Ultra-High-Field MR Neuroimaging
Open accessThe DOI matches its Crossref record; 89 of the 89 references it cites were found in a registry or an index.
Abstract
At ultra-high magnetic fields, such as 7T, MR imaging can noninvasively visualize the brain in unprecedented detail and through enhanced contrast mechanisms. The increased SNR and enhanced contrast available at 7T enable higher resolution anatomic and vascular imaging. Greater spectral separation improves detection and characterization of metabolites in spectroscopic imaging. Enhanced blood oxygen level-dependent contrast affords higher resolution functional MR imaging. Ultra-high-field MR imaging also facilitates imaging of nonproton nuclei such as sodium and phosphorus. These improved imaging methods may be applied to detect subtle anatomic, functional, and metabolic abnormalities associated with a wide range of neurologic disorders, including epilepsy, brain tumors, multiple sclerosis, Alzheimer disease, and psychiatric conditions. At 7T, however, physical and hardware limitations cause conventional MR imaging pulse sequences to generate artifacts, requiring specialized pulse sequences and new hardware solutions to maximize the high-field gain in signal and contrast. Practical considerations for ultra-high-field MR imaging include cost, siting, and patient experience.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Relaxation Processes in a System of Two Spins
Solomon, I. (1955) · Physical Review · doi:10.1103/physrev.99.559 · Cited by 3,278
American Journal of Neuroradiology
(2020) · American Journal of Neuroradiology · doi:10.3174/ajnr · Cited by 2,453
Neurocircuitry of Mood Disorders
Price, J. L., & Drevets, W. C. (2010) · Neuropsychopharmacology · doi:10.1038/npp.2009.104 · Cited by 1,606
Neuroimaging studies of mood disorders
Drevets, W. C. (2000) · Biological Psychiatry · doi:10.1016/s0006-3223(00)01020-9 · Cited by 1,313
Drevets, W. C. (2001) · Current Opinion in Neurobiology · doi:10.1016/s0959-4388(00)00203-8 · Cited by 1,146 · cited 1×
“The etiology of mood and anxiety disorders such as major depressive disorder remains poorly understood.(59) Study results have been divergent, with no clear consensus on proper neuroimaging markers for these conditions.”
BackgroundSusceptibility-Weighted Imaging: Technical Aspects and Clinical Applications, Part 1
Haacke, E. M., Mittal, S., Wu, Z., Neelavalli, J., & Cheng, Y.-C. N. (2009) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1400 · Cited by 1,113 · cited 1×
“lature, microbleeds, and iron and calcium deposits through susceptibility-weighted imaging.(14) Figure 2 illustrates a MIP of an”
BackgroundThe Return of the Frequency Sweep: Designing Adiabatic Pulses for Contemporary NMR
Garwood, M., & DelaBarre, L. (2001) · Journal of Magnetic Resonance · doi:10.1006/jmre.2001.2340 · Cited by 952 · cited 1×
“Essentially, they provide the same contrast or tissue parameters, while combatting field inhomogeneity and remaining within safe RF power limits.(73,77-83)”
BackgroundA pathophysiological framework of hippocampal dysfunction in ageing and disease
Small, S. A., Schobel, S. A., Buxton, R. B., Witter, M. P., & Barnes, C. A. (2011) · Nature Reviews Neuroscience · doi:10.1038/nrn3085 · Cited by 926 · cited 2×
“One early pathologic change in Alzheimer disease is neuronal loss in specific subfields of the hippocampus.(57)”
Background7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images
Vaughan, J. T., Garwood, M., Collins, C. M., Liu, W., DelaBarre, L., Adriany, G., Andersen, P., Merkle, H., Goebel, R., Smith, M. B., et al. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1156 · Cited by 890 · cited 1×
“As the B0 field increases to 7T, the RF operating wavelength becomes comparable with the diameter of the human head, resulting in a severe reduction of B1 strength in the brain periphery compared with the isocenter.(70) This ultimately leads to signal drop-out and unexpected changes in contrast.”
BackgroundMcKinnon, M. C., Yucel, K., Nazarov, A., & MacQueen, G. M. (2009) · Journal of Psychiatry and Neuroscience · doi:10.1139/jpn.0905 · Cited by 742
Magnetic Resonance Imaging of the Brain and Spine
HEALTH AND PUBLIC POLICY COMMITTEE* (1988) · Annals of Internal Medicine · doi:10.7326/0003-4819-108-3-474 · Cited by 725
Katscher, U., Börnert, P., Leussler, C., & van den Brink, J. S. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10353 · Cited by 719
Parallel excitation with an array of transmit coils
Zhu, Y. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20011 · Cited by 675
Cotter, D. (2002) · Cerebral Cortex · doi:10.1093/cercor/12.4.386 · Cited by 634
The Human Hippocampus: Functional Anatomy, Vascularization and Serial Sections with MRI
Duvernoy, H. M., Cattin, F., & Risold, P.-Y. (2013) · Springer eBooks · doi:10.1007/978-3-642-33603-4 · Cited by 561
B1 mapping by Bloch‐Siegert shift
Sacolick, L. I., Wiesinger, F., Hancu, I., & Vogel, M. W. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22357 · Cited by 529
Tannús, A., & Garwood, M. (1997) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199712)10:8<423::aid-nbm488>3.0.co;2-x · Cited by 465
Liao, Y., Huang, X., Wu, Q., Yang, C., Kuang, W., Du, M., Lui, S., Yue, Q., Chan, R. C. K., Kemp, G. J., et al. (2013) · Journal of Psychiatry and Neuroscience · doi:10.1503/jpn.110180 · Cited by 461
Uludağ, K., Müller-Bierl, B., & Uğurbil, K. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.05.051 · Cited by 450
Ultra-fast MRI of the human brain with simultaneous multi-slice imaging
Feinberg, D. A., & Setsompop, K. (2013) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2013.02.002 · Cited by 433 · cited 1×
“Unfortunately, for such an acquisition, total scanning time is impractically long (75 minutes), so new approaches, such as multiband excitations, are being explored to obtain these types of results within reasonable scanning times.(23,24)”
BackgroundAutomated segmentation of hippocampal subfields from ultra‐high resolution in vivo MRI
Van Leemput, K., Bakkour, A., Benner, T., Wiggins, G., Wald, L. L., Augustinack, J., Dickerson, B. C., Golland, P., & Fischl, B. (2009) · Hippocampus · doi:10.1002/hipo.20615 · Cited by 405
Spatial domain method for the design of RF pulses in multicoil parallel excitation
Grissom, W. A., Yip, C., Zhang, Z., Stenger, V. A., Fessler, J. A., & Noll, D. C. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20978 · Cited by 370
Duong, T. Q., Yacoub, E., Adriany, G., Hu, X., Uǧurbil, K., & Kim, S. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10472 · Cited by 360 · cited 1×
“BOLD signal that arises from smaller blood vessels also scales with field strength, so the BOLD signal has better spatial correlation to oxygen extraction and is more tightly coupled to the underlying neuronal activity.(16,17)”
BackgroundImproving diffusion MRI using simultaneous multi-slice echo planar imaging
Setsompop, K., Cohen-Adad, J., Gagoski, B. A., Raij, T., Yendiki, A., Keil, B., Wedeen, V. J., & Wald, L. L. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.033 · Cited by 355 · cited 1×
“Unfortunately, for such an acquisition, total scanning time is impractically long (75 minutes), so new approaches, such as multiband excitations, are being explored to obtain these types of results within reasonable scanning times.(23,24)”
BackgroundMiguel-Hidalgo, J. J., Baucom, C., Dilley, G., Overholser, J. C., Meltzer, H. Y., Stockmeier, C. A., & Rajkowska, G. (2000) · Biological Psychiatry · doi:10.1016/s0006-3223(00)00999-9 · Cited by 336
Tissue Sodium Concentration in Human Brain Tumors as Measured with 23 Na MR Imaging
Ouwerkerk, R., Bleich, K. B., GILLEN, J. S., Pomper, M. G., & Bottomley, P. A. (2003) · Radiology · doi:10.1148/radiol.2272020483 · Cited by 331
Duvernoy’s Atlas of the Human Brain Stem and Cerebellum
Naidich, T. P., Duvernoy, H. M., Delman, B. N., Sorensen, A. G., Kollias, S. S., & Haacke, E. M. (2009) · Springer eBooks · doi:10.1007/978-3-211-73971-6 · Cited by 311
Self-citationSpin‐echo fMRI in humans using high spatial resolutions and high magnetic fields
Yacoub, E., Duong, T. Q., Van De Moortele, P., Lindquist, M., Adriany, G., Kim, S., Uğurbil, K., & Hu, X. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10433 · Cited by 308 · cited 1×
“BOLD signal that arises from smaller blood vessels also scales with field strength, so the BOLD signal has better spatial correlation to oxygen extraction and is more tightly coupled to the underlying neuronal activity.(16,17)”
BackgroundMagnetic Resonance Imaging of Hippocampal Subfields in Posttraumatic Stress Disorder
Wang, Z., Neylan, T. C., Mueller, S. G., Lenoci, M., Truran, D., Marmar, C. R., Weiner, M. W., & Schuff, N. (2010) · Archives of General Psychiatry · doi:10.1001/archgenpsychiatry.2009.205 · Cited by 300 · cited 1×
“Study results have been divergent, with no clear consensus on proper neuroimaging markers for these conditions.(2,60) However, it is known that the medial prefrontal cortex and temporolimbic structures, including the hippocampus and amygdala, are critical nodes in major depression.”
ResultSodium MRI using a density‐adapted 3D radial acquisition technique
Nagel, A. M., Laun, F. B., Weber, M., Matthies, C., Semmler, W., & Schad, L. R. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22157 · Cited by 287 · cited 4×
“The 2 pulse se- quences used for these images are given in Nagel et al.25 Total sodium images and relaxation- weighted sodium images provide complementary data.”
BackgroundMethodInfluentialHammond, K. E., Metcalf, M., Carvajal, L., Okuda, D. T., Srinivasan, R., Vigneron, D., Nelson, S. J., & Pelletier, D. (2008) · Annals of Neurology · doi:10.1002/ana.21582 · Cited by 286 · cited 2×
“This method has also been used to detect iron-rich macrophages at the periphery of MS plaques.(53)”
MethodSi, X., Miguel-Hidalgo, J. J., O'Dwyer, G., Stockmeier, C. A., & Rajkowska, G. (2004) · Neuropsychopharmacology · doi:10.1038/sj.npp.1300525 · Cited by 268
The future of ultra-high field MRI and fMRI for study of the human brain
Duyn, J. H. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.10.065 · Cited by 261 · cited 1×
“Two major determinants of MR image quality, SNR and contrast, both increase with field strength (Table).(3,4)”
BackgroundUltrahigh field magnetic resonance imaging and spectroscopy
Uğurbil, K., Adriany, G., Andersen, P., Chen, W., Garwood, M., Gruetter, R., Henry, P.-G., Kim, S.-G., Lieu, H., Tkac, I., et al. (2003) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2003.08.027 · Cited by 252 · cited 1×
“The combination of increased SNR and increased spectral separation of metabolite peaks results in higher resolution spectroscopic images and improved spectral quantification.(5) Figure 4 shows a spectrum obtained at 7T with a constant time pointresolved spectroscopic (CT-PRESS) pulse sequence described by Mayer and Sp…”
BackgroundT2* measurements in human brain at 1.5, 3 and 7 T
Peters, A. M., Brookes, M. J., Hoogenraad, F. G., Gowland, P. A., Francis, S. T., Morris, P. G., & Bowtell, R. (2007) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2007.02.014 · Cited by 245
Cloos, M. A., Boulant, N., Luong, M., Ferrand, G., Giacomini, E., Le Bihan, D., & Amadon, A. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22978 · Cited by 225 · cited 2×
“The B1 field map for every subject may be measured by using new fast and accurate B1-mapping methods.84,85 Then, 2D tailored RF pulses may be designed to cancel the B1 variation and achieve a consistent flip angle throughout the FOV.86,87 These tailored 2D pulses require less RF power than adiabatic pulses but may hav…”
BackgroundFast‐kzthree‐dimensional tailored radiofrequency pulse for reducedB1inhomogeneity
Saekho, S., Yip, C., Noll, D. C., Boada, F. E., & Stenger, V. A. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20840 · Cited by 206 · cited 2×
“The B1 field map for every subject may be measured by using new fast and accurate B1-mapping methods.84,85 Then, 2D tailored RF pulses may be designed to cancel the B1 variation and achieve a consistent flip angle throughout the FOV.86,87 These tailored 2D pulses require less RF power than adiabatic pulses but may hav…”
BackgroundMichaeli, S., Garwood, M., Zhu, X., DelaBarre, L., Andersen, P., Adriany, G., Merkle, H., Ugurbil, K., & Chen, W. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10135 · Cited by 198
Cytoarchitecture of the human cerebral cortex: MR microscopy of excised specimens at 9.4 Tesla.
Fatterpekar, G. M., Naidich, T. P., Delman, B. N., Aguinaldo, J. G. S., Gultekin, S. H., Sherwood, C. C., Hof, P. R., Drayer, B. P., & Fayad, Z. A. (2002) · PubMed Central · Cited by 195
Self-citationHippocampal CA1 apical neuropil atrophy in mild Alzheimer disease visualized with 7-T MRI
Kerchner, G. A., Hess, C. P., Hammond-Rosenbluth, K. E., Xu, D., Rabinovici, G. D., Kelley, D. A. C., Vigneron, D. B., Nelson, S. J., & Miller, B. L. (2010) · Neurology · doi:10.1212/wnl.0b013e3181f736a1 · Cited by 193
Kollia, K., Maderwald, S., Putzki, N., Schlamann, M., Theysohn, J. M., Kraff, O., Ladd, M. E., Forsting, M., & Wanke, I. (2009) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1434 · Cited by 193 · cited 2×
“Clinical Applications of 7T in Neuroradiology High-resolution 7T imaging may now be used to improve the detection and characterization of abnormalities associated with a wide range of neurologic disorders, including epilepsy, brain tumors, multiple sclerosis, Alzheimer disease/dementia, and neuropsychiatric disorders.…”
BackgroundMethodMRI at 7 tesla and above: Demonstrated and potential capabilities
Kraff, O., Fischer, A., Nagel, A. M., Mönninghoff, C., & Ladd, M. E. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24573 · Cited by 190 · cited 1×
“Two major determinants of MR image quality, SNR and contrast, both increase with field strength (Table).(3,4)”
Background7‐T MR—from research to clinical applications?
Moser, E., Stahlberg, F., Ladd, M. E., & Trattnig, S. (2012) · NMR in Biomedicine · doi:10.1002/nbm.1794 · Cited by 187
Subfields of the hippocampal formation at 7 T MRI: In vivo volumetric assessment
Wisse, L. E. M., Gerritsen, L., Zwanenburg, J. J. M., Kuijf, H. J., Luijten, P. R., Biessels, G. J., & Geerlings, M. I. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.023 · Cited by 183 · cited 2×
“7T and 7T successfully differentiates among hippocampal subfields and should, therefore, provide a more sensitive marker for psychiatric disease than does total hippocampal volume.(12,13,64) Huang et al(65) have already conducted high-field (4.”
BackgroundMethodHuang, Y., Coupland, N. J., Lebel, R. M., Carter, R., Seres, P., Wilman, A. H., & Malykhin, N. V. (2013) · Biological Psychiatry · doi:10.1016/j.biopsych.2013.01.005 · Cited by 179
Diffusion imaging in humans at 7T using readout‐segmented EPI and GRAPPA
Heidemann, R. M., Porter, D. A., Anwander, A., Feiweier, T., Heberlein, K., Knösche, T. R., & Turner, R. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22480 · Cited by 172 · cited 1×
“acquisition times to overcome some of the SAR limitations and B0 field distortions.(22) Lower flip angle schedules have been designed to achieve contrast similar to that achieved by trains of high flip angle RF pulses like TSE and FSE sequences.”
MethodDeistung, A., Schweser, F., Wiestler, B., Abello, M., Roethke, M., Sahm, F., Wick, W., Nagel, A. M., Heiland, S., Schlemmer, H.-P., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0057924 · Cited by 166 · cited 1×
“Another MR imaging parameter, intratumoral susceptibility signals (ITSSs), correlates with tumor malignancy and may contribute to a grading system for gliomas.(49,50) Park et al(50) showed that the Spearman correlation coefficients between ITSS degree and glioma grade were 0.”
BackgroundTowards 1H-MRSI of the human brain at 7T with slice-selective adiabatic refocusing pulses
Scheenen, T. W. J., Heerschap, A., & Klomp, D. W. J. (2008) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-007-0094-y · Cited by 166
Chakeres, D. W., Kangarlu, A., Boudoulas, H., & Young, D. C. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10367 · Cited by 161 · cited 1×
“Metallic taste in the mouth has also been reported and is likely due to electrolysis of metallic chemicals in dental fillings while moving through the field.(94) All effects disappear when the person is out of the magnet.”
BackgroundIn vivo quantification of hippocampal subfields using 4.7 T fast spin echo imaging
Malykhin, N. V., Lebel, R. M., Coupland, N. J., Wilman, A. H., & Carter, R. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.09.042 · Cited by 159 · cited 1×
“7T and 7T successfully differentiates among hippocampal subfields and should, therefore, provide a more sensitive marker for psychiatric disease than does total hippocampal volume.(12,13,64) Huang et al(65) have already conducted high-field (4.”
BackgroundPark, M. J., Kim, H. S., Jahng, G., Ryu, C., Park, S. M., & Kim, S. Y. (2009) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1593 · Cited by 158 · cited 1×
“Another MR imaging parameter, intratumoral susceptibility signals (ITSSs), correlates with tumor malignancy and may contribute to a grading system for gliomas.(49,50) Park et al(50) showed that the Spearman correlation coefficients between ITSS degree and glioma grade were 0.”
BackgroundSanchez-Panchuelo, R. M., Besle, J., Beckett, A., Bowtell, R., Schluppeck, D., & Francis, S. (2012) · The Journal of Neuroscience · doi:10.1523/jneurosci.2501-12.2012 · Cited by 148 · cited 1×
“should enhance BOLD contrast, permitting higher resolution functional MR imaging.(15) Furthermore, the component of the From the Translational and Molecular Imaging Institute (P.”
MethodMadelin, G., Kline, R., Walvick, R. P., & Regatte, R. R. (2014) · Scientific Reports · doi:10.1038/srep04763 · Cited by 135 · cited 2×
“7T MR imaging has already shown differences in the cornu ammonis 1 hippocampal subfield of patients with mild Alzheimer disease compared with controls.(35) Figure 11 illustrates 7T images of the left hippocampus of age-matched healthy individuals (A) versus those with amnestic mild cognitive impairment (B) and probabl…”
BackgroundMethodBartha, R., Michaeli, S., Merkle, H., Adriany, G., Andersen, P., Chen, W., Uǧurbil, K., & Garwood, M. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10112 · Cited by 134
High‐resolution 7T MRI of the human hippocampus in vivo
Thomas, B. P., Welch, E. B., Niederhauser, B. D., Whetsell, W. O., Anderson, A. W., Gore, J. C., Avison, M. J., & Creasy, J. L. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21576 · Cited by 130
Signal to noise ratio and uncertainty in diffusion tensor imaging at 1.5, 3.0, and 7.0 Tesla
Polders, D. L., Leemans, A., Hendrikse, J., Donahue, M. J., Luijten, P. R., & Hoogduin, J. M. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22554 · Cited by 129 · cited 1×
“5T.(20) Figure 5 illustrates streamlines generated from diffusion-weighted data obtained on a FIG 1.”
BackgroundGe, Y., Zohrabian, V. M., & Grossman, R. I. (2008) · Archives of Neurology · doi:10.1001/archneur.65.6.812 · Cited by 125 · cited 1×
“may be assessed in vivo through highly sensitive T2* and susceptibility-weighted imaging at 7T.(55,56) SWI at ultra-high fields also”
BackgroundNagel, A. M., Bock, M., Hartmann, C. J., Gerigk, L., Neumann, J., Weber, M., Bendszus, M., Radbruch, A., Wick, W., Schlemmer, H.-P., et al. (2011) · Investigative Radiology · doi:10.1097/rli.0b013e31821ae918 · Cited by 124 · cited 4×
“The 2 pulse se- quences used for these images are given in Nagel et al.25 Total sodium images and relaxation- weighted sodium images provide complementary data.”
MethodInfluentialHippocampal Sclerosis in Temporal Lobe Epilepsy: Findings at 7 T
Henry, T. R., Marie Chupin, A., Lehéricy, S., et al. (2011) · Radiology · doi:10.1148/radiol.11101651 · Cited by 121
3 Tesla and 7 Tesla MRI of multiple sclerosis cortical lesions
Tallantyre, E. C., Morgan, P. S., Dixon, J. E., Al‐Radaideh, A., Brookes, M. J., Morris, P. G., & Evangelou, N. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22115 · Cited by 117
Using High-Resolution MR Imaging at 7T to Evaluate the Anatomy of the Midbrain Dopaminergic System
Eapen, M., Zald, D. H., Gatenby, J. C., Ding, Z., & Gore, J. C. (2010) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2355 · Cited by 117
Sodium MR Imaging of Acute and Subacute Stroke for Assessment of Tissue Viability
Thulborn, K. R., Davis, D. K., Snyder, J. V., Yonas, H., & Kassam, A. B. (2005) · Neuroimaging Clinics of North America · doi:10.1016/j.nic.2005.08.003 · Cited by 111
New directions in clinical imaging of cortical dysplasias
Madan, N., & Grant, P. E. (2009) · Epilepsia · doi:10.1111/j.1528-1167.2009.02292.x · Cited by 105
Qiao, H., Zhang, X., Zhu, X., Du, F., & Chen, W. (2006) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2006.08.002 · Cited by 104
Loss of Cell Ion Homeostasis and Cell Viability in the Brain: What Sodium MRI Can Tell Us
Boada, F. E., LaVerde, G. C., Jungreis, C. A., Nemoto, E. M., Tanase, C., & Hancu, I. (2005) · Current topics in developmental biology/Current Topics in Developmental Biology · doi:10.1016/s0070-2153(05)70004-1 · Cited by 102 · cited 1×
“Thus, the total sodium signal probes several aspects of tissue viability.(29) 7T (23)Na MR imaging using optimized pulse sequences has been performed in patients with brain tumors (14 World Health Organization [WHO] grades I–IV and 2 metastases).”
BackgroundRapid isotropic 3D‐sodium MRI of the knee joint in vivo at 7T
Wang, L., Wu, Y., Chang, G. A., Oesingmann, N., Schweitzer, M. E., Jerschow, A., & Regatte, R. R. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21881 · Cited by 89 · cited 1×
“specialized sequences that rapidly encode spatial frequency space to capture the signal.(26,30,92,93)”
BackgroundAdvanced MR methods at ultra-high field (7 Tesla) for clinical musculoskeletal applications
Trattnig, S., Zbýň, Š., Schmitt, B., Friedrich, K., Juráš, V., Szomolányi, P., & Bogner, W. (2012) · European Radiology · doi:10.1007/s00330-012-2508-0 · Cited by 79
Quantitative Sodium MR Imaging and Sodium Bioscales for the Management of Brain Tumors
Thulborn, K. R., Lu, A., Atkinson, I. C., Damen, F., & Villano, J. L. (2009) · Neuroimaging Clinics of North America · doi:10.1016/j.nic.2009.09.001 · Cited by 75
Mayer, D., & Spielman, D. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20571 · Cited by 65 · cited 2×
“The combination of increased SNR and increased spec- tral separation of metabolite peaks results in higher resolution spectroscopic images and improved spectral quantification.5 Fig- ure 4 shows a spectrum obtained at 7T with a constant time point- resolved spectroscopic (CT-PRESS) pulse sequence described by Mayer an…”
BackgroundGe, Y., Law, M., Herbert, J., & Grossman, R. I. (2005) · PubMed · Cited by 64
In Vivo35Cl MR Imaging in Humans: A Feasibility Study
Nagel, A. M., Lehmann‐Horn, F., Weber, M., Jurkat‐Rott, K., Wolf, M. B., Radbruch, A., Umathum, R., & Semmler, W. (2014) · Radiology · doi:10.1148/radiol.13131725 · Cited by 61 · cited 2×
“Early work indicates that (35)Cl imaging may reveal pathophysiologic changes associated with loss of chloride homeostasis.(27)”
BackgroundCortical phase changes in Alzheimer's disease at 7T MRI: A novel imaging marker
van Rooden, S., Versluis, M. J., Liem, M. K., Milles, J., Maier, A. B., Oleksik, A. M., Webb, A. G., van Buchem, M. A., & van der Grond, J. (2014) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2013.02.002 · Cited by 55 · cited 1×
“This study revealed increased phase shift within the cortex of patients with Alzheimer disease versus controls.(58) Therefore, relative phase shift, measured through 7T T2*-weighted imaging, may serve as a potential early imaging marker for Alzheimer disease.”
BackgroundHigh‐resolution sodium imaging of human brain at 7 T
Qian, Y., Zhao, T., Zheng, H. R., Weimer, J. M., & Boada, F. E. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23225 · Cited by 51
Ultra-High Field 7T MRI: A New Tool for Studying Alzheimer's Disease
Kerchner, G. A. (2011) · Journal of Alzheimer s Disease · doi:10.3233/jad-2011-0023 · Cited by 50 · cited 2×
“as an effective tool for revealing these changes.(9) 7T MR imaging has already shown differences in the cornu ammonis 1 hippocampal subfield of patients with mild Alzheimer disease compared with controls.”
MethodHigh‐field MRS of the human brain at short TE and TR
Boer, V. O., Siero, J. C. W., Hoogduin, H. M., van Gorp, J. S., Luijten, P. R., & Klomp, D. W. J. (2011) · NMR in Biomedicine · doi:10.1002/nbm.1660 · Cited by 49
Sodium imaging of human brain at 7 T with 15‐channel array coil
Qian, Y., Zhao, T., Wiggins, G. C., Wald, L. L., Zheng, H. R., Weimer, J. M., & Boada, F. E. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24192 · Cited by 45 · cited 1×
“specialized sequences that rapidly encode spatial frequency space to capture the signal.(26,30,92,93)”
BackgroundGrabner, G., Nöbauer, I., Elandt, K., Kronnerwetter, C., Wöehrer, A., Marosi, C., Prayer, D., Trattnig, S., & Preusser, M. (2011) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2011.08.004 · Cited by 44
Human Hippocampal Subfields in Young Adults at 7.0 T: Feasibility of Imaging
Prudent, V., Kumar, A., Liu, S., Wiggins, G. C., Malaspina, D., & Gonen, O. (2010) · Radiology · doi:10.1148/radiol.09090897 · Cited by 43 · cited 1×
“7T and 7T successfully differentiates among hippocampal subfields and should, therefore, provide a more sensitive marker for psychiatric disease than does total hippocampal volume.(12,13,64) Huang et al(65) have already conducted high-field (4.”
BackgroundAdvances in ultra-high field MRI for the clinical management of patients with brain tumors
Lupo, J., Li, Y., Hess, C. P., & Nelson, S. J. (2011) · Current Opinion in Neurology · doi:10.1097/wco.0b013e32834cd495 · Cited by 41 · cited 1×
“(1)H-MR spectroscopic imaging (MRSI) at 7T has been shown to provide a benefit for measuring metabolic markers of tumor tissue, such as choline and N-acetylaspartate, with increased spectral and spatial resolution compared with 3T.(45)”
BackgroundCox, E. F., & Gowland, P. A. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22522 · Cited by 39 · cited 1×
“from 76 to 47 ms in frontal gray matter and from 71 to 47 ms in white matter, when moving from 3T to 7T.(71)”
BackgroundSaranathan, M., Tourdias, T., Kerr, A. B., Bernstein, J. D., Kerchner, G. A., Han, M. H., & Rutt, B. K. (2014) · Investigative Radiology · doi:10.1097/rli.0000000000000041 · Cited by 31 · cited 1×
“These may also help to reduce the amount of RF energy deposited.(88)”
BackgroundDual‐echo arteriovenography imaging with 7T MRI
Bae, K. T., Park, S., Moon, C., Kim, J. H., Kaya, D., & Zhao, T. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22019 · Cited by 28 · cited 1×
“At 7T, the higher SNR and longer T1 values for tissue enhance suppression of static background signal in TOF angiography, increasing overall contrast and the detectability of smaller arteries.(18) Figure 3 shows a TOF image obtained at 7T depicting the multiple arterial branches arising from the anterior and middle ce…”
BackgroundComposite RF pulses for -insensitive volume excitation at 7Tesla
Moore, J. E., Jankiewicz, M., Zeng, H., Anderson, A. W., & Gore, J. C. (2010) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2010.04.002 · Cited by 27
Adiabatic RF pulse design for Bloch-SiegertB+ mapping
Khalighi, M. M., Rutt, B. K., & Kerr, A. B. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24507 · Cited by 27 · cited 1×
“The B1 field map for every subject may be measured by using new fast and accurate B1-mapping methods.(84,85) Then, 2D tailored RF pulses may be designed to cancel the B1 variation and achieve a consistent flip angle throughout the FOV.”
MethodAdiabatic turbo spin echo in human applications at 7 T
van Kalleveen, I. M. L., Koning, W., Boer, V. O., Luijten, P. R., Zwanenburg, J. J. M., & Klomp, D. W. J. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23264 · Cited by 24
Venocentric Lesions: An MRI Marker of MS?
Quinn, M. P., Kremenchutzky, M., & Menon, R. S. (2013) · Frontiers in Neurology · doi:10.3389/fneur.2013.00098 · Cited by 18 · cited 1×
“may be assessed in vivo through highly sensitive T2* and susceptibility-weighted imaging at 7T.(55,56) SWI at ultra-high fields also”
BackgroundQuantification of glutamate and glutamine using constant‐time point‐resolved spectroscopy at 3 T
Gu, M., Zahr, N. M., Spielman, D. M., Sullivan, E. V., Pfefferbaum, A., & Mayer, D. (2012) · NMR in Biomedicine · doi:10.1002/nbm.2831 · Cited by 17 · cited 1×
“Plotted below the in vivo data are simulated spectra of individual metabolites, as generated by the CT-PRESS acquisitions.(103) Metabolites shown are: phosphocreatine (PCr), creatine (Cr), myo-inositol (mI), scyllo-inositol (sI), N-acetylaspartate (NAA), N-acetyl aspartylglutamate (NAAG), alanine (Ala), aspartate (Asp…”
MethodUltra High Field Magnetic Resonance Imaging: A Historical Perspective
Robitaille, P.-M. L. (2007) · Springer eBooks · doi:10.1007/978-0-387-49648-1_1 · Cited by 13 · cited 2×
“present, the safe noise level is set at 99 dB(A) with the use of ear protection.(95) Systems have been tested to operate within these”
BackgroundMethodBalchandani, P., & Qiu, D. (2014) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2014.04.003 · Cited by 9
Self-citation
Cited by
Öz, G., Deelchand, D. K., Wijnen, J. P., Mlynárik, V., Xin, L., Mekle, R., Noeske, R., Scheenen, T. W. J., Tkáč, I., & the Experts' Working Group on Advanced Single Voxel H MRS (2021) · NMR in Biomedicine · doi:10.1002/nbm.4236 · Cited by 189
“field B1 + of the pulses is inhomogeneous across the brain and body at high fields, despite the use of volume RF excitation coils.(5,6) Depending on the size and location of a spectroscopic volume of interest (VOI), this inhomogeneity can cause intravoxel variation of flip angles (in large volume selections) or a bias…”
Background7T MRI in focal epilepsy with unrevealing conventional field strength imaging
De Ciantis, A., Barba, C., Tassi, L., Cosottini, M., Tosetti, M., Costagli, M., Bramerio, M., Bartolini, E., Biagi, L., Cossu, M., et al. (2016) · Epilepsia · doi:10.1111/epi.13313 · Cited by 160
Current methods and new directions in resting state fMRI
Yang, J., Gohel, S., & Vachha, B. (2020) · Clinical Imaging · doi:10.1016/j.clinimag.2020.04.004 · Cited by 110
Detcheverry, F., Senthil, S., Narayanan, S., & Badhwar, A. (2023) · NeuroImage: Clinical · doi:10.1016/j.nicl.2023.103503 · Cited by 64
“%) reproducibility studies in our review were conducted at 7T, a field strength better suited for the detection of GSH (Balchandani and Naidich, 2015; Godlewska et al., 2017), only one study assessed age-specific GSH level variations at this magnet strength.”
Background
Metadata
- Authors
- Balchandani, P., & Naidich, T. P.
- Venue
- American Journal of Neuroradiology
- Published
- 2014-12-18
- Volume
- 36
- Issue
- 7
- Pages
- 1204-1215
- ISSN
- 0195-6108 (ISSN-L)
- 1936-959X
- OpenAlex
- W2007683591
- Cited by
- 193
- References
- 89
- FWCI
- 7.46
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.