Smart Wearables for Cardiac Monitoring—Real-World Use beyond Atrial Fibrillation
Open accessThe DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
The possibilities and implementation of wearable cardiac monitoring beyond atrial fibrillation are increasing continuously. This review focuses on the real-world use and evolution of these devices for other arrhythmias, cardiovascular diseases and some of their risk factors beyond atrial fibrillation. The management of nonatrial fibrillation arrhythmias represents a broad field of wearable technologies in cardiology using Holter, event recorder, electrocardiogram (ECG) patches, wristbands and textiles. Implementation in other patient cohorts, such as ST-elevation myocardial infarction (STEMI), heart failure or sleep apnea, is feasible and expanding. In addition to appropriate accuracy, clinical studies must address the validation of clinical pathways including the appropriate device and clinical decisions resulting from the surrogate assessed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
James, S. L., Abate, D., Abate, K. H., Abay, S. M., Abbafati, C., Abbasi, N., Abbastabar, H., Abd-Allah, F., Abdela, J., Abdelalim, A., et al. (2018) · The Lancet · doi:10.1016/s0140-6736(18)32279-7 · Cited by 13,867
Vos, T., Abajobir, A. A., Abate, K. H., Abbafati, C., Abbas, K. M., Abd-Allah, F., Abdulkader, R. S., Abdulle, A. M., Abebo, T. A., Abera, S. F., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)32154-2 · Cited by 13,220
Heart Disease and Stroke Statistics—2016 Update: A Report From the American Heart Association
Mozaffarian, D., Benjamin, E. J., Go, A. S., Arnett, D. K., Blaha, M. J., Cushman, M., Das, S. R., de Ferranti, S., Després, J.-P., Fullerton, H. J., et al. (2016) · Circulation · doi:10.1161/cir.0000000000000350 · Cited by 6,596
Increased Prevalence of Sleep-Disordered Breathing in Adults
Peppard, P. E., Young, T., Barnet, J. H., Palta, M., Hagen, E. W., & Hla, K. M. (2013) · American Journal of Epidemiology · doi:10.1093/aje/kws342 · Cited by 4,618
Arnett, D. K., Blumenthal, R. S., Albert, M. A., Buroker, A. B., Goldberger, Z. D., Hahn, E. J., Himmelfarb, C. D., Khera, A., Lloyd-Jones, D., McEvoy, J. W., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000678 · Cited by 4,536
(2019) · doi:10.1161/cir.0000000000000677 · Cited by 4,501
(1992) · New England Journal of Medicine · doi:10.1056/nejm199209033271003 · Cited by 3,725 · cited 1×
“Therefore, the AI tool could identify asymptomatic LVSD at the early stage, so the treatment can be initiated to prevent HF progression and mortality.[123,124] When applied in the emergency department, the ECG-based AI algorithm outperformed NT-proBNP for identifying patients with LVSD, which could serve as a quick, i…”
MethodHannun, A. Y., Rajpurkar, P., Haghpanahi, M., Tison, G. H., Bourn, C., Turakhia, M. P., & Ng, A. Y. (2019) · Nature Medicine · doi:10.1038/s41591-018-0268-3 · Cited by 3,148
Groenewegen, A., Rutten, F. H., Mosterd, A., & Hoes, A. W. (2020) · European Journal of Heart Failure · doi:10.1002/ejhf.1858 · Cited by 2,043 · cited 1×
“0% of the adult population with an increasing incidence with increasing age [48].”
Background2019 ACC/AHA Guideline on the Primary Prevention of Cardiovascular Disease
Arnett, D. K., Blumenthal, R. S., Albert, M. A., Buroker, A. B., Goldberger, Z. D., Hahn, E. J., Himmelfarb, C. D., Khera, A., Lloyd-Jones, D., McEvoy, J. W., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.03.010 · Cited by 1,896
Schwartz, P. J., Priori, S. G., Spazzolini, C., Moss, A. J., Vincent, G. M., Napolitano, C., Denjoy, I., Guicheney, P., Breithardt, G., Keating, M. T., et al. (2001) · Circulation · doi:10.1161/01.cir.103.1.89 · Cited by 1,779
Abraham, W. T., Adamson, P. B., Bourge, R. C., Aaron, M. F., Costanzo, M. R., Stevenson, L. W., Strickland, W., Neelagaru, S., Raval, N., Krueger, S., et al. (2011) · The Lancet · doi:10.1016/s0140-6736(11)60101-3 · Cited by 1,744
Attia, Z. I., Kapa, S., Lopez-Jimenez, F., McKie, P. M., Ladewig, D. J., Satam, G., Pellikka, P. A., Enriquez-Sarano, M., Noseworthy, P. A., Munger, T. M., et al. (2019) · Nature Medicine · doi:10.1038/s41591-018-0240-2 · Cited by 1,389 · cited 5×
“The ability to detect MI and LVSD could also alert patients to seek medical care early and inform diagnostic approaches when patients arrive in the hospital.”
BackgroundInfluentialSelf-citationTelemonitoring in patients with heart failure
Chaudhry, S. I., Mattera, J. A., Curtis, J. P., Spertus, J. A., Herrin, J., Lin, Z., Phillips, C. O., Hodshon, B. V., Cooper, L. S., & Krumholz, H. M. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1010029 · Cited by 1,232
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux274 · Cited by 1,164
Artificial Intelligence and Human Trust in Healthcare: Focus on Clinicians
Asan, O., Bayrak, A. E., & Choudhury, A. (2020) · Journal of Medical Internet Research · doi:10.2196/15154 · Cited by 825
Koehler, F., Koehler, K., Deckwart, O., Prescher, S., Wegscheider, K., Kirwan, B.-A., Winkler, S., Vettorazzi, E., Bruch, L., Oeff, M., et al. (2018) · The Lancet · doi:10.1016/s0140-6736(18)31880-4 · Cited by 739
Association of daily step count and step intensity with mortality among US adults
Saint-Maurice, P. F., Troiano, R. P., Bassett, D. R., Graubard, B. I., Carlson, S. A., Shiroma, E. J., Fulton, J. E., & Matthews, C. E. (2020) · JAMA · doi:10.1001/jama.2020.1382 · Cited by 660 · cited 1×
“Recently, a number of studies assessed the relationship between health outcomes and data collected from wearable devices, such as step count, sleep duration and sleep variability [130–132].”
BackgroundBarrett, P. M., Komatireddy, R., Haaser, S., Topol, S., Sheard, J., Encinas, J., Fought, A. J., & Topol, E. J. (2014) · The American Journal of Medicine · doi:10.1016/j.amjmed.2013.10.003 · Cited by 498 · cited 1×
“demonstrated that the Zio Patch had a higher diagnostic yield for total arrhythmia detection (atrioventricular block, pause, supraventricular tachycardia, ventricular tachycardia and polymorphic ventricular tachycardia [and AF]) compared to Holter monitoring [9].”
ResultSmartwatch Algorithm for Automated Detection of Atrial Fibrillation
Bumgarner, J. M., Lambert, C. T., Hussein, A. A., Cantillon, D. J., Baranowski, B., Wolski, K., Lindsay, B. D., Wazni, O. M., & Tarakji, K. G. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.03.003 · Cited by 446 · cited 2×
“This may be reduced, to a degree, by the manual interpretation of the traces, but this also means a greater workload for healthcare professionals.[24] In the future, improvements in adaptive filters may help address this issue.”
BackgroundKo, W.-Y., Siontis, K. C., Attia, Z. I., Carter, R. E., Kapa, S., Ommen, S. R., Demuth, S. J., Ackerman, M. J., Gersh, B. J., Arruda-Olson, A. M., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.12.030 · Cited by 404 · cited 2×
“In recent years, a number of ECG-based AI algorithms have shown great performance in detecting cardiac conditions, such as LVSD [117,118], HCM [119] and MI [120].”
BackgroundMethodInfluentialSelf-citationStehlik, J., Schmalfuss, C., Bozkurt, B., Nativi-Nicolau, J., Wohlfahrt, P., Wegerich, S., Rose, K., Ray, R., Schofield, R., Deswal, A., et al. (2020) · Circulation Heart Failure · doi:10.1161/circheartfailure.119.006513 · Cited by 333 · cited 4×
“Several studies have demonstrated that wristband-, smartwatch-or patch-integrated pedometers or accelerometers are able to provide data on the activity in heart failure patients [64–68].”
BackgroundMethodInfluentialPhotoplethysmography based atrial fibrillation detection: a review
Pereira, T., Tran, N., Gadhoumi, K., Pelter, M. M., Do, D. H., Lee, R. J., Colorado, R., Meisel, K., & Hu, X. (2020) · npj Digital Medicine · doi:10.1038/s41746-019-0207-9 · Cited by 300 · cited 1×
“artefacts that make traces uninterpretable, resulting in discarded data [36].”
BackgroundRadin, J. M., Wineinger, N. E., Topol, E. J., & Steinhubl, S. R. (2020) · The Lancet Digital Health · doi:10.1016/s2589-7500(19)30222-5 · Cited by 300
Lampert, R., Olshansky, B., Heidbuchel, H., Lawless, C., Saarel, E., Ackerman, M., Calkins, H., Estes, N. A. M., Link, M. S., Maron, B. J., et al. (2013) · Circulation · doi:10.1161/circulationaha.112.000447 · Cited by 286 · cited 3×
“In fact, the use of RPM in patients with implanted devices (pacemakers, ICDs and cardiac resynchronization therapies) has been shown to be associated with a reduction in mortality, depending on the level of adherence [84,85].”
BackgroundDiagnostic utility of a novel leadless arrhythmia monitoring device.
Turakhia, M. P., Hoang, D. D., Zimetbaum, P., Miller, J. D., Froelicher, V. F., Kumar, U. N., Xu, X., Yang, F., & Heidenreich, P. A. (2013) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2013.04.017 · Cited by 258 · cited 1×
“A cross-sectional study of 26,751 consecutive patients receiving the Zio Patch for clinical indications of cardiac monitoring demonstrated high patient compliance with a significant proportion of patients who had arrhythmias suffering from these events after the initial 48 h [10], thereby reinforcing the need for long…”
BackgroundMcManus, D. D., Lee, J., Maitas, O., Esa, N., Pidikiti, R., Carlucci, A., Harrington, J., Mick, E., & Chon, K. H. (2013) · Heart Rhythm · doi:10.1016/j.hrthm.2012.12.001 · Cited by 253
Kutyifa, V., Moss, A. J., Klein, H., Biton, Y., McNitt, S., MacKecknie, B., Zareba, W., & Goldenberg, I. (2015) · Circulation · doi:10.1161/circulationaha.115.015677 · Cited by 243
Chan, P., Wong, C., Poh, Y. C., Pun, L., Leung, W. W., Wong, Y., Wong, M. M., Poh, M., Chu, D. W., & Siu, C. (2016) · Journal of the American Heart Association · doi:10.1161/jaha.116.003428 · Cited by 240
McConnell, M. V., Shcherbina, A., Pavlovic, A., Homburger, J. R., Goldfeder, R. L., Waggot, D., Cho, M. K., Rosenberger, M. E., Haskell, W. L., Myers, J., et al. (2017) · JAMA Cardiology · doi:10.1001/jamacardio.2016.4395 · Cited by 239
Inan, O. T., Baran Pouyan, M., Javaid, A. Q., Dowling, S., Etemadi, M., Dorier, A., Heller, J. A., Bicen, A. O., Roy, S., De Marco, T., et al. (2018) · Circulation: Heart Failure · doi:10.1161/circheartfailure.117.004313 · Cited by 207
ROTHMAN, S. A., LAUGHLIN, J. C., SELTZER, J., WALIA, J. S., BAMAN, R. I., SIOUFFI, S. Y., SANGRIGOLI, R. M., & KOWEY, P. R. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00729.x · Cited by 194 · cited 12×
“75%) among patients with symptoms suggestive of significant cardiac arrhythmia and a nondiagnostic result from 24-h Holter [3].”
BackgroundInfluentialAdedinsewo, D., Carter, R. E., Attia, Z., Johnson, P., Kashou, A. H., Dugan, J. L., Albus, M., Sheele, J. M., Bellolio, F., Friedman, P. A., et al. (2020) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.120.008437 · Cited by 169
Self-citationInfluence of skin type and wavelength on light wave reflectance
Fallow, B. A., Tarumi, T., & Tanaka, H. (2013) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-013-9436-7 · Cited by 162 · cited 1×
“Furthermore, darker skin pigmentation and ambulation are factors that have been shown to reduce the accuracy of PPG-based devices, due to the modulation of the light wavelength by melanin and decreased device-to-skin contact [23,37].”
BackgroundKuwabara, M., Harada, K., Hishiki, Y., & Kario, K. (2019) · The Journal of Clinical Hypertension · doi:10.1111/jch.13499 · Cited by 140 · cited 1×
“showed only minimal deviation from manual standard measurements [76].”
BackgroundGawałko, M., Duncker, D., Manninger, M., van der Velden, R. M. J., Hermans, A. N. L., Verhaert, D. V. M., Pison, L., Pisters, R., Hemels, M., Sultan, A., et al. (2021) · EP Europace · doi:10.1093/europace/euab050 · Cited by 106
Self-citationYao, X., McCoy, R. G., Friedman, P. A., Shah, N. D., Barry, B. A., Behnken, E. M., Inselman, J. W., Attia, Z. I., & Noseworthy, P. A. (2020) · American Heart Journal · doi:10.1016/j.ahj.2019.10.007 · Cited by 98 · cited 1×
“When assessed in a pragmatic randomized controlled trial, the AI ECG algorithm, serving as a clinical decision support tool, significantly improved the diagnosis of low EF in 22,641 patients managed in routine primary care settings [121,122].”
MethodSelf-citationHigh-Throughput, Contact-Free Detection of Atrial Fibrillation From Video With Deep Learning
Yan, B. P., Lai, W. H. S., Chan, C. K. Y., Au, A. C. K., Freedman, B., Poh, Y. C., & Poh, M.-Z. (2020) · JAMA Cardiology · doi:10.1001/jamacardio.2019.4004 · Cited by 94
Papini, G. B., Fonseca, P., van Gilst, M. M., Bergmans, J. W. M., Vullings, R., & Overeem, S. (2020) · Scientific Reports · doi:10.1038/s41598-020-69935-7 · Cited by 90 · cited 1×
“61; estimation error = 3 ± 10 events/h) [110].”
Athilingam, P., Labrador, M. A., Remo, E. F. J., Mack, L., San Juan, A. B., & Elliott, A. F. (2016) · Applied Nursing Research · doi:10.1016/j.apnr.2016.07.001 · Cited by 78
Novel Use of Apple Watch 4 to Obtain 3-Lead Electrocardiogram and Detect Cardiac Ischemia
Avila, C. O. (2019) · The Permanente Journal · doi:10.7812/tpp/19-025 · Cited by 76 · cited 1×
“In a small case series of 2 patients that presented with an STEMI, an Apple Watch 4 (Apple, Cupertino, CA) was used to create a 3-lead ECG [46] as an alternative diagnostic”
MethodHeckbert, S. R., Austin, T. R., Jensen, P. N., Floyd, J. S., Psaty, B. M., Soliman, E. Z., & Kronmal, R. A. (2018) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2018.07.027 · Cited by 72 · cited 1×
“Conversely, the use of the Zio XT Patch in a community-based sample of older individuals led to relatively low detection rates of atrioventricular block (2nd degree Mobitz II or 3rd degree; 3%) and pauses of more than three seconds (3%) [13].”
MethodSchreiber, D., Sattar, A., Drigalla, D., & Higgins, S. (2014) · Western Journal of Emergency Medicine · doi:10.5811/westjem.2013.11.18973 · Cited by 65
Castelletti, S., Dagradi, F., Goulene, K., Danza, A. I., Baldi, E., Stramba-Badiale, M., & Schwartz, P. J. (2018) · International Journal of Cardiology · doi:10.1016/j.ijcard.2018.03.097 · Cited by 63 · cited 7×
“Exercise has been associated with arrhythmic events in LQTS patients, especially those with type 1 LQTS [103].”
MethodResultInfluentialOLSON, J. A., FOUTS, A. M., PADANILAM, B. J., & PRYSTOWSKY, E. N. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00779.x · Cited by 59 · cited 1×
“The MCOT system had a particular role in the detection of asymptomatic clinically significant arrhythmias [4], highlighting the benefits of continuous cardiac monitoring in at-risk patients.”
BackgroundWerhahn, S. M., Dathe, H., Rottmann, T., Franke, T., Vahdat, D., Hasenfuß, G., & Seidler, T. (2019) · ESC Heart Failure · doi:10.1002/ehf2.12425 · Cited by 59
Role of wearable rhythm recordings in clinical decision making—The wEHRAbles project
Manninger, M., Kosiuk, J., Zweiker, D., Njeim, M., Antolic, B., Kircanski, B., Larsen, J. M., Svennberg, E., Vanduynhoven, P., & Duncker, D. (2020) · Clinical Cardiology · doi:10.1002/clc.23404 · Cited by 50 · cited 1×
“One concern among doctors when using wearables and new technologies is data overload.[141] With the expected amount of data, AI can help with the selection and presorting and make the evaluation more efficient.”
BackgroundSelf-citationHan, J. K., Al-Khatib, S. M., & Albert, C. M. (2021) · Cardiovascular Digital Health Journal · doi:10.1016/j.cvdhj.2020.12.001 · Cited by 29
Reed, M. J., Grubb, N. R., Lang, C. C., Gray, A. J., Simpson, K., MacRaild, A., & Weir, C. J. (2018) · Emergency Medicine Journal · doi:10.1136/emermed-2018-207570 · Cited by 28 · cited 1×
“Similar application in patients with unexplained syncope who presented to the emergency department resulted in a diagnostic yield of 27.9% [12].”
BackgroundInfluential
Cited by
Dhingra, L. S., Aminorroaya, A., Oikonomou, E. K., Nargesi, A. A., Wilson, F. P., Krumholz, H. M., & Khera, R. (2023) · JAMA Network Open · doi:10.1001/jamanetworkopen.2023.16634 · Cited by 158
Lee, S., Chu, Y., Ryu, J., Park, Y. J., Yang, S., & Koh, S. B. (2022) · Yonsei Medical Journal · doi:10.3349/ymj.2022.63.s93 · Cited by 88
Challenges and Potential of Using Digital Biomarkers in Healthcare and Clinical Trials
Lieberwirth, J. K., Mittermaier, M., & Stern, A. D. (2026) · Communications Medicine · doi:10.1038/s43856-026-01450-8 · Cited by 13
Metadata
- Authors
- Duncker, D., Ding, W. Y., Etheridge, S., Noseworthy, P. A., Veltmann, C., Yao, X., Bunch, T. J., & Gupta, D.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2021-04-05
- Volume
- 21
- Issue
- 7
- Pages
- 2539
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W3144735448
- Cited by
- 128
- References
- 49
- FWCI
- 6.02
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.