Modelling the Proton-Conductive Membrane in Practical Polymer Electrolyte Membrane Fuel Cell (PEMFC) Simulation: A Review
Open accessThe DOI matches its Crossref record; 190 of the 192 references it cites were found in a registry or an index; 26 of the 228 sources its claims cite were checked for support.
Abstract
Theoretical models used to describe the proton-conductive membrane in polymer electrolyte membrane fuel cells (PEMFCs) are reviewed, including proton conductivity, water sorption, diffusion, electroosmotic drag, swelling, gas transport, and degradation parameterization.
Overview
CoChat Summary
TL;DR
This review synthesizes 30 years of membrane-transport modelling for low-temperature PEMFC simulation, focusing on macroscopically observable charge, water, heat, gas, and degradation phenomena. It argues that coupled proton–water transport models, especially the Springer and Weber–Newman frameworks, are the dominant practical choices, but that their parameterisation is still heavily reliant on older Nafion data.
Key findings
- The review finds that a simple Ohm’s-law membrane model is only adequate under uniform hydration; most spatially resolved PEMFC simulations need coupled proton–water transport because membrane conductivity depends strongly on water content and water flux is tied to electroosmotic drag.
- It identifies the Springer and Weber–Newman models as the most widely used coupled transport approaches, with the Weber–Newman framework separating vapour-equilibrated (VE) and liquid-equilibrated (LE) conditions and allowing different transport coefficients in each regime.
- The authors report that many recent simulations still rely on 1990s parameterisation: in a sampled set of 8 PEMFC simulations published since 2019, 6 used the Springer model and 2 used the Weber–Newman model; the Springer-based works drew exclusively on four experimental studies from 1998 or earlier on Nafion 117.
- The paper notes several quantitative values from the literature, including Nafion 1100 MEW ≈ 1.100 kg mol−1, dry density ρdry ≈ 2050 kg m−3, and an experimental interfacial proton resistance of at least 8 mΩ cm2 for a directly painted Nafion-based MEA.
Methods
- Narrative review of theoretical and empirical membrane-transport models for PEMFC simulation, with emphasis on practical continuum-scale device modelling rather than atomic-scale chemistry.
- Compiles and standardizes reported equations and parameterisations, especially for Nafion 1100, across transport topics including proton conductivity, sorption isotherms, water diffusivity, electroosmotic drag, interfacial resistances, hydraulic flow, thermal effects, gas crossover, contamination, and degradation.
- Uses literature comparison and qualitative appraisal; the paper also presents a sampled review of 8 recent 2D/3D PEMFC simulation papers to illustrate dependence on legacy parameter sets.
Limitations
- Stated in the paper: the review is explicitly not comprehensive for the broader proton-conductive membrane literature, not focused on atomic-scale structure, and does not cover cold-start freezing or high-temperature PEM devices; it also excludes a detailed discussion of ionomer morphology in catalyst layers.
- Stated in the paper: detailed discussion of model validation is beyond scope, and the authors note that many current models depend on outdated material parameterisation rather than state-of-the-art membranes.
- Evident from the text: the review is heavily centered on Nafion-family/PFSA membranes, so transferability to other chemistries is only discussed cautiously and not exhaustively.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures








![Figure 9 Permeation coefficients for H2 and O2 as a function of temperature, using data summarised by Weber and Newman [65].](https://figures.cochat.ai/paper-figures/05084ed56c6c40f3a001cea2ab83cd81/modelling-the-proton-conductive-membrane-in-practical-polymer-electrolyte-figure-9.jpg)
![Figure 10 Henry’s law coefficients for H2 and O2 as a function of temperature, using data summarised by Wong and Kjeang [137].](https://figures.cochat.ai/paper-figures/1e3cab47d93c40409fa5cca1bd9434fe/modelling-the-proton-conductive-membrane-in-practical-polymer-electrolyte-figure-10.jpg)
Verification
Claims the paper makes
21 Valid · 10 Not valid · 134 Not checked · 70 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“A number of empirical sorption isotherms have been established experimentally based on measurements on Nafion 1100 [39,51,52,53,54].”
§ Modelling the Proton-Conductive Membrane in Practical Polymer Electrolyte Membrane Fuel Cell (PEMFC) Simulation: A Review > 4. Sorption of Water > 4.2. Empirical Sorption Models for Nafion 1100
What the sources say
- Partly supportedcites [39] Springer, 1991, Polymer Electrolyte Fuel Cell Model, J. Electrochem. Soc. sourceExperimental — accuracy not yet measured
The Mathematical Model section (page unavailable) reports an experimentally measured isopiestic curve and an empirical fit relating water content to water activity for Nafion 117. It supports the existence of an experimentally based sorption relationship, but does not establish that this paper presents a number of isotherms or identify the measured membrane as “Nafion 1100.” (LLM, conf=0.83)
- Could not verifycites [51] Springer, 1993, Modeling and Experimental Diagnostics in Polymer Electrolyte Fuel Cells, J. Electrochem. Soc. sourceExperimental — accuracy not yet measured
Our copy of Springer et al. (1993) is a cathode-focused modeling and diagnostics paper: the closest membrane material is the Abstract/introduction statement that earlier work 'focused on the losses in the ionomeric membrane, which we calculated for PEFC membranes of well-characterized transport properties' and the conductivity measurements on silica/recast-Nafion composites ('Calculated effects of permeability and conductivity limitations'). No passage reports or discusses empirical water sorption isotherms, and no passage mentions Nafion 1100 (searched: 'sorption isotherm Nafion 1100 water uptake', 'membrane water sorption relative humidity lambda', 'equilibrium water content versus activity isotherm'). Nothing in our copy contradicts the claim either, so the cited five references cannot be checked against this source. (LLM, conf=0.70)
- Partly supportedcites [52] Zawodzinski, 1993, Water Uptake by and Transport Through Nafion® 117 Membranes, J. Electrochem. Soc. sourceExperimental — accuracy not yet measured
The Experimental section describes measuring water sorption, and Results and Discussion presents an isopiestic sorption curve for Nafion 117 at 30°C. This supports the paper as one source of experimental sorption data, but our copy does not identify the membrane as “Nafion 1100” or establish multiple isotherms in this paper. (LLM, conf=0.82)
- Not checked — no full text of the sourcecites [53] Zawodzinski, 1993, Characterization of polymer electrolytes for fuel cell applications, Solid State Ion. source
- Not checked — no full text of the sourcecites [54] Broka, 1997, Modelling the PEM fuel cell cathode, J. Appl. Electrochem. source
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The most commonly used sorption isotherm is an empirical polynomial relation due to Springer et al. [39]:”
§ Modelling the Proton-Conductive Membrane in Practical Polymer Electrolyte Membrane Fuel Cell (PEMFC) Simulation: A Review > 4. Sorption of Water > 4.2. Empirical Sorption Models for Nafion 1100
What the sources say
- Partly supportedcites [39] Springer, 1991, Polymer Electrolyte Fuel Cell Model, J. Electrochem. Soc. sourceExperimental — accuracy not yet measured
The Mathematical Model section (page not available) gives an empirical polynomial relating membrane water content to water activity, supporting the attribution of that relation to Springer et al. Our copy does not establish that it is the most commonly used sorption isotherm. (LLM, conf=0.88)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“From a thermodynamic standpoint, the inclusion of pressure as a local variable, in addition to electrolyte potential and water content, is almost certainly an overdetermination of the system except for the liquid-equilibrated case; it has not found general support [65,78].”
§ Modelling the Proton-Conductive Membrane in Practical Polymer Electrolyte Membrane Fuel Cell (PEMFC) Simulation: A Review > 5. Coupled Proton-Water Transport
What the sources say
- Supportedcites [65] Weber, 2004, Transport in polymer-electrolyte membranes—II. Mathematical model, J. Electrochem. Soc. source
In the Mathematical Model section (page unavailable), the paper says that treating pressure as a separate driving force in a vapor-equilibrated membrane adds a variable and requires another equation or assumption; it calls common treatments nonrigorous and potentially arbitrary. It distinguishes the liquid-equilibrated case, where the chemical-potential driving force can be expressed in terms of pressure alone. (LLM, conf=0.86)
- Not checked — no full text of the sourcecites [78] Paddison, S.J., and Promislow, K.S. (2009). Coupled Proton and Water Transport in Polymer Electrolyte Membranes. Device and Materials Modeling in PEM Fuel Cells, Springer. source
hedged- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“From a thermodynamic standpoint, the inclusion of pressure as a local variable, in addition to electrolyte potential and water content, is almost certainly an overdetermination of the system except for the liquid-equilibrated case; it has not found general support [65,78].”
§ Modelling the Proton-Conductive Membrane in Practical Polymer Electrolyte Membrane Fuel Cell (PEMFC) Simulation: A Review > 5. Coupled Proton-Water Transport
What the sources say
- Partly supportedcites [65] Weber, 2004, Transport in polymer-electrolyte membranes—II. Mathematical model, J. Electrochem. Soc. sourceExperimental — accuracy not yet measured
The Mathematical Model section says that separating chemical potential into activity and pressure in a vapor-equilibrated membrane introduces another variable and requires an additional equation or assumption; it also says the common treatments are not rigorous. It distinguishes the liquid-equilibrated case, where pressure can be the driving force. It does not say that including pressure overdetermines a system specified by electrolyte potential and water content, or establish the broader claim that the approach has not found general support. Page numbers are unavailable in our copy. (LLM, conf=0.82)
- Not checked — no full text of the sourcecites [78] Paddison, S.J., and Promislow, K.S. (2009). Coupled Proton and Water Transport in Polymer Electrolyte Membranes. Device and Materials Modeling in PEM Fuel Cells, Springer. source
hedged- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“Weber and Newman have advocated the interpretation of the hydrated membrane as a system with three chemical components: water, protons, and fixed membrane structure [65].”
§ Modelling the Proton-Conductive Membrane in Practical Polymer Electrolyte Membrane Fuel Cell (PEMFC) Simulation: A Review > 5. Coupled Proton-Water Transport
What the sources say
- Supportedcites [65] Weber, 2004, Transport in polymer-electrolyte membranes—II. Mathematical model, J. Electrochem. Soc. source
The Mathematical Model section describes a concentrated-solution system composed of water, proton, and membrane. It also identifies the membrane as stationary, matching the claim’s fixed membrane structure. Page numbers are not provided in our copy. (LLM, conf=0.94)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
97 more claims · 11 with their cited sources checked
Create a free account to see all 235 claims and to verify the 62 references still open.
- It may state two separate claims as one. 78
- Probably not a substantial claim. 84
Citations
Cites
Polymer Electrolyte Fuel Cell Model
Springer, T. E., Zawodzinski, T. A., & Gottesfeld, S. (1991) · Journal of The Electrochemical Society · doi:10.1149/1.2085971 · Cited by 3,528
New Insights into Perfluorinated Sulfonic-Acid Ionomers
Kusoglu, A., & Weber, A. Z. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00159 · Cited by 2,432
Kreuer, K.-D., Paddison, S. J., Spohr, E., & Schuster, M. (2004) · Chemical Reviews · doi:10.1021/cr020715f · Cited by 2,187
Review of the proton exchange membranes for fuel cell applications
Peighambardoust, S. J., Rowshanzamir, S., & Amjadi, M. (2010) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2010.05.017 · Cited by 2,186
Anion-exchange membranes in electrochemical energy systems
Varcoe, J. R., Atanassov, P., Dekel, D. R., Herring, A. M., Hickner, M. A., Kohl, P. A., Kucernak, A. R., Mustain, W. E., Nijmeijer, K., Scott, K., et al. (2014) · Energy Environ. Sci. · doi:10.1039/c4ee01303d · Cited by 2,051
Water Uptake by and Transport Through Nafion® 117 Membranes
Zawodzinski, T. A., Derouin, C., Radzinski, S., Sherman, R. J., Smith, V. T., Springer, T. E., & Gottesfeld, S. (1993) · Journal of The Electrochemical Society · doi:10.1149/1.2056194 · Cited by 1,530
A Mathematical Model of the Solid‐Polymer‐Electrolyte Fuel Cell
Bernardi, D. M., & Verbrugge, M. W. (1992) · Journal of The Electrochemical Society · doi:10.1149/1.2221251 · Cited by 1,368
Porous‐electrode theory with battery applications
Newman, J., & Tiedemann, W. (1975) · AIChE Journal · doi:10.1002/aic.690210103 · Cited by 1,255
Solid polymer electrolyte membranes for fuel cell applications—a review
Smitha, B., Sridhar, S., & Khan, A. A. (2005) · Journal of Membrane Science · doi:10.1016/j.memsci.2005.01.035 · Cited by 1,216
A Water and Heat Management Model for Proton‐Exchange‐Membrane Fuel Cells
Nguyen, T. V., & White, R. E. (1993) · Journal of The Electrochemical Society · doi:10.1149/1.2220792 · Cited by 1,134
Water transport in polymer electrolyte membrane fuel cells
Jiao, K., & Li, X. (2011) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2010.06.002 · Cited by 1,086 · cited 2×
“a limitation to the use of this model by the review of Jiao and Li [10].”
BackgroundMethodDetermination of water diffusion coefficients in perfluorosulfonate ionomeric membranes
Zawodzinski, T. A., Neeman, M., Sillerud, L. O., & Gottesfeld, S. (1991) · The Journal of Physical Chemistry · doi:10.1021/j100168a060 · Cited by 987
Proton Conductivity of Nafion 117 as Measured by a Four‐Electrode AC Impedance Method
Sone, Y., Ekdunge, P., & Simonsson, D. (1996) · Journal of The Electrochemical Society · doi:10.1149/1.1836625 · Cited by 945
Mathematical model of a gas diffusion electrode bonded to a polymer electrolyte
Bernardi, D. M., & Verbrugge, M. W. (1991) · AIChE Journal · doi:10.1002/aic.690370805 · Cited by 851
Computational fluid dynamics modeling of proton exchange membrane fuel cells
Um, S., Wang, C. Y., & Chen, K. S. (2000) · Journal of The Electrochemical Society · doi:10.1149/1.1394090 · Cited by 756
Modeling Transport in Polymer-Electrolyte Fuel Cells
Weber, A. Z., & Newman, J. (2004) · Chemical Reviews · doi:10.1021/cr020729l · Cited by 738 · cited 6×
“Where a diffusion model is required for the dissolved gas, it is common to assume that the dissolved gas concentration (cgas) is low enough that Fick’s law can be applied [9]:”
BackgroundResultInfluentialWater and Thermal Management in Solid‐Polymer‐Electrolyte Fuel Cells
Fuller, T. F., & Newman, J. (1993) · Journal of The Electrochemical Society · doi:10.1149/1.2220960 · Cited by 669
Modeling of Proton Exchange Membrane Fuel Cell Performance with an Empirical Equation
Kim, J., Lee, S., Srinivasan, S., & Chamberlin, C. E. (1995) · Journal of The Electrochemical Society · doi:10.1149/1.2050072 · Cited by 656
A Critical Review of Modeling Transport Phenomena in Polymer-Electrolyte Fuel Cells
Weber, A. Z., Borup, R. L., Darling, R. M., Das, P. K., Dursch, T. J., Gu, W., Harvey, D., Kusoglu, A., Litster, S., Mench, M. M., et al. (2014) · Journal of The Electrochemical Society · doi:10.1149/2.0751412jes · Cited by 598
The water content dependence of electro-osmotic drag in proton-conducting polymer electrolytes
Zawodzinski, T. A., Davey, J., Valerio, J., & Gottesfeld, S. (1995) · Electrochimica Acta · doi:10.1016/0013-4686(94)00277-8 · Cited by 586 · cited 3×
“However, several later studies have presented evidence that the electroosmotic drag coefficient is constant and very close to unity up to a critical water content associated with the liquid‐ equilibration phase transition, whereafter it rises linearly (data tabulated in Table 7) [80,87,103,107]: i re 7.”
BackgroundMethodModeling and Experimental Diagnostics in Polymer Electrolyte Fuel Cells
Springer, T. E., Wilson, M. S., & Gottesfeld, S. (1993) · Journal of The Electrochemical Society · doi:10.1149/1.2221120 · Cited by 581
Water Uptake of Perfluorosulfonic Acid Membranes from Liquid Water and Water Vapor
Hinatsu, J. T., Mizuhata, M., & Takenaka, H. (1994) · Journal of The Electrochemical Society · doi:10.1149/1.2054951 · Cited by 518 · cited 2×
“measured the following sorption isotherm at 80 ◦C [55]:”
BackgroundDiffusion of Water in Nafion 115 Membranes
Motupally, S., Becker, A. J., & Weidner, J. W. (2000) · Journal of The Electrochemical Society · doi:10.1149/1.1393879 · Cited by 478
Transport in Polymer-Electrolyte Membranes
Weber, A. Z., & Newman, J. (2004) · Journal of The Electrochemical Society · doi:10.1149/1.1639157 · Cited by 462
Zatoń, M., Rozière, J., & Jones, D. J. (2017) · Sustainable Energy & Fuels · doi:10.1039/c7se00038c · Cited by 435
A review on water balance in the membrane electrode assembly of proton exchange membrane fuel cells
Dai, W., Wang, H., Yuan, X.-Z., Martin, J. J., Yang, D., Qiao, J., & Ma, J. (2009) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2009.09.017 · Cited by 420
Transport in Polymer-Electrolyte Membranes
Weber, A. Z., & Newman, J. (2003) · Journal of The Electrochemical Society · doi:10.1149/1.1580822 · Cited by 411
Characterization of polymer electrolytes for fuel cell applications
ZAWODZINSKIJR, T., SPRINGER, T., URIBE, F., & GOTTESFELD, S. (1993) · Solid State Ionics · doi:10.1016/0167-2738(93)90295-e · Cited by 378
Water‐sorption and transport properties of Nafion 117 H
Morris, D. R., & Sun, X. (1993) · Journal of Applied Polymer Science · doi:10.1002/app.1993.070500816 · Cited by 377
The Chemical and Structural Nature of Proton Exchange Membrane Fuel Cell Properties
Hickner, M. A., & Pivovar, B. S. (2005) · Fuel Cells · doi:10.1002/fuce.200400064 · Cited by 376
Khandelwal, M., & Mench, M. M. (2006) · Journal of Power Sources · doi:10.1016/j.jpowsour.2006.06.092 · Cited by 359 · cited 1×
“1–1 W m−1 K−1; data have been reported as a function of temperature and water content [12,161].”
BackgroundWater Management in PEM Fuel Cells
Berg, P., Promislow, K., St. Pierre, J., Stumper, J., & Wetton, B. (2004) · Journal of The Electrochemical Society · doi:10.1149/1.1641033 · Cited by 353 · cited 2×
“[33] gives cf = 1200 mol m−3 which seems to be erroneous for Nafion 1100 if measured against the dry density.”
BackgroundWater sorption, desorption and transport in Nafion membranes
Majsztrik, P. W., Satterfield, M. B., Bocarsly, A. B., & Benziger, J. B. (2007) · Journal of Membrane Science · doi:10.1016/j.memsci.2007.06.022 · Cited by 348
Tang, Y., Karlsson, A. M., Santare, M. H., Gilbert, M., Cleghorn, S., & Johnson, W. B. (2006) · Materials Science and Engineering: A · doi:10.1016/j.msea.2006.03.055 · Cited by 316 · cited 1×
“01 per unit λ in unreinforced membranes [1,39,150]; corresponding measurements on reinforced expanded polytetrafluoroethylene (ePTFE) GORE-SELECT membranes gave inelastic expansion strains about 5 times lower [151].”
BackgroundTransient analysis of polymer electrolyte fuel cells
Wang, Y., & Wang, C.-Y. (2005) · Electrochimica Acta · doi:10.1016/j.electacta.2004.08.022 · Cited by 310 · cited 2×
“Models that focus on conditions of vapour equilibration, especially those based on the Springer model and its transient extension, may ignore pressure gradients altogether [39,124,145].”
BackgroundMethodWater Management in Cathode Catalyst Layers of PEM Fuel Cells
Eikerling, M. (2006) · Journal of The Electrochemical Society · doi:10.1149/1.2160435 · Cited by 295
Eikerling, M., Kharkats, Y. I., Kornyshev, A. A., & Volfkovich, Y. M. (1998) · Journal of The Electrochemical Society · doi:10.1149/1.1838700 · Cited by 291
Jiao, K., & Li, X. (2009) · Electrochimica Acta · doi:10.1016/j.electacta.2009.06.072 · Cited by 289
Absorption, Desorption, and Transport of Water in Polymer Electrolyte Membranes for Fuel Cells
Ge, S., Li, X., Yi, B., & Hsing, I.-M. (2005) · Journal of The Electrochemical Society · doi:10.1149/1.1899263 · Cited by 288 · cited 4×
“have clearly demonstrated [63] that absorption-desorption asymmetries [110,136] in fits to (90) can be explained by understanding that the true thermodynamic driving force is the activity difference as expressed in (89); the nonlinearity of the sorption isotherm then explains the resulting asymmetry when expressed in…”
BackgroundMethodInfluentialExperimental Determination of the Transport Number of Water in Nafion 117 Membrane
Fuller, T. F., & Newman, J. (1992) · Journal of The Electrochemical Society · doi:10.1149/1.2069407 · Cited by 278
Modeling of Conductive Transport in Proton-Exchange Membranes for Fuel Cells
Thampan, T., Malhotra, S., Tang, H., & Datta, R. (2000) · Journal of The Electrochemical Society · doi:10.1149/1.1393890 · Cited by 267
On the modeling of water transport in polymer electrolyte membrane fuel cells
Wu, H., Li, X., & Berg, P. (2009) · Electrochimica Acta · doi:10.1016/j.electacta.2009.06.070 · Cited by 266
Modelling the PEM fuel cell cathode
BROKA, K., & EKDUNGE, P. (1997) · Journal of Applied Electrochemistry · doi:10.1023/a:1018476612810 · Cited by 243
Two-Phase Transport in Polymer Electrolyte Fuel Cells with Bilayer Cathode Gas Diffusion Media
Pasaogullari, U., Wang, C.-Y., & Chen, K. S. (2005) · Journal of The Electrochemical Society · doi:10.1149/1.1938067 · Cited by 240
Electroosmotic drag in polymer electrolyte membranes: an electrophoretic NMR study
Ise, M., Kreuer, K. D., & Maier, J. (1999) · Solid State Ionics · doi:10.1016/s0167-2738(99)00178-2 · Cited by 235
Zamel, N., & Li, X. (2013) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2012.07.002 · Cited by 217
Structure/property relationship of Nafion XL composite membranes
Shi, S., Weber, A. Z., & Kusoglu, A. (2016) · Journal of Membrane Science · doi:10.1016/j.memsci.2016.06.004 · Cited by 209
Qiu, D., Peng, L., Lai, X., Ni, M., & Lehnert, W. (2019) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2019.109289 · Cited by 208
Vapor Pressure Tables for Water
Bridgeman, O. C., & Aldrich, E. W. (1964) · Journal of Heat Transfer · doi:10.1115/1.3687121 · Cited by 205
Andersson, M., Beale, S. B., Espinoza, M., Wu, Z., & Lehnert, W. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.08.010 · Cited by 204
Large-scale multi-phase simulation of proton exchange membrane fuel cell
Zhang, G., Xie, X., Xie, B., Du, Q., & Jiao, K. (2019) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2018.10.122 · Cited by 196
Tang, Y., Kusoglu, A., Karlsson, A. M., Santare, M. H., Cleghorn, S., & Johnson, W. B. (2008) · Journal of Power Sources · doi:10.1016/j.jpowsour.2007.09.093 · Cited by 189
Membrane degradation in PEM fuel cells: From experimental results to semi-empirical degradation laws
Chandesris, M., Vincent, R., Guetaz, L., Roch, J.-S., Thoby, D., & Quinaud, M. (2017) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2017.02.116 · Cited by 186 · cited 1×
“gave a similar semi-empirical expression, including potential and temperature dependence of kdeg and assuming thickness-dependent degradation (assuming constant reaction rate with crossover flux) [185]:”
BackgroundÜber Erstarrungs- und Quellugserscheinungen von Gelatine
von Schroeder, P. (1903) · Zeitschrift für Physikalische Chemie · doi:10.1515/zpch-1903-4503 · Cited by 179
Non-Fickian Water Vapor Sorption Dynamics by Nafion Membranes
Satterfield, M. B., & Benziger, J. B. (2008) · The Journal of Physical Chemistry B · doi:10.1021/jp7103243 · Cited by 174
Sorption in Proton-Exchange Membranes
Choi, P., & Datta, R. (2003) · Journal of The Electrochemical Society · doi:10.1149/1.1623495 · Cited by 171
Quasi-3D modeling of water transport in polymer electrolyte fuel cells
Kulikovsky, A. A. (2003) · Journal of The Electrochemical Society · doi:10.1149/1.1611489 · Cited by 171 · cited 11×
“Kulikovsky extended the above expression to a super‐saturated or LE condition [57]:”
BackgroundMethodInfluentialModelling of heat, mass and charge transfer in a PEMFC single cell
Ramousse, J., Deseure, J., Lottin, O., Didierjean, S., & Maillet, D. (2005) · Journal of Power Sources · doi:10.1016/j.jpowsour.2005.01.067 · Cited by 165
A phenomenological model of water transport in a proton exchange membrane fuel cell
Janssen, G. J. M. (2001) · Journal of The Electrochemical Society · doi:10.1149/1.1415031 · Cited by 164 · cited 4×
“The Weber–Newman theory argues with support from Janssen that liquid water content, as distinct from water content dissolved in the membrane, must be modelled explicitly to allow a pressure gradient to drive liquid water flow alongside the chemical potential gradient [9,96]; this point is analogous to the analysis by…”
BackgroundMethodResultInfluentialTransport parameters for the modelling of water transport in ionomer membranes for PEM-fuel cells
Meier, F., & Eigenberger, G. (2004) · Electrochimica Acta · doi:10.1016/j.electacta.2003.12.004 · Cited by 158
Shah, A. A., Ralph, T. R., & Walsh, F. C. (2009) · Journal of The Electrochemical Society · doi:10.1149/1.3077573 · Cited by 149 · cited 1×
“to incorporate the full chemical mechanism for the Fenton reactions and consequent ‘unzipping’ of the membrane structure [186].”
BackgroundTransport phenomena in polymeric membrane fuel cells
Costamagna, P. (2001) · Chemical Engineering Science · doi:10.1016/s0009-2509(00)00232-3 · Cited by 147
Transient non-isothermal model of a polymer electrolyte fuel cell
Shah, A. A., Kim, G.-S., Sui, P. C., & Harvey, D. (2007) · Journal of Power Sources · doi:10.1016/j.jpowsour.2006.09.022 · Cited by 146 · cited 1×
“Thus, the stationary proton conduction Equation (6) is applied alongside (108) in the typical transient formulation of the Springer model [124,159].”
MethodBuildup of nitrogen in direct hydrogen polymer-electrolyte fuel cell stacks
Ahluwalia, R. K., & Wang, X. (2007) · Journal of Power Sources · doi:10.1016/j.jpowsour.2007.01.032 · Cited by 145 · cited 1×
“Various studies have reported Nafion 1100 permeation data additionally for CO2 and N2, including the functional relationship with relative humidity and temperature [169,170].”
BackgroundKim, S., & Mench, M. M. (2009) · Journal of Membrane Science · doi:10.1016/j.memsci.2008.11.043 · Cited by 143
Non-isothermal transient modeling of water transport in PEM fuel cells
Wu, H., Berg, P., & Li, X. (2007) · Journal of Power Sources · doi:10.1016/j.jpowsour.2006.11.061 · Cited by 138
Stresses in Proton Exchange Membranes Due to Hygro-Thermal Loading
Tang, Y., Santare, M. H., Karlsson, A. M., Cleghorn, S., & Johnson, W. B. (2006) · Journal of Fuel Cell Science and Technology · doi:10.1115/1.2173666 · Cited by 135
Wong, K. H., & Kjeang, E. (2015) · ChemSusChem · doi:10.1002/cssc.201402957 · Cited by 131 · cited 1×
“Fe2+ and Fe3+ ions as contaminants have been described with diffusivities DFe2+ ≈ 4 × 10−10 m2 s−1 and DFe3+ ≈ 4 × 10−11 m2 s−1 at T = 95 ◦C [177,178].”
Transport in Polymer-Electrolyte Membranes
Weber, A. Z., & Newman, J. (2004) · Journal of The Electrochemical Society · doi:10.1149/1.1639158 · Cited by 131 · cited 10×
“The three most experimentally accessible choices for the definition of the three independent transport properties, following the Weber–Newman scheme, are [65]:”
BackgroundMethodInfluentialBaik, K. D., & Kim, M. S. (2011) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2010.09.046 · Cited by 128 · cited 1×
“Studies have indicated particularly low permeability for N2 (<10−15 mol m−1 s−1 Pa−1) both through Nafion 1100 and GORE PRIMEA catalyst-coated membranes [170,171].”
BackgroundAn overview of electro-osmosis in fuel cell polymer electrolytes
Pivovar, B. S. (2006) · Polymer · doi:10.1016/j.polymer.2006.02.071 · Cited by 126 · cited 3×
“Quoted values of ξL for the liquid-equilibrated membrane vary across a wide range from 2 to 5 [105].”
BackgroundInfluentialMicromechanical analysis of ionic clustering in Nafion perfluorinated membrane
Li, J., & Nemat‐Nasser, S. (2000) · Mechanics of Materials · doi:10.1016/s0167-6636(00)00002-8 · Cited by 123
DeCaluwe, S. C., Baker, A. M., Bhargava, P., Fischer, J. E., & Dura, J. A. (2018) · Nano Energy · doi:10.1016/j.nanoen.2018.01.008 · Cited by 122 · cited 1×
“Recent analysis has indicated that a lamellar structure forms for particularly thin films, and that total water uptake varies non-monotonically with film thickness [71].”
BackgroundGas-Crossover and Membrane-Pinhole Effects in Polymer-Electrolyte Fuel Cells
Weber, A. Z. (2008) · Journal of The Electrochemical Society · doi:10.1149/1.2898130 · Cited by 122
Huang, J., Li, Z. Y., & Zhang, J. (2017) · Frontiers in Energy · doi:10.1007/s11708-017-0490-6 · Cited by 121
A Multi‐Scale Dynamic Mechanistic Model for the Transient Analysis of PEFCs
Franco, A. A., Schott, P., Jallut, C., & Maschke, B. (2007) · Fuel Cells · doi:10.1002/fuce.200500204 · Cited by 119 · cited 1×
“In general it is common to consider that the relaxation timescales for proton conductivity are significantly more rapid than other transport processes, and so a quasistatic proton conduction model can be used in conjunction with transient transport models for water content and for species transport in other regions of…”
BackgroundFutter, G. A., Latz, A., & Jahnke, T. (2019) · Journal of Power Sources · doi:10.1016/j.jpowsour.2018.10.085 · Cited by 118 · cited 2×
“incorporated the role of Fe2+ and Fe3+ ion transport explicitly [178].”
BackgroundThe effect of membrane thickness on the conductivity of Nafion
Tsampas, M. N., Pikos, A., Brosda, S., Katsaounis, A., & Vayenas, C. G. (2006) · Electrochimica Acta · doi:10.1016/j.electacta.2005.08.021 · Cited by 118 · cited 1×
“, who raise the possibility that the measured ohmic resistance of the membrane is, in fact, dominated by an interfacial membrane resistance for proton transfer across the liquid water-membrane boundary [119].”
BackgroundNonisothermal Modeling of Polymer Electrolyte Fuel Cells
Ju, H., Wang, C.-Y., Cleghorn, S., & Beuscher, U. (2005) · Journal of The Electrochemical Society · doi:10.1149/1.1943591 · Cited by 117
Setzler, B. P., & Fuller, T. F. (2015) · Journal of The Electrochemical Society · doi:10.1149/2.0361506jes · Cited by 117
Experimental Determination of Electro-Osmotic Drag Coefficient in Nafion Membrane for Fuel Cells
Ge, S., Yi, B., & Ming, P. (2006) · Journal of The Electrochemical Society · doi:10.1149/1.2203934 · Cited by 116 · cited 2×
“gave a detailed polynomial fit for electroosmotic drag coefficient as a function of water content [109].”
BackgroundMacroscopic In-Situ Modeling of Chemical Membrane Degradation in Polymer Electrolyte Fuel Cells
Wong, K. H., & Kjeang, E. (2014) · Journal of The Electrochemical Society · doi:10.1149/2.0031409jes · Cited by 113
Overcoming the shortcomings of the Nernst–Planck model
Dreyer, W., Guhlke, C., & Müller, R. (2013) · Physical Chemistry Chemical Physics · doi:10.1039/c3cp44390f · Cited by 112 · cited 2×
“[115] predicts that this experimental ratio of water flux to proton flux should tend to zero in the limit of a membrane consisting of sub-nanopores of negligible size.”
BackgroundAnalysis of Water Transport in PEFCs by Magnetic Resonance Imaging Measurement
Teranishi, K., Tsushima, S., & Hirai, S. (2006) · Journal of The Electrochemical Society · doi:10.1149/1.2167954 · Cited by 112
Rolfi, A., Oldani, C., Merlo, L., Facchi, D., & Ruffo, R. (2018) · Journal of Power Sources · doi:10.1016/j.jpowsour.2018.05.093 · Cited by 112
Theory of water management at the anode side of polymer electrolyte fuel cell membranes
Okada, T., Xie, G., & Tanabe, Y. (1996) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(96)04669-4 · Cited by 111
Water Uptake of Fuel-Cell Catalyst Layers
Kusoglu, A., Kwong, A., Clark, K. T., Gunterman, H. P., & Weber, A. Z. (2012) · Journal of The Electrochemical Society · doi:10.1149/2.031209jes · Cited by 110 · cited 4×
“showed a cell water content response towards equilibrium occurring on the order of 100 s after cell startup, which while much shorter than the above is still a significant duration compared to typical timescales of interest for transient PEMFC phenomena [69,128].”
BackgroundInfluentialModeling the phenomena of dehydration and flooding of a polymer electrolyte membrane fuel cell
Gerteisen, D., Heilmann, T., & Ziegler, C. (2009) · Journal of Power Sources · doi:10.1016/j.jpowsour.2008.10.102 · Cited by 108
Ion Transporting Composite Membranes: I . Nafion‐Impregnated Gore‐Tex
Penner, R. M., & Martin, C. R. (1985) · Journal of The Electrochemical Society · doi:10.1149/1.2113875 · Cited by 107
Measurement of Water Transport Properties Through Membrane-Electrode Assemblies
Ye, X., & Wang, C.-Y. (2007) · Journal of The Electrochemical Society · doi:10.1149/1.2737379 · Cited by 106
Modeling the Effect of Chemical Membrane Degradation on PEMFC Performance
Singh, R., Sui, P. C., Wong, K. H., Kjeang, E., Knights, S., & Djilali, N. (2018) · Journal of The Electrochemical Society · doi:10.1149/2.0351806jes · Cited by 105
Transport Phenomena in Polymer Electrolyte Membranes
Fimrite, J., Struchtrup, H., & Djilali, N. (2005) · Journal of The Electrochemical Society · doi:10.1149/1.1952627 · Cited by 104
Simulation of the Direct Methanol Fuel Cell
Meyers, J. P., & Newman, J. (2002) · Journal of The Electrochemical Society · doi:10.1149/1.1473188 · Cited by 103
Hydration of Ionomers and Schroeder’s Paradox in Nafion
Freger, V. (2009) · The Journal of Physical Chemistry B · doi:10.1021/jp806326a · Cited by 103
Zhang, L., Ma, C., & Mukerjee, S. (2003) · Electrochimica Acta · doi:10.1016/s0013-4686(03)00257-3 · Cited by 102
Futerko, P. M., & Hsing, I. (2000) · Electrochimica Acta · doi:10.1016/s0013-4686(99)00394-1 · Cited by 100
The effects of water and microstructure on the performance of polymer electrolyte fuel cells
Shah, A. A., Kim, G.-S., Gervais, W., Young, A., Promislow, K., Li, J., & Ye, S. (2006) · Journal of Power Sources · doi:10.1016/j.jpowsour.2006.02.085 · Cited by 99
Poroelectroelastic theory of water sorption and swelling in polymer electrolyte membranes
Eikerling, M. H., & Berg, P. (2011) · Soft Matter · doi:10.1039/c1sm05273j · Cited by 98
Computational study of water transport in proton exchange membrane fuel cells
Um, S., & Wang, C.-Y. (2006) · Journal of Power Sources · doi:10.1016/j.jpowsour.2005.05.095 · Cited by 98 · cited 1×
“In spite of evidence from the aforementioned studies that a liquid-equilibrated state elevates the electroosmotic drag coefficient, some simulations assumed ξ = 1 uniformly [57,108].”
BackgroundDynamic model of solid polymer fuel cell water management
van Bussel, H. P. L. H., Koene, F. G. H., & Mallant, R. K. A. M. (1998) · Journal of Power Sources · doi:10.1016/s0378-7753(97)02744-4 · Cited by 98
Futter, G. A., Gazdzicki, P., Friedrich, K. A., Latz, A., & Jahnke, T. (2018) · Journal of Power Sources · doi:10.1016/j.jpowsour.2018.04.070 · Cited by 94
Khattra, N. S., Karlsson, A. M., Santare, M. H., Walsh, P., & Busby, F. C. (2012) · Journal of Power Sources · doi:10.1016/j.jpowsour.2012.04.065 · Cited by 94
Two-Phase Dynamic Modeling of PEMFCs and Simulation of Cyclo-Voltammograms
Ziegler, C., Yu, H. M., & Schumacher, J. O. (2005) · Journal of The Electrochemical Society · doi:10.1149/1.1946408 · Cited by 94
Constitutive response and mechanical properties of PFSA membranes in liquid water
Kusoglu, A., Tang, Y., Lugo, M., Karlsson, A. M., Santare, M. H., Cleghorn, S., & Johnson, W. B. (2009) · Journal of Power Sources · doi:10.1016/j.jpowsour.2009.08.010 · Cited by 91
The Membrane–Electrode Interface in PEFCs
Pivovar, B. S., & Kim, Y. S. (2007) · Journal of The Electrochemical Society · doi:10.1149/1.2740005 · Cited by 90 · cited 1×
“Pivovar and Kim reported an experimental measurement of the ionic resistance associated with the CL–membrane contact, for a directly painted Nafion-based membrane-electrode assembly (MEA), as being at least 8 mΩ cm2 [117]; however, results from commercially manufactured MEAs were not reported and it has subsequently b…”
ResultA theoretical study of membrane constraint in polymer‐electrolyte fuel cells
Weber, A. Z., & Newman, J. (2004) · AIChE Journal · doi:10.1002/aic.10230 · Cited by 88
A three-dimensional PEM fuel cell model with consistent treatment of water transport in MEA
Meng, H. (2006) · Journal of Power Sources · doi:10.1016/j.jpowsour.2006.07.022 · Cited by 83
Numerical analysis of gas crossover effects in polymer electrolyte fuel cells (PEFCs)
Nam, J., Chippar, P., Kim, W., & Ju, H. (2010) · Applied Energy · doi:10.1016/j.apenergy.2010.05.023 · Cited by 82
Water transport through a PEM fuel cell: A one-dimensional model with heat transfer effects
Falcão, D. S., Oliveira, V. B., Rangel, C. M., Pinho, C., & Pinto, A. M. F. R. (2009) · Chemical Engineering Science · doi:10.1016/j.ces.2009.01.049 · Cited by 80 · cited 1×
“distinguished between the anode as being exclusively vapour-equilibrated, and the cathode side, where the water produced through the cathode reaction (oxygen reduction) is initially membrane-dissolved, as liquid-equilibrated [36,144].”
BackgroundUnderstanding Water Uptake and Transport in Nafion Using X-ray Microtomography
Hwang, G. S., Parkinson, D. Y., Kusoglu, A., MacDowell, A. A., & Weber, A. Z. (2013) · ACS Macro Letters · doi:10.1021/mz300651a · Cited by 79
Adachi, M., Navessin, T., Xie, Z., Frisken, B., & Holdcroft, S. (2009) · Journal of The Electrochemical Society · doi:10.1149/1.3116922 · Cited by 79 · cited 2×
“demonstrated experimentally that allowing liquid equilibration of one face of the membrane, while maintaining vapour equilibration on the other, greatly increased the permeation rate compared to a vapour–vapour membrane, due to the elimination of one interfacial resistance [126].”
BackgroundMembrane degradation model for 3D CFD analysis of fuel cell performance as a function of time
Karpenko-Jereb, L., Sternig, C., Fink, C., & Tatschl, R. (2016) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2016.05.229 · Cited by 77
Relationship among Microstructure, Ionomer Property and Proton Transport in Pseudo Catalyst Layers
Iden, H., Sato, K., Ohma, A., & Shinohara, K. (2011) · Journal of The Electrochemical Society · doi:10.1149/1.3598141 · Cited by 76
Dobson, P., Lei, C., Navessin, T., & Secanell, M. (2012) · Journal of The Electrochemical Society · doi:10.1149/2.041205jes · Cited by 75
Gas permeation in perflurosulfonated membranes: Influence of temperature and relative humidity
Giacinti Baschetti, M., Minelli, M., Catalano, J., & Sarti, G. C. (2013) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2013.06.104 · Cited by 74
Kundu, S., Fowler, M. W., Simon, L. C., Abouatallah, R., & Beydokhti, N. (2008) · Journal of Power Sources · doi:10.1016/j.jpowsour.2008.05.074 · Cited by 74
Influence of catalyst structure on PEM fuel cell performance – A numerical investigation
Carcadea, E., Varlam, M., Marinoiu, A., Raceanu, M., Ismail, M. S., & Ingham, D. B. (2019) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2018.12.155 · Cited by 73
Understanding the Effects of Compression and Constraints on Water Uptake of Fuel-Cell Membranes
Kusoglu, A., Kienitz, B. L., & Weber, A. Z. (2011) · Journal of The Electrochemical Society · doi:10.1149/2.097112jes · Cited by 72 · cited 3×
“Both experimental and theoretical studies have implicated the load due to membrane swelling in a lowering of the effective water content of the membrane [128,148,152], with an experimental cap on water uptake of λmax = 6.”
BackgroundMethodInterfacial Water Transport Effects in Proton-Exchange Membranes
Kientiz, B., Yamada, H., Nonoyama, N., & Weber, A. Z. (2011) · Journal of Fuel Cell Science and Technology · doi:10.1115/1.4002398 · Cited by 72
Numerical and experimental analysis of liquid water distribution in PEM fuel cells
Penga, Ž., Bergbreiter, C., Barbir, F., & Scholta, J. (2019) · Energy Conversion and Management · doi:10.1016/j.enconman.2019.03.082 · Cited by 70
A vaporization-exchange model for water sorption and flux in Nafion
Monroe, C. W., Romero, T., Mérida, W., & Eikerling, M. (2008) · Journal of Membrane Science · doi:10.1016/j.memsci.2008.05.080 · Cited by 69
The Membrane–Electrode Interface in PEFCs
Kim, Y. S., & Pivovar, B. S. (2010) · Journal of The Electrochemical Society · doi:10.1149/1.3481581 · Cited by 68
Two-Phase Transport in PEM Fuel Cell Cathodes
Gurau, V., Zawodzinski, T. A., & Mann, J. A. (2008) · Journal of Fuel Cell Science and Technology · doi:10.1115/1.2821597 · Cited by 68
Effect of Interfacial Water Transport Resistance on Coupled Proton and Water Transport Across Nafion
Cheah, M. J., Kevrekidis, I. G., & Benziger, J. (2011) · The Journal of Physical Chemistry B · doi:10.1021/jp204785t · Cited by 68
On the constitutive relations for catalyst coated membrane applied to in-situ fuel cell modeling
Khorasany, R. M. H., Goulet, M.-A., Alavijeh, A. S., Kjeang, E., Wang, G. G., & Rajapakse, R. K. N. D. (2014) · Journal of Power Sources · doi:10.1016/j.jpowsour.2013.11.087 · Cited by 67 · cited 1×
“It has also been established that the CL and interfacial properties may have a significant role in overall structural behaviour of the membrane [156].”
BackgroundWang, Y., Wang, S., Liu, S., Li, H., & Zhu, K. (2019) · Electrochimica Acta · doi:10.1016/j.electacta.2019.06.120 · Cited by 62
Burlatsky, S. F., Gummalla, M., O'Neill, J., Atrazhev, V. V., Varyukhin, A. N., Dmitriev, D. V., & Erikhman, N. S. (2012) · Journal of Power Sources · doi:10.1016/j.jpowsour.2012.05.005 · Cited by 62
Hu, J., Sui, P. C., Kumar, S., & Djilali, N. (2009) · Electrochimica Acta · doi:10.1016/j.electacta.2009.04.073 · Cited by 61 · cited 2×
“used DO2 = 10−9 m2 s−1, which is much higher than values proposed els where [173].”
MethodMorris, D. R. P., Liu, S. P., Villegas Gonzalez, D., & Gostick, J. T. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am503509j · Cited by 59 · cited 1×
“showed that sorption/desorption in the CL appeared to be free from hysteresis [74].”
BackgroundDegradation of Polymer-Electrolyte Membranes in Fuel Cells
Gummalla, M., Atrazhev, V. V., Condit, D., Cipollini, N., Madden, T., Kuzminyh, N. Y., Weiss, D., & Burlatsky, S. F. (2010) · Journal of The Electrochemical Society · doi:10.1149/1.3481450 · Cited by 59
Kim, T.-H., Yoo, J. H., Maiyalagan, T., & Yi, S.-C. (2019) · Applied Surface Science · doi:10.1016/j.apsusc.2019.03.113 · Cited by 59 · cited 1×
“Additionally, studies have suggested that sorbed water uptake of the CL depends upon Pt loading [69], choice of carbon support [38,72], and the solvent used in CL preparation [73].”
BackgroundInvestigation of the Impact of Interfacial Delamination on Polymer Electrolyte Fuel Cell Performance
Kim, S., Khandelwal, M., Chacko, C., & Mench, M. M. (2009) · Journal of The Electrochemical Society · doi:10.1149/1.3006398 · Cited by 58
Kosakian, A., Urbina, L. P., Heaman, A., & Secanell, M. (2020) · Electrochimica Acta · doi:10.1016/j.electacta.2020.136204 · Cited by 57
Device and Materials Modeling in PEM Fuel Cells
(2009) · Topics in Applied Physics · doi:10.1007/978-0-387-78691-9 · Cited by 57
Zhao, J., & Li, X. (2019) · Energy Conversion and Management · doi:10.1016/j.enconman.2019.02.042 · Cited by 56
The Dynamics of Platinum Precipitation in an Ion Exchange Membrane
Burlatsky, S. F., Gummalla, M., Atrazhev, V. V., Dmitriev, D. V., Kuzminyh, N. Y., & Erikhman, N. S. (2011) · Journal of The Electrochemical Society · doi:10.1149/1.3532956 · Cited by 53 · cited 2×
“described Pt2+ transport with DPt ≈ 10−10 m2 s−1 at unspecified temperature [176].”
BackgroundTransport Phenomena in Polymer Electrolyte Membranes
Fimrite, J., Carnes, B., Struchtrup, H., & Djilali, N. (2005) · Journal of The Electrochemical Society · doi:10.1149/1.1952647 · Cited by 53
Water balance simulations of a polymer-electrolyte membrane fuel cell using a two-fluid model
Berning, T., Odgaard, M., & Kær, S. K. (2011) · Journal of Power Sources · doi:10.1016/j.jpowsour.2011.03.068 · Cited by 52
Carnes, B., & Djilali, N. (2006) · Electrochimica Acta · doi:10.1016/j.electacta.2006.07.006 · Cited by 50
A Multiparadigm Modeling Investigation of Membrane Chemical Degradation in PEM Fuel Cells
Quiroga, M. A., Malek, K., & Franco, A. A. (2016) · Journal of The Electrochemical Society · doi:10.1149/2.0931514jes · Cited by 50
In-situ simulation of membrane fatigue in polymer electrolyte fuel cells
Khorasany, R. M. H., Singh, Y., Sadeghi Alavijeh, A., Rajapakse, R. K. N. D., & Kjeang, E. (2017) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2017.01.173 · Cited by 49 · cited 1×
“In general, membrane fatigue models have been used for durability analysis [184] but have not yet been applied to a direct prediction of performance deterioration.”
MethodWiezell, K., Gode, P., & Lindbergh, G. (2006) · Journal of The Electrochemical Society · doi:10.1149/1.2172559 · Cited by 49
Mathematical Modelling of Cation Contamination in a Proton‐exchange Membrane
Weber, A. Z., & Delacourt, C. (2008) · Fuel Cells · doi:10.1002/fuce.200800044 · Cited by 49
New directions in perfluoroalkyl sulfonic acid–based proton-exchange membranes
Yandrasits, M., Lindell, M. J., & Hamrock, S. J. (2019) · Current Opinion in Electrochemistry · doi:10.1016/j.coelec.2019.10.012 · Cited by 49
Analysis of Water Adsorption and Condensation in Catalyst Layers for Polymer Electrolyte Fuel Cells
Mashio, T., Sato, K., & Ohma, A. (2014) · Electrochimica Acta · doi:10.1016/j.electacta.2014.07.058 · Cited by 48
In-Situ Measurement of Electroosmotic Drag Coefficient in Nafion Membrane for the PEMFC
Peng, Z., Morin, A., Huguet, P., Schott, P., & Pauchet, J. (2011) · The Journal of Physical Chemistry B · doi:10.1021/jp205291f · Cited by 44
Murahashi, T., Naiki, M., & Nishiyama, E. (2006) · Journal of Power Sources · doi:10.1016/j.jpowsour.2006.07.043 · Cited by 43
(2016) · Green Energy and Technology · doi:10.1007/978-1-4471-5677-2 · Cited by 43
Transport phenomena in fuel cells: from microscale to macroscale
Djilali, N., & Sui, P. (2008) · International journal of computational fluid dynamics · doi:10.1080/10618560701740017 · Cited by 43
Transport properties of proton- and hydroxide-exchange membranes for fuel cells
Wang, X., McClure, J. P., & Fedkiw, P. S. (2012) · Electrochimica Acta · doi:10.1016/j.electacta.2012.06.098 · Cited by 42 · cited 2×
“However, several later studies have presented evidence that the electroosmotic drag coefficient is constant and very close to unity up to a critical water content associated with the liquid‐ equilibration phase transition, whereafter it rises linearly (data tabulated in Table 7) [80,87,103,107]: i re 7.”
BackgroundGebert, M., Ghielmi, A., Merlo, L., Corasaniti, M., & Arcella, V. (2010) · ECS Transactions · doi:10.1149/1.3428998 · Cited by 41
Water sorption and expansion of an ionomer membrane constrained by fuel cell electrodes
Goulet, M.-A., Arbour, S., Lauritzen, M., & Kjeang, E. (2015) · Journal of Power Sources · doi:10.1016/j.jpowsour.2014.10.040 · Cited by 40
A novel membrane transport model for polymer electrolyte fuel cell simulations
Karpenko-Jereb, L., Innerwinkler, P., Kelterer, A.-M., Sternig, C., Fink, C., Prenninger, P., & Tatschl, R. (2014) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2014.02.083 · Cited by 40 · cited 4×
“97 ≤ aw ≤ 1 to represent Schröder’s paradox, wherein the VE sorption isotherm shows no temperature dependence, but a temperature dependence is incorporated in the LE part [59]:”
BackgroundInfluentialAbsence of Schroeder's paradox: Experimental evidence for water-swollen Nafion® membranes
Jeck, S., Scharfer, P., & Kind, M. (2011) · Journal of Membrane Science · doi:10.1016/j.memsci.2011.02.036 · Cited by 39
A computational model of a PEM fuel cell with finite vapor absorption rate
Vorobev, A., Zikanov, O. Y., & Shamim, T. (2007) · Journal of Power Sources · doi:10.1016/j.jpowsour.2006.12.071 · Cited by 38
CFD Simulation of an Industrial PEM Fuel Cell with Local Degradation Effects
Fink, C., Gößling, S., Karpenko‐Jereb, L., & Urthaler, P. (2020) · Fuel Cells · doi:10.1002/fuce.201900197 · Cited by 36 · cited 1×
“This model also altered membrane thickness directly in proportion to total mass loss, and has recently been incorporated into a 3D full cell performance model [190].”
MethodMazumder, S. (2005) · Journal of The Electrochemical Society · doi:10.1149/1.1940747 · Cited by 35
Water and charge transport models in proton exchange membranes: An overview
Nasef, M. M., & Ali, A. A. (2011) · Desalination · doi:10.1016/j.desal.2011.06.054 · Cited by 35
Electrochemical Measurement of the Oxygen Permeation Rate through Polymer Electrolyte Membranes
Zhang, J., Gasteiger, H. A., & Gu, W. (2013) · Journal of The Electrochemical Society · doi:10.1149/2.081306jes · Cited by 35
Modeling of ion and water transport in the polymer electrolyte membrane of PEM fuel cells
Baschuk, J. J., & Li, X. (2010) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2009.10.032 · Cited by 33 · cited 1×
“[93], Baschuk and Li tabulated third-order polynomial fit data for the water-content dependence of conductivity, at a range of temperatures from T = 20 ◦C to T = 70 ◦C [94].”
BackgroundA pseudo three-dimensional, two-phase, non-isothermal model of proton exchange membrane fuel cell
Rizvandi, O. B., & Yesilyurt, S. (2019) · Electrochimica Acta · doi:10.1016/j.electacta.2019.02.018 · Cited by 33
Rangel-Cárdenas, A., & Koper, G. (2017) · Materials · doi:10.3390/ma10060576 · Cited by 33
Coulon, R., Bessler, W., & Franco, A. A. (2010) · ECS Transactions · doi:10.1149/1.3414024 · Cited by 32
Analysis of a cathode catalyst layer model for a polymer electrolyte fuel cell
Berg, P., Novruzi, A., & Promislow, K. (2006) · Chemical Engineering Science · doi:10.1016/j.ces.2006.01.033 · Cited by 32
Liu, X., Lou, G., & Wen, Z. (2009) · Journal of Power Sources · doi:10.1016/j.jpowsour.2009.11.019 · Cited by 31
Non-equilibrium thermodynamic model of water sorption in Nafion membranes
Klika, V., Kubant, J., Pavelka, M., & Benziger, J. B. (2017) · Journal of Membrane Science · doi:10.1016/j.memsci.2017.06.025 · Cited by 30
Ziegler, C., & Gerteisen, D. (2008) · Journal of Power Sources · doi:10.1016/j.jpowsour.2008.11.071 · Cited by 29
Influence of the water uptake in the catalyst layer for the proton exchange membrane fuel cells
Jung, C.-Y., & Yi, S.-C. (2013) · Electrochemistry Communications · doi:10.1016/j.elecom.2013.07.037 · Cited by 27
Hasan, M., Goshtasbi, A., Chen, J., Santare, M. H., & Ersal, T. (2018) · Journal of The Electrochemical Society · doi:10.1149/2.0371806jes · Cited by 25 · cited 2×
“incorporated in isotropic swelling model combined with a viscoelastic-plastic mechanical model into an electrochemical analysis: this allowed strain to be predicted as a function of membrane hydration, but no feedback from the mechanical response was considered to the water transport and uptake [31].”
MethodA Look at the Multiphase Mixture Model for PEM Fuel Cell Simulations
(2008) · doi:10.1149/1.2929658 · Cited by 23
Catalyst Layer Operation in PEM Fuel Cells: From Structural Pictures to Tractable Models
Andreaus, B., & Eikerling, M. H. (2008) · Topics in applied physics · doi:10.1007/978-0-387-78691-9_3 · Cited by 22
Pore-Water Morphological Transitions in Polymer Electrolyte of a Fuel Cell
Hwang, G. S., Kaviany, M., Nam, J. H., Kim, M. H., & Son, S. Y. (2009) · Journal of The Electrochemical Society · doi:10.1149/1.3186027 · Cited by 21 · cited 1×
“employed the van Genuchten model for the degree of saturation in partially saturated porous media to describe the membrane as governed by capillary hydrodynamics (detailed formulas are given in the referenced work) [143].”
MethodOn water transport in polymer electrolyte membranes during the passage of current
Berning, T. (2011) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2011.04.079 · Cited by 20 · cited 2×
“[113] is incorrect: the authors mistakenly argue that there is no contribution from electroosmotic drag to water transport in the bulk of the membrane, on the basis that a constant electroosmotic drag coefficient allows an equation for water transport to be written that contains only the diffusional term.”
BackgroundA Nonisothermal PEM Fuel Cell Model Including Two Water Transport Mechanisms in the Membrane
Steinkamp, K., Schumacher, J. O., Goldsmith, F., Ohlberger, M., & Ziegler, C. (2008) · Journal of Electrochemical Energy Conversion and Storage · doi:10.1115/1.2822884 · Cited by 20
Water Transport Across a Polymer Electrolyte Membrane under Thermal Gradients
Fu, R. S., Preston, J. S., Pasaogullari, U., Shiomi, T., Miyazaki, S., Tabuchi, Y., Hussey, D. S., & Jacobson, D. L. (2011) · Journal of The Electrochemical Society · doi:10.1149/1.3530794 · Cited by 19
Simple Mathematical Model for Water Diffusion in Nafion Membranes
St-Pierre, J. (2007) · Journal of The Electrochemical Society · doi:10.1149/1.2392607 · Cited by 19
Jung, C.-Y., Lee, C.-S., & Yi, S.-C. (2008) · Journal of Membrane Science · doi:10.1016/j.memsci.2007.10.017 · Cited by 18 · cited 1×
“Models that focus on conditions of vapour equilibration, especially those based on the Springer model and its transient extension, may ignore pressure gradients altogether [39,124,145].”
BackgroundThe Model of Stress Distribution in Polymer Electrolyte Membrane
Atrazhev, V. V., Astakhova, T. Y., Dmitriev, D. V., Erikhman, N. S., Sultanov, V. I., Patterson, T., & Burlatsky, S. F. (2013) · Journal of The Electrochemical Society · doi:10.1149/2.079310jes · Cited by 16
Interfacial constraints on water and proton transport across nafion membranes
Benziger, J. B., Cheah, M. J., Klika, V., & Pavelka, M. (2015) · Journal of Polymer Science Part B Polymer Physics · doi:10.1002/polb.23794 · Cited by 12
Water transport and Schröder's Paradox in fuel cell membrane electrode assemblies
Yau, T. C., Cimenti, M., Bi, X. T., & Stumper, J. (2013) · Journal of Power Sources · doi:10.1016/j.jpowsour.2012.10.006 · Cited by 11 · cited 2×
“The frequent observation of net cathode-to-anode water transport in the presence of a water-saturated anode fuel has been described as a manifestation of Schröder’s paradox due to the liquid equilibration of the cathode [127].”
BackgroundTowards a Consistent Interpretation of Electro‐osmotic Drag in Polymer Electrolyte Membranes
Berg, P., & Stornes, M. (2016) · Fuel Cells · doi:10.1002/fuce.201500210 · Cited by 10 · cited 4×
“Recently, Berg and Stornes [114] combined a random pore network model with the detailed swelling model of Eikerling and Berg [44] to predict a variety of apparent experimental water flux to proton flux ratios, and suggested that a ‘consistent’ thermodynamic model following Dreyer et al.”
BackgroundInfluentialCoupled Proton and Water Transport in Polymer Electrolyte Membranes
Fimrite, J., Carnes, B., Struchtrup, H., & Djilali, N. (2008) · Topics in applied physics · doi:10.1007/978-0-387-78691-9_5 · Cited by 9
Numerical modeling of liquid water transport inside and across membrane in PEM fuel cells
Meng, H., Han, B., & Ruan, B. (2013) · Asia-Pacific Journal of Chemical Engineering · doi:10.1002/apj.1635 · Cited by 7 · cited 1×
“implemented the liquid saturation by means of an adapted Springer model [141]:”
MethodFriction coefficient analysis of multicomponent solute transport through polymer membranes
Sundaram, N., & Peppas, N. A. (1996) · Journal of Applied Polymer Science · doi:10.1002/(sici)1097-4628(19960404)60:1<95::aid-app11>3.0.co;2-2 · Cited by 5
Water transport law of fuel cell membranes at different current densities
Wang, Z., Zhan, Z., Tan, J., & Pan, M. (2019) · Chinese Science Bulletin · doi:10.1360/n972019-00087 · Cited by 5
Water Dynamics in a PEM Fuel Cell: Effect of Current and Humidity Transients
Davey, J., Mukundan, R., Spendelow, J., Hussey, D. S., Jacobson, D., Arif, M., & Borup, R. L. (2008) · ECS Transactions · doi:10.1149/1.2981867 · Cited by 4
Rama, P., & Chen, R. (2010) · Journal of Fuel Cell Science and Technology · doi:10.1115/1.4001004 · Cited by 3 · cited 1×
“gave independent diffusion and hydraulic pressure gradient terms in the water flux expression [147]; this would contradict the same principles of fundamental multi-component transport theory, and this model has not been taken up by other researchers.”
Result
Research works printed but not linked: 3
- The Chemours Company FC, LLC. (2017). Product Bulletin P-11: Nafion(TM) NR211 and NR212 Ion Exchange Materials: Solution Cast Membranes, The Chemours Company FC, LLC.
- The Chemours Company FC, LLC. (2016). Product Bulletin P-12: Nafion(TM) N115, N117 and N1110 Ion Exchange Materials: Extrusion Cast Membranes, The Chemours Company FC, LLC.
- Paddison, S.J., and Promislow, K.S. (2009). A Combination Model for Macroscopic Transport in Polymer-Electrolyte Membranes. Device and Materials Modeling in PEM Fuel Cells, Springer. · DOI · Paper page
Cited by
A review on lifetime prediction of proton exchange membrane fuel cells system
Hua, Z., Zheng, Z., Pahon, E., Péra, M.-C., & Gao, F. (2022) · Journal of Power Sources · doi:10.1016/j.jpowsour.2022.231256 · Cited by 289
Application of Machine Learning in Optimizing Proton Exchange Membrane Fuel Cells: A Review
Ding, R., Zhang, S., Chen, Y., Rui, Z., Hua, K., Wu, Y., Li, X., Duan, X., Wang, X., Li, J., et al. (2022) · Energy and AI · doi:10.1016/j.egyai.2022.100170 · Cited by 171
Yang, L., Nik-Ghazali, N.-N., Ali, M. A. H., Chong, W. T., Yang, Z., & Liu, H. (2023) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2023.113737 · Cited by 168
A survey of Digital Twin techniques in smart manufacturing and management of energy applications
Wang, Y., Kang, X., & Chen, Z. (2022) · Green Energy and Intelligent Transportation · doi:10.1016/j.geits.2022.100014 · Cited by 147
Pan, Y., Wang, H., & Brandon, N. P. (2021) · Journal of Power Sources · doi:10.1016/j.jpowsour.2021.230560 · Cited by 129
Metadata
- Authors
- Dickinson, E. J. F., & Smith, G.
- Affiliations
- National Physical Laboratory (GB)
- Corresponding author
- Dickinson, Edmund J. F.
- Venue
- Membranes
- Publisher
- MDPI AG
- Published
- 2020-10-28
- Volume
- 10
- Issue
- 11
- Pages
- 310
- ISSN
- 2077-0375 (ISSN-L)
- PMC
- PMC7692588
- OpenAlex
- W3097817857
- Cited by
- 109
- References
- 192
- Citations by year
- 2026: 17 · 2025: 17 · 2024: 26 · 2023: 20 · 2022: 17 · 2021: 12
- FWCI
- 0.56
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Membranes (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Fraunhofer-Publica (Fraunhofer-Gesellschaft) (submittedVersion)
- Funders
- Department for Business, Energy and Industrial Strategy, UK Government (National Measurement System)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Fuel Cells and Related Materials
- Physical Sciences › Materials Science › Materials Chemistry › Advancements in Solid Oxide Fuel Cells
- Physical Sciences › Chemical Engineering › Filtration and Separation › Membrane-based Ion Separation Techniques
- Keywords
- proton-conducting membranes, proton exchange membrane fuel cells, proton transport, moisture sorption isotherms, water diffusion coefficient, electro-osmotic drag, membrane swelling, non-isothermal transport, gas transport, membrane degradation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol and qwen3.8-omni-flash).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.