Guidelines to Study and Develop Soft Electrode Systems for Neural Stimulation
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Electrical stimulation of nervous structures is a widely used experimental and clinical method to probe neural circuits, perform diagnostics, or treat neurological disorders. The recent introduction of soft materials to design electrodes that conform to and mimic neural tissue led to neural interfaces with improved functionality and biointegration. The shift from stiff to soft electrode materials requires adaptation of the models and characterization methods to understand and predict electrode performance. This guideline aims at providing (1) an overview of the most common techniques to test soft electrodes in vitro and in vivo; (2) a step-by-step design of a complete study protocol, from the lab bench to in vivo experiments; (3) a case study illustrating the characterization of soft spinal electrodes in rodents; and (4) examples of how interpreting characterization data can inform experimental decisions. Comprehensive characterization is paramount to advancing soft neurotechnology that meets the requisites for long-term functionality in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Recent Advances in Flexible and Stretchable Bio‐Electronic Devices Integrated with Nanomaterials
Choi, S., Lee, H., Ghaffari, R., Hyeon, T., & Kim, D. (2016) · Advanced Materials · doi:10.1002/adma.201504150 · Cited by 1,104
Targeted neurotechnology restores walking in humans with spinal cord injury
Wagner, F. B., Mignardot, J.-B., Le Goff-Mignardot, C. G., Demesmaeker, R., Komi, S., Capogrosso, M., Rowald, A., Seáñez, I., Caban, M., Pirondini, E., et al. (2018) · Nature · doi:10.1038/s41586-018-0649-2 · Cited by 1,087
Self-citationElectronic dura mater for long-term multimodal neural interfaces
Minev, I. R., Musienko, P., Hirsch, A., Barraud, Q., Wenger, N., Moraud, E. M., Gandar, J., Capogrosso, M., Milekovic, T., Asboth, L., et al. (2015) · Science · doi:10.1126/science.1260318 · Cited by 1,082
Self-citationSoft and elastic hydrogel-based microelectronics for localized low-voltage neuromodulation
Liu, Y., Liu, J., Chen, S., Lei, T., Kim, Y., Niu, S., Wang, H., Wang, X., Foudeh, A. M., Tok, J. B.-H., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0335-6 · Cited by 811
Materials and technologies for soft implantable neuroprostheses
Lacour, S. P., Courtine, G., & Guck, J. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.63 · Cited by 738
Self-citationKozai, T. D. Y., Langhals, N. B., Patel, P. R., Deng, X., Zhang, H., Smith, K. L., Lahann, J., Kotov, N. A., & Kipke, D. R. (2012) · Nature Materials · doi:10.1038/nmat3468 · Cited by 721
Charge density and charge per phase as cofactors in neural injury induced by electrical stimulation
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102812 · Cited by 708
Revealing neuronal function through microelectrode array recordings
Obien, M. E. J., Deligkaris, K., Bullmann, T., Bakkum, D. J., & Frey, U. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00423 · Cited by 705
Recovery of Over-Ground Walking after Chronic Motor Complete Spinal Cord Injury
Angeli, C. A., Boakye, M., Morton, R. A., Vogt, J., Benton, K., Chen, Y., Ferreira, C. K., & Harkema, S. J. (2018) · New England Journal of Medicine · doi:10.1056/nejmoa1803588 · Cited by 670
Gill, M. L., Grahn, P. J., Calvert, J. S., Linde, M. B., Lavrov, I. A., Strommen, J. A., Beck, L. A., Sayenko, D. G., Van Straaten, M. G., Drubach, D. I., et al. (2018) · Nature Medicine · doi:10.1038/s41591-018-0175-7 · Cited by 574
A jump-start for electroceuticals
Famm, K., Litt, B., Tracey, K. J., Boyden, E. S., & Slaoui, M. (2013) · Nature · doi:10.1038/496159a · Cited by 554
A model of safe levels for electrical stimulation
Shannon, R. V. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.126616 · Cited by 526
A Computational Model for Epidural Electrical Stimulation of Spinal Sensorimotor Circuits
Capogrosso, M., Wenger, N., Raspopovic, S., Musienko, P., Beauparlant, J., Bassi Luciani, L., Courtine, G., & Micera, S. (2013) · The Journal of Neuroscience · doi:10.1523/jneurosci.1688-13.2013 · Cited by 435
Self-citationA MEMS-based flexible multichannel ECoG-electrode array
Rubehn, B., Bosman, C., Oostenveld, R., Fries, P., & Stieglitz, T. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/3/036003 · Cited by 387
Tissue damage thresholds during therapeutic electrical stimulation
Cogan, S. F., Ludwig, K. A., Welle, C. G., & Takmakov, P. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/021001 · Cited by 386
Progress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384
In vitro electrical properties for iridium oxide versus titanium nitride stimulating electrodes
Weiland, J. D., Anderson, D. J., & Humayun, M. S. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.805487 · Cited by 382
Wenger, N., Moraud, E. M., Gandar, J., Musienko, P., Capogrosso, M., Baud, L., Le Goff, C. G., Barraud, Q., Pavlova, N., Dominici, N., et al. (2016) · Nature Medicine · doi:10.1038/nm.4025 · Cited by 369
Self-citationMicromachined, Polyimide-Based Devices for Flexible Neural Interfaces
Stieglitz, T., Beutel, H., Schuettler, M., & Meyer, J.-U. (2000) · Biomedical Microdevices · doi:10.1023/a:1009955222114 · Cited by 343
Soft Materials in Neuroengineering for Hard Problems in Neuroscience
Jeong, J.-W., Shin, G., Park, S. I., Yu, K. J., Xu, L., & Rogers, J. A. (2015) · Neuron · doi:10.1016/j.neuron.2014.12.035 · Cited by 333
High‐Density Stretchable Electrode Grids for Chronic Neural Recording
Tybrandt, K., Khodagholy, D., Dielacher, B., Stauffer, F., Renz, A. F., Buzsáki, G., & Vörös, J. (2018) · Advanced Materials · doi:10.1002/adma.201706520 · Cited by 286
Mechanically-compliant intracortical implants reduce the neuroinflammatory response
Nguyen, J. K., Park, D. J., Skousen, J. L., Hess-Dunning, A. E., Tyler, D. J., Rowan, S. J., Weder, C., & Capadona, J. R. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/056014 · Cited by 274
A carbon-fiber electrode array for long-term neural recording
Guitchounts, G., Markowitz, J. E., Liberti, W. A., & Gardner, T. J. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/046016 · Cited by 224
Over-pulsing degrades activated iridium oxide films used for intracortical neural stimulation
Cogan, S. F., Guzelian, A. A., Agnew, W. F., Yuen, T. G. H., & McCreery, D. B. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.02.019 · Cited by 210
Chronic in vivo stability assessment of carbon fiber microelectrode arrays
Patel, P. R., Zhang, H., Robbins, M. T., Nofar, J. B., Marshall, S. P., Kobylarek, M. J., Kozai, T. D. Y., Kotov, N. A., & Chestek, C. A. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/066002 · Cited by 204
Comparison of neural damage induced by electrical stimulation with faradaic and capacitor electrodes
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. A. (1988) · Annals of Biomedical Engineering · doi:10.1007/bf02368010 · Cited by 163
Cogan, S. F., Troyk, P. R., Ehrlich, J., & Plante, T. D. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851503 · Cited by 162
Rapid prototyping of soft bioelectronic implants for use as neuromuscular interfaces
Afanasenkau, D., Kalinina, D., Lyakhovetskii, V., Tondera, C., Gorsky, O., Moosavi, S., Pavlova, N., Merkulyeva, N., Kalueff, A. V., Minev, I. R., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00615-7 · Cited by 148
Cogan, S. F., Troyk, P. R., Ehrlich, J., Plante, T. D., & Detlefsen, D. E. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.862572 · Cited by 138
Stretchable Polymeric Multielectrode Array for Conformal Neural Interfacing
Guo, L., Ma, M., Zhang, N., Langer, R., & Anderson, D. G. (2014) · Advanced Materials · doi:10.1002/adma.201304140 · Cited by 128
Conformable hybrid systems for implantable bioelectronic interfaces
Fallegger, F., Schiavone, G., & Lacour, S. P. (2020) · Advanced Materials · doi:10.1002/adma.201903904 · Cited by 113
Self-citationAgnew, W. F., Yuen, T. G. H., & McCreery, D. B. (1983) · Experimental Neurology · doi:10.1016/0014-4886(83)90221-2 · Cited by 96
Pena, A. E., Kuntaegowdanahalli, S. S., Abbas, J. J., Patrick, J., Horch, K. W., & Jung, R. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa814d · Cited by 22
Cited by
Skin-inspired soft bioelectronic materials, devices and systems
Zhao, C., Park, J., Root, S. E., & Bao, Z. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00194-1 · Cited by 408
Electronics with shape actuation for minimally invasive spinal cord stimulation
Woodington, B. J., Curto, V. F., Yu, Y.-L., Martínez-Domínguez, H., Coles, L., Malliaras, G. G., Proctor, C. M., & Barone, D. G. (2021) · Science Advances · doi:10.1126/sciadv.abg7833 · Cited by 75
“CIC measurements were carried out using a three-electrode system as reported in the literature (28, 29).”
MethodBiomedical Implants with Charge‐Transfer Monitoring and Regulating Abilities
Wang, D., Tan, J., Zhu, H., Mei, Y., & Liu, X. (2021) · Advanced Science · doi:10.1002/advs.202004393 · Cited by 49
Transient neurovascular interface for minimally invasive neural recording and stimulation
Fanelli, A., Ferlauto, L., Zollinger, E. G., Brina, O., Reymond, P., Machi, P., & Ghezzi, D. (2022) · Advanced Materials Technologies · doi:10.1002/admt.202100176 · Cited by 22
Metadata
- Authors
- Schiavone, G., Kang, X., Fallegger, F., Gandar, J., Courtine, G., & Lacour, S. P.
- Venue
- Neuron
- Publisher
- Elsevier BV
- Published
- 2020-10
- Volume
- 108
- Issue
- 2
- Pages
- 238-258
- ISSN
- 0896-6273 (ISSN-L)
- OpenAlex
- W3096152429
- Cited by
- 121
- References
- 35
- FWCI
- 4.79
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.