Benefits and costs, an eternal balance
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Computed tomography (CT) technology has changed considerably in recent years with the introduction of increasing numbers of multiple detector arrays. There are several parameters specific to multi-detector computed tomography (MDCT) scanners that increase or decrease patient dose systematically compared to older single detector computed tomography (SDCT) scanners. This document briefly reviews the MDCT technology, radiation dose in MDCT, including differences from SDCT and factors that affect dose, radiation risks, and the responsibilities for patient dose management. The document recommends that users need to understand the relationship between patient dose and image quality and be aware that image quality in CT is often higher than that necessary for diagnostic confidence. Automatic exposure control (AEC) does not totally free the operator from selection of scan parameters, and awareness of individual systems is important. Scanning protocols cannot simply be transferred between scanners from different manufacturers and should be determined for each MDCT. If the image quality is appropriately specified by the user, and suited to the clinical task, there will be a reduction in patient dose for most patients. Understanding of some parameters is not intuitive and the selection of image quality parameter values in AEC systems is not straightforward. Examples of some clinical situation shave been included to demonstrate dose management, e.g. CT examinations of the chest, the heart for coronary calcium quantification and non-invasive coronary angiography, colonography, the urinary tract, children, pregnant patients, trauma cases, and CT guided interventions. CT is increasingly being used to replace conventional x-ray studies and it is important that patient dose is given careful consideration, particularly with repeated or multiple examinations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ng, C. S., Watson, C. J. E., Palmer, C. R., See, T. C., Beharry, N., Housden, B. A., Bradley, J. A., & Dixon, A. K. (2002) · BMJ · doi:10.1136/bmj.325.7377.1387 · Cited by 175
Self-citation
Research works printed but not linked: 4
- 10.1259/bjr/14928972 · doi:10.1259/bjr/14928972
- 10.1007/s00330-001-1268-z · doi:10.1007/s00330-001-1268-z
- RCR, 2007, Making the best use of Radiological Services: guidelines for doctors
- 10.1002/cncr.22668 · DOI
Cited by
Smith-Bindman, R. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.427 · Cited by 2,464
Projected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007
Berrington de González, A. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.440 · Cited by 1,888
Miglioretti, D. L., Johnson, E., Williams, A., Greenlee, R. T., Weinmann, S., Solberg, L. I., Feigelson, H. S., Roblin, D., Flynn, M. J., Vanneman, N., et al. (2013) · JAMA Pediatrics · doi:10.1001/jamapediatrics.2013.311 · Cited by 1,476
Exposure to Low-Dose Ionizing Radiation from Medical Imaging Procedures
Fazel, R., Krumholz, H. M., Wang, Y., Ross, J. S., Chen, J., Ting, H. H., Shah, N. D., Nasir, K., Einstein, A. J., & Nallamothu, B. K. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0901249 · Cited by 1,338
Bolch, W. E., Eckerman, K. F., Sgouros, G., & Thomas, S. R. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.056036 · Cited by 913
Smith-Bindman, R., Miglioretti, D. L., Johnson, E., Lee, C., Feigelson, H. S., Flynn, M., Greenlee, R. T., Kruger, R. L., Hornbrook, M. C., Roblin, D., et al. (2012) · JAMA · doi:10.1001/jama.2012.5960 · Cited by 898
Strategies for Reducing Radiation Dose in CT
McCollough, C. H., Primak, A. N., Braun, N., Kofler, J., Yu, L., & Christner, J. (2009) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2008.10.006 · Cited by 842
Sgouros, G., Roeske, J. C., McDevitt, M. R., Palm, S., Allen, B. J., Fisher, D. R., Brill, A. B., Song, H., Howell, R. W., & Akabani, G. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.058651 · Cited by 552
Ludlow, J. B., Timothy, R., Walker, C., Hunter, R., Benavides, E., Samuelson, D. B., & Scheske, M. J. (2015) · Dentomaxillofacial Radiology · doi:10.1259/dmfr.20140197 · Cited by 487
Hachamovitch, R., Rozanski, A., Shaw, L. J., Stone, G. W., Thomson, L. E. J., Friedman, J. D., Hayes, S. W., Cohen, I., Germano, G., & Berman, D. S. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq500 · Cited by 481
Diagnosis of pulmonary hypertension
Frost, A., Badesch, D., Gibbs, J. S. R., Gopalan, D., Khanna, D., Manes, A., Oudiz, R., Satoh, T., Torres, F., & Torbicki, A. (2019) · European Respiratory Journal · doi:10.1183/13993003.01904-2018 · Cited by 479
Guidelines for Patient Radiation Dose Management
Stecker, M. S., Balter, S., Towbin, R. B., Miller, D. L., Vañó, E., Bartal, G., Angle, J. F., Chao, C. P., Cohen, A. M., Dixon, R. G., et al. (2009) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2009.04.037 · Cited by 449
Long-term effects of radiation exposure on health
Kamiya, K., Ozasa, K., Akiba, S., Niwa, O., Kodama, K., Takamura, N., Zaharieva, E. K., Kimura, Y., & Wakeford, R. (2015) · The Lancet · doi:10.1016/s0140-6736(15)61167-9 · Cited by 446
Leuraud, K., Richardson, D. B., Cardis, E., Daniels, R. D., Gillies, M., O'Hagan, J. A., Hamra, G. B., Haylock, R., Laurier, D., Moissonnier, M., et al. (2015) · The Lancet Haematology · doi:10.1016/s2352-3026(15)00094-0 · Cited by 442
CBCT in orthodontics: assessment of treatment outcomes and indications for its use
Kapila, S. D., & Nervina, J. M. (2015) · Dentomaxillofacial Radiology · doi:10.1259/dmfr.20140282 · Cited by 423
Cancer risks associated with external radiation from diagnostic imaging procedures
Linet, M. S., Slovis, T. L., Miller, D. L., Kleinerman, R., Lee, C., Rajaraman, P., & Berrington de Gonzalez, A. (2012) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21132 · Cited by 420
Lameris, W., van Randen, A., van Es, H. W., van Heesewijk, J. P. M., van Ramshorst, B., Bouma, W. H., ten Hove, W., van Leeuwen, M. S., van Keulen, E. M., Dijkgraaf, M. G. W., et al. (2009) · BMJ · doi:10.1136/bmj.b2431 · Cited by 416
Radiation dose reduction in computed tomography: techniques and future perspective
Yu, L., Liu, X., Leng, S., Kofler, J. M., Ramirez-Giraldo, J. C., Qu, M., Christner, J., Fletcher, J. G., & McCollough, C. H. (2009) · Imaging in Medicine · doi:10.2217/iim.09.5 · Cited by 395
Richardson, D. B., Cardis, E., Daniels, R. D., Gillies, M., O’Hagan, J. A., Hamra, G. B., Haylock, R., Laurier, D., Leuraud, K., Moissonnier, M., et al. (2015) · BMJ · doi:10.1136/bmj.h5359 · Cited by 379
Medical imaging and nuclear medicine: a Lancet Oncology Commission
Hricak, H., Abdel-Wahab, M., Atun, R., Lette, M. M., Paez, D., Brink, J. A., Donoso-Bach, L., Frija, G., Hierath, M., Holmberg, O., et al. (2021) · The Lancet Oncology · doi:10.1016/s1470-2045(20)30751-8 · Cited by 368
Verberne, H. J., Acampa, W., Anagnostopoulos, C., Ballinger, J., Bengel, F., De Bondt, P., Buechel, R. R., Cuocolo, A., van Eck-Smit, B. L. F., Flotats, A., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3139-x · Cited by 366
Picano, E., Vano, E., Rehani, M. M., Cuocolo, A., Mont, L., Bodi, V., Bar, O., Maccia, C., Pierard, L., Sicari, R., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht394 · Cited by 361
Venneri, L., Rossi, F., Botto, N., Andreassi, M. G., Salcone, N., Emad, A., Lazzeri, M., Gori, C., Vano, E., & Picano, E. (2009) · American Heart Journal · doi:10.1016/j.ahj.2008.08.009 · Cited by 360
Radiation exposure in X-ray-based imaging techniques used in osteoporosis
Damilakis, J., Adams, J. E., Guglielmi, G., & Link, T. M. (2010) · European Radiology · doi:10.1007/s00330-010-1845-0 · Cited by 356
Ciraj‐Bjelac, O., Rehani, M. M., Sim, K. H., Liew, H. B., Vano, E., & Kleiman, N. J. (2010) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.22670 · Cited by 330
Heidbuchel, H., Wittkampf, F. H. M., Vano, E., Ernst, S., Schilling, R., Picano, E., Mont, L., ESC Scientific Document Group, Jais, P., de Bono, J., et al. (2014) · EP Europace · doi:10.1093/europace/eut409 · Cited by 311
on behalf of the OPTIMA study group, van Randen, A., Laméris, W., van Es, H. W., van Heesewijk, H. P. M., van Ramshorst, B., ten Hove, W., Bouma, W. H., van Leeuwen, M. S., van Keulen, E. M., et al. (2011) · European Radiology · doi:10.1007/s00330-011-2087-5 · Cited by 300
Potassium Intake, Bioavailability, Hypertension, and Glucose Control
Stone, M., Martyn, L., & Weaver, C. (2016) · Nutrients · doi:10.3390/nu8070444 · Cited by 287
Vano, E., Kleiman, N. J., Duran, A., Romano-Miller, M., & Rehani, M. M. (2013) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2012.10.016 · Cited by 268
Exposing the Thyroid to Radiation: A Review of Its Current Extent, Risks, and Implications
Sinnott, B., Ron, E., & Schneider, A. B. (2010) · Endocrine Reviews · doi:10.1210/er.2010-0003 · Cited by 246
Smith-Bindman, R., Wang, Y., Chu, P., Chung, R., Einstein, A. J., Balcombe, J., Cocker, M., Das, M., Delman, B. N., Flynn, M., et al. (2019) · BMJ · doi:10.1136/bmj.k4931 · Cited by 242
Cumulative Radiation Exposure and Cancer Risk Estimation in Children With Heart Disease
Johnson, J. N., Hornik, C. P., Li, J. S., Benjamin, D. K., Yoshizumi, T. T., Reiman, R. E., Frush, D. P., & Hill, K. D. (2014) · Circulation · doi:10.1161/circulationaha.113.005425 · Cited by 226
Korean Liver Cancer Study Group (KLCSG), & National Cancer Center, K. (. (2015) · Korean Journal of Radiology · doi:10.3348/kjr.2015.16.3.465 · Cited by 201
Multidetector CT in children: current concepts and dose reduction strategies
Nievelstein, R. A. J., van Dam, I. M., & van der Molen, A. J. (2010) · Pediatric Radiology · doi:10.1007/s00247-010-1714-7 · Cited by 201
Mendelsohn, D., Strelzow, J., Dea, N., Ford, N. L., Batke, J., Pennington, A., Yang, K., Ailon, T., Boyd, M., Dvorak, M., et al. (2016) · The Spine Journal · doi:10.1016/j.spinee.2015.11.020 · Cited by 200
Eisenberg, M. J., Afilalo, J., Lawler, P. R., Abrahamowicz, M., Richard, H., & Pilote, L. (2011) · Canadian Medical Association Journal · doi:10.1503/cmaj.100463 · Cited by 185
CT effective dose per dose length product using ICRP 103 weighting factors
Huda, W., Magill, D., & He, W. (2011) · Medical Physics · doi:10.1118/1.3544350 · Cited by 173
Einstein, A. J., Weiner, S. D., Bernheim, A., Kulon, M., Bokhari, S., Johnson, L. L., Moses, J. W., & Balter, S. (2010) · JAMA · doi:10.1001/jama.2010.1664 · Cited by 164
Han, B. K., Rigsby, C. K., Leipsic, J., Bardo, D., Abbara, S., Ghoshhajra, B., Lesser, J. R., Raman, S. V., Crean, A. M., Nicol, E. D., et al. (2015) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2015.07.007 · Cited by 158
Little, M. P., Wakeford, R., Borrego, D., French, B., Zablotska, L. B., Adams, M. J., Allodji, R., de Vathaire, F., Lee, C., Brenner, A. V., et al. (2018) · The Lancet Haematology · doi:10.1016/s2352-3026(18)30092-9 · Cited by 152
Cremonesi, M., Ferrari, M. E., Bodei, L., Chiesa, C., Sarnelli, A., Garibaldi, C., Pacilio, M., Strigari, L., Summers, P. E., Orecchia, R., et al. (2018) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-4044-x · Cited by 141
Risk of Brain Tumor Induction from Pediatric Head CT Procedures: A Systematic Literature Review
Sheppard, J. P., Nguyen, T., Alkhalid, Y., Beckett, J. S., Salamon, N., & Yang, I. (2018) · Brain Tumor Research and Treatment · doi:10.14791/btrt.2018.6.e4 · Cited by 90
Updated Australian diagnostic reference levels for adult CT
Lee, K. L., Beveridge, T., Sanagou, M., & Thomas, P. (2020) · Journal of Medical Radiation Sciences · doi:10.1002/jmrs.372 · Cited by 75
Franck, C., Vandevoorde, C., Goethals, I., Smeets, P., Achten, E., Verstraete, K., Thierens, H., & Bacher, K. (2016) · European Radiology · doi:10.1007/s00330-015-4091-7 · Cited by 43
The Million Person Study relevance to space exploration and Mars
Boice, J. D. (2022) · International Journal of Radiation Biology · doi:10.1080/09553002.2019.1589020 · Cited by 34
Effective radiation doses of CT examinations in Japan: a nationwide questionnaire-based study
Matsunaga, Y., Kawaguchi, A., Kobayashi, K., Kobayashi, M., Asada, Y., Minami, K., Suzuki, S., & Chida, K. (2016) · The British Journal of Radiology · doi:10.1259/bjr.20150671 · Cited by 29
Aoki, R., Iwasawa, T., Hagiwara, E., Komatsu, S., Utsunomiya, D., & Ogura, T. (2021) · Japanese Journal of Radiology · doi:10.1007/s11604-020-01085-2 · Cited by 26
Ehresmann, B., Burmeister, S., Wimmer-Schweingruber, R. F., & Reitz, G. (2011) · Journal of Geophysical Research: Space Physics · doi:10.1029/2011ja016616 · Cited by 26
A bespoke health risk assessment methodology for the radiation protection of astronauts
Walsh, L., Hafner, L., Straube, U., Ulanowski, A., Fogtman, A., Durante, M., Weerts, G., & Schneider, U. (2021) · Radiation and Environmental Biophysics · doi:10.1007/s00411-021-00910-0 · Cited by 23
Reducing Radiation, Revising Reference Levels
Miller, D. L., Vano, E., & Rehani, M. M. (2015) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2014.07.012 · Cited by 17
Practical recommendations for the application of DE 59/2013
Torresin, A., Evans, S., Lizio, D., Pierotti, L., Stasi, M., & Salerno, S. (2019) · La radiologia medica · doi:10.1007/s11547-019-01031-x · Cited by 17
Jasieniak, J., Kuchcińska, A., Podgórska, J., & Cieszanowski, A. (2023) · Polish Journal of Radiology · doi:10.5114/pjr.2023.124376 · Cited by 17
Relationships of radiation dose indices with body size indices in adult body computed tomography
Inoue, Y., Itoh, H., Nagahara, K., Hata, H., & Mitsui, K. (2023) · Tomography · doi:10.3390/tomography9040110 · Cited by 16
Xiao, Y., Ling, M., Liang, Z., Ding, J., Zhan, S., Hu, H., & Chen, B. (2021) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-021-02307-2 · Cited by 14
Rabus, H., Gómez-Ros, J. M., Villagrasa, C., Eakins, J., Vrba, T., Blideanu, V, Zankl, M., Tanner, R., Struelens, L., Brkić, H., et al. (2021) · Journal of Radiological Protection · doi:10.1088/1361-6498/abd914 · Cited by 13
Varghese, B., Kandanga, I., Puthussery, P., Vijayan, D., Babu, S. P. H., Aneesh, M. K., Noufal, M., Binu, E. V., Babu, A. C., James, S. M., et al. (2018) · Indian Journal of Radiology and Imaging · doi:10.4103/ijri.ijri_394_17 · Cited by 12
Johansen, A., Holm, S., Dall, B., Keller, S., Kristensen, J. L., Knudsen, G. M., & Hansen, H. D. (2019) · EJNMMI Research · doi:10.1186/s13550-019-0527-4 · Cited by 10
Alhujaili, S. F., Alshabibi, A. S., Alafer, F., Alrowaili, Z., Salah, H., Sulieman, A., Subahi, M., Al-Raddadi, K., & Abuzaid, M. (2024) · Diagnostics · doi:10.3390/diagnostics14242882 · Cited by 7
Metadata
- Authors
- Dixon, A. K.
- Venue
- Annals of the ICRP
- Publisher
- SAGE Publications
- Published
- 2007-03
- Volume
- 37
- Issue
- 1
- Pages
- 1-3
- ISSN
- 0146-6453 (ISSN-L)
- 1872-969X
- OpenAlex
- W2087044912
- Cited by
- 1,355
- References
- 1
- FWCI
- 30.78
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.