 1 and 12 MPa”
What the sources say
- Not matchedcites Peter et al., 1998a
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Cross-linking characteristics reported for PPF, N-vinyl pyrrolidone (N-VP), benzoyl peroxide, sodium chloride, and TCP indicate that for a range of formulations, the maximum temperature varied within 38 to about 48ºC, compared to 94ºC observed for polymethylmethacrylate (PMMA) cements.”
What the sources say
- Not matchedcites Peter et al., 1998a
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
hedged- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper in Crossref, so there is nothing to check it against.
In the paper
“Based on in-vitro studies, the time required to reach 20% loss in original weight ranged from 84 (PPF/ß-TCP composite) to over 200 days (PPF/CaSO 4 composite)”
What the sources say
- Not matchedcites Peter et al., 1997b
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Not matchedcites Kharas et al., 1997
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“These composite materials exhibit compressive strengths in the range 2 to 30 MPa.”
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
94 more claims
Create a free account to see all 215 claims and to verify the 2 references still open.
- It may state two separate claims as one. 62
- Probably not a substantial claim. 76
- The quote only partly states this claim. 1
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Advantages include a tightly controlled manufacturing process, accurate reproducibility, adjustable biodegradability, and a wide variety of both chemical and physical properties.[ 171 ]”
From Unraveling and Harnessing the Immune Response at the Cell–Biomaterial Interface for Tissue Engineering Purposes (2024) · cites this paper as [171]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
In the paper
§ Polyanhydrides
“Polyanhydrides degrades by surface erosion (Kohn and Langer, 1997) and their main applications are in controlled drug delivery.”
§ Conclusions
“Polyanhydride degrade by bulk erosion and their main applications are in controlled drug delivery.”
Citations
Cites
Synthetic biodegradable polymers as orthopedic devices
Middleton, J. C., & Tipton, A. J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00101-0 · Cited by 2,741 · cited 4×
“…developments in siloxane-based polyurethanes, which have greater in-vivo stability than conventional polyetherurethanes (e.g., poly(tetramethylene oxide) (PTMO)-based) have provided opportunities for development of a range of medical implants for chronic applications (Gunatillake et al., 2001).”
BackgroundInfluentialBiomaterial developments for bone tissue engineering
Burg, K. J. L., Porter, S., & Kellam, J. F. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00102-2 · Cited by 1,643 · cited 1×
“Polyesters have also been considered for development of tissue engineering applications (Hubbell, 1995; Thomson et al 1995a, Yazemski et al. 1996; Wong and Mooney, 1997), particularly for bone tissue engineering (Kohn and Langer, 1997; Burg et al., 2000).”
BackgroundChandra, R. (1998) · Progress in Polymer Science · doi:10.1016/s0079-6700(97)00039-7 · Cited by 1,462
Biodegradable polymers for use in surgery—polyglycolic/poly(actic acid) homo- and copolymers: 1
Gilding, D. K., & Reed, A. M. (1979) · Polymer · doi:10.1016/0032-3861(79)90009-0 · Cited by 1,345
Biomaterials in Tissue Engineering
Hubbell, J. A. (1995) · Nature Biotechnology · doi:10.1038/nbt0695-565 · Cited by 1,060 · cited 1×
“Polyesters have also been considered for development of tissue engineering applications (Hubbell, 1995; Thomson et al 1995a, Yazemski et al. 1996; Wong and Mooney, 1997), particularly for bone tissue engineering (Kohn and Langer, 1997; Burg et al., 2000).”
BackgroundPolylactic Acid for Surgical Implants
KULKARNI, R. K. (1966) · Archives of Surgery · doi:10.1001/archsurg.1966.01330050143023 · Cited by 841
Evolution of bone transplantation: molecular, cellular and tissue strategies to engineer human bone
Yaszemski, M. J., Payne, R. G., Hayes, W. C., Langer, R., & Mikos, A. G. (1996) · Biomaterials · doi:10.1016/0142-9612(96)85762-0 · Cited by 729
Miller, R. A., Brady, J. M., & Cutright, D. E. (1977) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820110507 · Cited by 722 · cited 2×
“For the (l)LA/GA copolymers, resistance to hydrolysis is more pronounced at either end of the copolymers compositions range (Miller et al., 1977; Gilding and Reed, 1979; Reed and Gilding, 1981; Vert et al., 1984).”
BackgroundInjectable biodegradable materials for orthopedic tissue engineering
Temenoff, J. S., & Mikos, A. G. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00108-3 · Cited by 554 · cited 8×
“A number of methods have been reported to prepare PPF, and each results in different polymer properties (Peter et al., 1997a,b, 1999; Temenoff and Mikos 2000).”
BackgroundMethodInfluentialLeong, K. W., Brott, B. C., & Langer, R. (1985) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820190806 · Cited by 541 · cited 12×
“The polyurethanes ranged from elastomers with elongations at break as high as 780 %, but with low tensile strengths (5.8 to 8.1 MPa).”
BackgroundInfluential
Research works printed but not linked: 5
- Scranton A, Bowman C, Peiffer R, eds. ACS Symposium Series 673; American Chemical Society, Washington DC. pp 189-202.
- Ratner BD, Hoffman AS, Schoen FJ, Lemon JE, eds. Aca- demic Press, San Diego. pp 65-73.
- Lamba NMK, Woodhouse KA, Cooper SL (1998) Poly- urethanes in Biomedical Applications. CRC Press: New York p 205-241.
- Mark JE, Alcock HR, West R (1992) Inorganic Poly- mers. Prentice Hall, Upper Saddle River, NJ. Chapter
- Ng SY, Vandamme T, Tayler MS, Heller J (1997) Syn- thesis and erosion studies of self-catalysed poly(orthoester)s. Macromolecules 30: 770-772.
Cited by
Items 501–600 of 1,762
Griffithsin-Modified Electrospun Fibers as a Delivery Scaffold To Prevent HIV Infection
Grooms-Williams, T. W., Vuong, H. R., Tyo, K. M., Malik, D. A., Sims, L. B., Whittington, C. P., Palmer, K. E., Matoba, N., & Steinbach-Rankins, J. M. (2016) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.00956-16 · Cited by 43
“Furthermore, due to the variety of polymers available, virtually any compound can be incorporated, and delivery durations can be altered to suit the specific delivery requirements of a topical delivery vehicle (87, 88).”
BackgroundThe Good the Bad and the Ugly of Glycosaminoglycans in Tissue Engineering Applications
Ayerst, B. I., Merry, C. L. R., & Day, A. J. (2017) · Pharmaceuticals · doi:10.3390/ph10020054 · Cited by 48
“PLA contains a methyl side group within each monomer unit, which contributes to its hydrophobicity and slower degradation rate compared to PGA [385].”
BackgroundResultInfluentialMahboudi, H., Kazemi, B., Soleimani, M., et al. (2017) · Gene · doi:10.1016/j.gene.2017.11.073 · Cited by 42
Später, T., Mariyanats, A. O., Syachina, M. A., Mironov, A. V., Savelyev, A. G., Sochilina, A. V., Menger, M. D., Vishnyakova, P., Kananykhina, E. Y., Fatkhudinov, T., et al. (2020) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.0c00741 · Cited by 43
Optimization of polyurethane membranes
Melnig, V., Apostu, M., Ţura, V., & Ciobanu, C. (2005) · Journal of Membrane Science · doi:10.1016/j.memsci.2005.04.054 · Cited by 42
Ishihara, T., Takahashi, M., Higaki, M., Mizushima, Y., & Mizushima, T. (2009) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2009.10.025 · Cited by 45
Laminated collagen-fiber bio-composites for soft-tissue bio-mimetics
Sharabi, M., Benayahu, D., Benayahu, Y., Isaacs, J. L., & Haj-Ali, R. M. (2015) · Composites Science and Technology · doi:10.1016/j.compscitech.2015.06.024 · Cited by 41
A Sustainable Solution to Skin Diseases: Ecofriendly Transdermal Patches
Yilmaz, E. G., Ece, E., Erdem, Ö., Eş, İ., & İnci, F. (2023) · Pharmaceutics · doi:10.3390/pharmaceutics15020579 · Cited by 47
“These next-generation polymers are obtained from nonedible and highly accessible plants as well as agro-food and industrial by-products [24].”
BackgroundBiodegradable synthetic polymers in sustainable corrosion protection: Present and future scenarios
Verma, C., Quraishi, M. A., Alfantazi, A. M., & Rhee, K. Y. (2023) · Advanced Industrial and Engineering Polymer Research · doi:10.1016/j.aiepr.2023.04.005 · Cited by 62
Amato, I., Ciapetti, G., Pagani, S., Marletta, G., Satriano, C., Baldini, N., & Granchi, D. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.04.038 · Cited by 49
Combinatorial Approach to Develop Tailored Biodegradable Poly(xylitol dicarboxylate) Polyesters
Dasgupta, Q., Chatterjee, K., & Madras, G. (2014) · Biomacromolecules · doi:10.1021/bm5013025 · Cited by 42
Modified electrospun chitosan membranes for controlled release of simvastatin
Murali, V. P., Fujiwara, T., Gallop, C., et al. (2020) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2020.119438 · Cited by 41
“Generally, drug release from polymer-based systems depends on initial drug loading amount, polymer-drug interactions, polymer degradability and the extent of diffusion [48].”
BackgroundMaterials-based nanotherapeutics for injured and diseased bone
Lee, C., Singh, R. K., Hwang, H. S., Lee, N., Kurian, A. G., Lee, J., Kim, H., Lee, M., & Kim, H. (2023) · Progress in Materials Science · doi:10.1016/j.pmatsci.2023.101087 · Cited by 43
In vitro hydroxyapatite forming ability and dissolution of tobermorite nanofibers
Lin, K., Chang, J., & Cheng, R. (2007) · Acta Biomaterialia · doi:10.1016/j.actbio.2006.11.003 · Cited by 41
Designing porosity and topography of poly(1,3-trimethylene carbonate) scaffolds
Papenburg, B. J., Schüller-Ravoo, S., Bolhuis‐Versteeg, L. A. M., Hartsuiker, L., Grijpma, D. W., Feijén, J., Weßling, M., & Stamatialis, D. F. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.05.017 · Cited by 46
“co-polymers have been intensively studied [3,4].”
Osteogenic and chondrogenic potential of biomembrane cells from the PMMA‐segmental defect rat model
Gruber, H. E., Riley, F. E., Hoelscher, G. L., Bayoumi, E. M., Ingram, J. A., Ramp, W. K., Bosse, M. J., & Kellam, J. F. (2012) · Journal of Orthopaedic Research® · doi:10.1002/jor.22047 · Cited by 43
Phosphoester cross-linked vegetable oil to construct a biodegradable and biocompatible elastomer
Liu, Z., Xu, Y., Cao, L., Bao, C., Sun, H., Wang, L., Dai, K., & Zhu, L. (2012) · Soft Matter · doi:10.1039/c2sm25115a · Cited by 46
de Figueiredo, V. L. P. (2013) · Journal of Cosmetic Dermatology · doi:10.1111/jocd.12020 · Cited by 41
Novel calcified gum Arabic porous nano-composite scaffold for bone tissue regeneration
Hadavi, M., Hasannia, S., Faghihi, S. H., Mashayekhi, F., Zadeh, H. H., & Mostofi, S. B. (2017) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2017.03.046 · Cited by 41
Sonseca, Á., & Fray, M. E. (2017) · RSC Advances · doi:10.1039/c7ra02509b · Cited by 42
Doyle, S. E., Henry, L., McGennisken, E., Onofrillo, C., Bella, C. D., Duchi, S., O’Connell, C. D., & Pirogova, E. (2021) · Polymers · doi:10.3390/polym13020295 · Cited by 46
Wang, Q., Chen, G. Q., Lin, L., Li, X., & Kentish, S. E. (2021) · Separation and Purification Technology · doi:10.1016/j.seppur.2021.119739 · Cited by 40
Zhou, J., Wang, X., Hua, K., Duan, C., Zhang, W., Ji, J., & Yang, X. (2013) · Iranian Polymer Journal · doi:10.1007/s13726-013-0124-8 · Cited by 41
“The desirable characteristics compared with those of non-degradable materials include no stress shielding effect [3], no need for secondary surgery exposure to remove devices, and easy molding into various shapes [4, 5].”
BackgroundPreclinical Evaluation of Bioabsorbable Polyglycolic Acid Spacer for Particle Therapy
Akasaka, H., Sasaki, R., Miyawaki, D., Mukumoto, N., Sulaiman, N. S., Nagata, M., Yamada, S., Murakami, M., Demizu, Y., & Fukumoto, T. (2014) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2014.07.048 · Cited by 42
“The process for producing the nonwoven fabric involves entangling threads in 3 dimensions using a needle punching process and other methods (19, 20).”
BackgroundMethodPascual-González, C., de la Vega, J., Thompson, C., Fernandéz‐Blázquez, J. P., Herráez-Molinero, D., Biurrun, N., Lizarralde, I., del Río, J. S., González, C., & LLorca, J. (2022) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2022.105290 · Cited by 44
“Among biodegradable polymers, poly-lactic acid (PLA) is one of the most widely used and it has been approved by the Food and Drug Administration (FDA) of the United States for implantation in the human body for tissue fixation devices and drugdelivery systems (Gunatillake and Adhikari, 2003; Maurus and Kaeding, 2004;…”
Biomaterials in Traumatic Brain Injury: Perspectives and Challenges
Aqel, S., Al‐Thani, N. A., Haider, M. Z., Abdelhady, S., Thani, A. A. A., Kobeissy, F. H., & Shaito, A. A. (2023) · Biology · doi:10.3390/biology13010021 · Cited by 47
“In vivo, synthetic polymers lack intrinsic biological properties, and their breakdown products may have negative effects or impact the local microenvironment [208].”
BackgroundDai, X., Nie, W., Shen, H., Machens, H., Böker, K. O., Taheri, S., Lehmann, W., Shen, Y., & Schilling, A. F. (2024) · Regenerative Biomaterials · doi:10.1093/rb/rbae139 · Cited by 55
Polyphophazenes as anti-cancer drug carriers: From synthesis to application
Akram, M. A., Wang, L., Yu, H., Amer, W. A., Khalid, H., Abbasi, N. M., Chen, Y., Ul-Abdin, Z., Saleem, M., & Tong, R. (2014) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2014.07.009 · Cited by 38
Leszczak, V., Place, L. W., Franz, N., Popat, K. C., & Kipper, M. J. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am501700e · Cited by 41
Bioreabsorbable polymers for tissue engineering: PLA, PGA, and their copolymers
Benatti, A. C. B., Pattaro, A. F., Rodrigues, A. A., Xavier, M. V., Kaasi, A., Barbosa, M. I. R., Jardini, A. L., Filho, R. M., & Kharmandayan, P. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-816901-8.00004-3 · Cited by 55
Ghosal, K., & Sarkar, K. (2019) · New Journal of Chemistry · doi:10.1039/c9nj02940k · Cited by 38
Prasad, A. (2021) · Materials Today Proceedings · doi:10.1016/j.matpr.2020.12.489 · Cited by 44
Zhao, J., Duan, K., Zhang, J. W., et al. (2010) · Applied Surface Science · doi:10.1016/j.apsusc.2010.02.053 · Cited by 39
An overview of translational research in bone graft biomaterials
Kumawat, V. S., Bandyopadhyay‐Ghosh, S., & Ghosh, S. B. (2022) · Journal of Biomaterials Science Polymer Edition · doi:10.1080/09205063.2022.2127143 · Cited by 42
“Additionally, owing to high crystallinity, PGA is insoluble in majority of organic solvents except to the highly toxic hexafluoroisopropanol (HFIP) solvent [215].”
BackgroundBoccafoschi, F., Mosca, C., & Cannas, M. F. (2012) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.1526 · Cited by 40
“Degradation rate depends on factors such as conformational structure, molecular weight, morphology, crystallinity, stresses, copolymer ratio, amount of residual monomer, porosity and site of implantation (Gunatillake and Adhikari, 2003).”
BackgroundInfluentialMano, J. F. (2014) · Materials Letters · doi:10.1016/j.matlet.2014.11.061 · Cited by 38
“In the last 20 years strong efforts have been devoted to the preparation and use of different macromolecules, either synthetic [20] or natural-based [21], as structural building blocks in TE, often based on biomaterials previously proposed for other biomedical applications.”
BackgroundFiroozi, N., Rezayan, A. H., Rezaei, S. J. T., Mir‐Derikvand, M., Nabid, M. R., Nourmohammadi, J., & Arough, J. M. (2017) · International Journal of Polymeric Materials · doi:10.1080/00914037.2016.1276059 · Cited by 42
Production of 3D printed polylactide scaffolds with surface grafted hydrogel coatings
Kowalczyk, P., Trzaskowska, P. A., Łojszczyk, I., Podgórski, R., & Ciach, T. (2019) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2019.03.069 · Cited by 38
Pourbashir, S., Shahrousvand, M., & Ghaffari, M. (2019) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2019.09.101 · Cited by 38
Ramezani, M. R., Ansari‐Asl, Z., Hoveizi, E., & Kiasat, A. R. (2020) · Fibers and Polymers · doi:10.1007/s12221-020-9523-6 · Cited by 38
Chow, T., Wutami, I., Lucarelli, E., Choong, P., Duchi, S., & Bella, C. D. (2020) · Tissue Engineering Part B Reviews · doi:10.1089/ten.teb.2020.0254 · Cited by 45
“98 Bioceramics are also characterized by their high mechanical stiffness, brittleness, low elasticity, and good biocompatibility, which facilitate differentiation and proliferation of osteoblasts.”
Barkestani, M. N., Naserian, S., Uzan, G., & Shamdani, S. (2021) · Journal of Tissue Engineering · doi:10.1177/2041731420983562 · Cited by 42
Yamada, S., Yassin, M. A., Schwarz, T., Mustafa, K. B. E., & Hansmann, J. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.811942 · Cited by 41
“Microporous scaffolds of synthetic polymers, which are preferred in bone tissue engineering for their mechanical strength, formability, biocompatibility and biodegradability, exacerbate the problem because of their high porosity and hydrophobicity (Gunatillake and Adhikari, 2003).”
BackgroundDefinitions of Terms and Types of Biopolymers
Niaounakis, M. (2015) · Elsevier eBooks · doi:10.1016/b978-0-323-35399-1.00001-6 · Cited by 63
Chandorkar, Y., Madras, G., & Basu, B. (2012) · Journal of Materials Chemistry B · doi:10.1039/c2tb00304j · Cited by 37
Lorden, E. R., Miller, K. J., Ibrahim, M. M., Bashirov, L., Hammett, E., Chakraborty, S., Quiles-Torres, C., Selim, M. A., Leong, K. W., & Levinson, H. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.12.025 · Cited by 41
“While traditionally employed natural polymers, such as collagen, are attractive for use as BSEs due to their inherent biocompatibility, their degradation rates are difficult to optimize in practice [44].”
BackgroundChantawong, P., Tanaka, T., Uemura, A., Shimada, K., Higuchi, A., Tajiri, H., Sakura, K., Murakami, T., Nakazawa, Y., & Tanaka, R. (2017) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-017-5999-z · Cited by 42
“It is used in the fabrication of medical devices such as cardiac pace makers and vascular grafts [18, 19].”
MethodChan, J. P. Y., Battiston, K. G., & Santerre, J. P. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.06.046 · Cited by 43
Simpson, C. R., Kelly, H. M., & Murphy, C. M. (2020) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2020.10.011 · Cited by 39
Wang, S., Wang, F., Zhao, X. R., Yang, F., Xu, Y., Yan, F., Xia, D., & Liu, Y. (2022) · Materials & Design · doi:10.1016/j.matdes.2022.110621 · Cited by 39
Diez-Pascual, A. M., & Díez-Vicente, A. L. (2017) · Materials Science and Engineering C · doi:10.1016/j.msec.2017.04.114 · Cited by 37
Nanoparticles as a Therapeutic Delivery System for Skin Cancer Prevention and Treatment
Chang, J., Yu, B., Saltzman, W. M., & Girardi, M. (2023) · JID Innovations · doi:10.1016/j.xjidi.2023.100197 · Cited by 45
“Despite their solid forms, polymers used in biomedical applications are biodegradable; most common polymers degrade by hydrolysis enzymatic cleavage in biological fluids, such that larger molecular-weight polymers become lower in molecular weight over time, thus allowing for controlled release of the therapeutic from…”
BackgroundThree-dimensional cell culture models for investigating human viruses
He, B., Chen, G., & Zeng, Y. (2016) · Virologica Sinica · doi:10.1007/s12250-016-3889-z · Cited by 40
“…applied in tissue engineering to substitute for the natural ECM microstructures and properties (Lutolf and Hubbell, 2005), because of their flexible biophysical and biochemical characteristics, high versatility, reproducibility and good workability (Gunatillake and Adhikari, 2003; Xu et al., 2014).”
BackgroundMahboudi, H., Soleimani, M., Enderami, S. E., et al. (2017) · Artificial Cells Nanomedicine and Biotechnology · doi:10.1080/21691401.2017.1396998 · Cited by 36
Biodegradable polyol-based polymers for biomedical applications
Dasgupta, Q., Madras, G., & Chatterjee, K. (2018) · International Materials Reviews · doi:10.1080/09506608.2018.1505066 · Cited by 36
“These materials are widely used for engineering matrices for tissue development [64,65] and offer individual advantages over one another in specific tissue applications.”
BackgroundUse of Polyesters in Fused Deposition Modeling for Biomedical Applications
Grivet‐Brancot, A., Boffito, M., & Ciardelli, G. (2022) · Macromolecular Bioscience · doi:10.1002/mabi.202200039 · Cited by 47
Li, Y., Shi, Y., Duan, S., Shan, D., Wu, Z., Cai, Q., & Yang, X. (2013) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35065 · Cited by 37
In vivo osteointegration of three-dimensional crosslinked gelatin-coated hydroxyapatite foams
Albarova, J. G., Vila, M., Badiola-Vargas, J., et al. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.06.019 · Cited by 36
Biodegradable Materials in Arthroscopy
Gunja, N. J., & Athanasiou, K. A. (2006) · Sports Medicine and Arthroscopy Review · doi:10.1097/00132585-200609000-00002 · Cited by 41
“PGA has been used extensively as a biodegradable material as its byproduct is a natural metabolite, glycolic acid.(20) PGA implants of varying MW have been fabricated by compression and injection molding.”
MethodJonnala, U. K., Sankineni, R., & Kumar, Y. R. (2023) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2023.106005 · Cited by 45
Huang, B., Yang, M., Kou, Y., & Jiang, B. (2023) · Bioactive Materials · doi:10.1016/j.bioactmat.2023.08.015 · Cited by 40
“However, due to low mechanical strength, large elasticity, and lack of osteogenic bioactivity [30], PLGA cannot be used for load-bearing applications and is rarely used in orthopedics at present [13,31].”
BackgroundDielectric behaviour and pore size distribution of collagen–guar gum composites: Effect of guar gum
Manikoth, R., Kanungo, I., Fathima, N. N., & Rao, J. R. (2012) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2012.01.031 · Cited by 35
Duan, S., Yang, X., Mao, J., Qi, B., Cai, Q., Shen, H. Y., Yang, F., Deng, X., & Wang, S. (2012) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34282 · Cited by 36
Tissue engineering: A new vista in periodontal regeneration
Philips, D., Pandit, N., & Malik, R. (2011) · Journal of Indian Society of Periodontology · doi:10.4103/0972-124x.92564 · Cited by 35
Resorbable Implants for Orbital Fractures: A Systematic Review
Ramesh, S., Hubschman, S., & Goldberg, R. A. (2018) · Annals of Plastic Surgery · doi:10.1097/sap.0000000000001504 · Cited by 38
Srivastava, A., & Kumar, A. (2010) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-010-4124-3 · Cited by 35
“Biocompatible and degradable networks of biomaterials are advantageous in tissue engineering, where a temporary scaffold design is needed for structural support, cell attachment, and growth [1].”
BackgroundChen, L., Wang, H., Wang, J., Chen, M., & Shang, L. (2007) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.30832 · Cited by 37
Radaei, P., Mashayekhan, S., & Vakilian, S. (2017) · Materials Science and Engineering C · doi:10.1016/j.msec.2017.02.108 · Cited by 35
Bikuna‐Izagirre, M., Aldazabal, J., & Paredes, J. (2022) · Polymers · doi:10.3390/polym14071311 · Cited by 35
“The mechanical characteristics and biodegradability rates [13] of synthetic polymers, which are critical features in scaffold design, can be adjusted for each clinical application [4,14].”
BackgroundAsran, A. S., Salama, M. S., Popescu, C., & Michler, G. H. (2010) · Macromolecular Symposia · doi:10.1002/masy.201050814 · Cited by 36
Characterisation and modelling of the elastic properties of poly(lactic acid) nanofibre scaffolds
Gómez-Pachón, E. Y., Sánchez‐Arévalo, F. M., Sabina, F. J., Maciel-Cerda, A., Montiel-Campos, R., Batina, N., Morales-Reyes, I., & Vera‐Graziano, R. (2013) · Journal of Materials Science · doi:10.1007/s10853-013-7644-7 · Cited by 35
Bioengineering of Articular Cartilage: Past, Present and Future
Ye, K., Felimban, R. I., Moulton, S. E., Wallace, G. G., Bella, C. D., Traianedes, K., Choong, P., & Myers, D. E. (2013) · Regenerative Medicine · doi:10.2217/rme.13.28 · Cited by 40
Electrospun polycaprolactone matrices with tensile properties suitable for soft tissue engineering
Elamparithi, A., Punnoose, A. M., Kuruvilla, S., Ravi, M., Rao, S. R., & Paul, S. F. D. (2015) · Artificial Cells Nanomedicine and Biotechnology · doi:10.3109/21691401.2014.998825 · Cited by 35
“PCL matrices tend to have increased stiffness and more rigidity [3], and are more favourable for hard tissue engineering applications [4].”
BackgroundMorral-Ruíz, G., Solans, C., García, M. L., & García, M. J. N. (2012) · Langmuir · doi:10.1021/la204659y · Cited by 34
A comparative study of skin cell activities in collagen and fibrin constructs
Law, J. X., Musa, F. I., Ruszymah, B. H. I., Haj, A. J. E., & Yang, Y. (2016) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2016.05.017 · Cited by 36
“This undesirable 99 characteristic can be altered via the addition of chemical functional groups on the 100 polymer surface (22).”
BackgroundBhaskar, P., Bosworth, L. A., Wong, R., O’Brien, M., Kriel, H., Smit, E., McGrouther, D. A., Wong, J. K. F., & Cartmell, S. H. (2016) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35911 · Cited by 36
“However, this is expected as synthetic polymers are known to illicit an early inflammatory response as the immune system reacts to the presence of a foreign body.(28,29) Notably, the manufacturer and sterilization method did not lead to different levels of inflammation.”
BackgroundZhong, N., Dong, T., Chen, Z., Guo, Y., Shao, Z., & Zhao, X. (2019) · Journal of Biomaterials Applications · doi:10.1177/0885328219845092 · Cited by 36
Mechanics Strategies for Implantation of Flexible Neural Probes
Zhang, S., Wang, C., Linghu, C., Wang, S., & Song, J. (2020) · Journal of Applied Mechanics · doi:10.1115/1.4047858 · Cited by 38
Immuno-modulatory biomaterials as anti-inflammatory therapeutics
Lynch, R. I., & Lavelle, E. C. (2022) · Biochemical Pharmacology · doi:10.1016/j.bcp.2021.114890 · Cited by 38
Biodegradable Polymers in Drug Delivery Systems
Tsung, J., & Burgess, D. J. (2011) · Springer eBooks · doi:10.1007/978-1-4614-0881-9_5 · Cited by 44
Hassani, F. A., & Lee, C. (2015) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2015.2403256 · Cited by 35
Segmented biopolyurethanes for medical applications
Macocinschi, D., Filip, D., Vlad, S., Cristea, M., & Butnaru, M. (2009) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-009-3731-3 · Cited by 35
In vitro degradation of PLLA/nHA composite scaffolds
Dı́az, E., Sandonis, I., Puerto, I., & Ibáñez, I. (2013) · Polymer Engineering and Science · doi:10.1002/pen.23806 · Cited by 35
Ergun, A., Yu, X., Valdevit, A. D. C., Ritter, A., & Kalyon, D. M. (2012) · Tissue Engineering Part A · doi:10.1089/ten.tea.2011.0625 · Cited by 35
Oxygen plasma‐induced conversion of polysiloxane into hydrophilic and smooth SiO x surfaces
Satriano, C., Marletta, G., & Kasemo, B. (2008) · Surface and Interface Analysis · doi:10.1002/sia.2764 · Cited by 34
Biosafe Nanoscale Pharmaceutical Adjuvant Materials
Jin, S., Li, S., Wang, C., Liu, J., Yang, X., Wang, P. C., Zhang, X., & Liang, X. (2014) · Journal of Biomedical Nanotechnology · doi:10.1166/jbn.2014.1898 · Cited by 36
de Melo, F., & Marijnissen-Hofsté, J. (2012) · Dermatology and Therapy · doi:10.1007/s13555-012-0013-7 · Cited by 37
“PCL and CMC individually have an excellent and established biocompatibility profile and have been used successfully in numerous Conformité Européenne marked and US Food and Drug Administration approved medical devices, such as dermal fillers, oral and maxillofacial surgery, wound dressing and controlled drug delivery…”
MethodSchleicher, I., Parker, A. W., Leavesley, D. I., Crawford, R., Upton, Z., & Xiao, Y. (2005) · Tissue Engineering · doi:10.1089/ten.2005.11.1688 · Cited by 34
Surface modified poly( L ‐lactide‐co‐ε‐caprolactone) microspheres as scaffold for tissue engineering
Garkhal, K., Verma, S., Tikoo, K., & Kumar, N. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31150 · Cited by 35
Polymeric Nanocomposite Hydrogel Scaffolds in Craniofacial Bone Regeneration: A Comprehensive Review
Bashir, M. H., Korany, N. S., Farag, D. B. E., Abbass, M. M. S., Ezzat, B. A., Hegazy, R. H., Dörfer, C. E., & El‐Sayed, K. M. F. (2023) · Biomolecules · doi:10.3390/biom13020205 · Cited by 36
“Moreover, their hydrophobic nature makes it difficult for cells to adhere to them, which worsens their osteoinductive properties in the field of bone TE [50].”
BackgroundCharacteristics of Biodegradable Implants
Adeosun, S. O., Lawal, G. I., & Gbenebor, O. P. (2014) · Journal of Minerals and Materials Characterization and Engineering · doi:10.4236/jmmce.2014.22013 · Cited by 44
“The most commonly investigated and widely used synthetic biodegradable polymers are polyglycolide/glycolic acid (PGA), polylactide/lactic acid (PLA) and poly-ε-caprolactone (PCL) [18]-[20].”
BackgroundKim, Y. B., & Kim, G. (2012) · Journal of Materials Chemistry · doi:10.1039/c2jm33036a · Cited by 33
Bertoldi, S., Farè, S., Denegri, M., Rossi, D., Haugen, H. J., Parolini, O., & Tanzi, M. C. (2009) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-009-3953-4 · Cited by 37
Ferreira, J. C. M., Gloria, A., Cometa, S., Coelho, J. F. J., & Domingos, M. A. N. (2017) · Journal of Applied Biomaterials & Functional Materials · doi:10.5301/jabfm.5000363 · Cited by 42
“The degradation time of PCL-containing structures, evaluated by simulating the in vivo conditions, is relatively high and can last up to 4 years (21).”
A Novel Approach for Meniscal Regeneration Using Kartogenin-Treated Autologous Tendon Graft
Huang, H., Xu, H., & Zhao, J. (2017) · The American Journal of Sports Medicine · doi:10.1177/0363546517721192 · Cited by 33
“Besides biologically derived scaffolds, many synthetic polymer scaffolds have been developed, such as polyurethane, polyglycolic acid, polylactic acid, and poly(Ecaprolactone).(8,9) These polymers provide several advantages, such as satisfactory biomechanical properties, versatility, and access to a nearly endless sup…”
BackgroundSelim, O. A., Lakhani, S., Midha, S., Mosahebi, A., & Kalaskar, D. M. (2021) · Tissue Engineering Part B Reviews · doi:10.1089/ten.teb.2020.0355 · Cited by 40
“201 Alternatively, a lower temperature-cooling platform called Low Frozen Deposition Manufacturing (LFDM) was developed to overcome these shortfalls.”
3D-printed Mg-1Ca/polycaprolactone composite scaffolds with promoted bone regeneration
Zhao, X. L., Wang, S., Wang, F., Zhu, Y., Gu, R., Yang, F., Xu, Y., Xia, D., & Liu, Y. (2022) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2022.07.002 · Cited by 33
Vasireddi, R., & Basu, B. (2015) · Rapid Prototyping Journal · doi:10.1108/rpj-12-2013-0123 · Cited by 33
Ariani, M. D., Matsuura, A., Hirata, I., Kubo, T., Kato, K., & Akagawa, Y. (2013) · Dental Materials Journal · doi:10.4012/dmj.2012-257 · Cited by 34
Sathy, B. N., Natarajan, A., Menon, D., Bhaskaran, V. K., Mony, U., & Nair, S. V. (2012) · Biomedical Materials · doi:10.1088/1748-6041/7/6/065001 · Cited by 34
Metadata
- Authors
- CSIRO Molecular Science, B. 1., & Gunatillake, P.
- Corresponding author
- CSIRO Molecular Science, Bag 10, Clayton South MDC, Vic 3169, Australia
- Venue
- European Cells and Materials
- Publisher
- Forum Multimedia Publishing LLC
- Published
- 2003-10-01
- Volume
- 5
- Pages
- 1-16
- ISSN
- 1473-2262 (ISSN-L)
- OpenAlex
- W2106035984
- Cited by
- 1,765
- References
- 97
- Citations by year
- 2026: 43 · 2025: 61 · 2024: 59 · 2023: 80 · 2022: 90 · 2021: 112 · 2020: 102 · 2019: 115 · 2018: 105 · 2017: 128 · 2016: 110 · 2015: 106 · 2014: 110 · 2013: 91 · 2012: 86
- FWCI
- 1.32
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- European Cells and Materials (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Topics
- Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Health Sciences › Medicine › Surgery › Surgical Sutures and Adhesives
- Keywords
- tissue engineering, polyesters, polyglycolic acid, polylactic acid, polyanhydrides, polyphosphazenes, polyurethane, poly(propylene fumarate), injectable polymers, orthopedic tissue engineering, biodegradation, biocompatibility, degradation products
- MeSH terms
- Biocompatible Materials, Models, Chemical, Polymers, Tissue Engineering
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.