Estimating Risk of Cancer Associated With Radiation Exposure From 64-Slice Computed Tomography Coronary Angiography
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
CONTEXT: Computed tomography coronary angiography (CTCA) has become a common diagnostic test, yet there are little data on its associated cancer risk. The recent Biological Effects of Ionizing Radiation (BEIR) VII Phase 2 report provides a framework for estimating lifetime attributable risk (LAR) of cancer incidence associated with radiation exposure from a CTCA study, using the most current data available on health effects of radiation. OBJECTIVES: To determine the LAR of cancer incidence associated with radiation exposure from a 64-slice CTCA study and to evaluate the influence of age, sex, and scan protocol on cancer risk. DESIGN, SETTING, AND PATIENTS: Organ doses from 64-slice CTCA to standardized phantom (computational model) male and female patients were estimated using Monte Carlo simulation methods, using standard spiral CT protocols. Age- and sex-specific LARs of individual cancers were estimated using the approach of BEIR VII and summed to obtain whole-body LARs. MAIN OUTCOME MEASURES: Whole-body and organ LARs of cancer incidence. RESULTS: Organ doses ranged from 42 to 91 mSv for the lungs and 50 to 80 mSv for the female breast. Lifetime cancer risk estimates for standard cardiac scans varied from 1 in 143 for a 20-year-old woman to 1 in 3261 for an 80-year-old man. Use of simulated electrocardiographically controlled tube current modulation (ECTCM) decreased these risk estimates to 1 in 219 and 1 in 5017, respectively. Estimated cancer risks using ECTCM for a 60-year-old woman and a 60-year-old man were 1 in 715 and 1 in 1911, respectively. A combined scan of the heart and aorta had higher LARs, up to 1 in 114 for a 20-year-old woman. The highest organ LARs were for lung cancer and, in younger women, breast cancer. CONCLUSIONS: These estimates derived from our simulation models suggest that use of 64-slice CTCA is associated with a nonnegligible LAR of cancer. This risk varies markedly and is considerably greater for women, younger patients, and for combined cardiac and aortic scans.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recommendations of the International Commission on Radiological Protection
(1961) · Postgraduate Medical Journal · doi:10.1136/pgmj.37.425.168-b · Cited by 5,862
Writing Group Members, Thom, T., Haase, N., Rosamond, W., Howard, V. J., Rumsfeld, J., Manolio, T., Zheng, Z.-J., Flegal, K., O’Donnell, C., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.171600 · Cited by 3,451
Health Risks from Exposure to Low Levels of Ionizing Radiation:: BEIR VII Phase 2
Earth, D. O. (2006) · CERN Document Server (European Organization for Nuclear Research) · Cited by 2,190
Budoff, M. J., Achenbach, S., Blumenthal, R. S., Carr, J. J., Goldin, J. G., Greenland, P., Guerci, A. D., Lima, J. A. C., Rader, D. J., Rubin, G. D., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178458 · Cited by 1,398
Scanlon, P. J., Faxon, D. P., Audet, A.-M., Carabello, B., Dehmer, G. J., Eagle, K. A., Legako, R. D., Leon, D. F., Murray, J. A., Nissen, S. E., et al. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00126-6 · Cited by 1,123
Recommendations of the International Commission on Radiological Protection Publication 60
Icrp (1991) · Annals of the ICRP · Cited by 835
Cancer Incidence in Atomic Bomb Survivors. Part II: Solid Tumors, 1958-1987
Thompson, D. E., Mabuchi, K., Ron, E., Soda, M., Tokunaga, M., Ochikubo, S., Sugimoto, S., Ikeda, T., Terasaki, M., Izumi, S., et al. (1994) · Radiation Research · doi:10.2307/3578892 · Cited by 779
Hausleiter, J., Meyer, T., Hadamitzky, M., Huber, E., Zankl, M., Martinoff, S., Kastrati, A., & Schömig, A. (2006) · Circulation · doi:10.1161/circulationaha.105.602490 · Cited by 705
Jakobs, T. F., Becker, C. R., Ohnesorge, B., Flohr, T., Suess, C., Schoepf, U. J., & Reiser, M. F. (2002) · European Radiology · doi:10.1007/s00330-001-1278-x · Cited by 615
Cited by
2014 ESC Guidelines on the diagnosis and management of acute pulmonary embolism
Authors/Task Force Members, Konstantinides, S. V., Torbicki, A., Agnelli, G., Danchin, N., Fitzmaurice, D., Galiè, N., Gibbs, J. S. R., Huisman, M. V., Humbert, M., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu283 · Cited by 3,128
Smith-Bindman, R. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.427 · Cited by 2,464
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e3182776f83 · Cited by 2,410
Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog
Mettler, F. A., Huda, W., Yoshizumi, T. T., & Mahesh, M. (2008) · Radiology · doi:10.1148/radiol.2481071451 · Cited by 2,008
Projected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007
Berrington de González, A. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.440 · Cited by 1,888
Diagnostic Performance of Coronary Angiography by 64-Row CT
Miller, J. M., Rochitte, C. E., Dewey, M., Arbab-Zadeh, A., Niinuma, H., Gottlieb, I., Paul, N., Clouse, M. E., Shapiro, E. P., Hoe, J., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0806576 · Cited by 1,815
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.07.013 · Cited by 1,555
Exposure to Low-Dose Ionizing Radiation from Medical Imaging Procedures
Fazel, R., Krumholz, H. M., Wang, Y., Ross, J. S., Chen, J., Ting, H. H., Shah, N. D., Nasir, K., Einstein, A. J., & Nallamothu, B. K. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0901249 · Cited by 1,338
Self-citationBenefits and Harms of CT Screening for Lung Cancer: A Systematic Review
Bach, P. B., Mirkin, J. N., Oliver, T. K., Azzoli, C. G., Berry, D. A., Brawley, O. W., Byers, T., Colditz, G. A., Gould, M. K., Jett, J. R., et al. (2012) · JAMA · doi:10.1001/jama.2012.5521 · Cited by 1,244
Diagnostic Accuracy of 64-Slice Computed Tomography Coronary Angiography
Meijboom, W. B., Meijs, M. F. L., Schuijf, J. D., Cramer, M. J., Mollet, N. R., van Mieghem, C. A. G., Nieman, K., van Werkhoven, J. M., Pundziute, G., Weustink, A. C., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.08.058 · Cited by 1,239
Abbara, S., Blanke, P., Maroules, C. D., Cheezum, M., Choi, A. D., Han, B. K., Marwan, M., Naoum, C., Norgaard, B. L., Rubinshtein, R., et al. (2016) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2016.10.002 · Cited by 1,095
Estimated Radiation Dose Associated With Cardiac CT Angiography
Hausleiter, J. (2009) · JAMA · doi:10.1001/jama.2009.54 · Cited by 1,000
Sodickson, A., Baeyens, P. F., Andriole, K. P., Prevedello, L. M., Nawfel, R. D., Hanson, R., & Khorasani, R. (2009) · Radiology · doi:10.1148/radiol.2511081296 · Cited by 990
Cancer risks from diagnostic radiology
HALL, E. J., & BRENNER, D. J. (2008) · The British Journal of Radiology · doi:10.1259/bjr/01948454 · Cited by 915
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e318277d6a0 · Cited by 845
Whitlock, E. P., Lin, J. S., Liles, E., Beil, T. L., & Fu, R. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-9-200811040-00245 · Cited by 845
Radiation Dose to Patients From Cardiac Diagnostic Imaging
Einstein, A. J., Moser, K. W., Thompson, R. C., Cerqueira, M. D., & Henzlova, M. J. (2007) · Circulation · doi:10.1161/circulationaha.107.688101 · Cited by 806
Self-citationAmsterdam, E. A., Kirk, J. D., Bluemke, D. A., Diercks, D., Farkouh, M. E., Garvey, J. L., Kontos, M. C., McCord, J., Miller, T. D., Morise, A., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3181ec61df · Cited by 609
Achenbach, S., Marwan, M., Ropers, D., Schepis, T., Pflederer, T., Anders, K., Kuettner, A., Daniel, W. G., Uder, M., & Lell, M. M. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehp470 · Cited by 585
Goldstein, J. A., Chinnaiyan, K. M., Abidov, A., Achenbach, S., Berman, D. S., Hayes, S. W., Hoffmann, U., Lesser, J. R., Mikati, I. A., O'Neil, B. J., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.03.068 · Cited by 583
Abbara, S., Arbab-Zadeh, A., Callister, T. Q., Desai, M. Y., Mamuya, W., Thomson, L., & Weigold, W. G. (2009) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2009.03.004 · Cited by 580
The Measurement, Reporting, and Management of Radiation Dose in CT
McCollough, C., Cody, D., Edyvean, S., Geise, R., Gould, B., Keat, N., Huda, W., Judy, P., Kalender, W., McNitt-Gray, M., et al. (2008) · doi:10.37206/97 · Cited by 569
Initial evaluation of coronary images from 320-detector row computed tomography
Rybicki, F. J., Otero, H. J., Steigner, M. L., Vorobiof, G., Nallamshetty, L., Mitsouras, D., Ersoy, H., Mather, R. T., Judy, P. F., Cai, T., et al. (2008) · The International Journal of Cardiovascular Imaging · doi:10.1007/s10554-008-9308-2 · Cited by 563
Schroeder, S., Achenbach, S., Bengel, F., Burgstahler, C., Cademartiri, F., de Feyter, P., George, R., Kaufmann, P., Kopp, A. F., Knuuti, J., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehm544 · Cited by 554
Earls, J. P., Berman, E. L., Urban, B. A., Curry, C. A., Lane, J. L., Jennings, R. S., McCulloch, C. C., Hsieh, J., & Londt, J. H. (2008) · Radiology · doi:10.1148/radiol.2463070989 · Cited by 543
Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating
Husmann, L., Valenta, I., Gaemperli, O., Adda, O., Treyer, V., Wyss, C. A., Veit-Haibach, P., Tatsugami, F., von Schulthess, G. K., & Kaufmann, P. A. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm613 · Cited by 530
Whole-Body PET/CT Scanning: Estimation of Radiation Dose and Cancer Risk
Huang, B., Law, M. W.-M., & Khong, P.-L. (2009) · Radiology · doi:10.1148/radiol.2511081300 · Cited by 522
Converting Dose-Length Product to Effective Dose at CT
Huda, W., Ogden, K. M., & Khorasani, M. R. (2008) · Radiology · doi:10.1148/radiol.2483071964 · Cited by 513
SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT
Halliburton, S. S., Abbara, S., Chen, M. Y., Gentry, R., Mahesh, M., Raff, G. L., Shaw, L. J., & Hausleiter, J. (2011) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2011.06.001 · Cited by 491
Gerber, T. C., Carr, J. J., Arai, A. E., Dixon, R. L., Ferrari, V. A., Gomes, A. S., Heller, G. V., McCollough, C. H., McNitt-Gray, M. F., Mettler, F. A., et al. (2009) · Circulation · doi:10.1161/circulationaha.108.191650 · Cited by 487
Mowatt, G., Cook, J. A., Hillis, G. S., Walker, S., Fraser, C., Jia, X., & Waugh, N. (2008) · Heart · doi:10.1136/hrt.2008.145292 · Cited by 484
Marin, D., Nelson, R. C., Schindera, S. T., Richard, S., Youngblood, R. S., Yoshizumi, T. T., & Samei, E. (2010) · Radiology · doi:10.1148/radiol.09090094 · Cited by 484
Kilner, P. J., Geva, T., Kaemmerer, H., Trindade, P. T., Schwitter, J., & Webb, G. D. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehp586 · Cited by 429
ICRP Publication 120: Radiological Protection in Cardiology
Cousins, C., Miller, D. L., Bernardi, G., Rehani, M. M., Schofield, P., Vañó, E., Einstein, A. J., Geiger, B., Heintz, P., Padovani, R., et al. (2013) · Annals of the ICRP · doi:10.1016/j.icrp.2012.09.001 · Cited by 428
Self-citationDetterbeck, F. C., Mazzone, P. J., Naidich, D. P., & Bach, P. B. (2013) · Chest · doi:10.1378/chest.12-2350 · Cited by 411
Radiation dose reduction in computed tomography: techniques and future perspective
Yu, L., Liu, X., Leng, S., Kofler, J. M., Ramirez-Giraldo, J. C., Qu, M., Christner, J., Fletcher, J. G., & McCollough, C. H. (2009) · Imaging in Medicine · doi:10.2217/iim.09.5 · Cited by 395
Shuman, W. P., Branch, K. R., May, J. M., Mitsumori, L. M., Lockhart, D. W., Dubinsky, T. J., Warren, B. H., & Caldwell, J. H. (2008) · Radiology · doi:10.1148/radiol.2482072192 · Cited by 366
Abdulla, J., Abildstrom, S. Z., Gotzsche, O., Christensen, E., Kober, L., & Torp-Pedersen, C. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm466 · Cited by 357
Radiation Risks of Medical Imaging: Separating Fact from Fantasy
Hendee, W. R., & O’Connor, M. K. (2012) · Radiology · doi:10.1148/radiol.12112678 · Cited by 354
Liu, Y., Ma, J., Fan, Y., & Liang, Z. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/23/7923 · Cited by 335
Computed tomography and patient risk: Facts, perceptions and uncertainties
Power, S. P., Moloney, F., Twomey, M., James, K., O’Connor, O. J., & Maher, M. M. (2016) · World Journal of Radiology · doi:10.4329/wjr.v8.i12.902 · Cited by 335
Dewey, M., Zimmermann, E., Deissenrieder, F., Laule, M., Dübel, H.-P., Schlattmann, P., Knebel, F., Rutsch, W., & Hamm, B. (2009) · Circulation · doi:10.1161/circulationaha.109.859280 · Cited by 328
Choi, E.-K., Choi, S. I., Rivera, J. J., Nasir, K., Chang, S.-A., Chun, E. J., Kim, H.-K., Choi, D.-J., Blumenthal, R. S., & Chang, H.-J. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.086 · Cited by 324
Gottlieb, I., Miller, J. M., Arbab-Zadeh, A., Dewey, M., Clouse, M. E., Sara, L., Niinuma, H., Bush, D. E., Paul, N., Vavere, A. L., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.07.072 · Cited by 309
Pulmonary embolism in pregnancy
Bourjeily, G., Paidas, M., Khalil, H., Rosene-Montella, K., & Rodger, M. (2010) · The Lancet · doi:10.1016/s0140-6736(09)60996-x · Cited by 306
Coronary Computed Tomography Angiography From Clinical Uses to Emerging Technologies
Abdelrahman, K. M., Chen, M. Y., Dey, A. K., Virmani, R., Finn, A. V., Khamis, R. Y., Choi, A. D., Min, J. K., Williams, M. C., Buckler, A. J., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.06.076 · Cited by 297
Mitchell, A. M., Jones, A. E., Tumlin, J. A., & Kline, J. A. (2010) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.05200709 · Cited by 294
Sparse-view x-ray CT reconstruction via total generalized variation regularization
Niu, S., Gao, Y., Bian, Z., Huang, J., Chen, W., Yu, G., Liang, Z., & Ma, J. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/12/2997 · Cited by 291
Moscariello, A., Takx, R. A. P., Schoepf, U. J., Renker, M., Zwerner, P. L., O’Brien, T. X., Allmendinger, T., Vogt, S., Schmidt, B., Savino, G., et al. (2011) · European Radiology · doi:10.1007/s00330-011-2164-9 · Cited by 276
Schuetz, G. M., Zacharopoulou, N. M., Schlattmann, P., & Dewey, M. (2010) · Annals of Internal Medicine · doi:10.7326/0003-4819-152-3-201002020-00008 · Cited by 265
Griffey, R. T., & Sodickson, A. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.08.1351 · Cited by 258
High-pitch spiral acquisition: A new scan mode for coronary CT angiography
Achenbach, S., Marwan, M., Schepis, T., Pflederer, T., Bruder, H., Allmendinger, T., Petersilka, M., Anders, K., Lell, M., Kuettner, A., et al. (2009) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2009.02.008 · Cited by 258
Ma, J., Huang, J., Feng, Q., Zhang, H., Lu, H., Liang, Z., & Chen, W. (2011) · Medical Physics · doi:10.1118/1.3638125 · Cited by 249
Mieres, J. H., Gulati, M., Bairey Merz, N., Berman, D. S., Gerber, T. C., Hayes, S. N., Kramer, C. M., Min, J. K., Newby, L. K., Nixon, J. V. (., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000061 · Cited by 244
Monoclonal B-cell lymphocytosis (MBL): biology, natural history and clinical management
Shanafelt, T. D., Ghia, P., Lanasa, M. C., Landgren, O., & Rawstron, A. C. (2010) · Leukemia · doi:10.1038/leu.2009.287 · Cited by 227
Normal Stress-Only Versus Standard Stress/Rest Myocardial Perfusion Imaging
Chang, S. M., Nabi, F., Xu, J., Raza, U., & Mahmarian, J. J. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.09.022 · Cited by 220
Han, B. K., Rigsby, C. K., Hlavacek, A., Leipsic, J., Nicol, E. D., Siegel, M. J., Bardo, D., Abbara, S., Ghoshhajra, B., Lesser, J. R., et al. (2015) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2015.07.004 · Cited by 211
Halpern, E. J. (2009) · Radiology · doi:10.1148/radiol.2522082335 · Cited by 197
“CT imaging, and coronary CT in particular, has been criticized as an important source of radiation exposure to the population (39,40).”
BackgroundNoninvasive Evaluation With Multislice Computed Tomography in Suspected Acute Coronary Syndrome
Henneman, M. M., Schuijf, J. D., Pundziute, G., van Werkhoven, J. M., van der Wall, E. E., Jukema, J. W., & Bax, J. J. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.04.012 · Cited by 189
A review of patient dose and optimisation methods in adult and paediatric CT scanning
Dougeni, E., Faulkner, K., & Panayiotakis, G. (2012) · European Journal of Radiology · doi:10.1016/j.ejrad.2011.05.025 · Cited by 185
“[90] 9–23 male (Monte Carlo)”
Eisenberg, M. J., Afilalo, J., Lawler, P. R., Abrahamowicz, M., Richard, H., & Pilote, L. (2011) · Canadian Medical Association Journal · doi:10.1503/cmaj.100463 · Cited by 185
Diagnosis of Pulmonary Embolism During Pregnancy: A Multicenter Prospective Management Outcome Study
Righini, M., Robert-Ebadi, H., Elias, A., Sanchez, O., Le Moigne, E., Schmidt, J., Le Gall, C., Cornuz, J., Aujesky, D., Roy, P.-M., et al. (2018) · Annals of Internal Medicine · doi:10.7326/m18-1670 · Cited by 181
“Mean heart rate (SD), beats/min 91 (17)”
BackgroundCT Scans and Cancer Risks: A Systematic Review and Dose-response Meta-analysis
Cao, C.-F., Ma, K.-L., Shan, H., Liu, T.-F., Zhao, S.-Q., Wan, Y., Jun-Zhang, & Wang, H.-Q. (2022) · BMC Cancer · doi:10.1186/s12885-022-10310-2 · Cited by 176
Maruyama, T., Takada, M., Hasuike, T., Yoshikawa, A., Namimatsu, E., & Yoshizumi, T. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.07.048 · Cited by 175
Westphalen, A. C., Hsia, R. Y., Maselli, J. H., Wang, R., & Gonzales, R. (2011) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2011.01103.x · Cited by 175
Einstein, A. J., Weiner, S. D., Bernheim, A., Kulon, M., Bokhari, S., Johnson, L. L., Moses, J. W., & Balter, S. (2010) · JAMA · doi:10.1001/jama.2010.1664 · Cited by 164
“5 (6-31) [1-166] 16 (6-30) [1-159] 15 (6-29) [1-193] .”
InfluentialSelf-citationHollander, J. E., Chang, A. M., Shofer, F. S., McCusker, C. M., Baxt, W. G., & Litt, H. I. (2009) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2008.09.025 · Cited by 164
“9) Male (%) 112 (40) 140 (49) 252 (44) Race (%) Black 191 (67) 169 (59) 360 (68) White 65 (24) 75 (26) 140 (26) Asian 9 (3) 7 (2) 16 (3) Hispanic 3 (1) 6 (2) 9 (2) Other/unknown 15 (5) 28 (10) 43 (8) Cardiac risk factors (%)* Hypertension 137 (48) 114 (40) 251 (44) Hypercholesterolemia 53 (19) 55 (19) 108 (19) Family…”
Chen, M. Y., Shanbhag, S. M., & Arai, A. E. (2013) · Radiology · doi:10.1148/radiol.13122621 · Cited by 164
Sree, S. V. (2011) · World Journal of Clinical Oncology · doi:10.5306/wjco.v2.i4.171 · Cited by 158
Hong, J. C., Blankstein, R., Shaw, L. J., Padula, W. V., Arrieta, A., Fialkow, J. A., Blumenthal, R. S., Blaha, M. J., Krumholz, H. M., & Nasir, K. (2017) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2017.04.014 · Cited by 101
NATIONAL DIAGNOSTIC REFERENCE LEVEL INITIATIVE FOR COMPUTED TOMOGRAPHY EXAMINATIONS IN KENYA
Korir, G. K., Wambani, J. S., Korir, I. K., Tries, M. A., & Boen, P. K. (2015) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncv020 · Cited by 52
Catalysis in abiotic structured media: an approach to selective synthesis of biopolymers
Monnard, P.-A. (2005) · Cellular and Molecular Life Sciences · doi:10.1007/s00018-004-4342-2 · Cited by 20
Metadata
- Authors
- Einstein, A. J., Henzlova, M. J., & Rajagopalan, S.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2007-07-18
- Volume
- 298
- Issue
- 3
- Pages
- 317
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2095728038
- Cited by
- 1,410
- References
- 23
- FWCI
- 116.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.