25 Years of Contrast-Enhanced MRI: Developments, Current Challenges and Future Perspectives
Open accessThe DOI matches its Crossref record; 128 of the 128 references it cites were found in a registry or an index.
Abstract
UNLABELLED: In 1988, the first contrast agent specifically designed for magnetic resonance imaging (MRI), gadopentetate dimeglumine (Magnevist(®)), became available for clinical use. Since then, a plethora of studies have investigated the potential of MRI contrast agents for diagnostic imaging across the body, including the central nervous system, heart and circulation, breast, lungs, the gastrointestinal, genitourinary, musculoskeletal and lymphatic systems, and even the skin. Today, after 25 years of contrast-enhanced (CE-) MRI in clinical practice, the utility of this diagnostic imaging modality has expanded beyond initial expectations to become an essential tool for disease diagnosis and management worldwide. CE-MRI continues to evolve, with new techniques, advanced technologies, and novel contrast agents bringing exciting opportunities for more sensitive, targeted imaging and improved patient management, along with associated clinical challenges. This review aims to provide an overview on the history of MRI and contrast media development, to highlight certain key advances in the clinical development of CE-MRI, to outline current technical trends and clinical challenges, and to suggest some important future perspectives. FUNDING: Bayer HealthCare.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diagnostic criteria for multiple sclerosis: 2010 revisions to the McDonald criteria
Polman, C. H., Reingold, S. C., Banwell, B., Clanet, M., Cohen, J. A., Filippi, M., Fujihara, K., Havrdova, E., Hutchinson, M., Kappos, L., et al. (2011) · Annals of Neurology · doi:10.1002/ana.22366 · Cited by 9,802
McDonald, W. I., Compston, A., Edan, G., Goodkin, D., Hartung, H., Lublin, F. D., McFarland, H. F., Paty, D. W., Polman, C. H., Reingold, S. C., et al. (2001) · Annals of Neurology · doi:10.1002/ana.1032 · Cited by 6,969
Relaxation Effects in Nuclear Magnetic Resonance Absorption
Bloembergen, N., Purcell, E. M., & Pound, R. V. (1948) · Physical Review · doi:10.1103/physrev.73.679 · Cited by 6,528
Diagnostic criteria for multiple sclerosis: 2005 revisions to the “McDonald Criteria”
Polman, C. H., Reingold, S. C., Edan, G., Filippi, M., Hartung, H., Kappos, L., Lublin, F. D., Metz, L. M., McFarland, H. F., O'Connor, P. W., et al. (2005) · Annals of Neurology · doi:10.1002/ana.20703 · Cited by 5,017 · cited 1×
“The value of CE-MRI for management of MS was reflected by inclusion of this modality in the McDonald criteria, originally in 2001 [92] and later in the 2005 and 2010 revised guidelines [93, 94].”
MethodGadolinium(III) Chelates as MRI Contrast Agents: Structure, Dynamics, and Applications
Caravan, P., Ellison, J. J., McMurry, T. J., & Lauffer, R. B. (1999) · Chemical Reviews · doi:10.1021/cr980440x · Cited by 4,483
New Multiple Sclerosis Phenotypic Classification
Lublin, F. D. (2014) · European Neurology · doi:10.1159/000367614 · Cited by 4,259
Bloch, F. (1946) · Physical Review · doi:10.1103/physrev.70.460 · Cited by 3,676
Image Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance
LAUTERBUR, P. C. (1973) · Nature · doi:10.1038/242190a0 · Cited by 3,611
Kim, R. J., Wu, E., Rafael, A., Chen, E.-L., Parker, M. A., Simonetti, O., Klocke, F. J., Bonow, R. O., & Judd, R. M. (2000) · New England Journal of Medicine · doi:10.1056/nejm200011163432003 · Cited by 3,306
Paramagnetic metal complexes as water proton relaxation agents for NMR imaging: theory and design
Lauffer, R. B. (1987) · Chemical Reviews · doi:10.1021/cr00081a003 · Cited by 1,978
Grobner, T. (2006) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfk062 · Cited by 1,859
Rohrer, M., Bauer, H., Mintorovitch, J., Requardt, M., & Weinmann, H.-J. (2005) · Investigative Radiology · doi:10.1097/01.rli.0000184756.66360.d3 · Cited by 1,682
Intracranial gadolinium deposition after contrast-enhanced MR imaging
McDonald, R. J., McDonald, J. S., Kallmes, D. F., Jentoft, M. E., Murray, D. L., Thielen, K. R., Williamson, E. E., & Eckel, L. J. (2015) · Radiology · doi:10.1148/radiol.15150025 · Cited by 1,358
Kanda, T., Ishii, K., Kawaguchi, H., Kitajima, K., & Takenaka, D. (2014) · Radiology · doi:10.1148/radiol.13131669 · Cited by 1,339
Diagnostic criteria for multiple sclerosis
Poser, C. M., & Brinar, V. V. (2001) · Clinical Neurology and Neurosurgery · doi:10.1016/s0303-8467(00)00125-6 · Cited by 1,283
Characteristics of gadolinium-DTPA complex: a potential NMR contrast agent
Weinmann, H., Brasch, R., Press, W., & Wesbey, G. (1984) · American Journal of Roentgenology · doi:10.2214/ajr.142.3.619 · Cited by 1,231
Greenwood, J. P., Maredia, N., Younger, J. F., Brown, J. M., Nixon, J., Everett, C. C., Bijsterveld, P., Ridgway, J. P., Radjenovic, A., Dickinson, C. J., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(11)61335-4 · Cited by 1,114
Law, M., Yang, S., Wang, H., Babb, J. S., Johnson, G., Cha, S., Knopp, E. A., & Zagzag, D. (2003) · PubMed Central · Cited by 1,084
Self-citationMagnetic resonance imaging of the breast: Recommendations from the EUSOMA working group
Sardanelli, F., Boetes, C., Borisch, B., Decker, T., Federico, M., Gilbert, F. J., Helbich, T., Heywang-Köbrunner, S. H., Kaiser, W. A., Kerin, M. J., et al. (2010) · European Journal of Cancer · doi:10.1016/j.ejca.2010.02.015 · Cited by 992
MRI Evaluation of the Contralateral Breast in Women with Recently Diagnosed Breast Cancer
Lehman, C. D., Gatsonis, C., Kuhl, C. K., Hendrick, R. E., Pisano, E. D., Hanna, L., Peacock, S., Smazal, S. F., Maki, D. D., Julian, T. B., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa065447 · Cited by 945
Gadolinium-enhanced MR aortography.
Prince, M. R. (1994) · Radiology · doi:10.1148/radiology.191.1.8134563 · Cited by 884
Self-citationTime‐resolved contrast‐enhanced 3D MR angiography
Korosec, F. R., Frayne, R., Grist, T. M., & Mistretta, C. A. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360304 · Cited by 877
Self-citationWyatt, J. S., Delpy, D. T., Cope, M., Wray, S., & Reynolds, E. O. R. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90467-8 · Cited by 876
Kanda, T., Fukusato, T., Matsuda, M., Toyoda, K., Oba, H., Kotoku, J., Haruyama, T., Kitajima, K., & Furui, S. (2015) · Radiology · doi:10.1148/radiol.2015142690 · Cited by 874
Kudo, M., Izumi, N., Kokudo, N., Matsui, O., Sakamoto, M., Nakashima, O., Kojiro, M., Makuuchi, M., & for the HCC Expert Panel of Japan Society of Hepatology (2011) · Digestive Diseases · doi:10.1159/000327577 · Cited by 825
Kuhl, C. (2007) · Radiology · doi:10.1148/radiol.2442051620 · Cited by 778
MRI for diagnosis of pure ductal carcinoma in situ: a prospective observational study
Kuhl, C. K., Schrading, S., Bieling, H. B., Wardelmann, E., Leutner, C. C., Koenig, R., Kuhn, W., & Schild, H. H. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61232-x · Cited by 711
Self-citationVillringer, A., Rosen, B. R., Belliveau, J. W., Ackerman, J. L., Lauffer, R. B., Buxton, R. B., Chao, Y., Wedeenand, V. J., & Brady, T. J. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910060205 · Cited by 706
Magnetic Resonance Perfusion Measurements for the Noninvasive Detection of Coronary Artery Disease
Nagel, E. C., Klein, C., Paetsch, I., Hettwer, S., Schnackenburg, B., Wegscheider, K., & Fleck, E. (2003) · Circulation · doi:10.1161/01.cir.0000080915.35024.a9 · Cited by 683
Kim, R. J., Chen, E.-L., Lima, J. A. C., & Judd, R. M. (1996) · Circulation · doi:10.1161/01.cir.94.12.3318 · Cited by 662
Superparamagnetic iron oxide based MRI contrast agents: Current status of clinical application.
Wáng, Y. X. J. (2011) · PubMed · doi:10.3978/j.issn.2223-4292.2011.08.03 · Cited by 613
Pharmacokinetics of GdDTPA/dimeglumine after intravenous injection into healthy volunteers.
Weinmann, H., Laniado, M., & Mutzel, W. (1984) · PubMed · Cited by 610
Breath-hold gadolinium-enhanced MR angiography of the abdominal aorta and its major branches.
Prince, M. R., Narasimham, D. L., Stanley, J. C., Chenevert, T. L., Williams, D. M., Marx, M. V., & Cho, K. J. (1995) · Radiology · doi:10.1148/radiology.197.3.7480757 · Cited by 592
Self-citationRadbruch, A., Weberling, L. D., Kieslich, P. J., Eidel, O., Burth, S., Kickingereder, P., Heiland, S., Wick, W., Schlemmer, H.-P., & Bendszus, M. (2015) · Radiology · doi:10.1148/radiol.2015150337 · Cited by 561
Stability of Gadolinium-Based Magnetic Resonance Imaging Contrast Agents in Human Serum at 37°C
Frenzel, T., Lengsfeld, P., Schirmer, H., Hütter, J., & Weinmann, H.-J. (2008) · Investigative Radiology · doi:10.1097/rli.0b013e3181852171 · Cited by 539
Self-citationKuhl, C. K., Schmutzler, R. K., Leutner, C. C., Kempe, A., Wardelmann, E., Hocke, A., Maringa, M., Pfeifer, U., Krebs, D., & Schild, H. H. (2000) · Radiology · doi:10.1148/radiology.215.1.r00ap01267 · Cited by 538
Self-citationBiodistribution of gadolinium‐based contrast agents, including gadolinium deposition
Aime, S., & Caravan, P. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21969 · Cited by 534
Superparamagnetic iron oxide: clinical application as a contrast agent for MR imaging of the liver.
Stark, D. D., Weissleder, R., Elizondo, G., Hahn, P. F., Saini, S., Todd, L. E., Wittenberg, J., & Ferrucci, J. T. (1988) · Radiology · doi:10.1148/radiology.168.2.3393649 · Cited by 512
Kuhl, C., Weigel, S., Schrading, S., Arand, B., Bieling, H., König, R., Tombach, B., Leutner, C., Rieber-Brambs, A., Nordhoff, D., et al. (2010) · Journal of Clinical Oncology · doi:10.1200/jco.2009.23.0839 · Cited by 501
Self-citationDynamic gadolinium‐enhanced three‐dimensional abdominal MR arteriography
Prince, M. R., Yucel, E. K., Kaufman, J. A., Harrison, D. C., & Geller, S. C. (1993) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880030614 · Cited by 499
Self-citationgadolinium-enchanced MR aortography.
Kumar, P. (1994) · Radiology · Cited by 495
Warach, S., Dashe, J. F., & Edelman, R. R. (1996) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199601000-00006 · Cited by 490
Kanda, T., Osawa, M., Oba, H., Toyoda, K., Kotoku, J., Haruyama, T., Takeshita, K., & Furui, S. (2015) · Radiology · doi:10.1148/radiol.14140364 · Cited by 488
NUCLEAR MAGNETIC RESONANCE IMAGING OF THE BRAIN IN MULTIPLE SCLEROSIS
Young, I. R., Hall, A. S., Pallis, C. A., Bydder, G. M., Legg, N. J., & Steiner, R. E. (1981) · The Lancet · doi:10.1016/s0140-6736(81)91273-3 · Cited by 470
Jaarsma, C., Leiner, T., Bekkers, S. C., Crijns, H. J., Wildberger, J. E., Nagel, E., Nelemans, P. J., & Schalla, S. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.12.040 · Cited by 456
Self-citationThomsen, H. S., Morcos, S. K., Almén, T., Bellin, M.-F., Bertolotto, M., Bongartz, G., Clement, O., Leander, P., Heinz-Peer, G., Reimer, P., et al. (2013) · European Radiology · doi:10.1007/s00330-012-2597-9 · Cited by 441
NMR in cancer: XVI. FONAR image of the live human body.
Damadian, R. V., Goldsmith, M. A., & Minkoff, L. A. (1977) · PubMed · Cited by 422
Errante, Y., Cirimele, V., Mallio, C. A., Di Lazzaro, V., Zobel, B. B., & Quattrocchi, C. C. (2014) · Investigative Radiology · doi:10.1097/rli.0000000000000072 · Cited by 421
Primovist, Eovist: What to expect?
Van Beers, B. E., Pastor, C. M., & Hussain, H. K. (2012) · Journal of Hepatology · doi:10.1016/j.jhep.2012.01.031 · Cited by 407
Huppertz, A., Balzer, T., Blakeborough, A., Breuer, J., Giovagnoni, A., Heinz-Peer, G., Laniado, M., Manfredi, R. M., Mathieu, D. G., Mueller, D., et al. (2004) · Radiology · doi:10.1148/radiol.2301020269 · Cited by 396
Image formation by induced local interactions. Examples employing nuclear magnetic resonance. 1973.
Pc, L. (1989) · PubMed · Cited by 391
Ringe, K. I., Husarik, D. B., Sirlin, C. B., & Merkle, E. M. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.10.4392 · Cited by 388
Sarica, O., Ozturk, E., Demirkurek, H. C., & Uluc, F. (2013) · Breast Care · doi:10.1159/000355833 · Cited by 356
Perfusion MRI: The Five Most Frequently Asked Clinical Questions
Essig, M., Nguyen, T. B., Shiroishi, M. S., Saake, M., Provenzale, J. M., Enterline, D. S., Anzalone, N., Dörfler, A., Rovira, À., Wintermark, M., et al. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9544 · Cited by 344
Self-citationPeripheral vascular tree stenoses: evaluation with moving-bed infusion-tracking MR angiography.
Ho, K. Y., Leiner, T., de Haan, M. W., Kessels, A. G., Kitslaar, P. J., & van Engelshoven, J. M. (1998) · Radiology · doi:10.1148/radiology.206.3.9494486 · Cited by 301
Self-citationGadolinium-DTPA as a contrast agent in MRI: initial clinical experience in 20 patients
Carr, D., Brown, J., Bydder, G., Steiner, R., Weinmann, H., Speck, U., Hall, A., & Young, I. (1984) · American Journal of Roentgenology · doi:10.2214/ajr.143.2.215 · Cited by 299
OGAN, M. D., SCHMIEDL, U., MOSELEY, M. E., GRODD, W., PAAJANEN, H., & BRASCH, R. C. (1987) · Investigative Radiology · doi:10.1097/00004424-198708000-00008 · Cited by 274
Image formation in NMR by a selective irradiative process
Garroway, A. N., Grannell, P. K., & Mansfield, P. (1974) · Journal of Physics C: Solid State Physics · doi:10.1088/0022-3719/7/24/006 · Cited by 271
Doña, I., Blanca‐López, N., Torres, M. J., García-Campos, J., García-Núñez, I., Gómez, F., Salas, M. L., Rondón, C., Canto, M. G., & Blanca, M. (2012) · PubMed · Cited by 269
Lee, C., & Hui, S. Y. R. (2013) · The HKU Scholars Hub (University of Hong Kong) · Cited by 269
MR contrast agents: Physical and pharmacologic basics
Lin, S., & Brown, J. J. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20955 · Cited by 259
Kitao, A., Matsui, O., Yoneda, N., Kozaka, K., Shinmura, R., Koda, W., Kobayashi, S., Gabata, T., Zen, Y., Yamashita, T., et al. (2011) · European Radiology · doi:10.1007/s00330-011-2165-8 · Cited by 258
Tissue-specific MR contrast agents
Weinmann, H.-J., Ebert, W., Misselwitz, B., & Schmitt-Willich, H. (2003) · European Journal of Radiology · doi:10.1016/s0720-048x(02)00332-7 · Cited by 250
PET/MR Imaging: Technical Aspects and Potential Clinical Applications
Torigian, D. A., Zaidi, H., Kwee, T. C., Saboury, B., Udupa, J. K., Cho, Z.-H., & Alavi, A. (2013) · Radiology · doi:10.1148/radiol.13121038 · Cited by 247
A new lipophilic gadolinium chelate as a tissue‐specific contrast medium for MRI
Weinmann, H. ‐., Schuhmann‐Giampieri, G., Schmitt‐Willich, H., Vogler, H., Frenzel, T., & Gries, H. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910220214 · Cited by 237
Self-citationEP-2104R: A Fibrin-Specific Gadolinium-Based MRI Contrast Agent for Detection of Thrombus
Overoye-Chan, K., Koerner, S., Looby, R. J., Kolodziej, A. F., Zech, S. G., Deng, Q., Chasse, J. M., McMurry, T. J., & Caravan, P. (2008) · Journal of the American Chemical Society · doi:10.1021/ja800834y · Cited by 226
Dynamic Contrast-Enhanced Magnetic Resonance Imaging in Oncology
Knopp, M. V., Giesel, F. L., Marcos, H. B., von Tengg‐Kobligk, H., & Choyke, P. L. (2001) · Topics in Magnetic Resonance Imaging · doi:10.1097/00002142-200108000-00006 · Cited by 215
Buckley, D. L., Roberts, C., Parker, G. J. M., Logue, J. P., & Hutchinson, C. E. (2004) · Radiology · doi:10.1148/radiol.2333032098 · Cited by 215
Magnetic resonance angiography: current status and future directions
Hartung, M. P., Grist, T. M., & François, C. J. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-19 · Cited by 213
Self-citationSieber, M. A., Pietsch, H., Walter, J., Haider, W., Frenzel, T., & Weinmann, H.-J. (2008) · Investigative Radiology · doi:10.1097/rli.0b013e31815e6277 · Cited by 207
Self-citationCruite, I., Schroeder, M., Merkle, E. M., & Sirlin, C. B. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.10.4538 · Cited by 205
Sieber, M. A., Lengsfeld, P., Frenzel, T., Golfier, S., Schmitt-Willich, H., Siegmund, F., Walter, J., Weinmann, H.-J., & Pietsch, H. (2008) · European Radiology · doi:10.1007/s00330-008-0977-y · Cited by 203
Self-citationParamagnetic contrast agents in nuclear magnetic resonance medical imaging
Mendonça-Dias, M. H., Gaggelli, E., & Lauterbur, P. C. (1983) · Seminars in Nuclear Medicine · doi:10.1016/s0001-2998(83)80048-8 · Cited by 202
MR imaging of thrombi using EP-2104R, a fibrin-specific contrast agent: initial results in patients
Spuentrup, E., Botnar, R. M., Wiethoff, A. J., Ibrahim, T., Kelle, S., Katoh, M., Özgun, M., Nagel, E., Vymazal, J., Graham, P. B., et al. (2008) · European Radiology · doi:10.1007/s00330-008-0965-2 · Cited by 188
Vymazal, J., Spuentrup, E., Cardenas-Molina, G., Wiethoff, A. J., Hartmann, M. G., Caravan, P., & Parsons, E. C. (2009) · Investigative Radiology · doi:10.1097/rli.0b013e3181b092a7 · Cited by 167
Macromolecular MRI contrast agents for imaging tumor angiogenesis
Barrett, T., Kobayashi, H., Brechbiel, M. W., & Choyke, P. L. (2006) · European Journal of Radiology · doi:10.1016/j.ejrad.2006.06.025 · Cited by 162
Jacques, V., Dumas, S., Sun, W.-C., Troughton, J. S., Greenfield, M. T., & Caravan, P. (2010) · Investigative Radiology · doi:10.1097/rli.0b013e3181ee6a49 · Cited by 158
Pharmacokinetics of Gadomer-17, a new dendritic magnetic resonance contrast agent
Misselwitz, B., Schmitt-Willich, H., Ebert, W., Frenzel, T., & Weinmann, H.-J. (2001) · Magnetic Resonance Materials in Physics, Biology and Medicine · doi:10.1007/bf02668094 · Cited by 158
Self-citationWang, Y., Alkasab, T. K., Narin, O., Nazarian, R. M., Kaewlai, R., Kay, J., & Abujudeh, H. H. (2011) · Radiology · doi:10.1148/radiol.11102340 · Cited by 152
Barkhof, F., Hommes, O. R., Scheltens, P., & Valk, J. (1991) · Neurology · doi:10.1212/wnl.41.8.1219 · Cited by 148
Quantitative Evaluation of Liver Function with MRI Using Gd-EOB-DTPA
Ryeom, H. K., Kim, S., Kim, J.-Y., Kim, H.-J., Lee, J. M., Chang, Y., Kim, Y., & Kang, D.-S. (2004) · Korean Journal of Radiology · doi:10.3348/kjr.2004.5.4.231 · Cited by 146
Self-citationMR angiography with blood pool contrast agents
Bremerich, J., Bilecen, D., & Reimer, P. (2007) · European Radiology · doi:10.1007/s00330-007-0712-0 · Cited by 139 · cited 1×
“These agents include gadofosveset and the ultrasmall superparamagnetic iron oxide (USPIO) particles (which have limited commercial availability) [40].”
BackgroundBarkhof, F., Rocca, M., Francis, G., van Waesberghe, J. T. M., Uitdehaag, B. M. J., Hommes, O. R., Hartung, H., Durelli, L., Edan, G., Fernández, O., et al. (2003) · Annals of Neurology · doi:10.1002/ana.10551 · Cited by 137
Hepatobiliary MR imaging: first human experience with MnDPDP.
Lim, K. O., Stark, D. D., Leese, P. T., Pfefferbaum, A., Rocklage, S. M., & Quay, S. C. (1991) · Radiology · doi:10.1148/radiology.178.1.1898539 · Cited by 130
Optimization of Gadolinium-Based Mri Contrast Agents for High Magnetic-Field Applications
Helm, L. (2010) · Future Medicinal Chemistry · doi:10.4155/fmc.09.174 · Cited by 129
A Historical Overview of Magnetic Resonance Imaging, Focusing on Technological Innovations
Ai, T., Morelli, J. N., Hu, X., Hao, D., Goerner, F. L., Ager, B., & Runge, V. M. (2012) · Investigative Radiology · doi:10.1097/rli.0b013e318272d29f · Cited by 128
MR Myocardial Perfusion Imaging
Coelho‐Filho, O. R., Rickers, C., Kwong, R. Y. K., & Jerosch‐Herold, M. (2013) · Radiology · doi:10.1148/radiol.12110918 · Cited by 114
Essig, M., Anzalone, N., Combs, S. E., Dörfler, A., Lee, S.-K., Picozzi, P., Rovira, À., Weller, M., & Law, M. (2011) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2640 · Cited by 113
Self-citationDumas, S., Jacques, V., Sun, W., Troughton, J. S., Welch, J., Chasse, J. M., Schmitt‐Willich, H., & Caravan, P. D. (2010) · Investigative Radiology · doi:10.1097/rli.0b013e3181ee5a9e · Cited by 112
Sala, E., Kataoka, M., Priest, A. N., Gill, A. B., McLean, M. A., Joubert, I., Graves, M. J., Crawford, R. A. F., Jimenez‐Liñan, M., Earl, H. M., et al. (2012) · Radiology · doi:10.1148/radiol.11110175 · Cited by 108
Ingrisch, M., Sourbron, S., Morhard, D., Ertl-Wagner, B., Kümpfel, T., Hohlfeld, R., Reiser, M., & Glaser, C. (2012) · Investigative Radiology · doi:10.1097/rli.0b013e31823bfc97 · Cited by 107
Gadolinium‐based contrast agents and NSF: Evidence from animal experience
Sieber, M. A., Steger‐Hartmann, T., Lengsfeld, P., & Pietsch, H. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21971 · Cited by 101
Self-citationKrautmacher, C., Willinek, W. A., Tschampa, H. J., Born, M. L., Träber, F., Gieseke, J., Textor, H. J., Schild, H. H., & Kuhl, C. K. (2005) · Radiology · doi:10.1148/radiol.2373041672 · Cited by 100
Self-citationHuang, C., & Tsourkas, A. (2013) · Current Topics in Medicinal Chemistry · doi:10.2174/1568026611313040002 · Cited by 94
Lévy, A., Medjhoul, A., Caramella, C., Zareski, É., Bergès, O., Chargari, C., Boulet, B., Bidault, F., Dromain, C., & Balleyguier, C. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22546 · Cited by 93
Hepatic MR imaging with Mn-DPDP: safety, image quality, and sensitivity.
Bernardino, M. E., Young, S. W., Lee, J. K., & Weinreb, J. C. (1992) · Radiology · doi:10.1148/radiology.183.1.1549694 · Cited by 92
Self-citationAcute Adverse Reactions to Gadolinium-Based Contrast Agents in CMR
Bruder, O., Schneider, S., Nothnagel, D., Pilz, G., Lombardi, M., Sinha, A. M., Wagner, A., Dill, T., Frank, H., van Rossum, A. C., et al. (2011) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2011.06.019 · Cited by 86
Pietsch, H., Lengsfeld, P., Steger‐Hartmann, T., Löwe, A., Frenzel, T., Hütter, J. F., & Sieber, M. A. (2009) · Investigative Radiology · doi:10.1097/rli.0b013e3181998eb7 · Cited by 83
Self-citationGadolinium-DTPA in MR imaging of glioblastomas and intracranial metastases.
Claussen, C. D., Laniado, M., Schörner, W., Niendorf, H.-P., Weinmann, H., Fiegler, W., & Felix, R. (1985) · PubMed Central · Cited by 83
MultiHance clinical pharmacology: Biodistribution and MR enhancement of the liver
Spinazzi, A., Lorusso, V., Pirovano, G., Taroni, P., Kirchin, M. A., & Davies, A. (1998) · Academic Radiology · doi:10.1016/s1076-6332(98)80069-x · Cited by 80
Magnetic resonance demonstration of multiple sclerosis plaques in the cervical cord
Maravilla, K., Weinreb, J., Suss, R. A., & Nunnally, R. (1985) · American Journal of Roentgenology · doi:10.2214/ajr.144.2.381 · Cited by 79
Self-citationAtherosclerotic Vascular Disease Conference: Writing Group IV: Imaging
Olin, J. W., Kaufman, J. A., Bluemke, D. A., Bonow, R. O., Gerhard, M. D., Jaff, M. R., Rubin, G. D., & Hall, W. (2004) · Circulation · doi:10.1161/01.cir.0000128521.02390.72 · Cited by 79
Forsting, M., & Palkowitsch, P. (2009) · European Journal of Radiology · doi:10.1016/j.ejrad.2009.06.005 · Cited by 77
Golden, D. I., Lipson, J. A., Telli, M. L., Ford, J. M., & Rubin, D. L. (2013) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2012-001460 · Cited by 77
Magnetic resonance contrast media: principles and progress.
Lauffer, R. B. (1990) · Magnetic resonance quarterly · Cited by 77
Peripheral Zone Prostate Cancer Localization by Multiparametric Magnetic Resonance at 3 T
Selnæs, K. M., Heerschap, A., Jensen, L. R., Tessem, M., Schweder, G. K. J.-V., Goa, P. E., Viset, T., Angelsen, A., & Gribbestad, I. S. (2012) · Investigative Radiology · doi:10.1097/rli.0b013e318263f0fd · Cited by 73
Woodard, P. K., Bluemke, D. A., Cascade, P. N., Finn, J. P., Stillman, A. E., Higgins, C. B., White, R. D., & Yucel, E. K. (2006) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2006.06.007 · Cited by 70
Contemporary Imaging of the Renal Mass
Kang, S. K., & Chandarana, H. (2012) · Urologic Clinics of North America · doi:10.1016/j.ucl.2012.01.002 · Cited by 67
Magnetic Resonance Angiography of Abdominal and Lower Extremity Vasculature
Leiner, T. (2005) · Topics in Magnetic Resonance Imaging · doi:10.1097/01.rmr.0000185431.50535.d7 · Cited by 66
Self-citationCost-effectiveness of MRI for breast cancer screening in BRCA1/2 mutation carriers
Pataky, R. E., Armstrong, L., Chia, S., Coldman, A. J., Kim‐Sing, C., McGillivray, B., Scott, J., Wilson, C., & Peacock, S. J. (2013) · BMC Cancer · doi:10.1186/1471-2407-13-339 · Cited by 64
Mistretta, C. A. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21683 · Cited by 61
Spuentrup, E., Katoh, M., Buecker, A., Fausten, B., Wiethoff, A. J., Wildberger, J. E., Haage, P., Parsons, E. C., Botnar, R. M., Graham, P. B., et al. (2007) · Investigative Radiology · doi:10.1097/rli.0b013e31804fa154 · Cited by 60
First use of GdDTPA/dimeglumine in man.
Laniado, M., Weinmann, H., Schörner, W., Felix, R., & Speck, U. (1984) · PubMed · Cited by 56
Liu, X.-J., Zou, L., Liu, F., Zhou, Y., & Song, B. (2013) · PLoS ONE · doi:10.1371/journal.pone.0070896 · Cited by 54
Anzalone, N., Gerevini, S., Scotti, R., Vezzulli, P. Q., & Picozzi, P. (2009) · Acta Radiologica · doi:10.1080/02841850903095385 · Cited by 52
Gaertner, F. C., Fürst, S., & Schwaiger, M. (2013) · Cancer Imaging · doi:10.1102/1470-7330.2013.0005 · Cited by 52
Quantitative multiparametric MRI of ovarian cancer
Carter, J. S., Koopmeiners, J. S., Kuehn-Hajder, J., Metzger, G. J., Lakkadi, N., Downs, L. S., & Bolan, P. J. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24119 · Cited by 52
Xu, B., Spincemaille, P., Chen, G., Agrawal, M., Nguyen, T. D., Prince, M. R., & Wang, Y. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24253 · Cited by 49
Self-citationWibmer, A. G., Qayyum, A., Steininger, R., Trauner, M., Stift, J., Mühlbacher, F., & Ba‐Ssalamah, A. (2012) · Investigative Radiology · doi:10.1097/rli.0b013e318245f7be · Cited by 46
Pietsch, H., Raschke, M., Ellinger-Ziegelbauer, H. C., Jošt, G., Walter, J., Frenzel, T., Lenhard, D. C., Hütter, J. F., & Sieber, M. A. (2010) · Investigative Radiology · doi:10.1097/rli.0b013e3181efd49a · Cited by 43
Self-citationScott, L. J. (2013) · Clinical Drug Investigation · doi:10.1007/s40261-013-0066-0 · Cited by 37
Time‐resolved contrast‐enhanced MR angiography of intracranial lesions
Zou, Z., Ma, L., Cheng, L., Cai, Y., & Meng, X. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21303 · Cited by 35
Optimizing Contrast-Enhanced Magnetic Resonance Imaging Characterization of Brain Metastases
Anzalone, N., Essig, M., Lee, S., Dörfler, A., Ganslandt, O., Combs, S. E., & Picozzi, P. (2013) · Neurosurgery · doi:10.1227/neu.0b013e3182889ddf · Cited by 32
Gadolinium-Based Contrast Agents for Vessel Wall Magnetic Resonance Imaging (MRI) of Atherosclerosis
Calcagno, C., Ramachandran, S., Millon, A., Robson, P. M., Mani, V., & Fayad, Z. A. (2012) · Current Cardiovascular Imaging Reports · doi:10.1007/s12410-012-9177-x · Cited by 31
Advanced Techniques Using Contrast Media in Neuroimaging
Ferré, J., Shiroishi, M. S., & Law, M. (2012) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2012.07.007 · Cited by 28
Self-citationTop 100 Cited AJR Articles at the AJR's Centennial
Bui-Mansfield, L. T. (2005) · American Journal of Roentgenology · doi:10.2214/ajr.05.1186 · Cited by 22
Schörner, W., Kazner, E., Laniado, M., Sprung, C., & Felix, R. (1984) · Neurosurgical Review · doi:10.1007/bf01892910 · Cited by 17
Contrast-Enhanced Cardiac Magnetic Resonance Imaging
Restrepo, C. S., Tavakoli, S., & Marmol-Velez, A. (2012) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2012.07.005 · Cited by 8
Cited by
Chemistry of MRI Contrast Agents: Current Challenges and New Frontiers
Wahsner, J., Gale, E. M., Rodríguez-Rodríguez, A., & Caravan, P. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00363 · Cited by 1,603
Glymphatic MRI in idiopathic normal pressure hydrocephalus
Ringstad, G., Vatnehol, S. A. S., & Eide, P. K. (2017) · Brain · doi:10.1093/brain/awx191 · Cited by 722
“Regarding glymphatic transport, gadobutrol also has the advantages of even smaller molecular size (molecular weight 604 Da) than GdDTPA, and higher T1 relaxation (Lohrke et al., 2016).”
BackgroundEngineering of inorganic nanoparticles as magnetic resonance imaging contrast agents
Ni, D., Bu, W., Ehlerding, E. B., Cai, W., & Shi, J. (2017) · Chemical Society Reviews · doi:10.1039/c7cs00316a · Cited by 484
Eide, P. K., Vatnehol, S. A. S., Emblem, K. E., & Ringstad, G. (2018) · Scientific Reports · doi:10.1038/s41598-018-25666-4 · Cited by 299
Wang, Y., Spincemaille, P., Liu, Z., Dimov, A., Deh, K., Li, J., Zhang, Y., Yao, Y., Gillen, K. M., Wilman, A. H., et al. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25693 · Cited by 273
Self-citation
Metadata
- Authors
- Lohrke, J., Frenzel, T., Endrikat, J., Alves, F. C., Grist, T. M., Law, M., Lee, J. M., Leiner, T., Li, K.-C., Nikolaou, K., Prince, M. R., Schild, H. H., Weinreb, J. C., Yoshikawa, K., & Pietsch, H.
- Venue
- Advances in Therapy
- Published
- 2016-01
- Volume
- 33
- Issue
- 1
- Pages
- 1-28
- ISSN
- 0741-238X (ISSN-L)
- 1865-8652
- OpenAlex
- W2268080112
- Cited by
- 420
- References
- 128
- FWCI
- 27.86
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.