The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Fully Automated Closed-Loop Insulin Delivery Versus Semiautomated Hybrid Control in Pediatric Patients With Type 1 Diabetes Using an Artificial Pancreas
Abstract
OBJECTIVE—The most promising β-cell replacement therapy for children with type 1 diabetes is a closed-loop artificial pancreas incorporating continuous glucose sensors and insulin pumps. The Medtronic MiniMed external physiological insulin delivery (ePID) system combines an external pump and sensor with a variable insulin infusion rate algorithm designed to emulate the physiological characteristics of the β-cell. However, delays in insulin absorption associated with the subcutaneous route of delivery inevitably lead to large postprandial glucose excursions. RESEARCH DESIGN AND METHODS—We studied the feasibility of the Medtronic ePID system in youth with type 1 diabetes and hypothesized that small manual premeal “priming” boluses would reduce postprandial excursions during closed-loop control. Seventeen adolescents (aged 15.9 ± 1.6 years; A1C 7.1 ± 0.8%) underwent 34 h of closed-loop control; 8 with full closed-loop (FCL) control and 9 with hybrid closed-loop (HCL) control (premeal priming bolus). RESULTS—Mean glucose levels were 135 ± 45 mg/dl in the HCL group versus 141 ± 55 mg/dl in the FCL group (P = 0.09); daytime glucose levels averaged 149 ± 47 mg/dl in the HCL group versus 159 ± 59 mg/dl in the FCL group (P = 0.03). Peak postprandial glucose levels averaged 194 ± 47 mg/dl in the HCL group versus 226 ± 51 mg/dl in the FCL group (P = 0.04). Nighttime control was similar in both groups (111 ± 27 vs. 112 ± 28 mg/dl). CONCLUSIONS—Closed-loop glucose control using an external sensor and insulin pump provides a means to achieve near-normal glucose concentrations in youth with type 1 diabetes during the overnight period. The addition of small manual priming bolus doses of insulin, given 15 min before meals, improves postprandial glycemic excursions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Effect of intensive therapy on the microvascular complications of type 1 diabetes mellitus
The Writing Team for the Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications Research Group (2002) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.287.19.2563 · Cited by 941
Autonomic regulation of islet hormone secretion - Implications for health and disease
Ahrén, B. (2000) · Diabetologia · doi:10.1007/s001250051322 · Cited by 909
Feasibility of Automating Insulin Delivery for the Treatment of Type 1 Diabetes
Steil, G. M., Rebrin, K., Darwin, C., Hariri, F., & Saad, M. F. (2006) · Diabetes · doi:10.2337/db06-0419 · Cited by 473
Self-citationContinuous glucose monitoring and closed‐loop systems
Hovorka, R. (2006) · Diabetic Medicine · doi:10.1111/j.1464-5491.2005.01672.x · Cited by 443
Improvement in Glycemic Excursions With a Transcutaneous, Real-Time Continuous Glucose Sensor
Garg, S., Zisser, H., Schwartz, S., Bailey, T., Kaplan, R., Ellis, S., & Jovanovic, L. (2006) · Diabetes Care · doi:10.2337/diacare.29.01.06.dc05-1686 · Cited by 433
Closed-loop insulin delivery—the path to physiological glucose control
Steil, G. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.08.011 · Cited by 313
Self-citationInsulin Resistance of Puberty: a Defect Restricted to Peripheral Glucose Metabolism*
AMIEL, S. A., CAPRIO, S., SHERWIN, R. S., PLEWE, G., HAYMOND, M. W., & TAMBORLANE, W. V. (1991) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-72-2-277 · Cited by 299
Self-citation
Cited by
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
In Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes
Kovatchev, B. P., Breton, M., Dalla Man, C., & Cobelli, C. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300106 · Cited by 760
Artificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
Outpatient Glycemic Control with a Bionic Pancreas in Type 1 Diabetes
Russell, S. J., El-Khatib, F. H., Sinha, M., Magyar, K. L., McKeon, K., Goergen, L. G., Balliro, C., Hillard, M. A., Nathan, D. M., & Damiano, E. R. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1314474 · Cited by 602
Garg, S. K., Weinzimer, S. A., Tamborlane, W. V., Buckingham, B. A., Bode, B. W., Bailey, T. S., Brazg, R. L., Ilany, J., Slover, R. H., Anderson, S. M., et al. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0421 · Cited by 585
Self-citationDiabetes: Models, Signals, and Control
Cobelli, C., Dalla Man, C., Sparacino, G., Magni, L., De Nicolao, G., & Kovatchev, B. P. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2036073 · Cited by 511
Cappon, G., Vettoretti, M., Sparacino, G., & Facchinetti, A. (2019) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2019.0121 · Cited by 477
Hovorka, R., Allen, J. M., Elleri, D., Chassin, L. J., Harris, J., Xing, D., Kollman, C., Hovorka, T., Larsen, A. M. F., Nodale, M., et al. (2010) · The Lancet · doi:10.1016/s0140-6736(09)61998-x · Cited by 450
A Bihormonal Closed-Loop Artificial Pancreas for Type 1 Diabetes
El-Khatib, F. H., Russell, S. J., Nathan, D. M., Sutherlin, R. G., & Damiano, E. R. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3000619 · Cited by 403
Closed-loop insulin delivery from bench to clinical practice
Hovorka, R. (2011) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2011.32 · Cited by 342
Specification-Based Monitoring of Cyber-Physical Systems: A Survey on Theory, Tools and Applications
Bartocci, E., Deshmukh, J., Donzé, A., Fainekos, G., Maler, O., Ničković, D., & Sankaranarayanan, S. (2018) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-75632-5_5 · Cited by 316
Fully Integrated Artificial Pancreas in Type 1 Diabetes
Breton, M., Farret, A., Bruttomesso, D., Anderson, S., Magni, L., Patek, S., Dalla Man, C., Place, J., Demartini, S., Del Favero, S., et al. (2012) · Diabetes · doi:10.2337/db11-1445 · Cited by 315
New closed-loop insulin systems
Boughton, C. K., & Hovorka, R. (2021) · Diabetologia · doi:10.1007/s00125-021-05391-w · Cited by 270
Perioperative Glycemic Control: An Evidence-based Review
Lipshutz, A. K. M., Gropper, M. A., Warner, D. S., & Warner, M. A. (2009) · Anesthesiology · doi:10.1097/aln.0b013e3181948a80 · Cited by 259
Assessing Sensor Accuracy for Non-Adjunct Use of Continuous Glucose Monitoring
Kovatchev, B. P., Patek, S. D., Ortiz, E. A., & Breton, M. D. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0272 · Cited by 234
Coming of age: the artificial pancreas for type 1 diabetes
Thabit, H., & Hovorka, R. (2016) · Diabetologia · doi:10.1007/s00125-016-4022-4 · Cited by 223
Kovatchev, B., Cobelli, C., Renard, E., Anderson, S., Breton, M., Patek, S., Clarke, W., Bruttomesso, D., Maran, A., Costa, S., et al. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400611 · Cited by 200
ISPAD Clinical Practice Consensus Guidelines 2018: diabetes technologies
Sherr, J. L., Tauschmann, M., Battelino, T., de Bock, M., Forlenza, G., Roman, R., Hood, K. K., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12731 · Cited by 197
Clarke, W. L., Anderson, S., Breton, M., Patek, S., Kashmer, L., & Kovatchev, B. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300506 · Cited by 185
Breton, M. D., Cherñavvsky, D. R., Forlenza, G. P., DeBoer, M. D., Robic, J., Wadwa, R. P., Messer, L. H., Kovatchev, B. P., & Maahs, D. M. (2017) · Diabetes Care · doi:10.2337/dc17-0883 · Cited by 179
ISPAD Clinical Practice Consensus Guidelines 2022: Diabetes technologies: Insulin delivery
Sherr, J. L., Schoelwer, M., Dos Santos, T. J., Reddy, L., Biester, T., Galderisi, A., van Dyk, J. C., Hilliard, M. E., Berget, C., & DiMeglio, L. A. (2022) · Pediatric Diabetes · doi:10.1111/pedi.13421 · Cited by 152
Kovatchev, B., Cheng, P., Anderson, S. M., Pinsker, J. E., Boscari, F., Buckingham, B. A., Doyle, F. J., Hood, K. K., Brown, S. A., Breton, M. D., et al. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0333 · Cited by 141
Sherr, J. L., Heinemann, L., Fleming, G. A., Bergenstal, R. M., Bruttomesso, D., Hanaire, H., Holl, R. W., Petrie, J. R., Peters, A. L., & Evans, M. (2022) · Diabetes Care · doi:10.2337/dci22-0018 · Cited by 136
Sherr, J. L., Cengiz, E., Palerm, C. C., Clark, B., Kurtz, N., Roy, A., Carria, L., Cantwell, M., Tamborlane, W. V., & Weinzimer, S. A. (2013) · Diabetes Care · doi:10.2337/dc13-0010 · Cited by 125
Self-citationGingras, V., Taleb, N., Roy‐Fleming, A., Legault, L., & Rabasa‐Lhoret, R. (2018) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.13052 · Cited by 113
Circadian Variability of Insulin Sensitivity: Physiological Input for In Silico Artificial Pancreas
Visentin, R., Dalla Man, C., Kudva, Y. C., Basu, A., & Cobelli, C. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0192 · Cited by 113
The Artificial Pancreas in 2016: A Digital Treatment Ecosystem for Diabetes
Kovatchev, B., Tamborlane, W. V., Cefalu, W. T., & Cobelli, C. (2016) · Diabetes Care · doi:10.2337/dc16-0824 · Cited by 95
Self-citationA Century of Diabetes Technology: Signals, Models, and Artificial Pancreas Control
Kovatchev, B. (2019) · Trends in Endocrinology & Metabolism · doi:10.1016/j.tem.2019.04.008 · Cited by 80
An Integrated Multivariable Artificial Pancreas Control System
Turksoy, K., Quinn, L. T., Littlejohn, E., & Cinar, A. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814524862 · Cited by 77
The Peripheral Peril: Injected Insulin Induces Insulin Insensitivity in Type 1 Diabetes
Gregory, J. M., Cherrington, A. D., & Moore, D. J. (2020) · Diabetes · doi:10.2337/dbi19-0026 · Cited by 76
Huyett, L. M., Ly, T. T., Forlenza, G. P., Reuschel-DiVirgilio, S., Messer, L. H., Wadwa, R. P., Gondhalekar, R., Doyle, F. J., Pinsker, J. E., Maahs, D. M., et al. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0399 · Cited by 64
Garcia-Tirado, J., Diaz, J. L., Esquivel-Zuniga, R., Koravi, C. L. K., Corbett, J. P., Dawson, M., Wakeman, C., Barnett, C. L., Oliveri, M. C., Myers, H., et al. (2021) · Diabetes Care · doi:10.2337/dc21-0932 · Cited by 52
Psychosocial impact of the bionic pancreas during summer camp
Weissberg-Benchell, J., Hessler, D., Polonsky, W. H., & Fisher, L. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816640289 · Cited by 47
Evolution of Devices in Diabetes Management
Penfornis, A., Personeni, E., & Borot, S. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0058 · Cited by 49
Advancing Our Understanding of the Glucose System via Modeling: A Perspective
Cobelli, C., Dalla Man, C., Pedersen, M. G., Bertoldo, A., & Toffolo, G. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2310514 · Cited by 46
Youssef, J. E., Castle, J. R., Branigan, D. L., Massoud, R. G., Breen, M. E., Jacobs, P. G., Bequette, B. W., & Ward, W. K. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500602 · Cited by 42
Perspectives on low-density-lipoprotein cholesterol goal achievement
Catapano, A. L. (2009) · Current Medical Research and Opinion · doi:10.1185/03007990802631438 · Cited by 40
Sherr, J. L., Palau Collazo, M., Cengiz, E., Michaud, C., Carria, L., Steffen, A. T., Weyman, K., Zgorski, M., Tichy, E., Tamborlane, W. V., et al. (2014) · Diabetes Care · doi:10.2337/dc13-1608 · Cited by 35
Self-citationReal-Time Detection of Infusion Site Failures in a Closed-Loop Artificial Pancreas
Howsmon, D. P., Baysal, N., Buckingham, B. A., Forlenza, G. P., Ly, T. T., Maahs, D. M., Marcal, T., Towers, L., Mauritzen, E., Deshpande, S., et al. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818755173 · Cited by 32
Effect of Afrezza on Glucose Dynamics During HCL Treatment
Galderisi, A., Cohen, N., Calhoun, P., Kraemer, K., Breton, M., Weinzimer, S., & Cengiz, E. (2020) · Diabetes Care · doi:10.2337/dc20-0091 · Cited by 32
Self-citationPramlintide but Not Liraglutide Suppresses Meal-Stimulated Glucagon Responses in Type 1 Diabetes
Galderisi, A., Sherr, J., VanName, M., Carria, L., Zgorski, M., Tichy, E., Weyman, K., Cengiz, E., Weinzimer, S., & Tamborlane, W. (2018) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2017-02265 · Cited by 25
Self-citationHybrid Closed-loop to Manage Gastroparesis in People With Type 1 Diabetes: a Case Series
Daly, A., Hartnell, S., Boughton, C. K., & Evans, M. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211035447 · Cited by 23
Pharmacological Properties of Faster-Acting Insulin Aspart
Biester, T., Kordonouri, O., & Danne, T. (2017) · Current Diabetes Reports · doi:10.1007/s11892-017-0931-y · Cited by 23
Metadata
- Authors
- Weinzimer, S. A., Steil, G. M., Swan, K. L., Dziura, J., Kurtz, N., & Tamborlane, W. V.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2008-05-01
- Volume
- 31
- Issue
- 5
- Pages
- 934-939
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2144785271
- Cited by
- 567
- References
- 22
- FWCI
- 28.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.