The DOI matches its Crossref record; 119 of the 119 references it cites were found in a registry or an index.
Photoacoustic microscopy
Open accessAbstract
Photoacoustic microscopy (PAM) is a hybrid in vivo imaging technique that acoustically detects optical contrast via the photoacoustic effect. Unlike pure optical microscopic techniques, PAM takes advantage of the weak acoustic scattering in tissue and thus breaks through the optical diffusion limit (∼1 mm in soft tissue). With its excellent scalability, PAM can provide high‐resolution images at desired maximum imaging depths up to a few millimeters. Compared with backscattering‐based confocal microscopy and optical coherence tomography, PAM provides absorption contrast instead of scattering contrast. Furthermore, PAM can image more molecules, endogenous or exogenous, at their absorbing wavelengths than fluorescence‐based methods, such as wide‐field, confocal, and multi‐photon microscopy. Most importantly, PAM can simultaneously image anatomical, functional, molecular, flow dynamic and metabolic contrasts in vivo. Focusing on state‐of‐the‐art developments in PAM, this Review discusses the key features of PAM implementations and their applications in biomedical studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hallmarks of Cancer: The Next Generation
Hanahan, D., & Weinberg, R. A. (2011) · Cell · doi:10.1016/j.cell.2011.02.013 · Cited by 66,590
Hanahan, D., & Weinberg, R. A. (2000) · Cell · doi:10.1016/s0092-8674(00)81683-9 · Cited by 29,219
Photoacoustic tomography: In vivo imaging from organelles to organs
Wang, L. V., & Hu, S. (2012) · Science · doi:10.1126/science.1216210 · Cited by 4,331 · cited 6×
“It has been shown that the maximum imaging depth of PAM is approximately proportional to its lateral resolution [3].”
BackgroundMethodInfluentialSelf-citationNanoparticles in Medicine: Therapeutic Applications and Developments
Zhang, L., Gu, F., Chan, J., Wang, A., Langer, R., & Farokhzad, O. (2008) · Clinical Pharmacology & Therapeutics · doi:10.1038/sj.clpt.6100400 · Cited by 2,657
Nanoparticle and targeted systems for cancer therapy
Brannon-Peppas, L., & Blanchette, J. O. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2004.02.014 · Cited by 2,334
Biomedical photoacoustic imaging
Beard, P. (2011) · Interface Focus · doi:10.1098/rsfs.2011.0028 · Cited by 2,205
UV-induced DNA damage and repair: a review
Sinha, R. P., & Häder, D.-P. (2002) · Photochemical & Photobiological Sciences · doi:10.1039/b201230h · Cited by 1,978 · cited 1×
“Nevertheless, the potential cell damage caused by overexposure to UV light, such as direct and indirect DNA breakage, need to be carefully controlled [85].”
BackgroundFunctional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging
Zhang, H. F., Maslov, K., Stoica, G., & Wang, L. V. (2006) · Nature Biotechnology · doi:10.1038/nbt1220 · Cited by 1,854
Self-citationWang, X., Pang, Y., Ku, G., Xie, X., Stoica, G., & Wang, L. V. (2003) · Nature Biotechnology · doi:10.1038/nbt839 · Cited by 1,700
Self-citationMultiscale photoacoustic microscopy and computed tomography
Wang, L. V. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.157 · Cited by 1,400
Self-citationThe Journal of Investigative Dermatology
Kanof, N. M. (1967) · Archives of Dermatology · doi:10.1001/archderm.1967.01610020042010 · Cited by 1,370
Universal back-projection algorithm for photoacoustic computed tomography
Xu, M., & Wang, L. V. (2005) · Physical Review E · doi:10.1103/physreve.71.016706 · Cited by 1,243
Self-citationBiomedical Optics, Principles and Imaging
Wang, L. V., Wu, H.-I., & Masters, B. R. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2976007 · Cited by 1,178
Self-citationChallenges in Development of Nanoparticle-Based Therapeutics
Desai, N. (2012) · The AAPS Journal · doi:10.1208/s12248-012-9339-4 · Cited by 1,173
Nuclear structure in cancer cells
Zink, D., Fischer, A. H., & Nickerson, J. A. (2004) · Nature Reviews Cancer · doi:10.1038/nrc1430 · Cited by 1,068
Kim, C., Favazza, C., & Wang, L. V. (2010) · Chemical Reviews · doi:10.1021/cr900266s · Cited by 807
Self-citationNew Technologies for Human Cancer Imaging
Frangioni, J. V. (2008) · Journal of Clinical Oncology · doi:10.1200/jco.2007.14.3065 · Cited by 800
Optical-resolution photoacoustic microscopy for in vivo imaging of single capillaries
Maslov, K., Zhang, H. F., Hu, S., & Wang, L. V. (2008) · Optics Letters · doi:10.1364/ol.33.000929 · Cited by 763
Self-citationGolden carbon nanotubes as multimodal photoacoustic and photothermal high-contrast molecular agents
Kim, J.-W., Galanzha, E. I., Shashkov, E. V., Moon, H.-M., & Zharov, V. P. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.231 · Cited by 710
Photoacoustic tomography and sensing in biomedicine
Li, C., & Wang, L. V. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/19/r01 · Cited by 669
Self-citationMultispectral opto-acoustic tomography of deep-seated fluorescent proteins in vivo
Razansky, D., Distel, M., Vinegoni, C., Ma, R., Perrimon, N., Köster, R. W., & Ntziachristos, V. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.98 · Cited by 644
Tutorial on Photoacoustic Microscopy and Computed Tomography
Wang, L. V. (2008) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2007.913398 · Cited by 607
Self-citationIn vivo magnetic enrichment and multiplex photoacoustic detection of circulating tumour cells
Galanzha, E. I., Shashkov, E. V., Kelly, T., Kim, J.-W., Yang, L., & Zharov, V. P. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.333 · Cited by 575
Photoacoustic ultrasound (PAUS)—Reconstruction tomography
Kruger, R. A., Liu, P., Fang, Y. “., & Appledorn, C. R. (1995) · Medical Physics · doi:10.1118/1.597429 · Cited by 572
Prospects of photoacoustic tomography
Wang, L. V. (2008) · Medical Physics · doi:10.1118/1.3013698 · Cited by 561
Self-citationMultifunctional nanoparticles as coupled contrast agents
Jin, Y., Jia, C., Huang, S.-W., O'Donnell, M., & Gao, X. (2010) · Nature Communications · doi:10.1038/ncomms1042 · Cited by 496
Laser optoacoustic imaging system for detection of breast cancer
Ermilov, S. A., Khamapirad, T., Conjusteau, A., Leonard, M. H., Lacewell, R., Mehta, K., Miller, T., & Oraevsky, A. A. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3086616 · Cited by 493
In Vivo Molecular Photoacoustic Tomography of Melanomas Targeted by Bioconjugated Gold Nanocages
Kim, C., Cho, E. C., Chen, J., Song, K. H., Au, L., Favazza, C., Zhang, Q., Cobley, C. M., Gao, F., Xia, Y., et al. (2010) · ACS Nano · doi:10.1021/nn100736c · Cited by 462
Self-citationSecond-generation optical-resolution photoacoustic microscopy with improved sensitivity and speed
Hu, S., Maslov, K., & Wang, L. V. (2011) · Optics Letters · doi:10.1364/ol.36.001134 · Cited by 429
Self-citationSimultaneous functional photoacoustic and ultrasonic endoscopy of internal organs in vivo
Yang, J.-M., Favazza, C., Chen, R., Yao, J., Cai, X., Maslov, K., Zhou, Q., Shung, K. K., & Wang, L. V. (2012) · Nature Medicine · doi:10.1038/nm.2823 · Cited by 429
Self-citationPhotoacoustic imaging and characterization of the microvasculature
Hu, S., & Wang, L. V. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3281673 · Cited by 427
Self-citationBiomedical Applications of Photoacoustic Imaging with Exogenous Contrast Agents
Luke, G. P., Yeager, D., & Emelianov, S. Y. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0449-4 · Cited by 418
In vivo dark-field reflection-mode photoacoustic microscopy
Maslov, K., Stoica, G., & Wang, L. V. (2005) · Optics Letters · doi:10.1364/ol.30.000625 · Cited by 413
Self-citationYang, X., Skrabalak, S. E., Li, Z.-Y., Xia, Y., & Wang, L. V. (2007) · Nano Letters · doi:10.1021/nl072349r · Cited by 407
Self-citationUltrahigh Sensitivity Carbon Nanotube Agents for Photoacoustic Molecular Imaging in Living Mice
Zerda, A. D. L., Liu, Z., Bodapati, S., Teed, R., Vaithilingam, S., Khuri-Yakub, B. T., Chen, X., Dai, H., & Gambhir, S. S. (2010) · Nano Letters · doi:10.1021/nl100890d · Cited by 396
Zhang, H. F., Maslov, K., Sivaramakrishnan, M., Stoica, G., & Wang, L. V. (2007) · Applied Physics Letters · doi:10.1063/1.2435697 · Cited by 380
Self-citationSong, K. H., Kim, C., Cobley, C. M., Xia, Y., & Wang, L. V. (2009) · Nano Letters · doi:10.1021/nl802746w · Cited by 377
Self-citationLi, M.-L., Oh, J.-T., Xie, X., Ku, G., Wang, W., Li, C., Lungu, G., Stoica, G., & Wang, L. V. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2007.913515 · Cited by 352
Self-citationLabel-free oxygen-metabolic photoacoustic microscopy in vivo
Yao, J., Maslov, K. I., Zhang, Y., Xia, Y., & Wang, L. V. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3594786 · Cited by 333
Self-citationBasics of Biomedical Ultrasound for Engineers
Azhari, H. (2010) · Wiley eBooks · doi:10.1002/9780470561478 · Cited by 319
Whole-body three-dimensional optoacoustic tomography system for small animals
Brecht, H.-P. F., Su, R., Fronheiser, M. P., Ermilov, S. A., Conjusteau, A., & Oraevsky, A. A. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3259361 · Cited by 304
Photoacoustic angiography of the breast
Kruger, R. A., Lam, R. B., Reinecke, D. R., Del Rio, S. P., & Doyle, R. P. (2010) · Medical Physics · doi:10.1118/1.3497677 · Cited by 302
Oraevsky, A. A., Jacques, S. L., & Tittel, F. K. (1997) · Applied Optics · doi:10.1364/ao.36.000402 · Cited by 298
An, L., Qin, J., & Wang, R. K. (2010) · Optics Express · doi:10.1364/oe.18.008220 · Cited by 291
Subwavelength-resolution label-free photoacoustic microscopy of optical absorption in vivo
Zhang, C., Maslov, K., & Wang, L. V. (2010) · Optics Letters · doi:10.1364/ol.35.003195 · Cited by 281
Self-citationNanoparticles for photoacoustic imaging
Yang, X., Stein, E. W., Ashkenazi, S., & Wang, L. V. (2009) · WIREs Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.42 · Cited by 265
Self-citationGalanzha, E. I., Shashkov, E. V., Spring, P. M., Suen, J. Y., & Zharov, V. P. (2009) · Cancer Research · doi:10.1158/0008-5472.can-08-4900 · Cited by 259
Photoacoustic ophthalmoscopy for in vivo retinal imaging
Jiao, S., Jiang, M., Hu, J., Fawzi, A., Zhou, Q., Shung, K. K., Puliafito, C. A., & Zhang, H. F. (2010) · Optics Express · doi:10.1364/oe.18.003967 · Cited by 258
Sentinel Lymph Nodes in the Rat: Noninvasive Photoacoustic and US Imaging with a Clinical US System
Erpelding, T. N., Kim, C., Pramanik, M., Jankovic, L., Maslov, K., Guo, Z., Margenthaler, J. A., Pashley, M. D., & Wang, L. V. (2010) · Radiology · doi:10.1148/radiol.10091772 · Cited by 252
Self-citationSensitivity of laser opto-acoustic imaging in detection of small deeply embedded tumors
Esenaliev, R. O., Karabutov, A. A., & Oraevsky, A. A. (1999) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.796320 · Cited by 239
Noninvasive photoacoustic computed tomography of mouse brain metabolism in vivo
Yao, J., Xia, J., Maslov, K. I., Nasiriavanaki, M., Tsytsarev, V., Demchenko, A. V., & Wang, L. V. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.08.054 · Cited by 235
Self-citationYang, J.-M., Maslov, K., Yang, H.-C., Zhou, Q., Shung, K. K., & Wang, L. V. (2009) · Optics Letters · doi:10.1364/ol.34.001591 · Cited by 229
Self-citationPhotoacoustic tomography: fundamentals, advances and prospects
Yao, J., & Wang, L. V. (2011) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.443 · Cited by 226
Self-citationIn vivo label-free photoacoustic microscopy of cell nuclei by excitation of DNA and RNA
Yao, D.-K., Maslov, K., Shung, K. K., Zhou, Q., & Wang, L. V. (2010) · Optics Letters · doi:10.1364/ol.35.004139 · Cited by 225
Self-citationSong, K. H., Stein, E. W., Margenthaler, J. A., & Wang, L. V. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2976427 · Cited by 225
Self-citationMatcher, S. J., Cope, M., & Delpy, D. T. (1997) · Applied Optics · doi:10.1364/ao.36.000386 · Cited by 221
Doppler optical micro-angiography for volumetric imaging of vascular perfusion in vivo
Wang, R. K., & An, L. (2009) · Optics Express · doi:10.1364/oe.17.008926 · Cited by 220
Burgholzer, P., Matt, G. J., Haltmeier, M., & Paltauf, G. (2007) · Physical Review E · doi:10.1103/physreve.75.046706 · Cited by 216
In vivo photoacoustic imaging of transverse blood flow by using Doppler broadening of bandwidth
Yao, J., Maslov, K. I., Shi, Y., Taber, L. A., & Wang, L. V. (2010) · Optics Letters · doi:10.1364/ol.35.001419 · Cited by 200
Self-citationAkers, W. J., Kim, C., Berezin, M., Guo, K., Fuhrhop, R., Lanza, G. M., Fischer, G. M., Daltrozzo, E., Zumbusch, A., Cai, X., et al. (2011) · ACS Nano · doi:10.1021/nn102274q · Cited by 192
Self-citationZhang, E. Z., Povazay, B., Laufer, J., Alex, A., Hofer, B., Pedley, B., Glittenberg, C., Treeby, B., Cox, B., Beard, P., et al. (2011) · Biomedical Optics Express · doi:10.1364/boe.2.002202 · Cited by 190
Photoacoustic imaging of lacZ gene expression in vivo
Li, L., Zemp, R. J., Lungu, G., Stoica, G., & Wang, L. V. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2717531 · Cited by 187
Self-citationAdvances in Photoacoustic Noninvasive Glucose Testing
MacKenzie, H. A., Ashton, H. S., Spiers, S., Shen, Y., Freeborn, S. S., Hannigan, J., Lindberg, J., & Rae, P. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.9.1587 · Cited by 186
Oladipupo, S., Hu, S., Kovalski, J., Yao, J., Santeford, A., Sohn, R. E., Shohet, R., Maslov, K., Wang, L. V., & Arbeit, J. M. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1101321108 · Cited by 183
Self-citationDeep reflection-mode photoacoustic imaging of biological tissue
Song, K. H., & Wang, L. V. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2818045 · Cited by 181
Self-citationEstimating chromophore distributions from multiwavelength photoacoustic images
Cox, B. T., Arridge, S. R., & Beard, P. C. (2009) · Journal of the Optical Society of America A · doi:10.1364/josaa.26.000443 · Cited by 174
Photoacoustic Doppler Effect from Flowing Small Light-Absorbing Particles
Fang, H., Maslov, K., & Wang, L. V. (2007) · Physical Review Letters · doi:10.1103/physrevlett.99.184501 · Cited by 171
Self-citationPhotoacoustic imaging of biological tissue with intensity-modulated continuous-wave laser
Maslov, K., & Wang, L. V. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2904965 · Cited by 168
Self-citationDeep‐Tissue Photoacoustic Tomography of a Genetically Encoded Near‐Infrared Fluorescent Probe
Filonov, G. S., Krumholz, A., Xia, J., Yao, J., Wang, L. V., & Verkhusha, V. V. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201107026 · Cited by 167
Self-citationLabel-Free Bond-Selective Imaging by Listening to Vibrationally Excited Molecules
Wang, H.-W., Chai, N., Wang, P., Hu, S., Dou, W., Umulis, D., Wang, L. V., Sturek, M., Lucht, R., & Cheng, J.-X. (2011) · Physical Review Letters · doi:10.1103/physrevlett.106.238106 · Cited by 163
Self-citationWide-field fast-scanning photoacoustic microscopy based on a water-immersible MEMS scanning mirror
Yao, J., Wang, L., Yang, J.-M., Gao, L. S., Maslov, K. I., Wang, L. V., Huang, C.-H., & Zou, J. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.8.080505 · Cited by 159
Self-citationLabel-free photoacoustic ophthalmic angiography
Hu, S., Rao, B., Maslov, K., & Wang, L. V. (2009) · Optics Letters · doi:10.1364/ol.35.000001 · Cited by 148
Self-citationLi, W., Cai, X., Kim, C., Sun, G., Zhang, Y. S., Deng, R., Yang, M., Chen, J., Achilefu, S., Wang, L. V., et al. (2011) · Nanoscale · doi:10.1039/c0nr00932f · Cited by 137
Self-citationIn vivo volumetric imaging of subcutaneous microvasculature by photoacoustic microscopy
Zhang, H. F., Maslov, K., Li, M., Stoica, G., & Wang, L. V. (2006) · Optics Express · doi:10.1364/oe.14.009317 · Cited by 131
Self-citationDetection of ultrawide-band ultrasound pulses in optoacoustic tomography
Андреев, В. Г., Karabutov, A. A., & Oraevsky, A. A. (2003) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2003.1244756 · Cited by 131
A 25-mm diameter probe for photoacoustic and ultrasonic endoscopy
Yang, J.-M., Chen, R., Favazza, C. P., Yao, J., Li, C., Hu, Z., Zhou, Q., Shung, K. K., & Wang, L. V. (2012) · Optics Express · doi:10.1364/oe.20.023944 · Cited by 130
Self-citationCho, E. C., Kim, C., Zhou, F., Cobley, C. M., Song, K. H., Chen, J., Li, Z.-Y., Wang, L. V., & Younan Xia, A. (2009) · The Journal of Physical Chemistry C · doi:10.1021/jp903343p · Cited by 128
Self-citationDevelopment of a catheter for combined intravascular ultrasound and photoacoustic imaging
Karpiouk, A. B., Wang, B., & Emelianov, S. (2010) · Review of Scientific Instruments · doi:10.1063/1.3274197 · Cited by 126
In-vivo photoacoustic microscopy of nanoshell extravasation from solid tumor vasculature
Li, M., Wang, J. C., Schwartz, J. A., Gill‐Sharp, K. L., Stoica, G., & Wang, L. V. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3081556 · Cited by 124
Self-citationWang, R. K., & Hurst, S. (2007) · Optics Express · doi:10.1364/oe.15.011402 · Cited by 124
Liao, L., Li, M.-L., Lai, H., Shih, Y. I., Lo, Y., Tsang, S., Chao, P. C.-P., Lin, C., Jaw, F.-S., & Chen, Y. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.03.065 · Cited by 123
Reflection-mode submicron-resolution in vivo photoacoustic microscopy
Zhang, C., Maslov, K., Hu, S., Wang, L. V., Chen, R., Zhou, Q., & Shung, K. K. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.2.020501 · Cited by 119
Self-citationNoninvasive label-free imaging of microhemodynamics by optical-resolution photoacoustic microscopy
Hu, S., Maslov, K., & Wang, L. V. (2009) · Optics Express · doi:10.1364/oe.17.007688 · Cited by 117
Self-citationIntravascular Photoacoustic Imaging
Wang, B., Su, J. L.-S., Karpiouk, A. B., Sokolov, K., Smalling, R. W., & Emelianov, S. (2010) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2009.2037023 · Cited by 114
Pure optical photoacoustic microscopy
Xie, Z., Chen, S., Ling, T., Guo, L. J., Carson, P. L., & Wang, X. (2011) · Optics Express · doi:10.1364/oe.19.009027 · Cited by 112
Neurovascular photoacoustic tomography
Hu, S., & Wang, L. V. (2010) · Frontiers in Neuroenergetics · doi:10.3389/fnene.2010.00010 · Cited by 111
Self-citationPhotoacoustic tomography of water in phantoms and tissue
Xu, Z., Li, C., & Wang, L. V. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3443793 · Cited by 104
Self-citationIn vivo functional photoacoustic microscopy of cutaneous microvasculature in human skin
Favazza, C. P., Wang, L. V., & Cornelius, L. A. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3536522 · Cited by 88
Self-citationOladipupo, S. S., Hu, S., Santeford, A. C., Yao, J., Kovalski, J. R., Shohet, R. V., Maslov, K., Wang, L. V., & Arbeit, J. M. (2011) · Blood · doi:10.1182/blood-2010-09-307538 · Cited by 87
Self-citationVideo-rate functional photoacoustic microscopy at depths
Wang, L., Maslov, K., Xing, W., Garcia‐Uribe, A., & Wang, L. V. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.10.106007 · Cited by 83
Self-citationTyrosinase as a dual reporter gene for both photoacoustic and magnetic resonance imaging
Paproski, R. J., Forbrich, A., Wachowicz, K., Hitt, M., & Zemp, R. J. (2011) · Biomedical Optics Express · doi:10.1364/boe.2.000771 · Cited by 82
Evans blue dye-enhanced capillary-resolution photoacoustic microscopy in vivo
Yao, J., Maslov, K., Hu, S., & Wang, L. V. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3251044 · Cited by 81
Self-citationOptimal ultraviolet wavelength for in vivo photoacoustic imaging of cell nuclei
Yao, D.-K., Maslov, K. I., Wang, L. V., Chen, R., & Zhou, Q. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.5.056004 · Cited by 81
Self-citationStimulated Raman photoacoustic imaging
Yakovlev, V. V., Zhang, H. F., Noojin, G. D., Denton, M. L., Thomas, R. J., & Scully, M. O. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1012432107 · Cited by 79
Transverse flow imaging based on photoacoustic Doppler bandwidth broadening
Yao, J., & Wang, L. V. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3339953 · Cited by 75
Self-citationLiu, T., Wei, Q., Wang, J., Jiao, S., & Zhang, H. F. (2011) · Biomedical Optics Express · doi:10.1364/boe.2.001359 · Cited by 71
Photoacoustic microscopy of tyrosinase reporter gene in vivo
Krumholz, A., Yao, J., Wang, L. V., et al. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3606568 · Cited by 70
Self-citationHu, S., Maslov, K., & Wang, L. V. (2009) · Medical Physics · doi:10.1118/1.3137572 · Cited by 68
Self-citationPhotoacoustic Doppler Flow Measurement in Optically Scattering Media
Fang, H., Maslov, K., & Wang, L. V. (2007) · Applied Physics Letters · doi:10.1063/1.2825569 · Cited by 64
Self-citationMultifocal optical-resolution photoacoustic microscopy in vivo
Song, L., Maslov, K., & Wang, L. V. (2011) · Optics Letters · doi:10.1364/ol.36.001236 · Cited by 64
Self-citationBrunker, J., & Beard, P. C. (2012) · The Journal of the Acoustical Society of America · doi:10.1121/1.4739458 · Cited by 63
Photoacoustic correlation spectroscopy and its application to low-speed flow measurement
Chen, S., Ling, T., Huang, S.-W., Baac, H. W., & Guo, L. J. (2010) · Optics Letters · doi:10.1364/ol.35.001200 · Cited by 62
Multi-Scale Molecular Photoacoustic Tomography of Gene Expression
Cai, X., Li, L., Krumholz, A., Guo, Z., Erpelding, T. N., Zhang, C., Zhang, Y. S., Younan Xia, A., & Wang, L. V. (2012) · PLoS ONE · doi:10.1371/journal.pone.0043999 · Cited by 61
Self-citationPhotoacoustic microscopy of microvascular responses to cortical electrical stimulation
Tsytsarev, V., Hu, S., Yao, J., Maslov, K., Barbour, D. L., & Wang, L. V. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3594785 · Cited by 54
Self-citationReal-time, contrast enhanced photoacoustic imaging of cancer in a mouse window chamber
Olafsson, R., Bauer, D. R., Montilla, L. G., & Witte, R. S. (2010) · Optics Express · doi:10.1364/oe.18.018625 · Cited by 53
LI, L., Zhang, H. F., Zemp, R. J., Maslov, K., & Wang, L. V. (2008) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545808000212 · Cited by 49
Self-citationLessons from the history of light microscopy
Amos, B. (2000) · Nature Cell Biology · doi:10.1038/35019639 · Cited by 47
Photoacoustic probing of fluorophore excited state lifetime with application to oxygen sensing
Ashkenazi, S., Huang, S.-W., Horvath, T. D., Koo, Y.-E. L., & Kopelman, R. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2927466 · Cited by 46
Functional photoacoustic microscopy of diabetic vasculature
Krumholz, A., Wang, L., Yao, J., & Wang, L. V. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.6.060502 · Cited by 44
Self-citationOptoacoustic tomography: New modality of laser diagnostic systems
Алексеевич, К. А., Savateeva, E. V., & Oraevsky, A. A. (2003) · Laser Physics · Cited by 42
Label-free photoacoustic microscopy of myocardial sheet architecture
Zhang, C., Wang, L. V., Chen, J., Chen, J., & Wickline, S. A. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.6.060506 · Cited by 40
Self-citationJiang, Y. Q., Forbrich, A., Harrison, T., & Zemp, R. J. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.3.036012 · Cited by 40
M-mode photoacoustic particle flow imaging
Fang, H., & Wang, L. V. (2009) · Optics Letters · doi:10.1364/ol.34.000671 · Cited by 39
Self-citationRowland, K. J., Yao, J., Wang, L., Erwin, C. R., Maslov, K., Wang, L. V., & Warner, B. W. (2012) · Journal of Pediatric Surgery · doi:10.1016/j.jpedsurg.2012.03.020 · Cited by 38
Self-citationPhotoacoustic flow measurements based on wash-in analysis of gold nanorods
Wei, C., Huang, S.-W., Wang, C.-R. C., & Li, P. (2007) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2007.367 · Cited by 36
Yao, J., Maslov, K., & Wang, L. V. (2012) · Technology in Cancer Research & Treatment · doi:10.7785/tcrt.2012.500278 · Cited by 34
Self-citationPhotoacoustic thermal diffusion flowmetry
Sheinfeld, A., & Eyal, A. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.000800 · Cited by 32
Collecting back-reflected photons in photoacoustic microscopy
Zhang, H. F., Wang, J. Y., Wei, Q., Liu, T., Jiao, S., & Puliafito, C. A. (2010) · Optics Express · doi:10.1364/oe.18.001278 · Cited by 30
Bitton, R. R., Zemp, R. J., Yen, J. T., Wang, L. V., & Shung, K. K. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2011899 · Cited by 28
Self-citation
Cited by
A practical guide to photoacoustic tomography in the life sciences
Wang, L. V., & Yao, J. (2016) · Nature Methods · doi:10.1038/nmeth.3925 · Cited by 1,394
Self-citationPHOTOACOUSTIC TOMOGRAPHY: PRINCIPLES AND ADVANCES (Invited Review)
Xia, J., Yao, J., & Wang, L. H. V. (2014) · Progress In Electromagnetics Research · doi:10.2528/pier14032303 · Cited by 646
Self-citationPhotoacoustic clinical imaging
Steinberg, I., Huland, D. M., Vermesh, O., Frostig, H. E., Tummers, W. S., & Gambhir, S. S. (2019) · Photoacoustics · doi:10.1016/j.pacs.2019.05.001 · Cited by 553
The emerging role of photoacoustic imaging in clinical oncology
Lin, L., & Wang, L. V. (2022) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-022-00615-3 · Cited by 469
Self-citationTutorial on photoacoustic tomography
Zhou, Y., Yao, J., & Wang, L. V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.6.061007 · Cited by 421
Self-citation
Metadata
- Authors
- Yao, J., & Wang, L. V.
- Venue
- Laser & Photonics Reviews
- Publisher
- Wiley
- Published
- 2013-01-31
- Volume
- 7
- Issue
- 5
- Pages
- 758-778
- ISSN
- 1863-8880 (ISSN-L)
- 1863-8899
- OpenAlex
- W2333144807
- Cited by
- 616
- References
- 119
- FWCI
- 9.92
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.