Cited by 229Neuroscience and Neural EngineeringRetinal Diseases and TreatmentsRetinal Development and Disorders

The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.

Photovoltaic Restoration of Central Vision in Atrophic Age-Related Macular Degeneration

Open access
Palanker, Daniel, Le Mer, Yannick, Mohand-Said, Saddek, Muqit, Mahiul, Sahel, Jose A.·2020·Ophthalmology

Abstract

PURPOSE: Loss of photoreceptors in atrophic age-related macular degeneration results in severe visual impairment, although some peripheral vision is retained. To restore central vision without compromising the residual peripheral field, we developed a wireless photovoltaic retinal implant (PRIMA; Pixium Vision, Paris, France) in which pixels convert images projected from video glasses using near-infrared light into electric current to stimulate the nearby inner retinal neurons. DESIGN: We carried out a first-in-human clinical trial to test the safety and efficacy of the prosthesis in patients with geographic atrophy (ClinicalTrials.gov identifier, NCT03333954). PARTICIPANTS: Five patients with geographic atrophy zone of at least 3 optic disc diameters, no foveal light perception, and best-corrected visual acuity of 20/400 to 20/1000 in the worse-seeing study eye. METHODS: The 2-mm wide, 30-μm thick chip, containing 378 pixels (each 100 μm in diameter), was implanted subretinally in the area of atrophy (absolute scotoma). MAIN OUTCOME MEASURES: Anatomic outcomes were assessed with fundus photography and OCT for up to 12 months of follow-up. Prosthetic vision was assessed by mapping light perception, bar orientation, letter recognition, and Landolt C acuity. RESULTS: In all patients, the prosthesis was implanted successfully under the macula, although in 2 patients, it was implanted in unintended locations: within the choroid and off center by 2 mm. All 5 patients could perceive white-yellow prosthetic visual patterns with adjustable brightness in the previous scotomata. The 3 with optimal placement of the implant demonstrated prosthetic acuity of 20/460 to 20/550, and the patient with the off-center implant demonstrated 20/800 acuity. Residual natural acuity did not decrease after implantation in any patient. CONCLUSIONS: Implantation of the PRIMA did not decrease the residual natural acuity, and it restored visual sensitivity in the former scotoma in each of the 5 patients. In 3 patients with the proper placement of the chip, prosthetic visual acuity was only 10% to 30% less than the level expected from the pixel pitch (20/420). Therefore, the use of optical or electronic magnification in the glasses as well as smaller pixels in future implants may improve visual acuity even further.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ophtha.2020.02.024

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Flagged first, then by citations

Show all 36 references

Cited by

Sorted by citations

Metadata

Authors
Palanker, D., Le Mer, Y., Mohand-Said, S., Muqit, M., & Sahel, J. A.
Affiliations
  • Stanford University (US)
  • Moorfields Eye Hospital NHS Foundation Trust (GB)
Corresponding author
Palanker, Daniel
Venue
Ophthalmology
Publisher
Elsevier BV
Published
2020-08
Volume
127
Issue
8
Pages
1097-1104
ISSN
0161-6420 (ISSN-L)
OpenAlex
W3006860701
Cited by
227
References
36
Citations by year
2026: 31 · 2025: 29 · 2024: 26 · 2023: 37 · 2022: 37 · 2021: 44 · 2020: 22
FWCI
16.03
Type
journal article
Language
en
Open access
Locations
  • Ophthalmology (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
  • UCL Discovery (University College London) (submittedVersion)
Funders
National Institutes of Health
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Health Sciences › Medicine › Ophthalmology › Retinal Diseases and Treatments
  • Health Sciences › Medicine › Ophthalmology › Retinal Development and Disorders
Keywords
dry age-related macular degeneration, geographic atrophy, PRIMA, subretinal implantation, scotoma, photoreceptor loss, implant safety and efficacy, pixel pitch
MeSH terms
Electrodes, Implanted, Feasibility Studies, Female, Humans, Macula Lutea, Macular Degeneration, Male, Middle Aged, Visual Perception, Recovery of Function, Tomography, Optical Coherence, Visual Prosthesis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review