The DOI matches its Crossref record; 77 of the 77 references it cites were found in a registry or an index.
4D flow MRI
Open accessAbstract
Traditionally, magnetic resonance imaging (MRI) of flow using phase contrast (PC) methods is accomplished using methods that resolve single‐directional flow in two spatial dimensions (2D) of an individual slice. More recently, three‐dimensional (3D) spatial encoding combined with three‐directional velocity‐encoded phase contrast MRI (here termed 4D flow MRI) has drawn increased attention. 4D flow MRI offers the ability to measure and to visualize the temporal evolution of complex blood flow patterns within an acquired 3D volume. Various methodological improvements permit the acquisition of 4D flow MRI data encompassing individual vascular structures and entire vascular territories such as the heart, the adjacent aorta, the carotid arteries, abdominal, or peripheral vessels within reasonable scan times. To subsequently analyze the flow data by quantitative means and visualization of complex, three‐directional blood flow patterns, various tools have been proposed. This review intends to introduce currently used 4D flow MRI methods, including Cartesian and radial data acquisition, approaches for accelerated data acquisition, cardiac gating, and respiration control. Based on these developments, an overview is provided over the potential this new imaging technique has in different parts of the body from the head to the peripheral arteries. J. Magn. Reson. Imaging 2012;36:1015–1036. © 2012 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments
Carr, H. Y., & Purcell, E. M. (1954) · Physical Review · doi:10.1103/physrev.94.630 · Cited by 6,466
Hemodynamic shear stress and its role in atherosclerosis
Malek, A. M. (1999) · JAMA · doi:10.1001/jama.282.21.2035 · Cited by 3,650
Kircher, B. J., Himelman, R. B., & Schiller, N. B. (1990) · The American Journal of Cardiology · doi:10.1016/0002-9149(90)90711-9 · Cited by 1,027
Atherosclerotic Disease of the Aortic Arch and the Risk of Ischemic Stroke
Amarenco, P., Cohen, A., Tzourio, C., Bertrand, B., Hommel, M., Besson, G., Chauvel, C., Touboul, P.-J., & Bousser, M.-G. (1994) · New England Journal of Medicine · doi:10.1056/nejm199412013312202 · Cited by 1,008
Atherosclerotic Lesion Size and Vulnerability Are Determined by Patterns of Fluid Shear Stress
Cheng, C., Tempel, D., van Haperen, R., van der Baan, A., Grosveld, F., Daemen, M. J. A. P., Krams, R., & de Crom, R. (2006) · Circulation · doi:10.1161/circulationaha.105.590018 · Cited by 1,000
Carabello, B. A., & Paulus, W. J. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60211-7 · Cited by 818
Adaptive technique for high-definition MR imaging of moving structures.
Ehman, R. L., & Felmlee, J. P. (1989) · Radiology · doi:10.1148/radiology.173.1.2781017 · Cited by 801
k‐t BLAST and k‐t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations
Tsao, J., Boesiger, P., & Pruessmann, K. P. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10611 · Cited by 794
A flow velocity zeugmatographic interlace for NMR imaging in humans
Moran, P. R. (1982) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(82)90170-9 · Cited by 745
Asymmetric redirection of flow through the heart
Kilner, P. J., Yang, G.-Z., Wilkes, A. J., Mohiaddin, R. H., Firmin, D. N., & Yacoub, M. H. (2000) · Nature · doi:10.1038/35008075 · Cited by 715
Blood Flow Imaging by Cine Magnetic Resonance
Nayler, G. L., Firmin, D. N., & Longmore, D. B. (1986) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198609000-00001 · Cited by 634
Phase contrast cine magnetic resonance imaging.
Pelc, N. J., Herfkens, R. J., Shimakawa, A. S., & Enzmann, D. R. (1991) · PubMed · Cited by 610
Kilner, P. J., Yang, G. Z., Mohiaddin, R. H., Firmin, D. N., & Longmore, D. B. (1993) · Circulation · doi:10.1161/01.cir.88.5.2235 · Cited by 592
Projection Reconstruction Techniques for Reduction of Motion Effects in MRI
Glover, G. H., & Pauly, J. M. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910280209 · Cited by 563
Concomitant gradient terms in phase contrast MR: Analysis and correction
Bernstein, M. A., Zhou, X. J., Polzin, J. A., King, K. F., Ganin, A., Pelc, N. J., & Glover, G. H. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390218 · Cited by 547
Measurement of Flow with NMR Imaging Using a Gradient Pulse and Phase Difference Technique
Bryant, D. J., Payne, J. A., Firmin, D. N., & Longmore, D. B. (1984) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198408000-00002 · Cited by 545
Boussel, L., Rayz, V., McCulloch, C., Martin, A., Acevedo-Bolton, G., Lawton, M., Higashida, R., Smith, W. S., Young, W. L., & Saloner, D. (2008) · Stroke · doi:10.1161/strokeaha.108.521617 · Cited by 535
Wang, Y., Riederer, S. J., & Ehman, R. L. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330517 · Cited by 491
Stalder, A. F., Russe, M. F., Frydrychowicz, A., Bock, J., Hennig, J., & Markl, M. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21778 · Cited by 474
Self-citationMarkl, M., Kilner, P. J., & Ebbers, T. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-7 · Cited by 463
Self-citationEncoding strategies for three‐direction phase‐contrast MR imaging of flow
Pelc, N. J., Bernstein, M. A., Shimakawa, A., & Glover, G. H. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010404 · Cited by 455
Three‐dimensional phase contrast angiography
Dumoulin, C. L., Souza, S. P., Walker, M. F., & Wagle, W. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910090117 · Cited by 432
Larson, A. C., White, R. D., Laub, G., McVeigh, E. R., Li, D., & Simonetti, O. P. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10664 · Cited by 419
Bicuspid Aortic Valve: Four-dimensional MR Evaluation of Ascending Aortic Systolic Flow Patterns
Hope, M. D., Hope, T. A., Meadows, A. K., Ordovas, K. G., Urbania, T. H., Alley, M. T., & Higgins, C. B. (2010) · Radiology · doi:10.1148/radiol.09091437 · Cited by 417
Self-citationWang, Y., Rossman, P. J., Grimm, R. C., Riederer, S. J., & Ehman, R. L. (1996) · Radiology · doi:10.1148/radiology.198.1.8539406 · Cited by 386
Direct Cardiac NMR Imaging of Heart Wall and Blood Flow Velocity
van Dijk, P. (1984) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198406000-00012 · Cited by 343
Bailes, D. R., Gilderdale, D. J., Bydder, G. M., Collins, A. G., & Firmin, D. N. (1985) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198507010-00039 · Cited by 313
Bailes, D. R., Gilderdale, D. J., Bydder, G. M., et al. (1985) · PubMed · Cited by 300
Aortic Atherosclerotic Disease and Stroke
Kronzon, I., & Tunick, P. A. (2006) · Circulation · doi:10.1161/circulationaha.105.593418 · Cited by 296
Kim, W. Y., Walker, P. G., Pedersen, E. M., Poulsen, J. K., Oyre, S., Houlind, K., & Yoganathan, A. P. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00141-l · Cited by 274
4D Flow CMR in Assessment of Valve-Related Ascending Aortic Disease
Hope, M. D., Hope, T. A., Crook, S. E. S., Ordovas, K. G., Urbania, T. H., Alley, M. T., & Higgins, C. B. (2011) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2011.05.004 · Cited by 273
Self-citationMarkl, M., Wegent, F., Zech, T., Bauer, S., Strecker, C., Schumacher, M., Weiller, C., Hennig, J., & Harloff, A. (2010) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.110.958504 · Cited by 232
Self-citationPulmonary Arterial Hypertension: Noninvasive Detection with Phase-Contrast MR Imaging
Sanz, J., Kuschnir, P., Rius, T., Salguero, R., Sulica, R., Einstein, A. J., Dellegrottaglie, S., Fuster, V., Rajagopalan, S., & Poon, M. (2007) · Radiology · doi:10.1148/radiol.2431060477 · Cited by 227
Renal artery stenosis: A common and important problem in patients with peripheral vascular disease
Missouris, C. G., Buckenham, T. M., Cappuccio, F. P., & MacGregor, G. A. (1994) · The American Journal of Medicine · doi:10.1016/0002-9343(94)90109-0 · Cited by 223
Flow Residence Time and Regions of Intraluminal Thrombus Deposition in Intracranial Aneurysms
Rayz, V. L., Boussel, L., Ge, L., Leach, J. R., Martin, A. J., Lawton, M. T., McCulloch, C., & Saloner, D. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-0065-8 · Cited by 219
Temporally resolved 3D phase‐contrast imaging
Wigström, L., Sjöqvist, L., & Wranne, B. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360521 · Cited by 219
Particle trace visualization of intracardiac flow using time-resolved 3D phase contrast MRI
Wigstr�m, L., Ebbers, T., Fyrenius, A., Karlsson, M. O., Engvall, J. E., Wranne, B., & Bolger, A. F. (1999) · Magnetic Resonance in Medicine · Cited by 200
Detection of sea-water motion by nuclear precession
Hahn, E. L. (1960) · Journal of Geophysical Research · doi:10.1029/jz065i002p00776 · Cited by 197
Westenberg, J. J. M., Roes, S. D., Ajmone Marsan, N., Binnendijk, N. M. J., Doornbos, J., Bax, J. J., Reiber, J. H. C., de Roos, A., & van der Geest, R. J. (2008) · Radiology · doi:10.1148/radiol.2492080146 · Cited by 190
Frydrychowicz, A., Stalder, A. F., Russe, M. F., Bock, J., Bauer, S., Harloff, A., Berger, A., Langer, M., Hennig, J., & Markl, M. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21790 · Cited by 180
Self-citationDetermination of wall shear stress in the aorta with the use of MR phase velocity mapping
Osinnski, J. N., Ku, D. N., Mukundan, S., Loth, F., & Pettigrew, R. I. (1995) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880050605 · Cited by 174
Agarwal, R., Brunelli, S. M., Williams, K., Mitchell, M. D., Feldman, H. I., & Umscheid, C. A. (2008) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfn593 · Cited by 174
Reproducibility of flow and wall shear stress analysis using flow‐sensitive four‐dimensional MRI
Markl, M., Wallis, W., & Harloff, A. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22519 · Cited by 170
Self-citationBammer, R., Hope, T. A., Aksoy, M., & Alley, M. T. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21109 · Cited by 169
Bock, J., Frydrychowicz, A., Stalder, A. F., Bley, T. A., Burkhardt, H., Hennig, J., & Markl, M. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22199 · Cited by 166
Self-citationClinical evaluation of aortic coarctation with 4D flow MR imaging
Hope, M. D., Meadows, A. K., Hope, T. A., Ordovas, K. G., Saloner, D., Reddy, G. P., Alley, M. T., & Higgins, C. B. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22083 · Cited by 166
Self-citationUribe, S. A., Beerbaum, P., Sørensen, T. S., Rasmusson, A. G., Razavi, R., & Schaeffter, T. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22090 · Cited by 154
Thomsen, H. S., Morcos, S. K., & Dawson, P. (2006) · Clinical Radiology · doi:10.1016/j.crad.2006.09.003 · Cited by 153
Dyverfeldt, P., Kvitting, J. E., Sigfridsson, A., et al. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21475 · Cited by 153
Improved SNR in phase contrast velocimetry with five‐point balanced flow encoding
Johnson, K. M., & Markl, M. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22202 · Cited by 150
Self-citationComplex Plaques in the Proximal Descending Aorta
Harloff, A., Simon, J., Brendecke, S. M., Assefa, D., Helbing, T., Frydrychowicz, A. P., Weber, J., Olschewski, M., Strecker, C., Hennig, J., et al. (2010) · Stroke · doi:10.1161/strokeaha.109.577775 · Cited by 146
Self-citationEstimation of global aortic pulse wave velocity by flow‐sensitive 4D MRI
Markl, M., Wallis, W., Brendecke, S. M., Simon, J., Frydrychowicz, A. P., & Harloff, A. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22353 · Cited by 144
Self-citationHarloff, A., Albrecht, F., Spreer, J., Stalder, A. F., Bock, J., Frydrychowicz, A. P., Schöllhorn, J. S., Hetzel, A., Schumacher, M. C., Hennig, J., et al. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21774 · Cited by 143
Self-citationden Reijer, P. M., Sallee, D., van der Velden, P., Zaaijer, E. R., Parks, W. J., Ramamurthy, S., Robbie, T. Q., Donati, G., Lamphier, C. K., Beekman, R. P., et al. (2010) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-12-4 · Cited by 137
Chai, P., & Mohiaddin, R. H. (2005) · Journal of Cardiovascular Magnetic Resonance · doi:10.1081/jcmr-200065639 · Cited by 133
Ebbers, T., Wigström, L., Bolger, A. F., Wranne, B., & Karlsson, M. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1468866 · Cited by 125
Nordmeyer, S., Riesenkampff, E., Crelier, G. R., Khasheei, A., Schnackenburg, B., Berger, F. F., & Kühne, T. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22280 · Cited by 122
Computation of flow pressure fields from magnetic resonance velocity mapping
Yang, G., Kilner, P. J., Wood, N. B., Underwood, S. R., & Firmin, D. N. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360404 · Cited by 122
4D-MR flow analysis in patients after repair for tetralogy of Fallot
Geiger, J., Markl, M., Jung, B. A., Grohmann, J., Stiller, B., Langer, M., & Arnold, R. (2011) · European Radiology · doi:10.1007/s00330-011-2108-4 · Cited by 114
Self-citationAortic Hemodynamics in Patients With and Without Repair of Aortic Coarctation
Frydrychowicz, A. P., Markl, M., Hirtler, D., Harloff, A., Schlensak, C., Geiger, J., Stiller, B., & Arnold, R. (2011) · Investigative Radiology · doi:10.1097/rli.0b013e3182034fc2 · Cited by 112
Self-citationKozerke, S., Hasenkam, J. M., Pedersen, E. M., & Boesiger, P. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1097 · Cited by 97
Self-citationNormal and Altered Three-dimensional Portal Venous Hemodynamics in Patients with Liver Cirrhosis
Stanković, Z. B., Csatari, Z., Deibert, P., Euringer, W., Blanke, P., Kreisel, W., Zadeh, Z. A., Kallfass, F., Langer, M., & Markl, M. (2012) · Radiology · doi:10.1148/radiol.11110127 · Cited by 91
Self-citationPost-stenotic aortic dilatation
Wilton, E., & Jahangiri, M. (2006) · Journal of Cardiothoracic Surgery · doi:10.1186/1749-8090-1-7 · Cited by 81
Lum, D. P., Johnson, K. M., Paul, R. K., Turk, A. S., Consigny, D. W., Grinde, J. R., Mistretta, C. A., & Grist, T. M. (2007) · Radiology · doi:10.1148/radiol.2453061946 · Cited by 75
Evaluation of Bicuspid Aortic Valve and Aortic Coarctation With 4D Flow Magnetic Resonance Imaging
Hope, M. D., Meadows, A. K., Hope, T. A., Ordovas, K. G., Reddy, G. P., Alley, M. T., & Higgins, C. B. (2008) · Circulation · doi:10.1161/circulationaha.107.760124 · Cited by 74
Self-citationSen, S., Hinderliter, A. L., Sen, P. K., Simmons, J., Beck, J. D., Offenbacher, S., Ohman, E. M., & Oppenheimer, S. M. (2007) · Circulation · doi:10.1161/circulationaha.106.671727 · Cited by 72
Frydrychowicz, A. P., Arnold, R., Hirtler, D., Schlensak, C., Stalder, A. F., Hennig, J., Langer, M., & Markl, M. (2008) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-10-30 · Cited by 72
Self-citationBogren, H. G., Mohiaddin, R. H., Kilner, P. J., Jiménez‐Borreguero, L. J., Yang, G. Z., & Firmin, D. N. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070504 · Cited by 71
Nogami, M., Ohno, Y., Koyama, H., Kono, A. K., Takenaka, D., Kataoka, T., Kawai, H., Kawamitsu, H., Onishi, Y., Matsumoto, K., et al. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21935 · Cited by 63
Frydrychowicz, A. P., Winterer, J. T., Zaitsev, M., Jung, B. A., Hennig, J., Langer, M., & Markl, M. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20900 · Cited by 63
Self-citationStanković, Z. B., Frydrychowicz, A. P., Csatari, Z., Panther, E., Deibert, P., Euringer, W., Kreisel, W., Russe, M. F., Bauer, S., Langer, M., et al. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22248 · Cited by 62
Self-citationBley, T. A., Johnson, K. M., François, C. J., Reeder, S. B., Schiebler, M. L., Landgraf, B. R., Consigny, D. W., Grist, T. M., & Wieben, O. E. (2011) · Radiology · doi:10.1148/radiol.11101175 · Cited by 58
Self-citationStadlbauer, A., van der Riet, W., Crelier, G. R., & Salomonowitz, E. K. (2009) · European Journal of Radiology · doi:10.1016/j.ejrad.2009.06.009 · Cited by 55
Retrograde Blood Flow in the Aortic Arch Determined by Transesophageal Doppler Ultrasound
Svedlund, S., Wetterholm, R., Volkmann, R., & Caidahl, K. (2008) · Cerebrovascular Diseases · doi:10.1159/000172630 · Cited by 39
Oyre, S., Wp, P., Ringgaard, S., Kozerke, S., Erlandsen, M., Boesiger, P., & Pedersen, E. M. (1998) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/s1078-5884(98)80244-x · Cited by 30
Self-citationTurk, A. S., Johnson, K. M., Lum, D. P., Niemann, D., Aagaard‐Kienitz, B., Consigny, D. W., Grinde, J. R., Turski, P. A., Haughton, V. M., & Mistretta, C. A. (2007) · PubMed Central · Cited by 25
Cited by
4D flow cardiovascular magnetic resonance consensus statement
Dyverfeldt, P., Bissell, M., Barker, A. J., Bolger, A. F., Carlhäll, C.-J., Ebbers, T., Francios, C. J., Frydrychowicz, A., Geiger, J., Giese, D., et al. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0174-5 · Cited by 877
Self-citationAI in Medical Imaging Informatics: Current Challenges and Future Directions
Panayides, A. S., Amini, A., Filipovic, N. D., Sharma, A., Tsaftaris, S. A., Young, A., Foran, D., Do, N., Golemati, S., Kurc, T., et al. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.2991043 · Cited by 713
Kissas, G., Yang, Y., Hwuang, E., Witschey, W. R., Detre, J. A., & Perdikaris, P. (2020) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2019.112623 · Cited by 647
Imaging Assessment of Tricuspid Regurgitation Severity
Hahn, R. T., Thomas, J. D., Khalique, O. K., Cavalcante, J. L., Praz, F., & Zoghbi, W. A. (2019) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2018.07.033 · Cited by 343
Aortic Dilatation in Patients With Bicuspid Aortic Valve
Wang, J., Deng, W., Lv, Q., Li, Y., Liu, T., & Xie, M. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.615175 · Cited by 332
Metadata
- Authors
- Markl, M., Frydrychowicz, A., Kozerke, S., Hope, M., & Wieben, O.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2012-10-22
- Volume
- 36
- Issue
- 5
- Pages
- 1015-1036
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2069444004
- Cited by
- 788
- References
- 77
- FWCI
- 23.59
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.