Biodegradable synthetic polymers for tissue engineering
Open accessThe DOI matches its Crossref record; 96 of the 97 references it cites were found in a registry or an index; 1 of the 146 sources its claims cite were checked for support.
Abstract
This review focuses on biodegradable synthetic polymers, discussing synthesis, properties and biodegradability, especially within the polyester family including polylactides.
Overview
CoChat Summary
TL;DR
This review surveys biodegradable synthetic polymers for tissue engineering, emphasizing polyesters (PGA, PLA, PLGA), polylactones, poly(propylene fumarate), polyanhydrides, tyrosine-derived polycarbonates, polyorthoesters, polyurethanes, and polyphosphazenes. It concludes that polyesters dominate clinically, while injectable in situ curable systems such as PPF and photocrosslinkable polyanhydrides are promising but face challenges in biocompatibility, degradation control, and heat generation.
Key findings
- Polyesters are the most studied biodegradable polymers. PGA has 46–50% crystallinity, Tg 36°C, Tm 225°C; in Dexon sutures in vitro, first-stage degradation predominates for 21 days, crystalline degradation takes a further 28 days, and after 49 days weight loss was about 42% with complete loss of mechanical properties.
- PLA/PGA copolymer behavior depends on composition: 25–75% (l)LA/GA and 0–70% (dl)LA/GA are amorphous; 70/30 GA/LA has the highest water uptake, while 50/50 is reported as most unstable to hydrolysis; Vicryl is 8% (l)LA and 92% GA.
- Poly(caprolactone) degrades slowly: homopolymer degradation is on the order of 2–3 years, and PCL with initial average molecular weight 50,000 takes about 3 years for complete in vitro degradation.
- Poly(propylene fumarate) degrades to fumaric acid and propylene glycol; time to 20% original weight loss ranged from 84 days (PPF/β-TCP composite) to over 200 days (PPF/CaSO4 composite). PPF formulations showed maximum curing temperatures of 38–48°C versus 94°C for PMMA cements, curing times of 1–121 min, and compressive strengths of 1–12 MPa.
- Polyanhydrides degrade by surface erosion; poly(sebacic acid) degrades in about 54 days in saline, while poly(1,6-bis(p-carboxyphenoxy)hexane) is estimated at 1 year. Poly[1,6-bis(carboxyphenoxy)hexane] has a Young’s modulus of 1.3 MPa versus human bone at 40–60 MPa; poly(anhydride-co-imides) reached compressive strengths of 50–60 MPa, and photocrosslinked systems showed compressive strengths of 30–40 MPa and tensile strengths of 15–27 MPa.
- Degradable polyurethanes based on lysine diisocyanate showed varied properties: dl-lactide networks were rigid (Tg = 60°C) with ultimate tensile strengths of ~40–70 MPa, caprolactone triol networks were low-modulus elastomers with tensile strengths of 1–4 MPa, and copolymer networks had elongation up to 600% with compressive strengths of 3–25 MPa. In vivo, porous polyurethane artificial skin degraded almost completely 4–8 weeks after implantation in guinea pigs with no adverse tissue reaction.
Methods
- Design: narrative literature review; no primary experimental study or systematic review protocol is reported.
- Data/sample: published literature on biodegradable synthetic polymers, including synthesis, properties, degradation, biocompatibility, and injectable polymer systems; Tables 1–3 summarize polymer properties and precursors.
- Analysis: qualitative synthesis of major polymer classes, their degradation modes/products, mechanical properties, biocompatibility, and potential for injectable tissue-engineering compositions.
Limitations
- Stated: the paper notes that Table 2 data “should be used as a guide only” and that sufficient data are not available to provide a comprehensive list of properties for polyanhydrides, polycarbonates, polyurethanes, and polyphosphazenes.
- Stated: for polyanhydrides, no data are reported about polymer sterilizability and heat generation during polymerization; for degradable polyurethanes, the effect of degradation products and how they are removed from the body are not clearly understood.
- Evident: as a narrative review, it lacks systematic search criteria, study quality appraisal, and meta-analysis, so conclusions depend on the cited literature and may not comprehensively cover all biodegradable polymers or tissue-engineering applications.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
1 Valid · 20 Not valid · 105 Not checked · 89 Own results and interpretations
Every source the paper cites for this claim was checked and supports it.
In the paper
“A meniscal replica implanted contained only fibro-cartilage after 18 weeks and decreased the degradation of the articular cartilage.”
What the sources say
- Supportedcites De Groot et al.., 1996 source
The Aliphatic PU network passage (page not provided) reports that articular-cartilage degeneration was less severe with the prosthesis than in meniscectomized control knees. It also says the prostheses contained only fibrocartilage after 18 weeks. Degeneration was reduced, not eliminated. (LLM, conf=0.91)
plainstates a causeSingle case- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
In the paper
“The compressive strengths varied between 1 and 12 MPa”
What the sources say
- Not matchedcites Peter et al., 1998a
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Cross-linking characteristics reported for PPF, N-vinyl pyrrolidone (N-VP), benzoyl peroxide, sodium chloride, and TCP indicate that for a range of formulations, the maximum temperature varied within 38 to about 48ºC, compared to 94ºC observed for polymethylmethacrylate (PMMA) cements.”
What the sources say
- Not matchedcites Peter et al., 1998a
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
hedged- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper in Crossref, so there is nothing to check it against.
In the paper
“Based on in-vitro studies, the time required to reach 20% loss in original weight ranged from 84 (PPF/ß-TCP composite) to over 200 days (PPF/CaSO 4 composite)”
What the sources say
- Not matchedcites Peter et al., 1997b
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Not matchedcites Kharas et al., 1997
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“These composite materials exhibit compressive strengths in the range 2 to 30 MPa.”
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
94 more claims
Create a free account to see all 215 claims and to verify the 2 references still open.
- It may state two separate claims as one. 62
- Probably not a substantial claim. 76
- The quote only partly states this claim. 1
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Advantages include a tightly controlled manufacturing process, accurate reproducibility, adjustable biodegradability, and a wide variety of both chemical and physical properties.[ 171 ]”
From Unraveling and Harnessing the Immune Response at the Cell–Biomaterial Interface for Tissue Engineering Purposes (2024) · cites this paper as [171]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
In the paper
§ Polyanhydrides
“Polyanhydrides degrades by surface erosion (Kohn and Langer, 1997) and their main applications are in controlled drug delivery.”
§ Conclusions
“Polyanhydride degrade by bulk erosion and their main applications are in controlled drug delivery.”
Citations
Cites
Synthetic biodegradable polymers as orthopedic devices
Middleton, J. C., & Tipton, A. J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00101-0 · Cited by 2,741 · cited 4×
“…developments in siloxane-based polyurethanes, which have greater in-vivo stability than conventional polyetherurethanes (e.g., poly(tetramethylene oxide) (PTMO)-based) have provided opportunities for development of a range of medical implants for chronic applications (Gunatillake et al., 2001).”
BackgroundInfluentialBiomaterial developments for bone tissue engineering
Burg, K. J. L., Porter, S., & Kellam, J. F. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00102-2 · Cited by 1,643 · cited 1×
“Polyesters have also been considered for development of tissue engineering applications (Hubbell, 1995; Thomson et al 1995a, Yazemski et al. 1996; Wong and Mooney, 1997), particularly for bone tissue engineering (Kohn and Langer, 1997; Burg et al., 2000).”
BackgroundChandra, R. (1998) · Progress in Polymer Science · doi:10.1016/s0079-6700(97)00039-7 · Cited by 1,462
Biodegradable polymers for use in surgery—polyglycolic/poly(actic acid) homo- and copolymers: 1
Gilding, D. K., & Reed, A. M. (1979) · Polymer · doi:10.1016/0032-3861(79)90009-0 · Cited by 1,345
Biomaterials in Tissue Engineering
Hubbell, J. A. (1995) · Nature Biotechnology · doi:10.1038/nbt0695-565 · Cited by 1,060 · cited 1×
“Polyesters have also been considered for development of tissue engineering applications (Hubbell, 1995; Thomson et al 1995a, Yazemski et al. 1996; Wong and Mooney, 1997), particularly for bone tissue engineering (Kohn and Langer, 1997; Burg et al., 2000).”
BackgroundPolylactic Acid for Surgical Implants
KULKARNI, R. K. (1966) · Archives of Surgery · doi:10.1001/archsurg.1966.01330050143023 · Cited by 841
Evolution of bone transplantation: molecular, cellular and tissue strategies to engineer human bone
Yaszemski, M. J., Payne, R. G., Hayes, W. C., Langer, R., & Mikos, A. G. (1996) · Biomaterials · doi:10.1016/0142-9612(96)85762-0 · Cited by 729
Miller, R. A., Brady, J. M., & Cutright, D. E. (1977) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820110507 · Cited by 722 · cited 2×
“For the (l)LA/GA copolymers, resistance to hydrolysis is more pronounced at either end of the copolymers compositions range (Miller et al., 1977; Gilding and Reed, 1979; Reed and Gilding, 1981; Vert et al., 1984).”
BackgroundInjectable biodegradable materials for orthopedic tissue engineering
Temenoff, J. S., & Mikos, A. G. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00108-3 · Cited by 554 · cited 8×
“A number of methods have been reported to prepare PPF, and each results in different polymer properties (Peter et al., 1997a,b, 1999; Temenoff and Mikos 2000).”
BackgroundMethodInfluentialLeong, K. W., Brott, B. C., & Langer, R. (1985) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820190806 · Cited by 541 · cited 12×
“The polyurethanes ranged from elastomers with elongations at break as high as 780 %, but with low tensile strengths (5.8 to 8.1 MPa).”
BackgroundInfluential
Research works printed but not linked: 5
- Scranton A, Bowman C, Peiffer R, eds. ACS Symposium Series 673; American Chemical Society, Washington DC. pp 189-202.
- Ratner BD, Hoffman AS, Schoen FJ, Lemon JE, eds. Aca- demic Press, San Diego. pp 65-73.
- Lamba NMK, Woodhouse KA, Cooper SL (1998) Poly- urethanes in Biomedical Applications. CRC Press: New York p 205-241.
- Mark JE, Alcock HR, West R (1992) Inorganic Poly- mers. Prentice Hall, Upper Saddle River, NJ. Chapter
- Ng SY, Vandamme T, Tayler MS, Heller J (1997) Syn- thesis and erosion studies of self-catalysed poly(orthoester)s. Macromolecules 30: 770-772.
Cited by
Items 701–800 of 1,762
Liu, T., Ding, X., Lai, D., Chen, Y., Zhang, R., Chen, J., Feng, X., Chen, X., Yang, X., Zhao, R., et al. (2014) · Journal of Materials Chemistry B · doi:10.1039/c4tb00889h · Cited by 25
Dynamic reciprocity in cell–scaffold interactions
Mauney, J. R., & Adam, R. M. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.10.016 · Cited by 27
“Breakdown of natural and synthetic biomaterials is dependent on variety of factors such as configuration, crystallinity, molecular weight, pore size, porosity, biomechanical stresses, and grafting site [64, 74].”
BackgroundCampiglio, C. E., Marcolin, C., & Draghi, L. (2017) · AIMS Materials Science · doi:10.3934/matersci.2017.3.638 · Cited by 26
“Moreover, their degradation products can locally lower pH and have a detrimental effect on regeneration [36].”
BackgroundMaterials in Tendon and Ligament Repair
Miller, K. J., Hsu, J. E., & Soslowsky, L. J. (2011) · Elsevier eBooks · doi:10.1016/b978-0-08-055294-1.00218-x · Cited by 31
3D Bioprinting for Artificial Pancreas Organ
Lee, S. J., Lee, J., Park, Y.-W., & Lee, D. Y. (2018) · Advances in experimental medicine and biology · doi:10.1007/978-981-13-0445-3_21 · Cited by 26
Gaihre, B., Liu, X., Miller, A. L., Yaszemski, M. J., & Lu, L. (2020) · Journal of macromolecular science. Part C, Reviews in macromolecular chemistry and physics/Journal of macromolecular science. Reviews in macromolecular chemistry and physics · doi:10.1080/15583724.2020.1758718 · Cited by 27
“be modified chemically with several bioactive moieties to achieve the required protein and cell interactions with the scaffold.([6]) Currently, aliphatic polyesters, polyanhydrides, polyphosphazenes, polyurethanes, and polyethers are the most applied synthetic polymers for biomedical applications.”
BackgroundRanjbarvan, P., Golchin, A., Azari, A., & Niknam, Z. (2021) · Polymer Bulletin · doi:10.1007/s00289-021-03702-0 · Cited by 25
“Compared to other polymers like polyglycolic acid, poly L-lactic acid, and poly lactic-co-glycolic acid, it has good mechanical strength and elasticity [16, 17].”
BackgroundKannarkat, J. T., Battogtokh, J., Philip, J., et al. (2010) · Journal of Applied Physics · doi:10.1063/1.3357340 · Cited by 25
Overview of Materials for Microfluidic Applications
Roy, E., Pallandre, A., Zribi, B., Horny, M.-C., Delapierre, F. D., Cattoni, A., Gamby, J., & Haghiri‐Gosnet, A. (2016) · InTech eBooks · doi:10.5772/65773 · Cited by 39
“Various technologies, such as printing, soft‐lithography, stereolithography, hot‐embossing, and injection‐molding methods, have been used toward integration [63, 64].”
MethodTyo, K. M., Vuong, H. R., Malik, D. A., Sims, L. B., Alatassi, H., Duan, J., Watson, W. H., & Steinbach-Rankins, J. M. (2017) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2017.08.061 · Cited by 27
Natarajan, J., Movva, S., Madras, G., & Chatterjee, K. (2017) · Materials Science and Engineering C · doi:10.1016/j.msec.2017.03.160 · Cited by 27
Zhang, Q., Zhou, Z., Peng, C., et al. (2017) · Journal of Macromolecular Science Part B · doi:10.1080/00222348.2017.1330132 · Cited by 25
“properties, have been used as scaffolds for cell adhesion and expansion both in vitro and in vivo and to guide tissue regeneration.([4,5]) Poly(lactic-co-glycolic acid) (PLGA), which is biocompatible, biodegradable, and FDAapproved for human applications, has been most widely utilized to fabricate scaffolds and for dr…”
BackgroundGil-Castell, O., Badia-Valiente, J. D., Ontoria‐Oviedo, I., Castellano, D., Marco, B., Rabal, A., Bou, J. J., Serra, À., Monreal, L., Blanes, M., et al. (2018) · Polymer Testing · doi:10.1016/j.polymertesting.2018.01.027 · Cited by 29
1.4.7 The baryon decuplet except (Omega-) (3/2+ states)
Das, D., Zhang, Z., Winkler, T., Mour, M., Günter, C. I., Morlock, M. M., Machens, H., & Schilling, A. F. (2005) · Advances in biochemical engineering, biotechnology · doi:10.1007/10201111_9 · Cited by 28
Mirzaei, A., Saburi, E., Islami, M., Ardeshirylajimi, A., Omrani, M. D., Taheri, M. N., Moghadam, A. S., & Ghafouri‐Fard, S. (2019) · Gene · doi:10.1016/j.gene.2019.01.037 · Cited by 26
Mania, S., Partyka, K., Pilch, J., Augustin, E., Cieślik, M., Ryl, J., Jinn, J., Wang, Y., Michałowska, A., & Tylingo, R. (2019) · Molecules · doi:10.3390/molecules24244532 · Cited by 32
“, PLA breaks down into the lactic acid, which is present in the human body [5].”
BackgroundNeuss, S., Denecke, B., Gan, L., Lin, Q., Bovi, M., Apel, C., Wöltje, M., Dhanasingh, A., Salber, J., Knüchel, R., et al. (2011) · PLoS ONE · doi:10.1371/journal.pone.0023195 · Cited by 26
“. PCL is the most studied degradable polymer of the polyester family”
BackgroundBrito, T. O., Elzubair, A., Araújo, L. S., Camargo, S. S., Souza, J. L. P., & de Almeida, L. H. (2017) · Materials Research · doi:10.1590/1980-5373-mr-2016-1137 · Cited by 25
Safety in immediate reconstitution of poly‐ l ‐lactic acid for facial biostimulation treatment
Bravo, B. S. F., & Carvalho, R. D. M. (2020) · Journal of Cosmetic Dermatology · doi:10.1111/jocd.13597 · Cited by 24
Wang, Q., Chen, G. Q., & Kentish, S. E. (2020) · Journal of Membrane Science · doi:10.1016/j.memsci.2020.118534 · Cited by 24
“In addition, due to their 35 biodegradable properties, there is a growing demand for these compounds in the production of 36 polymeric materials [3].”
BackgroundGradwohl, M., Chai, F., Payen, J., Guerreschi, P., Marchetti, P., & Blanchemain, N. (2021) · Polymers · doi:10.3390/polym13040572 · Cited by 32
Preparation and Characterization of Plasma-Derived Fibrin Hydrogels Modified by Alginate di-Aldehyde
Sanz-Horta, R., Matesanz, A., Jorcano, J. L., Velasco, D., Acedo, P., Gallardo, A., Reinecke, H., & Elvira, C. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms23084296 · Cited by 25
“However, the use of polymers derived from natural sources demonstrates great properties in regard to biocompatibility and biodegradability [6,7].”
BackgroundGrenier, S., Sandig, M., & Mequanint, K. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2009.0057 · Cited by 24
Peng, Q., Jiang, F., Huang, P., Zhou, S., Weng, J., Bao, C., Zhang, C., & Yu, H. (2009) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32408 · Cited by 24
Cells and Biomaterials for Intervertebral Disc Regeneration
Grad, S., Alini, M., Eglin, D., Sakai, D., Mochida, J., Mahor, S., Collin, E. C., Dash, B. C., & Pandit, A. S. (2010) · Synthesis lectures on tissue engineering · doi:10.2200/s00250ed1v01y201006tis005 · Cited by 30
Gugerell, A., Kober, J., Laube, T., Walter, T., Nürnberger, S., Grönniger, E., Brönneke, S., Wyrwa, R., Schnabelrauch, M., & Keck, M. K. (2014) · PLoS ONE · doi:10.1371/journal.pone.0090676 · Cited by 27
“They often show excellent elasticity and can be designed-to-degrade at the same time, which makes them a promising alternative to poly(hydroxy acids) homopolymers or their copolyesters [38,39].”
BackgroundLingual Nerve Microsurgery Outcomes Using 2 Different Conduits: A Retrospective Cohort Study
Wilson, M. T., Chuang, S. K., & Ziccardi, V. B. (2016) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.joms.2016.09.022 · Cited by 25
Current trends in local antibacterial therapy of periprosthetic infection and osteomyelitis
Божкова, С. А., Novokshonova, A. A., & Konev, V. A. (2015) · Traumatology and Orthopedics of Russia · doi:10.21823/2311-2905-2015-0-3-92-107 · Cited by 24
Review on polyphosphazenes-based materials for bone and skeleton tissue engineering
Khalid, Z., Ali, S., & Akram, M. A. (2017) · International Journal of Polymeric Materials · doi:10.1080/00914037.2017.1375495 · Cited by 25
Kısasöz, B. Ö., & Serhatlı, İ. E. (2020) · Materials Technology · doi:10.1080/10667857.2020.1824149 · Cited by 24
Ercan, B., & Webster, T. J. (2014) · CRC Press eBooks · doi:10.1201/b17444-8 · Cited by 25
del‐Mazo‐Barbara, L., Gómez-Cuyàs, J., Orozco, L. I. M., Pérez, O. O. S., Bou‐Petit, E., & Ginebra, M. (2024) · Polymer Testing · doi:10.1016/j.polymertesting.2024.108566 · Cited by 29
Khan, T., Vadivel, G., Ayyasamy, K., Murugesan, G., & Sebaey, T. A. (2025) · Polymers · doi:10.3390/polym17050620 · Cited by 28
Takashima, K., Hoshino, M., Uesugi, K., Yagi, N., Matsuda, S., Nakahira, A., Osumi, N., Kohzuki, M., & Onodera, H. (2014) · Journal of Synchrotron Radiation · doi:10.1107/s160057751402270x · Cited by 25
Synthesis, Characterization, and Visible Light Curing Capacity of Polycaprolactone Acrylate
Tzeng, J.-J., Hsiao, Y.-T., Wu, Y.-C., Chen, H., Lee, S., & Lin, Y. (2018) · BioMed Research International · doi:10.1155/2018/8719624 · Cited by 23
Szarlej, P., Carayon, I., Gnatowski, P., et al. (2021) · Materials · doi:10.3390/ma14206054 · Cited by 23
Beldjilali‐Labro, M., Jellali, R., Brown, A. D., Garcia, A. G., Lerebours, A., Guénin, E., Bédoui, F., Dufresne, M., Stewart, C. E., Grosset, J.-F., et al. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms23010260 · Cited by 26
“The PCL electrospinning process was tuned to produce matrices with fiber diameters of around 700 nm, to be similar to individual myofibrils (1 μm) [29,30].”
MethodThe comprehensive on-demand 3D bio-printing for composite reconstruction of mandibular defects
Park, H.-I., Lee, J.-H., & Lee, S. J. (2022) · Maxillofacial Plastic and Reconstructive Surgery · doi:10.1186/s40902-022-00361-7 · Cited by 24
A mechanical characterization of polymer scaffolds and films at the macroscale and nanoscale
Boffito, M., Bernardi, E., Sartori, S., Ciardelli, G., & Sassi, M. P. (2014) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35147 · Cited by 25
Sustained-release of naproxen sodium from electrospun-aligned PLLA-PCL scaffolds
Lui, Y. S., Lewis, M. P., & Loo, S. C. J. (2015) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.2000 · Cited by 23
“sue regeneration rates, and its degraded by-products must be safely eliminated through natural metabolic pathways (Gunatillake and Adhikari, 2003; Rezwan et al., 2006; Salgado et al., 2004; Vert et al., 1992).”
BackgroundIn vitro bioactivity and dissolution of Ca2(SiO3)(OH)2 and β-Ca2SiO4 fibers
Gou, Z., Chang, J., Gao, J., & Wang, Z. (2004) · Journal of the European Ceramic Society · doi:10.1016/j.jeurceramsoc.2003.11.023 · Cited by 24
Jonnalagadda, J. B., Rivero, I. V., & Dertien, J. S. (2015) · Journal of Biomaterials Science Polymer Edition · doi:10.1080/09205063.2015.1015864 · Cited by 23
“[8] Poly(e-caprolactone) (PCL) is a semicrystalline, biocompatible, and biodegradable synthetic polymer used in various soft tissue engineering applications.[12,13] Threedimensional PCL scaffolds have been used in articular cartilage tissue engineering that demonstrated adhesion of chondrocytes.”
BackgroundChoy, D. K. S., Nga, V. D. W., Lim, J., Lu, J., Chou, N., Yeo, T. T., & Teoh, S. (2013) · Tissue Engineering Part A · doi:10.1089/ten.tea.2012.0733 · Cited by 25
“33,34 Based on the information above, PCL-TCP has a higher degradation rate than PCL, which could potentially lead to the formation of low molecular weight by-products (8000g/mol).”
Stem cells and liver engineering
Ordovás, L., Park, Y., & Verfaillie, C. M. (2013) · Biotechnology Advances · doi:10.1016/j.biotechadv.2013.07.002 · Cited by 23
“Synthetic polymers often lack cell recognition sites (Gunatillake and Adhikari, 2003) and are therefore not optimal.”
BackgroundPavia, F. C., Palumbo, F. S., Carrubba, V. L., Bongiovì, F., Brucato, V., Pitarresi, G. L., & Giammona, G. (2016) · Materials Science and Engineering C · doi:10.1016/j.msec.2016.05.040 · Cited by 23
“PLLA is derived from 100% renewable resources and could be eventually degraded into CO2 and H2O under natural conditions [10,11].”
BackgroundDedifferentiated Chondrocytes in Composite Microfibers As Tool for Cartilage Repair
Angelozzi, M., Penolazzi, L., Mazzitelli, S., Lambertini, E., Lolli, A., Piva, R., & Nastruzzi, C. (2017) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2017.00035 · Cited by 24
Synthesis Characterization and In Vitro Release Study of Ciprofloxacin-Loaded Chitosan Nanoparticle
Singh, K., Mishra, A., & Singh, A. (2017) · BioNanoScience · doi:10.1007/s12668-017-0470-7 · Cited by 23
Gabrielczyk, J., Duensing, T., Buchholz, S., Schwinges, A., & Jördening, H. (2018) · Applied Biochemistry and Biotechnology · doi:10.1007/s12010-018-2694-6 · Cited by 24
Potentials of Combining Nanomaterials and Stem Cell Therapy in Myocardial Repair
Yao, Y., Liao, W., Yu, R., Du, Y., Zhang, T., & Peng, Q. (2018) · Nanomedicine · doi:10.2217/nnm-2018-0013 · Cited by 24
A Combined Computational and Experimental Study on the Polymerization of ε-Caprolactone
Rosa, R. P., Ferreira, F. V., Saravia, A. P. K., Rocco, S. A., Sforça, M. L., Gouveia, R. F., & Lona, L. M. F. (2018) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.8b03288 · Cited by 25
Liu, L., Shi, Q., Chen, Q., & Li, Z. (2019) · Journal of Tissue Engineering · doi:10.1177/2041731419827167 · Cited by 23
“Then, substituting equations (6) and (7) into equation (1), we obtained the bone remodeling equation of the ith element involving the coupled two type cells regulated by mechanical stimulus”
BackgroundMethodRosendorf, J., Horáková, J., Klíčová, M., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-58113-4 · Cited by 23
Tamjid, E., Bohlouli, M., Mohammadi, S., Alipour, H., & Nikkhah, M. (2020) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.36914 · Cited by 26
Shrivats, A. R., Alvarez, P., Schutte, L., & Hollinger, J. O. (2013) · Elsevier eBooks · doi:10.1016/b978-0-12-398358-9.00055-0 · Cited by 44
Tosoratti, E., Fisch, P., Taylor, S., Laurent‐Applegate, L. A., & Zenobi‐Wong, M. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202101094 · Cited by 26
Dobrzański, L. A., Pawlyta, M., & Hudecki, A. (2011) · Journal of Achievements of Materials and Manufacturing Engineering · Cited by 23
Solvent−Solute Interactions in Hydrofluoroalkane Propellants
Peguin, R. P. S., & da Rocha, S. R. P. (2008) · The Journal of Physical Chemistry B · doi:10.1021/jp710717s · Cited by 23
Gravel, M., Vago, R., & Tabrizian, M. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.589 · Cited by 24
Carcaboso, A. M., Chiappetta, D. A., Höcht, C., Blake, M. G., Boccia, M. M., Baratti, C. M., & Sosnik, A. (2008) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2008.05.031 · Cited by 23
“This finding was in full agreement with the profuse bibliography supporting the biocompatibility of PCL in contact with different tissues and organs [23,42].”
ResultSurface Modification of Polymeric Biomaterials
Güney, A., Kara, F., Ozgen, O., Aksoy, E. A., Hasırcı, V., & Hasırcı, N. (2013) · Wiley eBooks · doi:10.1002/9783527649600.ch5 · Cited by 25
Spanu, C., Locatelli, E., Sambri, L., Franchini, M. C., & Maturi, M. (2024) · ACS Applied Polymer Materials · doi:10.1021/acsapm.3c03159 · Cited by 23
Reticular framework materials as versatile platforms for controllable polymer synthesis
Xing, Z., Wang, S., & Sun, Q. (2025) · Chemical Society Reviews · doi:10.1039/d5cs00749f · Cited by 26
Synthetic polymers for skin biomaterials
Kohli, N., Sharma, V., Brown, S. J., & García‐Gareta, E. (2019) · Elsevier eBooks · doi:10.1016/b978-0-08-102546-8.00005-4 · Cited by 37
Biomedical Applications of Additive Manufacturing
Dhavalikar, P., Lan, Z., Kar, R., Salhadar, K., Gaharwar, A. K., & Cosgriff‐Hernandez, E. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-816137-1.00040-4 · Cited by 33
Kim, D., Gwon, Y., Park, S., Kim, W., Kim, W., Yun, K., & Kim, J. (2021) · Biotechnology and Bioengineering · doi:10.1002/bit.27702 · Cited by 24
“In addition, PCL is a common material used to manufacture US Food and Drug Administration (FDA)‐ approved devices and is also relatively inexpensive (Gunatillake, 2003; D. Kim et al., 2020; Middleton & Tipton, 2000).”
MethodControlling Topography and Crystallinity of Melt Electrowritten Poly(ɛ-Caprolactone) Fibers
Blum, C., Weichhold, J., Hochleitner, G., Stepanenko, V., Würthner, F., Gröll, J., & Jüngst, T. (2021) · 3D Printing and Additive Manufacturing · doi:10.1089/3dp.2020.0290 · Cited by 22
“15 This polymer shows excellent printing behavior and has a melting temperature of 59 (cid:2) C to 64 (cid:2) C. 16 17–19 However, also submicrometer PCL fibers were achieved.”
Intranasal Administration as a Route to Deliver Drugs to the Brain (Review)
Porfiryeva, N. N., Семина, И. И., Moustafine, R. I., & Khutoryanskiy, V. V. (2021) · Drug development & registration · doi:10.33380/2305-2066-2021-10-4-117-127 · Cited by 25
Silk fibroin-based biomaterials for disc tissue engineering
Lin, M., Hu, Y., An, H., Guo, T., Gao, Y., Peng, K., Zhao, M., Zhang, X., & Zhou, H. (2022) · Biomaterials Science · doi:10.1039/d2bm01343f · Cited by 22
Natural and Synthetic Polymeric Scaffolds
Yoon, D. M., & Fisher, J. P. (2009) · Springer eBooks · doi:10.1007/978-0-387-84872-3_15 · Cited by 36
Mena, M., Chanfreau, S., Gimeno, M., & Bárzana, E. (2010) · Bioprocess and Biosystems Engineering · doi:10.1007/s00449-010-0435-5 · Cited by 24
“ROP allows for controlled molecular architectures and it is also the preferred method towards high molecular weight materials [2, 4].”
BackgroundMethodInfluentialPerivascular sirolimus-delivery system
Filová, E., Pařízek, M., Olšovská, J., et al. (2010) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2010.11.005 · Cited by 22
Niaounakis, M. (2013) · Elsevier eBooks · doi:10.1016/b978-1-4557-3145-9.00001-4 · Cited by 35
Wei, C.-K., & Ding, S. (2016) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2016.05.019 · Cited by 22
Recovery of cis,cis-muconic acid from organic phase after reactive extraction
Gorden, J., Zeiner, T., Sadowski, G., & Brandenbusch, C. (2016) · Separation and Purification Technology · doi:10.1016/j.seppur.2016.05.032 · Cited by 23
Tissue‐engineering approaches in pancreatic islet transplantation
Pérez‐Basterrechea, M., Esteban, M. M., Vega, J. A., & Obaya, Á. J. (2018) · Biotechnology and Bioengineering · doi:10.1002/bit.26821 · Cited by 22
Barua, E., Deoghare, A. B., Chatterjee, S., & Mate, V. R. (2019) · Arabian Journal for Science and Engineering · doi:10.1007/s13369-019-03877-9 · Cited by 25
Khan, M. A., Hussain, Z., Liaqat, U., Liaqat, M. A., & Zahoor, M. (2020) · Nanomaterials · doi:10.3390/nano10091778 · Cited by 22
Polymer-Based Biodegradable Drug Delivery Systems in Pain Management
Malyan, M. A., Becchi, C., Nikkola, L., Viitanen, P., Boncinelli, S., Chiellini, E., & Ashammakhi, N. A. (2006) · Journal of Craniofacial Surgery · doi:10.1097/00001665-200603000-00018 · Cited by 22
A biodegradable vascularizing membrane: A feasibility study
Kaushiva, A., Turzhitsky, V. M., Backman, V., & Ameer, G. A. (2007) · Acta Biomaterialia · doi:10.1016/j.actbio.2007.03.003 · Cited by 22
Rouholamin, D., Smith, P. J., & Ghassemieh, E. (2013) · Journal of Materials Science · doi:10.1007/s10853-012-7109-4 · Cited by 22
Patel, H. N., Garcia, R., Schindler, C., Dean, D. R., Pogwizd, S. M., Singh, R., Vohra, Y. K., & Thomas, V. (2014) · Polymer International · doi:10.1002/pi.4834 · Cited by 22
Scaffolds for Drug Delivery in Tissue Engineering
Gaikwad, V. V., Patil, A. B., & Gaikwad, M. (2008) · International Journal of Pharmaceutical Sciences and Nanotechnology · doi:10.37285/ijpsn.2008.1.2.1 · Cited by 22
Biomedical Applications of Polyhydroxyalkanoates
Lizarraga‐Valderrama, L. R., Panchal, B., Thomas, C., Boccaccini, A. R., & Roy, I. (2016) · Wiley eBooks · doi:10.1002/9781119126218.ch20 · Cited by 30
Zavradashvili, N., Puiggalí, J., & Katsarava, R. D. (2020) · Current Pharmaceutical Design · doi:10.2174/1381612826666200203122110 · Cited by 30
Matera, D. L., Lee, A. T., Hiraki, H. L., & Baker, B. M. (2021) · Cellular and Molecular Bioengineering · doi:10.1007/s12195-021-00698-5 · Cited by 26
Covalently Loaded Naloxone Nanoparticles as a Long-Acting Medical Countermeasure to Opioid Poisoning
Kassick, A. J., Wu, M. M., Luengas, D., Ebqa’ai, M., Nirmani, L. P. T., Tomycz, N. D., Nelson, T. L., Pravetoni, M., Raleigh, M. D., & Averick, S. E. (2021) · ACS Pharmacology & Translational Science · doi:10.1021/acsptsci.1c00168 · Cited by 23
Ghosal, K., Pal, S., Ghosh, D., Jana, K., & Sarkar, K. (2022) · Biomaterials Advances · doi:10.1016/j.bioadv.2022.212961 · Cited by 21
Particle carriers for controlled release of peptides
Jiang, E. Y., Desroches, S. T., & Mikos, A. G. (2023) · Journal of Controlled Release · doi:10.1016/j.jconrel.2023.03.050 · Cited by 24
Human Mesenchymal Stem Cells and Innovative Scaffolds for Bone Tissue Engineering Applications
Mazzoni, E., Iaquinta, M. R., Mosaico, M., Pace, R. D., D’Agostino, A., Tognon, M. G., & Martini, F. (2023) · Tissue Engineering Part B Reviews · doi:10.1089/ten.teb.2022.0217 · Cited by 23
“61 The most important synthetic polymers include poly ( e - caprolactone) (PCL), which was approved by the Food and Drug Administration (FDA) since it is multiform and highly biocompatible, 62 polylactic acid (PLA), polyglycolide (PGA), and the copolymer of poly-(DL-lactic-co-glycolic-acid) (PLGA).”
Superior Tissue Evolution in Slow-Degrading Scaffolds for Valvular Tissue Engineering
Brugmans, M. C. P., Soekhradj‐Soechit, R. S., van Geemen, D., Cox, M. A. J., Bouten, C. V. C., Baaijens, F. F., & Driessen‐Mol, A. (2015) · Tissue Engineering Part A · doi:10.1089/ten.tea.2015.0203 · Cited by 31
“It appeared that the site of implantation, presence of enzymes, molecular weight of the material, and scaffold porosity all affect absorption rates in vivo.(11) Reported complete absorption times of PGA vary from 1.”
Polymers for medicobiological use
Штильман, М. И. (2010) · Polymer Science Series A · doi:10.1134/s0965545x10090038 · Cited by 25
Thermal, dynamic mechanical, and dielectric analyses of some polyurethane biocomposites
Macocinschi, D., Filip, D., Vlad, S., Cristea, M., Musteata, V., & Ibanescu, S. (2012) · Journal of Biomaterials Applications · doi:10.1177/0885328210394468 · Cited by 21
Organ-Specific Tubular and Collagen-Based Composite Scaffolds
Koens, M. J. W., Geutjes, P. J., Faraj, K. A., Hilborn, J. G., Daamen, W. F., & Kuppevelt, T. H. V. (2010) · Tissue Engineering Part C Methods · doi:10.1089/ten.tec.2010.0269 · Cited by 21
Improving the Cell Distribution in Collagen-Coated Poly-Caprolactone Knittings
Sun, W.-L., Tiemessen, D. M., Sloff, M., Lammers, R. J. M., de Mulder, E. L. W., Hilborn, J. G., Gupta, B., Feitz, W., Daamen, W. F., Kuppevelt, T. H. V., et al. (2012) · Tissue Engineering Part C Methods · doi:10.1089/ten.tec.2011.0593 · Cited by 22
“20 Incorporation of supportive materials other than PCL—for instance, copolymers of lactic acid, glycolic acid, or trimethylene carbonate by which the degradation time can be tailored 19,21–23 —should greatly enhance the implementation possibilities for soft tissues.”
Biodegradable HEMA ‐based hydrogels with enhanced mechanical properties
Moghadam, M. N., & Pioletti, D. P. (2015) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.33469 · Cited by 21
Natarajan, J., Madras, G., & Chatterjee, K. (2016) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2016.02.039 · Cited by 21
Polymers for oral and dental tissue engineering
Salehi‐Nik, N., Rad, M. R., Nazeman, P., & Khojasteh, A. (2017) · Elsevier eBooks · doi:10.1016/b978-0-08-100961-1.00003-7 · Cited by 27
Zhang, Q., Fang, J., Liu, W., Zhao, Y., Huang, T., Cui, J., Yang, Y., & Zhou, Z. (2018) · International Journal of Polymer Analysis and Characterization · doi:10.1080/1023666x.2018.1478618 · Cited by 21
A 3D‐printed polycaprolactone/β‐tricalcium phosphate mandibular prosthesis: A pilot animal study
Park, J. H., Jung, S. Y., Lee, C.-K., Ban, M. J., Lee, S. J., Kim, H. Y., Oh, H. J., Kim, B. K., Park, H. S., Jang, S., et al. (2019) · The Laryngoscope · doi:10.1002/lary.27908 · Cited by 21
Salles, T. H. C., Volpe‐Zanutto, F., Sousa, I. M. D. O., Machado, D., Zanatta, A. C., Vilegas, W., Lancellotti, M., Foglio, M. A., & d’Ávila, M. A. (2020) · Biomedical Materials · doi:10.1088/1748-605x/ab9bb1 · Cited by 21
Metadata
- Authors
- CSIRO Molecular Science, B. 1., & Gunatillake, P.
- Corresponding author
- CSIRO Molecular Science, Bag 10, Clayton South MDC, Vic 3169, Australia
- Venue
- European Cells and Materials
- Publisher
- Forum Multimedia Publishing LLC
- Published
- 2003-10-01
- Volume
- 5
- Pages
- 1-16
- ISSN
- 1473-2262 (ISSN-L)
- OpenAlex
- W2106035984
- Cited by
- 1,765
- References
- 97
- Citations by year
- 2026: 43 · 2025: 61 · 2024: 59 · 2023: 80 · 2022: 90 · 2021: 112 · 2020: 102 · 2019: 115 · 2018: 105 · 2017: 128 · 2016: 110 · 2015: 106 · 2014: 110 · 2013: 91 · 2012: 86
- FWCI
- 1.32
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- European Cells and Materials (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Topics
- Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Health Sciences › Medicine › Surgery › Surgical Sutures and Adhesives
- Keywords
- tissue engineering, polyesters, polyglycolic acid, polylactic acid, polyanhydrides, polyphosphazenes, polyurethane, poly(propylene fumarate), injectable polymers, orthopedic tissue engineering, biodegradation, biocompatibility, degradation products
- MeSH terms
- Biocompatible Materials, Models, Chemical, Polymers, Tissue Engineering
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.