STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 1,501–1,600 of 47,868
Bonomi, A. G., Plasqui, G., Goris, A. H. C., & Westerterp, K. R. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00150.2009 · Cited by 196
Rapid flow cytometric test for the diagnosis of membrane cytoskeleton-associated haemolytic anaemia
King, M., Behrens, J., Rogers, C. A., Flynn, C., Greenwood, D. R., & Chambers, K. (2000) · British Journal of Haematology · doi:10.1046/j.1365-2141.2000.02416.x · Cited by 195
Marquardt, L., Kuker, W., Chandratheva, A., Geraghty, O., & Rothwell, P. M. (2008) · Brain · doi:10.1093/brain/awp026 · Cited by 196
Lanyon, P., O'Reilly, S., Jones, A., & Doherty, M. (1998) · Annals of the Rheumatic Diseases · doi:10.1136/ard.57.10.595 · Cited by 195
Validation of the GT3X ActiGraph in children and comparison with the GT1M ActiGraph
Hänggi, J. M., Phillips, L. R. S., & Rowlands, A. V. (2013) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2012.05.012 · Cited by 196
Villegas, R., Yang, G., Liu, D., Xiang, Y.-B., Cai, H., Zheng, W., & Ou Shu, X. (2007) · British Journal of Nutrition · doi:10.1017/s0007114507669189 · Cited by 195
Cognition in the days following concussion: comparison of symptomatic versus asymptomatic athletes
Collie, A. (2006) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2005.073155 · Cited by 195
Kamper, P., Bendix, K., Hamilton-Dutoit, S., Honore, B., Nyengaard, J. R., & d'Amore, F. (2011) · Haematologica · doi:10.3324/haematol.2010.031542 · Cited by 196
Slower Postnatal Growth Is Associated with Delayed Cerebral Cortical Maturation in Preterm Newborns
Vinall, J., Grunau, R. E., Brant, R., Chau, V., Poskitt, K. J., Synnes, A. R., & Miller, S. P. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3004666 · Cited by 198
Baumgartner, H., Khan, S. S., DeRobertis, M. A., Czer, L. S. C., & Maurer, G. (1990) · Circulation · doi:10.1161/01.cir.82.4.1467 · Cited by 196
Six-compartment body composition model: Inter-method comparisons of total body fat measurement
Wang, Z., Deurenberg, P., Guo, S., Pietrobelli, A., Wang, J., Jr, R. P., & Heymsfield, S. (1998) · International Journal of Obesity · doi:10.1038/sj.ijo.0800590 · Cited by 195
Dermatology quality of life scales -a measure of the impact of skin diseases
MORGAN, M., McCREEDY, R., SIMPSON, J., & HAY, R. J. (1997) · British Journal of Dermatology · doi:10.1046/j.1365-2133.1997.d01-1169.x · Cited by 197
Jander, S., Sitzer, M., Schumann, R., Schroeter, M., Siebler, M., Steinmetz, H., & Stoll, G. (1998) · Stroke · doi:10.1161/01.str.29.8.1625 · Cited by 195
Silva, A. T., Bayston, K. F., & Cohen, J. (1990) · Journal of Infectious Diseases · doi:10.1093/infdis/162.2.421 · Cited by 197
Drake, R., Haddock, G., Tarrier, N., Bentall, R., & Lewis, S. (2007) · Schizophrenia Research · doi:10.1016/j.schres.2006.04.024 · Cited by 194
Greupner, J., Zimmermann, E., Grohmann, A., Dübel, H.-P., Althoff, T., Borges, A. C., Rutsch, W., Schlattmann, P., Hamm, B., & Dewey, M. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.01.046 · Cited by 193
Finak, G., Frelinger, J., Jiang, W., Newell, E. W., Ramey, J., Davis, M. M., Kalams, S. A., De Rosa, S. C., & Gottardo, R. (2014) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1003806 · Cited by 197
Shayegi, N., Kramer, M., Bornhäuser, M., Schaich, M., Schetelig, J., Platzbecker, U., Röllig, C., Heiderich, C., Landt, O., Ehninger, G., et al. (2013) · Blood · doi:10.1182/blood-2012-10-461749 · Cited by 196
Ylinen, J., Salo, P., Nykänen, M., Kautiainen, H., & Häkkinen, A. (2004) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2003.09.018 · Cited by 192
Ventilatory and metabolic adaptations to walking and cycling in patients with COPD
Palange, P., Forte, S., Onorati, P., Manfredi, F., Serra, P., & Carlone, S. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.88.5.1715 · Cited by 194
Zammit, G. V., Menz, H. B., & Munteanu, S. E. (2010) · Journal of Foot and Ankle Research · doi:10.1186/1757-1146-3-11 · Cited by 224
Methodological issues in studying the epidemiology of mild to moderate chronic renal insufficiency
Hsu, C.-Y., Chertow, G. M., & Curhan, G. C. (2002) · Kidney International · doi:10.1046/j.1523-1755.2002.00299.x · Cited by 196
ECG-Gated Three-dimensional Intravascular Ultrasound
von Birgelen, C., de Vrey, E. A., Mintz, G. S., Nicosia, A., Bruining, N., Li, W., Slager, C. J., Roelandt, J. R. T. C., Serruys, P. W. J. C., & de Feyter, P. J. (1997) · Circulation · doi:10.1161/01.cir.96.9.2944 · Cited by 194
Mehta, S., Bastero‐Caballero, R. F., Sun, Y., Zhu, R., Murphy, D. K., Hardas, B., & Koch, G. (2018) · Statistics in Medicine · doi:10.1002/sim.7679 · Cited by 193
International Council for Standardization in Haematology, W. G., Briggs, C., Culp, N., Davis, B., d'Onofrio, G., Zini, G., Machin, S. J., & the International Council for Standardization of Haematology (2014) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12201 · Cited by 185
Evaluation of Fatigue Scales in Stroke Patients
Mead, G., Lynch, J., Greig, C., Young, A., Lewis, S., & Sharpe, M. (2007) · Stroke · doi:10.1161/strokeaha.106.478941 · Cited by 190
Exercise-Induced Changes in Degenerative Mitral Regurgitation
Magne, J., Lancellotti, P., & Piérard, L. A. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.12.073 · Cited by 194
Amato, M., Montorsi, P., Ravani, A., Oldani, E., Galli, S., Ravagnani, P. M., Tremoli, E., & Baldassarre, D. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm244 · Cited by 194
Improving Doctors' Understanding of Statistics
Altman, D. G., & Bland, J. M. (1991) · Journal of the Royal Statistical Society. Series A (Statistics in Society) · doi:10.2307/2983040 · Cited by 195
Self-citationCohen-Solal, A., Laperche, T., Morvan, D., Geneves, M., Caviezel, B., & Gourgon, R. (1995) · Circulation · doi:10.1161/01.cir.91.12.2924 · Cited by 194
Hong, C., Becker, C. R., Schoepf, U. J., Ohnesorge, B., Bruening, R., & Reiser, M. F. (2002) · Radiology · doi:10.1148/radiol.2232010919 · Cited by 193
Ryan, T. E., Southern, W. M., Reynolds, M. A., & McCully, K. K. (2013) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00835.2013 · Cited by 192
Validation of the revised Schwartz estimating equation in a predominantly non-CKD population
Staples, A. O., LeBlond, R., Watkins, S. L., Wong, C. S., & Brandt, J. R. (2010) · Pediatric Nephrology · doi:10.1007/s00467-010-1598-7 · Cited by 192
The Feasibility of Ultrasound to Assess Subglottic Diameter
Lakhal, K., Delplace, X., Cottier, J., Tranquart, F., Sauvagnac, X., Mercier, C., Fusciardi, J., & Laffon, M. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000260136.53694.fe · Cited by 192
Effect of Monitor Placement and of Activity Setting on the MTI Accelerometer Output
YNGVE, A., NILSSON, A., SJ??STR??M, M., & EKELUND, U. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000048829.75758.a0 · Cited by 192
Comparison Insight Bone Measurements by Histomorphometry and μCT
Chappard, D., Retailleau-Gaborit, N., Legrand, E., Baslé, M. F., & Audran, M. (2005) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.050205 · Cited by 194
Renker, M., Schoepf, U. J., Wang, R., Meinel, F. G., Rier, J. D., Bayer, R. R., Möllmann, H., Hamm, C. W., Steinberg, D. H., & Baumann, S. (2014) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2014.07.064 · Cited by 191
Magnetic resonance to assess the aortic valve area in aortic stenosis
John, A. S., Dill, T., Brandt, R. R., Rau, M., Ricken, W., Bachmann, G., & Hamm, C. W. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00707-1 · Cited by 192
Agreement between arterial and central venous values for pH, bicarbonate, base excess, and lactate
Middleton, P., Kelly, A.-M., Brown, J., & Robertson, M. (2006) · Emergency Medicine Journal · doi:10.1136/emj.2006.035915 · Cited by 192
Longitudinal strain quantitates regional right ventricular contractile function
Jamal, F., Bergerot, C., Argaud, L., Loufouat, J., & Ovize, M. (2003) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00218.2003 · Cited by 193
Ionasec, R. I., Voigt, I., Georgescu, B., Wang, Y., Houle, H., Vega-Higuera, F., Navab, N., & Comaniciu, D. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2048756 · Cited by 194
A New Method for Predicting Recovery After Stroke
Tilling, K., Sterne, J. A. C., Rudd, A. G., Glass, T. A., Wityk, R. J., & Wolfe, C. D. A. (2001) · Stroke · doi:10.1161/hs1201.099413 · Cited by 195
Test Variability of the QuantiFERON-TB Gold In-Tube Assay in Clinical Practice
Metcalfe, J. Z., Cattamanchi, A., McCulloch, C. E., Lew, J. D., Ha, N. P., & Graviss, E. A. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201203-0430oc · Cited by 191
Comparison of Different Diastolic Resting Indexes to iFR
Veer, M. V. ’., Pijls, N. H. J., Hennigan, B., Watkins, S., Ali, Z. A., Bruyne, B. D., Zimmermann, F. M., van Nunen, L. X., Barbato, E., Berry, C., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.10.066 · Cited by 192
Villemain, O., Correia, M., Mousseaux, E., Baranger, J., Zarka, S., Podetti, I., Soulat, G., Damy, T., Hagège, A., Tanter, M., et al. (2019) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2018.02.002 · Cited by 190
Wang, G., Liu, X., Shen, J., Wang, C., Li, Z., Ye, L., Wu, X., Chen, T., Wang, K., Zhang, X., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00704-1 · Cited by 190
Imaging with electricity: Report of the European Concerted Action on Impedance Tomography
Boone, K., Barber, D., & Brown, B. (1997) · Journal of Medical Engineering & Technology · doi:10.3109/03091909709070013 · Cited by 192
Powers, J. H., Patrick, D. L., Walton, M. K., Marquis, P., Cano, S., Hobart, J., Isaac, M., Vamvakas, S., Slagle, A., Molsen, E., et al. (2017) · Value in Health · doi:10.1016/j.jval.2016.11.005 · Cited by 191
Repeatability and reproducibility of corneal thickness measurements by optical coherence tomography.
Muscat, S., McKay, N., Parks, S., Kemp, E., & Keating, D. (2002) · PubMed · Cited by 191
Catalogue of Human Tissue Optical Properties at Terahertz Frequencies
Fitzgerald, A. J., Berry, E., Zinov'ev, N. N., Homer-Vanniasinkam, S., Miles, R. E., Chamberlain, J. M., & Smith, M. A. (2003) · Journal of Biological Physics · doi:10.1023/a:1024428406218 · Cited by 192
Clinical Comparison of the Icare Tonometer and Goldmann Applanation Tonometry
Pakrou, N., Gray, T., Mills, R., Landers, J., & Craig, J. (2008) · Journal of Glaucoma · doi:10.1097/ijg.0b013e318133fb32 · Cited by 189
Vinereanu, D., Nicolaides, E., Tweddel, A. C., & Fraser, A. G. (2005) · European Journal of Heart Failure · doi:10.1016/j.ejheart.2005.02.003 · Cited by 195
Validity of physical activity monitors in adults participating in free-living activities
Berntsen, S., Hageberg, R., Aandstad, A., Mowinckel, P., Anderssen, S. A., Carlsen, K.-H., & Andersen, L. B. (2010) · British Journal of Sports Medicine · doi:10.1136/bjsm.2008.048868 · Cited by 191
Validation of the Spanish Version of the Neck Disability Index
Andrade Ortega, J. A., Delgado Martínez, A. D., & Ruiz, R. A. (2010) · Spine · doi:10.1097/brs.0b013e3181afea5d · Cited by 190
Antzelevitch, C., Brugada, P., Brugada, J., Brugada, R., Towbin, J. A., & Nademanee, K. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00310-3 · Cited by 196
Pannekeet, M. M., Imholz, A. L. T., Struijk, D. G., Koomen, G. C. M., Langedijk, M. J., Schouten, N., de Waart, R., Hiralall, J., & Krediet, R. T. (1995) · Kidney International · doi:10.1038/ki.1995.363 · Cited by 193
Hundley, W. G., Li, H. F., Lange, R. A., Pfeifer, D. P., Meshack, B. M., Willard, J. E., Landau, C., Willett, D. L., Hillis, L. D., & Peshock, R. M. (1995) · Circulation · doi:10.1161/01.cir.91.12.2955 · Cited by 191
Lactate Production by the Lungs in Acute Lung Injury
DE BACKER, D., CRETEUR, J., ZHANG, H., NORRENBERG, M., & VINCENT, J.-L. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.156.4.9701048 · Cited by 190
Auger, J. (2000) · Human Reproduction · doi:10.1093/humrep/15.11.2360 · Cited by 191
Bratteby, L.-E., Sandhagen, B., Fan, H., & Samuelson, G. (1997) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1600449 · Cited by 190
An evaluation of automated methods for measurement of serum 25-hydroxyvitamin D
Wagner, D., Hanwell, H. E. C., & Vieth, R. (2009) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2009.07.013 · Cited by 191
A New Method of 3-D Cephalometry Part I: The Anatomic Cartesian 3-D Reference System
Swennen, G. R. J., Schutyser, F., Barth, E.-L., De Groeve, P., & De Mey, A. (2006) · Journal of Craniofacial Surgery · doi:10.1097/00001665-200603000-00019 · Cited by 193
Remote Measurements of Heart and Respiration Rates for Telemedicine
Zhao, F., Li, M., Qian, Y., & Tsien, J. Z. (2013) · PLoS ONE · doi:10.1371/journal.pone.0071384 · Cited by 189
Inter-rater reliability study of the modified Oxford Grading Scale and the Peritron manometer
Ferreira, C. H. J., Barbosa, P. B., Souza, F. D. O., Antônio, F. I., Franco, M. M., & Bø, K. (2011) · Physiotherapy · doi:10.1016/j.physio.2010.06.007 · Cited by 190
Kelly, A. M., Leslie, P., Beale, T., Payten, C., & Drinnan, M. J. (2006) · Clinical Otolaryngology · doi:10.1111/j.1749-4486.2006.01292.x · Cited by 188
Growth of C57Bl/6 Mice and the Material and Mechanical Properties of Cortical Bone from the Tibia
Somerville, J. M., Aspden, R. M., Armour, K. E., Armour, K. J., & Reid, D. M. (2004) · Calcified Tissue International · doi:10.1007/s00223-003-0101-x · Cited by 189
Tutschek, B., Braun, T., Chantraine, F., & Henrich, W. (2010) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2010.02775.x · Cited by 190
Suffoletto, B., Callaway, C., Kristan, J., Kraemer, K., & Clark, D. B. (2012) · Alcoholism: Clinical and Experimental Research · doi:10.1111/j.1530-0277.2011.01646.x · Cited by 191
Kelly, P., Fitzsimons, C., & Baker, G. (2016) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-016-0351-4 · Cited by 190
Symons, R., Reich, D. S., Bagheri, M., Cork, T. E., Krauss, B., Ulzheimer, S., Kappler, S., Bluemke, D. A., & Pourmorteza, A. (2018) · Investigative Radiology · doi:10.1097/rli.0000000000000418 · Cited by 191
CARE Consortium Investigators, Broglio, S. P., Katz, B. P., Zhao, S., McCrea, M., & McAllister, T. (2018) · Sports Medicine · doi:10.1007/s40279-017-0813-0 · Cited by 187
Leeuwen, M. A. V., van Rijswijk, M. H., Sluiter, W. J., van Riel, P. L., Kuper, I. H., van de Putte, L. B., Pepys, M. B., & Limburg, P. C. (1997) · PubMed · Cited by 190
OLSON, L., COLE, M., & AMBROGETTI, A. (1998) · Journal of Sleep Research · doi:10.1046/j.1365-2869.1998.00123.x · Cited by 193
The Use of Significant Others as Proxy Raters of the Quality of Life of Patients with Brain Cancer
Sneeuw, K. C. A., Aaronson, N. K., Osoba, D., Muller, M. J., Hsu, M.-A., Yung, W. K. A., Brada, M., & Newlands, E. S. (1997) · Medical Care · doi:10.1097/00005650-199705000-00006 · Cited by 192
Validity and reproducibility of a web-based, self-administered food frequency questionnaire
Labonté, M.-È., Cyr, A., Baril-Gravel, L., Royer, M.-M., & Lamarche, B. (2012) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2011.163 · Cited by 189
Schuster, A., Stahnke, V., Unterberg‐Buchwald, C., Kowallick, J. T., Lamata, P., Steinmetz, M., Kutty, S., Faßhauer, M., Staab, W., Sohns, J. M. S., et al. (2015) · Clinical Radiology · doi:10.1016/j.crad.2015.05.006 · Cited by 189
Reproducibility of facial soft tissue landmarks on 3D laser‐scanned facial images
Toma, A., Zhurov, A., Playle, R., Ong, E., & Richmond, S. (2009) · Orthodontics & Craniofacial Research · doi:10.1111/j.1601-6343.2008.01435.x · Cited by 187
Noninvasive uterine electromyography for prediction of preterm delivery
Lucovnik, M., Maner, W. L., Chambliss, L. R., Blumrick, R., Balducci, J., Novak-Antolic, Z., & Garfield, R. E. (2011) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2010.09.024 · Cited by 187
Guiu, B., Petit, J.-M., Loffroy, R., Ben Salem, D., Aho, S., Masson, D., Hillon, P., Krause, D., & Cercueil, J.-P. (2009) · Radiology · doi:10.1148/radiol.2493080217 · Cited by 193
Doors, M., Tahzib, N. G., Eggink, F. A. G. J., Berendschot, T. T. J. M., Webers, C. A. B., & Nuijts, R. M. M. A. (2009) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2009.06.031 · Cited by 189
Japanese version of the Oral Health Impact Profile (OHIP‐J)
YAMAZAKI, M., INUKAI, M., BABA, K., & JOHN, M. T. (2007) · Journal of Oral Rehabilitation · doi:10.1111/j.1365-2842.2006.01693.x · Cited by 187
emPHasis-10: development of a health-related quality of life measure in pulmonary hypertension
Yorke, J., Corris, P., Gaine, S., Gibbs, J. S. R., Kiely, D. G., Harries, C., Pollock, V., & Armstrong, I. (2014) · European Respiratory Journal · doi:10.1183/09031936.00127113 · Cited by 188
Fortin, M., & Battié, M. C. (2012) · Physical Therapy · doi:10.2522/ptj.20110380 · Cited by 187
Motion-tolerant magnetic earring sensor and wireless earpiece for wearable photoplethysmography
Poh, M.-Z., Swenson, N. C., & Picard, R. W. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2042607 · Cited by 189
Bragadottir, G., Redfors, B., & Ricksten, S.-E. (2013) · Critical Care · doi:10.1186/cc12777 · Cited by 188
Comparison of OPS imaging and conventional capillary microscopy to study the human microcirculation
Mathura, K. R., Vollebregt, K. C., Boer, K., De Graaff, J. C., Ubbink, D. T., & Ince, C. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.91.1.74 · Cited by 195
Ozier, Y., Ankri, A., Fléron, M.-H., Leroux, G., Samama, C. M., & Toulon, P. (2009) · Thrombosis and Haemostasis · doi:10.1160/th08-06-0383 · Cited by 192
Schneider, C., Malisius, R., Krause, K., Lampe, F., Bahlmann, E., Boczor, S., Antz, M., Ernst, S., & Kuck, K.-H. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn168 · Cited by 189
Equations to Estimate Creatinine Excretion Rate: The CKD Epidemiology Collaboration
Ix, J. H., Wassel, C. L., Stevens, L. A., Beck, G. J., Froissart, M., Navis, G., Rodby, R., Torres, V. E., Zhang, Y. (., Greene, T., et al. (2011) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.05030610 · Cited by 191
Imagama, S., Matsuyama, Y., Yukawa, Y., Kawakami, N., Kamiya, M., Kanemura, T., Ishiguro, N., Imagama, Ñ. S., & Matsuyama, N. (2010) · Cited by 189
Lange, T., Kopkow, C., Lützner, J., Günther, K.-P., Gravius, S., Scharf, H.-P., Stöve, J., Wagner, R., & Schmitt, J. (2020) · BMC Medical Research Methodology · doi:10.1186/s12874-020-0912-8 · Cited by 184
Towards standardizing retinal optical coherence tomography angiography: a review
Sampson, D. M., Dubis, A. M., Chen, F. K., Zawadzki, R. J., & Sampson, D. D. (2022) · Light: Science & Applications · doi:10.1038/s41377-022-00740-9 · Cited by 179
The effects of aging on the cutaneous microvasculature
Kelly, R. I., Pearse, R., Bull, R. H., Leveque, J.-L., de Rigal, J., & Mortimer, P. S. (1995) · Journal of the American Academy of Dermatology · doi:10.1016/0190-9622(95)91812-4 · Cited by 188
Gaspari, F., Ferrari, S., Stucchi, N., Centemeri, E., Carrara, F., Pellegrino, M., Gherardi, G., Gotti, E., Segoloni, G., Salvadori, M., et al. (2004) · American Journal of Transplantation · doi:10.1111/j.1600-6143.2004.00579.x · Cited by 192
Amodio, P., Wenin, H., Del Piccolo, F., Mapelli, D., Montagnese, S., Pellegrini, A., Musto, C., Gatta, A., & Umiltà, C. (2002) · Aging Clinical and Experimental Research · doi:10.1007/bf03324425 · Cited by 188
Is there evidence for an age-related reduction in metabolic rate?
Piers, L. S., Soares, M. J., McCormack, L. M., & O’Dea, K. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.6.2196 · Cited by 189
Morgan, M. Y., Madden, A. M., Soulsby, C. T., & Morris, R. W. (2006) · Hepatology · doi:10.1002/hep.21358 · Cited by 188
Real-time gait event detection using wearable sensors
Hanlon, M., & Anderson, R. (2009) · Gait & Posture · doi:10.1016/j.gaitpost.2009.07.128 · Cited by 187
Motion-Resistant Remote Imaging Photoplethysmography Based on the Optical Properties of Skin
Feng, L., Po, L.-M., Xu, X., Li, Y., & Ma, R. (2015) · IEEE Transactions on Circuits and Systems for Video Technology · doi:10.1109/tcsvt.2014.2364415 · Cited by 186
Pritchett, L. C., Ulibarri, C., Roberts, M. C., Schneider, R. K., & Sellon, D. C. (2003) · Applied Animal Behaviour Science · doi:10.1016/s0168-1591(02)00205-8 · Cited by 188
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.