The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Advanced Wearable Microfluidic Sensors for Healthcare Monitoring
Abstract
Wearable flexible sensors based on integrated microfluidic networks with multiplex analysis capability are emerging as a new paradigm to assess human health status and show great potential in application fields such as clinical medicine and athletic monitoring. Well‐designed microfluidic sensors can be attached to the skin surface to acquire various pieces of physiological information with high precision, such as sweat loss, information regarding metabolites, and electrolyte balance. Herein, the recent progress of wearable microfluidic sensors for applications in healthcare monitoring is summarized, including analysis principles and microfabrication methods. Finally, the challenges and opportunities for wearable microfluidic sensors in practical applications are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Bariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308
3D printed microfluidic devices: enablers and barriers
Waheed, S., Cabot, J. M., Macdonald, N. P., Lewis, T., Guijt, R. M., Paull, B., & Breadmore, M. C. (2016) · Lab on a Chip · doi:10.1039/c6lc00284f · Cited by 1,039
Imani, S., Bandodkar, A. J., Mohan, A. M. V., Kumar, R., Yu, S., Wang, J., & Mercier, P. P. (2016) · Nature Communications · doi:10.1038/ncomms11650 · Cited by 861
Wearable Microfluidic Diaphragm Pressure Sensor for Health and Tactile Touch Monitoring
Gao, Y., Ota, H., Schaler, E. W., Chen, K., Zhao, A., Gao, W., Fahad, H. M., Leng, Y., Zheng, A., Xiong, F., et al. (2017) · Advanced Materials · doi:10.1002/adma.201701985 · Cited by 614
Correlation Between Sweat Glucose and Blood Glucose in Subjects with Diabetes
Moyer, J., Wilson, D., Finkelshtein, I., Wong, B., & Potts, R. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0262 · Cited by 570
Martín, A., Kim, J., Kurniawan, J. F., Sempionatto, J. R., Moreto, J. R., Tang, G., Campbell, A. S., Shin, A., Lee, M. Y., Liu, X., et al. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00729 · Cited by 475
Baker, L. B. (2017) · Sports Medicine · doi:10.1007/s40279-017-0691-5 · Cited by 403
Choi, J., Bandodkar, A. J., Reeder, J. T., Ray, T. R., Turnquist, A., Kim, S. B., Nyberg, N., Hourlier-Fargette, A., Model, J. B., Aranyosi, A. J., et al. (2019) · ACS Sensors · doi:10.1021/acssensors.8b01218 · Cited by 365
A potentiometric tattoo sensor for monitoring ammonium in sweat
Guinovart, T., Bandodkar, A. J., Windmiller, J. R., Andrade, F. J., & Wang, J. (2013) · The Analyst · doi:10.1039/c3an01672b · Cited by 343
Lipani, L., Dupont, B. G. R., Doungmene, F., Marken, F., Tyrrell, R. M., Guy, R. H., & Ilie, A. (2018) · Nature Nanotechnology · doi:10.1038/s41565-018-0112-4 · Cited by 340
Reeder, J. T., Choi, J., Xue, Y., Gutruf, P., Hanson, J., Liu, M., Ray, T., Bandodkar, A. J., Avila, R., Xia, W., et al. (2019) · Science Advances · doi:10.1126/sciadv.aau6356 · Cited by 308
Non‐invasive Analyte Access and Sensing through Eccrine Sweat: Challenges and Outlook circa 2016
Heikenfeld, J. (2016) · Electroanalysis · doi:10.1002/elan.201600018 · Cited by 294
A Textile‐Based Stretchable Multi‐Ion Potentiometric Sensor
Parrilla, M., Cánovas, R., Jeerapan, I., Andrade, F. J., & Wang, J. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201600092 · Cited by 269
Kumar, R., Shin, J., Yin, L., You, J., Meng, Y. S., & Wang, J. (2017) · Advanced Energy Materials · doi:10.1002/aenm.201602096 · Cited by 261
Sekine, Y., Kim, S. B., Zhang, Y., Bandodkar, A. J., Xu, S., Choi, J., Irie, M., Ray, T. R., Kohli, P., Kozai, N., et al. (2018) · Lab on a Chip · doi:10.1039/c8lc00530c · Cited by 242
Kamei, K.-I., Mashimo, Y., Koyama, Y., Fockenberg, C., Nakashima, M., Nakajima, M., Li, J., & Chen, Y. (2015) · Biomedical Microdevices · doi:10.1007/s10544-015-9928-y · Cited by 196
Thompson, B. L., Ouyang, Y., Duarte, G. R. M., Carrilho, E., Krauss, S. T., & Landers, J. P. (2015) · Nature Protocols · doi:10.1038/nprot.2015.051 · Cited by 149
Embroidered electrochemical sensors for biomolecular detection
Liu, X., & Lillehoj, P. B. (2016) · Lab on a Chip · doi:10.1039/c6lc00307a · Cited by 110
Wearable Potentiometric Chloride Sweat Sensor: The Critical Role of the Salt Bridge
Choi, D.-H., Kim, J. S., Cutting, G. R., & Searson, P. C. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b03391 · Cited by 100
Hydrogel-enabled osmotic pumping for microfluidics: towards wearable human-device interfaces
Shay, T., Dickey, M. D., & Velev, O. D. (2017) · Lab on a Chip · doi:10.1039/c6lc01486k · Cited by 71
Cited by
Advances in healthcare wearable devices
Iqbal, S. M. A., Mahgoub, I., Du, E., Leavitt, M. A., & Asghar, W. (2021) · npj Flexible Electronics · doi:10.1038/s41528-021-00107-x · Cited by 714
Microfluidic Paper-Based Analytical Devices: From Design to Applications
Noviana, E., Ozer, T., Carrell, C. S., Link, J. S., McMahon, C., Jang, I., & Henry, C. S. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01335 · Cited by 631
A wearable patch for continuous analysis of thermoregulatory sweat at rest
Nyein, H. Y. Y., Bariya, M., Tran, B., Ahn, C. H., Brown, B. J., Ji, W., Davis, N., & Javey, A. (2021) · Nature Communications · doi:10.1038/s41467-021-22109-z · Cited by 437
Mbunge, E., Muchemwa, B., Jiyane, S., & Batani, J. (2021) · Global Health Journal · doi:10.1016/j.glohj.2021.11.008 · Cited by 348
MXenes and Their Applications in Wearable Sensors
Xin, M., Li, J., Ma, Z., Pan, L., & Shi, Y. (2020) · Frontiers in Chemistry · doi:10.3389/fchem.2020.00297 · Cited by 246
Self-citation
Metadata
- Authors
- Li, S., Ma, Z., Cao, Z., Pan, L., & Shi, Y.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2019-10-16
- Volume
- 16
- Issue
- 9
- Pages
- e1903822-e1903822
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W2981090330
- Cited by
- 212
- References
- 24
- FWCI
- 7.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.