Fabrication of nitric oxide-releasing polyurethane glucose sensor membranes
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Despite clear evidence that polymeric nitric oxide (NO) release coatings reduce the foreign body response (FBR) and may thus improve the analytical performance of in vivo continuous glucose monitoring devices when used as sensor membranes, the compatibility of the NO release chemistry with that required for enzymatic glucose sensing remains unclear. Herein, we describe the fabrication and characterization of NO-releasing polyurethane sensor membranes using NO donor-modified silica vehicles embedded within the polymer. In addition to demonstrating tunable NO release as a function of the NO donor silica scaffold and polymer compositions and concentrations, we describe the impact of the NO release vehicle and its release kinetics on glucose sensor performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707 · cited 1×
“The fabricated NO-releasing particle-doped membranes were characterized as having adequate selectivity over known interferents (Heller and Feldman, 2008; Wilson and Gifford, 2005).”
BackgroundNitric oxide donors: chemical activities and biological applications
Wang, P. G., Xian, M., Tang, X., Wu, X., Wen, Z., Cai, T., & Janczuk, A. J. (2002) · Chemical Reviews · doi:10.1021/cr000040l · Cited by 1,337
Reducing implant-related infections: active release strategies
Hetrick, E. M., & Schoenfisch, M. H. (2006) · Chemical Society Reviews · doi:10.1039/b515219b · Cited by 1,201
Self-citationBiosensors for real-time in vivo measurements
Wilson, G. S., & Gifford, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.003 · Cited by 660 · cited 10×
“Based on the reduced FBR as a function of NO release, we sought to combine the chemistries of NO release with enzymatic glucose sensing to fabricate continuous glucose monitoring devices with improved biocompatibility and extended analytical performance.”
BackgroundInfluentialMethods for reducing biosensor membrane biofouling
Wisniewski, N., & Reichert, M. (2000) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(99)00148-4 · Cited by 543 · cited 1×
“Undesirable sensor performance has een attributed to the foreign body response (FBR) and biofouling Wisniewski et al., 2000; Wisniewski and Reichert, 2000).”
BackgroundEnzyme-Based Biosensors for in Vivo Measurements
Wilson, G. S., & Hu, Y. (2000) · Chemical Reviews · doi:10.1021/cr990003y · Cited by 434
Frost, M. C., Reynolds, M. M., & Meyerhoff, M. E. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.06.006 · Cited by 343
Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring
Bindra, D. S., Zhang, Y., Wilson, G. S., Sternberg, R., Thevenot, D. R., Moatti, D., & Reach, G. (1991) · Analytical Chemistry · doi:10.1021/ac00017a008 · Cited by 309 · cited 1×
“This change may be attributed to decreased water uptake rate by the thicker membrane, as previously observed for other polyurethane coated glucose sensors (Bindra et al., 1991; Yan et al., 2011).”
BackgroundReduced foreign body response at nitric oxide-releasing subcutaneous implants
Hetrick, E. M., Prichard, H. L., Klitzman, B., & Schoenfisch, M. H. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.06.036 · Cited by 158 · cited 3×
“Concomitantly, the NO-releasing implant lessened the chronic inflammatory response at the tissue/implant interface by >30% and enhanced blood vessel formation by >77% versus controls (Hetrick et al., 2007).”
BackgroundInfluentialSelf-citationNitric oxide-releasing S-nitrosothiol-modified xerogels
Riccio, D. A., Dobmeier, K. P., Hetrick, E. M., Privett, B. J., Paul, H. S., & Schoenfisch, M. H. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.05.006 · Cited by 107 · cited 1×
“All rights reserved. et al., 2005b; Riccio et al., 2009).”
BackgroundSelf-citationMediation of in vivo glucose sensor inflammatory response via nitric oxide release
Gifford, R., Batchelor, M. M., Lee, Y., Gokulrangan, G., Meyerhoff, M. E., & Wilson, G. S. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30359 · Cited by 96 · cited 6×
“Simlar to previously reported in vivo NO-releasing glucose sensors Gifford et al., 2005), the sensitivity and response time (t95”
BackgroundMethodInfluentialA new amperometric glucose microsensor: in vitro and short-term in vivo evaluation
Ward, W. K., Jansen, L. B., Anderson, E., Reach, G., Klein, J.-C., & Wilson, G. S. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00268-8 · Cited by 81
Antibacterial properties of nitric oxide–releasing sol‐gels
Nablo, B. J., & Schoenfisch, M. H. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.20030 · Cited by 78
Self-citationNitric Oxide-Releasing Sol−Gel Particle/Polyurethane Glucose Biosensors
Shin, J. H., Marxer, S. M., & Schoenfisch, M. H. (2004) · Analytical Chemistry · doi:10.1021/ac049776z · Cited by 71 · cited 14×
“(1) (Shin et al., 2008) where IGlu and Ij re the measured current values for glucose (Glu) and interfering pecies (j = ascorbic acid, uric acid, and nitrite), respectively. og KampGlu,j = log ( Ij/cj IGlu/cGlu ) (1) The concentration of each interfering substance (cj) was 00 M.”
BackgroundMethodInfluentialSelf-citationNitric Oxide-Releasing Electrospun Polymer Microfibers
Coneski, P. N., Nash, J. A., & Schoenfisch, M. H. (2011) · ACS Applied Materials & Interfaces · doi:10.1021/am101010e · Cited by 47
Self-citationEfficacy of surface-generated nitric oxide against Candida albicans adhesion and biofilm formation
Privett, B. J., Nutz, S. T., & Schoenfisch, M. H. (2010) · Biofouling · doi:10.1080/08927014.2010.534552 · Cited by 45 · cited 1×
“These materials were shown to reduce bacterial adhesion (Nablo et al., 2001; Nablo and Schoenfisch, 2003), kill bacteria that did manage to adhere (Hetrick and Schoenfisch, 2007; Hetrick et al., 2008; Privett et al., 2010), and reduce in vivo infection rates (Nablo et al., 2005a).”
BackgroundSelf-citationYan, Q., Major, T. C., Bartlett, R. H., & Meyerhoff, M. E. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.04.026 · Cited by 41
Increased In Vivo Glucose Recovery via Nitric Oxide Release
Nichols, S. P., Le, N. N., Klitzman, B., & Schoenfisch, M. H. (2011) · Analytical Chemistry · doi:10.1021/ac103070t · Cited by 26 · cited 1×
“We recently reported enhanced in vivo glucose recovery from NO-releasing microdialysis probes during long-term (i.e., 2 weeks) implantation (Nichols et al., 2011).”
BackgroundSelf-citation
Cited by
Nitric oxide release: Part I. Macromolecular scaffolds
Riccio, D. A., & Schoenfisch, M. H. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15272j · Cited by 475
Self-citationCarpenter, A. W., Worley, B. V., Slomberg, D. L., & Schoenfisch, M. H. (2012) · Biomacromolecules · doi:10.1021/bm301108x · Cited by 132
Self-citationThe effect of nitric oxide surface flux on the foreign body response to subcutaneous implants
Nichols, S. P., Koh, A., Brown, N. L., Rose, M. B., Sun, B., Slomberg, D. L., Riccio, D. A., Klitzman, B., & Schoenfisch, M. H. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.05.053 · Cited by 67
“As shown in Table 1, the four PUs used in the study were chosen in part due to their water uptake [29].”
MethodSelf-citation
Metadata
- Authors
- Koh, A., Riccio, D. A., Sun, B., Carpenter, A. W., Nichols, S. P., & Schoenfisch, M. H.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2011-10
- Volume
- 28
- Issue
- 1
- Pages
- 17-24
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2116033695
- Cited by
- 37
- References
- 18
- FWCI
- 2.45
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.