STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 1,101–1,200 of 47,868
Detecting axon damage in spinal cord from a mouse model of multiple sclerosis
Kim, J. H., Budde, M. D., Liang, H.-F., Klein, R. S., Russell, J. H., Cross, A. H., & Song, S.-K. (2006) · Neurobiology of Disease · doi:10.1016/j.nbd.2005.09.009 · Cited by 235
Neurite imaging reveals microstructural variations in human cerebral cortical gray matter
Fukutomi, H., Glasser, M. F., Zhang, H., Autio, J. A., Coalson, T. S., Okada, T., Togashi, K., Van Essen, D. C., & Hayashi, T. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.02.017 · Cited by 234
Evaluation of repeatability of pressure algometry on the neck muscles for clinical use
Ylinen, J., Nykänen, M., Kautiainen, H., & Häkkinen, A. (2007) · Manual Therapy · doi:10.1016/j.math.2006.06.010 · Cited by 237
Quantitative assessment of pleural effusion in critically ill patients by means of ultrasonography*
Vignon, P., Chastagner, C., Berkane, V., Chardac, E., François, B., Normand, S., Bonnivard, M., Clavel, M., Pichon, N., Preux, P., et al. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000171532.02639.08 · Cited by 234
Measurement of fat mass using DEXA: a validation study in elderly adults
Salamone, L. M., Fuerst, T., Visser, M., Kern, M., Lang, T., Dockrell, M., Cauley, J. A., Nevitt, M., Tylavsky, F., & Lohman, T. G. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.89.1.345 · Cited by 233
Novel method for high-throughput phenotyping of sleep in mice
Pack, A. I., Galante, R. J., Maislin, G., Cater, J., Metaxas, D., Lu, S., Zhang, L., Smith, R. V., Kay, T., Lian, J., et al. (2007) · Physiological Genomics · doi:10.1152/physiolgenomics.00139.2006 · Cited by 235
Dekkers, J. C., van Wier, M. F., Hendriksen, I. J., Twisk, J. W., & van Mechelen, W. (2008) · BMC Medical Research Methodology · doi:10.1186/1471-2288-8-69 · Cited by 237
Streppel, M. T., de Vries, J. H., Meijboom, S., Beekman, M., de Craen, A. J., Slagboom, P. E., & Feskens, E. J. (2013) · Nutrition Journal · doi:10.1186/1475-2891-12-75 · Cited by 236
Josephs, L. K., Gregg, I., Mullee, M. A., & Holgate, S. T. (1989) · American Review of Respiratory Disease · doi:10.1164/ajrccm/140.2.350 · Cited by 234
Obradovic, M., Lal, A., & Liedgens, H. (2013) · Health and Quality of Life Outcomes · doi:10.1186/1477-7525-11-110 · Cited by 233
High-Speed Myocardial Perfusion Imaging
Sharir, T., Ben-Haim, S., Merzon, K., Prochorov, V., Dickman, D., Ben-Haim, S., & Berman, D. S. (2008) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2007.12.004 · Cited by 234
Place, N., Maffiuletti, N. A., Martin, A., & Lepers, R. (2007) · Muscle & Nerve · doi:10.1002/mus.20714 · Cited by 230
Arterial Mechanical Changes in Children With Familial Hypercholesterolemia
Aggoun, Y., Bonnet, D., Sidi, D., Girardet, J. P., Brucker, E., Polak, M., Safar, M. E., & Levy, B. I. (2000) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.20.9.2070 · Cited by 232
ESSICK, G., CHOPRA, A., GUEST, S., & MCGLONE, F. (2003) · Physiology & Behavior · doi:10.1016/j.physbeh.2003.08.007 · Cited by 236
Zook, J. M., Long, S. E., Cleveland, D., Geronimo, C. L. A., & MacCuspie, R. I. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-5266-y · Cited by 233
Ramiro, S., Stolwijk, C., van Tubergen, A. M., van der Heijde, D. M. F. M., Dougados, M., den Bosch, F. E. V., & Landewé, R. (2013) · Annals of the Rheumatic Diseases · doi:10.1136/annrheumdis-2013-204055 · Cited by 233
Zinkhan, M., Berger, K., Hense, S., Nagel, M., Obst, A., Koch, B., Penzel, T., Fietze, I., Ahrens, W., Young, P., et al. (2014) · Sleep Medicine · doi:10.1016/j.sleep.2014.04.015 · Cited by 232
Quality assessment and authentication of virgin olive oil by NMR spectroscopy: A critical review
Dais, P., & Hatzakis, E. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.12.003 · Cited by 231
C-reactive protein is associated with renal function abnormalities in a non-diabetic population
Stuveling, E. M., Hillege, H. L., Bakker, S. J. L., Gans, R. O. B., de Jong, P. E., & de Zeeuw, D. (2003) · Kidney International · doi:10.1046/j.1523-1755.2003.00762.x · Cited by 234
Real-time three-dimensional echocardiography for rheumatic mitral valve stenosis evaluation
Zamorano, J., Cordeiro, P., Sugeng, L., Perez de Isla, L., Weinert, L., Macaya, C., Rodríguez, E., & Lang, R. M. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.01.046 · Cited by 230
Sniff nasal inspiratory pressure. A noninvasive assessment of inspiratory muscle strength.
Héritier, F., Rahm, F., Pasche, P., & Fitting, J. W. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.150.6.7952632 · Cited by 235
Validation of biomarkers of food intake—critical assessment of candidate biomarkers
Dragsted, L. O., Gao, Q., Scalbert, A., Vergères, G., Kolehmainen, M., Manach, C., Brennan, L., Afman, L. A., Wishart, D. S., Andres Lacueva, C., et al. (2018) · Genes & Nutrition · doi:10.1186/s12263-018-0603-9 · Cited by 230
Repeatability of Multiparametric Prostate MRI Radiomics Features
Schwier, M., van Griethuysen, J., Vangel, M. G., Pieper, S., Peled, S., Tempany, C., Aerts, H. J. W. L., Kikinis, R., Fennessy, F. M., & Fedorov, A. (2019) · Scientific Reports · doi:10.1038/s41598-019-45766-z · Cited by 237
Jiang, C., Zhang, L., Yang, Q., Huang, S., Shi, H., Long, Q., Qian, B., Liu, Z., Guan, Q., Liu, M., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-24680-x · Cited by 230
Fuller, N. J., Laskey, M. A., & Elia, M. (1992) · Clinical Physiology · doi:10.1111/j.1475-097x.1992.tb00831.x · Cited by 236
Bosy-Westphal, A., Jensen, B., Braun, W., Pourhassan, M., Gallagher, D., & Müller, M. J. (2017) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2017.27 · Cited by 231
Vessel enhancing diffusionA scale space representation of vessel structures
MANNIESING, R., VIERGEVER, M., & NIESSEN, W. (2006) · Medical Image Analysis · doi:10.1016/j.media.2006.06.003 · Cited by 232
Rodrigues, J. A., Hug, I., Diniz, M. B., & Lussi, A. (2008) · Caries Research · doi:10.1159/000148162 · Cited by 233
Pinsault, N., & Vuillerme, N. (2009) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.08.003 · Cited by 234
Watson, A. C., Hughes, P. D., Louise Harris, M., Hart, N., Ware, R. J., Wendon, J., Green, M., & Moxham, J. (2001) · Critical Care Medicine · doi:10.1097/00003246-200107000-00005 · Cited by 234
McDannold, N., Tempany, C. M., Fennessy, F. M., So, M. J., Rybicki, F. J., Stewart, E. A., Jolesz, F. A., & Hynynen, K. (2006) · Radiology · doi:10.1148/radiol.2401050717 · Cited by 231
Reliability of four scales on balance disorders in persons with multiple sclerosis
Cattaneo, D., Jonsdottir, J., & Repetti, S. (2007) · Disability and Rehabilitation · doi:10.1080/09638280701191859 · Cited by 229
Estimation of V?O2max from the ratio between HRmax and HRrest ? the Heart Rate Ratio Method
Uth, N., S�rensen, H., Overgaard, K., & Pedersen, P. K. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-003-0988-y · Cited by 225
Giusca, S., Dambrauskaite, V, Scheurwegs, C., D'hooge, J., Claus, P., Herbots, L., Magro, M., Rademakers, F., Meyns, B., Delcroix, M., et al. (2010) · Heart · doi:10.1136/hrt.2009.171728 · Cited by 230
Herrera, E., Sandoval, M. C., Camargo, D. M., & Salvini, T. F. (2010) · Physical Therapy · doi:10.2522/ptj.20090131 · Cited by 230
The ICS‐‘BPH’ Study: uroflowmetry, lower urinary tract symptoms and bladder outlet obstruction
Reynard, Yang, Donovan, Peters, Schafer, Rosette, D. L., Dabhoiwala, Osawa, Lim, T. L., & Abrams (1998) · British Journal of Urology · doi:10.1046/j.1464-410x.1998.00813.x · Cited by 234
Czerniec, S. A., Ward, L. C., Refshauge, K. M., Beith, J., Lee, M. J., York, S., & Kilbreath, S. L. (2010) · Cancer Investigation · doi:10.3109/07357900902918494 · Cited by 233
Mani, S., Sharma, S., Omar, B., Paungmali, A., & Joseph, L. (2017) · Journal of Telemedicine and Telecare · doi:10.1177/1357633x16642369 · Cited by 226
Yamamuro, M., Tadamura, E., Kubo, S., Toyoda, H., Nishina, T., Ohba, M., Hosokawa, R., Kimura, T., Tamaki, N., Komeda, M., et al. (2005) · Radiology · doi:10.1148/radiol.2342031271 · Cited by 233
Livingstone, M., Prentice, A., Coward, W., Ceesay, S., Strain, J., McKenna, P., Nevin, G., Barker, M., & Hickey, R. (1990) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/52.1.59 · Cited by 231
Detection of anaemia from retinal fundus images via deep learning
Mitani, A., Huang, A., Venugopalan, S., Corrado, G. S., Peng, L., Webster, D. R., Hammel, N., Liu, Y., & Varadarajan, A. V. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0487-z · Cited by 230
Raman, S. V., Shah, M., McCarthy, B., Garcia, A., & Ferketich, A. K. (2006) · American Heart Journal · doi:10.1016/j.ahj.2005.04.029 · Cited by 229
Palmer, C. D., Lewis, M. E., Geraghty, C. M., Barbosa, F., & Parsons, P. J. (2006) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2006.09.001 · Cited by 232
Comparison of Three Methods of Measuring Corneal Thickness and Anterior Chamber Depth
Buehl, W., Stojanac, D., Sacu, S., Drexler, W., & Findl, O. (2006) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2005.08.048 · Cited by 229
Early management of proximal humeral fractures with hemiarthroplasty
Kontakis, G. M., Koutras, C., Tosounidis, T. H., & Giannoudis, P. V. (2008) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.90b11.21070 · Cited by 230
van Elst, L. T., Woermann, F. G., Lemieux, L., Thompson, P. J., & Trimble, M. R. (2000) · Brain · doi:10.1093/brain/123.2.234 · Cited by 230
Castellano, J., Alvarez-Pastor, D., & Bradley, P. S. (2014) · Sports Medicine · doi:10.1007/s40279-014-0144-3 · Cited by 226
Measures of Reliability in Sports Medicine and Science: Correspondence
Atkinson, G., & Nevill, A. (2000) · Sports Medicine · doi:10.2165/00007256-200030050-00005 · Cited by 226
(1999) · PubMed · Cited by 230
Ventilation and hypoxic ventilatory response of Tibetan and Aymara high altitude natives
Beall, C. M., Strohl, K. P., Blangero, J., Williams‐Blangero, S., Almasy, L. A., Decker, M. J., Worthman, C. M., Goldstein, M. C., Vargas, E., Villena, M., et al. (1997) · American Journal of Physical Anthropology · doi:10.1002/(sici)1096-8644(199712)104:4<427::aid-ajpa1>3.0.co;2-p · Cited by 230
Hong, Y. J., Lee, H., Kim, J., Lee, M., Choi, H. J., Hyeon, T., & Kim, D. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201805754 · Cited by 229
Miller, W. C., Deathe, A. B., & Speechley, M. (2003) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(02)04807-4 · Cited by 232
Sopher, A. B., Thornton, J. C., Wang, J., Pierson, R. N., Heymsfield, S. B., & Horlick, M. (2004) · Pediatrics · doi:10.1542/peds.113.5.1285 · Cited by 228
Kwee, T. C., Takahara, T., Koh, D., Nievelstein, R. A. J., & Luijten, P. R. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21569 · Cited by 229
Development and Validation of a Short Global Dry Eye Symptom Index
Schaumberg, D. A., Gulati, A., Mathers, W. D., Clinch, T., Lemp, M. A., Nelson, J. D., Foulks, G. N., & Dana, R. (2007) · The Ocular Surface · doi:10.1016/s1542-0124(12)70053-8 · Cited by 230
A modified formula for calculating low-density lipoprotein cholesterol values
Chen, Y., Zhang, X., Pan, B., Jin, X., Yao, H., Chen, B., Zou, Y., Ge, J., & Chen, H. (2010) · Lipids in Health and Disease · doi:10.1186/1476-511x-9-52 · Cited by 230
Defining a Patient-Reported Outcome Measure for Urethral Stricture Surgery
Jackson, M. J., Sciberras, J., Mangera, A., Brett, A., Watkin, N., N'Dow, J. M. O., Chapple, C. R., Andrich, D. E., Pickard, R. S., & Mundy, A. R. (2011) · European Urology · doi:10.1016/j.eururo.2011.03.003 · Cited by 229
Reliability of the Melbourne Assessment of Unilateral Upper Limb Function
Randall, M., Carlin, J. B., Chondros, P., & Reddihough, D. (2001) · Developmental Medicine and Child Neurology · doi:10.1017/s0012162201001396 · Cited by 232
Validation in Volunteers of a Near-Infrared Spectroscope for Monitoring Brain Oxygenation In Vivo
Pollard, V., Prough, D. S., DeMelo, A. E., Deyo, D. J., Uchida, T., & Stoddart, H. F. (1996) · Anesthesia & Analgesia · doi:10.1097/00000539-199602000-00010 · Cited by 225
Padulo, J., Oliva, F., Frizziero, A., & Maffulli, N. (2013) · PubMed · doi:10.11138/mltj/2013.3.4.250 · Cited by 239
Salivary cortisol reflects serum cortisol: analysis of circadian profiles.
Dorn, L. D., Lucke, J. F., Loucks, T. L., & Berga, S. L. (2007) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/000456307780480954 · Cited by 228
Rodríguez, G., Moreno, L. A., Blay, M. G., Blay, V. A., Fleta, J., Sarría, A., Bueno, M., & the AVENA-Zaragoza Study Group (2005) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602226 · Cited by 228
Assessing Body Composition among 3‐ to 8‐Year‐Old Children: Anthropometry, BIA, and DXA
Eisenmann, J. C., Heelan, K. A., & Welk, G. J. (2004) · Obesity Research · doi:10.1038/oby.2004.203 · Cited by 231
The Validity of Bioelectrical Impedance Models in Clinical Populations
Buchholz, A. C., Bartok, C., & Schoeller, D. A. (2004) · Nutrition in Clinical Practice · doi:10.1177/0115426504019005433 · Cited by 229
Sinha, A., Hollingsworth, K. G., Ball, S., & Cheetham, T. (2013) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2012-3592 · Cited by 226
Quantification of left ventricular trabeculae using fractal analysis
Captur, G., Muthurangu, V., Cook, C., Flett, A. S., Wilson, R., Barison, A., Sado, D. M., Anderson, S., McKenna, W. J., Mohun, T. J., et al. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-36 · Cited by 229
Revisiting the relation between change and initial value: a review and evaluation
Tu, Y., & Gilthorpe, M. S. (2007) · Statistics in Medicine · doi:10.1002/sim.2538 · Cited by 215
Meltzer, L. J., Hiruma, L. S., Avis, K., Montgomery-Downs, H., & Valentin, J. (2015) · Sleep · doi:10.5665/sleep.4918 · Cited by 228
Obesity associated with increased brain age from midlife
Ronan, L., Alexander-Bloch, A. F., Wagstyl, K., Farooqi, S., Brayne, C., Tyler, L. K., & Fletcher, P. C. (2016) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2016.07.010 · Cited by 229
Nielsen, K. G., & Bisgaard, H. F. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.4.2006119 · Cited by 228
A Primer on the Use of Equivalence Testing for Evaluating Measurement Agreement
DIXON, P. M., SAINT-MAURICE, P. F., KIM, Y., HIBBING, P., BAI, Y., & WELK, G. J. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001481 · Cited by 227
Snakes based segmentation of the common carotid artery intima media
Loizou, C. P., Pattichis, C. S., Pantziaris, M., Tyllis, T., & Nicolaides, A. (2007) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-006-0140-3 · Cited by 227
O'Donoghue, M. F., Duncan, J. S., & Sander, J. W. A. S. (1996) · Epilepsia · doi:10.1111/j.1528-1157.1996.tb00610.x · Cited by 223
Hundley, W. G., Li, H. F., Willard, J. E., Landau, C., Lange, R. A., Meshack, B. M., Hillis, L. D., & Peshock, R. M. (1995) · Circulation · doi:10.1161/01.cir.92.5.1151 · Cited by 229
de Bekker-Grob, E. W., Hol, L., Donkers, B., van Dam, L., Habbema, J. D. F., van Leerdam, M. E., Kuipers, E. J., Essink-Bot, M.-L., & Steyerberg, E. W. (2010) · Value in Health · doi:10.1111/j.1524-4733.2009.00670.x · Cited by 224
Cytofluorometric methods for assessing absolute numbers of cell subsets in blood
Brando, B., Barnett, D., Janossy, G., Mandy, F., Autran, B., Rothe, G., Scarpati, B., D'Avanzo, G., D'Hautcourt, J.-L., Lenkei, R., et al. (2000) · Cytometry · doi:10.1002/1097-0320(20001215)42:6<327::aid-cyto1000>3.0.co;2-f · Cited by 231
Buechel, E. V., Kaiser, T., Jackson, C., Schmitz, A., & Kellenberger, C. J. (2009) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-11-19 · Cited by 228
Roebroeck, M. E., Harlaar, J., & Lankhorst, G. J. (1993) · Physical Therapy · doi:10.1093/ptj/73.6.386 · Cited by 228
Cuff-Less and Continuous Blood Pressure Monitoring: A Methodological Review
Sharma, M., Barbosa, K., Ho, V., Griggs, D., Ghirmai, T., Krishnan, S., Hsiai, T., Chiao, J.-C., & Cao, H. (2017) · Technologies · doi:10.3390/technologies5020021 · Cited by 226
Moke, P. S., Turpin, A. H., Beck, R. W., Holmes, J. M., Repka, M. X., Birch, E. E., Hertle, R. W., Kraker, R. T., Miller, J. M., & Johnson, C. A. (2001) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(01)01256-9 · Cited by 225
A review of signals used in sleep analysis
Roebuck, A., Monasterio, V, Gederi, E., Osipov, M., Behar, J., Malhotra, A., Penzel, T., & Clifford, G. D. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/1/r1 · Cited by 223
Vajkoczy, P., Roth, H., Horn, P., Lucke, T., Thomé, C., Hubner, U., Martin, G. T., Zappletal, C., Klar, E., Schilling, L., et al. (2000) · Journal of Neurosurgery · doi:10.3171/jns.2000.93.2.0265 · Cited by 229
Reproducibility of three‐dimensional ultrasound diagnosis of congenital uterine anomalies
Salim, R., Woelfer, B., Backos, M., Regan, L., & Jurkovic, D. (2003) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.127 · Cited by 228
Little, S. A. (2002) · Thorax · doi:10.1136/thorax.57.3.247 · Cited by 230
Multicenter Evaluation of Noninvasive Cardiac Output Measurement by Bioreactance Technique
Raval, N. Y., Squara, P., Cleman, M., Yalamanchili, K., Winklmaier, M., & Burkhoff, D. (2008) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-008-9112-5 · Cited by 229
Continuous Monitoring of Vital Signs Using Wearable Devices on the General Ward: Pilot Study
Weenk, M., van Goor, H., Frietman, B., Engelen, L. J., van Laarhoven, C. J., Smit, J., Bredie, S. J., & van de Belt, T. H. (2017) · JMIR mHealth and uHealth · doi:10.2196/mhealth.7208 · Cited by 223
Accuracy of dual-energy x-ray absorptiometry for body-composition measurements in children
Ellis, K., Shypailo, R., Pratt, J., & Pond, W. (1994) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/60.5.660 · Cited by 229
Ultrasound control for presumed difficult epidural puncture
Grau, T., Leipold, R. W., Conradi, R., & Martin, E. (2001) · Acta Anaesthesiologica Scandinavica · doi:10.1034/j.1399-6576.2001.045006766.x · Cited by 225
Risum, N., Ali, S., Olsen, N. T., Jons, C., Khouri, M. G., Lauridsen, T. K., Samad, Z., Velazquez, E. J., Sogaard, P., & Kisslo, J. (2012) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2012.08.007 · Cited by 225
Dual-Energy X-Ray Absorptiometry Is a Valid Tool for Assessing Skeletal Muscle Mass in Older Women ,
Chen, Z., Wang, Z., Lohman, T., Heymsfield, S. B., Outwater, E., Nicholas, J. S., Bassford, T., LaCroix, A., Sherrill, D., Punyanitya, M., et al. (2007) · The Journal of Nutrition · doi:10.1093/jn/137.12.2775 · Cited by 231
Rosenow, T., Oudraad, M. C. J., Murray, C. P., Turkovic, L., Kuo, W., de Bruijne, M., Ranganathan, S. C., Tiddens, H. A. W. M., & Stick, S. M. (2015) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201501-0061oc · Cited by 226
Wondergem, M., Smits, M. L. J., Elschot, M., de Jong, H. W. A. M., Verkooijen, H. M., van den Bosch, M. A. A. J., Nijsen, J. F. W., & Lam, M. G. E. H. (2013) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.117614 · Cited by 224
Circulating tumor cells in small-cell lung cancer: a predictive and prognostic factor
Hiltermann, T. J. N., Pore, M. M., van den Berg, A., Timens, W., Boezen, H. M., Liesker, J. J. W., Schouwink, J. H., Wijnands, W. J. A., Kerner, G. S. M. A., Kruyt, F. A. E., et al. (2012) · Annals of Oncology · doi:10.1093/annonc/mds138 · Cited by 224
Hernando, D., Roca, S., Sancho, J., Alesanco, Á., & Bailón, R. (2018) · Sensors · doi:10.3390/s18082619 · Cited by 222
Validity of Activity-Based Devices to Estimate Sleep
Weiss, A. R., Johnson, N. L., Berger, N. A., & Redline, S. (2010) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27874 · Cited by 225
Burkhart, T. A., Andrews, D. M., & Dunning, C. E. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.03.022 · Cited by 222
Karlsson, A. C., Martin, J. N., Younger, S. R., Bredt, B. M., Epling, L., Ronquillo, R., Varma, A., Deeks, S. G., McCune, J. M., Nixon, D. F., et al. (2003) · Journal of Immunological Methods · doi:10.1016/j.jim.2003.09.001 · Cited by 223
Scott, P., DiBiase, A. T., Sherriff, M., & Cobourne, M. T. (2008) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2008.04.018 · Cited by 218
Watson, J. F., Collins, C. E., Sibbritt, D. W., Dibley, M. J., & Garg, M. L. (2009) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-6-62 · Cited by 226
Performance of an Automated Polysomnography Scoring System Versus Computer-Assisted Manual Scoring
Malhotra, A., Younes, M., Kuna, S. T., Benca, R., Kushida, C. A., Walsh, J., Hanlon, A., Staley, B., Pack, A. I., & Pien, G. W. (2013) · Sleep · doi:10.5665/sleep.2548 · Cited by 222
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.