BBB ON CHIP: microfluidic platform to mechanically and biochemically modulate blood-brain barrier function
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834 · cited 4×
“…barrier Numerous reports have emphasized the importance of physiological levels of shear stress on endothelial cell function (van der Meer et al. 2010; Davies 2009; Li et al. 2005) in general and on cerebral microvascular endothelial physiology in particular (Huh et al. 2011; Cucullo et al 2008).”
BackgroundInfluentialBlood‐brain barrier‐specific properties of a human adult brain endothelial cell line
Weksler, B. B., Subileau, E. A., Perrière, N., Charneau, P., Holloway, K., Leveque, M., Tricoire‐Leignel, H., Nicotra, A., Bourdoulous, S., Turowski, P., et al. (2005) · The FASEB Journal · doi:10.1096/fj.04-3458fje · Cited by 1,330
Self-citationHemodynamic shear stress and the endothelium in cardiovascular pathophysiology
Davies, P. F. (2009) · Nature Clinical Practice Cardiovascular Medicine · doi:10.1038/ncpcardio1397 · Cited by 1,209
Molecular basis of the effects of shear stress on vascular endothelial cells
Li, Y.-S. J., Haga, J. H., & Chien, S. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.09.030 · Cited by 904
Characterization of a microfluidic in vitro model of the blood-brain barrier (μBBB)
Booth, R., & Kim, H. (2012) · Lab on a Chip · doi:10.1039/c2lc40094d · Cited by 739
Looking at the blood–brain barrier: Molecular anatomy and possible investigation approaches
Cardoso, F. L., Brites, D., & Brito, M. A. (2010) · Brain Research Reviews · doi:10.1016/j.brainresrev.2010.05.003 · Cited by 569
Strategies to advance translational research into brain barriers
Neuwelt, E., Abbott, N. J., Abrey, L., Banks, W. A., Blakley, B., Davis, T., Engelhardt, B., Grammas, P., Nedergaard, M., Nutt, J., et al. (2008) · The Lancet Neurology · doi:10.1016/s1474-4422(07)70326-5 · Cited by 474 · cited 1×
“3.5 Biochemical modulation of the barrier In addition to shear stress-induced enhancement of the endothelial barrier function, barrier properties can also be affected by biochemical stimulation, both in vivo and in vitro (Neuwelt et al. 2008; Forster et al. 2008; Bellavance et al. 2008).”
BackgroundInfluentialHatherell, K., Couraud, P.-O., Romero, I. A., Weksler, B., & Pilkington, G. J. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2011.05.012 · Cited by 334
Self-citationOrgans-on-chips: breaking the in vitro impasse
Meer, A. D. V. D., & Berg, A. V. D. (2012) · Integrative Biology · doi:10.1039/c2ib00176d · Cited by 314
Förster, C., Burek, M., Romero, I. A., Weksler, B., Couraud, P., & Drenckhahn, D. (2008) · The Journal of Physiology · doi:10.1113/jphysiol.2007.146852 · Cited by 307
Self-citation
Cited by
Bhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
TEER Measurement Techniques for In Vitro Barrier Model Systems
Srinivasan, B., Kolli, A. R., Esch, M. B., Abaci, H. E., Shuler, M. L., & Hickman, J. J. (2015) · SLAS Technology · doi:10.1177/2211068214561025 · Cited by 2,145
Organs-on-chips at the frontiers of drug discovery
Esch, E. W., Bahinski, A., & Huh, D. (2015) · Nature Reviews Drug Discovery · doi:10.1038/nrd4539 · Cited by 1,185
Helms, H. C., Abbott, N. J., Burek, M., Cecchelli, R., Couraud, P.-O., Deli, M. A., Förster, C., Galla, H. J., Romero, I. A., Shusta, E. V., et al. (2016) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x16630991 · Cited by 843
“Another approach has been to subject hCMEC/D3 monolayers to a physiological shear stress (about 5 dyn/cm(2)) in a microfluidic device, which increased TEER to 120 cm(2).(257) Thus, a number of studies have shown that the junctional tightness of the hCMEC/D3 model may be improved.”
BackgroundSelf-citationZhang, Y. S., Aleman, J., Shin, S. R., Kilic, T., Kim, D., Mousavi Shaegh, S. A., Massa, S., Riahi, R., Chae, S., Hu, N., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1612906114 · Cited by 833
Microfabrication of human organs-on-chips
Huh, D., Kim, H. J., Fraser, J. P., Shea, D. E., Khan, M., Bahinski, A., Hamilton, G. A., & Ingber, D. E. (2013) · Nature Protocols · doi:10.1038/nprot.2013.137 · Cited by 712
Organs-on-a-Chip: A Fast Track for Engineered Human Tissues in Drug Development
Ronaldson-Bouchard, K., & Vunjak-Novakovic, G. (2018) · Cell Stem Cell · doi:10.1016/j.stem.2018.02.011 · Cited by 657
“In addition tomodeling the BBB,models of the brain are also important per se, as the complexity of the human brain makes it difficult to study in non-human models.”
BackgroundMethodInfluentialVatine, G. D., Barrile, R., Workman, M. J., Sances, S., Barriga, B. K., Rahnama, M., Barthakur, S., Kasendra, M., Lucchesi, C., Kerns, J., et al. (2019) · Cell stem cell · doi:10.1016/j.stem.2019.05.011 · Cited by 632
Wang, Y. I., Abaci, H. E., & Shuler, M. L. (2017) · Biotechnology and Bioengineering · doi:10.1002/bit.26045 · Cited by 563
Herland, A., van der Meer, A. D., FitzGerald, E. A., Park, T.-E., Sleeboom, J. J. F., & Ingber, D. E. (2016) · PLOS ONE · doi:10.1371/journal.pone.0150360 · Cited by 476
Self-citationAdriani, G., Ma, D., Pavesi, A., Kamm, R. D., & Goh, E. L. K. (2017) · Lab on a Chip · doi:10.1039/c6lc00638h · Cited by 443
Development of Polymeric Nanoparticles for Blood–Brain Barrier Transfer—Strategies and Challenges
Zhang, W., Mehta, A., Tong, Z., Esser, L., & Voelcker, N. H. (2021) · Advanced Science · doi:10.1002/advs.202003937 · Cited by 430
Robotic fluidic coupling and interrogation of multiple vascularized organ chips
Novak, R., Ingram, M., Marquez, S., Das, D., Delahanty, A., Herland, A., Maoz, B. M., Jeanty, S. S. F., Somayaji, M. R., Burt, M., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0497-x · Cited by 427
Maoz, B. M., Herland, A., FitzGerald, E. A., Grevesse, T., Vidoudez, C., Pacheco, A. R., Sheehy, S. P., Park, T.-E., Dauth, S., Mannix, R., et al. (2018) · Nature Biotechnology · doi:10.1038/nbt.4226 · Cited by 425
Brown, J. A., Pensabene, V., Markov, D. A., Allwardt, V., Neely, M. D., Shi, M., Britt, C. M., Hoilett, O. S., Yang, Q., Brewer, B. M., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4934713 · Cited by 410
Ahn, S. I., Sei, Y. J., Park, H.-J., Kim, J., Ryu, Y., Choi, J. J., Sung, H.-J., MacDonald, T. J., Levey, A. I., & Kim, Y. (2020) · Nature Communications · doi:10.1038/s41467-019-13896-7 · Cited by 402
Glucose Transporters at the Blood-Brain Barrier: Function, Regulation and Gateways for Drug Delivery
Patching, S. G. (2017) · Molecular Neurobiology · doi:10.1007/s12035-015-9672-6 · Cited by 361
Advances in Hydrogels in Organoids and Organs‐on‐a‐Chip
Liu, H., Wang, Y., Cui, K., Guo, Y., Zhang, X., & Qin, J. (2019) · Advanced Materials · doi:10.1002/adma.201902042 · Cited by 353
Blood-brain-barrier spheroids as an in vitro screening platform for brain-penetrating agents
Cho, C.-F., Wolfe, J. M., Fadzen, C. M., Calligaris, D., Hornburg, K., Chiocca, E. A., Agar, N. Y. R., Pentelute, B. L., & Lawler, S. E. (2017) · Nature Communications · doi:10.1038/ncomms15623 · Cited by 336
Microfluidic organ-on-chip technology for blood-brain barrier research
van der Helm, M. W., van der Meer, A. D., Eijkel, J. C. T., van den Berg, A., & Segerink, L. I. (2016) · Tissue Barriers · doi:10.1080/21688370.2016.1142493 · Cited by 333
Self-citationOrgan-on-a-chip platforms: a convergence of advanced materials, cells, and microscale technologies
Ahadian, S., Civitarese, R., Bannerman, D., Mohammadi, M. H., Lu, R., Wang, E., Davenport‐Huyer, L., Lai, B., Zhang, B., Zhao, Y., et al. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700506 · Cited by 315
Industrial lab-on-a-chip: Design, applications and scale-up for drug discovery and delivery
Vladisavljević, G. T., Khalid, N., Neves, M. A., Kuroiwa, T., Nakajima, M., Uemura, K., Ichikawa, S., & Kobayashi, I. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.017 · Cited by 313
Scaling and systems biology for integrating multiple organs-on-a-chip
Wikswo, J. P., Curtis, E. L., Eagleton, Z. E., Evans, B. C., Kole, A., Hofmeister, L. H., & Matloff, W. J. (2013) · Lab on a Chip · doi:10.1039/c3lc50243k · Cited by 309
Marx, U. (2016) · ALTEX · doi:10.14573/altex.1603161 · Cited by 295
“Migration (Haessler et al., 2012; Hockemeyer et al., 2014), intravasation (Zervantonakis et al., 2012) extravasation (Bersini et al., 2014; Jeon et al., 2013) and metastasis (Griep et al., 2013) have been studied in such MPS-based cancer models.”
Blood–brain-barrier organoids for investigating the permeability of CNS therapeutics
Bergmann, S., Lawler, S. E., Qu, Y., Fadzen, C. M., Wolfe, J. M., Regan, M. S., Pentelute, B. L., Agar, N. Y. R., & Cho, C.-F. (2018) · Nature Protocols · doi:10.1038/s41596-018-0066-x · Cited by 285
Recent advances in microfluidic technologies for cell-to-cell interaction studies
Rothbauer, M., Zirath, H., & Ertl, P. (2018) · Lab on a Chip · doi:10.1039/c7lc00815e · Cited by 277
Maoz, B. M., Herland, A., Henry, O. Y. F., Leineweber, W. D., Yadid, M., Doyle, J., Mannix, R., Kujala, V. J., FitzGerald, E. A., Parker, K. K., et al. (2017) · Lab on a Chip · doi:10.1039/c7lc00412e · Cited by 266
Smith, A. M., & Dragunow, M. (2014) · Trends in Neurosciences · doi:10.1016/j.tins.2013.12.001 · Cited by 256
Organ-on-a-chip meets artificial intelligence in drug evaluation
Deng, S., Li, C., Cao, J., Cui, Z., Du, J., Fu, Z., Yang, H., & Chen, P. (2023) · Theranostics · doi:10.7150/thno.87266 · Cited by 260
Huda, M. N., Nafiujjaman, M., Deaguero, I. G., Okonkwo, J., Hill, M. L., Kim, T., & Nurunnabi, M. (2021) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.1c00217 · Cited by 254
Overcoming the Blood–Brain Barrier. Challenges and Tricks for CNS Drug Delivery
Bors, L. A., & Erdő, F. (2019) · Scientia Pharmaceutica · doi:10.3390/scipharm87010006 · Cited by 252
Mimicking liver sinusoidal structures and functions using a 3D-configured microfluidic chip
Du, Y., Li, N., Yang, H., Luo, C., Gong, Y., Tong, C., Gao, Y., Lü, S., & Long, M. (2017) · Lab on a Chip · doi:10.1039/c6lc01374k · Cited by 241
Fedi, A., Vitale, C., Ponschin, G., Ayehunie, S., Fato, M., & Scaglione, S. (2021) · Journal of Controlled Release · doi:10.1016/j.jconrel.2021.05.028 · Cited by 229
Organs-on-a-chip: a new tool for drug discovery
Polini, A., Prodanov, L., Bhise, N. S., Manoharan, V., Dokmeci, M. R., & Khademhosseini, A. (2014) · Expert Opinion on Drug Discovery · doi:10.1517/17460441.2014.886562 · Cited by 223
Microfabricated blood vessels for modeling the vascular transport barrier
Polacheck, W. J., Kutys, M. L., Tefft, J. B., & Chen, C. S. (2019) · Nature Protocols · doi:10.1038/s41596-019-0144-8 · Cited by 215
Measuring direct current trans-epithelial electrical resistance in organ-on-a-chip microsystems
Odijk, M., van der Meer, A. D., Levner, D., Kim, H. J., van der Helm, M. W., Segerink, L. I., Frimat, J.-P., Hamilton, G. A., Ingber, D. E., & van den Berg, A. (2015) · Lab on a Chip · doi:10.1039/c4lc01219d · Cited by 209
In Vitro Models of the Blood–Brain Barrier for the Study of Drug Delivery to the Brain
Wilhelm, I., & Krizbai, I. A. (2014) · Molecular Pharmaceutics · doi:10.1021/mp500046f · Cited by 211
Nanotechnology-based strategies for siRNA brain delivery for disease therapy
Zheng, M., Tao, W., Zou, Y., Farokhzad, O. C., & Shi, B. (2018) · Trends in biotechnology · doi:10.1016/j.tibtech.2018.01.006 · Cited by 210
Microfluidic Organ‐on‐a‐Chip Technology for Advancement of Drug Development and Toxicology
Caplin, J. D., Granados, N. G., James, M. R., Montazami, R., & Hashemi, N. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201500040 · Cited by 205
Lung-on-a-chip: the future of respiratory disease models and pharmacological studies
Shrestha, J., Razavi Bazaz, S., Aboulkheyr Es, H., Yaghobian Azari, D., Thierry, B., Ebrahimi Warkiani, M., & Ghadiri, M. (2020) · Critical Reviews in Biotechnology · doi:10.1080/07388551.2019.1710458 · Cited by 195
In-vitro blood–brain barrier modeling: A review of modern and fast-advancing technologies
Sivandzade, F., & Cucullo, L. (2018) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x18788769 · Cited by 189
Three-Dimensional Blood-Brain Barrier Model for in vitro Studies of Neurovascular Pathology
Cho, H., Seo, J. H., Wong, K. H. K., Terasaki, Y., Park, J., Bong, K., Arai, K., Lo, E. H., & Irimia, D. (2015) · Scientific Reports · doi:10.1038/srep15222 · Cited by 184
A Novel Dynamic Neonatal Blood-Brain Barrier on a Chip
Deosarkar, S. P., Prabhakarpandian, B., Wang, B., Sheffield, J. B., Krynska, B., & Kiani, M. F. (2015) · PLOS ONE · doi:10.1371/journal.pone.0142725 · Cited by 182
“Furthermore, the ability to visualize the dynamic processes in the neonatal B(3)C model in real time is a significant advantage as compared to flow based hollow fiber dynamic BBB models and other membrane based microfluidic approaches [17, 18, 24, 25, 40, 41].”
BackgroundMethodMechanical stress regulates transport in a compliant 3D model of the blood-brain barrier
Partyka, P. P., Godsey, G. A., Galie, J. R., Kosciuk, M. C., Acharya, N. K., Nagele, R. G., & Galie, P. A. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2016.11.012 · Cited by 179
Liu, W., Song, J., Du, X., Zhou, Y., Li, Y., Li, R., Lyu, L., He, Y., Hao, J., Ben, J., et al. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.04.053 · Cited by 173
Kim, J., Lee, K.-T., Lee, J. S., Shin, J., Cui, B., Yang, K., Choi, Y. S., Choi, N., Lee, S. H., Lee, J.-H., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00743-8 · Cited by 172
Stem Cell-Based Human Blood–Brain Barrier Models for Drug Discovery and Delivery
Aday, S., Cecchelli, R., Hallier-Vanuxeem, D., Dehouck, M. P., & Ferreira, L. (2016) · Trends in Biotechnology · doi:10.1016/j.tibtech.2016.01.001 · Cited by 169
“In addition, these models enable real-time monitoring of permeability and dynamic measurements of TEER [66,67].”
BackgroundHuman iPSC-Derived Endothelial Cells and Microengineered Organ-Chip Enhance Neuronal Development
Sances, S., Ho, R., Vatine, G., West, D., Laperle, A., Meyer, A., Godoy, M., Kay, P. S., Mandefro, B., Hatata, S., et al. (2018) · Stem Cell Reports · doi:10.1016/j.stemcr.2018.02.012 · Cited by 167
“…j Vol. 10 j 1222–1236 j April 10, 2018 models involving human neural and endothelial interaction have used human umbilical vein endothelial cells (Griep et al., 2013; Xu et al., 2016; Ye et al., 2014) or, more recently, iPSC sources of endothelial cells (Schwartz et al., 2015; Wang et al.,…”
Backgroundvan der Helm, M. W., Henry, O. Y. F., Bein, A., Hamkins-Indik, T., Cronce, M. J., Leineweber, W. D., Odijk, M., van der Meer, A. D., Eijkel, J. C. T., Ingber, D. E., et al. (2019) · Lab on a Chip · doi:10.1039/c8lc00129d · Cited by 161
Self-citationComplex Tissue and Disease Modeling using hiPSCs
Passier, R., Orlova, V., & Mummery, C. (2016) · Cell Stem Cell · doi:10.1016/j.stem.2016.02.011 · Cited by 142
“Simultaneous induction of liver organoids upon pulse induction ofGATA6 over a period of 5 dayswas reported recently (Guye et al., 2016).”
BackgroundSato, M., Sasaki, N., Ato, M., Hirakawa, S., Sato, K., & Sato, K. (2015) · PLOS ONE · doi:10.1371/journal.pone.0137301 · Cited by 124
Fowler, S., Chen, W. L. K., Duignan, D. B., Gupta, A., Hariparsad, N., Kenny, J. R., Lai, W. G., Liras, J., Phillips, J. A., & Gan, J. (2020) · Lab on a Chip · doi:10.1039/c9lc00857h · Cited by 109
Lee, J. B., & Sung, J. H. (2013) · Biotechnology Journal · doi:10.1002/biot.201300086 · Cited by 92
“During the last few years, several organ-on-a-chip systems have been developed, including blood vessel [32, 33], liver [34, 35], gastrointestinal tract [19, 36, 37], blood-brain-barrier [38, 39], lung [18, 40, 41], kidney [42, 43], and heart [21, 44, 45] equivalents.”
BackgroundYeste, J., García-Ramírez, M., Illa, X., Guimerà, A., Hernández, C., Simó, R., & Villa, R. (2018) · Lab on a Chip · doi:10.1039/c7lc00795g · Cited by 89
Soucy, J. R., Bindas, A. J., Koppes, A. N., & Koppes, R. A. (2019) · iScience · doi:10.1016/j.isci.2019.10.052 · Cited by 62
“Reprinted and adapted with permission from: A (Kujala et al., 2016); B (Maoz et al., 2017); C (Qian et al., 2017); D (Oleaga et al., 2019); and E (Agarwal et al., 2013; Grosberg et al., 2011; Lind et al., 2017).”
BackgroundBack and forth in time: Directing age in iPSC-derived lineages
Cornacchia, D., & Studer, L. (2017) · Brain Research · doi:10.1016/j.brainres.2015.11.013 · Cited by 56
Current Status of In vitro Models of the Blood-brain Barrier
Dong, X., & Shah, B. (2022) · Current Drug Delivery · doi:10.2174/1567201819666220303102614 · Cited by 42
In vitro micro-physiological models for translational immunology
Ramadan, Q., & Gijs, M. A. M. (2015) · Lab on a Chip · doi:10.1039/c4lc01271b · Cited by 41
Biotechnological advances and applications of human pluripotent stem cell-derived heart models
Muniyandi, P., O’Hern, C., Popa, M. A., & Aguirre, A. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1214431 · Cited by 14
Brain organoid methodologies to explore mechanisms of disease in progressive multiple sclerosis
Simões-Abade, M. B. C., Patterer, M., Nicaise, A. M., & Pluchino, S. (2024) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2024.1488691 · Cited by 14
Metadata
- Authors
- Griep, L. M., Wolbers, F., de Wagenaar, B., ter Braak, P. M., Weksler, B. B., Romero, I. A., Couraud, P. O., Vermes, I., van der Meer, A. D., & van den Berg, A.
- Venue
- Biomedical Microdevices
- Published
- 2012-09-06
- Volume
- 15
- Issue
- 1
- Pages
- 145-150
- ISSN
- 1387-2176 (ISSN-L)
- 1572-8781
- OpenAlex
- W1994504773
- Cited by
- 537
- References
- 28
- FWCI
- 10.70
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.